Abstract
For a fixed volume of insulation beneath a highway, board thickness and lateral coverage affect different parts of the subgrade. A two-dimensional enthalpy model was used to compare layouts with 1.35 m3 of extruded polystyrene (XPS) and 8.10 m3 of waste-modified soil per longitudinal metre. The narrowest board gave the highest minimum temperatures at the median and inner-lane centre, whereas broader coverage raised the minimum temperature across the traffic lanes. Under the strongest forcing, the lane-band minimum was 4.93 K higher with full-width coverage than with narrow coverage after joint mesh and time-step refinement. At shallow depth, however, the maximum width at subzero temperatures increased from 2.87 to 7.50 m. Where wider boards gave similar minima, their ranking depended on numerical resolution, as did the sign of temperatures close to zero. In the laboratory composite, the XPS–soil interface reached 0 °C after about 7 h, compared with 54.2 h in the fitted model. This delay limits estimates of freezing onset. The root mean square error of 1.71 K was calculated from a later period of the same experiment that was excluded from fitting. Minimum temperature, the width exposed to subzero temperatures, and the duration of exposure at individual locations, thus, give different assessments of the same insulation layout.
1. Introduction
Allocating a fixed volume of insulation beneath a highway involves a choice between thickness and lateral coverage. A thicker board increases vertical thermal resistance beneath its footprint, while broader coverage moves the insulation edge away from traffic-bearing soil. Highway and railway studies have examined insulating layers through full-scale investigations, field monitoring, and thermal modelling [1,2,3,4,5]. With a fixed volume of insulation, a higher minimum temperature at one monitoring point can coincide with colder conditions elsewhere beneath the traffic lanes.
These spatial differences matter for waste-modified fills that have low thermal conductivity and lose stiffness under freeze–thaw cycling. In an earlier highway programme, a blend of oil-shale waste residue, fly ash, and silty clay showed little change in thermal conductivity after seven laboratory freeze–thaw cycles and retained 59.8–73.9% of its initial dynamic resilient modulus across nine matched stress states [6]. That programme and related studies characterized the soil mixture and a layered composite in which an extruded polystyrene (XPS) board overlies the modified soil. They examined environmental feasibility, thermal properties, freeze–thaw response, and the thermal performance of the composite [7,8,9,10]. The present study uses this established material system to examine how distributing a fixed material allowance across the road section affects thermal exposure.
Spatial variations in subgrade temperature have been studied in cold-region engineering. Liu et al. introduced the thermal static moment to quantify cross-sectional thermal asymmetry and compare filling arrangements [11]. Ižvolt et al. examined lateral freezing and insulation placement near railway traffic load zones [12], while Mi et al. assessed insulation measures in seasonally frozen highway embankments [13]. Using field observations, Ma et al. related subgrade cross-sectional forms to thermal conditions, water distribution, and frost-heave responses [14]. These studies highlight the importance of where protection is needed. Here, material quantities are held fixed to examine how the choice of assessment location affects the preferred board thickness and width. A recent review of seasonally frozen pavements synthesizes field, laboratory, and numerical studies of XPS, foam glass, and recycled materials, emphasizing moisture sensitivity and freeze–thaw durability alongside thermal resistance [15].
The full-scale railway test of Ižvolt et al. [12] compared XPS, expanded clay, and foam-based sub-ballast materials in Žilina, Slovakia. XPS had the greatest thermal resistance among those compared, although the air-freezing indices recorded during the monitored winters were well below the local design value. The railway section differed from the highway cut studied here in its layer structure and loading. In a northern Swedish road embankment, Motamedi et al. [16] measured surface, air, and subsurface temperatures and reported a pronounced effect of snow in the ditch; the road surface temperature averaged 5.8 °C below air temperature during the measurement period. These observations illustrate how field surface temperatures can differ from the prescribed surface temperatures used here.
Thermally modified pavement layers can also address urban heat. Ko et al. [17] reported reduced surface temperatures after reflective pavement treatment in a California neighbourhood, with changes in near-surface air temperature depending on time and exposure. Under simulated solar loading, Shamsaei et al. [18] found that steel slag aggregate in the base and a conductive prime coat reduced the surface temperature and nighttime heat release. In the cold-region road cut considered here, insulation is used to limit subsurface cooling. Surface temperature is prescribed in the model, so the surface energy balance is outside its scope. Mechanical assessment of a sub-base also requires measurements of strength and deformation. Lillian et al. [19] related the California bearing ratio and triaxial strength to pavement stability and durability, complementing the thermal criteria used here.
A point minimum, the minimum over a lane band, and the lateral extent and duration of subzero conditions describe different features of the same temperature field. The road centreline in the present cut section lies in the median, so temperatures are also evaluated at the centres of the traffic lanes. The analysis asks whether point and lane-band minima favour different layouts and whether a warmer minimum is accompanied by a smaller width or shorter duration of exposure below a specified temperature at a given depth. Water supply, soil state, and loading govern how these thermal conditions translate into mechanical damage [20,21,22,23].
A two-dimensional enthalpy formulation [24,25,26] is used to compare fixed-volume layouts. The narrow and full-width layouts are compared under alternative water and ice storage assumptions [27,28], paired changes in boundary conditions, and three idealized cut depths. The numerical implementation is checked against analytical benchmarks and by mesh and time-step refinement. Coefficients calibrated against laboratory clay data are used to predict temperatures at clay depths excluded from calibration and in a separate waste-modified soil specimen. The composite specimen is assessed separately using a retrospective single-parameter boundary fit and within-experiment holdouts.
2. Study Section and Material Allocation
2.1. Highway Section
The reported highway section has a formation 27 m wide in a 4.5–5 m cut [6]. It comprises a 3 m median, two 0.75 m inner marginal strips, four 3.75 m traffic lanes, two 3 m hard shoulders, and two 0.75 m earth shoulders. A symmetric half-section is modelled. The horizontal coordinate x is measured from the road centreline, and depth z is measured downward from the road surface. The modelled traffic lanes occupy x = 2.25–9.75 m; their centres are at x = 4.125 and 7.875 m. The platform ends at x = 13.50 m (Figure 1).
Figure 1.
Idealized half-section and fixed-volume insulation layouts. (a) Road-cut geometry. (b) The coloured bars show three representative allocations with 2bh = 1.35 m3 of XPS per longitudinal metre for the full road. The dashed line marks the outer-lane edge at x = 9.75 m in every layout; it is also the XPS edge only for the narrowest board. (c) Narrow-layout cross-section and the common lane band, x = 2.25–9.75 m and z = 1.01–1.25 m. Points mark the median centre, both lane centres, the lane-band midpoint and the outer-lane edge at z = 1.01 m. (d) Conforming reference mesh of four-node quadrilateral (Q4) elements near the narrow-board edge. Vertical and horizontal axes have different scales.
The layers above the insulation comprise 0.04 m stone mastic asphalt (SMA-13), 0.06 m asphalt concrete (AC-20), 0.08 m asphalt-treated base (ATB-25), 0.54 m cement-stabilized aggregate and 0.20 m gravel. The top of the insulation lies at z = 0.92 m. In the reference layout, the layers below this elevation comprise 0.05 m XPS, 0.30 m waste-modified soil and 0.85 m gravel. The layers above the insulation are idealized as continuous across the median and shoulders. A 1V:1.5H cut slope rises directly from the formation edge to natural ground 4.50 m above the road, with the ditch omitted. A 10 m outer buffer gives a half-domain width of 30.25 m. The bottom lies at z = 15.50 m, 20 m below the upper natural ground.
2.2. Fixed Material Quantities
Continuous boards extend symmetrically from the centreline to half-width b, with uniform thickness h. The XPS volume across the full road per longitudinal metre is
The fixed volume V = 1.35 m3/m corresponds to a 50 mm XPS layer across the 27 m formation. Baseline half-widths are 9.75, 10.125, 10.50, 11.25, 12.00, 12.75 and 13.50 m, with respective thicknesses of 69.23, 66.67, 64.29, 60.00, 56.25, 52.94 and 50.00 mm. The narrowest board ends at the outer-lane edge; the other layouts extend 0.375–3.75 m beyond it. These widths define the discrete candidate set.
The waste-modified soil layer remains 0.30 m thick across the whole platform. Beneath the board, its upper boundary coincides with the underside of the XPS, at depths ranging from z = 0.98923 m in the narrow layout to z = 0.97000 m at full width. Outside the board footprint, gravel occupies the corresponding layer. The base of the replacement layers remains at z = 2.12 m. Integrated full-road volumes are 8.10 m3/m waste-modified soil, 1.35 m3/m XPS and 28.35 m3/m gravel, including the gravel above the board. A fixed interior band at z = 1.01–1.25 m remains inside the waste-modified soil for every layout.
2.3. Material Properties and Experimental Context
The waste-modified soil contains oil-shale waste residue, coal-derived fly ash and silty clay in dry-mass proportions of 2:1:2 (40%, 20% and 40%) [6,8,9,10]. The earlier research programme established this mixture and characterized its thermal, mechanical and environmental properties. Table 1 summarizes the material characterization data used here [6]. After seven freeze–thaw cycles, thermal conductivity decreased from 0.841 to 0.813 W/(m·K), whereas the fraction of the initial dynamic resilient modulus retained was 59.8–73.9% across nine matched stress states [6]. The different thermal and mechanical responses motivate evaluation of freezing exposure alongside material properties. Table S1 identifies the measured properties, adopted inputs and model assumptions.
