Skip to Content
SustainabilitySustainability
  • Article
  • Open Access

28 November 2026

23 Pages

An Improved Water Quality Index Integrating National-Standard Limit Values and Information Entropy for Groundwater-Quality Evaluation in the West Liaohe Plain

,
,
,
,
,
,
and
1
China Institute of Geo-Environment Monitoring, Beijing 100081, China
2
School of Resources and Environmental Engineering, Hefei University of Technology, Hefei 230009, China
3
Institute of Hydrogeology and Environmental Geology, Chinese Academy of Geological Sciences, Shijiazhuang 050061, China
4
Guangdong Geological Environment Monitoring Station, Guangzhou 510308, China
Sustainability2026, 18(23), 12171;https://doi.org/10.3390/su182312171 
(registering DOI)

Abstract

The equal-weight water quality index assigns the same weight to every indicator, whereas the entropy-weighted water quality index (EWQI) is driven only by observed data. Neither scheme reflects the regulatory priority embedded in the national standard. To overcome this limitation, an improved index is employed. It linearly combines the Class III limit-value weight defined in the Chinese national Standard for Groundwater Quality (GB/T 14848-2017) with the objective information-entropy weight. The method was applied to 88 groundwater samples and 12 routine indicators collected in 2021 from the west Liaohe Plain. All original measurements were retained, and no outlier was removed. The equal-weight, entropy-weighted and improved indices were computed and compared. They were cross-checked against the single-factor index and the Nemerow pollution index (NPI), which emphasizes the maximum single-factor exceedance. Ordinary kriging was then used to map the spatial distribution of water quality. The exceedance rates of manganese, iron, fluoride and the permanganate index (CODMn, a measure of organic load) were 45.5%, 29.5%, 23.9% and 17.0%, respectively. The combined weight assigned the highest value to manganese (0.2548), the most frequently exceeded indicator. This corrects the tendency of pure entropy weights to underweight indicators that have stringent regulatory limits. The improved index classified 22 samples (25.0%) as Class IV or Class V, the two poorest quality grades. By contrast, the entropy-weighted and equal-weight indices identified only three (3.4%) and eight (9.1%) such samples. The NPI ranged from 0.289 to 8.115, and 60.2% of samples showed slight or greater exceedance. Under the national-standard single-factor-veto rule, a sample receives its worst single-indicator grade. Using this rule as the benchmark, the improved index attained a recall of 32.8% for poor-quality water, 2.8 and 7.3 times those of the equal-weight and entropy-weighted schemes. The fact that every index value above the Class III threshold contains an exceedance follows directly from the index definition. It is therefore a mathematical consequence rather than independent validation. Overall, the improved index is better suited to groundwater-quality evaluation and zoned management in areas where geogenic poor quality and anthropogenic pollution coexist.

Article Metrics

Citations

Article Access Statistics

Article metric data becomes available approximately 24 hours after publication online.