Abstract
Tunnel lighting systems serving pedestrian and vehicular traffic must simultaneously satisfy visual performance requirements and energy efficiency constraints. This study investigates the optimization of tunnel lighting design using a sustainable engineering approach based on Response Surface Methodology (RSM) and Specific Lighting Energy Consumption (SLEC). Software-assisted lighting simulations were performed for two tunnel geometries—straight and double-curved—and horizontal (Eh) and vertical (Ev) illuminance levels were evaluated at five representative locations. The resulting data were used to construct RSM-based predictive models and to assess energy performance through SLEC. The effects of mounting height, luminaire spacing, luminous flux, number of luminaires, and tunnel type were systematically analyzed. The results demonstrate that luminaire spacing is the dominant parameter influencing illuminance levels and energy consumption. An optimal configuration consisting of a 12 m luminaire spacing, 5 m mounting height, and 10,000–12,000 lm luminous flux achieved a favorable balance between lighting quality and energy efficiency. Additionally, straight tunnels exhibited higher illuminance uniformity at shorter spacings, whereas curved tunnels showed improved performance under wider spacing conditions. The proposed RSM–SLEC framework provides a robust, data-driven methodology for sustainable tunnel lighting design without compromising safety or visual comfort.
1. Introduction
Advances in Sustainable Engineering Systems have led researchers to explore innovative approaches that balance performance with environmental responsibility. Among these, tunnel lighting has emerged as a critical field where energy consumption, operational costs, and visual quality intersect. Recent studies emphasize that lighting systems are not only technical necessities but also significant contributors to a tunnel’s overall energy profile. Understanding how to reduce energy demand without compromising safety and comfort has become a cornerstone of modern tunnel design.
Tunnel lighting systems play a vital role in ensuring safe and efficient traffic flow. However, their energy consumption presents a significant challenge, especially in large-scale infrastructure projects. Traditional discharge lamps, with their high power demands, have highlighted the need for more sustainable solutions in modern designs. The advancement of LED technology and the implementation of adaptive control systems offer innovative methods that can enhance both energy efficiency and visual comfort. These approaches not only reduce energy usage but also contribute meaningfully to environmental sustainability goals [1]. As such, evaluating and optimizing energy consumption has become essential for the development of resilient infrastructure.
In tunnel lighting design, while luminaire density, tunnel height, and luminaire power are fundamental variables, parameters such as surface reflections can also affect the results in practice. Surface roughness, humidity, material aging, contamination, mounting tolerances, multiple reflections, shading effects of structural elements, and luminaire orientation errors, which are not considered in calculations but are present in real applications, affect light distribution and consequently the illumination levels. For these reasons, even if standard data is obtained in lighting designs by changing luminaire spacing, mounting height, and power values, there may be differences between these values and the actual results.
Modern technologies aim to address these challenges by incorporating energy-saving lighting products, such as LED-based systems. Technical standards and reports also provide critical guidance in this direction. For instance, the IES (2014) RP-22-14 report presents recommendations for energy-conscious lighting applications, while the CIE (2017) outlines detailed directives to improve efficiency [2,3,4]. Hao, Li, and Liu (2015) explored optimization strategies for LED systems, highlighting their potential for significant energy savings and practical implementation in tunnel environments [5]. Lindkvist and Jägerbrand (2019) analyzed adaptive control systems and demonstrated that dynamically adjusting light levels can effectively reduce energy use while preserving visual comfort for drivers [6]. Becchio, Bottero, and Corgnati (2016) emphasized cost-effective and efficient lighting solutions for urban tunnels, proposing a balance between energy savings and infrastructure investment [7].
In a case study from Turkey, Güven and Akdağ (2021) [8] evaluated a smart lighting control system in a tunnel and reported considerable reductions in energy consumption. Similarly, Zhou and Wu (2020) discussed the benefits of intelligent LED systems, focusing on their long-term efficiency and innovation potential [8,9].
Kumar (2018) assessed the impact of dynamic lighting control strategies on energy performance, while Wang (2020) compared traditional lighting systems with LEDs, revealing the superior efficiency of LED solutions [10,11]. Boyce (2014) offered insights into how lighting design can be tailored to human perception, linking visual comfort with efficient energy use [12]. Overall, energy optimization in tunnel lighting holds immense promise, not only through technological advancement but also by aligning with broader sustainability targets. Despite growing focus on LED implementation and adaptive systems, wider global adoption of relevant standards remains necessary. Future efforts should also consider environmental conditions and tunnel types in the design of energy-efficient systems.
The literature also addresses broader factors affecting tunnel lighting and safety. Zhang and Wu (2023) linked mobile phone use among young drivers with risky behaviors such as abrupt braking and acceleration, suggesting that better lighting could mitigate these risks [13]. Kaya and Aydın (2020) studied how luminaire angles influence lighting performance, concluding that certain angles improve light distribution and energy savings [14]. Li and Chen (2020) introduced a vehicle-following lighting control system that reduces energy use while enhancing driver experience through grouped lighting management [15]. Meanwhile, Smith and Brown (2012) found that increased lighting does not always correspond to lower crime rates, emphasizing the importance of contextual factors [16]. Lindkvist and Jägerbrand (2016) examined how crash severity on signalized arterials is influenced by traffic volume, speed, and road geometry, rather than lighting alone [17]. Wang and Xu (2021) evaluated daylight-responsive and time-based control strategies, demonstrating their effectiveness in reducing power consumption in tunnel lighting systems [18]. A summary of these studies is presented in Table 1. In this context, the literature offers valuable insights into strategies for optimizing lighting energy use, improving performance, and guiding infrastructure decisions toward greater sustainability.
Table 1.
Summary of topic.
Strategies developed to reduce energy consumption and enhance driver safety in tunnel lighting have become increasingly practical thanks to recent technological advancements. In particular, LED technologies and adaptive control systems aim to minimize energy usage while maximizing lighting performance. However, the interaction between various parameters within different tunnel geometries plays a significant role in determining overall energy efficiency. The literature provides both theoretical and experimental frameworks to better understand these interactions. In this context, the present study aims to explore, in detail, how variables such as mounting height, spacing between luminaires, luminous flux, and power consumption affect tunnel lighting performance.