Table 1.
Material properties reported in Table 2.18 and the text accompanying Figure 2.15 of the thesis [6]. CBR denotes California bearing ratio.
Each freeze–thaw cycle in the conductivity test comprised 24 h at −15 °C and 24 h at +15 °C. A separate set of measurements from the 2019 material study provides the dry-particle heat capacity used below [9].
Han and Gao [8] characterized oil-shale waste from Wangqing, Jilin, comprising semi-coke-derived residue and ash. They classified the fly ash as “Level F and Class I” under GB/T 1596–2017 [8]. Their Table 1 and Table 2 report SiO2, Al2O3 and CaO contents of 56.28%, 13.44% and 6.42% for the oil-shale waste, and 51.00%, 34.80% and 1.80% for the fly ash, respectively. These source-specific chemical results complement the physical properties in Table 1. The reference thermal properties used in the model are listed in Table 2.
Table 2.
Reference properties for sensible heat storage and conduction in the source model [6]. Density and specific-heat entries are model inputs; Cref is their product.
Environmental characterization in the earlier programme included leachate analyses of three modified-soil samples and gravel and silty-clay reference samples [10]. Li et al. reported As concentrations of 0.0071, 0.0077 and 0.0066 mg/L and Sb concentrations of 0.0003, 0.0005 and 0.0004 mg/L for the three samples, compared with background concentrations of 0.0028 and 0.0002 mg/L. The groundwater-quality values used for comparison were 0.0100 mg/L for As and 0.0050 mg/L for Sb. These values apply to groundwater and cannot establish compliance for solid road materials. The study used the horizontal-vibration leaching procedure cited as HJ 557-2009 and measured trace metals by inductively coupled plasma mass spectrometry (ICP–MS) [10]. It is unclear whether the reported samples came from the batch modelled here. Some values in the later report [8] match those in [10], leaving the independence of the batches uncertain. Site-specific long-term freeze–thaw leaching and drainage data are unavailable; changes in water flow and chemistry could alter release in either direction.
Published outdoor-pit observations and two highway temperature profiles provide qualitative context [6,7,8]. The geometries and observation periods differ from those used in the present model, and the available records lack the matched initial field, continuous records of surface and lateral boundary conditions, and independent depth-resolved observations needed for quantitative validation.
3. Materials and Methods
3.1. Heat Transfer and Reference Properties
Two-dimensional conduction is expressed in terms of volumetric enthalpy H:
Equation (2) is solved in SI units, with H in J/m3, k in W/(m·K) and time in seconds. Conductivity k is constant within each material. In the reference representation, volumetric sensible heat capacity is C = ρcp, and the waste-modified soil, gravel and native surrogate use
The liquid fraction f of freezable water is zero below −1 °C, increases linearly from zero to one over −1 to 0 °C, and is one above 0 °C. Latent capacity is Lv = ρw L θf, with ρw = 1000 kg/m3, L = 333.5 kJ/kg and freezable volumetric water content θf = 0.10 m3/m3, giving 33.35 MJ/m3. Water contents are expressed as water-equivalent volumes per unit bulk volume. Actual ice volume is obtained using the density of ice. Pavement, bound base and XPS use sensible storage only. The assumed transition interval regularizes phase change [24,25,26,27,28].
The common −1 to 0 °C interval and reference freezable fraction are model assumptions; freezing curves and freezable water contents for the project gravel and native surrogate were not independently measured. A wider interval and an illustrative temperature-dependent conductivity are examined separately in Section 3.3.
The effective specific heat of XPS in Table 2 was taken from the source model. A related study measured XPS heat capacity [9], but it is unclear whether the specimen or material batch corresponds to that represented in the source model.
The reference model assigns gravel properties to the native domain. For waste-modified soil, the measured dry-particle heat capacity of 908 J/(kg·K) [9] and the density adopted in the source model of 1600 kg/m3 give an effective reference capacity of 1.453 MJ/(m3·K). The source does not specify whether the field density is dry or wet, so it is treated as an effective input. Freezable water is assigned independently of laboratory optimum water content. Section 3.2 introduces explicit constituent storage through preparation-based scenarios.
Heat transfer is modelled by conduction through layers in perfect thermal contact. Geometry and water content are fixed in the reference simulations. Conductivity is constant except in the temperature-dependent sensitivity test in Section 3.3. Moisture redistribution is not modelled; coupled heat–water formulations are discussed in [20,21].
3.2. Water and Ice Storage Scenarios
Two storage scenarios that conserve water mass are applied to the waste-modified soil layer at b = 9.75 and 13.50 m at the baseline and highest forcing amplitudes, A = 21.5 and 25.8 K. A preparation target of 96% of the maximum dry density, 1670 kg/m3, gives ρd = 1603.2 kg/m3. At a gravimetric water content of 0.128, the water mass is 205.2 kg/m3, equivalent to θtot = 0.2052 m3/m3, and the corresponding wet bulk density is 1808.4 kg/m3. The dry-skeleton capacity calculated from this preparation target is 1.456 MJ/(m3·K).
The liquid water content is θl = θr + θf f(T), and the water-equivalent ice content is θi,eq = θf [1 − f(T)]. Thus, θl + θi,eq = θr + θf = θtot at every temperature. The constituent enthalpy is
The frozen sensible capacity is Cf = ρd cs + ρw(θr cw + θf ci), thawed sensible capacity is Cthawed = ρd cs + ρw θtot cw, ΔC = Cthawed − Cf = ρw θf(cw − ci), and Lv = ρw θf L. Here, cs = 908, cw = 4180 and ci = 2100 J/(kg·K), ρw = 1000 kg/m3 and L = 333.5 kJ/kg. The derivative dH/dT = Cf + ΔC f(T) + (ΔC T + Lv)f′(T) retains the ΔC Tf′ term [28]. Enthalpy is continuous at −1 and 0 °C with positive one-sided derivatives; f′ is set to zero at those endpoints. Table 3 gives the two scenarios. Conductivity remains 0.841 W/(m·K); other materials and boundaries retain the reference values.
Table 3.
Waste-modified soil storage scenarios. Water contents are expressed in m3 of water equivalent per m3 of bulk material, sensible heat capacities in MJ/(m3·K), and latent heat capacity in MJ/m3.
Scenario P treats all preparation water as freezable by −1 °C. Scenario U retains the reference freezable inventory, leaving 51.27% of the water liquid at and below −1 °C. Water mass is conserved in both scenarios, and each constituent contributes to the total enthalpy. For gravel and native soil, the effective reference storage properties are used in both scenarios.
3.3. Scenario Design and Boundary Conditions
3.3.1. Seasonal Forcing and Paired Boundary Scenarios
The reference road, cut slope and natural ground share the surface temperature
In Equation (5), t is expressed in days; time steps are converted to seconds for numerical integration using 1 day = 86,400 s. The mean surface temperature is 8.2 °C, and the amplitude A is 17.2, 21.5 or 25.8 K. The baseline amplitude and phase follow the source model, with additional amplitudes at 0.8- and 1.2-times baseline. The bottom is held at 10 °C; zero normal heat flux is imposed at the symmetry plane and the remote vertical boundary. The surface freezing index is
Analytical integration of the imposed sinusoidal temperatures gives surface freezing indices of 733.58, 1185.42 and 1653.74 °C·day. These indices quantify the severity of the three forcing amplitudes. All seven widths are evaluated at A = 21.5 K; the other amplitudes use b = 9.75, 10.50, 11.25, 12.75 and 13.50 m. Selection losses are compared across amplitudes using these five widths.
Three additional pairs of narrow and full-width layouts were compared at the baseline amplitude to test the boundary assumptions. The first moves the prescribed 10 °C bottom from z = 15.5 to 30 m. The second changes native-domain conductivity from 1.15 to 1.416 W/(m·K), the source reference-clay value, while retaining its storage. The third retains a road/platform amplitude of 21.5 K, decreases it linearly along the slope from x = 13.50 to 20.25 m, and applies 17.2 K on natural ground. The mean surface temperature and phase are unchanged, giving continuous forcing at both slope junctions. This damping represents an idealized off-road surface condition. Every pair uses the same fixed evaluation band.
An additional snow-like boundary preserves the prescribed lane temperature up to x = 9.75 m and increases the winter surface temperature progressively over the following 0.75 m, with a maximum increase of +4 K beyond the transition. The increase is 4 max(0, −sin(2πt/365 + 11π/12)) K. This illustrative boundary difference is informed by observed winter warming under accumulated snow on an Alaskan permafrost road [29] and is applied at baseline and strong forcing. Northern Swedish measurements [16] illustrate the distinction between surface and air temperatures; a paired time-series or freezing-index comparison with a representative local road surface was unavailable.
Conductivity-only controls compare waste-modified-soil values of 0.841 and 1.416 W/(m·K) at the same storage properties and geometry. This comparison isolates the effect of conductivity. A separate comparison below accounts for the other properties of conventional fill.
A joint-assumption test combines P or U storage with native-domain conductivity of 1.416 W/(m·K) and a 10 °C bottom at z = 30 m under the strongest forcing, A = 25.8 K. Each storage state is evaluated at b = 9.75 and 13.50 m, with gravel conductivity unchanged. Within each matched pair, full-width-minus-narrow differences are calculated for the median and lane-band minima; local probe temperatures and exposure measures are also retained (Table S3a,b). These paired comparisons test how sensitive the difference between layouts is to the specified assumptions. The P endpoints also undergo joint spatial and temporal refinement using the rules in Section 3.5. Refined runs start from the corresponding converged reference-resolution field interpolated in physical coordinates and continue through complete annual cycles until the full-node periodicity criterion is met.
