Abstract
Hybrid steel–basalt fiber ultra-high-performance concrete (UHPC) was investigated at a constant total fiber volume fraction of 2%. A fiber-free reference, two mono-fiber mixtures, and three hybrid mixtures were tested. Mechanical tests included compression of 100 mm cubes and 40 mm × 40 mm loaded sections of prism halves, splitting tension, and flexure using two prism geometries. Actuator-based load–displacement curves were integrated to derive comparative pre- and post-peak energy indices. Nondestructive testing, two-dimensional visible-void analysis, SEM–EDS, empirical regressions, and a bootstrap-based hybrid-effect index complemented the results. Steel fibers did not improve the compressive strength of 100 mm cubes but markedly enhanced post-peak response. The 2ST mixture increased splitting tensile strength by 74.8% and total splitting-test energy by 218% relative to the reference. The 1.5ST + 0.5B mixture provided the most favorable hybrid splitting response. Fresh-state air content described variation in UPV (R2 = 0.752) and dynamic modulus (R2 = 0.874), whereas coarse section-visible void area did not. No hybrid mixture showed statistically supported positive synergy: 1ST + 1B was antagonistic in splitting strength and pre-peak energy, and all hybrids were antagonistic in smaller flexural prisms. The steel-to-basalt ratio should be optimized for the target response rather than selected on the assumption of intrinsic synergy.