Energy optimization has become a central topic of research across many fields in recent years, especially within the manufacturing sector [18]. This study focuses on optimizing energy usage in existing tunnel lighting systems through parametric analysis, with the goal of achieving both efficiency and uniform light distribution. In the experimental design, variables such as mounting height, luminaire spacing, luminous flux, number of fixtures, and power consumption are examined in terms of their impact on horizontal and vertical illumination at various points in the tunnel (e.g., points A, B, C). While existing literature provides a solid foundation in terms of energy efficiency and visual comfort, this research aims to offer a unique contribution by focusing on different tunnel geometries and parameter combinations. In doing so, it adopts an applied approach that integrates adaptive control systems with LED technology to enhance energy efficiency in a real-world context.
2. Special Lighting Electricity Consumption (SLEC)
The physical and mathematical equations used in lighting define the fundamental parameters for illumination homogeneity, light distribution, and energy consumption. Below, these equations are presented with their explanations.
- Ev: Vertical illuminance level (lux).
- Eh: Horizontal illuminance level (lux)
- θ: The angle of incidence of light
- d: Distance from source to surface (meters)
- I: Luminous intensity in the direction of interest (candela)
Equations (4) and (5) describe the lighting levels for the distribution of luminous flux from a point source over a spherical surface, following the inverse square law. However, stadium floodlights are directional sources rather than point sources, so additional corrections for beam angle and light distribution should be considered [18].
U1 and U2 (Homogeneity Ratios): Evaluates the distribution of illumination on the surface. High U1 and U2 values increase visual quality. Higher homogeneity values indicate better lighting uniformity, reducing shadows and improving visual comfort.
Equation (7) accounts for real power consumption over time, which is essential for accurately assessing energy usage in dynamic lighting systems.
- Etotal: Total energy consumption (kWh)
- V: Voltage (constant, in volts)
- cos∅: Power factor (a fixed value between 0 and 1)
- I(t): Current as a function of time (amperes)
- q1 − q2: Time interval (hours, minutes, or seconds)
Equation (8) accounts for real power consumption over time, which is essential for accurately assessing energy usage in dynamic lighting systems.
- SLEC: Special Lighting Electricity Consumption (W/lux)
- η: Fixture efficiency factor
Besides, Equation (8) corrects the denominator from the original formulation by replacing sin (θ) with a more appropriate fixture efficiency factor η, which accounts for real-world optical losses and beam dispersion.
3. Materials and Methods
In this study, daylight-type LED luminaires with wattages of 80, 100, and 120 W and a light efficiency of 100 lumens/W are considered, provided that the luminaire type and light distribution curve are the same. Here, since light distribution is not a variable considered, the light distribution curve in Figure 1 is used for all calculations. The blue line in the figure represents the distribution curve formed by the light intensity (Icd) values oriented at different angles from the armature used in the calculations. Similarly, the data on lighting color and color rendering index were not considered in the study and are therefore not available as data. Both the selection of light intensity (Icd) values based on geometric dimensions and the calculation of illumination levels are performed using the software developed for this study, which is provided in Appendix A. The geometries originally drawn for the tunnel lighting calculation methods developed during the 2018–2019 period are shown in Figure 2. Here, these geometries that include both straight and curved tunnel structures are considered [18,19].
Figure 1.
The armature used and the light distribution curve.
Figure 2.
Sketch of tunnel types.
In this study, the horizontal and vertical illumination levels at points A, B, C, D, E anf F inside the tunnel for each experiment are calculated, taking into account all the luminaires considered in the experiment. These calculations consider the values of power/luminous flux of all armatures and the varying light intensity values (Icd) for points A, B, C, D, E and F, depending on their positions and the geometric dimensions used.
In other words, the calculated illumination levels at points A, B, C, D, E, and F vary depending on the locations of these points, as well as the geometric structure of the tunnel and the luminaires. The locations of points A, B, C, D, E, and F also affect the illumination levels at these points, resulting in low illumination levels at points A, C, and F in a straight (Type 1) tunnel structure. The heights, placement densities, and luminescent fluxes of the luminaires are also parameters that directly affect the illumination levels at points A, B, C, D, E and F. Armatures affect lighting levels through luminous flux values that vary according to their power ratings, and light intensity values that depend on the direction of the light.
This study employed Response Surface Methodology (RSM) to optimize tunnel lighting performance and energy efficiency. RSM is a powerful statistical technique used to evaluate the effects of multiple independent variables on a target response and to identify optimal operating conditions [20,21,22]. By combining experimental design with mathematical modeling, RSM allows for the analysis of both linear and non-linear system behavior through surface plots. The method is widely applied in engineering, particularly in enhancing energy-related processes and improving system performance [23].
In this study, RSM was integrated with sensitivity analysis. Introduced by Morris and Sobol in the 1960s, sensitivity analysis assesses the influence of individual variables on model outputs, helping to identify the most impactful parameters [24]. The variables considered included height (A), lamp spacing (B), luminous flux (C), number of luminaires, and power consumption (P). Their effects were examined in terms of horizontal (Eh) and vertical (Ev) illuminance levels. The results indicated that lamp spacing had the most substantial impact on lighting intensity, whereas luminous flux was the key driver of energy consumption.
The experimental design defined multiple levels for each independent variable. In the tunnel considered for the calculation, the height (A) was varied at 4, 5, and 6 m; lamp spacing (B) was set at 8.612 m, 12.918 m, and 17.224 m; total luminous flux for the entire tunnel (C) was set at 108,000 lm, 110,000 lm, and 128,000 lm. The number of luminaires ranged between 9, 11, and 16, and power consumption values ranged from 1080 W, 1100 W, and 1280 W for the entire tunnel. Since each luminaire can affect the lighting level at every point where it is calculated, all luminaires within the tunnel are taken into account in every experimental calculation performed. Tests were conducted separately for straight (Type 1) and curved (Type2) tunnel types, allowing the analysis of lighting performance and energy efficiency across different structural configurations. All parameters were tested in various combinations to evaluate their impact on horizontal and vertical lighting behavior (Table 2).