A matched conventional-fill comparison replaces the modified layer with the reference silty clay described in Section 3.6. The same scenario P storage assumptions are applied to both materials, with all preparation water freezing between −1 and 0 °C and consistent water/ice sensible and latent storage. Their respective dry density, water content, solid heat capacity and conductivity are changed together. The material properties define a controlled scenario in which water migration is excluded. Additional one-factor tests widen the assumed soil freezing interval to −2–0 °C or vary modified-soil conductivity from 0.841 W/(m·K) when thawed to 1.025 W/(m·K) when frozen, interpolated over −1–0 °C. The conductivity ratio 0.39/0.32 comes from Swedish road guideline values reported for a different subgrade [16]; its use here is an approximation for the present mixture. One combined P-storage and snow-like-boundary case is also examined (Table S9).
3.3.2. Geometry and Boundary Conditions for the Cut-Depth Comparison
At A = 21.5 K with reference storage, cut depths dc = 1.5, 3.0 and 4.5 m are compared for b = 9.75 and 13.50 m. Natural-ground depth Z is positive downward from Z = 0; the road lies at Z = dc and z = Z − dc. With the platform ending at x = 13.50 m, the 1V:1.5H slopes meet natural ground at x = 15.75, 18.00 and 20.25 m. The bottom remains at Z = 20 m and 10 °C, and the outer boundary at x = 30.25 m. Equation (5) applies unchanged to road, slope and natural ground. Road-relative layers, properties and per-metre quantities follow Section 2 and Section 3.1.
Changing dc also changes the distance from the road to the bottom boundary from 18.5 to 15.5 m and the distance from the slope crest to the outer boundary from 14.5 to 10.0 m. The comparisons, therefore, reflect changes in both cut depth and distance to the model boundaries.
3.4. Spatial and Temporal Exposure Criteria
The median-centre criterion uses the annual minimum at a fixed physical point:
The lane criterion is the minimum over the final annual cycle and the fixed lane band Ωl, x = 2.25–9.75 m and z = 1.01–1.25 m:
Higher minimum temperatures indicate warmer conditions. The evaluation grid includes every horizontal finite-element (FE) breakpoint within the lane width, both depth limits and internal vertical mesh levels. At each time, the temperature field is interpolated to the same physical coordinates before temporal minima are calculated. Additional point criteria use x = 4.125, 6.00 and 7.875 m at z = 1.01 m. Edge probes at x = 9.25, 9.50 and 9.65 m lie 0.50, 0.25 and 0.10 m inboard, respectively.
For candidate set B, centre-based selection is bc = arg maxb∈BMc(b,A). Its loss relative to the best candidate for the lane minimum is
ΔTsel measures the difference between the highest computed lane-band minimum in B and the minimum for the layout selected using the median temperature. The same comparison applies to any specified point criterion.
For the cut-depth comparisons, Ml(b,A;dc) denotes the lane minimum at cut depth dc. At the baseline amplitude A = 21.5 K, the endpoint contrast is
A positive ΔTend indicates a warmer lane-band minimum with full-width coverage at the specified cut depth. ΔTsel in Equation (9) instead compares the point-selected layout with the candidate giving the highest lane-band minimum in the stated set.
Lateral extent is measured primarily along the lane trace at z = 1.01 m. At each saved time, W(t) is the total length within x = 2.25–9.75 m where T < 0 °C. Threshold crossings are located by linear interpolation within each FE segment at that time. The maximum width Wmax and the annual time integral of W(t), Iw in m·day, quantify spatial extent and persistence. The integral uses trapezoidal quadrature, including the initial state of the final cycle. A threshold–depth check repeats these calculations for T < 0, −0.5 and −1 °C at z = 1.01, 1.10 and 1.25 m, using the refined final cycles of the strongest-forcing endpoints. Widths are calculated from temperatures along the entire lane trace at the same instant.
For each fixed probe, subzero duration is the sum of all portions of the annual cycle for which T < 0 °C; the reported duration is the maximum of those cumulative probe durations. Separate subzero periods at the same probe contribute to its total duration. In contrast, W(t) measures the width below the threshold at a given time. The common band permits comparison at the same physical coordinates in the modified soil; its depth and the tested temperature thresholds have not been established as frost-heave or pavement-damage acceptance criteria.
3.5. Numerical Implementation and Resolution
The road and axisymmetric models use custom finite-element code with four-node quadrilateral (Q4) elements. In the road model, mapped Q4 elements align with layer interfaces and the insulation edge. Reference horizontal spacing is at most 0.50 m in the traffic lanes and 0.25 m near the outer-lane edge; insertion of a board edge can further divide an interval. The target XPS spacing is h/2, giving two to three elements across the reference board, while four elements span the 0.30 m waste-modified soil layer. The conduction term is integrated using 2 × 2 Gaussian quadrature and the enthalpy storage term using nodal quadrature. Backward Euler steps of 0.25 day are solved using a semismooth Newton iteration with a residual-based line search. The archived software environments for the reference clay calibration and the combined road scenarios list Python 3.12.14 with NumPy 2.3.5, SciPy 1.17.0 and pandas 2.2.3. Annual cycles continue until the maximum nodal year-end temperature change is below 0.001 K. ChatGPT (GPT-6.1 Sol, OpenAI) assisted with developing and checking the code for numerical simulation, post-processing and plotting.
Within each time step, convergence is based on the maximum absolute discrete energy residual. For the road solver, the tolerance is 10−8 times the larger of 1 and the initial residual norm, plus 10−9 W/m; the corresponding laboratory-model tolerance is 10−9 times that scale, plus 10−11 W. Both solvers allow at most 80 Newton iterations and use a backtracking residual line search; failure to meet the residual criterion terminates the solve with an error. Table S4 specifies the residuals, constrained degrees of freedom and line-search rules. This within-step criterion is separate from annual periodicity. Road cycling starts from the linear sensible steady solution plus the annual harmonic solution, or from a saved field for continuation and refinement; the initial field of the final cycle is saved so that exposure metrics can be recalculated. Table S5 records the inputs and error definitions for the layered and cylindrical benchmarks.
Analytical benchmarks cover homogeneous diffusion, annual harmonic conduction, a one-phase Stefan limit and a stack of 0.05 m XPS over 0.30 m waste-modified soil. Refinement lowers the maximum diffusion error from 0.0963 to 0.0230 K. Across four interface-aligned meshes, the error in the complex amplitude of the harmonic solution for the layered stack falls from 1.874 × 10−3 to 9.85 × 10−5 K. Joint refinement of space, time and transition width gives Stefan front-location and energy-removal errors of −0.0229% and 0.0062%. The homogeneous harmonic complex-amplitude error reaches 2.451 × 10−4 K, and stack steady-state errors are below 10−9 K in temperature and 10−9 W/m in heat flow.
In the road-model refinement tests, the time step is halved to 0.125 day and spatial resolution is doubled, giving four to five XPS elements and eight waste-modified-soil elements. The strongest-forcing endpoints and three broad baseline candidates are evaluated at both original and refined physical probe locations. Space and time are refined jointly to assess resolution sensitivity [30,31].
To examine small differences between wider layouts and minima near zero, each of the spatial grids r1 and r2 is tested with time steps of 0.25 and 0.125 day. The XPS quantity and evaluation coordinates are fixed. Each new case is cycled until both the maximum nodal year-to-year field difference and lane-band minimum change are below 0.0001 K. Saved fields, including interpolated fields, serve only as initial guesses; the tolerance specifies when cycling stops. Table S8 lists the comparisons and mesh sizes.
All reference, refined and sensitivity metrics are calculated from converged final annual cycles. For each case, minima, fixed-probe durations and simultaneous widths are evaluated over the same final cycle. The four storage-only P/U cases under the strongest forcing reach the annual nodal-drift criterion after six cycles. Calculations and reported differences use unrounded values.
All six cut-depth cases use the mesh-spacing, time-step and periodicity rules above; the dc = 4.5 m cases coincide with the reference endpoints. At each saved time, the lane minimum is found by evaluating the corners of Q4 elements after clipping them to the fixed band. Width and duration use the operators in Section 3.4. The narrow layouts at dc = 1.5 and 4.5 m are also compared after joint refinement.
3.6. Laboratory Calibration and Prediction Checks
The laboratory soil-column freezing apparatus is shown in Figure 2. Two thermostatic water baths (FDL, Nanjing, China) were connected to the temperature-control plates at the column ends. The laboratory tests used 0.45 m specimens inside a steel cylinder with an inner diameter of 0.29 m and a wall thickness of 5 mm (Section 3 of [6]). Homogeneous clay and waste-modified-soil columns were tested alongside a composite of 0.05 m XPS over 0.40 m waste-modified soil. Depth is measured downward from the specimen top; the composite sensor at 5 cm lies at the XPS–soil interface. An axisymmetric Q4 model represents the specimen and steel wall over the 0.45 m specimen height, with effective end-transfer coefficients representing heat exchange at the specimen and wall ends. The nominal bath temperatures are −20 and +15 °C at the top and bottom, respectively. The corresponding Robin conditions are q = αt(Tbath − Tsurface) and q = αb(Tbath − Tsurface). Each condition applies to the specimen core and the steel annulus at that end. Here, q is inward heat-flux density (W/m2), αt and αb are effective transfer coefficients (W/(m2·K)), and Tbath and Tsurface are bath and boundary-surface temperatures. Perfect specimen–wall contact is assumed. The 0.06 m side insulation is represented by cylindrical resistance with conductivity 0.03 W/(m·K), and the outside temperature is held at the median of each run’s initial profile.
