Skip to Content
CrystalsCrystals
  • Article
  • Open Access

27 November 2026

17 Pages

Electrodeposition of Copper from a Cu(II)-Betaine/[BMIM][TFSI] Electrolyte and Its Interfacial Behavior in CO2-Saturated Bicarbonate

,
,
and
1
The Scientific Research Institute for New Chemical Technologies and Materials, Al-Farabi Kazakh National University, 96a Tole bi Str., 050012 Almaty, Kazakhstan
2
Satbayev University, 22 Satbayev Str., 050013 Almaty, Kazakhstan
3
Center of Physical Chemical Methods of Research and Analysis, Al-Farabi Kazakh National University, 96a Tole bi Str., 050012 Almaty, Kazakhstan
4
Laboratory of Electrochemical Interfaces and Catalysis, The Scientific Research Institute for New Chemical Technologies and Materials, Al-Farabi Kazakh National University, 96a Tole bi Str., 050012 Almaty, Kazakhstan

Abstract

TFSI-based ionic liquids present promising media for copper electrodeposition; however, the limited solubility of conventional copper salts can impede electrolyte preparation. In this study, a Cu(II)–betaine precursor, [Cu(bet)2][TFSI]2, was synthesized by dissolving CuO in betainium bis(trifluoromethanesulfonyl)imide ([Hbet][TFSI]) and subsequently transferred into 1-butyl-3-methylimidazolium TFSI ([BMIM][TFSI]). This process yielded a homogeneous electrolyte containing 50 mM Cu(II) within 30 min at 30 °C. Cyclic voltammetry identified two cathodic processes corresponding to the sequential reduction of Cu(II)/Cu(I) and Cu(I)/Cu(0). Impedance measurements of the deposition electrolyte necessitated the inclusion of Gerischer and finite-length diffusion elements to accurately describe its electrochemical behavior. The copper electrodes produced were assessed in 0.5 M NaHCO3 under both N2- and CO2-saturated conditions using linear sweep voltammetry (LSV), electrochemical impedance spectroscopy (EIS), and distribution of relaxation times (DRT) analysis. Under CO2 saturation, the polarization resistance at −1.0 V decreased from 643.9 to 309.8 Ω cm2 compared to N2 saturation. Increasing the cathodic potential from −1.0 to −1.4 V resulted in a reduction of the fitted charge-transfer resistance from 309.8 to 12.1 Ω cm2 and shifted the main DRT contributions to higher frequencies. The response to copper deposition charge was non-monotonic: increasing the charge from 20 to 30 mC reduced the impedance contributions, while a further increase to 70 mC led to a slight increase in impedance and altered the relaxation features. These results establish a rapid precursor-transfer method for copper electrodeposition and highlight the effectiveness of EIS–DRT analysis in elucidating changes in the cathodic interfacial response.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.