Table 2.
Design of experiment (DOE).
Straight (Type 1) and curved (Type 2) tunnel geometries exhibit distinct characteristics in terms of lighting and energy optimization. One tunnel was chosen to be straight and the other curved, to represent the real-land conditions encountered in the terrain. The tunnel structures considered in this study are simulated example models. In addition to the straight model, two curves were used in the curved model to achieve results close to real-world application models. Considering that lighting calculations for more complex tunnels can be performed in parts and sections, the two tunnel types -straight (Type 1) and curved (Type 2) considered were deemed sufficient for the analyses.
As illustrated in Figure 2, the first schematic shows a straight (Type 1) and curved (Type 2) tunnel layouts, systematically visualized. This tunnel spans a total length of 135 m, with a width of 16 m, and luminaire placements were optimized along this width. Key analysis points labeled A, B, C, D, E, and F were selected to represent different horizontal and vertical regions within the tunnel. These locations play a crucial role in evaluating lighting uniformity and energy use. The black dots indicate luminaire positions, whose placement was carefully examined to assess their impact on lighting distribution.
In contrast, the second schematic presents a curved (Type 2) tunnel structure. Despite maintaining the same 135 m length, the geometry becomes more complex due to the presence of bending radii, denoted as r1 = 22 m and r2 = 15 m. These radii significantly influence the pattern of light distribution throughout the tunnel. Again, points A through F were utilized to assess lighting and energy performance both horizontally and vertically. Black dots again mark luminaire positions, while the dashed lines indicate the path of light. Due to the unique geometry of the curved (Type 2) tunnel, effects on lighting uniformity and energy efficiency differ significantly from the straight (Type 1) tunnel case.
This methodology was supported by a computational model developed in DEV-C++ (https://www.dev-cpp.com/). Initially, a formula was defined for each parameter combination, incorporating the coordinates of lighting points throughout the tunnel. DEV-C++ calculations were performed to determine horizontal (Eh) and vertical (Ev) illuminance levels for each experimental combination. These analyses enabled the identification of optimal parameters using the RSM optimizer, enhancing energy efficiency and ensuring uniform light distribution. The study provided an effective solution for tunnel lighting system design, combining theoretical analysis with software-supported applications.
This C program consists of two main sections, designed to model the lighting layout of a tunnel and calculate illuminance levels (in lux) at specific target points. In the first part, the geometric structure of the tunnel is created. The tunnel is divided into four segments: a straight entrance, a wide left-turning curve, a narrower right-turning curve, and a straight exit. Within each segment, the coordinates of the points where luminaires will be placed are computed. The spacing between these points is fixed (e.g., 9 m), ensuring a consistent lighting arrangement. For the curved sections, the points are calculated along circular arcs to reflect realistic geometry. Additionally, the tunnel’s left and right boundaries are defined by calculating offset positions at selected points, allowing the definition of key target points such as A, B, C, D, E, and F. These points represent positions either on the tunnel floor or on the sidewalls.
In the Section 2, a realistic lighting calculation is performed between the defined luminaires and the target points. The program computes both horizontal illuminance (on surfaces like the floor) and vertical illuminance (on surfaces like walls) for each target location. Since every lamp illuminates each target at a specific angle, both vertical and horizontal components of light are considered based on the incident angle. The inverse-square law is also applied, accounting for the decrease in light intensity with increasing distance. As a result, the total horizontal (Eh) and vertical (Ev) illuminance values are calculated in lux for each target point.
These results are highly valuable for analyzing lighting performance across the tunnel, identifying underlit areas, and planning improvements where necessary. The model offers a practical and effective solution from both an engineering perspective and an urban traffic safety standpoint. Furthermore, the code structure is transparent and flexible, allowing for customization—such as adjusting luminous intensity, luminaire height, or tunnel width—based on project needs.
4. DEV-C++ Results and Discussion
Figure 3 and Figure 4 illustrate the graphical results derived from the simulations conducted for the straight (Type 1) and curved (Type 2) tunnel configurations. Variations in lighting levels across these tunnel types appear to be closely linked to their geometric layout and the distribution pattern of the luminaires. Significant disparities were observed between the horizontal (Eh) and vertical (Ev) illuminance values at points A, B, C, D, E, and F. For instance, in the straight tunnel configuration, Point D recorded the highest readings with Eh = 87.35 lux and Ev = 146.76 lux, while lower values were observed at other locations depending on the experimental setup. To ensure clarity and reproducibility, all experimental results—including minimum, maximum, and average illuminance values (Ehmin, Ehmax, Ehort, Evmin, Evmax, Evort)—are comprehensively presented in Table 3. While Figure 3 and Figure 4 visually demonstrate the distribution patterns along the tunnel nodes, Table 3 provides the complete numerical dataset for all experiments, allowing direct verification of the reported conclusions.
Figure 3.
Straight (Type 1) tunnel calculations.
Figure 4.
Curve tunnel calculations.
Table 3.
Result of the design of experiment (DOE).
In a curved (Type 2) tunnel structure, due to the curves, changes in the distances of the luminaires from points A, B, C, D, E, and F can significantly reduce or increase the calculated illumination levels at these points. For both straight and curved tunnel structures, the illumination level values can be significantly higher at certain points compared to others due to factors such as the location of the point, armature placement density, and light intensities affecting the point. Within this scope, in the straight tunnel structure, for Experiment 7, a horizontal illumination value of 87.356 lux was obtained at point D, while a vertical illumination value of 146.77 lux was obtained. In the curved tunnel structure, for Experiment 16, a horizontal illumination value of 173.32 lux was obtained at point C, while a vertical illumination value of 120.31 lux was obtained at point D. When these increases in values are considered, the rise observed at point D in straight tunnels can be explained primarily by the positional characteristics of the point. In contrast, for curved tunnels, the increases occurring at points C and D must be attributed to the tunnel curvatures and the spacing density of the armatures.