Figure 2.
Laboratory soil-column freezing apparatus. The insulated column is in the centre, with a thermostatic water bath on either side. The Chinese labels on the controllers identify the thermostatic water baths. Hoses connect the baths to the column.
The specimen properties are distinct from the road reference in Table 2. Clay and waste-modified-soil dry densities are 1852.8 and 1603.2 kg/m3, with gravimetric water contents 0.122 and 0.128 and conductivities 1.416 and 0.841 W/(m·K) [6]. The specific heat capacities of the dry solids are 1030 and 908 J/(kg·K) [9]; the corresponding values for water and ice are 4180 and 2100 J/(kg·K). All preparation water is assumed freezable over −1 to 0 °C. The component-consistent enthalpy follows Equation (4).
Equation (4) uses the specimen properties above, θr = 0 and θf = θtot, with the liquid-fraction function and full enthalpy derivative defined in Section 3.2. XPS conductivity k = 0.02453 W/(m·K) follows the selected C-group material (Table 2.2 of [6]). Its adopted capacity C = 0.21288 MJ/(m3·K) is calculated from density 40 kg/m3 and specific heat 5322 J/(kg·K) in the source road model (Table 6.1 of [6]). The source specifies grade-203 steel. The model approximates its properties using the following values for grade-304 steel: k = 15 W/(m·K), ρ = 7900 kg/m3 and cp = 500 J/(kg·K) at 20 °C [32].
Effective end-transfer coefficients are calibrated against clay observations at 10, 20, 30 and 40 cm over 1–160 h. The bounded least-squares fit uses log αt and log αb, equal observation weights and bounds of 2–2000 W/(m2·K). The retained reference values, αt = 19.2 and αb = 251 W/(m2·K), represent effective transfer and end-contact effects. The original fitting run reached the maximum number of function evaluations; these coefficients are used to predict temperatures at withheld clay depths of 15, 25 and 35 cm and seven mapped depths in waste-modified soil. For the composite, the core-top, core-bottom and bottom-steel coefficients are retained, while a separate upper-steel coefficient is fitted as described below. Each model is initialized by interpolating the measured axial profile and applying it uniformly across the radius. Temperature probes were positioned on the column centreline, and the temperature-control plates were tightly fixed to the cylinder ends with screws. Centreline predictions are, therefore, the primary comparison; radial ranges describe the simulated spatial variation. The thesis (Section 3 of [6]) reports deviations between the bath setpoints and actual end temperatures but provides no corresponding time histories. The effective thermal contact conductance was not measured.
Additional calibration checks use the same 640 observations, 714-node mesh and 300 s maximum step. Two nearby starting points are tested with explicit least-squares stopping criteria, followed by five bounded one-parameter objective profiles in which the other coefficient is reoptimized (Table S2a,b). Small changes in the coefficients are used to examine the local sensitivity of the objective function. Predictions at the withheld clay depths are then compared between the retained coefficients and the best nearby two-parameter fit on that same mesh. These checks assess optimization termination and local coefficient sensitivity; the resulting ranges describe sensitivity to the calibration settings.
Post-initialization records span 1–160 h for clay, 1–127 h for waste-modified soil and 1–77 h for the composite. Root mean square error (RMSE), mean absolute error (MAE) and bias summarize correlated pairs of predicted and observed temperatures over time; missing observations are omitted. Composite scores distinguish fitted, withheld and transition records. The all-record composite score combines these groups. A descriptive near-zero subset uses observed temperatures within ±1 °C, including the endpoints; clay calibration observations are excluded, while the composite subset is not a holdout set. Predicted radial ranges describe spatial variation within the cylinder rather than statistical prediction intervals.
Analytical checks cover axisymmetric volume weights, radial conduction and Robin boundaries. The Robin steady solution agrees to round-off precision; radial-annulus refinement reduces the error in the logarithmic temperature profile and the relative heat-flow error to 0.000235 K and 0.00733%, respectively. Clay calibration uses 714 nodes; homogeneous-column predictions use 2626 nodes and a 300 s maximum step. For the composite, 39,298 nodes (mesh level 8) and a maximum time step of 150 s are used. Time steps end at observation times. For its fixed upper-steel coefficient, mesh refinement from level 4 to 8 at 150 s changes paired centreline temperatures by at most 0.01434 K. Independently halving the step to 75 s on mesh level 4 changes them by at most 0.02451 K. These spatial and time-step checks were performed separately (Table S6c).
One effective Robin coefficient was fitted retrospectively at the upper-steel annulus of the composite specimen. After inspection of the complete experiment, the data were partitioned into 1–36 h at seven depths excluding 10 cm for fitting, 37–47 h as a transition interval, and early 10 cm and all 48–77 h observations for internal assessment. Unweighted least squares gives an upper-steel coefficient of 165.47 W/(m2·K), held fixed for assessment and refinement. The 252 fitting records, 36 early withheld records, 87 transition records, and 200 late withheld records account for all 575 pairs. Both withheld subsets come from the experiment used for fitting. Other boundary coefficients, material properties and observations, including the recorded 40.25 °C value, are retained. The fitted laboratory coefficient is used only in the specimen model. Section S6 gives the search and numerical checks; Section S7 compares transferred coefficients and limiting steel-end conditions.
4. Results
4.1. Spatial Criteria Select Different Allocations
The annual minimum at the median is highest for the narrowest, thickest board at all three amplitudes, while broader coverage gives higher lane-band minima (Figure 3a,b; Table 4). At baseline, increasing b from 9.75 to 13.50 m lowers the median minimum from 1.65 to 0.40 °C. The lane-band minimum rises from −3.56 °C at b = 9.75 m to −0.54 °C at b = 10.125 m and approximately −0.005 °C at b = 10.50 m.
Figure 3.
Fixed-volume responses at three surface-temperature amplitudes. (a) Median-centre annual minimum. (b) Annual minimum over x = 2.25–9.75 m and z = 1.01–1.25 m. Filled markers denote the common five-width set; hollow markers denote additional baseline widths. (c) Half-width selected by each criterion at reference resolution; symbols are offset to distinguish coincident selections. The candidate sets contain 5, 7 and 5 widths at A = 17.2, 21.5 and 25.8 K. (d) Lane-band gain relative to b = 9.75 m in the common set.
Table 4.
Final-cycle metrics for the 17 reference cases with 1.35 m3/m of XPS, the reference mesh, and a 0.25-day time step. Duration is the greatest cumulative time below zero at any fixed probe during the year. The near-zero b = 10.50 m baseline result is resolution-sensitive (Section 4.4).
In the common five-width reference set, b = 12.75 m gives the highest computed lane-band minimum at each amplitude, with reference-resolution increases of 3.44, 4.03 and 5.22 K over b = 9.75 m (Figure 3d). Under the strongest forcing, however, the difference of 0.014 K between b = 12.75 and 11.25 m at reference resolution changes sign after refinement, leaving their ranking uncertain. All tested layouts have negative reference-resolution lane-band minima at this amplitude.
The inner-lane centre at x = 4.125 m and lane-band midpoint at x = 6.00 m also favour b = 9.75 m at every amplitude. At the outer-lane centre (x = 7.875 m), the highest minimum temperatures occur for b = 10.50, 10.125 and 9.75 m as amplitude increases (Figure 3c). Layout selection, therefore, depends on both the monitored lane and the thermal scenario.
At reference resolution, the minimum of −0.005 °C at b = 10.50 m lies close to the freezing threshold, with a maximum cumulative subzero duration of 5.3 days at a fixed probe. In the separate mesh and time-step checks, the sign changes when the mesh is refined (Section 4.4); the physical occurrence of freezing is, therefore, not resolved by this result.
4.2. Trade-Off Between Minimum Temperature and Subzero Extent
The lowest lane-band temperature in all 17 reference cases occurs at (x, z) = (9.75, 1.01) m, at the outer-lane boundary. This position coincides with the board edge only for the narrowest layout; broader boards extend beyond it. At baseline, the minima in the narrow layout at distances of 0.10, 0.25 and 0.50 m inside the outer-lane edge are −2.38, −0.84 and −0.26 °C, with cumulative subzero durations of 98.7, 72.8 and 39.5 days. The outer-lane-centre minimum is 0.99 °C. Thus, subzero temperatures extend at least 0.50 m inside the lane while the temperature at the outer-lane centre remains above zero.
Figure S4 compares temperature and element-centre heat flux near the lane and board edges for the narrow and full-width layouts, on the same day and on the day when each layout reaches its lane-band minimum. At x = 9.25–9.75 m and z = 1.01–1.25 m, the difference in annual minimum temperature between the full-width and narrow layouts across 216 common probes ranges from +0.634 to +3.927 K at baseline and +0.734 to +5.157 K under strong forcing. These annual minima can occur at different times. When the layouts are compared at the same time, the temperature difference changes sign during the year.
