Skip to Content
WaterWater
  • Correction
  • Open Access

12 February 2026

4 Pages

Correction: Zhou, X.; Liu, Y. Deciphering Relative Sea-Level Change in Chesapeake Bay: Impact of Global Mean, Regional Variation, and Local Land Subsidence, Part 2: Results. Water 2025, 17, 3235

and
Department of Civil & Environmental Engineering, Morgan State University, Baltimore, MD 21251, USA
*
Author to whom correspondence should be addressed.
In the original publication [1], there was a mistake in Table 1 as published.
In Table 1, Row 14 and Column 5, change “2.71” to “2.49”. This is because (Column 4–Column 5) must equal 1.10. However, for Tolchester Beach, (3.59 − 2.71) = 0.88, which is not equal to 1.10. This discrepancy allowed us to identify the use of an incorrect value (2.71) for Column 5 at Tolchester Beach. The values for the other 14 tide gauges are correct. During proofreading, we focused mainly on responding to the editor’s questions and correcting grammar, and we did not re-verify the numerical values in Table 1. We apologize for this oversight.
In Table 1, Row 14 and Column 9, change “2.55” to “2.33”. This is because Column 5 minus Column 9 should equal 0.16. The incorrect use of 2.71 above led to the earlier incorrect value 2.55. Using the correct values, 2.49 minus 0.16 gives 2.33, which is accurate. The value 0.50 in Column 8 also confirms this: it equals 2.33 (Column 9) minus 1.83 (Column 7), not 2.55 minus 1.83. This again demonstrates that the earlier use of 2.71 was an error.
In Table 1, Row 18 and Column 5, change “2.64” to “2.63”. The correction of “2.71” to “2.49” in Item 1 requires updating “2.64” to “2.63” for the average of the other 15 values in Column 5.
In Table 1, Row 18 and Column 9, change “2.47” to “2.46”. The correction of “2.55” to “2.33” in Item 2 leads to updating “2.47” to “2.46” for the average of the other 15 values in Column 9.
The corrected Table 1 appears below:
Table 1. Simulation results and comparisons of linear RSLC trends.
Due to the change from 2.55 to 2.33 in Table 1, Row 14 and Column 9 on page 7, the contribution rate of PCS—0.50 mm/year in Column 8—to the total subsidence of 2.33 mm/year in Column 9 should be 21% (=0.50/2.33 × 100). The following correction has been made to Section 4, Paragraph 2:
Estimated primary consolidation subsidence (PCS): Estimated PCS rates of the last 14 TGs are shown in col. 8 of Table 1, excluding TG CBBT where the compaction of aquifer systems is attributed to CIS. According to our approach, PCS values at the 10 TG locations range from 0.26 mm/year at TG Wachapreague, VA, to 0.75 mm/year at TG Lewisetta, VA. The average PCS is 0.38 mm/year during 1900 to 2023. The proportion of PCS relative to the total LS rate at top five locations are as follows: 26% at TG Lewisetta, VA; 24% at Yorktown, VA; 22% at Sewells Point, VA, and Dahlgren, VA; and 21% at TG Tolchester Beach, MD, respectively.
The authors state that the scientific conclusions are unaffected. This correction was approved by the Academic Editor. The original publication has also been updated.

Reference

  1. Zhou, X.; Liu, Y. Deciphering Relative Sea-Level Change in Chesapeake Bay: Impact of Global Mean, Regional Variation, and Local Land Subsidence, Part 2: Results. Water 2025, 17, 3235. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.