These findings suggest that Point D benefits from a favorable position within the light distribution path, whereas Point C suffers from inadequate light coverage, indicating a disadvantageous placement. When the spacing between luminaires was reduced to 8.612 m, a more uniform light distribution was achieved, resulting in enhanced values for both horizontal and vertical illuminance. The best lighting performance was recorded during Experiment 7, where the tunnel height was set at 6 m, the spacing between fixtures was 8.612 m, and the total number of luminaires used was 9. The system operated at a luminous flux of 108,000 lumens and consumed 1080 watts of power. Under these conditions, the average horizontal illuminance reached 16.9 lux, while the vertical component measured 43.8 lux. A noteworthy aspect of Experiment 7 is its ability to deliver high lighting performance despite modest energy consumption. By contrast, Experiment 1, which utilized 1280 watts, only achieved an average of 14.9 lux in horizontal and 38.2 lux in vertical illuminance. These outcomes clearly demonstrate that Experiment 7 achieved greater lighting efficiency, producing superior results with lower energy input.
In conclusion, the parameters applied in Experiment 7 proved to be the most effective in terms of both lighting performance and energy efficiency for straight (Type 1) tunnel configurations. A shorter spacing between luminaires, increased luminous flux, and a strategically optimized number of fixtures collectively contributed to achieving maximum illuminance levels—particularly at Points D and B. At Point D, the ratio between vertical and horizontal illuminance reached approximately 1.68 lux, confirming this location as the most efficiently lit area in the setup. These findings emphasize once again that proper selection and calibration of system parameters are crucial not only for minimizing energy consumption but also for ensuring uniform lighting distribution. Turning to the results of the curved (Type 2) tunnel configuration, as illustrated in Figure 4, the influence of tunnel geometry on light dispersion becomes significantly more pronounced. A detailed analysis of lighting levels highlights the standout performance of Experiment 16. With a tunnel height of 6 m, a luminaire spacing of 8.612 m, a total of 9 fixtures, 108,000 lumens of luminous flux, and 1080 watts of power consumption, this experiment achieved the highest overall illumination values. In particular, Point D once again stood out by delivering superior results in both components—Eh = 74.65 lux and Ev = 120.3 lux. In contrast, Experiment 15, which employed lower luminous output and wider fixture spacing, recorded the weakest illumination levels: Eh = 16.7 lux, Ev = 36.6 lux. This stark contrast clearly underlines how luminous flux and inter-luminaire distance directly affect the intensity and quality of light distribution within curved (Type 2) tunnel environments.
When analyzing the average values, the horizontal illuminance (Eh) was calculated at 28.4 lux, while the vertical illuminance (Ev) reached 66.2 lux. At Points D, C, and E, the measured values exceeded these averages, primarily due to the effective alignment between the luminous flux and the tunnel’s geometric structure. Among all test cases, Experiment 16 stood out for achieving high lighting performance with low energy consumption, clearly demonstrating the system’s efficiency. In contrast, Experiment 17, which used the same power input (1080 W) but increased the luminaire spacing to 12.918 m, showed a noticeable drop in lighting intensity. The recorded values were Eh = 20.79 lux and Ev = 46.03 lux, highlighting how spacing adversely affects illumination despite identical energy usage. These results underline that the number of fixtures and luminous flux intensity are pivotal in determining lighting performance—even when power consumption remains unchanged. In conclusion, the best overall performance in curved (Type 2) tunnel structures was observed in Experiment 16. Here, the vertical illuminance was approximately 1.61 times higher than the horizontal, indicating a well-balanced relationship between lighting intensity and energy efficiency. The increased average values at Points C, D, and E also confirm how appropriate parameter selection can significantly enhance light distribution across complex tunnel geometries. These findings reinforce the necessity of carefully tuning system parameters to achieve optimal lighting output while minimizing energy use.
5. RSM Results and Discussion
Upon examining the RSM surface graph in Figure 5, a distinct non-linear decline in illuminance levels is observed once the spacing between luminaires (Parameter B) exceeds 12 m. In contrast, maximum illuminance values (Ehmax) exhibit an inverse trend. The highest lighting levels were achieved when the luminaire spacing was set at 12 m, and the luminous flux (Parameter C) reached 120,000 lumens. Furthermore, the data reveal a linear increase in lighting performance with rising luminous flux values. However, the influence of Parameter C (luminous flux) is significantly less impactful than Parameter B (inter-luminaire spacing) on the overall results. When comparing Parameter B (spacing) with Parameter A (height), a similar pattern is initially noticeable. Nevertheless, Parameter A exhibits a unique behavior on the surface plot. Specifically, a mounting height of 5 m emerged as the most effective configuration for maximizing Eh values. The analysis suggests that when luminaire spacing is large, selecting a moderate height is beneficial, whereas closer fixture placement requires increased height to maintain optimal lighting.
Figure 5.
3D Surface graph of Ehmax.
In the surface plot comparing Parameter D (number of luminaires) and Parameter C (luminous flux), both variables demonstrate linear effects on the Ehmax values. Interestingly, the gradient of both parameters on the surface is nearly identical, indicating that changes in either variable impact the lighting performance at almost the same rate. Among all factors, inter-luminaire spacing (Parameter B) was identified as the most influential variable in determining lighting behavior. This prompted further analysis across different tunnel types. The value shown in the graphs in Figure 5, Figure 6, Figure 7 and Figure 8, which is defined as Type 1.5, represents the intermediate value determined by the RSM analyses for the transition from a straight (Type 1) tunnel structure to a curved (Type 2) tunnel structure. In areas where the spacing exceeded 15 m, noticeable variations in lighting levels were observed depending on the tunnel type. Beyond 12 m, the impact of tunnel geometry became more dominant than spacing alone. For instance, with a luminaire spacing of 10 m, the tunnel type was found to influence the results up to three times more than other parameters. In the optimal spacing range of 12–13 m, an Ehmax value of approximately 75 lux was achieved. However, by modifying the tunnel type, this value could reach up to 130 lux. These findings demonstrate that tunnel type 2 yields a more effective light distribution in terms of Ehmax values.
Figure 6.
3D Surface graph of Ehort.
Figure 7.
3D Surface graph of Evmax.
Figure 8.
3D Surface graph of Evort.