Panels a and b of Figure 4 show simultaneous transverse profiles at the narrow layout’s critical times, day 130.0 at baseline and day 129.25 under strong forcing. Figure 4c relates the lane-band minimum to the annual width–time integral. The narrow-layout maximum subzero width is 0.665 m at baseline, 2.767 m under strong forcing and 0.169 m under mild forcing. The maximum width occurs after the temperature at the lane edge reaches its minimum. Table 5 compares the refined results at different depths and thresholds.
Figure 4.
Transverse temperature profiles and annual subzero exposure. (a,b) Simultaneous profiles at z = 1.01 m on days 130.0 and 129.25 for A = 21.5 and 25.8 K. Line colours identify board half-widths, and shading marks temperatures below zero. The dotted line marks the outer-lane centre, x = 7.875 m. (c) Lane-band annual minimum versus the subzero-width integral for the 17 reference cases; labels give b in metres. Minima use x = 2.25–9.75 m and z = 1.01–1.25 m; width integrals use the same lane width at z = 1.01 m. (d) Full-width-minus-narrow width and integral contrasts from jointly refined cycles at A = 25.8 K with reference storage (Table 5); lines connect sampled depths.
Table 5.
Effects of depth and temperature threshold on exposure in the narrow and full-width layouts under the strongest forcing, using reference storage. Wmax is the maximum simultaneous below-threshold lane width, and Iw is the annual time integral of W(t).
At A = 25.8 K, full coverage raises the lane-band minimum from −5.79 °C in the narrow layout to −0.63 °C. At z = 1.01 m, the maximum subzero widths are 2.77 and 7.50 m for the narrow and full-width layouts, respectively. The corresponding annual width integrals are 156.05 and 490.31 m·day. All broader candidates reach a maximum width of 7.50 m; their integrals increase from 188.59 m·day at b = 10.50 m to 490.31 m·day at full width. Broader coverage moderates edge cooling, while the thinner board allows milder subzero temperatures over more of the shallow trace.
The maximum annual cumulative fixed-probe subzero duration under strong forcing is 124.6 days for narrow coverage and 66.3 days for full coverage. The narrow layout, thus, produces more persistent localized cooling by this metric. In the narrow layout, temperatures at the inner-lane centre and lane-band midpoint remain above zero, while the temperature at the outer-lane centre reaches a minimum of −0.214 °C and is below zero for a total of 35.0 days.
In the refined simulations, the relative extent of exposure in the two layouts depends on depth and temperature threshold (Figure 4d; Table 5). Full coverage gives a warmer annual trace minimum at z = 1.01, 1.10 and 1.25 m. Its maximum below-threshold width and annual integral are greater in three of the nine combinations: T < 0 °C at z = 1.01 and 1.10 m, and T < −0.5 °C at z = 1.01 m. The other six combinations give zero full-width exposure and positive narrow-layout exposure. Full-width temperatures remain at or above −1 °C at all tested depths and at or above 0 °C at z = 1.25 m.
In Table 5, narrow and wide denote b = 9.75 and 13.50 m. All rows use the same two jointly refined final cycles over x = 2.25–9.75 m, with halved target mesh spacings, a 0.125-day step and strict threshold inequalities.
4.3. Paired Sensitivity and Geometry Comparisons
4.3.1. Storage and Boundary Scenarios
At baseline, both preparation-water scenarios give a warmer median with narrow coverage and a warmer lane-band minimum with full coverage (Figure 5a,b; Table 6). In scenario P, the lane-band minima are −3.023 and +0.593 °C for narrow and full-width coverage, respectively. In scenario U, the corresponding minima are −3.447 and +0.592 °C. Thus, the full-width layout raises the lane-band minimum by 3.616 and 4.039 K in P and U, respectively, compared with 3.927 K in the reference case (Figure 5c).
Figure 5.
Paired baseline comparisons at A = 21.5 K. (a) Median-centre minimum. (b) Lane-band minimum. (c) Full-width-minus-narrow lane-band gain; the dotted line denotes the reference gain. Circles and squares denote b = 9.75 and 13.50 m, respectively; horizontal lines connect the two layouts for each scenario. Storage and boundary scenarios are defined in Table 3 and Section 3.3. All comparisons use the same lane band.
Table 6.
Paired comparisons over the fixed lane band at the baseline amplitude. Narrow and wide denote b = 9.75 and 13.50 m. Minimum temperatures are in °C, and differences between lane-band minima are in K.
The boundary scenarios favour narrow coverage at the median and full coverage for the lane-band minimum. The scenarios with a deeper bottom boundary, higher native-soil conductivity, and reduced off-road forcing give lane-band differences of 3.852, 4.042 and 3.925 K, respectively (Figure 5c; Table 6). The full-width minimum with the deeper bottom is 0.223 °C on the fixed evaluation band.
Across the five baseline sensitivity pairs, the inner-lane-centre criterion favours the narrow endpoint. Narrow-layout maximum subzero widths are 0.444, 0.585, 0.724, 0.569 and 0.666 m for P, U, deeper bottom, native conductivity and differentiated forcing, respectively. With full-width coverage, temperatures along the lane trace remain at or above zero in every pair.
Under the strongest forcing, A = 25.8 K, scenarios P and U again favour narrow coverage at the median and full coverage across the lane band. Full-width lane minima are 4.763 and 5.116 K above the respective narrow values (Table 7). At z = 1.01 m and T < 0 °C, narrow coverage has a smaller maximum width and annual width integral but a longer maximum cumulative duration at a fixed probe. Both storage scenarios, therefore, show the shallow-trace trade-off found with reference storage. Table 5 gives the reference-storage responses at other thresholds and depths.
Table 7.
Water-mass-balanced storage scenarios at A = 25.8 K. Extent is evaluated for T < 0 °C at z = 1.01 m. The minimum temperature is evaluated over the fixed lane band.
Narrow and wide denote b = 9.75 and 13.50 m; all four cases use reference resolution and the periodicity criterion in Section 3.5.
The conductivity controls also give opposite point and lane-band rankings. Increasing waste-modified-soil conductivity from 0.841 to 1.416 W/(m·K) raises the lane-band minimum from −3.562 to −2.876 °C in the narrow layout and from +0.365 to +0.556 °C at full width. The lane-band difference decreases from 3.927 to 3.432 K. At the refined resolution, the same change in conductivity raises the full-width lane-band minimum by +0.193 K.
Combining P or U storage with the deeper bottom and higher native-domain conductivity preserves the opposing endpoint rankings (Table S3a,b). At reference resolution, full-width-minus-narrow lane-band gains are 4.758 and 5.103 K for P and U, while the corresponding median-centre differences are −0.875 and −1.022 K. The narrow-layout outer-lane-centre minimum is +0.078 °C in P and −0.003 °C in U. The local temperature, therefore, crosses the freezing threshold between scenarios, even though full coverage gives a warmer lane-band minimum in both.
Table S9 summarizes the paired material and boundary scenarios. At A = 21.5 K, the snow-like boundary reduces the full-minus-narrow lane-minimum difference from 3.927 to 3.188 K; the narrow and full-width minima remain negative and positive, respectively. At A = 25.8 K, the difference changes from 5.157 to 4.263 K, and both minima remain negative. At strong forcing, the matched P clay and modified-soil pairs give full-minus-narrow differences of 3.911 and 4.763 K. Replacing modified soil with clay raises the narrow and full-width minima by 1.017 and 0.166 K, respectively. Conductivity, water content, and heat storage all differ between the materials, so these changes cannot be assigned to conductivity alone. The full-width lane minimum is also warmer in the tests with a wider freezing interval, with temperature-dependent conductivity k(T), and with P storage combined with snow-like forcing. The corresponding widths and cumulative durations are reported alongside these comparisons.
Joint refinement of the combined P endpoints gives lane-band minima of −4.886 and −0.356 °C for narrow and full-width coverage, respectively. The 4.529 K contrast is 0.228 K smaller than at reference resolution and remains positive. The annual width integrals for the narrow and full-width layouts change from 97.93 and 399.14 to 97.70 and 423.46 m·day, respectively. The full-width integral is, therefore, more sensitive to resolution (Table S3a). Both refined cases satisfy the full-node annual-drift criterion after four additional cycles. Scenario U was evaluated at reference resolution.
4.3.2. Effect of Cut Depth on Lane Temperatures and Subzero Exposure
At the baseline forcing amplitude, full-width coverage gives a lane-band minimum 3.91–3.93 K warmer than narrow coverage across the three cut depths (Figure 6b; Table 8). Narrow-layout minima are −3.58, −3.57 and −3.56 °C, and full-width minima are 0.33, 0.34 and 0.37 °C.
Figure 6.
Idealized cut-depth comparisons. (a) Half-sections drawn to scale at cut depths of 1.5, 3.0 and 4.5 m, showing the full-width insulation layout, b = 13.50 m. Natural-ground depth Z is positive downward from Z = 0, and road-relative depth is z = Z − dc. The full platform is 27 m wide; slopes are 1V:1.5H, the outer boundary is x = 30.25 m, and the bottom boundary is at Z = 20 m and is held at 10 °C. The dashed horizontal line marks the natural-ground datum, and colours identify the layers. Layer thicknesses follow Section 2. (b) Annual lane-band minima for the narrow and full-width layouts (circles and squares, respectively) and differences between them for the six cases at A = 21.5 K. (c) Deep-minus-shallow differences, 4.5 m minus 1.5 m, in lane-band minimum and subzero-width integral for the narrow layout. Reference and jointly refined calculations use separate zero-anchored axes; refinement halves target mesh spacings and the time step from 0.25 to 0.125 day.
