Human Organoids and Organ-on-Chip for Biotoxin Assessment: Applications, Best Practices, and a Translational Roadmap

,
,
,
and
1
Beijing Key Laboratory of Diagnostic and Traceability Technologies for Food Poisoning, Beijing Center for Disease Control and Prevention, Beijing 100013, China
2
School of Public Health, Capital Medical University, Beijing 100069, China
*
Author to whom correspondence should be addressed.

Abstract

Human organoids and organ-on-chip/microphysiological systems (OoC/MPS) are increasingly used as new-approach methodologies for biotoxin assessment. They retain human-relevant tissue organization and enable interpretable analysis of exposure geometry, barrier transport, perfusion, and (when needed) multi-organ coupling. In this review, we synthesize primary evidence across major toxin classes, including bacterial enterotoxins (e.g., cholera toxin, heat-stable enterotoxins, Shiga toxins), mycotoxins (e.g., aflatoxin B1, ochratoxin A, deoxynivalenol), and algal/cyanobacterial toxins (e.g., saxitoxin, domoic acid, microcystins, biliatresone). We emphasize studies that clearly define toxin identity and exposure context and that demonstrate mechanism-critical model competencies under assay conditions. We highlight decision-informative functional endpoints that align with the dominant pathophysiology. These include cystic fibrosis transmembrane conductance regulator (CFTR)-dependent secretion in human enteroids/colonoids, transporter-linked proximal tubular injury in kidney MPS, gut–kidney axis injury from Shiga toxin-producing E. coli in microfluidic systems, and multi-electrode array (MEA) network readouts in human 3D neural tissues. We then summarize best practices that improve cross-study comparability. These include reporting delivered versus nominal exposure, assessing recovery/mass balance and device/material interactions, applying proportional biological qualification (polarity, transporter/enzymatic competence, functional stability), defining a minimal comparable endpoint core, and preserving QIVIVE readiness in reporting. Finally, we outline near-term priorities for the field, including chronic low-dose and mixture designs, harmonized reference panels and acceptance criteria, and fit-for-purpose escalation to coupled OoC/MPS only when perfusion or organ–organ coupling is expected to change the interpretation.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.