According to the surface plot of average horizontal illuminance (Ehort) presented in Figure 6, the trends closely resemble those observed in Ehmax values, though several key differences are noted. Primarily, when luminaire spacing exceeds 13 m, a noticeable decrease in lighting levels occurs. On the other hand, the comparison between mounting height and spacing yields a similar pattern to the Ehmax surface, suggesting that the optimal Ehort is achieved at a height of 5 m and a spacing of 13 m, with the value reaching approximately 40 lux. As the spacing drops below 13 m, the average illuminance also begins to decline, confirming that the ideal luminaire distance lies between 12 and 13 m. The impact of luminous flux on Ehort is significantly less pronounced than that of luminaire spacing. While luminaire count and spacing contribute only marginally to the average illuminance, an increase in luminous flux produces a clearly linear improvement. These findings suggest that rather than increasing the number of fixtures, enhancing the output of each luminaire is a more effective strategy for achieving higher average lighting levels.
One of the most significant deviations between Ehmax and Ehort values emerged when analyzing the tunnel type. Under average spacing conditions, Ehort remained around 34 lux. However, when a curved (Type 2) tunnel was implemented, this figure increased substantially, reaching nearly 53 lux.
Figure 7 presents the results for maximum vertical illuminance (Evmax). As the distance between luminaires (B) increases, the influence of mounting height (A) becomes more pronounced. Conversely, when the spacing is reduced, the impact of height diminishes, though it still remains observable to a certain extent. In regions where luminaire spacing exhibits a non-linear increase, a noticeable decline in Evmax is observed. For instance, when B ≈ 12 m, the height factor reaches its peak influence, resulting in an Evmax value of approximately 80 lux. Furthermore, analyzing the interaction between luminaire spacing and luminous flux (C) reveals that although increasing the flux raises Evmax, the effect is not as significant as that of spacing. Even with C = 120,000 lumens, Evmax can reach up to 120 lux, but once spacing exceeds 14 m, values quickly drop to around 60–70 lux. These findings indicate that luminaire spacing accounts for about 60% of the overall impact on vertical illumination, while luminous flux contributes approximately 40%. When examining the relationship between the number of fixtures (D) and luminous flux (C), the trend reverses. In this case, changes in fixture count contribute 40%, while luminous flux affects Evmax by roughly 60%. Notably, when D = 12 and C = 11,000 lumens, Evmax reaches approximately 88 lux. This highlights the comparable influence of these two variables and suggests that they should be jointly optimized for improved lighting performance.
Regarding tunnel type (E), the data show up to a 25% variation in Evmax across different configurations. For example, in a curved (Type 2) tunnel, the average vertical illumination—normally around 60 lux—drops to nearly 45 lux. Nevertheless, the non-linear influence of luminaire spacing remains more dominant than the tunnel type’s effect. Overall, the combination of B = 12 m, A = 5.5 m, C = 110,000 lumens, and E = Curved (Type 2) tunnel appears to optimize Evmax most effectively. This parameter set not only balances the spacing impact but also enhances the overall efficiency of the tunnel lighting system.
When examining the graphs related to average vertical illuminance (Evort), the influence of both mounting height (A) and luminaire spacing (B) becomes clearly evident. In scenarios where luminaires are placed closer together, the height contributes approximately 10% to the overall average vertical illuminance (Figure 8). For instance, when B = 12 m and A = 5.0 m, Evort is observed to be around 45 lux. However, as the spacing increases, a non-linear rise in vertical illumination—from 30 lux to nearly 50 lux—has been identified. This indicates that luminaire spacing impacts the average vertical lighting level by nearly 50%, making it the most influential parameter in this context. When analyzing the relationship between luminaire spacing and luminous flux (C), it becomes apparent that the impact of luminous flux is relatively modest. For example, even when luminous flux increases from 80,000 lumens to 120,000 lumens, Evort only rises from approximately 35 lux to 50 lux. Nonetheless, the patterns observed for luminous flux and the number of luminaires (D) are consistent with those seen in the maximum vertical illuminance plots, highlighting the need to manage both parameters in a balanced manner. Specifically, when the number of luminaires ranges from 10 to 14, the effect on Evort is limited to about 20%. These insights suggest that to enhance average vertical lighting performance, luminous flux and fixture quantity must be considered together, rather than in isolation.
The effect of tunnel type on average vertical illuminance (Evort) is notably significant. When the spacing between luminaires is small, tunnel geometry can influence lighting outcomes by more than 100%; however, as spacing increases, this effect diminishes to roughly a quarter. For example, with E = 1.0 (straight (Type 1) tunnel) and B = 10 m, Evort is measured at 50 lux, whereas increasing the spacing to 16 m causes the value to drop to around 30 lux. This trend reflects an inverse non-linear relationship, where luminaire spacing begins to outweigh the impact of tunnel geometry. When spacing is reduced, tunnel type becomes a dominant factor; however, at wider intervals, its influence weakens considerably. Therefore, optimizing Evort requires a balanced approach in managing key parameters: luminaire spacing (B), mounting height (A), luminous flux (C), and tunnel type (E). For instance, a combination of B = 12 m, A = 5.0 m, C = 100,000 lumens, and E = 1.0 has shown to produce optimal lighting performance. Meticulous coordination of these values can enhance both lighting quality and energy efficiency. A well-balanced system leads to greater reliability and operational success in tunnel lighting applications.
The analysis of SLEC Eh (Specific Lighting Energy Consumption for horizontal illumination), shown in Figure 9, reveals that mounting height and luminaire spacing significantly impact energy efficiency. As height increases from 4 to 6 m, SLEC Eh drops from 90 lm/W to 60 lm/W, indicating that higher mounting positions reduce energy performance. Similarly, increasing B from 10 to 16 m causes SLEC Eh to decline from 80 lm/W to just 30 lm/W. These findings confirm that luminaire spacing is the most influential factor in energy consumption efficiency. When evaluating the effects of luminous flux (C) and number of luminaires (D), it is observed that increasing luminous output from 80,000 to 120,000 lumens causes SLEC Eh to fall from 70 lm/W to 55 lm/W. This drop confirms that higher flux levels, although improving illumination, negatively impact efficiency. Likewise, raising the number of fixtures from 10 to 14 results in a 10% increase in total energy usage. Hence, flux output and fixture count should be optimized in tandem to maintain energy efficiency.