Table 8.
Paired cut-depth comparisons at A = 21.5 K with reference storage. Narrow and wide denote b = 9.75 and 13.50 m; ΔTend is wide minus narrow. All cases use 1.35 m3/m of XPS, 8.10 m3/m waste-modified soil and a 0.25-day step. Iw uses T < 0 °C on the z = 1.01 m lane trace.
All six minima occur at (x, z) = (9.75, 1.01) m, which is also the point with the longest cumulative subzero duration in the narrow layouts. Measured downward from natural ground, the depths of these minima are Z = 2.51, 4.01 and 5.51 m. Table 8 uses reference resolution; its dc = 4.5 m endpoints also appear in Table 4.
Between dc = 1.5 and 4.5 m, narrow-layout Wmax decreases from 0.683 to 0.665 m and Iw from 42.77 to 41.60 m·day. With full-width coverage, the subzero width, its annual integral, and the duration of subzero exposure are zero at all three cut depths. The narrow and full-width lane minima increase by +0.015 and +0.036 K, respectively, compared with the approximately 3.9 K contrast between the layouts.
Joint refinement of the narrow dc = 1.5 and 4.5 m cases gives lane-band minima of −3.413 and −3.398 °C. The deep-minus-shallow temperature difference changes from +0.0155 to +0.0141 K, and the width-integral difference from −1.167 to −1.183 m·day (Figure 6c). Individual temperature corrections of +0.165 and +0.163 K largely cancel, giving a change of about 0.0014 K in the paired difference. Both refined minima occur at (9.75, 1.01) m.
4.4. Sensitivity of Road-Model Temperatures and Exposure to Numerical Resolution
Under the strongest forcing, the jointly refined narrow and full-width lane-band minima are −5.568 and −0.635 °C, giving a 4.933 K coverage contrast (Figure 7a). Their reference values are −5.787 and −0.630 °C, respectively. Reference and refined probe sets give the same refined minima, including on the trace at z = 1.01 m; the refined narrow-layout median minimum is 0.227 °C. Resolution sensitivity is greater near the narrow board edge.
Figure 7.
Spatial and temporal resolution comparisons. (a) Narrow and full-width endpoints at A = 25.8 K. (b) Three broad layouts at A = 21.5 K. Reference calculations use the reference grid and 0.25-day steps; joint refinement doubles spatial resolution and uses 0.125-day steps. Circles and diamonds indicate reference and refined results, respectively. Arrows give the change from reference to refined values. The same physical lane band is used throughout. Table S8 gives separate mesh and time-step comparisons.
For b = 11.25 and 12.75 m at A = 25.8 K, calculations at r1/0.25, r1/0.125, r2/0.25 and r2/0.125 give differences in lane-band minimum temperature (12.75 m minus 11.25 m) of +0.0140, +0.0139, −0.0015 and −0.0016 K, respectively (Table S8). The ranking, therefore, reverses when the mesh is refined. For b = 10.50 m at A = 21.5 K, the corresponding minima are −0.0053, −0.0068, +0.0052 and +0.0037 °C. Even before uncertainty in field conditions is considered, the sign of the minimum depends on numerical resolution.
After refinement, the maximum subzero widths are 2.870 and 7.500 m for the narrow and full-width layouts, respectively. The corresponding annual integrals are 157.71 and 503.78 m·day, and the maximum cumulative durations at a fixed probe are 124.3 and 67.8 days. The full-width minimum changes little, while the annual integral of subzero width increases from 490.31 to 503.78 m·day. These metrics have different resolution sensitivities. A time-quadrature comparison on saved histories changes reference integrals by at most 0.301 m·day.
In the seven-width baseline set, b = 12.00 m gives the highest reference lane-band minimum, 0.502 °C, which is 4.063 K higher than the lane-band minimum for the layout selected at the median. Refined minima at b = 12.00, 12.75 and 13.50 m are 0.494, 0.466 and 0.361 °C, respectively (Figure 7b). The difference in lane-band minimum temperature between the 12.00 m and full-width layouts is 0.133 K after refinement, close to the reference value of 0.137 K.
4.5. Laboratory Temperature Predictions and Heat Exchange at the Composite Boundary
The calibrated model reproduces the overall temperature histories of both homogeneous columns (Figure 8a,b). With end-transfer coefficients of 20 W/(m2·K) at both ends, the RMSE for clay is 2.023 K; fitting reduces it to 0.457 K across 640 calibration pairs. Predictions at the withheld clay depths and in waste-modified soil give pooled RMSEs of 0.933 and 0.694 K, respectively (Figure 8g; Table 9). The residuals vary with depth (Figure 8d,e). For clay, the RMSE reaches 1.43 K at 35 cm, and waste-modified-soil RMSEs are 1.13 and 1.01 K at 10 and 15 cm.
Figure 8.
Laboratory centreline temperatures and prediction residuals. (a,b) Homogeneous columns with clay-calibrated coefficients, mesh level 2 and a 300 s maximum step. (c) Composite with mesh level 8, a 150 s maximum step and a heat-transfer coefficient at the upper-steel annulus of 165.47 W/(m2·K). Lines are predictions; markers are observations. (d–f) Residuals by depth. Colours and marker shapes identify sensor depths in the common legend. (g) RMSE, MAE and bias by assessment group (Table 9). Composite depth is measured from the top; 5 cm is the XPS–soil interface. Shading marks fitting (1–36 h; Fit*: 10 cm withheld), transition (37–47 h) and internal temporal holdout (48–77 h). The 40.25 °C record at 30 cm and 35 h is retained. Upper panels share temperature scales; time and residual scales differ. Full composite histories are in Figure S1.
Table 9.
Laboratory temperature prediction errors by assessment group. RMSE, MAE and bias are in K; bias is prediction minus observation. The sample size n is the number of paired predictions and observations, which are correlated over time.
The two local restarts change calibration RMSE by less than 5 × 10−5 K; both runs stop when the step-size criterion is met, while the gradient remains above its tolerance (Table S2a). On the common fitting mesh, withheld-depth predictions differ by at most 0.0046 K between the retained reference and the better nearby two-parameter fit. Table 9, therefore, reports the homogeneous-column predictions obtained with the reference clay coefficients.
For observed temperatures within ±1 °C of zero, withheld-depth clay predictions have RMSE 0.373 K and bias +0.041 K across 91 pairs at 15 cm. Waste-modified-soil predictions have RMSE 0.745 K and bias −0.629 K across 77 pairs, comprising 12 at 10 cm and 65 at 15 cm. The composite descriptive subset comprises eight pairs at 5 cm, with RMSE 6.346 K and bias +6.302 K; these records are not an independent holdout set.
The composite model has an all-record RMSE of 2.274 K, MAE of 1.467 K and bias of −0.462 K over 575 pairs (Figure 8; Table 9). These pooled statistics combine 252 fitting observations with withheld and transition observations. The early 10 cm holdout has RMSE 0.671 K over 36 pairs; the 48–77 h internal temporal holdout has RMSE 1.708 K and bias −0.791 K over 200 pairs. Temperature histories at all measured depths and group-specific scores are given in Figure S1 and Table S6a.
Residuals vary by depth. In the late block, 175 of 200 observations—all observations at depths of 10–40 cm—exceed the simulated maximum across the radius, indicating that the model is too cold across the entire core at these depths. At the centreline of the XPS–soil interface, at a nominal depth of 5 cm, the model remains too warm. The recorded temperature reaches 0 °C at 7 h after the experiment began, whereas linear interpolation of the hourly predictions places the 0 °C crossing at approximately 54.2 h. The 54 and 55 h predictions are +0.00247 and −0.00904 °C. The predicted interface temperature remains above −1 °C through 77 h. Probe location and actual end-temperature histories remain uncertain; these discrepancies limit absolute freezing-onset predictions. Full-record RMSEs at 5, 30 and 40 cm are 4.040, 3.849 and 0.542 K, respectively.
The workbook containing the source data for the graph records 40.25 °C at 30 cm and 35 h. The instrument log is unavailable, and the cause of this reading remains unknown. All observations were retained in the primary analysis. Removing this single record from the original fitting window and refitting changes the upper-steel coefficient from 165.47 to 176.31 W/(m2·K), the late internal-holdout RMSE from 1.708 to 1.758 K, and the predicted interface crossing from 54.21 to 49.90 h. Section S10 also reports the error obtained when the observation was omitted from scoring but the original coefficient was retained.
In Table 9, clay calibration and homogeneous-column predictions use their respective fitting and prediction meshes and coefficients. Composite results use the fitted upper-steel coefficient on mesh level 8 at 150 s. Initial profiles are excluded. The all-record composite row combines fitting and assessment data; the late row is an internal temporal holdout from the same experiment. The transition block contains 87 additional records (Table S6a).
5. Discussion
5.1. The Thermal Objective Determines the Allocation
For a fixed volume of insulation, greater board thickness raises the minimum temperatures at the median and the inner-lane centre, while broader coverage moves the board edge beyond the outer lane. These spatial effects explain the different layouts favoured by point and lane-band criteria. The lane-centre comparisons show that the choice of monitoring location also matters within traffic-bearing soil. Under strong forcing, narrow coverage produces colder and more persistent edge exposure with a smaller maximum shallow subzero width. Full coverage gives both warmer minima and less exposure in six of the nine threshold–depth combinations in Table 5.
Zhuo et al. [2] compared XPS, tyre chips, foam glass aggregates and foamed concrete, identifying material and thickness combinations with comparable insulation performance. Huang et al. [4] examined field temperature and moisture responses of polystyrene- and bottom-ash-insulated road sections. In the railway model of Ižvolt et al. [12], uniform XPS protected the centreline while lateral freezing entered the active load zone; thickening the insulation near the berm and embankment edge prevented subgrade-surface freezing within that zone under the analysed conditions. This supports considering edge protection alongside centreline temperature. The present comparison holds XPS quantity fixed, so extending coverage necessarily reduces thickness. The resulting trade-off can be assessed from point and lane-band minima, the width below zero at a given time, and the cumulative subzero duration at a fixed location.
The engineering objective also distinguishes buried insulation from conductive steel-slag base and prime-coat layers used to reduce surface temperature and nighttime heat release under solar loading [18]. Here, higher conductivity raises annual minima when both the mean surface temperature and the prescribed bottom temperature are above zero (Section 4.3.1), illustrating how the effect of conductivity depends on the seasonal heat supply. The fixed-volume thickness–coverage comparison, therefore, complements material selection: thermal resistance, moisture sensitivity and freeze–thaw durability [15] must be considered alongside spatial thermal exposure and the strength and deformation measures reviewed for sub-base materials [19].
5.2. Thermal Assessment of Representative Route Sections
A thermal comparison starts by defining the protected region, evaluation depth and decision metrics. Under the strongest forcing in the jointly refined reference model, full-width coverage raises the lane-band minimum by 4.93 K compared with the narrow board, while the maximum simultaneous subzero width at z = 1.01 m increases from 2.87 to 7.50 m. The choice of layout, thus, depends on whether priority is given to the lowest temperature or to the width exposed to freezing. Neither measure by itself establishes a frost-heave or structural acceptance limit. Hydraulic, mechanical and project-specific boundary evidence is needed to connect these indicators to performance.
For the idealized 4.5 m cut under the strongest forcing, all tested reference-resolution width candidates have a negative lane-band minimum. If the design objective is to keep the lane band at or above freezing, other insulation volumes or layouts would need to be assessed. The ranking of wider boards with similar minima and the sign of minima near zero remain sensitive to resolution (Section 4.4).
The section comparison covers continuous boards of uniform thickness. Further comparisons could include edge treatments and longitudinal transitions, while a surface-energy assessment can address differential pavement-surface icing [33].
5.3. Model Applicability and Validation
The road comparisons use the specified storage and boundary conditions. Preparation-based storage scenarios, including an assumed residual-liquid fraction in U, represent alternative assumptions about the contributions of water and ice to heat storage; gravel and native soil use effective reference properties. Application to an individual section should account for local moisture, snow cover, surface exchange, slope orientation, interface contact and temperature-dependent properties.
Hansson et al. [21] compared coupled heat–water predictions with column-freezing observations and examined alternative boundary-transfer assumptions when local discrepancies remained. The steel-end comparisons here likewise test sensitivity to uncertain heat exchange at the ends of the laboratory column, while the road formulation holds water inventory fixed. Kelleners [34] separated calibration and subsequent validation periods and reported depth-resolved comparisons, providing a methodological basis for distinguishing fitted observations from prediction targets. Here, predictions at withheld clay depths are assessed within a single experiment. Applying the clay coefficients to waste-modified soil tests transfer between specimens. In the composite test, the fitting and assessment data were selected retrospectively from the same experiment. Tubini et al. [25] separately assessed phase-change solver convergence and accuracy against analytical benchmarks. The reported indicators quantify thermal exposure; translating them into frost heave, strength retention or pavement service life requires hydraulic and mechanical evidence.
The boundary adjustment reduces pooled temperature error while leaving substantial depth- and time-dependent discrepancies. Unmeasured end-surface histories, contact conductance and initial radial temperatures prevent attribution to a unique physical cause. The boundary coefficient was fitted and assessed retrospectively using different portions of the same experiment. Road-layout contrasts are assessed separately through paired scenarios: shared errors may cancel, whereas edge-related errors can depend on configuration. Prediction errors from the laboratory tests, therefore, cannot be used directly as uncertainty bounds for differences between road layouts. Engineering use of absolute temperatures, freezing thresholds or layout rankings requires project-specific validation of the layered assembly.
The analysis distinguishes numerical discretization, prescribed boundary and material scenarios, model-structure discrepancy, and uncertainty in observation locations and boundary histories. The ranges reported for the scenarios describe sensitivity to the specified conditions. Field freezing predictions also depend on physical inputs and model validity beyond numerical convergence.
6. Conclusions
The fixed-volume comparisons lead to four conclusions.
- Across all three surface-temperature amplitudes, annual minima at the median centre, inner-lane centre and lane-band midpoint favour the narrowest of the tested uniform-thickness boards. The highest lane-band minima in the common five-width set are 3.44–5.22 K higher than the corresponding lane-band minima for the layout selected at these points. Under the strongest forcing, joint refinement gives a 4.93 K advantage for full-width coverage over the narrow endpoint.
- Under the strongest forcing with reference storage, the refined maximum subzero widths for narrow and full-width coverage are 2.87 and 7.50 m, respectively, for T < 0 °C at z = 1.01 m. Full coverage gives a warmer lane-band minimum with a larger maximum shallow width and annual integral. Full-width coverage gives greater exposure in three of the nine threshold–depth combinations. In the other six, only the narrow layout falls below the threshold.
- The lane-band minimum remains higher with full-width coverage than with narrow coverage in the tested storage, boundary and material scenarios, including a combined storage–shoulder forcing case. The magnitude of this difference depends on the assumptions tested. The closely competing b = 11.25 and 12.75 m widths at the strongest forcing reverse order under mesh refinement, and the baseline b = 10.50 m minimum changes sign; the ranking of the two wider layouts and the freezing classification of the near-zero case both remain uncertain.
- The minimum temperature identifies the coldest part of the lane band, the simultaneous width measures the extent of exposure, and the cumulative duration measures its persistence at a fixed location. At the XPS–soil interface, the observed 0 °C crossing at about 7 h and the predicted crossing at about 54.2 h show how much the fitted model delays freezing onset. The boundary fit is assessed using holdouts from the same experiment. Applying these indicators to a road design requires local material and boundary data and evidence linking thermal exposure to hydraulic and mechanical behaviour.
Supplementary Materials
The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/ma19235065/s1. Table S1. Evidence and parameter provenance for the thermal comparison. Table S2a. Retained calibration reference and two nearby numerical checks. Table S2b. Bounded scalar objective profiles with one transfer coefficient fixed and the other searched in logarithmic coordinates. Table S3a. Combined-scenario final-cycle results. Table S3b. Full-width-minus-narrow contrasts in median-centre (ΔMc) and lane-band (ΔMl) annual minima for the reference and combined scenarios. Table S4. Nonlinear solution, annual cycling and initialization settings for the numerical models. Table S5. Verified inputs, analytical references and error measures for the diffusion, phase-change, layered and cylindrical checks. Table S6a. Matched-resolution centreline temperature scores. Figure S1. Composite centreline temperature histories at eight nominal depths. Table S6b. Late-block depth-specific discrepancies at mesh level 8 and 150 s. Table S6c. Separate mesh and time-step comparisons, with all differences and late-block RMSE values in K. Figure S2. Indoor comparisons with coefficients fixed after clay calibration. Table S7. Fixed-coefficient steel-annulus boundary tests at 48–77 h. Figure S3. Fixed-coefficient steel-end tests. Table S8. Lane-band annual minimum temperature (°C). Table S9. Paired lane-band minima and thermal exposure under selected scenarios. Figure S4. Temperature and heat flux for narrow (a,c) and full-width (b,d) layouts at A = 25.8 K with reference storage, r1/0.25 d. Table S10. Complete-record fitting versus single-record omission and refitting. References [6,7,8,9,10,16] are cited in the Supplementary Information.
Author Contributions
L.H. (Leilei He): Conceptualization, methodology, writing—original draft, writing—review and editing, project administration. Y.W.: Conceptualization, methodology, resources, data curation, writing—review and editing. Z.Z.: Investigation, formal analysis, funding acquisition. L.H. (Leilei Han): Investigation, validation, formal analysis, data curation, writing—review and editing. All authors have read and agreed to the published version of the manuscript.
Funding
This research was supported by the Natural Science Basic Research Program of Shaanxi Province (grant No. 2023-JC-YB-842) and the National Fund Cultivation Special Project of Xi’an University of Architecture and Technology (grant No. X20240085).
Institutional Review Board Statement
Not applicable.
Informed Consent Statement
Not applicable.
Data Availability Statement
The original contributions presented in this study are included in the article/Supplementary Material. Further inquiries can be directed to the corresponding author.
Acknowledgments
ChatGPT (GPT-6.1 Sol, OpenAI) assisted with developing and checking the code for numerical simulation, post-processing and plotting. The authors retain responsibility for the methods, interpretation and content of the article.