Figure 9.
3D surface graph of SLEC Eh.
The effect of tunnel geometry (E) is also compelling. While straight (Type 1) tunnels yield an average SLEC Eh of 75 lm/W, curved (Type 2) tunnels may experience values as low as 30 lm/W. This effect is most prominent when luminaire spacing is tight and becomes less significant as spacing increases. In light of these results, optimizing SLEC Eh demands a holistic evaluation of all relevant parameters, including height, spacing, luminous flux, number of fixtures, and tunnel type. A configuration of A = 5.0 m, B = 12 m, C = 100,000 lumens, and E = Straight (Type 1) tunnel has demonstrated the most favorable outcome in terms of energy efficiency. Effectively managing these elements is essential for both reducing consumption and establishing a sustainable tunnel lighting infrastructure.
When examining specific energy consumption values for vertical illuminance, it becomes clear that the effect of mounting height does not follow a strictly linear downward trend (Figure 10). This is especially evident when comparing energy consumption at 5 and 6 m in height. The data suggest that after a certain threshold, the impact of height becomes relatively limited. Although adjusting height can influence energy use, its contribution is noticeably less significant than that of luminaire spacing. In contrast, inter-luminaire distance has a much more pronounced effect on both energy use and lighting efficiency. As the spacing increases, energy consumption decreases; however, this decline is non-linear. Spacing values between 10 and 12 m appear to offer an optimal balance between energy savings and lighting performance. Beyond that range, while energy consumption continues to drop, the quality of illumination significantly deteriorates. This underscores the importance of carefully optimizing luminaire spacing during the design phase.
Figure 10.
3D Surface graph of SLEC Ev.
Increasing luminous flux contributes to reduced energy use and improved lighting efficiency. However, its influence remains more limited compared to luminaire spacing. According to the visual data, luminous flux affects energy consumption by approximately one-third as much as spacing does. For instance, using luminous flux in the range of 100,000 to 120,000 lumens yields well-balanced results in terms of both efficiency and uniform illumination. Still, reducing spacing between fixtures tends to increase energy demand, even when luminous flux remains constant. The effect of fixture count closely mirrors that of luminous flux. Both parameters influence energy use and lighting output in a direct and proportionally equivalent manner.
For example, in lighting levels ranging from 30 to 40 lux, the contributions of fixture quantity and luminous output are clearly observable. This suggests that to achieve optimal efficiency and performance, both variables must be jointly optimized. Lastly, the impact of tunnel type on energy consumption varies depending on luminaire spacing. At shorter intervals, its influence is relatively minimal. However, at distances exceeding 12 m, curved (Type 2) tunnels demonstrate clear advantages in terms of energy efficiency. This reveals that tunnel type should not be viewed solely as a structural consideration, but also as a critical factor in energy optimization.
Figure 11 presents the graphical results obtained from the RSM Optimizer for optimal tunnel lighting conditions. The first plot illustrates the parameter combinations that yield maximum horizontal (Ehort) and vertical (Evort) illuminance. Key variables such as mounting height, luminaire spacing, luminous flux, number of luminaires, and tunnel type were evaluated at various levels. Heights ranged between 4 and 6 m, while spacing varied from 8.612 to 17.224 m. Luminous flux was adjusted between 80,000 and 120,000 lumens, with a fixed luminaire count of 9.
Figure 11.
RSM optimizer results.
When the tunnel type was alternated between Type 1 and Type 2, the maximum calculated horizontal average illuminance (Ehort) reached 61.1213 lux, while the vertical average illuminance (Evort) attained 73.047 lux. Despite these relatively high illumination values, the overall desirability score was calculated as 0. This outcome indicates that maximizing illuminance alone does not necessarily correspond to an optimal solution within the multi-objective optimization framework. The desirability function simultaneously considers multiple criteria, including uniformity and energy-related constraints. Therefore, although higher Ehort values were achieved—primarily due to increased luminaire spacing—the corresponding Evort and associated performance metrics did not improve proportionally, leading to a conflict among optimization objectives. As a result, the parameter combination that maximized average illuminance was not selected as the optimal configuration from a global optimization perspective.
The second plot focuses on optimizing SLEC Eh and SLEC Ev, aiming to balance energy consumption with lighting performance. For this setup, height ranged from 4 to 5.3962 m, while luminaire spacing was fixed at 8.612 m. Luminous flux again spanned from 80,000 to 120,000 lumens, and the tunnel type varied between 1 and 2. The optimization aimed for target values of 14 for SLEC Eh and 13 for SLEC Ev. In both cases, the desirability score was 1, indicating an ideal match between parameters and performance objectives. Notably, while increasing luminous flux kept the desirability stable, a decrease in mounting height led to reduced efficiency. Maintaining luminous flux at 120,000 lumens proved particularly beneficial for minimizing energy use while enhancing illumination quality.
The third plot highlights the optimization of SLEC Ev and Evort, based on fine-tuned parameter combinations. Heights ranged between 4.5332 and 6 m, with spacing limited to a narrower band of 8.612 to 9.777 m. The luminous flux was again varied between 80,000 and 120,000 lumens, with the number of luminaires fixed at 9, and tunnel type switching between 1 and 2. Target values were set at 16 for SLEC Ev and 40 lux for Evort. Both goals yielded a desirability of 1, indicating a well-balanced solution. Interestingly, a slight increase in spacing led to a positive effect on SLEC Ev, but simultaneously had a negative impact on Evort. This suggests that achieving harmony between energy savings and lighting quality requires a joint evaluation of these two metrics.
Figure 12 presents the Probability Plot, offering statistical insights into the linearity and normality of the dataset. An examination of SLEC Ev values reveals a consistent and orderly distribution, closely aligned with a normal distribution pattern. The mean value of 34.88 and a standard deviation of 14.28 indicate a strong internal consistency among the data points. Moreover, the p-value of 0.478 confirms that the dataset fits the theoretical normal distribution model, suggesting that SLEC Ev provides reliable and predictable results. Similarly, the SLEC Eh parameter also demonstrates a distribution in accordance with normality. The mean of 73.47 suggests a tendency toward higher energy efficiency values, while the standard deviation of 46.02 reflects a broader data range.
Figure 12.
Probability plot results.
The p-value of 0.426 reinforces the hypothesis of normal distribution, validating SLEC Eh as a dependable reference point for further analysis. For Evmax, the mean was recorded at 80.29 with a standard deviation of 29.56, indicating a relatively stable range in vertical illuminance values. The p-value of 0.508 further supports the normality of the distribution, establishing Evmax as a trustworthy parameter for analyzing both energy consumption and lighting performance. In the case of Ehmax, a mean of 80.81 and a standard deviation of 53.14 were observed. Although the p-value of 0.059 is slightly lower, it still implies a tendency toward normality. These findings position Ehmax as a meaningful metric for evaluating lighting quality and energy performance. Overall, the results confirm that all examined parameters follow well-structured and analyzable distribution patterns. This statistical reliability enhances the accuracy of the study’s findings and supports design and optimization efforts by providing a solid analytical foundation. Consequently, these metrics offer dependable support for achieving optimized tunnel lighting solutions that balance both energy efficiency and illumination quality.
In addition, Figure 13 visualizes the outcomes of a sensitivity analysis conducted to assess the influence of various tunnel lighting design parameters. The analysis identifies luminaire spacing (B) as the most impactful variable across all evaluated outcomes. It exerts the highest percentage of influence, particularly on critical indicators such as illuminance levels and energy efficiency, surpassing the impact of all other parameters. The number of luminaires (D) also plays a significant role, especially in affecting energy-related outputs like SLEC Eh and SLEC Ev, highlighting its importance in energy optimization strategies. Conversely, factors such as mounting height (A), luminous flux (C), and tunnel type (E) exhibited comparatively lower influence across the evaluated metrics. These findings emphasize the necessity of prioritizing luminaire spacing and quantity during the design and optimization of tunnel lighting systems. Specifically, careful adjustment of the spacing between luminaires proves to be a critical factor in maximizing light distribution while minimizing energy consumption.
Figure 13.
Sensitivity analysis results graph.
In the RSM analysis, Tunnel Type (Parameter E) was treated as a categorical factor and evaluated alongside geometric and photometric variables. The surface plots and sensitivity analysis revealed that, although its individual effect was lower than that of luminaire spacing (B), tunnel geometry significantly influenced illuminance distribution patterns. For instance, Evmax exhibited up to a 25% variation depending on the tunnel configuration, while Evort showed changes exceeding 100% under tight spacing conditions. This demonstrates that tunnel type does not merely act as a structural descriptor but plays a measurable role in modifying light propagation behavior.
Furthermore, interaction effects between Tunnel Type (E) and luminaire spacing (B) were particularly evident. At spacing values below 12 m, geometric differences between straight (Type 1) and curved (Type 2) tunnels produced amplified changes in vertical illumination. However, as spacing increased, the dominance of geometry weakened and spacing became the controlling factor. Sensitivity analysis confirmed that while spacing (B) remained the most influential parameter overall, Tunnel Type (E) contributed significantly to vertical illumination performance and energy-related metrics, particularly under constrained geometric conditions.
6. Conclusions
This study investigated the effects of various design parameters on optimizing energy efficiency and lighting performance in tunnel illumination systems. The findings provide valuable insights into how these parameters should be balanced in both straight (Type 1) and curved (Type 2) tunnel structures.
- -
- Reducing the spacing between luminaires and optimizing mounting height were found to be critical for both energy efficiency and lighting uniformity. A combination of 12–13 m spacing and 5–6 m height delivered the highest lighting performance.
- -
- Increasing the number of luminaires directly influenced energy consumption; however, efficient spatial arrangement allowed energy savings to be preserved. To achieve high performance with minimal power use, luminaires must be positioned strategically.
- -
- In curved (Type 2) tunnels, enhancing luminous flux improved light intensity, with geometry playing a decisive role in amplifying this effect. Notably, a luminaire spacing of 8.612 m and a luminous flux of 120,000 lumens yielded the most favorable outcomes.
- -
- Tunnel type significantly impacted both light distribution and energy performance. Curved (Type 2) tunnels were shown to deliver greater lighting uniformity, particularly when wider luminaire spacing was applied.
- -
- Combining high luminous flux with short luminaire spacing proved effective in minimizing energy use while maximizing lighting quality. Achieving this balance is essential for both energy conservation and visual comfort.
- -
- The Response Surface Methodology (RSM) emerged as a powerful tool for identifying optimal parameter combinations. The analysis revealed that a 12 m luminaire spacing paired with 100,000 lumens of luminous flux provided balanced results in terms of energy consumption and illumination effectiveness.
- -
- Among all variables, luminaire spacing had the most dominant effect on both energy use and lighting performance. Other parameters, such as height, luminous flux, and number of luminaires, had comparatively smaller influences.
- -
- Finally, aligning tunnel geometry with appropriate luminous flux levels and luminaire placements was shown to effectively deliver uniform lighting. This coordination is crucial for enhancing both energy efficiency and user visual comfort.
Author Contributions
Conceptualization, B.Ö.; methodology, B.Ö.; software and theoretical illumination calculations, N.İ. (DEV-C++ program); SLEC theory development and optimization techniques, B.Ö.; formal analysis, B.Ö.; investigation, B.Ö.; writing—original draft preparation, B.Ö.; writing—review and editing, N.İ. and B.Ö.; academic evaluation and interpretation, N.İ. and B.Ö.; supervision, B.Ö. All authors have read and agreed to the published version of the manuscript.
Funding
This research received no external funding.
Data Availability Statement
The data presented in this study are available from the corresponding author upon reasonable request.
Conflicts of Interest
The authors declare no conflict of interest.