Conflicts of Interest
Leilei He and Yuyao Wang were employed by CCCC First Highway Consultants Co., Ltd. Leilei Han was employed by Shaanxi Provincial Transport Planning Design and Research Institute Co., Ltd. The remaining author declares that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
References
- Oosterbaan, M.D.; Leonards, G.A. Use of Insulating Layer to Attenuate Frost Action in Highway Pavements. Highw. Res. Rec. 1965, 101, 11–27. [Google Scholar]
- Zhuo, Z.; Zhu, C.; Ali, A.; Mehta, Y.; Lein, W.; DeCarlo, C.; Elshaer, M.; Hewage, S.D.A.; Cai, W. Comparative study of different materials for insulated pavement in cold regions. Cold Reg. Sci. Technol. 2023, 210, 103851. [Google Scholar] [CrossRef] [Scilit]
- Ižvolt, L.; Kardoš, J.; Dobeš, P.; Navikas, D. Comprehensive Assessment of the Effectiveness of the Application of Foam and Extruded Polystyrene in the Railway Substructure. Buildings 2024, 14, 31. [Google Scholar] [CrossRef] [Scilit]
- Huang, Y.; Molavi Nojumi, M.; Hashemian, L.; Bayat, A. Performance Evaluation of Different Insulating Materials using Field Temperature and Moisture Data. Transp. Res. Rec. 2021, 2675, 595–607. [Google Scholar] [CrossRef] [Scilit]
- Liu, J.; Tian, Y. Numerical studies for the thermal regime of a roadbed with insulation on permafrost. Cold Reg. Sci. Technol. 2002, 35, 1–13. [Google Scholar] [CrossRef] [Scilit]
- Han, L. Study on Structural Stability and Application of Cold Resistant Layer Subgrade in Seasonal Frozen Region. Doctoral Dissertation, Jilin University, Changchun, China, 2021. [Google Scholar]
- Han, L.; Wei, H.; Zhang, Y.; Zhang, J.; Wang, F. Study on Cold Resistance Performance of Composite Subgrade Structure in Seasonal Frozen Regions. Appl. Sci. 2020, 10, 4681. [Google Scholar] [CrossRef] [Scilit]
- Han, L.; Gao, Y. Integrated cold resistance subgrade system utilizing oil shale waste and XPS insulation for sustainable infrastructure in seasonal frozen regions. Sci. Rep. 2025, 15, 31534. [Google Scholar] [CrossRef] [Scilit]
- Li, Q.; Wei, H.; Zhou, P.; Zhang, Y.; Han, L.; Han, S. Experimental and Numerical Research on Utilizing Modified Silty Clay and Extruded Polystyrene (XPS) Board as the Subgrade Thermal Insulation Layer in a Seasonally Frozen Region, Northeast China. Sustainability 2019, 11, 3495. [Google Scholar] [CrossRef] [Scilit]
- Li, Q.; Wei, H.; Han, L.; Wang, F.; Zhang, Y.; Han, S. Feasibility of Using Modified Silty Clay and Extruded Polystyrene (XPS) Board as the Subgrade Thermal Insulation Layer in a Seasonally Frozen Region, Northeast China. Sustainability 2019, 11, 804. [Google Scholar] [CrossRef] [Scilit]
- Liu, H.; Niu, F.; Guan, H. An engineering evaluation index of thermal asymmetry in subgrade and its optimal design in cold regions. Cold Reg. Sci. Technol. 2017, 137, 1–6. [Google Scholar] [CrossRef] [Scilit]
- Ižvolt, L.; Dobeš, P.; Mečár, M.; Navikas, D. Analysis of the Influence of Incorporating Different Thermal-Insulating Materials into the Sub-Ballast Layers. Buildings 2025, 15, 239. [Google Scholar] [CrossRef] [Scilit]
- Mi, X.; Zhang, W.; Zhang, G.; Wang, X. Study on anti-frost heave effect of new thermal insulation subgrade of highway in seasonally frozen soil regions. PLoS ONE 2025, 20, e0318682. [Google Scholar] [CrossRef] [Scilit]
- Ma, C.; Tai, B.; Yue, Z. Impact of subgrade cross-sectional forms on the thermo-mechanical stability of high-speed railway subgrades in cold regions. Eng. Geol. 2025, 346, 107898. [Google Scholar] [CrossRef] [Scilit]
- Saeed, R.; Dimitrova, R.; Vanapalli, S. Alternative Materials for Improving Pavement Performance in Cold Regions: A Comprehensive Review. Geotech. Geol. Eng. 2026, 44, 261. [Google Scholar] [CrossRef] [Scilit]
- Motamedi, Z.; Tommik, K.; Mattsson, H.; Laue, J.; Knutsson, S. Field measurements at a road embankment during a winter season in northern Sweden. Transp. Geotech. 2025, 52, 101553. [Google Scholar] [CrossRef] [Scilit]
- Ko, J.; Schlaerth, H.; Bruce, A.; Sanders, K.; Ban-Weiss, G. Measuring the impacts of a real-world neighborhood-scale cool pavement deployment on albedo and temperatures in Los Angeles. Environ. Res. Lett. 2022, 17, 044027. [Google Scholar] [CrossRef] [Scilit]
- Shamsaei, M.; Carter, A.; Vaillancourt, M. Utilisation of steel slag aggregates to propose novel asphalt pavement structures alleviating urban heat islands. Road Mater. Pavement Des. 2025. online ahead of print. [Google Scholar] [CrossRef] [Scilit]
- Lillian, N.; Ahmed, S.B.; Krishnan, D.; Eze, V.H.U. Comprehensive evaluation of sub-base materials for road pavements, integrating California bearing ratio and triaxial compression tests for enhanced stability and durability: A systematic review. Discov. Civ. Eng. 2025, 2, 116. [Google Scholar] [CrossRef] [Scilit]
- Harlan, R.L. Analysis of coupled heat-fluid transport in partially frozen soil. Water Resour. Res. 1973, 9, 1314–1323. [Google Scholar] [CrossRef] [Scilit]
- Hansson, K.; Šimůnek, J.; Mizoguchi, M.; Lundin, L.-C.; van Genuchten, M.T. Water Flow and Heat Transport in Frozen Soil: Numerical Solution and Freeze–Thaw Applications. Vadose Zone J. 2004, 3, 693–704. [Google Scholar] [CrossRef] [Scilit]
- Konrad, J.-M. Influence of freezing mode on frost heave characteristics. Cold Reg. Sci. Technol. 1988, 15, 161–175. [Google Scholar] [CrossRef] [Scilit]
- Style, R.W.; Peppin, S.S.L.; Cocks, A.C.F.; Wettlaufer, J.S. Ice-lens formation and geometrical supercooling in soils and other colloidal materials. Phys. Rev. E 2011, 84, 041402. [Google Scholar] [CrossRef] [Scilit]
- Voller, V.R.; Swaminathan, C.R. General source-based method for solidification phase change. Numer. Heat Transf. Part B Fundam. 1991, 19, 175–189. [Google Scholar] [CrossRef] [Scilit]
- Tubini, N.; Gruber, S.; Rigon, R. A method for solving heat transfer with phase change in ice or soil that allows for large time steps while guaranteeing energy conservation. Cryosphere 2021, 15, 2541–2568. [Google Scholar] [CrossRef] [Scilit]
- Brent, A.D.; Voller, V.R.; Reid, K.J. Enthalpy-porosity technique for modeling convection-diffusion phase change: Application to the melting of a pure metal. Numer. Heat Transf. 1988, 13, 297–318. [Google Scholar] [CrossRef] [Scilit]
- Watanabe, K.; Mizoguchi, M. Amount of unfrozen water in frozen porous media saturated with solution. Cold Reg. Sci. Technol. 2002, 34, 103–110. [Google Scholar] [CrossRef] [Scilit]
- Dall’Amico, M.; Endrizzi, S.; Gruber, S.; Rigon, R. A robust and energy-conserving model of freezing variably-saturated soil. Cryosphere 2011, 5, 469–484. [Google Scholar] [CrossRef] [Scilit]
- Schneider von Deimling, T.; Lee, H.; Ingeman-Nielsen, T.; Westermann, S.; Romanovsky, V.; Lamoureux, S.; Walker, D.A.; Chadburn, S.; Trochim, E.; Cai, L.; et al. Consequences of permafrost degradation for Arctic infrastructure—Bridging the model gap between regional and engineering scales. Cryosphere 2021, 15, 2451–2471. [Google Scholar] [CrossRef] [Scilit]
- Roache, P.J. Perspective: A Method for Uniform Reporting of Grid Refinement Studies. J. Fluids Eng. 1994, 116, 405–413. [Google Scholar] [CrossRef] [Scilit]
- Celik, I.B.; Ghia, U.; Roache, P.J.; Freitas, C.J.; Coleman, H.; Raad, P.E. Procedure for Estimation and Reporting of Uncertainty Due to Discretization in CFD Applications. J. Fluids Eng. 2008, 130, 078001. [Google Scholar] [CrossRef] [Scilit]
- Outokumpu. Core Range Datasheet: Stainless Steels for Corrosive Environments. 1560EN/4, November 2022. Table 7, Physical Properties at 20 °C, Grade 304. 2022. Available online: https://www.outokumpu.com/en/products/product-ranges/-/media/files/products/core/outokumpu-core-range-datasheet.pdf?modified=20251117111909&revision=025e9931-a1d5-4c8f-8ff5-f881d38916da (accessed on 14 October 2026).
- Côté, J.; Konrad, J.-M. A numerical approach to evaluate the risk of differential surface icing on pavements with insulated sections. Cold Reg. Sci. Technol. 2005, 43, 187–206. [Google Scholar] [CrossRef] [Scilit]
- Kelleners, T.J. Coupled Water Flow and Heat Transport in Seasonally Frozen Soils with Snow Accumulation. Vadose Zone J. 2013, 12, 1–11. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.