Appendix A. C++ Code of SLEC Calculation
Figure A1 presents the C++ program developed to model the tunnel geometry and determine the positions of the lighting armatures, as well as to calculate the horizontal and vertical illuminance levels (Eh and Ev) at selected target points. The program first calculates the tunnel path using straight segments and circular arcs based on predefined geometric parameters. Lamp coordinates are then taken into consideration along this path. Later, using the luminous intensity and mounting height, the program computes the horizontal distance, total distance, and cosine components required for illuminance calculations. Finally, the horizontal and vertical illuminance values at specific points are obtained through iterative evaluation of the contribution of each armature.
Figure A1.
Software used in tunnel lighting calculations.
References
- Özdamar, O.; Öztürk, B. A New Specific Carbon Footprint (Scf) Theory of Flow Rate and Energy Consumption Variations of An Industrial Internal Gear Pump. Int. J. 3D Print. Technol. Digit. Ind. 2024, 8, 428–436. [Google Scholar] [CrossRef] [Scilit]
- IES. Recommended Practice for Tunnel Lighting (RP-22-14); Illuminating Engineering Society: New York, NY, USA, 2014. [Google Scholar]
- CIE. Road Lighting for Major Roads (CIE 115:2017); International Commission on Illumination: Vienna, Austria, 2017. [Google Scholar]
- IES. Lighting for Hospital and Healthcare Facilities. (RP-22-14); Illuminating Engineering Society: New York, NY, USA, 2014. [Google Scholar]
- Hao, J.; Li, Q.; Liu, X. Optimization of LED lighting systems for road tunnels. Energy Build. 2015, 105, 456–464. [Google Scholar]
- Lindkvist, C.; Jägerbrand, A.K. Energy-efficient tunnel lighting using adaptive control systems: A case study. Light. Res. Technol. 2019, 51, 350–363. [Google Scholar]
- Becchio, C.; Bottero, M.C.; Corgnati, S.P. Cost-effective and energy-efficient solutions for tunnel lighting in urban areas. Sustain. Cities Soc. 2016, 21, 88–96. [Google Scholar]
- Güven, C.; Akdağ, Y. Intelligent control systems for tunnel lighting: A case study in Turkey. In Proceedings of the IEEE International Conference on Smart Infrastructure, Virtual, 7–10 September 2021; IEEE: New York, NY, USA, 2021; pp. 123–129. [Google Scholar]
- Zhou, J.; Wu, H. Smart LED systems for energy-efficient tunnel lighting. In Proceedings of the International Symposium on Green Energy, Xi’an, China, 20–22 August 2020; Springer: Berlin/Heidelberg, Germany, 2020; pp. 67–74. [Google Scholar]
- Kumar, R. Dynamic Lighting Control Strategies for Tunnels to Reduce Energy Consumption. Ph.D. Thesis, University of Berlin, Berlin, Germany, 2018. [Google Scholar]
- Wang, T. Comparative Study of LED vs. Traditional Lighting Systems in Tunnels: An Energy Perspective. Master’s Thesis, University of Manchester, Manchester, UK, 2020. [Google Scholar]
- Boyce, P.R. Human Factors in Lighting, 3rd ed.; CRC Press: Boca Raton, FL, USA, 2014. [Google Scholar]
- Zhang, L.; Wu, J. Handheld Cellphone Use and Risky Driving in Adolescents. Accid. Anal. Prev. 2023, 110, 456–467. [Google Scholar] [CrossRef] [Scilit]
- Kaya, H.; Aydın, A. Effects of Luminaire Angle on Illumination Performance in Tunnel Lighting. Balk. J. Electr. Comput. Eng. 2020, 8, 123–135. [Google Scholar] [CrossRef] [Scilit]
- Li, J.; Chen, F. An ‘Illumination Moving with the Vehicle’ Intelligent Control System of Road Tunnel Lighting. Sustainability 2020, 12, 7314. [Google Scholar] [CrossRef] [Scilit]
- Smith, T.; Brown, R. Do We Really Need More Lights? Accid. Anal. Prev. 2012, 45, 210–220. [Google Scholar] [CrossRef] [Scilit]
- Lindkvist, A.; Jägerbrand, A. Examining the Factors Influencing the Injury Severity of Crashes on Arterials with Signal Coordination. J. Transp. Saf. 2016, 12, 256–270. [Google Scholar] [CrossRef] [Scilit]
- Wang, L.; Xu, W. Comparative Study of Energy Savings for Various Control Strategies in the Tunnel Lighting System. Appl. Sci. 2021, 11, 6372. [Google Scholar] [CrossRef] [Scilit]
- Isıyel, Ö.Ö. Kurp eksenli tünellerde koordinat esaslı aydınlatma tasarımı. Master’s Thesis, Bilecik Şeyh Edebali Üniversitesi, Lisansüstü Eğitim Enstitüsü, Bilecik, Turkey, 2023. [Google Scholar]
- Savaş, A.F.; Öktem, H.; Öztürk, B.; Uygur, İ.; Küçük, Ö. Energy consumption, mechanical and metallographic properties of cryogenically treated tool steels. Open Chem. 2023, 21, 20220322. [Google Scholar] [CrossRef] [Scilit]
- Szwemin, P.; Fiebig, W. The Influence of Radial and Axial Gaps on Volumetric Efficiency of External Gear Pumps. Energies 2021, 14, 4468. [Google Scholar] [CrossRef] [Scilit]
- Golbaz, S.; Nabizadeh, R.; Rafiee, M.; Yousefi, M. Comparative study of RSM and ANN for multiple target optimisation in coagulation/precipitation process of contaminated waters: Mechanism and theory. Int. J. Environ. Anal. Chem. 2022, 102, 8519–8537. [Google Scholar] [CrossRef] [Scilit]
- Veza, I.; Spraggon, M.; Fattah, I.R.; Idris, M. Response surface methodology (RSM) for optimizing engine performance and emissions fueled with biofuel: Review of RSM for sustainability energy transition. Results Eng. 2023, 18, 101213. [Google Scholar] [CrossRef] [Scilit]
- Bellotti, D.; Cassettari, L.; Mosca, M.; Magistri, L. RSM approach for stochastic sensitivity analysis of the economic sustainability of a methanol production plant using renewable energy sources. J. Clean. Prod. 2019, 240, 117947. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |