Abstract

Driven by the large-scale deployment of renewable electricity, water electrolysis has emerged as a leading pathway for high-efficiency hydrogen production. Under practical operating conditions, gas evolution and gas–liquid two-phase flow inside electrolyzers substantially reshape electrode interfacial states and the in-cell mass transfer environment and have been reported to cause performance losses on the order of 10–30% under unfavorable conditions. This review summarizes the evolution of electrode-generated bubbles during nucleation, growth, detachment, and coalescence, and consolidates the fundamental features of two-phase hydrodynamics and phase-distribution patterns in electrolyzer channels. Progress and limitations of major two-phase modeling approaches are then assessed with respect to their capability to resolve the relevant interfacial and transport processes. The impacts of gas evolution and two-phase flow on electrochemical performance, stability, and durability are subsequently discussed. Finally, recent advances in two-phase-flow management—through flow-field organization and structural design, as well as the introduction of external physical fields—are reviewed, together with experimental and diagnostic methods used to quantify bubble behavior and phase distributions. This review aims to provide a coherent understanding of the governing behaviors, research tools, and performance implications of gas evolution and two-phase flow in water electrolysis, and to inform electrode/transport-layer design, flow-field management, and the development of predictive numerical models.

1. Introduction

Under net-zero commitments, energy systems are shifting away from fossil-fuel dominance toward low-carbon configurations increasingly anchored in renewable electricity. However, the intrinsic intermittency and variability of renewable resources pose major challenges for large-scale integration and spatiotemporal balancing, creating an urgent need for a clean energy carrier that enables efficient energy conversion, long-duration storage, and long-distance transport [1]. Owing to its high gravimetric energy density, zero carbon emissions at the point of use, and strong coupling potential across electricity, heat, chemicals, and transportation, hydrogen is widely regarded as a critical hub linking renewable power to end-use sectors [2]. On the one hand, hydrogen can serve as a long-duration storage medium and an energy-transport vector, enhancing grid flexibility and renewable utilization. On the other hand, it can act as a key feedstock and reductant for deep industrial decarbonization, offering viable routes for hard-to-abate sectors such as steel and chemicals. Therefore, motivated by the dual demands of energy transition and industrial decarbonization, developing safe, cost-effective, and scalable hydrogen production technologies is of great importance [3].
Among available hydrogen production routes, water electrolysis is regarded as a key pathway for scalable “green hydrogen” supply because of its abundant feedstock, high product purity, and direct compatibility with renewable electricity. With declining renewable power costs and continued advances in electrolyzer hardware, water-electrolysis technologies are evolving toward higher current densities, higher power densities, and longer lifetimes [4,5,6]. Under high-load operation, however, continuous hydrogen and oxygen evolution and their accumulation within electrodes and flow channels inevitably give rise to gas–liquid two-phase flow inside the cell [7]. It has been widely recognized [8] that bubble evolution and distribution on electrode surfaces and within channels/porous media can modify local mass-transport and conduction environments, ultimately manifesting as differences in voltage losses, efficiency, and operational stability, and thus becoming a major constraint for high-load operation.
Building on mechanistic questions surrounding how two-phase processes emerge and how they impact performance, substantial experimental and modeling efforts have been carried out at multiple levels. At the interfacial scale, in situ visualization and mechanistic analyses have shown that bubble nucleation, growth, detachment, and coalescence govern surface bubble coverage and interfacial renewal on electrodes [9,10,11]. These interfacial processes can further develop into spatially non-uniform two-phase flow in channels and porous media [12], where phase distribution is highly sensitive to flow-field architecture, material properties, and operating conditions [13,14,15,16]. At the device performance level, it has been reported that the presence and non-uniform distribution of gas introduce additional losses through multiple pathways, including reduced effective reaction area and hindered interfacial renewal, void-fraction-induced changes in the effective conductive cross-section and associated current maldistribution, and gas holdup in porous structures that restricts liquid supply and aggravates mass-transport limitations [17,18]. Collectively, these effects increase cell voltage and may accelerate degradation of materials and components [19,20,21,22,23]. Motivated by these insights, a broad range of bubble-management and two-phase-flow control strategies has been explored [24,25,26,27,28,29], including electrode/transport-structure design, flow-field organization and feed optimization, and the use of external physical fields or dynamic operating modes to mitigate bubble coverage and holdup, improve phase distribution, and enhance mass transfer. With continued advances in diagnostics and multiscale simulation capability, research activity in this area has expanded rapidly, creating a clear need for a systematic synthesis of governing behaviors, methodological toolkits, and optimization strategies to support comparable and verifiable design and operational guidance. Although a number of review articles on water electrolysis have been published, most have primarily emphasized materials, electrochemistry, or system-level design [4,25,30,31,32]. Comparatively less attention has been devoted to a systematic consolidation of gas evolution and two-phase processes [9,11,33,34], particularly the multiscale links among bubble dynamics, phase distribution, transport effects, voltage losses, and two-phase-flow management strategies.
In this review, multiscale two-phase processes triggered by gas evolution in water electrolysis devices are examined, with emphasis placed on governing behaviors, characterization and modeling methods, and engineering-oriented management concepts. First, the typical features of the complete bubble life cycle on electrode surfaces are summarized, together with the key factors governing bubble coverage and interfacial renewal. Two-phase transport modes and phase-distribution characteristics in channels and porous media are then synthesized, and their sensitivities to structural parameters and operating conditions are discussed. Next, the applicability and principal limitations of major two-phase-flow modeling frameworks in water electrolysis contexts are assessed, and the mechanisms by which gas presence and non-uniform distributions influence voltage-loss components, efficiency, and operational stability are consolidated. Finally, representative two-phase-flow management strategies—including structural design, flow-field optimization, and external-field control—are reviewed alongside experimental diagnostics and characterization methods. This review is intended to support electrolyzer design, operating-condition optimization, and the development of verifiable predictive models, and an outlook is provided on research directions that warrant particular attention.

2. Gas Evolution on the Electrode Surface

This chapter elucidates the four fundamental stages of the complete lifecycle of bubbles during electrolysis: nucleation, growth, detachment, and coalescence. Gas evolution on the electrode surface significantly alters surface coverage and influences mass transfer, thereby directly impacting electrolytic performance. Furthermore, it constitutes the prerequisite for two-phase flow development within the electrolyzer. By analyzing the physical mechanisms and influencing factors underlying these processes, a correlation between microscopic phenomena and macroscopic bubble dynamics is established. Ultimately, this foundational knowledge empowers the targeted engineering of advanced, low-resistance gas-evolving electrodes alongside the precise optimization of internal channel configurations.

2.1. Nucleation

Bubble nucleation represents the initial step of the gas evolution reaction, marking the phase transition of molecules from a dissolved to a gaseous state, and ultimately determining the initial bubble density and subsequent growth behavior. Fundamentally, nucleation is a characteristic thermodynamic non-equilibrium process. Driven continuously by electrochemical reactions, product molecules accumulate at the interface, resulting in a localized concentration (Cs) that is significantly higher than the bulk saturation concentration (Cb). Functioning as the paramount energetic catalyst, this extreme supersaturated state shatters the phase transition resistance [35,36]. Consequently, dissolved species coalesce into stable, discrete gaseous entities—marking the true genesis of the gas evolution reaction. Ultimately, the severity of this interfacial imbalance—mathematically captured by the supersaturation ratio (ξ = Cs/Cb − 1)—rigidly dictates not only the spatial density of these nascent voids but also their subsequent expansion trajectories across the substrate.
Inside the electrolyzer, dissolved product molecules (e.g., H2 and O2) maintain a dynamic equilibrium with their gaseous phases, a state characterized by equal chemical potential across both phases. In dilute solutions, the equilibrium solubility follows Henry’s Law, where the concentration of dissolved molecules is proportional to their partial pressure in the gas phase [37]. The local solubility near the electrode is modulated by various factors, including temperature, pressure, and electrolyte composition. For instance, in ambient conditions, the solubility of H2 and O2 in aqueous solutions decreases with rising temperature. This occurs because gas dissolution is typically exothermic; thus, increased thermal energy shifts the equilibrium toward the gas phase [38]. Electrolyte concentration also significantly impacts solubility. Maximilian et al. found that H2 solubility decreases as KOH concentration increases, dropping by approximately 80% when the mass fraction of KOH rises from 1 wt.% to 30 wt.% [39]. Furthermore, while both H2 and O2 are sparingly soluble in water, O2 generally exhibits a higher equilibrium solubility than H2. This is attributed to the higher polarizability of O2 molecules, which facilitates stronger interactions with water molecules [40]. These discrepancies in equilibrium solubility directly influence the localized supersaturation, thereby dictating the subsequent nucleation process.
Despite the profound significance of supersaturation, accurately obtaining the concentration field and the true requisite supersaturation near the electrode remains challenging due to limitations in measurement techniques; consequently, related research is relatively sparse. Discrepancies in the underlying principles of various measurement and calculation methods further lead to inconsistent supersaturation data across different studies. Based on hydrogen bubble growth rates, Westerheide and Westwater [41] roughly estimated the supersaturation for hydrogen evolution on platinum electrodes in 0.1 and 1.0 M H2SO4 to be 8–24. By combining potential-time and concentration overpotential analyses, Shibata [42] calculated a maximum hydrogen supersaturation (ξ) of 177 on Pt electrodes in a 1 M H2SO4 solution. Vogt [35] subsequently corrected Shibata’s results by accounting for reactant dilution effects, yielding an adjusted hydrogen supersaturation of approximately 100. Integrating microscopic observation with electrochemical methods, Sakuma [43] calculated that the requisite supersaturation for oxygen bubble nucleation on Pt electrodes under microgravity and alkaline conditions is approximately 800–1200, based on the required nucleation time.
Existing research indicates that supersaturation is governed by various factors, including current density, electrolyte properties, and external fields. Shibata [42] observed that for a smooth Pt electrode in 1 M H2SO4, increasing the current density from 0.001 A·cm−2 to 0.1 A·cm−2 results in a 16-fold increase in the localized hydrogen concentration. Furthermore, the maximum supersaturations for hydrogen and oxygen molecules were found to be 177 and 70, respectively [42,44], demonstrating that requisite nucleation conditions vary among different gases. Additionally, departing from conventional gravity and acidic environments, Sakuma [43] measured a requisite oxygen supersaturation of 800–1200 under microgravity and alkaline conditions. This value is significantly higher than the 70 obtained in Shibata’s experiments, a discrepancy potentially attributed to the “single-phase natural convection” induced by density gradients under normal terrestrial gravity, which effectively depletes the surface supersaturation.
The onset of macroscopic gas evolution is strictly governed by a critical threshold in local molecular supersaturation. Resolving the exact spatial distribution of these initial phase transitions, however, necessitates high-temporal-resolution optical tracking. By deploying high-speed photography, Westerheide [41] demonstrated that early-stage cavities do not populate the electrode in a stochastic manner. Instead, gas generation is highly localized and repeatedly pinned to specific topographical defects—such as mechanical scratches, grain boundaries, and micro-pits—which consistently serve as preferential active sites. The activation and distribution of these nucleation sites are neither uniform nor constant, with their density and rate heavily influenced by the electrode microstructure, material properties, and operating conditions.
Electrode geometric morphology is a crucial determinant of nucleation, yet direct observation on complex architectures remains challenging. Utilizing Scanning Electrochemical Cell Microscopy (SECCM), Liu [45] verified that the incorporation of nanostructures significantly reduces the requisite supersaturation for bubble nucleation compared to planar configurations, thereby facilitating the nucleation process. However, mechanically scratched nanostructured films exhibited degraded HER performance, a phenomenon attributed to the poor electrical conductivity of the thicker nanostructures. Tanaka [46] discovered that the abundance of bubble nucleation sites increases alongside the surface roughness of Pt-Ti electrodes. This occurs because highly rough electrodes possess more surface cracks, providing prevalent geometric irregularities where bubble nuclei predominantly form.
The intrinsic wettability of materials regulates the nucleation process by altering the gas–liquid–solid three-phase contact angle (θ) [47,48,49]. Utilizing direct laser writing, Rox [50] fabricated pillared surfaces with dual wettability, observing that the hydrophobic pillars served as preferential nucleation sites. Liu [45] found that enhanced hydrophobicity in nanostructured MoS2 electrodes promotes bubble nucleation. Furthermore, experimental observations by Sakuma [43] under microgravity environments indicated that increased surface hydrophobicity results in a flatter attachment of gas nuclei on the Pt electrode, thereby reducing the surface energy required to form a new interface. Quantitative results demonstrated that as the contact angle increases from 55° to 105°, the requisite supersaturation for bubble nucleation decreases, and the necessary nucleation time is reduced from 0.08 s to 0.04 s.
Beyond the microstructural and intrinsic properties of the electrode, operating conditions and external factors also govern the nucleation process. Elevated current densities or applied voltages accelerate the gas generation rate and increase supersaturation, thereby facilitating nucleation. Sequeira [51] noted that high current densities can activate microscopic defects that fail to act as nucleation sites under low supersaturation levels, leading to an increased site density. Through potentiostatic experiments, Lu [52] found that the nucleation site density at an applied voltage of 1.8 V is tenfold greater than that at 1.5 V. Moreover, at an identical potential, the nucleation site density in a pH = 13 solution ranges from approximately 14 to 55 bubbles·cm−2, substantially higher than the 1 to 29 bubbles·cm−2 observed in a pH = 7 solution. Furthermore, Matsushima [53] observed that an increase in magnetic field strength (from 0 T to 5 T) reduces the number of nucleation sites. This reduction is primarily attributed to magnetohydrodynamic (MHD) effects, which perturb the adjacent flow field and subsequently restrict the localized accumulation of dissolved oxygen.
To elucidate the nucleation mechanism, early research predominantly adopted Classical Nucleation Theory (CNT). By analyzing the system’s energy to determine the corresponding energy barrier, this theory posits that the free energy change (ΔG) during homogeneous nucleation comprises two components: the decrease in volumetric free energy resulting from gas phase evolution, and the increase in surface free energy required to form a new interface. By solving for the extremum of the system’s Gibbs free energy change (ΔG), the energy barrier for homogeneous nucleation ( Δ G hom ∗ ) is derived as follows:
Δ G hom ∗ = 16 π σ 3 3 Δ G v 2
where σ denotes the gas–liquid interfacial tension, and ΔGv represents the change in volumetric free energy. In the context of homogeneous nucleation, the formal growth phase can only be initiated once the energy of the molecular clusters surpasses this energy barrier [54,55].
In practice, electrolysis reactions occur at the electrode–electrolyte interface, thereby constituting heterogeneous nucleation. Assuming an ideally smooth electrode surface, the inherent wettability between the electrolyte and the electrode significantly reduces the nucleation energy barrier, as shown in Figure 1. Based on the Volmer model, the modified relationship between the heterogeneous nucleation energy barrier ( Δ G het ∗ ) and the homogeneous nucleation energy barrier ( Δ G hom ∗ ) is expressed as follows [56,57,58]:
Δ G het ∗ = Δ G hom ∗ × Φ θ
Φ θ = 2 − cos θ 1 + cos θ 2 4
where θ denotes the contact angle, and Φ θ represents the geometric parameter. This theory indicates that the hydrophobicity of the electrode surface (i.e., a larger θ) significantly diminishes the geometric factor Φ θ , thereby lowering the nucleation energy barrier. This conclusion consistently aligns with the experimental findings of Liu, Sakuma, and colleagues.
Figure 1. Variation in Gibbs free energy in classical nucleation theory.
However, the requisite supersaturation calculated based on heterogeneous nucleation theory is exceedingly high (approximately 1000) [54]. Conversely, electrochemical experiments by Vogt and Westerheide demonstrated that during electrolysis, bubbles are frequently generated in massive quantities at extremely low supersaturations (typically ξ < 100). Furthermore, Jones [59] discovered that even with the introduction of extreme contact angle corrections (e.g., θ approaching 180°), the theoretical nucleation rate calculated by CNT remains substantially lower than experimental observations. Simultaneously, under high current densities, nucleation sites on the electrode surface are densely distributed, meaning bubbles generated at adjacent sites may interfere with the localized nucleation process. These analyses collectively indicate that the nucleation mechanism on actual electrode surfaces is far more intricate than postulated by classical nucleation theory.
Due to current difficulties in observing nucleation phenomena in multi-bubble systems at high current densities, Jones [59] proposed the widely accepted gas cavity theory, predicated on the reality that numerous defects and pits exist locally on actual electrode surfaces. This theory posits that nucleation occurs within pre-existing nano/micro-scale gas cavities. Because the radius of curvature of these cavities exceeds the critical nucleation radius, the need to overcome the nucleation energy barrier is completely obviated. This theory effectively elucidates why surfaces featuring nanostructures [45] or elevated roughness [46] significantly promote nucleation by supplying an increased number of large-radius gas cavities. Consequently, it resolves the discrepancy wherein the experimentally observed nucleation supersaturation is substantially lower than CNT predictions. Based on the gas cavity theory, corresponding research has also been conducted within water electrolysis systems. Utilizing this theory, Volanschi [60] fabricated a single cavity on a microelectrode—comparable in diameter to the bubbles—to control bubble nucleation on the electrode surface, successfully achieving periodic bubble generation. Combining gas cavity theory with wettability studies, Raman [61] constructed hydrophobic cavity structures on silicon electrodes. These engineered pits served as preferential bubble nucleation sites, effectively mitigating bubble coalescence issues during the study of individual bubble growth.
In summary, existing research demonstrates that the bubble nucleation process on electrode surfaces is governed by factors such as electrode microstructure, material properties, and operating conditions. The theoretical framework for bubble nucleation has evolved from classical homogeneous and heterogeneous nucleation to the gas cavity theory, which provides a superior explanation for nucleation phenomena on actual electrodes. Nevertheless, numerous challenges remain for the further investigation and advancement of surface bubble nucleation. First, relevant experimental observation techniques require significant enhancement. Constrained by current characterization methods, observing the frequency and site density of bubble nucleation at high current densities and on complex electrode surfaces remains exceedingly difficult, and directly capturing the evolution of nano-cavities is highly challenging. Second, studies focusing on the behavioral characteristics of the nucleation process are currently limited. Most experiments solely consider the influence of isolated parameters, leaving a gap in research regarding nucleation characteristics under the comprehensive influence of multiple coupled variables; systematic investigations and a fundamental understanding of bubble nucleation across diverse operating conditions are urgently needed. Furthermore, existing nucleation theories overlook the impact of multi-bubble evolution, and the gas cavity theory currently lacks specific mathematical expressions for nucleation rate and frequency, necessitating further theoretical refinement. Future efforts should focus on advancing experimental observation and characterization techniques to acquire precise data on bubble nucleation location, density, and frequency. Leveraging these advancements, systematic experimental studies addressing the impact of various parameters can be conducted, ultimately facilitating the development of bubble nucleation models that accurately reflect actual electrode surface structures and further guiding effective bubble management.

2.2. Growth

Once embryonic gas cavities breach the critical radius (rc), their initial thermodynamic penalty is fully paid, triggering rapid volumetric inflation across the substrate. This macroscopic expansion is perpetually fueled by a severe chemical potential gradient—a strict imbalance between the highly pressurized vapor core and the adjacent supersaturated electrolyte [9]. Consequently, the core governing mechanism of bubble growth is dictated by the mass transfer kinetics of dissolved gas molecules migrating from the bulk liquid phase to the gas–liquid interface and subsequently vaporizing into the gas phase.
Owing to their larger dimensions compared to initial nuclei, growing bubbles are significantly more amenable to experimental observation. Extensive research indicates a temporal increase in bubble dimensions during the growth process [62,63], with the morphological evolution on conventional electrodes being heavily influenced by factors such as surface wettability. Experimental observations by Brandon [64] and Westerheide [41] demonstrated that hydrogen bubbles evolving on Pt microelectrodes maintain a virtually spherical morphology. Similarly, Hu [65] observed the spherical growth of oxygen bubbles on TiO2 nanoarray electrodes. For such spherical bubbles, the geometric radius is conventionally adopted as the primary quantitative metric. However, with advancements in microscopic techniques, Yang [66] discovered that bubbles attached to the electrode surface are not perfect spheres but rather spherical caps, necessitating additional parameters such as bubble height, contact line radius, and contact angle for comprehensive characterization. Based on electrochemical noise measurements, Bouazaze [67] postulated that hydrophobic surfaces induce excessive spreading at the bubble base, predisposing the bubble to a flattened shape. Conversely, bubbles on hydrophilic surfaces more closely approximate a sphere, which is consistent with the experimental observations of Sakuma [43]. Furthermore, Yang [68] observed that under microgravity (0.0005 g), diminished buoyancy forces impede bubble detachment; instead, bubbles oscillate at their nucleation sites under the influence of Marangoni convection—a behavior markedly distinct from the morphological changes observed under normal terrestrial gravity.
As bubble dimensions continuously evolve throughout the growth phase, the bubble radius remains the most prevalent metric utilized to quantify size. For perfectly spherical bubbles, the geometric radius directly represents the bubble radius, whereas an equivalent characteristic radius is employed when the morphology deviates from a perfect sphere. Extensive empirical evidence indicates that the temporal evolution of the bubble radius follows distinct regularities. In current experimental studies, the functional relationship between bubble radius (RB) and time (t) is conventionally fitted using the following power-law equation:
R B = β × t x
where β denotes the growth coefficient and x represents the time exponent.
Numerous studies investigating electrolytic bubble growth have employed this power-law relationship for data fitting, as shown in Table 1. Utilizing CCD imaging to precisely track hydrogen and oxygen bubbles on Pt microelectrodes in sulfuric acid, Brandon [64] observed that the time exponent (x) gradually decreases from an initial value of 1.0 (t < 10 ms) to 0.5, ultimately stabilizing at approximately 0.3 over extended periods (t > 100 ms). A congruous three-stage behavior was similarly observed by Matsushima [69] in a 0.36 M KOH solution. However, these three distinct stages do not invariably manifest under all conditions. Constrained by observation techniques, Westerheide [41] conducted preliminary observations of HER on Pt electrodes in 0.1 and 1 M H2SO4, finding the bubble growth radius to be proportional to the square root of time (x = 0.5). Investigating under identical parameters, Yang [66] reported microscopic observations indicating x = 0.3, with no evidence of the x = 0.5 regime. Donose [70] monitored hydrogen bubble growth in ultrapure water at the platinized tip of an Atomic Force Microscope (AFM) cantilever, failing to capture the x = 1 phenomenon. Wang [71] discovered that the time exponent for photoelectrolytically generated hydrogen bubbles on TiO2 nanoarray electrodes was 0.3, whereas standard electrolysis yielded x = 0.5. Bashkatov [72] further observed that the time exponent for hydrogen bubbles growing on Pt microelectrodes drops to approximately 1/4 during the late stages of growth.
Table 1. Summary of Experimental Studies on Bubble Growth Time Exponents (x).
Based on these experimental observations of temporal radius evolution, Brandon postulated that these three stages correspond to distinct governing mechanisms: x = 1 indicates inertia-controlled growth, x = 0.5 signifies diffusion-controlled growth, and x = 0.3 denotes electrochemical reaction-controlled growth. The inertia-controlled stage is remarkably brief and involves minute bubble radii, making accurate experimental recording highly challenging; consequently, the x = 1 regime is frequently absent in experimental captures. Additionally, the predominant control mechanism varies with experimental conditions. For instance, the abbreviated diffusion distance of product molecules on microelectrodes renders the electrochemical reaction the rate-determining step, thereby bypassing the x = 0.5 stage entirely.
Bubble growth is not an isolated physical process; experimental studies emphasize that the growth rate is heavily modulated by electrode structural properties, operating conditions, and external fields. Investigating the impact of varying material wettability, Sakuma [43] demonstrated that the growth coefficient (β) during the x = 1 stage increases proportionally with the contact angle. Moreover, as surface hydrophobicity increased, the time exponent corresponding to the x ≈ 0.5 regime shifted from 0.41 to 0.54. This acceleration is attributed to the larger contact angles of bubbles on hydrophobic electrodes, which promotes preferential growth along the electrode surface, thereby accelerating the absorption of dissolved gas molecules. Based on CCD observations, Matsushima [69] found that bubbles on microelectrodes in 0.36 M KOH grew more rapidly under microgravity (x = 0.32) compared to normal gravity (x = 0.26), a conclusion corroboratively supported by the numerical simulations of Yang [68]. Exploring single-bubble growth on copper electrodes in NaCl solutions, Chandran [73] experimentally determined that increasing the current from 30 mA to 60 mA substantially accelerates the growth velocity of attached bubbles, elevating the growth coefficient (β) from 0.22 to 0.63. Vogt [74] further highlighted that introducing forced convection intensifies the mass transfer processes at the gas-evolving electrode surface, thereby promoting bubble growth.
Because the dynamics of gas phase evolution on electrode surfaces are inherently complex—encompassing physicochemical phenomena such as surface electrochemical reactions, diffusion of supersaturated molecules within the electrolyte, and mass transfer across the bubble interface [75]—formulating a comprehensive kinetic model is highly challenging (as illustrated in Figure 2). Consequently, contemporary research on bubble dynamics typically deconstructs the growth phase into three distinct regimes: inertia control, diffusion control, and electrochemical reaction control. By approximating these distinct regimes as quasi-steady-state processes, several bubble growth kinetic models have been developed based on their respective governing mechanisms.
Figure 2. Schematic diagram of bubble growth kinetic processes.
In the fleeting moments immediately following nucleation (typically t < 10−4 s), the bubble expands primarily by absorbing supersaturated molecules from the solution. During this period, growth is dominated by an exceptionally high Laplace pressure and is governed by liquid inertia; this behavior can be predicted using the Rayleigh–Plesset equation [76]. Assuming the liquid surrounding the bubble is incompressible, the viscous forces and surface tension are negligible compared to the dominant inertial forces during this stage. Furthermore, the pressure differential (ΔP) driving bubble growth is assumed to remain constant. By simplifying the kinetic equations based on these assumptions and solving the resulting differential equations, the temporal evolution of the bubble growth radius (RB) during the inertia-controlled stage is derived as follows:
R B t = 2 Δ P 3 ρ 0.5 × t
where ρ denotes the electrolyte density, and Δ P = P B t − P ∞ t represents the pressure differential between the bubble interior and the surrounding liquid. This differential can be estimated utilizing the Laplace equation, where P B t designates the internal bubble pressure and P ∞ t represents the bulk liquid pressure at infinity [9,77,78].
As supersaturated product molecules transfer from the solution into the gas phase, the localized supersaturation depletes rapidly, thereby rendering diffusion the rate-determining step. For the diffusion-controlled growth regime, electrochemical reactions do not represent the rate determination step for the bubble growth rate. Consequently, early investigations primarily adopted the diffusion-controlled growth models originally formulated by Scriven [79] from boiling heat transfer studies. Predicated on key assumptions—namely, an infinite quiescent liquid medium, the negligible influence of inertia and viscosity on pressure, and the maintenance of spherical symmetry—the general governing equation for spherically symmetric phase growth within an infinite medium was derived by Scriven as follows:
R B t = 2 β K t
where the growth coefficient β depends on the density and composition of each phase, and K denotes the thermal diffusivity.
Pioneering the adaptation of Scriven’s boiling-induced bubble growth model, Westerheide [41] substituted the thermal diffusivity (K) with the molecular diffusion coefficient (D). Consequently, a diffusion-controlled growth model applicable to electrolytic conditions was formulated: R B t = 2 β D t , where D represents the molecular diffusion coefficient. As experimental investigations into electrolytic bubble growth advanced, subsequent studies derived diffusion-controlled models directly rooted in the specific growth mechanisms characteristic of electrolytic environments. Hu [65] posited that bubble growth under diffusion control is primarily governed by two factors: the concentration gradient-driven diffusion of molecules from the bulk solution to the bubble surface, and the localized micro-convection induced by the expansion of the gas–liquid interface. Although the phase transition of molecules traversing the gas–liquid interface necessitates a certain duration to achieve equilibrium, this conversion is generally assumed to be substantially faster than the diffusion process. Thus, it does not constitute the rate-determining step and can be treated as a quasi-steady-state process. Predicated on these assumptions, the mass transfer equation was employed to describe the diffusion process. By analyzing the fluxes of both diffusion and micro-convection (J1 and J2), the temporal evolution of the bubble radius on the electrode surface was derived as
R B t = A + A 2 + 2 A D O 2 t 1 / 2
where A = V mol c s − c b , Vmol represents the molar volume of the gas at the experimental temperature, cb is the molecular concentration in the bulk solution, cs is the concentration at the bubble surface, and D O 2 denotes the molecular diffusion coefficient. This formulation is consistent with the empirically observed R B t = β × t 1 / 2 power-law relationship. Furthermore, the model elucidates that both the localized supersaturation c 0 − c i and the molecular diffusion coefficient ( D O 2 ) exert a profound influence on the bubble growth trajectory.
Building upon Hu’s work [65], Wang [71] noted that when the electrode dimensions are significantly smaller than the bubble size—corresponding to practical microelectrode experiments or the late stages of growth—the diffusion distance of electrogenerated gas molecules from the solid surface to the bubble interface becomes negligible. This scenario is functionally equivalent to the direct injection of electrochemically generated gas into the bubble interior. Consequently, diffusion ceases to be the rate-determining step, and bubble growth is instead dictated by the surface electrochemical reaction rate. Applying the principle of mass conservation, the relationship between bubble radius and time under these conditions is calculated as
R B t = 3 V mol J r 4 π 1 / 3 t 1 / 3
where Jr designates the mass flux generated by the chemical reaction.
This model confirms that when bubble growth is reaction-controlled, the temporal radius evolution satisfies the R B t = β × t 1 / 3 scaling law. Because the growth coefficient β is directly correlated with the surface reaction rate, this model effectively explains the accelerated bubble growth observed at higher current densities. However, because the specific formulation of Jr was not provided in the aforementioned model, Yang [66] integrated the electrode reaction rates with the ideal gas law to formulate a more comprehensive kinetic model for reaction-controlled growth:
R B t = 3 I ¯ R g T 4 n F p 0 π 1 / 3 t 1 / 3
where I ¯ represents the average current, Rg is the universal gas constant, T denotes temperature, n specifies the number of electrons transferred in the electrode reaction, F is the Faraday constant, and p0 signifies the ambient pressure. This model congruently adheres to the x = 1/3 scaling law while explicitly demonstrating how operating parameters—such as current density, temperature, and pressure—modulate the bubble growth velocity.
In summary, the existing literature on bubble growth reveals that bubbles evolving on electrode surfaces predominantly assume spherical or spherical-cap morphologies. Morphological variations during growth are highly susceptible to factors such as contact angle modifications and microgravity environments. Furthermore, the temporal evolution of surface bubbles is conventionally described using a power-law relationship, conceptually divided into three principal regimes based on the time exponent: x = 1, x = 1/2, and x = 1/3. Depending on the specific experimental systems and operating parameters, both the growth rate and the dominant growth regime may shift, potentially exhibiting alternative scaling laws such as x = 1/4. The formulation of distinct kinetic models corresponding to these specific governing mechanisms has successfully elucidated several experimental phenomena. Nevertheless, current kinetic models for electrolytic bubble growth are universally predicated on the assumption of perfect sphericity. In practical electrolysis, growing bubbles inevitably deviate from a perfectly spherical shape, and such interfacial deformations may precipitate shifts in the underlying growth mechanisms. Therefore, future research must prioritize empirical studies to refine characterization methodologies for non-spherical bubbles and subsequently upgrade existing growth kinetic models. Additionally, existing theoretical frameworks predominantly rely on quasi-steady-state assumptions to model single-bubble dynamics. In reality, electrolytic bubble growth is an inherently transient process involving the collective evolution of multiple interacting bubbles. The development of transient kinetic models addressing multi-bubble systems remains a critical frontier requiring further investigation.

2.3. Detachment

Severing the capillary adhesion at the triple-phase boundary permanently liberates the gas void into the bulk electrolyte, triggering the onset of fully developed two-phase transport. The temporal footprint of this pinning phase strictly dictates the dynamic active surface area; prolonged gas residence inherently exacerbates localized ohmic resistance and inflates overall energetic consumption. Mitigating these parasitic penalties necessitates the engineered acceleration of departure kinetics. Actively manipulating substrate topology, inherent wetting profiles, and localized hydrodynamic shear forces thus provides a definitive structural route to maximize electrolyzer efficiency [80].
As a bubble’s dimensions continuously expand, detachment occurs the moment the forces promoting detachment surpass those inhibiting it. Conventionally, during the detachment sequence, the triple-phase contact line remains pinned to the electrode surface. Subsequently, the bubble undergoes necking; as this neck progressively narrows, it ultimately precipitates the bubble’s release from the electrode [81]. With advancing research, specific anomalous detachment behaviors have been identified. Investigating the hydrogen evolution reaction (HER), Bashkatov [72,82,83] discovered that when the cathodic potential exceeds −3 V, hydrogen bubbles exhibit an oscillatory growth phenomenon. As shown in Figure 3, the exceptionally high working potential observed in this system is primarily attributed to the formation of micro-bubble layer on the electrode surface. This interfacial gas accumulation induces a significant increase in ohmic resistance, which in turn leads to a substantially elevated reaction overpotential, ultimately shifting the actual operational potential to a much higher level. Furthermore, during the detachment of macro-bubbles grown on microelectrodes, a microbubble layer resides at the base, entirely replacing the continuous triple-phase contact line. Beyond conventional detachment modes, Westerheide [41] identified a coalescence-induced detachment mechanism: when two equivalently sized bubbles coalesce, the resulting merged bubble undergoes a jumping motion that can facilitate direct detachment from the electrode surface.
Figure 3. (a) Scheme of the slightly deformed spherical bubble, sitting on the Pt electrode, and the carpet of microbubbles beneath, with their relevant geometric parameters. (b) Carpet thickness δ and elongation of bubble foot ε versus time (c) Measured carpet thickness versus time in 0.5 mol·m−3 H2SO4 for different potentials [82].
To quantitatively describe the surface detachment process, empirical studies predominantly rely on metrics such as detachment diameter and detachment frequency. These parameters are critical as they not only dictate the surface gas coverage but also inherently govern the phase distribution characteristics of the two-phase flow within the electrolyzer channels. The existing literature indicates that bubble detachment is modulated by a confluence of variables, primarily encompassing electrode structural properties and operating parameters.
The micro/nanostructure and wettability of the electrode surface are paramount factors influencing detachment. Xu [84] demonstrated that, compared to planar configurations, electrodes featuring nano-arrays exhibit “superaerophobic” characteristics underwater. The adhesion force between the bubble and the nanostructured electrode is reduced to merely one-tenth of that on a planar electrode, consequently diminishing the detachment diameter from 350 μm to approximately 50 μm. Conversely, Chen [85] reported contradictory findings during a photoelectrochemical OER study on TiO2 nanorod array electrodes. Despite observing a decreased bubble contact angle, the detachment diameter paradoxically increased from 330 μm to 470 μm. This anomalous phenomenon was ultimately attributed to the magnified thermal Marangoni forces present within that specific experimental system, which effectively hindered bubble detachment. Furthermore, while bubble nucleation and forces are inherently linked to the activity and properties of electrode materials, current research remains heavily centered on Platinum (Pt) substrates. Discrepancies in electrode pretreatment, current densities, and electrolyte environments across different investigations make it challenging to draw systematic conclusions regarding the impact of electrode composition on gas evolution. Therefore, further comprehensive research is required to address these gaps.
Furthermore, the species of gas evolved on an identical electrode surface distinctly impacts the detachment diameter. Monitoring hydrogen and oxygen bubble detachment in a Proton Exchange Membrane (PEM) electrolyzer, Li [86] observed that oxygen bubbles exhibit a larger contact angle (approximately 136.4°) and a correspondingly larger detachment diameter (80 μm). In contrast, hydrogen bubbles display a smaller contact angle (approximately 125.6°) and a smaller detachment diameter (60 μm). Liu [87] investigated gas evolution on horizontal nickel wire electrodes in a 30 wt.% KOH solution, discovering that under identical current densities, the average detachment diameters of the two gases differed by nearly an order of magnitude. For instance, at 0.15 A·cm−2, the average detachment diameters for hydrogen and oxygen bubbles were 23.3 μm and 92.86 μm, respectively. However, observing vertical nickel electrodes in 0.1–4 M KOH solutions, Zhang [88] found the detachment diameters of hydrogen and oxygen bubbles to be virtually identical: 0.59 mm and 0.60 mm at 3.0 × 10−4 A·cm−2, and 1.09 mm and 1.08 mm at 6.0 × 10−4 A·cm−2. This discrepancy across studies is likely attributable to variations in KOH concentration, current density, and other system-specific parameters. The disparity in detachment diameters between hydrogen and oxygen bubbles can be attributed to several factors. Primarily, the interfacial wettability differs between the two species; experimental observations indicate that oxygen bubbles exhibit larger contact angles, thereby intensifying the pinning effect of surface tension. Additionally, the inherent density differential plays a critical role. Due to its lower density, the hydrogen bubble experiences a more pronounced buoyancy force, enabling premature detachment from the electrode surface compared to its oxygen counterpart.
Current density serves as the critical parameter governing the generation rate of gas molecules; therefore, its variation profoundly influences the detachment process. Li [86] and Nie [89] found that, under otherwise constant conditions, an increase in current density enlarges the detachment diameter. Specifically, as the current density escalated from 0.02 A·cm−2 to 0.1 A·cm−2, the average bubble detachment diameter increased by a factor of 1.5, a phenomenon driven by elevated nucleation site density, accelerated growth rates, and intensified coalescence at higher current densities. Similarly, Massing [90] observed significant increases in detachment diameter on microelectrodes at elevated current densities, attributing this to the thermal Marangoni effect induced by localized Joule heating. Investigating OER on horizontal nickel wires, Liu [87] found that as current density increases, the average detachment diameter enlarges while the detachment frequency gradually declines before stabilizing. Specifically, increasing the current density from 0.15 A·cm−2 to 0.35 A·cm−2 expanded the average oxygen bubble detachment diameter from 92.86 μm to 182.01 μm, while the frequency dropped from 142 Hz to 112 Hz.
Experimental results across varying electrolyte environments demonstrate that solution concentration and composition significantly govern bubble detachment. Zhang [88] observed that as the KOH concentration increases, the average detachment diameter of hydrogen bubbles on vertical nickel wires exhibits a downward trend. Specifically, raising the KOH concentration from 0.5 M to 4 M reduced the critical detachment diameter from 1.08 mm to 0.24 mm, as shown in Figure 4a. This reduction was attributed to the increased solution viscosity, which narrows the hysteresis ( Δ θ = θ 1 − θ 2 ) between the advancing contact angle ( θ 1 ) and receding contact angle ( θ 2 ). This diminished hysteresis effectively weakens the upward vertical surface tension (the restraining force), thereby facilitating easier detachment. Park [91] discovered that electrolyte species also modulate detachment behavior. The requisite detachment time for hydrogen bubbles on Pt microelectrodes in H2SO4 solutions was significantly longer than in HClO4, HCl, and HNO3 solutions. For example, at a potential of −0.16 V vs. RHE, the detachment time in H2SO4 was 1.619 s, whereas it remained under 0.2 s in the other three solutions. Because the growth duration was prolonged, hydrogen bubbles evolved larger detachment diameters in H2SO4, a conclusion thoroughly corroborated by microscopic observations, as shown in Figure 4b.
Figure 4. (a) Impact of KOH concentration on bubble detachment radius. Redrawn from data in Ref. [88]. (b) Impact of electrolyte species on bubble detachment radius. Redrawn from data in Ref. [91].
Because industrial applications frequently employ flow systems to expedite the removal of gaseous products, the impact of forced electrolyte convection on detachment has also been investigated. Through experimental observation and theoretical simulation of electrolysis on Pt electrodes within a flow system, Li [86] found that elevating the flow velocity decreases the detachment diameters of both gases. As the flow velocity increased from 0.70 cm·s−1 to 13.3 cm·s−1, the oxygen detachment diameter decreased from 84 μm to 35 μm, and the hydrogen detachment diameter shrank from 70 μm to 25 μm. Furthermore, the detachment time was found to be inversely proportional to the flow velocity. This occurs because increased flow velocities amplify both the fluid drag and shear lift forces, augmenting the total vertical detaching force and thereby facilitating bubble release.
Bubble detachment is ultimately dictated by the competitive balance of various force components acting upon the bubble’s center of mass; a bubble departs the electrode only when the net detaching force exceeds the net adhering force. Therefore, establishing a comprehensive and precise bubble detachment kinetic model is of paramount importance for predicting surface gas behavior during electrolysis. During their growth and detachment phases, electrogenerated bubbles are subjected to the following primary forces. A schematic illustration of the forces acting on a bubble growing on a vertical electrode surface is provided in Figure 5.
Figure 5. Schematic of the forces acting on a bubble.
Buoyancy Force (Fb): Originating from the density differential between the gas and liquid phases, this force is directed vertically upward. It acts as the dominant detaching force on horizontal electrodes and serves as the primary driving force for bubble sliding on vertical electrodes.
Hydrodynamic Force (Fh): This encompasses the quasi-steady drag force (Fqs) induced by the relative fluid velocity, and the shear lift force (FSL) generated by the velocity gradient. The drag force acts in opposition to the relative velocity; in quiescent liquids, it typically impedes detachment or sliding, whereas in forced convection, it propels the bubble. The shear lift force is generally directed outward, perpendicular to the wall, thereby promoting detachment.
Contact Pressure Force (Fcp): Because the bubble is not entirely enveloped by liquid, a pressure equilibrium between the internal bubble pressure and the basal contact area generates a net thrust. This overpressure at the contact interface yields a force that pushes the bubble away from the wall [92,93].
Surface Tension Force (FS): Arising from the gas–liquid interfacial tension at the triple-phase contact line, this force acts tangentially downward along the contact line and constitutes the primary resistance to bubble detachment.
Unsteady Drag Force/Growth Force (Fdu): During rapid volumetric expansion (i.e., a high expansion rate), the accelerating bubble must simultaneously accelerate the surrounding fluid. This generates an inertial resistance, typically manifesting as a pressure directed perpendicularly toward the wall.
Marangoni Force (FM): This tangential force is induced by surface tension gradients across the bubble interface, which can be triggered by temperature, concentration, or pressure gradients [94]. Gradients in temperature induce the thermal Marangoni force (or thermocapillary effect, Fthermal), while concentration gradients generate the solutal/concentration Marangoni force (Fconcentration). Yang [95] first experimentally verified the presence of the thermocapillary effect during electrolysis, noting that the temperature gradient originates from localized Joule heating. Subsequently, Park [91] discovered that dissolved gas concentration gradients induce a solutal Marangoni force. The thermal Marangoni force consistently acts to pin the bubble to the electrode, whereas the direction of the solutal Marangoni force varies depending on the specific electrolyte species.
Electrostatic Force (Fe): The presence of the electrical double layer and the adsorption of ions (e.g., H+) at the bubble interface imbue the bubble with a net charge, leading to electrostatic interactions with the charged electrode. The direction of this force is highly variable, as it is strictly dependent on the polarity of the surface-adsorbed charges and the electrode potential; thus, the force vector shifts across different gas species and electrolyte environments.
Consequently, the net force acting upon an evolving bubble on the electrode surface is expressed as
∑ F → = F → b + F → qs + F → SL + F → cp + F → s + F → du + F → e + F → M
The specific mathematical expressions for each force component are detailed in Table 2 [96,97,98]. A schematic illustration of the forces acting on a bubble growing on a vertical electrode surface is provided in Figure 2.
Table 2. Classification, expressions, and effects of forces acting on electrogenerated bubbles during water electrolysis.
Electrode orientation alters the directional vectors of the acting forces, thereby governing bubble detachment behavior. For a bubble growing on a horizontal electrode, detachment occurs when the net external force is directed vertically upward. Conversely, on a vertical electrode—assuming the positive x-axis is directed vertically upward and the positive y-axis points perpendicularly outward from the electrode—a bubble will detach from its nucleation site and slide along the surface when ΣFx > 0 and ΣFy < 0. If ΣFx < 0 and ΣFy > 0, the bubble detaches perpendicularly from the electrode.
However, given the substantial magnitude disparities among these forces in practical scenarios, kinetic modeling frequently necessitates the omission of negligible terms. Based on specific simplifying assumptions, various bubble detachment kinetic models have been developed to match distinct experimental conditions.
In the simplest scenario—a quiescent flow field where all other forces are neglected, and only the balance between buoyancy and surface tension is considered—Fritz established the bubble detachment radius (RB) model:
R B = 0.0208 θ σ g ρ L − ρ G
However, Lv [99] identified a significant discrepancy between the detachment radius predicted by the Fritz formula and the actual detachment radius of oxygen bubbles generated on planar gold electrodes, with the maximum relative deviation reaching approximately 20%. This highlights the inherent limitations of the Fritz formula for practical predictions. By incorporating the dynamic variations of the triple-phase contact line and the contact angle (θ), the Fritz formula was modified:
R B = 3 4 σ d contact sin θ ρ L g 1 / 3
This modified model successfully reduced the maximum predictive deviation compared to experimental results to merely 4%.
Because practical electrolyzers typically operate under forced convection, Reddy [100] and Li [86] further incorporated flow resistance to establish bubble detachment kinetic models for horizontal and vertical electrodes, respectively. Their models accounted for buoyancy, contact pressure, growth force, drag force, and surface tension. Utilizing this framework, Li accurately predicted the detachment diameter of oxygen bubbles at 0.1 A·cm−2 under high flow velocities, yielding a maximum relative deviation of approximately 4%. These models also effectively elucidate previously observed experimental phenomena: as bubble growth progresses and the diameter becomes sufficiently large, buoyancy eventually overcomes the restraining forces, triggering detachment. Furthermore, the model explains that a larger contact angle (θ) intensifies the downward surface tension (Fs), thereby hindering detachment and consequently increasing the detachment radius (RB).
Nevertheless, relying solely on the aforementioned force balance, Nie [89] discovered that the predicted detachment diameters for photoelectrochemically generated oxygen bubbles on TiO2 nano-array electrodes still deviated from actual measurements. Considering the Marangoni effects induced by concentration and temperature gradients in practical electrolysis systems [58,101], Chen [85] and Nie [89] integrated the Marangoni effect into the detachment kinetics for TiO2 nano-array electrodes. This comprehensive model accurately predicted the surface detachment diameter. Further calculations revealed that the Marangoni force contributes up to 18% of the total restraining force preventing detachment. Building upon this model, Park [91] elucidated how electrolyte species affect detachment: in sulfuric acid solutions, ∂σ/∂c > 0, directing the solutal Marangoni force acting on hydrogen bubbles downward; conversely, in solutions like nitric or hydrochloric acid, ∂σ/∂c < 0, directing the Marangoni force upward. Consequently, bubbles require longer detachment time and achieve a larger detachment radius in H2SO4. For example, at −0.16 V vs. RHE, the detachment diameter in H2SO4 was approximately 210 μm, compared to roughly 100 μm in the other solutions.
As investigations progressed, Bashkatov and Hossain [72,82,83] highlighted the presence of ion adsorption on surface bubbles, necessitating the inclusion of electrostatic forces in detachment kinetics. Bashkatov [82] investigated the detachment kinetics of hydrogen bubbles on Pt microelectrodes. Because the triple-phase contact line is extremely short, surface tension and contact pressure were neglected. The quiescent nature of the flow field allowed for the omission of hydrodynamic forces, and order-of-magnitude analyses indicated the growth force was negligible. Consequently, the model primarily considered three forces: electrostatic, Marangoni, and buoyancy. By numerically simulating and quantifying FM and Fb, the surface charge density of hydrogen bubbles in sulfuric acid was inversely calculated via the kinetic equation as σe = 1.98 × 10−5 C·m−2 (assuming uniform charge distribution). Subsequent analysis revealed that the oscillatory phenomenon of hydrogen bubbles on Pt electrodes is fundamentally driven by the competitive interplay between electrostatic and buoyancy forces. Comparisons between experimental and simulated values demonstrated the model’s high accuracy in predicting oscillation frequency and detachment diameter. Because Bashkatov’s initial model incorporated only three forces, Hossain [83] subsequently refined the framework by reintroducing hydrodynamic and growth forces. This comprehensive model optimized the calculated surface charge density to σe = (2.10 ± 0.10) × 10−5 C·m−2. This result is in excellent agreement with calculations derived from the Grahame equation, definitively underscoring the necessity of incorporating electrostatic forces into electrolytic bubble detachment kinetics.
In summary, existing experimental studies demonstrate that surface bubble detachment encompasses multiple modes, with the detachment diameter and frequency governed by electrode surface properties, current density, electrolyte composition, and flow fields. Furthermore, bubble detachment kinetic models initially derived from boiling processes have been significantly advanced in recent years. Modern theoretical frameworks integrate Marangoni effects and electrostatic forces, enabling accurate predictions of detachment diameters and mechanistic explanations for phenomena such as bubble oscillation. However, current theories fail to account for morphological deformations of non-spherical bubbles during detachment, and the interaction mechanisms between adjacent bubbles or between bubbles and bubble layers remain inadequately understood. These challenges must be addressed by developing more sophisticated characterization methods for detachment, observing detachment behaviors in multi-bubble systems experimentally, and advancing further theoretical derivations. A rigorous understanding of these theoretical foundations is essential for optimizing bubble detachment under the coupled influence of multiple variables, thereby guiding advanced electrode design to promote surface renewal and elevate electrolytic performance.

2.4. Coalescence

Nucleation, growth, and detachment constitute a complete cycle for single-bubble evolution on the electrode surface. However, under elevated current densities and high nucleation site densities, growing bubbles frequently contact adjacent bubbles, thereby triggering coalescence and merging into a larger entity. This phenomenon can abbreviate the bubble growth duration [102], precipitate premature detachment, and consequently alter both the gas coverage on the electrode surface [61] and the bubble size distribution within the two-phase flow of the electrolyzer [103]. Therefore, investigating bubble coalescence is of paramount importance for understanding growth and detachment behaviors in multi-bubble systems, providing essential guidance for regulating two-phase flow development and enhancing overall electrolytic performance [104].
Investigations into the bubble coalescence process originated from experimental observations. Coalescence predominantly occurs during the early stages of bubble growth [105]. By capturing the complete coalescence process of two similarly sized bubbles using a high-speed camera, Soto [106] identified several distinct stages: upon initial contact, a connecting neck forms between the bubbles. Over time, this neck expands and widens, adopting a quasi-cylindrical morphology. Driven by the release of surface energy, capillary waves propagate across the upper and lower hemispheres of the merged bubble, prompting a morphological transition from cylindrical back to spherical, ultimately stabilizing as a single entity. Because residual unreleased energy persists, the newly formed macro-bubble often jumps across the solid electrode surface before eventually detaching or reattaching.
During actual electrolysis, not all adjacent bubbles undergo coalescence. Researchers have discovered that the propensity for coalescence is intricately linked to the type and concentration of the electrolyte. Lessard and Zieminski [107] observed that the addition of inorganic electrolytes suppresses bubble coalescence; for instance, increasing the AlCl3 concentration from 0.03 M to 0.04 M reduced the coalescence percentage from 100% to 75%. The concentration at which coalescence is reduced to 50% is defined as the transition concentration. Further studies revealed that this transition concentration depends on the valence and species of the electrolyte ions. Craig [108,109] noted that certain electrolytes (e.g., HCl, H2SO4, and NaClO3) do not impede coalescence. By categorizing ions into α and β classes, Craig proposed an ion-specific combination rule: solutions exhibit coalescence-inhibiting properties only when both the cation and anion belong to the same class (i.e., α\α or β\β). Mechanistically, the team postulated that specific ion adsorption at the gas–liquid interface alters its intrinsic properties, diminishing the hydrophobic attraction between bubbles and consequently mitigating coalescence [110]. Beyond inorganic electrolytes, Monzon [111] demonstrated during microelectrode HER that organic additives, such as tetraalkylammonium salts (TXA+), also effectively inhibit bubble coalescence. As the TXA+ concentration increases, the coalescence frequency decreases, thereby shifting bubble detachment from a periodic to a non-periodic regime.
Coalescing bubbles can be categorized based on their post-coalescence kinematic behavior. Westerheide [41] observed that jumping only occurs when the two bubbles are of approximately equal size; when a significant size disparity exists, the larger bubble directly swallows the smaller one with no apparent displacement. Advancing this research, Zhang [112] systematically summarized three coalescence behaviors in dual-bubble systems based on experimental observations. The first is coalesce-attach, wherein the large bubble remains adhered to the electrode after absorbing the small bubble. The second is coalesce-jump, where the merged bubble briefly leaps from the electrode surface before reattaching. The third is coalesce-detach, in which the merged bubble oscillates violently on the surface before fully detaching into the bulk electrolyte.
Bubble coalescence and subsequent kinematics involve surface energy release and localized flow field variations, prompting quantitative and mechanistic analyses by various researchers. Based on an energy release analysis during coalescence, Lubetkin [113] initially discovered a direct correlation between the jump height and the pre-coalescence radii of the two bubbles. Specifically, the closer the sizes of the two micro-bubbles (assuming R1 > R2), meaning the radius ratio R1 > R2 approaches 1, the higher the relative jump height of the newly formed bubble. With deeper experimental investigation, Li [114] found that post-coalescence kinematics are governed not only by the radius ratio but also by the ratio of the center-to-center distance (S) to the single-bubble detachment radius (Rd,single). By utilizing R1/R2 and S/Rd,single, the post-coalescence behaviors were systematically categorized: 4.5 < R1/R2 < 7 and S/Rd,single < 0.64 correspond to coalesce-attach; 1 < R1/R2 < 4.5 and S/Rd,single < 0.64 indicate coalesce-jump; and 1 < R1/R2 < 3.2 alongside S/Rd,single > 0.64 trigger coalesce-detach. Regarding the mechanism driving the bubble’s return to the electrode, Westerheide [41] speculated it might involve electrostatic interactions and localized surface tension variations. By analyzing the direction of electrostatic forces and the magnitude relationship between thermal and solutal Marangoni effects, Lubetkin [113] further pinpointed the solutal (concentration) Marangoni effect as the primary driver for the return process. When jumping from the electrode, the bubble perturbs the surrounding flow field, altering the local concentration distribution; the resulting concentration gradient induces a solutal Marangoni effect that forces the bubble back to the surface.
In summary, bubble coalescence is a critical phase in electrolytic gas evolution, directly impacting surface gas coverage and the evolution of two-phase flow within the channels. Existing experimental studies have systematically outlined the surface coalescence process and established classification frameworks for coalesce-attach, coalesce-jump, and coalesce-detach behaviors based on dimensional ratios and spatial distances. Experimental results across various electrolyte environments indicate that factors such as electrolyte composition and concentration significantly dictate coalescence, with the addition of specific electrolytes frequently acting as an inhibitor. However, further advancements in understanding electrolytic bubble coalescence face several challenges. The behaviors and underlying mechanisms of multi-bubble coalescence under dynamic flow conditions remain ambiguous. Future research must design targeted experiments to elucidate coalescence mechanisms within flowing states, thereby optimizing electrode design and elevating electrolytic performance.

3. Two-Phase Flow Characteristics in Water Electrolyzers

Gas–liquid two-phase flow in water electrolyzers differs fundamentally from conventional two-phase pipe flows. The gas phase is not introduced at the inlet; instead, it is continuously generated along the reaction zone starting from electrode surfaces, effectively acting as a wall-distributed source term. As a result, gas generation, accumulation, and transport within the cell are governed not only by bulk advection but also by the bubble life-cycle processes, including nucleation, growth, detachment, coalescence, breakup, and migration. These coupled processes are further modulated by operating conditions, channel geometry, and the physicochemical properties of the electrolyte and interfaces. Consequently, pronounced spatial non-uniformity in phase distribution is typically observed, while along the flow direction the two-phase field evolves in a multiscale, stage-dependent manner. In this section, the characteristics of the internal flow field and phase distribution are summarized, and the influences of key factors on gas transport, electrolyte hydrodynamics, and phase distribution are reviewed.

3.1. Gas-Phase Transport and Liquid-Phase Flow

Bubbles leave the electrode with low initial momentum; their subsequent motion therefore does not depend primarily on inertia but is governed mainly by interphase interactions and the surrounding flow structure. A useful geometric view is to separate gas-phase transport into two coupled contributions: advection along the main flow direction and transverse migration normal to the electrode surface. When these two motions reinforce or compete, they dictate the evolving gas–liquid distribution in space and time and, accordingly, the residence time of the gas phase within the cell. These transport characteristics can be understood more clearly by considering the typical two-phase flow configurations in practical electrolyzers, as schematically illustrated in Figure 6 for both parallel-plate and zero-gap geometries.
Figure 6. (a) Schematic diagram of two-phase flow in a parallel-plate electrolyzer. (b) Schematic diagram of two-phase flow in an electrolyzer with zero-gap configuration.
Along the streamwise direction, bubbles are convected downstream under the combined effects of buoyancy and drag. Within a given streamwise cross-section, pronounced spatial non-uniformity in bubble streamwise velocity has been reported. Using particle image velocimetry (PIV) in a small forced-convection parallel-plate electrolyzer, Kuroda [115] showed that the mean streamwise bubble velocity measured in the channel core was approximately 3–4 times that observed in the near-electrode region. At different streamwise elevations, Abdelouahed [116] quantified the mean streamwise bubble velocity within ~1 mm of the electrode via high-speed imaging; the velocity increased nonlinearly with elevation, rising from ~7 mm·s−1 near the electrode bottom to ~20 mm·s−1 at a streamwise height of ~45 mm. This trend indicates that, as bubbles rise along the channel, the cumulative contribution of buoyancy and the effective drag exerted by the bulk flow are progressively strengthened. In addition, Boissonneau [117] simultaneously measured the streamwise velocities of bubbles and electrolyte in a parallel-plate electrolyzer using laser Doppler velocimetry (LDV), and found that when the current density was below 0.2 A·cm−2, the two-phase slip ratio remained below 1.08, suggesting close-to-flow-following bubble behavior under these conditions.
Bubbles do not migrate normal to the surface simply because they are advected downstream; instead, liquid-phase velocity gradients and local flow micro-structures largely dictate whether they detach and how far they re-disperse into the channel. Variations in local velocity and shear—often changing sharply within a thin near-wall region—reshape interphase forces, including drag [118], lift [119], and wall-lubrication effects [120], and thus set the ease of transverse departure from the electrode and the subsequent redistribution toward the channel interior. Evidence for such transverse behavior has been assembled mostly from imaging-based approaches, because quantitative measurements—particularly systematic statistics—of the electrode-normal migration velocity remain scarce. In a parallel-plate electrolyzer, Krikke [121] reconstructed trajectories via optical visualization and observed that bubbles rise with an oscillatory side-to-side motion while exhibiting a net drift from the near-electrode region toward the channel core. Under an imposed forced convection of 20 mm·s−1, Görtz [122] used improved particle-tracking velocimetry (PTV) to show that the angular spread of bubble-velocity directions broadened from ±30° to ±90°, so that more bubbles acquired nonzero electrode-normal components and the near-wall bubble layer dispersed more effectively toward the channel center. Complementing this picture, Boissonneau [117] reported strong temporal variability in the electrode-normal velocity whose amplitude increased substantially with void fraction, consistent with contributions from bubble-induced turbulence and bubble–bubble interactions to transverse transport. Beyond these momentum-driven mechanisms, Lubetkin [113] suggested that Marangoni stresses—triggered by spatial non-uniformities in concentration, temperature, and electric potential—might also bias electrode-normal migration, although the operating conditions under which this pathway becomes relevant are still not clearly consolidated.
The continuous evolution of gas markedly alters the effective hydrodynamic boundary conditions experienced by the liquid phase in an electrolyzer. The presence of bubbles introduces spatial heterogeneities in density and viscosity, thereby reshaping the liquid-phase velocity profile and shear structure; through this flow-field modulation, bubble transport and phase distribution are in turn affected. Nevertheless, quantitative measurements of liquid-phase hydrodynamics in operating electrolyzers remain limited and have largely focused on streamwise velocity characteristics. In existing studies, Boissonneau [117] measured the streamwise liquid velocity distribution in a membraneless parallel-plate electrolyzer using laser Doppler velocimetry (LDV). It was shown that, with increasing streamwise elevation, the velocity profile gradually evolved from a typical “core-high, near-wall-low” shape at the inlet to a pattern in which the velocities near both sides became slightly higher than that in the channel center at the outlet (Figure 7a), indicating local acceleration induced by bubble buoyancy in the near-electrode region. Using particle image velocimetry (PIV), Görtz [123] further demonstrated that the near-electrode enhancement of the liquid streamwise velocity was strongly correlated with current density: under natural convection, when the current density increased from 0.01 to 0.1 A·cm−2, the near-electrode streamwise velocity rose from approximately 15 to 25 mm·s−1. Görtz [123] further examined the effect of inlet flow rate under the same current density, and the corresponding streamwise liquid-phase velocity distributions on the anode side are shown in Figure 7b. Notably, because the cross-sectional flow rate must be conserved, a pronounced acceleration close to the electrodes is necessarily accompanied by a compensating reduction in the liquid velocity away from the electrodes. Under unfavorable conditions such as low inlet flow rate, this redistribution may trigger localized recirculation [124], which can entrain and retain gas, prolong bubble residence time, and ultimately deteriorate mass transport and operational stability. Moreover, gas-induced liquid acceleration is typically accompanied by elevated shear levels, which can further modify flow fluctuations and turbulent structures [125]. Boissonneau [117] observed that at a current density of ~0.2 A·cm−2, the narrow-gap liquid flow transitioned from a quasi-laminar regime toward a quasi-turbulent state, and regions with distinct fluctuation intensities could coexist within the same cross-section. Via visualization, Aldas [126] reported that near the channel outlet the outer boundary of the bubble layer evolved from relatively smooth to irregular, suggesting intensified flow instability. Consistently, Diehl de Oliveira [127] used PIV to quantify the liquid velocity and vorticity fields and found that both the number and strength of coherent vortical structures increased substantially downstream, reflecting progressive enhancement of turbulence in the downstream region.
Figure 7. (a) Liquid-phase velocity distributions at the outlet of a membraneless parallel-plate electrolyzer between the anode wall (0 m) and the cathode wall (0.03 m) at different current densities (inlet flow rate = 0), redrawn from the data in Ref. [117]. (b) Streamwise liquid-phase velocity distributions on the anode side of a parallel-plate electrolyzer with a membrane at the same current density (0.1 A·cm−2) under different inlet flow rates, redrawn from the data in Ref. [123].
Within the narrow inter-electrode gap, bubbles and liquid motion develop together rather than separately. Bubble generation and migration reorganize the liquid velocity distribution and shear structure, and the resulting hydrodynamics feeds back by steering bubble trajectories, dispersion, and residence time. Despite this coupling, most experiments have quantified the two phases mainly through streamwise velocities and macroscopic distribution features. Electrode-normal velocity components are rarely measured systematically, and an integrated understanding of how gas and liquid transverse motions co-evolve is still missing. These shortcomings stem from the practical difficulty of applying velocimetry and diagnostics in narrow, high-void-fraction gaps, as well as from limited coverage of operating conditions and observation viewpoints. As a result, the interplay among transverse bubble migration, electrode-normal liquid motion, and local turbulent structures remains to be clarified.

3.2. Phase Distribution

Within the confined channels of an electrolyzer, the gas phase is continuously created at the electrode surface and then transported by the bulk flow, while individual bubbles nucleate, grow, coalesce, and break up along the way. The resulting phase distribution sets both the effective conductive cross-sectional area and the resistance to mass transfer and therefore has a direct impact on cell voltage and energy consumption. Because gas generation is localized at the electrodes and the available space is limited, strong non-uniformities appear in two directions: across the electrode-normal cross-section and along the streamwise axis. In what follows, we outline typical cross-sectional patterns, track their downstream evolution, and discuss how key parameters steer these distributions.

3.2.1. Cross-Sectional Characteristics and Streamwise Evolution

As bubbles are continuously generated at the electrode surface, they cannot diffuse into the channel core in a timely manner when transverse transport is limited. Consequently, a strongly non-uniform gas distribution develops across the flow cross-section, characterized by a “bubble-rich near-electrode region” and a “bubble-lean region away from the electrodes”, as shown in Figure 8. Hine [128] observed a 2.4 m-tall alkaline parallel-plate electrolyzer and found that most bubbles remained trapped in the near-electrode region, while only a small fraction migrated laterally toward the channel center and was discharged with the bulk flow. Similar stratification was subsequently reported by Janssen [129], Bongenaar-Schlenter [130], and Weijs [131]; however, due to constraints in measurement resolution and quantitative techniques, void-fraction profiles were not provided. Riegel [132] quantified the effective electrical conductivity of the cross-section using a wire-mesh array and back-calculated the void fraction. At a streamwise position of 0.12 m, the void fraction in the near-electrode region reached ~8% and then decreased rapidly with increasing electrode-normal distance before leveling off, whereas the void fraction far from the electrodes remained below 2% (inlet velocity 0.69 m·s−1; current density 0.625 A·cm−2). Using visualization combined with image processing to reconstruct void-fraction fields in an acidic membraneless parallel-plate electrolyzer, Pang [133] further showed that more than 60% of the gas volume could be accumulated within a narrow layer whose thickness was approximately one-tenth of the interelectrode gap, highlighting the pronounced confinement and localization of the near-electrode bubble accumulation layer.
Figure 8. Normalized void-fraction profiles on the cathode side of a membrane-separated parallel-plate electrolyzer as a function of the normalized distance from the electrode (0: at the electrode; 1: at the diaphragm), where the normalized void fraction is defined as the ratio of the local void fraction to the cross-sectionally averaged void fraction. Scatter symbols: data from Ref. [132] at varying current densities (inlet flow rate = 0.69 m·s−1); dashed lines: data from Ref. [126] at varying inlet flow rates (current density = 0.1 A·cm−2).
As electrolysis proceeds, gas is continuously generated along the reaction zone in the form of a wall-distributed source term and accumulates within the channel; accordingly, the cross-sectionally averaged void fraction typically increases in the streamwise direction. Baker [134] used an insulated resistivity probe to measure impedance at multiple streamwise locations and back-calculated the cross-sectional mean void fraction. In a ~0.45 m-tall parallel-plate electrolyzer operated at a current density of 0.16 A·cm−2, the mean void fraction increased progressively from an approximately zero value at the inlet and reached ~18% near the top outlet, with the rate of increase gradually diminishing downstream. Beyond changes in the mean value, the phase distribution at each streamwise location also evolves. A large body of experimental evidence indicates that the near-electrode bubble layer—formed by densely packed bubbles—often thickens nonlinearly along the flow direction. Void-fraction interface profiles measured by Riegel [132] at multiple streamwise positions showed that the bubble-layer thickness increased with streamwise height, while the void-fraction contrast between the near-electrode and core regions widened concurrently. In the downstream section, elevated local void fraction and more frequent bubble–bubble collisions generally enhance bubble growth, leading to a right-shift of the size distribution toward larger scales. Such growth can be attributed either to coalescence or to mass-transfer replenishment of dissolved gas into bubbles [135]. By processing two-phase images acquired at different heights in a naturally convected alkaline electrolyzer, Abdelouahed [136] reported that, at 0.1 A·cm−2, the mean bubble diameter increased from ~60 μm to ~120 μm with increasing height; given the limited number of observed coalescence events, the size increase was attributed primarily to interfacial gas transfer [136]. Using a 1.5 m-tall visualized alkaline electrolyzer, Zhang [137] found that the mean bubble diameter grew from ~100 μm near the inlet bottom to ~300 μm at the outlet, and suggested that coalescence dominated the size growth. In optical observations of PEM water electrolysis (PEMWE), Dedigama [138] noted that detached bubbles continuously coalesced with newly generated downstream bubbles, producing large characteristic bubbles and a downstream transition from bubbly flow to slug flow. With further increases in channel length, gas-phase connectivity may continue to strengthen, potentially triggering additional regime transitions toward annular flow and related morphologies [16,139]. Possible flow regimes that may occur in the cell channel are illustrated in Figure 9.
Figure 9. Different flow regimes that may occur in the electrolyzer.

3.2.2. Effects of Operating Parameters

Inside an electrolyzer, two-phase behavior can be steered from the outside through a small set of operating knobs. Current density primarily fixes the gas production rate, setting the source strength for bubble populations, while electrolyte flow rate governs convective removal capacity and local shear, which then determine how bubbles are transported and redistributed. Temperature and pressure influence the system along a more indirect pathway: by shifting gas density and interfacial/material properties (e.g., wettability and viscosity), they modify bubble characteristics and, ultimately, the observed phase distribution. The remainder of this subsection reviews these parameter effects in turn.
As the externally imposed load increases, current density first acts simply as a source term: it fixes the gas-production flux per unit electrode area and therefore sets the intensity of the two-phase environment. At low current densities, bubbly flow is commonly observed. Raising current density typically shifts the bubble population itself—larger mean diameters and a broader size spectrum are reported—consistent with strengthened coalescence and enhanced interfacial mass transfer [87,135,140,141,142,143]. Meanwhile, because transverse transport is limited, the additional gas generation concentrates preferentially near the electrodes, thickening the near-wall bubble layer. Riegel [132] quantified this near-electrode buildup, showing that the void fraction increased from ~4% to ~8% as current density rose from 0.15 to 0.625 A·cm−2. At still higher current densities, the near-electrode region experiences both higher local void fraction and more frequent bubble–bubble encounters, which can further accelerate coalescence and predispose the flow to unfavorable downstream regimes such as churn or slug flow [115,138,139]. Regime changes can extend even further: in a straight-channel PEM electrolyzer, Liu [144] observed that when current density reached 2 A·cm−2, slug flow could transition—under certain conditions—into annular flow, where liquid is confined to a thin wall film and hydraulic resistance rises substantially. Despite broad agreement on this load-driven progression, the field still lacks a robust quantitative map linking near-electrode void fraction to regime-transition thresholds across different flow fields and geometric constraints. This missing linkage continues to hamper a mechanistic understanding of two-phase behavior under high-load operation.
Electrolyte flow rate modifies the convective removal capacity and near-wall shear level, thereby affecting bubble detachment, transverse spreading, and downstream discharge, and ultimately reshaping bubble size, void fraction, and bubble-layer thickness. Regarding the detachment size, multiple experiments across different systems have consistently reported that higher flow rates lead to smaller bubbles [145,146,147,148] (e.g., Figure 10). Beyond changing characteristic bubble size, increasing the electrolyte flow rate also enhances bubble entrainment and removal by the bulk flow, which reduces the mean void fraction and suppresses gas accumulation near the electrodes. Studies based on conductivity inversion, visualization, and high-speed imaging consistently indicate that increasing the inlet flow rate not only decreases the overall void fraction in the cell [139,149] but also weakens the pronounced cross-sectional stratification, i.e., a “bubble-rich near-electrode layer and a bubble-lean bulk region.” For example, Bongenaar-Schlenter [130] showed that when the inlet liquid velocity increased from 0.1 to 0.75 m·s−1, the ratio of the maximum near-electrode void fraction to the mean void fraction away from the electrode decreased to ~50% of its original value, yielding a more uniform gas distribution. It should be noted, however, that a reduction in void fraction and its spatial homogenization does not necessarily imply a monotonic change in bubble-layer morphology. When focusing on gas-structure metrics, some studies have suggested that the effect of inlet flow rate on bubble-layer thickness can be non-monotonic. By comparing two-phase images acquired at different inlet flow rates in a membraneless electrolyzer, Pang [133] found that the bubble-layer thickness first decreased and then increased as the flow rate rose. Hadikhani [150] further reported for an acidic membraneless parallel-plate electrolyzer that, although a high inlet flow rate helps reduce the overall void fraction, it may over-disperse the bubble layer and increase the risk of gas crossover. Overall, existing work has established the beneficial role of electrolyte flow rate in promoting bubble detachment and removal; nevertheless, the underlying mechanisms by which flow rate controls bubble size, void-fraction distribution, and bubble-layer morphology remain strongly dependent on electrolyzer configuration and operating conditions.
Figure 10. (a) In situ bubble images acquired at the same current density (0.003 A·cm−2) under different electrolyte flow rates [147]. (b) The bubble-size distributions obtained from statistical analysis under different electrolyte flow rates [147].
Pressure and temperature are important operating variables for regulating two-phase conditions in electrolyzers. As pressure increases, gas density rises and bubble volumetric expansion is suppressed, which typically reduces the void fraction and alters the bubble detachment scale. Using in situ high-speed imaging on a photoelectrochemical water-splitting platform, Luo [151] found that when the pressure increased from 0.04 to 0.097 MPa, the mean oxygen-bubble diameter decreased by ~15–20% across different illumination intensities. Based on conductivity-derived void fractions in an alkaline electrolyzer, de Jonge [152] further showed that increasing the pressure from 0.007 to 0.102 MPa led to a marked decrease in the overall void fraction on both the hydrogen and oxygen sides, which was primarily attributed to the reduced bubble volume under elevated pressure. Because in situ visualization and quantitative imaging become more challenging under variable-pressure operation, direct evidence linking pressure to flow regimes and detailed phase-distribution characteristics remains relatively limited.
Only a small number of experiments have examined temperature effects on two-phase behavior. At present, the reported trend of bubble size with temperature remains inconsistent, likely because differences in experimental systems, electrode configurations, and flow conditions make it difficult to isolate temperature effects from the coupled influences of temperature-dependent properties and interphase interactions. Some studies reported larger bubbles at higher temperatures [139,153], which may be related to changes in gas density. In contrast, Ham [154] showed that increasing temperature reduced gas saturation within PTL pores and shifted the bubble-size distribution toward smaller scales, potentially due to enhanced wettability at elevated temperature. Accordingly, the mechanisms by which temperature governs bubble behavior in electrolysis systems still need to be clarified under more controlled and systematic conditions. Beyond bubble size, temperature also plays an important role in the overall two-phase state and void-fraction evolution. Selamet [155] quantified the bulk void fraction in a PEM electrolyzer using combined optical and neutron imaging, reporting an increase from 30% to 35% as temperature rose from 25 °C to 40 °C, which was attributed to decreased gas density and surface tension at higher temperatures. Ham [154] noted that a higher overall void fraction at elevated temperature may coincide with the onset of slug flow, potentially associated with accelerated nucleation and faster bubble detachment/coalescence at PTL–flow-field interfaces. Overall, temperature affects bubble detachment by modifying electrolyte properties and interfacial characteristics, while also regulating gas evolution within channels and porous media, thereby influencing two-phase flow behavior.

3.2.3. Effects of Structural Parameters

The electrolyzer geometry prescribes the fundamental boundary conditions for two-phase flow and, by reshaping the internal flow field, governs bubble generation, transport, and local accumulation. Key structural parameters that control phase distribution include the channel gap, channel configuration, and local flow-disturbance designs. The channel gap sets the gas-holding capacity of the flow passage and the degree of confinement of the bubble layer. Channel configuration determines the global electrolyte flow path and the distribution of low-velocity zones, thereby influencing bubble migration and removal. Local disturbance features can destabilize the near-wall bubble boundary layer by enhancing near-wall momentum and mass transfer, which facilitates gas disengagement and improves gas removal. The following subsection discusses how these structural parameters affect phase-distribution characteristics in electrolyzer systems.
Channel gap directly governs the degree of geometric confinement and the characteristic transverse-transport length scale, thereby controlling the available space for bubble holdup, gas-removal pathways, and the cross-sectional phase-distribution morphology. It is therefore a critical design parameter that shapes two-phase flow structures in electrolyzers. In practice, reducing the channel gap shortens ionic transport distances and lowers ohmic losses; accordingly, compact architectures such as micro-gap, zero-gap, and membrane–electrode configurations have been widely adopted to improve electrolysis efficiency. However, gap reduction simultaneously amplifies gas-occupancy effects, making the generated gas more prone to accumulate within the confined space and steepening void-fraction gradients, which can substantially alter two-phase behavior. Nagai [156] reported that, at high current densities (>0.6 A·cm−2), decreasing the gap to 2 mm led to a recovery (increase) in cell potential, which was mainly attributed to a pronounced rise in void fraction within the narrow passage and the resulting reduction in effective conductivity. Beyond increasing the mean void fraction, a smaller channel gap can also promote earlier transitions in flow regime [157]. In a PEM water electrolyzer, Liu [144] compared channel gaps of 0.8 and 1.3 mm and observed that, under the narrower-gap condition, the bubbly-to-slug transition occurred further upstream. In zero-gap designs, where mesh electrodes are pressed against both sides of the separator, bubbles can be partially guided to disengage along the outer side of the electrodes, thereby alleviating gas accumulation between electrodes [158]. Nevertheless, Haverkort [159] suggested that a zero-gap configuration may favor the formation of a difficult-to-remove gas film between the electrode and diaphragm, and proposed that introducing an electrode–diaphragm spacing of ~0.2 mm could facilitate gas evacuation and reduce the cell potential. Testing this hypothesis, Dung [160] measured gas distributions on both sides of the diaphragm for zero-gap and micro-gap (0.1–0.3 mm) configurations but found no clear evidence of trapped gas films. This discrepancy implies that assembly procedures, interfacial contact conditions, and related factors may strongly influence gas retention within ultrathin gap regions.
To regulate two-phase behavior in electrolyzers, a range of channel configurations has been proposed, including parallel manifolds, single-serpentine, and multi-serpentine layouts. Under the same total inlet flow rate, Ito [161] reported that the pressure drop in a single-serpentine channel increased from ~10 kPa at j = 0 to ~22 kPa at j = 1 A·cm−2, whereas the pressure drop in parallel channels remained below ~1 kPa. This contrast was attributed to the higher superficial velocity and longer flow path in the single-serpentine design, while the parallel layout exhibited much lower pressure losses because each individual channel carried a smaller flow rate and was shorter. Although the low-pressure drop of parallel channels is beneficial for reducing pumping power, it may also weaken gas removal and interfacial liquid replenishment. Lin [162] noted that, at high current densities, insufficient liquid flow in each parallel channel can limit bubble entrainment, and the small pressure differential is unfavorable for electrolyte penetration into the porous transport layer (PTL), thereby exacerbating local mass-transport limitations. By comparison, single-serpentine channels provide a stronger streamwise driving force, but they can more readily promote unfavorable gas morphologies. Majasan [139] reported that long gas slugs occur more frequently in the downstream region of serpentine channels and can hinder water supply, leading to elevated cell potential. Visualization by Trabold [163] further showed that gas plugs are prone to be trapped in bends of serpentine channels and are difficult to purge by the main flow, which can induce localized mass-transfer losses and increase the risk of performance fluctuations. In a visualized PEM electrolyzer, Yi [15] quantified bubble sizes at different serpentine locations and showed that the characteristic size of long gas slugs does not increase monotonically downstream. For example, at j  = 1 A·cm−2 with a water stoichiometry of 15, the initial mean size was ~1.25 mm near the inlet, increased along the path to a maximum of ~2.2 mm, and then gradually decreased to ~1.5 mm, reflecting a competitive balance between coalescence and shear-induced breakup under flowing conditions [15]. Overall, parallel channels offer low pressure losses but are more susceptible to gas-removal and liquid-replenishment constraints under high loads, whereas single-serpentine channels provide strong driving forces but suffer from gas trapping in bends and resulting maldistribution. Multi-serpentine designs are therefore often adopted as a compromise: by shortening the flow path of each channel and reducing bend-induced holdup, they can balance pressure drop against two-phase distribution uniformity [164].
Local flow-disturbance features (e.g., pin ribs, hemispherical protrusions, and spacer meshes) enhance near-wall perturbations and transverse exchange, thereby modifying bubble detachment, redistribution, and downstream removal, and ultimately reshaping the two-phase structure inside the cell. By introducing pin ribs into an alkaline water electrolyzer, Huo [165] observed that the gas morphology shifted toward a finer, mist-like dispersion. A comparative study by Minnaar [166] further showed that the water content in a pin-rib channel was ~1.42 times that in a parallel channel, accompanied by a more uniform water-layer thickness as well as more homogeneous current-density and temperature fields, indicating improved in-plane transport uniformity induced by the disturbance structures (Figure 11). Toward commercially relevant configurations, Wang [167,168] conducted visualization experiments on corrugated bipolar plates equipped with different disturbance patterns and found that, compared with flat plates, newly proposed wedge- and diamond-shaped features enhanced lateral flow-distribution capability by up to 75% and 57%, respectively, relative to conventional concave patterns, thereby reducing the overall cell voltage. It should be emphasized that although disturbance structures can markedly reduce local peak void fraction and suppress gas blockage, they almost inevitably introduce additional pressure losses. For instance, Rivera [169] compared an empty channel with a mesh-filled channel and reported that the spacer mesh improved flow distribution and increased the local Reynolds number at the inlet and outlet to approximately twice that of the empty channel, but at the cost of an additional 2–6-fold increase in pressure drop.
Figure 11. False-color maps of water-layer thickness obtained by neutron radiography for the (a) parallel channel and (b) pin-rib channel [166]. Copyright 2020, American Chemical Society.

3.2.4. Effects of Physical Property Parameters

Gas evolution in electrolyzers is rooted in the physicochemical state of the electrolyte and the characteristics of the electrode interface, which together imprint the resulting two-phase flow structures. On the liquid side, electrolyte concentration and composition tune viscosity, surface tension, and ionic strength, leading to changes in bubble-rise dynamics, coalescence behavior, and interfacial stability. On the solid–liquid–gas interface, wettability and microscale morphology influence contact-line pinning and dewetting, thereby setting nucleation density, detachment size, and bubble wall coverage. These interfacial-level controls propagate upward: they reshape bubble-size distributions and local interphase interactions and eventually determine the bulk void fraction and how non-uniform it becomes across the cross-section. The rest of this subsection discusses these links in detail.
Electrolyte concentration and pH conditions modify viscosity, surface tension, and interfacial effects, thereby altering bubble detachment modes and generation frequency and, in turn, regulating phase-distribution characteristics inside the cell. Zhang [88] reported that in KOH solutions of increasing concentration, the mean hydrogen-bubble diameter decreased from 1.08 mm to 0.24 mm as the concentration rose from 0.5 M to 4.0 M. In water electrolysis experiments using Na2SO4 solutions, Wang [170] found that increasing the electrolyte concentration from 0 to 1 M increased the mean bubble detachment frequency by approximately sixfold, while reducing the mean bubble diameter by 36%. Beyond concentration effects, electrolyte acidity/alkalinity can also markedly influence gas distribution. By comparing acidic and alkaline electrolysis, Kiuchi [171] showed that a 0.1 M H2SO4 electrolyte tended to produce larger hydrogen bubbles (≈0.5 mm) with higher contact angles, thereby enhancing local gas coverage, whereas a 2 wt.% KOH electrolyte generated smaller (<0.2 mm), more spherical hydrogen bubbles, which was favorable for reducing near-electrode gas coverage.
The wettability of electrodes and adjacent porous structures modifies capillary pressure and relative permeabilities within pores, thereby directly governing gas occupancy patterns and evacuation pathways in the near-interface region and constituting a key interfacial factor for tuning two-phase distribution. Under highly wetting conditions, bubbles detach more readily and the solid surface is more easily re-wetted by the liquid phase, which suppresses gas holdup within porous media. Zhao [172] tailored the surface of a Ti porous transport layer (PTL) in a PEM electrolyzer and, combining neutron imaging with electrochemical diagnostics, compared two-phase distributions under different wettability levels. A higher wettability reduced the anode-side gas saturation in the PTL by ~45% and improved liquid-water transport, thereby mitigating mass-transport polarization at high current density (5 A·cm−2). In contrast, under low-wettability conditions, the gas phase is more prone to form a continuous occupancy within the electrode or porous structure and to dominate local pore space. Iwata [13] showed that as the overall wettability of a porous electrode decreased, the pore occupancy shifted progressively from liquid-dominated to gas-dominated, leading to higher concentration overpotential. By introducing locally hydrophobic regions in a PEM electrolyzer, Yang [173] further suggested that localized low wettability can provide preferential gas-release pathways within the PTL, reducing the mean gas saturation by approximately 50%.
Overall, electrolyte properties and material wettability jointly regulate bubble generation, detachment, and rewetting, and together shape gas-occupancy morphology and its spatial non-uniformity across pore and channel length scales. However, most existing studies have focused on individual property or interfacial parameters; their synergistic effects and quantitative characterization across operating regimes remain to be further developed.

4. Two-Phase Hydrodynamics in Electrolyzers

Gas–liquid two-phase flow in water electrolyzers exhibits pronounced multiscale spatiotemporal features. Bubbles are continuously generated at electrode surfaces and evolve through strong coupling with flow, mass transport, and electric-field processes, making it difficult for experiments alone to resolve phase distributions and dynamic mechanisms consistently across all relevant scales [12]. Numerical simulation has therefore become an essential tool for elucidating two-phase structures and governing mechanisms in electrolyzer systems. Existing modeling efforts have primarily focused on two-phase transport and non-uniform distributions in the interelectrode gap and flow channels. By contrast, simulations addressing gas–liquid occupancy and evacuation within porous transport layers or porous electrodes remain relatively limited, leaving substantial room for further development [8].
In numerical simulations of two-phase flow in water electrolyzers, selecting an appropriate mathematical framework and clearly specifying the underlying assumptions are prerequisites for ensuring accuracy and reliability. Different models emphasize different aspects of gas–liquid interaction, interfacial dynamics, and multiphysics coupling, and they vary substantially in complexity and computational cost. Model choice therefore directly determines the attainable fidelity, the required resources, and the level of physical insight that can be extracted for processes inside the cell. A well-chosen model can approximate the relevant physics as closely as possible at an acceptable computational expense, thereby providing a sound theoretical basis for electrolyzer design and optimization. To date, a range of numerical approaches has been developed for two-phase flow in water electrolyzers, most commonly including the mixture model, Eulerian–Eulerian model, Eulerian–Lagrangian model, volume-of-fluid (VOF) model, and immersed boundary method (IBM).
In this section, the key assumptions and solution procedures of these models are first summarized. Their development and applications in water electrolysis are then reviewed, followed by a synthesis of the two-phase flow characteristics and parameter dependencies revealed by numerical results.

4.1. Mixture Model

The mixture model is built on a local-equilibrium assumption, in which a multiphase flow is treated as a pseudo-continuum composed of interpenetrating phases. It is assumed that, over sufficiently small length scales, interphase coupling relaxes rapidly to dynamical equilibrium; consequently, all phases share a common pressure field [174]. Under this framework, separate momentum equations for each phase are not solved. Instead, the averaged motion of the mixture is computed, while relative motion between phases is still permitted through slip velocities [175]. For water-electrolyzer simulations, when the primary interest lies in macroscopic electrolyte circulation and bubble-induced changes in the effective density—rather than the transient interfacial topology of individual bubbles—the mixture model offers a practical compromise between physical representativeness and computational efficiency.
In mathematical terms, mixture density, velocity, and viscosity are defined as volume-fraction-weighted quantities. The momentum equation retains a form analogous to the single-phase Navier–Stokes equations, but correction terms must be included to account for momentum-flux contributions arising from relative motion between phases; these terms are commonly closed using a drift-flux formulation or an algebraic slip relation. For electrolyzer two-phase flows, bubbles are often assumed to be rigid and spherical, while coalescence and breakup are neglected, such that buoyant rise and migration are represented through a prescribed slip velocity. Gas generation by electrochemical reactions is incorporated into the volume-fraction transport equation as a source term or a boundary flux, and the gas production rate is linked to the applied current density via Faraday’s law.
Early studies were constrained by limited computational resources and therefore often relied on reduced-order formulations to capture the essential flow features. For a single vertical gas-evolving electrode under strong buoyancy, Dahlkild [176] employed a boundary-layer approximation and reduced the original two-dimensional mixture model to a bubble boundary-layer problem developing along the electrode, enabling the dominant characteristics of bubble-induced flow and void-fraction distributions to be captured in a dimension-reduced manner. Building on this work, Wedin [177] applied the model to two-dimensional channel flow and abandoned the boundary-layer assumption. By numerically solving the full mixture-momentum equations, natural-convection recirculation driven by gas evolution was resolved, together with its dependence on channel scale, current density, and bubble size. With improved computing capability, the mixture model has been extended to three-dimensional and more complex structures. Nie [178] conducted three-dimensional simulations of the anode-side flow-field plate in a proton-exchange-membrane (PEM) electrolyzer, solving the conservation equations on the full 3D geometry. The results revealed gas-evolution-induced local velocity distortions and recirculation in channel corners and manifold regions. The relative motion was closed using an algebraic slip model, mainly accounting for a drift velocity derived from buoyancy–drag balance, while lateral migration of bubbles in non-uniform shear flows was not included. Within the mixture-model framework, Schillings [179] implemented multiple slip-velocity relations. In addition to the primary slip term based on Stokes drag balanced by buoyancy, shear-induced diffusion, shear-induced migration, and hydrodynamic self-diffusion terms were incorporated. These closures, derived from theories of suspended-particle flows [119,180,181,182], highlight the importance of hydrodynamic bubble–bubble interactions in high-shear regions, enabling more realistic predictions of the lateral spreading of bubble plumes near walls and the evolution of plume thickness.
A major advantage of the mixture model is its low computational cost. In water electrolysis, it is particularly suitable for elucidating how two-phase flow influences macroscopic observables, such as trends in bubble-layer thickness, recirculation flow rate and pressure drop in narrow-gap channels, void-fraction-dependent electrochemical performance, and for screening structural parameters and extrapolating across scales [176,177,179,183,184]. Representative applications of the mixture model in water electrolyzers are summarized in Table 3. Its limitations stem from a strong sensitivity to the selected slip-closure relations and effective-property models. Moreover, the approach is typically predicated on small bubbles that closely follow the liquid motion. As a result, its capability is limited for regimes involving strong interphase nonequilibrium at high void fractions, complex recirculation and transverse migration, as well as phase segregation and structured flow patterns. Consequently, when applied over a broader operating envelope, robust and transferable predictions are often difficult to maintain.
Table 3. Representative simulations of gas–liquid two-phase flow in water electrolyzers based on the mixture model.

4.2. Eulerian–Eulerian Model

The Eulerian–Eulerian model is formulated under a continuum assumption, in which both gas and liquid are treated as interpenetrating, spatially continuous media [187]. Unlike the mixture model, which reduces multiphase flow to a single, mixture-centered momentum field, the Eulerian–Eulerian framework assumes that the two phases overlap within the same computational domain yet retain their own kinematics and thermodynamic states. At any spatial location, each phase is described by its own velocity, pressure field, and thermophysical properties. This formulation is obtained by applying statistical averaging or volume averaging to the instantaneous microscopic Navier–Stokes equations, which filters out the transient fluctuations of the gas–liquid interface and instead resolves the macroscopic evolution of phase distribution [188]. Because local interphase dynamical equilibrium is not imposed, the Eulerian–Eulerian model can cover a broad range of regimes, from dilute bubbly flows to dense bubbly flows. It is particularly suitable for complex, non-uniform flows in water electrolyzers where interphase slip is pronounced and where localized counterflow or large-scale gas–liquid segregation can occur.
When the Eulerian–Eulerian framework is used to solve two-phase flow, separate mass- and momentum-conservation equations are formulated for the gas and liquid phases, and the two phases are linked geometrically through the volume-fraction normalization constraint. The two sets of conservation equations are coupled bidirectionally through interfacial transfer source terms. Physically, these terms represent the mechanisms of momentum exchange across the gas–liquid interface and must be closed to render the model solvable. Accordingly, the force balance acting on bubbles in the electrolyte is represented through interphase momentum-exchange terms, typically including a drag term that captures resistance in the primary flow direction, as well as non-drag contributions—such as lift, virtual mass, wall-lubrication, and turbulence-induced dispersion forces—that account for bubble migration and inertia-related effects. In this macroscopically averaged formulation, the coupled bubble–electrolyte interactions can thus be resolved through appropriately selected closure relations.
Early development of Eulerian–Eulerian modeling for water electrolyzers largely focused on refining and supplementing closures for interphase momentum exchange. Mat [189] constructed the Eulerian–Eulerian model in which bubbles were subjected to buoyancy and drag, but found that lateral bubble migration could not be reproduced. A bubble-diffusion term associated with the void-fraction gradient was therefore introduced to recover the non-uniform cross-sectional void-fraction distribution. Recognizing that bubbles evolve within a turbulent liquid flow field, El-Askary [190] incorporated a turbulence-induced transport term for the gas phase into the Eulerian–Eulerian model, which enabled more realistic prediction of gas accumulation near the electrodes and was used to examine the influence of current density on bubble-layer thickness. Using a two-fluid model for an alkaline electrolyzer, Le Bideau [191] further showed that proper selection of the turbulence model is critical for accurately predicting the bubble-layer width. Although Eulerian approaches are computationally efficient, their accuracy depends strongly on how interphase forces are closed. Dreoni [192] systematically assessed the effects of the thickness of the gas-source region and the equivalent bubble diameter, and showed that both parameters substantially modify the extent and rate of gas dispersion into the channel as well as the vortical structures in the velocity field, thereby affecting agreement with PIV measurements. Under high-load conditions, the elevated near-electrode void fraction can lead to nonphysical gas accumulation. To address this issue, van der Does [186] proposed introducing a solid-pressure-related description to represent short-range interactions within bubble swarms, which suppresses artificial bubble crowding and improves predictive consistency at high current densities.
The Eulerian–Eulerian model substantially improves the representation of interphase nonequilibrium while maintaining a manageable computational cost, and it has therefore been more widely adopted in numerical studies of two-phase flow in water electrolyzers. Representative studies based on the Eulerian–Eulerian model are summarized in Table 4. Separate continuity and momentum equations are solved for the gas and liquid phases, and momentum exchange is introduced through interphase-force models. In this way, interphase slip and the local flow redistribution induced by gas evolution and geometric perturbations can be represented explicitly, yielding a broader applicability to complex flow states than single-fluid formulations [190,193]. On this basis, the approach has been extended to three-dimensional analyses of flow and transport in zero-gap cells and complex flow fields [194,195,196], and can be coupled with electrochemistry to quantify how changes in gas volume fraction or phase distribution affect polarization losses [185,186,194]. Despite these advantages, practical use remains constrained by numerical stability, physical resolution, and the accuracy of closure relations. The strongly nonlinear, tightly coupled equation set increases computational expense and often leads to convergence difficulties. Moreover, because the formulation is inherently volume-averaged, the dispersed phase is homogenized into a continuous field; as a result, neither the microscopic gas–liquid interface nor the discrete identity of individual bubbles can be resolved. This makes it difficult to directly capture topological evolution such as bubble coalescence and breakup, or nucleation and detachment on electrode surfaces. Finally, predictive accuracy is highly sensitive to the selected interphase-force closures. Many available correlations were developed under dilute-bubble assumptions and therefore struggle to represent the complex dynamics of dense bubble swarms at high current densities, which remains a key physical bottleneck for further refinement and high-fidelity application of the Eulerian–Eulerian framework [186].
Table 4. Representative simulations of gas–liquid two-phase flow in water electrolyzers based on the Eulerian–Eulerian model.

4.3. Eulerian–Lagrangian Model

The Eulerian–Lagrangian model treats the electrolyte as a continuum, while bubbles are represented as discrete particles. The liquid phase is assumed to follow continuum mechanics and is solved on an Eulerian grid, whereas the dispersed bubbles are advanced as individual Lagrangian particles moving through the computed flow field [205]. In contrast to the Eulerian–Eulerian model, which relies on volume averaging over the entire domain, the Eulerian–Lagrangian framework preserves the discrete identity of individual bubbles, enabling direct tracking of each bubble’s trajectory and history in time [206]. This model is well suited for probing the evolution of bubble size distributions, localized nucleation and detachment on electrode surfaces, and the mechanisms by which bubble swarms perturb the microscopic structure of the surrounding flow field.
In the Eulerian–Lagrangian model, two-phase coupling is achieved by solving the Navier–Stokes equations for the continuous liquid phase together with Newton’s equations of motion for the discrete bubbles. For the liquid phase, a momentum-conservation equation augmented by an interphase momentum source term is solved, so that the reaction force associated with bubble motion is reflected in the liquid flow field. For the gas phase, bubble dynamics are formulated from Newton’s second law, and the bubble velocity and position are updated by integrating the resultant force, typically including buoyancy, drag, lift, virtual mass, and pressure-gradient forces. Interphase coupling is implemented by accumulating bubble trajectories within Eulerian control volumes and evaluating the corresponding momentum-exchange source terms, thereby incorporating the disturbance induced by bubble swarms into the computed liquid flow field.
In two-phase flow studies of electrolyzers, publications based on the Eulerian–Lagrangian model remain relatively limited. Owing to the computational constraints at the time and an incomplete understanding of bubble dynamics, most early models involved substantial simplifications and inherent limitations. Mandin [207] was among the first to apply the Eulerian–Lagrangian model to electrolyzer two-phase flow, but bubbles were treated as volumeless point particles with a monodisperse size, which hindered accurate representation of bubble-size effects and their influence on the flow field. Nierhaus [208] introduced bubble size as an external input parameter, partially improving the description of size characteristics; however, the force modeling remained simplified, and bubbles were still represented as volumeless points, limiting the realism of two-phase interactions. In the work of Hreiz [12], only drag and buoyancy were included, while other relevant forces (e.g., lift, turbulent dispersion, wall lubrication, and virtual mass) were neglected, making it difficult to capture coupled behavior under complex flow conditions. By contrast, Cao [209] employed a more complete force representation, but the simulations were restricted by computational cost to low-void-fraction and low-current-density conditions, and have not yet been readily extended to higher-void-fraction regimes.
Overall, the Eulerian–Lagrangian model explicitly tracks discrete bubble trajectories within a continuous liquid-phase field, allowing key single-bubble metrics—such as velocity, residence time, and migration pathways—to be obtained directly. This capability provides distinctive advantages for elucidating interphase interaction mechanisms and bubble-induced flow. Representative studies based on the Eulerian–Lagrangian model are summarized in Table 5. With advances in computational power and the development of coarse-graining and parallel computing strategies, the Eulerian–Lagrangian model is progressively overcoming the limitations imposed by early computational resources, making it increasingly feasible to resolve phase-distribution non-uniformity, near-electrode gas enrichment, and their impacts on two-phase transport in electrolyzers with higher fidelity. Nevertheless, under high-void-fraction conditions, accurately representing bubble generation, size evolution, and collective effects while maintaining computational tractability remains an open challenge.
Table 5. Representative simulations of gas–liquid two-phase flow in water electrolyzers based on the Eulerian–Lagrangian model.

4.4. VOF and IBM Models

In two-phase flow simulations, the gas–liquid interface can be explicitly resolved using the volume-of-fluid (VOF) method and the immersed boundary method (IBM) [210,211]. These models abandon the statistical-averaging assumption used in Eulerian formulations and instead aim to capture the transient topological evolution of gas–liquid interfaces directly at micro- or mesoscales. The underlying assumption is that the gas and liquid are immiscible fluids separated by a distinct and continuous physical interface, whose thickness is negligible relative to the macroscopic flow length scales. Within this setting, the computational grid is assumed to be sufficiently fine to resolve curvature variations on bubble surfaces and dynamic contact-angle behavior, enabling a more faithful representation of localized surface-tension effects at the interface. Such models are particularly well suited for mechanistic studies of single-bubble nucleation, growth, coalescence, and detachment on porous electrode surfaces, as well as the detailed hydrodynamics of gas–liquid slug flow in microchannels. However, due to their high computational cost, they are typically applied to small-scale fundamental investigations rather than industrial-scale stack simulations.
The VOF model tracks the interface by introducing a phase volume-fraction scalar field. The transport equation of this scalar is solved to obtain the spatiotemporal evolution of the interface, while a single set of Navier–Stokes equations is solved over the entire domain. Mixture density and viscosity are obtained by volume-fraction weighting, and surface tension is converted into a volumetric source term acting on interfacial cells using the continuum surface force (CSF) formulation. Early studies mainly used the VOF model to resolve gas–liquid interfacial dynamics in channels. Lafmejani [212] investigated two-phase flow in a proton-exchange-membrane (PEM) electrolyzer and, by incorporating a dynamic contact-angle model into the VOF model, reproduced bubble nucleation, growth, and detachment on surfaces as well as the formation of Taylor bubbles. However, the model was restricted to hydrodynamics and did not couple electrochemistry. Wong [213] applied the VOF model to two-phase flow in a zero-gap alkaline electrolyzer, elucidating the transition from dispersed bubbly flow to slug flow and the corresponding gas-volume-fraction distributions. This study likewise emphasized flow physics and did not quantitatively assess how bubble distributions feedback on electrochemical characteristics such as cell voltage. More recently, Zhou [214] established a coupled VOF–electrochemistry model by introducing a Faraday-law-based gas-generation source term into the gas volume-fraction equation, thereby linking local reaction rates to bubble generation. Using this model, the effects of bubble coverage on the effective reactive area and mass-transfer resistance were analyzed under different gas-distribution morphologies, enabling quantification of how gas shielding modulates polarization behavior. Despite its strengths in interface capturing, the VOF model becomes computationally expensive at high void fractions, making it difficult to balance accuracy and efficiency. To address this limitation, Mohsin [193] employed an Eulerian–Eulerian–VOF coupled multifluid model for water electrolysis: VOF was used in regions with sharp interfaces and large-scale phase separation, whereas an Eulerian model was applied in dispersed regions, with local criteria used to switch between models. This strategy substantially reduced computational cost while retaining the ability to capture the impacts of gas generation and bubble accumulation on mass transport and electrical performance at high current densities, thereby extending the applicability of VOF-based modeling for electrolyzer two-phase flows.
In the IBM model, a bubble interface can be represented by a set of Lagrangian marker points. Interfacial stress conditions are coupled through a distributed forcing term in the momentum equations, such that body-fitted mesh regeneration is not required as the interface moves and deforms. Applications of the IBM model to electrolyzer two-phase flow remain relatively limited to date and have mainly focused on microscale single-bubble dynamics and their impacts on near-wall species transport. Sepahi [215] performed direct numerical simulation (DNS) using the IBM model to investigate the growth and dissolution of a single bubble on an electrode surface under buoyancy-driven natural convection. The results showed that solute-concentration-gradient-induced convection markedly altered the structure of the concentration boundary layer and enabled a quantitative linkage between the onset of convection and dimensionless groups such as the Grashof and Rayleigh numbers. Khalighi [216] used the IBM model to simulate single-bubble growth in alkaline water electrolysis; by coupling a dissolved-hydrogen concentration field, the effects of interfacial force balance and contact angle on bubble growth were examined, providing a modeling basis for resolving bubble-scale interfacial processes.
The VOF and IBM models enable explicit resolution of gas–liquid interfacial topology, thereby providing direct numerical evidence for the microscale dynamics of electrolysis bubbles. Representative studies based on the VOF and IBM models are summarized in Table 6. However, these models are highly sensitive to grid resolution and time-step size. Under conditions of high void fraction, strong multi-bubble interactions, or engineering-scale flow channels, they suffer from prohibitive computational cost and intrinsic scale limitations, which restrict their direct application at the level of full cells or stacks. Going forward, multiscale modeling strategies, coupling between interface-resolved and averaged models, and more efficient adaptive meshing and parallel algorithms may allow microscale insights obtained from interface-resolved simulations to be transferred more effectively to macroscopic predictions of two-phase flow and electrochemical performance, thereby strengthening the connection between mechanistic understanding and engineering-scale simulation.
Table 6. Representative simulations of gas–liquid two-phase flow in water electrolyzers based on the VOF and IBM Models.

4.5. Numerical Studies of Two-Phase Flow

Numerical studies of two-phase flow in water electrolyzers are typically built on the incompressible Navier–Stokes equations and solved in a coupled manner with charge conservation, species transport, and reaction-kinetics equations to enable multiphysics simulations [195,216]. Transient modeling of water electrolysis generally requires the coupled solution of the electric field, concentration field, and flow field. Within each time step, the solver first updates the effective electrolyte conductivity based on the void-fraction and concentration distributions from the previous (or initial) state and then solves the charge-conservation equation to obtain the electric-potential field. Next, the local current density on the electrode surface is computed using the Nernst equation and Butler–Volmer kinetics, together with the local overpotential, reactant concentrations, and bubble coverage; this current density is then used to determine the gas flux and the momentum-source boundary conditions. On this basis, the continuity equation, momentum equations, species-transport equations, and the energy equation are solved in a coupled fashion to update the velocity, concentration, and temperature fields. Pressure–velocity coupling is commonly handled using SIMPLE or PISO algorithms [194,214], and convergence within each time step is typically declared when the residuals of continuity, momentum, and key electrochemical variables fall below prescribed thresholds. During meshing, steep gradients of species concentration and electric potential near electrode surfaces and within porous layers generally require locally refined resolution. To balance accuracy and numerical robustness, structured meshes with good orthogonality are often preferred, with local refinement applied in gas-diffusion layers or near reaction interfaces to resolve boundary-layer transport features [200,219]. To ensure solution fidelity, many numerical studies [12,190,191,198] validate their models against experimentally measured liquid velocities and void-fraction distributions, most notably the datasets reported by Boissonneau [117] and Riegel [132]. In addition, model accuracy for electrochemical-performance prediction has also been assessed by comparing simulated and measured current–voltage curves [196,200]. At present, such simulations are commonly implemented in commercial platforms such as ANSYS Fluent and COMSOL Multiphysics [193,202], as well as open-source packages such as OpenFOAM [197,199].
At the channel scale, numerical simulations consistently indicate that buoyancy induced by gas evolution and interphase momentum exchange can markedly reshape cross-sectional velocity profiles. This restructuring is typically manifested as an acceleration of the liquid streamwise velocity near the electrodes, accompanied by a relative reduction in the channel core and, in some cases, the onset of recirculation. Zarghami [198] reported that gas evolution produced an asymmetric profile characterized by a “near-electrode high–core low” pattern. In a parallel channel with an electrode–diaphragm spacing of 8 mm (current density 0.15 A·cm−2; inlet velocity 0.69 m·s−1), the streamwise velocity at 1 mm from the electrode increased by ~15% at a streamwise height of 40 cm relative to the inlet. Under natural convection, simulations by Hreiz [116] predicted an upward streamwise velocity of ~12 mm·s−1 near the electrode, while a downward return flow of ~−8 mm·s−1 developed in the channel center to satisfy cross-sectional flux conservation. With increasing current density, bubble-induced disturbances intensify, and the flow can transition from quasi-laminar toward quasi-turbulent behavior. Alexiadis [197,220] showed that gas evolution can induce secondary-flow structures featuring coexisting upflow and return flow, accompanied by interfacial oscillations and strengthened vortical motions, resulting in more pronounced temporal fluctuations of cross-sectional non-uniformity. Regarding phase distribution, numerical results consistently predict strong non-uniformity within electrolyzers. Simulations by El-Askary [190] for a parallel-plate electrolyzer showed that at a current density of 0.625 A·cm−2 and an inlet velocity of 0.69 m·s−1, the void fraction reached ~11% at the electrode surface and decayed rapidly along the electrode-normal direction to near zero. Aldas [126] similarly reported an approximately exponential decay of the void fraction in the outlet cross-section along the normal direction. Because gas is continuously generated along the flow direction, bubble accumulation forms a bubble layer that thickens progressively downstream. Under a laminar assumption with simplified treatment, Valle [221] suggested that the bubble-layer thickness scales approximately with the 0.4 power of the streamwise height. Schillings [179] further derived, via thermal analogy and dimensionless analysis, empirical correlations involving the Rayleigh and Péclet numbers to predict bubble-layer evolution in parallel-plate electrolyzers.
Furthermore, numerical simulations can probe extreme operating conditions and complex geometries that are difficult to access experimentally, thereby revealing two-phase behaviors inside the cell. Lee [185] simulated a zero-gap alkaline electrolyzer under low inlet velocity (0.01 m·s−1) and high current density (1.5 A·cm−2) and showed that, relative to nominal conditions, the outlet void fraction on the cathode side surged to 66.9%, indicating that severe gas accumulation under extreme operation can markedly impair transport capacity. For high-pressure electrolysis, Liang [203] reported that increasing pressure from 1 to 10 bar reduced the void fraction by at least one order of magnitude (attributed to the reduced bubble volume), but elevated pressure simultaneously weakened bubble-driven natural convection, causing the bubble layer to become more confined near the electrodes and suppressing transport toward the channel core. For commercially relevant complex configurations, Bai [194] simulated water electrolysis in corrugated circular bipolar plates and found that, as the bottom-inlet flow rate increased, the void-fraction pattern evolved from a layered structure toward a dendritic morphology. This result suggests that stronger convection can alleviate bubble accumulation in the central region, whereas bubbles trapped near the periphery remain difficult to remove through flow-rate increase alone. Lu [204] developed a three-dimensional coupled bubble–flow model and further demonstrated that vortices and secondary-flow structures forming in channel corners are key contributors to non-uniform gas distribution; through spatial variations in effective conductivity, these structures were also shown to induce non-uniform current-density fields. These findings imply that global flow-rate control alone is insufficient to eliminate near-wall gas films and localized gas accumulation, and that actively disrupting bubble aggregation via wall-based disturbance features represents an important control strategy. Feng [196] introduced rotating square conductive pillars as disturbance elements in the channel and found that effective gas removal was achieved only at relatively high electrolyte flow rates, whereas under low-flow conditions gas holdup could even be aggravated. Simulations by Wang [167] and Zhang [201] for corrugated hemispherical disturbance structures indicated that gas removal and in-plane distribution uniformity can be improved by altering local pressure, secondary flows, and near-wall shear, although the associated pressure-drop penalty must be accounted for.
Beyond the channel scale, many key non-uniformities in phase distribution originate from near-wall interfacial processes and local phenomena within porous media. These effects therefore require multiphysics coupled simulations at the interface and pore scales to provide complementary mechanistic explanations. At the microscale, in addition to buoyancy-driven motion, Marangoni convection induced by surface-tension gradients can markedly reshape the local flow and mass-transfer environment surrounding bubbles. Studies by Massing [90] and Yang [95] on hydrogen evolution at microelectrodes showed that, at high current densities, ohmic heating at the electrode surface can establish pronounced temperature gradients near bubbles, thereby driving strong thermal Marangoni convection. The corresponding numerical results reproduced micro-vortex-ring structures around microbubbles, indicating that temperature-driven interfacial convection can dominate the near-wall local flow field. For electrolysis systems involving porous media, pore-scale or porous-layer simulations by Li [222] and Lee [185] further suggested that capillary forces and structural heterogeneity can promote localized gas trapping, which restricts liquid percolation and gas-release pathways and thereby becomes a major cause of transport deterioration within porous layers.
Overall, existing numerical studies have begun to elucidate coupling mechanisms spanning macroscopic flow fields and microscopic interfacial processes, as well as the regulatory effects of structural designs on two-phase behavior. Nevertheless, developing high-fidelity multiscale models remains challenging. In particular, closures for key processes—such as bubble coalescence and breakup, near-wall slip, and transport in porous layers—still rely predominantly on empirical correlations. As a result, model transferability across different geometries and wide operating envelopes is limited, leaving substantial room for improving quantitative predictive accuracy and generality.

5. Impacts of Two-Phase Flow on Electrochemical Performance

Two-phase flow in electrolyzers not only reshapes the internal hydrodynamics but also directly defines the thermodynamic and kinetic environment of electrochemical reactions, making it a key factor governing energy efficiency, durability, and operational safety. As schematically illustrated in Figure 12, bubbles can influence electrochemical performance by altering mass transfer, ionic conduction, and the effective reaction area, and their effects are ultimately reflected in the overall electrolytic potential and its individual components. At high current densities, excessive gas accumulation and non-uniform phase distribution introduce substantial additional energy losses, primarily manifested as increases in activation, ohmic, and concentration overpotentials. In addition, two-phase flow induced non-uniform current density distributions and localized hot spots can accelerate spatially heterogeneous degradation of electrodes and separators, thereby compromising long-term durability. Moreover, bubble accumulation near the diaphragm or membrane may even promote gas crossover, creating safety risks associated with hydrogen–oxygen mixing. This chapter discusses these impacts in sequence, focusing on electrochemical voltage losses (activation, ohmic, and concentration overpotentials), component durability, and operational safety.
Figure 12. (a) Schematic diagram of the influence of bubbles on mass transfer, conduction, and effective reaction area. (b) Schematic diagram of the composition of electrolytic potential.

5.1. Activation Overpotential

Gas evolution at electrode surfaces can produce attached bubbles, bubble clusters, or even continuous gas films, thereby locally blocking the electrolyte–electrode contact area. To enable comparison across different systems and electrode morphologies, the gas-phase coverage ( Θ ) is commonly defined as the fraction of the electrode area masked by bubbles. By synthesizing early data for a horizontal electrode in a stagnant electrolyte, Vogt [223] reported that the coverage ratio remained below 0.1 when the current density was <0.01 A·cm−2, but increased rapidly to ~0.4–0.6 as the current density rose to 0.6 A·cm−2. The increase could be approximated by a ~0.3 power-law dependence on current density. It should be noted, however, that practical electrolyzers differ substantially from these idealized conditions in electrode orientation and flow environment; accordingly, both the absolute level of coverage and its operating-condition dependence may shift [224]. Balzer [225] measured a hydrogen-side coverage ratio of only ~0.08 but an anode-side value as high as 0.58 on a vertical nickel electrode under no forced flow (1 M KOH, 0.004 A·cm−2). In contrast, no similarly pronounced asymmetry was observed on copper electrodes, indicating that bubble coverage is strongly governed by interfacial properties such as surface wettability. Upon imposing forced convection, Balzer [225] further found that coverage decreased rapidly with increasing flow velocity before approaching a plateau, and proposed empirical correlations describing coverage as a function of flow speed. For PEM electrolyzers, Xin [226] reported that increasing the water feed rate from 5 to 40 mL·min−1 reduced oxygen coverage on a Ti felt by ~75%. The same study also observed that higher temperature tended to increase coverage, likely due to combined effects of gas-density changes and temperature-dependent wettability [226]. Nevertheless, quantitative measurements of coverage remain challenging. Rox [145] noted that optical determination of coverage near electrodes can be strongly affected by occlusion, scattering, and interference from already-detached bubbles, introducing uncertainty into coverage identification and statistics. Consequently, existing coverage datasets remain limited in both operating-condition coverage and measurement accuracy.
Bubble coverage on the electrode surface reduces the effective electrochemically active area and thereby induces additional voltage losses. For a vertical electrode, Zhang [88] showed that imposing forced convection (Re ≈ 2000) markedly alleviated bubble masking and reduced the cell voltage. The voltage benefit became more pronounced as the current density increased; at 0.25 A·cm−2 in 0.5 M KOH, the convection-induced voltage reduction reached ~0.4 V. The same study also reported that increasing the KOH concentration from 0.5 to 4 M decreased the cell voltage at 0.1 A·cm−2 from ~3.5 to ~2.5 V. Besides the higher bulk conductivity of the concentrated electrolyte, the reduced bubble-detachment diameter and the associated decrease in bubble coverage under high-concentration conditions were identified as additional key contributors to this performance improvement [88]. Using an electrode array positioned at different streamwise locations and decoupling voltage-loss contributions via electrochemical impedance spectroscopy (EIS), Immerz [227] found that the impedance component associated with electrode activity increased from 496 to 564 mΩ·cm2 with increasing streamwise height, indicating a progressively strengthened bubble-shielding effect downstream. For a zero-gap alkaline electrolyzer, Deng [228] quantitatively evaluated bubble effects and reported that, at 0.5 A·cm−2, masking by adhering bubbles could introduce an additional voltage loss of ~26 mV.
The activation overpotential reflects the practical resistance associated with charge transfer at the catalyst surface. When bubbles cover the electrode, the electrochemically active area is reduced, which increases the local current density and thereby amplifies activation losses. Under this condition, the true current density on the electrode surface, j real , becomes higher than the apparent current density, j (i.e., j real = j / ( 1 − Θ ) ). Accounting for bubble coverage, the activation overpotential can be expressed as
η act = a + b log j real j 0 = η act 0 + b log 1 1 − Θ
where a and b denote the Tafel intercept and slope, respectively; j 0 is the exchange current density; and η act 0 = a + b log j j 0 represents the intrinsic activation overpotential in the absence of bubble coverage. The second term on the right-hand side of the second equality corresponds to the additional activation loss induced by bubble coverage.
Based on Equation (13), the activation penalty associated with bubble coverage can be further quantified numerically under different operating conditions. Li [202] introduced a coverage correction within an Eulerian two-phase-flow model and showed that considering flow effects alone while neglecting coverage tends to underestimate the cell voltage in the high-current-density regime by ~10–15%. Cao [209] simulated a parallel-plate electrolyzer with a 20 mm electrode gap and approximated surface coverage using the mean void fraction in the near-electrode region. By quantifying the contributions of bubbles to overpotentials, it was found that, under their simulated conditions, the voltage increase caused by the bubble-induced reduction in effective electrode area was approximately two orders of magnitude larger than that arising from the bubble-induced increase in ohmic overpotential. Ruiz Diaz [229] modeled the porous layers in a PEM electrolyzer and quantified bubble-coverage effects, showing that as gas coverage increased, the activation overpotential attributable to coverage could ultimately account for more than 50% of the total overpotential.
By elevating the true current density, bubble coverage introduces an additional kinetic penalty, making bubble masking a major contributor to activation-overpotential growth at high current densities. However, high-accuracy in situ quantification of coverage—and transferable correlations across electrodes, flow conditions, and electrolyte environments—remain scarce, which limits the reliability of model-based predictions.

5.2. Ohmic Overpotential

Ohmic overpotential in water electrolysis reflects resistive losses during charge transport: ions (and, where relevant, electrons) must traverse conductive media inside the cell, and additional losses can arise from contact resistances at material interfaces. Under the common assumption that electronically conductive components contribute negligibly, the ohmic overpotential associated with current conduction, η ohm , can be written as
η ohm = j ⋅ d gap κ eff + R mem + R contact
where d gap is the geometric conduction distance of the electrolyte; κ eff denotes the effective conductivity. R mem and R contact represent the additional ohmic resistances associated with the membrane (or separator) and interfacial contact, respectively.
Under gas-evolving conditions, the solution conductivity is not determined solely by the intrinsic properties of the liquid phase. Dispersed bubbles, acting as an insulating phase within the electrolyte, reduce the effective conductive cross-sectional area and increase the ohmic resistance. Therefore, a two-phase correction must be applied to κ eff . A common choice is the Bruggeman relation [230], which links the effective conductivity κ eff to the void fraction ε as follows:
κ eff = κ l ( 1 − ε ) m
where κ l is the conductivity of the pure liquid phase, and m is a structural factor that is typically taken as 1.5.
Quantitative evidence for the ohmic penalty induced by two-phase dispersion in electrolyzer electrolytes has been provided by both experimental and theoretical studies. Tobias [134] reported that an overall void fraction of ~30% could reduce the bulk solution conductivity by ~40%. In a vertical rectangular cell, Hine [128] found that increasing the gas-to-liquid flow-rate ratio from 1 to 3 decreased the overall effective conductivity by ~10–20%. It should be emphasized, however, that gas distribution is often strongly non-uniform, such that the overall void fraction alone is insufficient for reliable estimation of ohmic losses. Bongenaar-Schlenter [130] noted that the lack of accurate gas-distribution information limits predictive capability and proposed a two-layer model to fit experimental data. For the near-electrode bubble accumulation layer, Kiuchi [171] placed a reference electrode close to the electrode surface using a bent Luggin capillary and reported an approximately linear relationship between bubble-layer thickness and ohmic impedance. Using simulated void-fraction fields to evaluate the effective conductivity near the electrodes, Mohsin [193] found that when the current density increased to 0.4 A·cm−2, the effective conductivity in the near-electrode region decreased by ~16.9%, suggesting that this region can dominate conductivity degradation. In addition, streamwise non-uniformity of void fraction can also have a pronounced impact on electrolyzer performance. By measuring local current densities at electrodes located at different streamwise positions, Colli [199,219] observed differences of up to 50% between the upper and lower sections. This behavior was attributed to downstream bubble accumulation increasing the ohmic resistance in the upper part of the channel, which forced the reaction current to concentrate toward the lower electrode region where the void fraction was lower.
The discussion above mainly concerns bulk-conduction losses in cells where a finite conductive electrolyte gap remains. With the increasing use of zero-gap and membrane–electrode configurations, the geometric conduction distance of the electrolyte approaches zero, and the contribution of the bulk ohmic term in Equation (14) becomes smaller. Under these conditions, the additional ohmic resistances associated with the membrane and interfacial contacts are more likely to become dominant. Haverkort [159] decomposed the voltage losses of a zero-gap alkaline cell and reported that a micrometer-scale gas film trapped between the electrode and diaphragm introduced an additional voltage loss of ~0.2 V. For a Zirfon diaphragm, de Groot [231] showed that bubble nucleation within diaphragm pores reduces the effective porosity, resulting in an effective resistance (230–500 mΩ·cm2) that is substantially higher than the intrinsic material value (130 mΩ·cm2). For PEM electrolyzers, segmented EIS measurements by Immerz [227] indicated that under high gas-production conditions the ohmic resistance increased by ~45% toward the downstream section of the flow field, which was attributed to local drying effects promoted by gas accumulation. A parametric study by Alkhaldi [232] further identified a critical water-feed threshold in a specific PEM electrolyzer (0.08 mL·cm−2·mL−1). Below this threshold, gas accumulation induces insufficient water supply, leading to local membrane drying, reduced conductivity, and, consequently, severe current-density fluctuations and performance decay.
Overall, conductivity degradation induced by gas presence constitutes a non-negligible contribution to the ohmic overpotential. However, in situ characterization of phase distribution inside electrolyzers remains insufficient, which limits reliable prediction of ohmic losses and robust cross-study comparisons.

5.3. Concentration Overpotential

During water electrolysis, concentration overpotential, η con , arises from limitations in interfacial mass transfer. Electrochemical reactions drive the interfacial concentration of species i, C s , i , far below (or far above) its bulk concentration, C b , i . According to the Nernst equation, this concentration gradient shifts the reversible potential as
η con = R g T n F ∑ i ν i ln C s , i C b , i
where ν i denotes the stoichiometric coefficient of species i in the reaction.
Compared with activation and ohmic losses, direct quantitative studies on concentration overpotential in water electrolysis remain relatively scarce. Available evidence nevertheless suggests that a dense bubble layer increases mass-transfer resistance and thereby amplifies concentration overpotential. By decoupling impedance contributions for a horizontal nickel-wire electrode, Ikeda [233] inferred that the apparent diffusion coefficient of OH− (0.1 × 10−5–2 × 10−5 cm2·s−1) was far lower than its diffusion coefficient in water (5.03 × 10−5 cm2·s−1), and attributed this discrepancy to blockage of OH− transport toward the reaction interface by the bubble layer on the electrode surface. Wang [234] further showed that different surfaces can sustain bubble layers of different thicknesses, leading to distinct mass-transfer impedances at the same current density. At 1 A·cm−2, the bubble-related diffusion impedance was ~180 mΩ·cm2 for a polished surface, but only ~100–120 mΩ·cm2 for a porous DHBT surface; this difference corresponded to a thicker bubble layer (~650–700 μm vs. ~350–400 μm), indicating that a thicker bubble layer can substantially elevate mass-transfer impedance and increase concentration overpotential. Using a VOF–electrochemistry coupled model, Zhou [214] evaluated how different flow regimes affect mass transfer in a PEM electrolyzer and reported that when inadequate flow-field control promotes bubble accumulation into film-like or wavy structures, continuous gas coverage on the PTL can impede electrolyte supply, potentially increasing the concentration overpotential by 1–2 orders of magnitude.
It should be emphasized that the gas phase does not increase mass-transfer resistance solely through volumetric blockage. Under certain conditions, bubble-induced turbulence (BIT) can also enhance mass transfer and thereby reduce the concentration overpotential. However, the competition and coupled effects between these two mechanisms have not yet been systematically clarified. Fouad [235] used K3Fe(CN)6 and K4Fe(CN)6 as redox tracers and reported that the mass-transfer coefficient of K+ increased with gas volumetric flux, exhibiting an approximately log-linear relationship. Subsequent measurements of mass-transfer coefficients under different operating conditions and configurations [236,237,238,239,240] likewise observed bubble-enhanced mass transfer, yet no consensus has been reached regarding the governing trends and mechanisms [9,241]. At present, in situ and direct measurements of solute concentration fields in the near-electrode region and within porous layers remain scarce, making it difficult to quantitatively decouple and validate the relationship between concentration overpotential and bubble-layer structure.

5.4. Durability and Safety

Gas–liquid two-phase behavior in electrolyzers not only reduces instantaneous efficiency through polarization losses, but its non-uniformity and dynamic instability can also trigger mechanical damage, chemical degradation, gas crossover, and even deflagration. These risks collectively threaten long-term durability and operational safety.
Two-phase flow can accelerate electrode degradation and thus shorten electrolyzer lifetime. In long-term tests of an anion-exchange-membrane water electrolyzer (AEMWE), Wu [19] revealed a detrimental “electrode degradation–bubble behavior” feedback loop. First, chemical and electrochemical corrosion led to the accumulation of metal oxides, which increased surface roughness and reduced hydrophilicity. The deteriorated surface properties then hindered bubble detachment and promoted coalescence into larger bubbles (Figure 13), substantially increasing gas connectivity and forming longer slug-like structures. Finally, bubble-induced blockage and the associated deterioration in flow regime can raise the local electrode potential and accelerate corrosion, thereby closing a feedback loop that further aggravates electrode degradation. In PEM water electrolysis (PEMWE), Zhou [242] reported pronounced performance decay in durability tests: after 100 h of operation, polarization behavior deteriorated markedly, and at 50 °C and 2.0 V the current density dropped by up to 58.2%. This degradation was accompanied by thinning, collapse, and crack formation in the catalyst layer near the outlet. It was inferred that bubble enrichment near the channel outlet can strongly impede liquid-water replenishment to the reaction interface, causing local drying and elevated potential, which in turn accelerates catalyst-layer dissolution and corrosion.
Figure 13. (a) Bubble-cluster images before and after surface durability treatment and (b) the corresponding size distributions [19]. (c) The durability treatment helps preserve the surface hydrophilicity against bubble-induced deterioration, thereby suppressing the formation of large bubbles, lowering the electrolysis voltage, and improving voltage stability [19].
In zero-gap or compact electrolyzers, bubbles that are not removed in time and instead accumulate within the narrow electrode–membrane gap can accelerate membrane degradation and markedly increase the risk of gas crossover. Finger [23] reported that dissolution of the Pt coating on the anode side of a PEMWE can lead to Pt deposition within the membrane and subsequent chemical degradation. Gas holdup inside PTL pores was shown to promote spatially non-uniform deposition, likely because locally varying gas concentrations induce differences in current distribution, thereby increasing the risk of membrane penetration at specific locations. Using SEM characterization, Ge [5] elucidated the physical process by which the micro-porous structure of proton-exchange membranes is damaged, as shown in Figure 14. During bubble generation, accumulation, and outward transport within the membrane’s ionomer phase, the original nanoscale pore network can be disrupted; gas escape then produces numerous micrometer-scale voids. The extent of this damage was found to correlate positively with current density, ultimately promoting gas crossover.
Figure 14. Schematic illustration of bubble-induced membrane degradation at low (a) and high (b) current densities [5].
Excessive bubble accumulation in the PTL or flow channels can also sever liquid-water supply pathways, causing local drying at reaction interfaces and potentially triggering deflagration. By combining neutron imaging with X-ray scanning, Maier [243] quantitatively mapped liquid-water distributions in a PEM electrolyzer and found that, at high current densities, non-uniform gas saturation significantly reduced the water-layer thickness at the membrane–electrode interface. Tan [20] reproduced and analyzed the mechanisms underlying deflagration incidents in PEM electrolyzers (Figure 15). It was shown that severe local drying caused by channel blockage can reduce membrane conductivity by up to two orders of magnitude; the resulting localized Joule heating can rapidly raise the membrane temperature beyond 150 °C. This hot-spot effect can soften the membrane, promote thinning and even pinhole formation, ultimately enabling direct mixing of hydrogen and oxygen and triggering deflagration. These findings highlight the critical importance of two-phase-flow management for electrolyzer safety under extreme operating conditions.
Figure 15. In situ images of electrolyzer flashback caused by local dryout at high current density [20].

6. Two-Phase Flow Management and Optimization Strategies

Non-uniform gas coverage on electrode surfaces and gas accumulation within flow channels are key contributors to increased overpotentials, mass-transport limitations, and even safety risks at high current densities. Accordingly, actively managing bubble behavior across relevant length scales has become an important route to improving electrolyzer power density and operational stability. Based on the governing mechanisms of two-phase flow in electrolyzers, this chapter reviews management and optimization strategies from three perspectives: flow-field organization and regulation, surface modification and structural design, and external-field control.

6.1. Flow-Field Organization and Regulation

Bubble dynamics can be improved by shaping the flow environment and tuning operating parameters. This includes establishing convection-enhanced conditions, implementing dynamic regulation strategies, and tailoring electrolyte composition to modulate two-phase behavior, thereby delaying the formation of unfavorable gas morphologies (e.g., gas films and gas plugs) and mitigating bubble-induced masking of the reactive surface.

6.1.1. Flow-Field Architecture Optimization

Optimizing flow-field architecture, together with coordinated multiphysics regulation, can further improve two-phase transport—for example, by suppressing the emergence of unfavorable gas morphologies (e.g., gas films and plugs) and reducing local fluctuations and performance losses. Wu [244] proposed a structured-mesh flow-channel design in which an internal scaffold breaks large bubbles into smaller ones, effectively inhibiting the development of churn-like flow in the channel. Combined with wettability tuning of the channel surface, this design strengthened capillary suction on bubbles and promoted rapid detachment from the porous-layer surface. In follow-up work, the same group [245] addressed the tendency of bubbles to accumulate under ribs in conventional flow fields by developing a dual-layer design with a “bubble self-pumping” function. A hydrophilic porous degassing layer was tightly embedded between the conventional channel and the electrode; driven by a Laplace-pressure gradient arising from wettability contrasts, bubbles were spontaneously extracted from the reaction interface and released into the main channel. This self-managed mechanism, requiring no external energy input, eliminated bubble holdup and blockage at the porous-transport-layer interface and substantially reduced mass-transfer resistance at high current densities. Shi [246] incorporated a shear-based mechanism into the design of a microfluidic hydrogen-evolution reactor. By creating a forced-convection environment with high shear and lift, the bubble detachment radius and residence time were effectively reduced. In addition, Ji [247] proposed a confinement-driven bubble self-management strategy (Figure 16). Using a slit-like channel geometry, buoyancy differences arising as bubbles rise in a confined space were leveraged to induce strong electrolyte self-circulation (“self-pumping”). This passive hydrodynamic mechanism accelerates bubble removal from electrode surfaces and markedly enhances mass-transfer efficiency in compact electrolyzers without pump assistance.
Figure 16. A spatial confinement strategy that utilizes buoyancy-driven bubble transport for self-sustaining hydrodynamic management [247]. Copyright 2025, American Chemical Society.
Leveraging capillarity to induce self-driven hydrodynamic transport has emerged as a new management strategy for enhancing mass transfer. Hodges [248] proposed a capillary-fed electrolysis cell design, in which capillary forces in a hydrophilic porous separator deliver electrolyte directly to the electrodes, allowing the generated gas to enter the gas-collection chamber without traversing a liquid layer. This operating mode eliminates bubble formation on the electrode surface at the source, enabling stable operation with Faradaic efficiencies as high as 98%.

6.1.2. Dynamic Regulation Strategies

Conventional steady-state operation often fails to remove bubbles trapped on electrode surfaces or within porous media. Introducing dynamic regulation has been shown to effectively disrupt the quasi-stationary bubble boundary layer. Bakker [249] developed a periodic pressure-fluctuation technique to address bubble accumulation on electrodes. The underlying principle is that bubble volume expands significantly as the ambient pressure decreases; the resulting rapid volume change perturbs the force balance at the electrode surface and accelerates bubble detachment. Building on this concept, Bleeker [250] applied periodic pressure swings to a zero-gap electrolyzer, where transient gas-volume pulsation was used to purge bubbles retained in pores. For a nickel-foam electrode operated at 1 A·cm−2, a cell-voltage reduction of ~0.1 V was reported.
Beyond direct pressure perturbation, pulsed electrolysis provides an alternative route for regulating bubble dynamics. From a mass-transfer-enhancement perspective, Rocha [251] systematically examined how pulse parameters affect the performance of 3D electrodes and showed that, by decoupling pulse width and duty cycle, bubble residence time within porous structures can be substantially shortened and gas coverage on electrode surfaces markedly reduced. Demir [252] investigated the effect of pulsed potentials on alkaline water electrolysis and reported that the imposed waveform can generate a pumping effect. This unsteady hydrodynamic response not only modifies hydrogen evolution behavior but also enhances anode corrosion resistance by reducing bubble–surface contact time, leading to a 20–25% reduction in overall energy consumption. In addition, Khosla [253] found that pulse parameters influence microscopic bubble size; lower duty cycles tend to produce finer bubbles, which detach more readily from the electrode surface, indicating that dynamic electrical modulation can also deliver meaningful hydrodynamic benefits.

6.1.3. Electrolyte Modification

Beyond macroscopic field regulation, tailoring electrolyte composition and physicochemical properties provides another important route to intervene in interfacial bubble behavior. Using electrochemical oscillations, Park [254] examined how electrolyte species and concentration affect hydrogen-bubble detachment and reported that the coalescence efficiency of microbubbles follows the Hofmeister series. By optimizing electrolyte composition, surface-tension gradients can be tuned, thereby shifting the competition between solutal and thermal Marangoni effects and regulating bubble coalescence.
For electrolyte modification, introducing surfactants offers an active control lever. Hosseini [255] showed that adding trace amounts of ionic or non-ionic surfactants (e.g., SDS and Triton X-100) can markedly reduce bubble specific surface energy and adhesion, increasing the hydrogen-evolution current density by 47–460% at the same overpotential. In oxygen evolution (OER), Xie [256] demonstrated the dual functionality of the cationic surfactant CTAB: it promoted adsorption of OH− on NiFe-LDH electrodes via electrostatic interactions while substantially reducing the bubble detachment diameter, thereby lowering the overpotential by ~50 mV at 0.1 A·cm−2. As a “traceless” regulation strategy, Yang [257] proposed nanobubble seeding, in which nanobubbles are introduced into the electrolyte as pre-existing gas nuclei to lower the supersaturation barrier for macroscopic bubble formation, as shown in Figure 17. This method not only reduced the OER overpotential but also suppressed electrode deactivation under fluctuating renewable power operation by lowering the nucleation threshold and mitigating bubble-growth lag.
Figure 17. (a) Schematic illustration of how the introduction of intrinsically generated and adsorbed surface nanobubbles lowers the local supersaturation required for gas-phase transformation, thereby reducing the associated overpotential [257]. (b) Introducing nanobubbles to improve the OER performance [257].

6.2. Surface Modification and Structural Design

Surface modification and structural design aim to regulate the microscale topology and wettability of electrodes and transport layers, thereby controlling bubble nucleation, growth, and transport pathways at the source and, in turn, shaping two-phase flow behavior within electrolyzers.

6.2.1. Surface Wettability and Biomimetic Design

The microscale morphology and intrinsic wettability of an electrode jointly determine bubble adhesion and detachment kinetics. Accordingly, constructing biomimetic surfaces with tailored wetting states has emerged as an effective strategy to accelerate bubble release. Inspired by pine-tree architectures in nature, Li [258] fabricated a pine-tree-like Pt nanoarray electrode with superaerophobic characteristics. As shown in Figure 18, owing to its hierarchical micro/nanostructure, the solid–liquid–gas three-phase contact area was substantially reduced, decreasing bubble adhesion by ~11.5 μN and enabling spontaneous, rapid detachment at very small bubble sizes. To address bubble retention at high current densities, Ren [259] patterned periodic nanocone features on nickel electrodes. Numerical simulations and visualization experiments showed that the conical geometry effectively alters three-phase contact-line tension, markedly shortening bubble residence time during growth and reducing the detachment diameter. Zhang [260] designed a synergistic electrode consisting of superaerophilic SiO2 stripes (SAL) and superaerophobic Pt clusters (SAB). Driven by asymmetric interfacial tension, bubbles were transported from the SAL region to the SAB region and released within ~2 ms. This SAL/SAB electrode achieved an ultrahigh current density of 1.867 A·cm−2 at an overpotential of only 500 mV. For seawater electrolysis, Liang [261] developed a honeycomb-like 3D cathode structure that uniformly generated abundant micro-sized hydrogen bubbles. The resulting outward convection not only accelerated product removal but also formed a hydrodynamic barrier that effectively hindered Mg2+/Ca2+ ions from approaching the electrode surface, enabling precipitation-free stable operation for up to 1000 h at an industrial-level current density of 1 A·cm−2.
Figure 18. Bubble generation behaviors and the corresponding statistics of the related size distribution for the released bubbles on (a) Pt nanoarray film and (b) Pt flat film [258]. Copyright 2015, John Wiley and Sons.
Beyond the electrode surface, the wettability of the porous transport layer (PTL) is likewise critical. Zhao [172] rendered a Ti-based PTL superhydrophilic; neutron imaging showed that the superhydrophilic treatment markedly reduced gas saturation within the PTL. In particular, at current densities above 5 A·cm−2, this modification mitigated bubble blockage and reduced the cell voltage by more than 11%, indicating that tuning bulk wettability of transport layers can be an effective route to relieving mass-transport bottlenecks at high loads. Recently, mixed-wettability concepts have increasingly been introduced into porous layers. Sheng [262] designed a Janus electrode with asymmetric wettability, in which a Laplace-pressure difference generated by the wetting gradient drove directional “anti-buoyancy” transport of bubbles. Habudula [263] patterned localized hydrophilic/hydrophobic regions on a Ti-felt PTL using a masking method, and showed that partitioned wettability can create relatively independent liquid-supply channels and gas-removal channels; an optimal performance window was observed as the hydrophobic coverage fraction varied. In an AEM electrolyzer, Kang [264] implemented anisotropic wettability in a Ni-foam PTL (e.g., hydrophobic at the top and hydrophilic at the bottom). Experiments indicated that this “directional separation” design can simultaneously maintain stable liquid supply and enhance upward gas evacuation, improving operational stability under high-load conditions. Overall, hydrophilization is better suited for suppressing gas holdup and promoting rewetting inside pores, whereas hydrophobization primarily facilitates rapid gas-release pathways. Mixed-wettability designs, by spatially allocating these functions, can deliver a more balanced and effective two-phase management outcome.

6.2.2. Ordered Architectures and Gradient-Porosity Design

Within porous electrodes, high tortuosity and stochastic blockage inherent to disordered pore networks are major constraints on mass transfer. Accordingly, shifting from disordered to ordered architectures has become an important direction in electrode design. Kou [6] fabricated nickel electrodes with strictly periodic architectures via 3D printing. Comparative experiments showed that, relative to conventional Ni foams with randomly distributed pores, deterministic periodic structures can effectively suppress bubble coalescence and blockage, enabling rapid bubble release even at a high current density of 1 A·cm−2. To address mass-transfer limitations in disordered nanostructured arrays grown on substrates, Kang [265] synthesized vertically aligned parallel nanosheet-array electrodes via a stress-induced method. The aligned architecture provided fast gas-release pathways and delivered a current density of 4 A·cm−2 at a cell voltage of 2.862 V. Inspired by “ridge–furrow” irrigation in agriculture, Peng [266] used a laser-assisted technique to construct vertically through-connected, directionally aligned pore arrays, which spatially separated gas transport from electrolyte imbibition. This ordered structure reduced mass-transfer resistance by 46% and increased the three-phase interfacial area by 96%, achieving a peak power density of 85.5 mW·cm−2—an 82% improvement over conventional electrodes [266].
For bubble transport within porous structures, constructing graded-porosity architectures (graded PTLs) has been shown to effectively guide directional bubble migration. Combining pore-network modeling with experimental validation, Lee [267] designed a graded PTL whose porosity increased through the thickness from the catalyst-layer side toward the flow-field side. This gradient markedly reduced gas saturation and increased liquid-water permeability, because the larger-pore region exhibits a lower capillary pressure and thus provides a low-resistance pathway for gas evacuation, mitigating bubble accumulation at the catalyst-layer interface. In addition, Yang [268] used graded porous structures to promote bubble splitting, enabling large bubbles to spontaneously fragment into smaller bubbles along the transport pathway. The graded porous electrode not only delivered an optimal overpotential of 83 mV with stable operation at 0.01 A·cm−2 but also exhibited the highest electrocatalyst utilization.

6.3. External-Field Control

Beyond hydrodynamic and interfacial forces, introducing external physical fields offers a new, non-contact dimension for managing two-phase flow. Magnetic fields, acoustic fields, and mechanical vibration can impose additional body forces on bubbles, thereby enhancing mass transfer and accelerating gas disengagement.
Magnetic-field regulation of electrolysis two-phase flow mainly relies on the Lorentz force generated by the interaction between electric and magnetic fields. The resulting magnetohydrodynamic (MHD) effects can substantially reshape local flow structures and strengthen mass transfer. Lin [269] reported that applying a magnetic field does not change the electrolyte conductivity; instead, performance improvements primarily arise from accelerated bubble removal. Baczyzmalski [270] showed experimentally that a parallel magnetic field can induce strong shear flow via the Lorentz force, and this shear can overcome surface-tension constraints and promote rapid detachment of individual bubbles at early growth stages. Combining visualization with EIS, Wang [271] further indicated that the Lorentz force can deflect bubbles directionally and drive macroscopic convection in the electrolyte, shortening bubble growth lifetime and reducing detachment diameter, and homogenize ion distributions, thereby decreasing concentration-gradient-induced overpotentials, as shown in Figure 19. Beyond hydrodynamic manipulation, Niether [272] proposed a distinct strategy that uses a high-frequency magnetic field (300 kHz) to heat magnetic catalyst particles. Through inductive coupling, localized micro-heating can be generated without substantially increasing the bulk electrolyte temperature, enabling catalytic sites to reach activity levels comparable to operation at ~200 °C. This effect can markedly reduce activation overpotential, highlighting the potential of magnetic fields for coupled thermal–electrochemical–hydrodynamic regulation.
Figure 19. Bubble migration under the magnetic field [271]. Copyright 2020, American Chemical Society.
Compared with magnetic fields, acoustic fields and mechanical vibration provide a more direct physical intervention for bubble management by introducing high-frequency pressure waves or inertial forcing. Hung [273] applied ultrasound in an alkaline electrolyzer and reported that ultrasonic oscillations accelerated bubble detachment, reducing energy consumption by 15–20%. Cho [274] investigated hydrogen evolution on stainless-steel electrodes under a 20 kHz ultrasonic field and showed that acoustic streaming and the Bjerknes force markedly decreased the bubble detachment diameter and accelerated bubble removal. As a result, the current density increased by ~9% at the same overpotential, indicating a reduced bubble-induced resistance. Notably, ultrasonic effects can differ between gas-evolving reactions. Walton [275] reported that ultrasound at 38 kHz increased the hydrogen-evolution rate by approximately 110%, whereas the oxygen-evolution rate slightly decreased, likely due to accelerated growth of an oxide layer. This observation suggests that, in practical systems, acoustic parameters should be tailored to the distinct behaviors of the cathode and anode to optimize full-cell efficiency.
Beyond magnetic and acoustic fields, applying a hypergravity field is also an effective means of enhancing gas–liquid separation. Using a rotating packed bed to generate centrifugal forcing as a hypergravity analog, Cheng [276] reported a negative correlation between cell potential and the gravity factor. Experiments by Wang [277] further showed that under hypergravity, the bubble detachment force increases by multiples, enabling rapid detachment at small sizes by overcoming surface-tension and viscous constraints. This effect substantially reduced bubble coverage and strengthened mass transfer at the electrode surface.

7. Two-Phase Flow Characterization Methods in Electrolyzers

Gas–liquid two-phase flow in water electrolyzers is highly unsteady and inherently multiscale. Spatial scales span from micrometer-level bubble nucleation and pore-scale transport within porous layers to millimeter- and even meter-scale macroscopic transport in flow channels. The relevant time scales range from millisecond bubble coalescence and breakup to cumulative effects during long-term operation. Accurate characterization of internal two-phase structures, bubble dynamics, and their coupling with electrochemical processes is essential for validating numerical models, optimizing flow-field designs, and elucidating performance-degradation mechanisms. However, the enclosed cell architecture, the optical opacity of porous media, and the shielding effects of dense bubble swarms make it difficult for any single diagnostic technique to resolve the full complexity. This chapter reviews the major two-phase-flow characterization methods used in water electrolysis, focusing on their working principles, multiscale implementations, and technical limitations.

7.1. Microscopic Observation Methods for Gas Evolution

In water electrolysis systems, both the cathodic hydrogen evolution reaction (HER) and the anodic oxygen evolution reaction (OER) are fundamentally accompanied by surface gas evolution, which significantly impacts overall electrolytic performance. An in-depth understanding of bubble dynamics is critical for optimizing electrode architectures and enhancing electrolysis efficiency. However, the rapid (microsecond to millisecond) and microscopic (micrometer to millimeter) nature of bubble nucleation, growth, coalescence, and detachment presents substantial observational challenges. Driven by advancements in optics and spectroscopy, microscopic observation techniques have emerged as essential tools for elucidating gas evolution processes. This section details the principles of various microscopic measurement techniques and their specific applications in water electrolysis research.

7.1.1. High-Speed Optical Microscopy (HSOM)

Optical microscopy currently represents the most mature and widely adopted technique for investigating electrolytic bubble dynamics. Given the exceptionally high growth rates and rapid spatiotemporal variations of bubbles during electrolysis, macroscopic observations or standard industrial cameras (typically <60 fps) can only capture blurred bubble clouds or bulk gas flows, rendering the accurate analysis of individual bubble evolution impossible [278]. By coupling high-magnification optical microscopes with high-framerate CMOS sensors, high-speed optical microscopy (HSOM) enables the capture of microsecond-level bubble dynamics. This facilitates the quantitative analysis of critical parameters, including bubble growth, contact angle variations, and detachment frequency [8,274,279,280,281]. The fundamental research workflow using the HSOM system is illustrated in Figure 20. Based on the gas evolution behaviors captured by the visualization system shown in Figure 20a, image processing algorithms are implemented for bubble identification. This procedure enables the extraction of relevant quantitative information, while the efficacy of the identification algorithm is demonstrated in Figure 20c.
Figure 20. (a) In situ HSOM system for studying bubble evolution on the electrode. (b) Oxygen bubble detection results under varying current densities and wire electrode diameters. (c) Visualization of successful and failed hydrogen bubble detections: red, green, and blue symbols indicate successful, false, and missed detections, respectively [282].
For microscopic observation, experiments predominantly utilize microelectrodes or wire electrodes. Microelectrodes, characterized by their minimal surface area, are typically employed to isolate and study single-bubble growth and detachment. Conversely, wire electrodes, offering larger surface areas, are utilized to investigate detachment behaviors within multi-bubble systems. Because electrogenerated bubbles are typically micrometer-sized, HSOM is essential for accurate recording. Various researchers have employed different electrode geometries to observe gas evolution. Brandon [64] and Park [91] utilized Pt microelectrodes with diameters of 10–100 μm to study the complete lifecycle of single bubbles. They identified three distinct growth stages based on the temporal evolution of the bubble radius and determined that growth velocity is modulated by current density, electrode structure, and external fields. However, due to the relatively low recording framerate (50 fps), data points during the initial growth phase (t < 0.1 s) were sparse. As technology advanced, Bashkatov and Hossain [72,82,83] investigated single hydrogen bubble growth on horizontally oriented 100 μm Pt microelectrodes utilizing an observation system operating at 1000 fps with a spatial resolution of 820 pix·mm−1. Such high spatiotemporal resolution enabled the observation of oscillatory bubble growth phenomena. Beyond microelectrodes, researchers have also employed wire and pseudo-planar electrodes. Liu [87] utilized a horizontal nickel wire (radius 0.1 mm, length 4 mm) to observe hydrogen and oxygen gas evolution. By employing high-power LED backlighting to generate bubble shadowgraphs coupled with an HSOM system, a framerate of 500 fps and a spatial resolution of 213 pix·mm−1 were achieved. These observations demonstrated that an increase in current density correlates with an increased detachment diameter and a reduced detachment frequency. Wang [71] employed a nanostructured TiO2 electrode; because the generated bubbles were significantly larger than the surface nanorods, the substrate was approximated as a planar electrode. Consequently, a camera with a resolution of 1376 × 1040 was utilized to record oxygen bubble growth from a lateral perspective.
Image data acquired via optical microscopy necessitates further processing to extract bubble dimensional characteristics and dynamic trends. Automated image processing algorithms are conventionally employed to rapidly identify bubbles and calculate their characteristic dimensions. Current research predominantly focuses on optimizing traditional algorithms and leveraging deep learning. Addressing the limitations of the traditional Watershed algorithm, Peng [283] proposed a novel segmentation strategy based on optimized markers and edge constraints. By introducing edge operators to extract bubble boundaries as prior constraints, segmentation bias was significantly reduced, achieving an average Rand Index (RI) of 92.88%. Nevertheless, the efficacy of traditional algorithms remains suboptimal under high current densities characterized by dense bubble coverage. The introduction of Convolutional Neural Networks (CNNs) has drastically enhanced bubble detection accuracy. Toyama [282] developed a detection and tracking framework based on Faster R-CNN, achieving high-precision identification of hydrogen and oxygen bubbles with an F1 Score exceeding 0.90. To address the challenges of measuring bubbles within the ultra-narrow gaps of parallel-plate electrolyzers, Görtz [141] applied Mask R-CNN for instance segmentation. This approach enabled not only precise bubble localization but also the accurate delineation of irregular bubble contours, facilitating the calculation of equivalent diameters. Furthermore, Matthews [284] applied the YOLO series (v5, v7, v8) models for oxygen bubble detection in PEM electrolyzers, discovering that YOLOv7 maintains high precision while offering rapid inference speeds suitable for online monitoring. However, the performance of deep learning models is heavily reliant on the volume of annotated training data, and the labor-intensive nature of manual annotation remains a primary bottleneck for widespread application.
In summary, HSOM is an indispensable tool for investigating electrolytic bubble dynamics. Current equipment is highly mature, offering exceptional spatiotemporal resolution. When integrated with advanced image recognition algorithms, critical information such as bubble size and contact angle can be accurately extracted. However, HSOM is fundamentally limited to two-dimensional projection, precluding the direct acquisition of 3D bubble evolution within the flow field. Secondly, constrained by optical resolution limits, visualizing nanoscale nucleation processes remains unfeasible. Finally, accurate bubble identification under industrial current densities with high surface coverage continues to pose a significant challenge.

7.1.2. Laser Interferometry and Digital Holography

Although HSOM provides substantial data regarding bubble evolution, its reliance on 2D projections obscures critical information, such as the microscopic structure at the bubble base and the bubble’s spatial position within a 3D volume. Furthermore, during the early stages of nucleation and growth, an ultra-thin electrolyte film—the microlayer—exists between the bubble and the electrode. The thickness of this microlayer typically ranges from micrometers down to nanometers, rendering it unmeasurable by standard optical microscopy. To overcome the limitations of 2D imaging, researchers have introduced measurement techniques predicated on the wave nature of light (interference and diffraction): Laser Interferometry and Digital Holography [284,285].
Laser interferometry operates on the principle of thin-film interference. By utilizing high-speed cameras to record the dynamic temporal evolution of interference fringes, the 3D morphology and evolution of the microlayer at the bubble base can be reconstructed [279]. Digital holography involves passing light through the bubble-laden electrolyte, causing the object beam to interfere with a reference beam on a CCD/CMOS sensor to form a hologram. Subsequently, numerical algorithms—such as the Fresnel diffraction integral or the angular spectrum method—are employed to extract the 3D coordinates (x, y, z) and characteristic radii of the bubbles.
Employing these advanced techniques, researchers have conducted targeted investigations into surface gas evolution during water electrolysis. Wang and Shen [279,286] utilized synchronized laser interferometry and high-speed photography to microscopically observe the microlayer. Two laser beams reflected from the upper and lower surfaces of the microlayer were optically magnified and recorded by a CCD. The results revealed that the microlayer beneath the bubble is not a uniform film; rather, it exhibits a wedge-shaped profile—thinner at the center and thicker at the periphery—with an initial thickness of approximately 10 μm, which correlates with bubble growth velocity and solution viscosity. Furthermore, as the bubble grows, the central region of the microlayer progressively depletes, leading to direct solid–gas contact and subsequent site deactivation. The exact moment of non-active site formation can be precisely identified by the disappearance of interference fringes. Shao and Tian [287,288] employed digital in-line holographic microscopy to reconstruct the 3D spatial distribution of bubbles within an electrolyzer, thereby enabling 3D Particle Tracking Velocimetry (3D-PTV). Statistical analyses demonstrated that the spatial distribution of bubbles is non-random, exhibiting distinct streamwise streaks, with the size distribution adhering to a log-normal profile.
In conclusion, laser interferometry provides critical nanoscale insights into microlayer thickness, while digital holographic microscopy successfully resolves the 3D spatial distribution and sizing of bubbles, effectively overcoming the overlapping bubble identification issues inherent to 2D techniques. Nevertheless, the application of these techniques in electrolytic gas evolution research remains limited due to several inherent challenges. Primarily, these optical measurement techniques are highly sensitive to environmental vibrations, typically necessitating the use of optical isolation tables. Additionally, digital holography requires intensive post-processing; the holographic reconstruction algorithms carry high computational costs, and image reconstruction quality degrades significantly under high void fraction conditions.

7.2. Two-Phase Flow-Field Measurement Methods

In conventional studies of gas–liquid two-phase pipe flows, contact-based diagnostics have long been the primary means of obtaining local flow information. A representative technique is hot-wire/hot-film anemometry (HWA/HFA). Based on convective heat transfer, this method infers local instantaneous velocity and turbulent fluctuations from the functional relationship between the probe heat-loss rate and the flow speed, and it has been widely used to quantify velocity fields and turbulence structures in vertical gas–liquid flows [289,290]. Serizawa [289] systematically measured liquid-phase turbulence intensity and local void fraction in air–water two-phase flow in a vertical circular pipe using a hot-film probe, establishing a benchmark experimental dataset for turbulence. Wang [290] employed a three-dimensional split hot-film probe to measure Reynolds stresses and turbulence intensity in bubbly flows, revealing the anisotropic nature of bubble-induced turbulence. However, in electrolyzer two-phase-flow studies, the use of such intrusive methods is severely constrained. Industrial electrolyzers typically feature very narrow interelectrode gaps (on the order of millimeters), and inserting a solid probe would inevitably disturb the delicate near-wall bubble layer and may even alter local nucleation and flow states, thereby biasing the measurements. Consequently, contact-based techniques are currently mainly limited to large-scale, fundamental model experiments and are difficult to apply directly to internal flow-field characterization in compact electrolyzers.
To quantitatively resolve velocity fields and turbulence characteristics in gas–liquid flows, non-intrusive optical diagnostics—most notably laser Doppler velocimetry (LDV) and particle image velocimetry (PIV)—have been introduced into water electrolysis research. By tracking the motion of tracer particles suspended in the liquid, these techniques can provide high-resolution velocity information without physically disturbing the flow, and they have become essential for elucidating two-phase-flow mechanisms and validating numerical models.
LDV detects the Doppler frequency shift generated as particles traverse the interference fringes formed by two intersecting laser beams. Owing to its very high temporal resolution, LDV is most commonly used for pointwise velocity measurements [291]. In a comparative study on a small rectangular electrolyzer, Boissonneau [117] systematically assessed the applicability of PIV and LDV and showed that, under strong optical shielding caused by gas evolution, LDV is more robust than PIV and can more accurately capture bubble-induced fluctuations in the local liquid-phase velocity.
In contrast, PIV records particle displacements using double-pulsed laser illumination and provides instantaneous, planar velocity fields. For bubbly flow along vertical electrode surfaces, Hreiz [116] performed tracer-free “direct PIV” by using the bubbles themselves as tracers. To mitigate the interference of large, quasi-static bubbles attached to the electrode surface (VLBs) with cross-correlation, an image pre-processing strategy was proposed in which each instantaneous frame was divided by a time-averaged background image. This procedure removed background features and stationary bubbles, enabling clear extraction of the mean gas-phase velocity vector field, which was then used as benchmark data to validate a Eulerian–Lagrangian CFD model. Kuroda [115] also used PIV to track hydrogen bubbles and, by correlating the Weber number (We) with the Reynolds number (Re), analyzed the dynamic balance among buoyancy, drag, and surface tension during bubble growth and detachment. For flow-field studies in membrane-based electrolyzers, Görtz [123] applied PIV to a partially transparent membrane electrolyzer, resolving time-averaged flow fields at different current densities and revealing how bubble swarms drive a transition of the electrolyte from laminar to pseudo-turbulent behavior. To overcome the lack of depth information inherent to 2D imaging, Wu [292] introduced digital holographic particle-tracking velocimetry (DHPTV), which reconstructs three-dimensional bubble positions and velocity vectors via numerical hologram reconstruction, providing a pathway toward 3D flow-field measurements. Beyond macroscopic flows, optical velocimetry has also been extended toward microscale multiphysics coupling. Babich [293] combined micro-particle-tracking velocimetry (micro-PTV) with Schlieren imaging and directly visualized Marangoni convection around a single bubble induced by Joule heating.
Despite their high accuracy and non-intrusive nature, optical velocimetry techniques still face challenges in water electrolysis environments. First, scattering and occlusion by dense bubble populations limit measurement depth and fidelity. At high current densities, strong optical shielding by dense bubble layers can cause insufficient illumination in regions deep inside the channel (far from the camera), creating blind zones. Second, tracer-particle fidelity and surface contamination effects cannot be neglected. Particularly at the microscale, tracer particles may adsorb at gas–liquid interfaces and alter bubble properties, introducing velocity bias. Finally, the required data post-processing is computationally demanding, which constrains the potential for real-time, in situ monitoring.

7.3. Phase-Distribution Characterization Methods

Accurate characterization of phase distribution inside electrolyzers is essential for validating multiphase-flow models and elucidating how bubbles influence electrochemical performance. However, the complex internal geometry, the optical opacity of porous media, and strong optical shielding by dense bubble swarms at high current densities pose major challenges for in situ measurements. To meet demands across different length scales and accuracy levels, a range of diagnostic approaches has been developed, including optical methods, penetration imaging, and electrical measurement techniques.

7.3.1. Optical Visualization

Optical visualization remains the most intuitive and widely used method for studying two-phase flow in water electrolysis. By retrofitting electrolyzers with transparent windows or building dedicated visual test cells, and combining these setups with high-speed imaging, bubble dynamics can be recorded directly in real time.
This method relies primarily on the refraction and reflection of light at gas–liquid interfaces. A backlighting configuration is commonly adopted, so that bubbles appear as sharp dark silhouettes against a bright background. To overcome limitations of conventional observation, both experimental platforms and image-processing algorithms have been continuously refined. Janssen [129] used transparent-electrode techniques to visualize bubble nucleation and growth on electrode surfaces and quantified bubble-size characteristics within the bubble layer. Bongenaar-Schlenter [130] employed high-speed imaging to estimate the thickness and void-fraction distribution of the bubble accumulation layer on a vertical electrode; combined with segmented-electrode measurements, it was shown that bubble-layer void fraction at different heights can strongly govern local ohmic resistance. With advances in imaging capability, Ikeda [143] developed a microscopic high-speed video system and captured bubble sliding and detachment on a horizontal nickel-wire electrode at frame rates up to 6000 fps. For porous-electrode observations, Rox [145] designed a three-electrode flow cell with dual optical windows and, using a telecentric lens, achieved simultaneous measurements of bubble-size distributions (BSD) and surface coverage on porous nickel electrodes, thereby quantifying the suppression of bubble detachment diameter under forced convection. For dense and overlapping bubble populations, Görtz [141] applied a Mask R-CNN-based deep-learning workflow to the recorded images, enabling reliable edge segmentation and size statistics even for overlapping bubbles.
Optical methods have recently been extended to visualize transport inside microscale pore networks. Using high-speed imaging, Wang [294] compared two-phase transport dynamics in conventional Ti felt and in a thin liquid–gas diffusion layer (LGDL). It was shown that the tortuous pore network of Ti felt promotes bubble trapping and can trigger local drying, whereas the straight-through pores of the thin LGDL enable rapid bubble removal and prompt liquid-water replenishment. These observations highlight the critical role of pore-structure optimization in alleviating mass-transport limitations and improving high-current-density performance. Yuan [295] further investigated transport within the anode catalyst layer (CL) by using a Pt-coated mesh PTL as an in situ oxygen sensor. By monitoring the oxygen-reduction current, assisted by visualization, nanoscale-bubble transport and accumulation inside the catalyst layer were confirmed, providing key evidence for the origin of mass-transfer resistance within the CL.
Despite the rich morphological information it provides, optical visualization faces multiple physical and engineering constraints in practical applications. A primary limitation is the trade-off between optical access and material fidelity. Industrial electrolyzers are typically assembled from stacked opaque metallic plates; experiments therefore often require replacing plates with transparent materials, as in Janssen [129] and Liu [144]. Such substitutions can alter contact resistance, wettability, and thermal boundary conditions, introducing deviations from real operating environments. Moreover, to maintain clear optical paths, conventional transparent cells often cannot sustain clamping pressures comparable to industrial stacks. Insufficient compression can directly change PTL contact resistance and porosity (through compression), thereby affecting bubble nucleation and transport behavior.

7.3.2. Penetration Imaging Methods

Because optical techniques cannot penetrate metallic plates and opaque porous media, penetration imaging—especially high-energy neutron imaging—has become a key tool for resolving internal phase distributions in electrolyzers, particularly within porous transport layers (PTLs).
Neutron–matter interactions are governed primarily by atomic nuclei. Neutrons exhibit strong attenuation in hydrogen-containing materials, while maintaining high penetration through metals such as aluminum and titanium. This contrast makes neutron imaging well suited for discriminating liquid water from gas, and it has been widely used for in situ visualization of water/gas distributions in PTLs, two-phase flow in flow channels, and membrane hydration states. Hoeh [296] quantitatively investigated gas–liquid flow in an anode channel using neutron radiography. By applying the Lambert–Beer law, void-fraction distributions at different current densities were obtained. The results showed that void fraction increased toward the outlet, whereas increasing the anode water flow rate significantly reduced the gas content in the channel and improved bubble-removal efficiency. Seweryn [297] used neutron imaging to show that the water-layer thickness within a porous sintered-titanium anode remained nearly constant over a wide current-density range (0.1–2.5 A·cm−2), indicating that water starvation was unlikely even at high current densities. Selamet [155,298] performed synchronized neutron radiography and optical imaging (Figure 21); by spatially correlating neutron-derived water-thickness maps with optically observed bubble morphologies, bubble occupancy in neutron images was distinguished from the Ti-mesh structure. This combined analysis directly demonstrated that bubble accumulation in channels can locally deplete liquid-water content and thereby promote gas blockage.
Figure 21. (a) Schematic of the experimental setup for the simultaneous visualization of water electrolysis using high-speed imaging and neutron imaging [155]. Copyright 2011, IOP Publishing. (b) False-color transient neutron images of the PEM electrolyzer operated at 40 °C and 0.1 A·cm−2 [155]. Copyright 2011, IOP Publishing.
Neutron imaging has also been used to interrogate mass-transport limitations inside PTLs at high current densities. Using high-precision in situ neutron radiography together with ex situ X-ray tomography–derived structural data, Maier [243] quantified water saturation within the PTL. The results showed that PTL water content decreased nonlinearly with increasing current density. Interestingly, regions with higher local flow velocities induced by the flow-field design (e.g., near the outlet) exhibited better PTL hydration, highlighting the strong influence of flow-field geometry on in-plane mass-transport distribution. Panchenko [299] applied neutron radiography to compare PTLs with different structures (sintered Ti powder vs. Ti fiber felt) under low-stoichiometry water supply. At higher current density (0.6 A·cm−2), the generated gas could not be fully removed, forming a blocking layer that impeded water delivery to the membrane [299]. From a macroscopic performance-correlation perspective, Minnaar [166] coupled neutron-derived water-distribution maps with current-density distributions measured using a segmented circuit board, confirming a strong spatial correlation between gas-holdup regions caused by suboptimal flow-field designs and locally depressed current-density zones. Another penetrating imaging method is operando synchrotron X-ray computed tomography (X-ray CT), which can resolve internal phase distributions in PEM electrolyzers. As shown in Figure 22, it enables visualization of MEA structures and PTL bubble distributions under operando conditions [154].
Figure 22. (a) Schematic of the operando X-ray CT experimental setup for a PEM electrolyzer [154]. (b) Spatial distribution of bubbles in the PTL at operating temperatures of 40 °C, 60 °C, and 80 °C at a current density of 4 A·cm−2 [154].
Despite its distinctive advantages for visualizing liquid water, neutron imaging still faces substantial barriers to widespread use. First, it requires specialized facilities, scarce neutron sources, and stringent radiation-safety protocols, which limits routine adoption. Second, physical limits in spatial resolution constrain microscale characterization: conventional neutron imaging typically provides resolutions on the order of tens of micrometers, making it difficult to resolve submicrometer pore structures inside PTLs or small bubbles near catalyst-layer interfaces. Third, because neutron flux is limited, relatively long exposure times are often required to achieve sufficient signal-to-noise ratios, which restricts temporal resolution and makes it challenging to capture fast transient bubble dynamics (e.g., coalescence and collapse). Neutron imaging is therefore more suitable for tracking quasi-steady evolution of two-phase distributions.

7.3.3. Electrical Measurement Methods

To obtain phase-distribution information more directly across channel cross-sections, some studies have employed intrusive wire-resistance array measurements. The underlying principle is that empirical relations—such as the Maxwell or Bruggeman formulas—provide a quantitative link between the effective electrical conductivity of a gas–liquid mixture and the void fraction. By measuring local resistance variations at specified locations in the channel, the local gas volume fraction can be inferred. Riegel [132] placed an array of 0.1 mm-diameter Pt wires inside the flow channel as horizontal sensing electrodes. By measuring voltage drops between wires at different elevations, void-fraction distributions were quantified under different current densities. Similarly, to validate a two-phase-flow numerical model, Aldas [126] installed a wire-resistance array in the cell and obtained void-fraction profiles along the channel height by monitoring resistivity fluctuations at multiple positions on the outlet cross-section in real time. The results showed that increasing current density markedly intensified near-electrode bubble accumulation, which in turn caused a substantial rise in local ohmic resistance.
Although these contact-based electrical methods provide valuable experimental data for understanding two-phase structures inside electrolyzers, their limitations are also evident. First, intrusive disturbance is unavoidable: wire arrays placed in narrow channels act as flow obstacles, which can alter local velocity fields and turbulence structures, and may also serve as additional nucleation sites or coalescence centers. As a result, the original flow state can be biased. Second, accuracy and spatial resolution are constrained. Owing to practical limits on probe number and placement density, such measurements typically provide cross-section-averaged void fractions or values at a limited set of discrete points, rather than high-resolution field data. Third, the inversion procedure relies on conductivity–void-fraction relations that are often derived under assumptions of uniformly dispersed bubbles; when bubble morphology becomes complex or the flow regime transitions (e.g., from bubbly to slug flow), the associated errors can increase substantially.
To overcome the limitation that many traditional diagnostics only yield averaged performance metrics, segmented-cell techniques have been introduced to map current-density distributions with high spatial resolution. In this method, the current collector is partitioned into electrically isolated segments using a printed circuit board (PCB) or an array of shunt resistors, enabling local current measurements. Dedigama [138] designed a PEM electrolyzer with optical windows and a PCB-based segmented current collector, allowing simultaneous flow visualization and current-density mapping. Their results showed that when the regime transitioned from bubbly flow to slug flow, the local current density did not decrease as might be expected from bubble masking. Instead, it increased because slug bubbles rapidly swept smaller bubbles from the electrode surface, revising the conventional view of bubble–current coupling. Minnaar [166] combined segmented-current measurements with neutron radiography on a 25 cm2 flow field and established a direct correspondence between water distribution and current density. It was observed that gas-holdup regions caused by suboptimal flow-field designs spatially coincided with low-current-density regions, indicating that local drying and gas coverage are major drivers of reduced active-area utilization. In addition, Parra-Restrepo [300] used a segmented cell to examine how PTL pore characteristics affect mass transfer; by analyzing streamwise current-density decay profiles, transport limitations associated with different PTL structures during two-phase transport were revealed.
Although segmented-cell techniques provide valuable spatially resolved information, several challenges remain in practice. A major issue is interference from lateral currents. Because the proton-exchange membrane and porous transport layers are laterally continuous, current inevitably spreads between adjacent segments. This lateral conduction causes the measured current-density field to appear smoother than the true distribution, thereby blurring sharp boundaries associated with local defects or bubble accumulation. In addition, improving spatial resolution requires increasing the number of segments, which substantially raises wiring complexity and the cost of the data-acquisition system. Therefore, achieving an appropriate balance among spatial resolution, system complexity, and measurement fidelity remains a key challenge for further development of segmented-cell diagnostics.

7.3.4. Acoustic Measurement Methods

Acoustic techniques exploit sound propagation and attenuation in two-phase media, providing a non-intrusive, non-radiative, and relatively low-cost option for monitoring internal states in electrolyzers. Depending on how the acoustic signal is generated, these methods can be broadly categorized into passive acoustic emission that monitors bubble-generated noise and active ultrasonic techniques that employ an external acoustic source.
Acoustic emission (AE) is a passive monitoring method that records transient elastic-wave signals generated during electrolyzer operation, enabling indirect characterization of internal two-phase conditions. In a transparent PEM electrolyzer, Maier [301] mounted piezoelectric AE sensors outside the flow channels to acquire in situ acoustic signals and systematically analyzed how AE hit characteristics varied with operating conditions. The results showed that the AE hit rate changed markedly with increasing current density, and the observed trends correlated well with gas-production levels and flow regime evolution. By comparison with visual observations, it was found that bubbly-flow conditions produced frequent but low-amplitude hits. During the transition toward slug flow, the hit rate reached a maximum and then decreased as large-scale gas structures began to dominate the flow. These findings suggest that statistical features of AE hits (e.g., hit rate and frequency content) can be used for non-intrusive identification of two-phase flow regime transitions in PEM electrolyzers.
Acoustic time-of-flight (AToF) imaging uses the reflection of ultrasonic pulses at interfaces between media to probe internal structures and fluid distributions. Maier [302] implemented an in situ scan of a PEM electrolyzer using a phased array consisting of 64 piezoelectric transducers operated in pulse–echo mode. Using maps of acoustic reflection intensity, the rib–channel architecture of the flow-field plate and macroscopic features of the porous transport layer (PTL) were successfully visualized. For two-phase characterization, the reflection intensity in the channel region decreased markedly with increasing current density, which was attributed to resonant scattering by bubbles and followed an approximately logarithmic decay. For the PTL region, the measured reflection-intensity trends were compared with previously reported neutron-radiography data obtained on the same material. The magnitude of variation with current density was highly consistent between the two methods (a ~13% decrease in acoustic intensity corresponding to a ~12% reduction in water thickness), supporting the feasibility of using AToF for non-intrusive monitoring of PTL hydration and gas–liquid distribution differences.
Despite these advantages, applying acoustic methods in high-void-fraction two-phase environments remains challenging. First, strong scattering and attenuation by bubbles constitute a key bottleneck. When gas saturation in pores becomes high, ultrasound penetration into deeper regions is severely hindered, and echo signals can become weak or even vanish, limiting detection depth at very high current densities [302]. Second, signal interpretation is nontrivial: acoustic emission measurements often contain background contributions from pumping noise and structural vibrations, and extracting informative features typically requires advanced filtering and spectral analyses. Third, compared with penetration imaging, acoustic imaging generally offers lower spatial resolution and is currently better suited for macroscopic regime identification and mesoscale distribution monitoring than for resolving micrometer-scale pore structures.

7.4. Integration of Two-Phase Flow and Electrochemical Characterization Methods

The development and evolution of two-phase flow within the electrolyzer profoundly impact the system’s energy consumption and overall electrolytic performance. Employing accurate and rational electrochemical characterization methods is crucial for further elucidating the extent and underlying mechanisms of two-phase flow effects. Consequently, integrating two-phase flow characteristics with electrochemical performance is imperative in water electrolysis research. As an illustrative example, Figure 23 shows how two-phase-flow observations can be directly coupled with electrochemical measurements: high-speed imaging can be integrated with a three-electrode configuration to correlate bubble dynamics with electrochemical response, while bubble-layer morphology and thickness can be further linked to changes in ohmic resistance under controlled conditions.
Figure 23. (a) Integrated water electrolysis measurement system with a three-electrode configuration and high-speed imaging [140]. Copyright 2025, American Chemical Society. (b) Bubble layers observed at the electrode surface under different solution environments, electrode orientations, and gravitational conditions [171]. Copyright 2006, IOP Publishing. (c) Relationship between the ohmic resistance and the thickness of the gas bubble layer in a 2 wt.% KOH solution under the μ−G condition at 0.2 A·cm−2, with an added schematic illustration of the measurement of bubble-layer resistance [171]. Copyright 2006, IOP Publishing.
Based on diverse measurement principles, multiple electrochemical characterization methods have been applied to two-phase flow studies in water electrolysis. Cyclic Voltammetry (CV) and Linear Sweep Voltammetry (LSV) are the most widely utilized electrochemical techniques in this field. By analyzing the shape, slope variations, and unsteady-state features of the voltammetric curves, these methods can elucidate the dominant control mechanisms of the electrolysis process and investigate the impacts of bubble growth and detachment on electrolytic performance. As a frequency-domain analytical technique, Electrochemical Impedance Spectroscopy (EIS) applies perturbation signals across a broad frequency spectrum. Based on the distinct time constants of various physicochemical processes, EIS can differentiate among electrochemical reaction kinetics, ohmic losses, and diffusion processes. Typically, Nyquist plots are combined with equivalent circuit models to investigate key system parameters, including solution resistance (Rs), double-layer capacitance (Cdl), and charge transfer resistance (Rct). Furthermore, Electrochemical Noise Analysis (ENA) serves as an in situ, non-destructive monitoring technique capable of capturing fluctuations in electrode potential and current within the electrochemical system. Utilizing Power Spectral Density (PSD) analysis, ENA is effectively employed to study the gas evolution process and its subsequent influence on electrical signal [303,304].
Both surface gas evolution and internal two-phase flow significantly impact water electrolysis performance. By utilizing various electrochemical testing methods, researchers have systematically investigated the coupling of gas evolution phenomena with corresponding electrochemical signals across diverse bubble systems.
Regarding the integration of single-bubble evolution and electrochemical signals, the inherent periodicity of single-bubble detachment induces fluctuations in both electrode and electrolyte properties, subsequently generating corresponding oscillations in the electrochemical signals. Therefore, researchers conventionally synchronize real-time captures of bubble evolution with these fluctuating electrical signals. Utilizing cyclic voltammetry and in situ microscopic imaging, German [305] established a direct correlation between single-bubble generation on nano-Pt electrodes and sudden current drops. Employing a synchronized strategy of potentiostatic experiments and optical microscopy, Yang [66] confirmed the intrinsic consistency between current fluctuation cycles and bubble detachment cycles, while also analyzing how dynamic bubble dimensions influence current density. Similarly investigating the HER system on microelectrodes, Park [91] correlated chronoamperometric curves from potentiostatic experiments with high-speed microscopic images, thereby revealing non-periodic fluctuation characteristics embedded within the electrochemical signals. Furthermore, Bashkatov [82] simultaneously captured oscillatory bubble growth modes and current density responses across various cathodic potentials. Using optical imagery, this study elucidated the coupling relationship between current fluctuations during a single bubble’s growth cycle and the varying thickness of the microbubble layer beneath a larger macro-bubble. Beyond time-domain analyses, Dastafkan [306] introduced EIS as a frequency-domain approach. By monitoring the dynamic response of solution resistance in the high-frequency region, a correlational analysis was conducted between the amplitude of resistance fluctuations and the size and frequency of detached bubbles. Currently, pertinent research remains heavily concentrated on the impacts of single-bubble growth and detachment. Investigations coupling multi-bubble evolution behaviors (e.g., growth, detachment, and coalescence) with electrochemical signals are notably sparse. This critical gap restricts a more profound understanding of the coupling mechanisms between macroscopic gas evolution and global electrochemical responses.
By characterizing two-phase flow in electrolyzers and jointly analyzing electrochemical signals, quantitative links can be established between gas-phase distribution and the evolution of performance losses, enabling more effective mechanistic interpretation of their coupling. Using ohmic-impedance-based inversion, de Jonge [152] estimated the overall void fraction in an electrolyzer and found a nonlinear dependence of the overall void fraction on the total current. Subsequent efforts further emphasized spatial non-uniformity in phase distribution. To examine streamwise gas accumulation, Hine [157] installed ten electrodes at different streamwise heights and showed that, under the same applied potential, the current density near the top outlet could differ from that near the bottom inlet by a factor of two, indicating that along-channel gas buildup can strongly redistribute local load. Along the electrode-normal direction, Riegel [132] used a wire-resistance array aligned with the electrode to quantify transverse void-fraction profiles, and reported that electrolyzer performance deteriorated markedly when improper gas–liquid flow-rate ratios induced recirculation.
With advances in non-intrusive diagnostics, gas-phase structures can now be obtained in situ and compared synchronously with electrochemical signals. Using a transparent cell with high-speed imaging, Kuroda [115] correlated phase-distribution images with real-time current-density responses under potentiostatic control and found that the appearance of large slug-like bubbles coincided with a pronounced drop in the measured local current density. Ito [161] visualized flow regime transitions in a transparent PEM electrolyzer and linked them to voltage-loss variations at high current density, enabling discussion of regime-dependent water supply and mass-transfer conditions. Majasan [139] used a transparent PEM electrolyzer to record flow regime evolution and voltage responses in the same setup, thereby analyzing how current density, water feed rate, and temperature affect channel gas distribution and its electrochemical implications. Su [226] similarly quantified flow regimes and gas-coverage area in a PEM electrolyzer and related these metrics to current density and cell voltage. By combining optical visualization with electrochemical impedance spectroscopy (EIS), Dedigama [307] reported that mass transfer tended to be enhanced during the transition from bubbly to slug flow, suggesting that regime change can simultaneously modify gas renewal and transport conditions. In the near-electrode region, Kiuchi [171] measured bubble-layer thickness optically while simultaneously recording solution ohmic impedance, providing an experimental route to link bubble-layer structure with ohmic losses. Beyond optical approaches, penetration and other non-intrusive diagnostics have also been used to couple internal two-phase distributions in opaque porous media with electrochemical behavior. Selamet [298] combined neutron imaging with optical imaging to obtain in situ gas–liquid distributions in opaque regions such as PTLs and correlate them with electrochemical performance. Panchenko [299] applied in situ neutron-based methods to probe two-phase characteristics in different PTLs and compared the results with changes in polarization curves.
Overall, although integrated characterization methods that combine two-phase diagnostics with electrochemical measurements are rapidly expanding, a consistent understanding is still lacking regarding how phase-distribution evolution and non-uniformity contribute—under different operating conditions—to activation, ohmic, and mass-transfer losses. Comparable quantitative analyses and validations, based on synchronized acquisition of phase-distribution information and electrochemical signals, remain needed.

8. Conclusions

This review has focused on gas evolution at electrode surfaces during water electrolysis and the associated gas–liquid two-phase flow within electrolyzers. Starting from interfacial processes, the physical basis and primary controlling factors of key stages—nucleation, growth, detachment, and coalescence—have been summarized. It has been emphasized that continuous gas generation at the electrode surface, acting as a distributed source term, not only reshapes near-electrode coverage and mass-transport conditions but also constitutes the foundation for the formation and evolution of two-phase flow in channels. The coupled relationship between gas migration and liquid-phase motion has then been synthesized, together with the pronounced cross-sectional non-uniformity of phase distribution and its streamwise development. The applicability and limitations of major numerical approaches for two-phase flow in electrolyzers—including the mixture model, Eulerian–Eulerian, Eulerian–Lagrangian, VOF, and IBM models—have also been outlined. With respect to performance, the pathways by which two-phase structures influence electrolysis behavior have been consolidated in terms of activation, ohmic, and mass-transport losses. Progress in two-phase-flow management has been reviewed across flow-field organization and regulation, surface modification and structural design, and external-field control. In addition, major characterization techniques for two-phase flow in electrolyzers have been summarized. Overall, existing studies have established a relatively comprehensive framework for understanding bubbles and two-phase processes in water electrolysis.
Although substantial progress has been made in electrolyzer two-phase-flow research, major challenges remain in meeting future demands for high current densities and operation under wide power fluctuations. In view of current limitations and emerging technical trends, future work could be directed toward the following priority:
Multiscale characterization and kinetic analysis of two-phase flow. Gas evolution and gas–liquid flow in water electrolysis exhibit pronounced multiscale behavior, yet the governing kinetics have not been systematically resolved. (i) At the molecular scale, bubble nucleation originates from the accumulation of supersaturated dissolved gas and phase transition near the interface. While classical nucleation theory and cavitation concepts can explain parts of the observed behavior, direct evidence remains limited under realistic electrochemical interfaces, where local concentration, electric-field distributions, and interfacial structures are tightly coupled. The transient evolution and spatial distribution of interfacial supersaturation remain difficult to measure in situ, and corresponding nucleation rates and site-activation statistics have yet to be quantified. Higher-resolution interfacial diagnostics, together with molecular-scale kinetic analyses, are therefore needed to refine nucleation models. (ii) At the bubble scale, although single-bubble growth and detachment have been extensively studied, multi-bubble coexistence and interactions become dominant at high current densities. Coalescence, interfacial deformation, and unsteady force redistribution can substantially reshape local flow fields and phase distributions, but systematic theoretical descriptions of these coupled evolutions are still lacking. Multi-bubble dynamic models that couple interfacial deformation with electrochemical reactions should be developed within a two-phase hydrodynamics framework. (iii) At the macroscopic scale, continuous gas evolution at electrodes forms a wall-distributed source term that governs the internal flow field and phase-distribution structures. Existing studies have provided streamwise-velocity and cross-sectional void-fraction datasets, yet under narrow-gap and high-void-fraction conditions, near-wall and porous-layer-resolved flow structures and phase distributions remain insufficiently characterized. In addition, the influence of coupled physicochemical fields on the overall two-phase structure is not yet well understood. Future progress will likely require the development of multiphysics-coupled two-phase hydrodynamic models grounded in systematic experimental measurements, enabling cross-scale linkage and validation.
Impacts of two-phase flow on electrochemical performance and material stability. The influence of two-phase flow on electrolyzer performance and material stability has received broad attention, yet the underlying pathways and dominant mechanisms have not been systematically consolidated. (i) From the performance perspective, two-phase flow can act simultaneously on activation, ohmic, and mass-transport processes. Bubble coverage on electrode surfaces is widely expected to reduce the effective reactive area; however, systematic evidence remains limited on how activation losses vary with operating conditions and how they correlate with bubble dynamics. Spatially non-uniform phase distributions can alter the effective conductive cross-section and induce current redistribution, thereby modifying ohmic losses and local interfacial overpotentials, but the coupled relationship among phase distribution, flow structure, and current redistribution has not been resolved in a unified manner. In addition, flow-induced changes in boundary-layer structure affect reactant supply and product removal; under high void fractions, the competition between bubble-induced local enhancement and suppression caused by gas blockage remains insufficiently quantified. (ii) For material stability, long-term mechanistic evidence is likewise incomplete. On the one hand, phase non-uniformity can drive current redistribution, forcing certain regions to sustain higher electrochemical loads, yet a quantitative linkage between the degree of current localization and degradation rate has not been established. On the other hand, pressure fluctuations and interfacial impacts associated with bubble growth and detachment may impose cyclic stresses on electrodes and separators, but whether such dynamic perturbations are sufficient to promote microcrack propagation or pore-structure damage remains largely speculative. Accordingly, combined electrochemical diagnostics and materials characterization are needed to disentangle the respective roles of flow, phase distribution, and current fields, to identify the dominant voltage-loss mechanisms under different operating regimes, and to establish quantitative correlations between bubble behavior and material stability, thereby providing a clearer basis for performance assessment and lifetime improvement.
Combined strategies of structural design and active regulation. Electrode or flow-field structural design and external active regulation can serve as parallel and complementary routes for gas-phase management. Deterministic porous electrodes and optimized flow-field architectures impose geometric constraints that shape gas–liquid distributions across relevant length scales, whereas magnetic fields, ultrasound, or periodic perturbations can dynamically modulate bubble behavior during operation. Synergistic integration of these approaches may broaden the operating envelope over which two-phase conditions can be effectively managed; however, stability and engineering feasibility still need to be evaluated under conditions that closely resemble practical operation.

Author Contributions

Conceptualization, J.Z., J.L. and Q.S.; investigation, J.Z., J.L. and K.W.; resources, Y.D. and Q.S.; data curation, J.Z., J.L. and Y.A.; writing—original draft preparation, J.Z. and J.L.; writing—review and editing, J.Z., J.L. and Q.S.; supervision, Q.S.; project administration, Q.S.; funding acquisition, Y.D. and Q.S. All authors have read and agreed to the published version of the manuscript.

Funding

This research was supported by Shanxi Province Science and Technology Major Projects (202401060301011) and the Fundamental Research Funds for the Central Universities of China (2022ZFJH04).

Data Availability Statement

No new data were created or analyzed in this study.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. van der Zwaan, B.; Fattahi, A.; Dalla Longa, F.; Dekker, M.; van Vuuren, D.; Pietzcker, R.; Rodrigues, R.; Schreyer, F.; Huppmann, D.; Emmerling, J.; et al. Electricity- and Hydrogen-Driven Energy System Sector-Coupling in Net-Zero CO2 Emission Pathways. Nat. Commun. 2025, 16, 1368. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  2. van der Spek, M.; Banet, C.; Bauer, C.; Gabrielli, P.; Goldthorpe, W.; Mazzotti, M.; Munkejord, S.T.; Røkke, N.A.; Shah, N.; Sunny, N.; et al. Perspective on the Hydrogen Economy as a Pathway to Reach Net-Zero CO2 Emissions in Europe. Energy Environ. Sci. 2022, 15, 1034–1077. [Google Scholar] [CrossRef] [Scilit]
  3. Odenweller, A.; Ueckerdt, F. The Green Hydrogen Ambition and Implementation Gap. Nat. Energy 2025, 10, 111–123. [Google Scholar] [CrossRef] [Scilit]
  4. Kwon, J.; Choi, S.; Park, C.; Han, H.; Song, T. Critical Challenges and Opportunities for the Commercialization of Alkaline Electrolysis: High Current Density, Stability, and Safety. Mater. Chem. Front. 2024, 8, 41–81. [Google Scholar] [CrossRef] [Scilit]
  5. Ge, X.; Xiao, Y.; Zhao, G.; Luo, X.; Liu, J.; Chen, J.; He, P.; Huang, M.; Qiao, J. Early-Stage Performance Degradation Mechanisms of Proton-Exchange Membrane Water Electrolysis under High Operating Current Densities. Fuel 2025, 386, 134344. [Google Scholar] [CrossRef] [Scilit]
  6. Kou, T.; Wang, S.; Shi, R.; Zhang, T.; Chiovoloni, S.; Lu, J.Q.; Chen, W.; Worsley, M.A.; Wood, B.C.; Baker, S.E.; et al. Periodic Porous 3D Electrodes Mitigate Gas Bubble Traffic during Alkaline Water Electrolysis at High Current Densities. Adv. Energy Mater. 2020, 10, 2002955. [Google Scholar] [CrossRef] [Scilit]
  7. Taqieddin, A.; Nazari, R.; Rajic, L.; Alshawabkeh, A. Review—Physicochemical Hydrodynamics of Gas Bubbles in Two Phase Electrochemical Systems. J. Electrochem. Soc. 2017, 164, E448–E459. [Google Scholar] [CrossRef] [Scilit]
  8. Kempler, P.A.; Coridan, R.H.; Luo, L. Gas Evolution in Water Electrolysis. Chem. Rev. 2024, 124, 10964–11007. [Google Scholar] [CrossRef] [Scilit]
  9. Zhao, X.; Ren, H.; Luo, L. Gas Bubbles in Electrochemical Gas Evolution Reactions. Langmuir 2019, 35, 5392–5408. [Google Scholar] [CrossRef] [Scilit]
  10. Struyven, F.; Sellier, M.; Mandin, P. Review: Interactions between Electrogenerated Bubbles and Microfluidic Phenomena. Int. J. Hydrogen Energy 2023, 48, 32607–32630. [Google Scholar] [CrossRef] [Scilit]
  11. Deng, L.; Jin, L.; Yang, L.; Feng, C.; Tao, A.; Jia, X.; Geng, Z.; Zhang, C.; Cui, X.; Shi, J. Bubble Evolution Dynamics in Alkaline Water Electrolysis. Escience 2025, 5, 100353. [Google Scholar] [CrossRef] [Scilit]
  12. Hreiz, R.; Abdelouahed, L.; Fünfschilling, D.; Lapicque, F. Electrogenerated Bubbles Induced Convection in Narrow Vertical Cells: A Review. Chem. Eng. Res. Des. 2015, 100, 268–281. [Google Scholar] [CrossRef] [Scilit]
  13. Iwata, R.; Zhang, L.; Wilke, K.L.; Gong, S.; He, M.; Gallant, B.M.; Wang, E.N. Bubble Growth and Departure Modes on Wettable/Non-Wettable Porous Foams in Alkaline Water Splitting. Joule 2021, 5, 887–900. [Google Scholar] [CrossRef] [Scilit]
  14. da Silva, J.; Nobrega, E.; Staciaki, F.; Almeida, F.R.; Wosiak, G.; Gutierrez, A.; Bruno, O.; Lopes, M.C.; Pereira, E. Beyond Bubbles: Unraveling the Interfacial pH Effects on Bubble Size Distribution. Chem. Eng. J. 2024, 494, 152943. [Google Scholar] [CrossRef] [Scilit]
  15. Yi, Q.; Ai, T.; Han, Y.; Zhu, Z.; Fang, W.; Zhou, H. Research on the Mechanism of Bubble Sizes Evolution in Industrial-Scale Bipolar Plates with Serpentine Flow Field. Chem. Eng. J. 2025, 509, 161292. [Google Scholar] [CrossRef] [Scilit]
  16. Pyun, I.; Na, Y. Visualization Experiment to Understand Two-Phase Flow Characteristics inside the Anode Flow Path of Proton Exchange Membrane Water Electrolysis with 100 cm2 Circular Active Area. Int. J. Hydrogen Energy 2025, 106, 537–545. [Google Scholar] [CrossRef] [Scilit]
  17. Angulo, A.; Van Der Linde, P.; Gardeniers, H.; Modestino, M.; Fernández Rivas, D. Influence of Bubbles on the Energy Conversion Efficiency of Electrochemical Reactors. Joule 2020, 4, 555–579. [Google Scholar] [CrossRef] [Scilit]
  18. Xu, N.; Qiu, B.; Rui, Z.; Ji, T.; Liu, Z.; Chu, H. Effect of Heat and Bubble Mass Transfer on the Efficiency of Alkaline Electrolysis Hydrogen Production. Nano Res. 2024, 17, 9345–9370. [Google Scholar] [CrossRef] [Scilit]
  19. Wu, L.; Wang, Q.; Yuan, S.; Mei, X.; Wang, Q.; Zou, X.; Zhang, K.; Huo, X.; Shi, X.; Pan, Z.; et al. Unrevealing the Interaction between Electrode Degradation and Bubble Behaviors in an Anion Exchange Membrane Water Electrolyzer. Adv. Sci. 2025, 12, 2412962. [Google Scholar] [CrossRef] [Scilit]
  20. Tan, A.; Song, J.; Qiu, X.; Liu, Z.; Xia, L.; Ju, C.; Zhao, F.; Li, G.; Shi, X.; Li, T.; et al. Catastrophic Localized Deflagration Formation Mechanisms and Safety Precautions in Proton Exchange Membrane Water Electrolyzer. Nat. Commun. 2025, 16, 9115. [Google Scholar] [CrossRef] [Scilit]
  21. Padgett, E.; Yu, H.; Blair, S.J.; Cullen, D.A.; Ahluwalia, R.K.; Myers, D.J.; Pivovar, B.; Alia, S.M. Quantifying Sources of Voltage Decay in Long-Term Durability Testing for PEM Water Electrolysis. J. Electrochem. Soc. 2025, 172, 54508. [Google Scholar] [CrossRef] [Scilit]
  22. Kimmel, B.; Morawietz, T.; Gazdzicki, P.; Gago, A.S.; Friedrich, K.A. Degradation Mechanisms of a Proton Exchange Membrane Water Electrolyzer Stack Operating at High Current Densities. Electrochim. Acta 2025, 542, 147395. [Google Scholar] [CrossRef] [Scilit]
  23. Finger, S.; Fritsch, B.; Wu, M.; Lahn, L.; Hoffmeister, D.; Will, J.; Kasian, O.; Spiecker, E.; Thiele, S.; Freiberg, A.T.S.; et al. Degradation Phenomena in PEMWE Revealed by Correlative Electrochemical and Nanostructure Analysis. Energy Environ. Sci. 2025, 18, 9877–9894. [Google Scholar] [CrossRef] [Scilit]
  24. Yin, W.; Yuan, L.; Huang, H.; Cai, Y.; Pan, J.; Sun, N.; Zhang, Q.; Shu, Q.; Gu, C.; Zhuang, Z.; et al. Strategies to Accelerate Bubble Detachment for Efficient Hydrogen Evolution. Chin. Chem. Lett. 2024, 35, 108351. [Google Scholar] [CrossRef] [Scilit]
  25. Yang, L.; Gao, L.; Shan, G.; Huo, X.; Zhang, M.; Wang, Y.; Liu, X.; Kong, A.; Wu, J.; Zhang, J. Recent Progress of Enhanced Bubble Separation in Alkaline Water Electrolyzer. Chem. Synth. 2023, 3, 41. [Google Scholar] [CrossRef] [Scilit]
  26. Yuan, S.; Zhao, C.; Cai, X.; An, L.; Shen, S.; Yan, X.; Zhang, J. Bubble Evolution and Transport in PEM Water Electrolysis: Mechanism, Impact, and Management. Prog. Energy Combust. Sci. 2023, 96, 101075. [Google Scholar] [CrossRef] [Scilit]
  27. Swiegers, G.F.; Terrett, R.N.L.; Tsekouras, G.; Tsuzuki, T.; Pace, R.J.; Stranger, R. The Prospects of Developing a Highly Energy-Efficient Water Electrolyser by Eliminating or Mitigating Bubble Effects. Sustain. Energy Fuels 2021, 5, 1280–1310. [Google Scholar] [CrossRef] [Scilit]
  28. Cheng, X.; Du, Z.; Ding, Y.; Li, F.; Hua, Z.; Liu, H. Bubble Management for Electrolytic Water Splitting by Surface Engineering: A Review. Langmuir 2023, 39, 16994–17008. [Google Scholar] [CrossRef] [Scilit]
  29. Lv, H.; Chen, J.; Zhou, W.; Shen, X.; Zhang, C. Mechanism Analyses and Optimization Strategies for Performance Improvement in Low-Temperature Water Electrolysis Systems via the Perspective of Mass Transfer: A Review. Renew. Sustain. Energy Rev. 2023, 183, 113394. [Google Scholar] [CrossRef] [Scilit]
  30. Sun, H.; Xu, X.; Kim, H.; Jung, W.; Zhou, W.; Shao, Z. Electrochemical Water Splitting: Bridging the Gaps between Fundamental Research and Industrial Applications. Energy Environ. Mater. 2023, 6, e12441. [Google Scholar] [CrossRef] [Scilit]
  31. Sunny, A.; Darsan, A.S.; Rajalekshmi, S.; Ashok, V.; Rithanya, K.; Kanishga, L.; Arasan, S.K.; Pandikumar, A. Device Engineering and Mechanisms for Electrocatalytic Water Splitting: Conventional to Decoupled Electrolyzer. Appl. Energy 2026, 404, 127110. [Google Scholar] [CrossRef] [Scilit]
  32. Yang, N.; Li, H.; Lin, X.; Georgiadou, S.; Hong, L.; Wang, Z.; He, F.; Qi, Z.; Lin, W.-F. Catalytic Electrode Comprising a Gas Diffusion Layer and Bubble-Involved Mass Transfer in Anion Exchange Membrane Water Electrolysis: A Critical Review and Perspectives. J. Energy Chem. 2025, 105, 669–701. [Google Scholar] [CrossRef] [Scilit]
  33. He, Y.; Cui, Y.; Zhao, Z.; Chen, Y.; Shang, W.; Tan, P. Strategies for Bubble Removal in Electrochemical Systems. Energy Rev. 2023, 2, 100015. [Google Scholar] [CrossRef] [Scilit]
  34. Qiu, J.; Yao, J.; Feng, Z.; Huang, B.; Luo, Z.; Wang, L. Enhancing Water Electrolysis Performance by Bubble Behavior Management. Small Methods 2025, 9, 2402105. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  35. Vogt, H. Interfacial Supersaturation at Gas Evolving Electrodes. J. Appl. Electrochem. 1993, 23, 1323–1325. [Google Scholar] [CrossRef] [Scilit]
  36. Maciel, P.; Nierhaus, T.; Damme, S.V.; Parys, H.V.; Deconinck, J.; Hubin, A. New Model for Gas Evolving Electrodes Based on Supersaturation. Electrochem. Commun. 2009, 11, 875–877. [Google Scholar] [CrossRef] [Scilit]
  37. Gubbins, K.E.; Walker, R.D. The Solubility and Diffusivity of Oxygen in Electrolytic Solutions. J. Electrochem. Soc. 1965, 112, 469. [Google Scholar] [CrossRef] [Scilit]
  38. Christmas, K.M.; Bassingthwaighte, J.B. Equations for O2 and CO2 Solubilities in Saline and Plasma: Combining Temperature and Density Dependences. J. Appl. Physiol. 2017, 122, 1313–1320. [Google Scholar] [CrossRef] [Scilit]
  39. Schalenbach, M.; Lueke, W.; Stolten, D. Hydrogen Diffusivity and Electrolyte Permeability of the Zirfon PERL Separator for Alkaline Water Electrolysis. J. Electrochem. Soc. 2016, 163, F1480. [Google Scholar] [CrossRef] [Scilit]
  40. Nir, S.; Adams, S.; Rein, R. Polarizability Calculations on Water, Hydrogen, Oxygen, and Carbon Dioxide. J. Chem. Phys. 1973, 59, 3341–3355. [Google Scholar] [CrossRef] [Scilit]
  41. Westerheide, D.E.; Westwater, J.W. Isothermal Growth of Hydrogen Bubbles during Electrolysis. AIChE J. 1961, 7, 357–362. [Google Scholar] [CrossRef] [Scilit]
  42. Shibata, S. The Concentration of Molecular Hydrogen on the Platinum Cathode. Bull. Chem. Soc. Jpn. 1963, 36, 53–57. [Google Scholar] [CrossRef] [Scilit]
  43. Sakuma, G.; Fukunaka, Y.; Matsushima, H. Nucleation and Growth of Electrolytic Gas Bubbles under Microgravity. Int. J. Hydrogen Energy 2014, 39, 7638–7645. [Google Scholar] [CrossRef] [Scilit]
  44. Shibata, S. Supersaturation of Oxygen in Acidic Solution in the Vicinity of an Oxygen-Evolving Platinum Anode. Electrochim. Acta 1978, 23, 619–623. [Google Scholar] [CrossRef] [Scilit]
  45. Liu, Y.; Lu, X.; Peng, Y.; Chen, Q. Electrochemical Visualization of Gas Bubbles on Superaerophobic Electrodes Using Scanning Electrochemical Cell Microscopy. Anal. Chem. 2021, 93, 12337–12345. [Google Scholar] [CrossRef] [Scilit]
  46. Tanaka, Y.; Kikuchi, K. Dissolution of Hydrogen Produced by Water Electrolysis: Effects of Electrode Roughness Factor and Current Density. Results Chem. 2023, 5, 100984. [Google Scholar] [CrossRef] [Scilit]
  47. Wang, Z.; Yu, Y.; Qin, M.; Jiang, H.; Guo, Z.; Bai, L.; Wang, L.; Zhang, X.; Zhang, X.; Liu, Y. Tuning Electrode Wettability to Optimize Nanobubble Nucleation and Reaction Rates in Water Electrolysis. Chem. Eng. J. 2025, 523, 168725. [Google Scholar] [CrossRef] [Scilit]
  48. Zhang, J.; Wei, Z.; Zhou, T.; Jin, Y.; Chen, L. Quantifying the Effects of Surface Wettability on Bubble-Mediated Water Electrolysis. Phys. Fluids 2025, 37, 062118. [Google Scholar] [CrossRef] [Scilit]
  49. Fujimura, T.; Hikima, W.; Fukunaka, Y.; Homma, T. Analysis of the Effect of Surface Wettability on Hydrogen Evolution Reaction in Water Electrolysis Using Micro-Patterned Electrodes. Electrochem. Commun. 2019, 101, 43–46. [Google Scholar] [CrossRef] [Scilit]
  50. Rox, H.; Eckert, K.; Ränke, F.; Zschach, L.G.; Yang, X.; Mutschke, G.; Lasagni, A.F.; Baumann, R. Dual Wetting Electrode Surfaces for Alkaline Water Electrolysis. Int. J. Hydrogen Energy 2025, 149, 149928. [Google Scholar] [CrossRef] [Scilit]
  51. Sequeira, C.A.C.; Santos, D.M.F.; Šljukić, B.; Amaral, L. Physics of Electrolytic Gas Evolution. Braz. J. Phys. 2013, 43, 199–208. [Google Scholar] [CrossRef] [Scilit]
  52. Lu, X.; Nie, T.; Li, X.; Jing, L.; Zhang, Y.; Ma, L.; Jing, D. Insight into pH-Controlled Bubble Dynamics on a Pt Electrode during Electrochemical Water Splitting. Phys. Fluids 2023, 35, 103314. [Google Scholar] [CrossRef] [Scilit]
  53. Matsushima, H.; Iida, T.; Fukunaka, Y. Gas Bubble Evolution on Transparent Electrode during Water Electrolysis in a Magnetic Field. Electrochim. Acta 2013, 100, 261–264. [Google Scholar] [CrossRef] [Scilit]
  54. Taqieddin, A.; Allshouse, M.R.; Alshawabkeh, A.N. Editors’ Choice—Critical Review—Mathematical Formulations of Electrochemically Gas-Evolving Systems. J. Electrochem. Soc. 2018, 165, E694. [Google Scholar] [CrossRef] [Scilit]
  55. Zhen, C.; Xue, Y.; Zhang, B.; Wang, Y.; Xing, Y.; Zhao, Q.; Zhao, Q.; Tucker, K.A.; Chen, Z.; Lichtfouse, E.; et al. Bubble Evolution during Hydrogen Production under Normal Gravity and Microgravity: A Review. Int. J. Hydrogen Energy 2025, 163, 150380. [Google Scholar] [CrossRef] [Scilit]
  56. Blander, M.; Katz, J.L. Bubble Nucleation in Liquids. AIChE J. 1975, 21, 833–848. [Google Scholar] [CrossRef] [Scilit]
  57. Sides, P.J. Phenomena and Effects of Electrolytic Gas Evolution. In Modern Aspects of Electrochemistry; White, R.E., Bockris, J.O., Conway, B.E., Eds.; Springer: Boston, MA, USA, 1986; Volume 18, pp. 303–354. ISBN 978-1-4612-9003-2. [Google Scholar]
  58. Lubetkin, S.D. The Fundamentals of Bubble Evolution. Chem. Soc. Rev. 1995, 24, 243–250. [Google Scholar] [CrossRef] [Scilit]
  59. Jones, S.F.; Evans, G.M.; Galvin, K.P. Bubble Nucleation from Gas Cavities—A Review. Adv. Colloid Interface Sci. 1999, 80, 27–50. [Google Scholar] [CrossRef] [Scilit]
  60. Volanschi, A.; Nijman, J.G.H.; Olthuis, W.; Bergveld, P. Microcavity Electrodes Used as Single-Nucleation Site Electrodes for the Electrolysis of Water. Sens. Mater. 1997, 9, 223–240. [Google Scholar]
  61. Raman, A.; Schlautmann, S.; Gardeniers, H.; Fernández Rivas, D. Electrolytic Bubble Coalescence on Hydrophobic Cavity Arrays Determines Departure Radius and Lowers Electrolyte Supersaturation. Small 2025, 21, e05728. [Google Scholar] [CrossRef] [Scilit]
  62. Glas, J.P.; Westwater, J.W. Measurements of the Growth of Electrolytic Bubbles. Int. J. Heat Mass Transf. 1964, 7, 1427–1443. [Google Scholar] [CrossRef] [Scilit]
  63. Saddy, M.; Jameson, G.J. Prediction of Departure Diameter and Bubble Frequency in Nucleate Boiling in Uniformly Superheated Liquids. Int. J. Heat Mass Transf. 1971, 14, 1771–1785. [Google Scholar] [CrossRef] [Scilit]
  64. Brandon, N.P.; Kelsall, G.H. Growth Kinetics of Bubbles Electrogenerated at Microelectrodes. J. Appl. Electrochem. 1985, 15, 475–484. [Google Scholar] [CrossRef] [Scilit]
  65. Hu, X.; Wang, Y.; Guo, L.; Cao, Z. Diffusion-Controlled Growth of Oxygen Bubble Evolved from Nanorod-Array TiO2 Photoelectrode. Adv. Condens. Matter Phys. 2014, 2014, 970891. [Google Scholar] [CrossRef] [Scilit]
  66. Yang, X.; Karnbach, F.; Uhlemann, M.; Odenbach, S.; Eckert, K. Dynamics of Single Hydrogen Bubbles at a Platinum Microelectrode. Langmuir 2015, 31, 8184–8193. [Google Scholar] [CrossRef] [Scilit]
  67. Bouazaze, H.; Cattarin, S.; Huet, F.; Musiani, M.; Nogueira, R.P. Electrochemical Noise Study of the Effect of Electrode Surface Wetting on the Evolution of Electrolytic Hydrogen Bubbles. J. Electroanal. Chem. 2006, 597, 60–68. [Google Scholar] [CrossRef] [Scilit]
  68. Yang, Y.; Pan, L.; Xu, J. Effects of Microgravity on Marangoni Convection and Growth Characteristic of a Single Bubble. Acta Astronaut. 2014, 100, 129–139. [Google Scholar] [CrossRef] [Scilit]
  69. Matsushima, H.; Kiuchi, D.; Fukunaka, Y.; Kuribayashi, K. Single Bubble Growth during Water Electrolysis under Microgravity. Electrochem. Commun. 2009, 11, 1721–1723. [Google Scholar] [CrossRef] [Scilit]
  70. Donose, B.C.; Harnisch, F.; Taran, E. Electrochemically Produced Hydrogen Bubble Probes for Gas Evolution Kinetics and Force Spectroscopy. Electrochem. Commun. 2012, 24, 21–24. [Google Scholar] [CrossRef] [Scilit]
  71. Wang, Y.; Hu, X.; Cao, Z.; Guo, L. Investigations on Bubble Growth Mechanism during Photoelectrochemical and Electrochemical Conversions. Colloids Surf. Physicochem. Eng. Asp. 2016, 505, 86–92. [Google Scholar] [CrossRef] [Scilit]
  72. Bashkatov, A.; Hossain, S.S.; Mutschke, G.; Yang, X.; Rox, H.; Weidinger, I.M.; Eckert, K. On the Growth Regimes of Hydrogen Bubbles at Microelectrodes. Phys. Chem. Chem. Phys. 2022, 24, 26738–26752. [Google Scholar] [CrossRef] [Scilit]
  73. Chandran, P.; Bakshi, S.; Chatterjee, D. Study on the Characteristics of Hydrogen Bubble Formation and Its Transport during Electrolysis of Water. Chem. Eng. Sci. 2015, 138, 99–109. [Google Scholar] [CrossRef] [Scilit]
  74. Vogt, H. The Role of Single-Phase Free Convection in Mass Transfer at Gas Evolving Electrodes—I. Theoretical. Electrochim. Acta 1993, 38, 1421–1426. [Google Scholar] [CrossRef] [Scilit]
  75. Higuera, F.J. A Model of the Growth of Hydrogen Bubbles in the Electrolysis of Water. J. Fluid Mech. 2021, 927, A33. [Google Scholar] [CrossRef] [Scilit]
  76. Oguz, H.N.; Prosperetti, A. Dynamics of Bubble Growth and Detachment from a Needle. J. Fluid Mech. 1993, 257, 111–145. [Google Scholar] [CrossRef] [Scilit]
  77. Robinson, A.J.; Judd, R.L. The Dynamics of Spherical Bubble Growth. Int. J. Heat Mass Transf. 2004, 47, 5101–5113. [Google Scholar] [CrossRef] [Scilit]
  78. Rayleigh, L., VIII. On the Pressure Developed in a Liquid during the Collapse of a Spherical Cavity. Lond. Edinb. Dublin Philos. Mag. J. Sci. 1917, 34, 94–98. [Google Scholar] [CrossRef] [Scilit]
  79. Scriven, L.E. On the Dynamics of Phase Growth. Chem. Eng. Sci. 1959, 10, 1–13. [Google Scholar] [CrossRef] [Scilit]
  80. Darband, G.B.; Aliofkhazraei, M.; Shanmugam, S. Recent Advances in Methods and Technologies for Enhancing Bubble Detachment during Electrochemical Water Splitting. Renew. Sustain. Energy Rev. 2019, 114, 109300. [Google Scholar] [CrossRef] [Scilit]
  81. Schmidt, L.E.; Keim, N.C.; Zhang, W.W.; Nagel, S.R. Memory-Encoding Vibrations in a Disconnecting Air Bubble. Nat. Phys. 2009, 5, 343–346. [Google Scholar] [CrossRef] [Scilit]
  82. Bashkatov, A.; Hossain, S.S.; Yang, X.; Mutschke, G.; Eckert, K. Oscillating Hydrogen Bubbles at Pt Microelectrodes. Phys. Rev. Lett. 2019, 123, 214503. [Google Scholar] [CrossRef] [Scilit]
  83. Hossain, S.S.; Bashkatov, A.; Yang, X.; Mutschke, G.; Eckert, K. Force Balance of Hydrogen Bubbles Growing and Oscillating on a Microelectrode. Phys. Rev. E 2022, 106, 035105. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  84. Xu, W.; Lu, Z.; Sun, X.; Jiang, L.; Duan, X. Superwetting Electrodes for Gas-Involving Electrocatalysis. Acc. Chem. Res. 2018, 51, 1590–1598. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  85. Chen, J.; Guo, L.; Hu, X.; Cao, Z.; Wang, Y. Dynamics of Single Bubble Departure from TiO2 Nanorod-Array Photoelectrode. Electrochim. Acta 2018, 274, 57–66. [Google Scholar] [CrossRef] [Scilit]
  86. Li, Y.; Yang, G.; Yu, S.; Kang, Z.; Mo, J.; Han, B.; Talley, D.A.; Zhang, F.-Y. In-Situ Investigation and Modeling of Electrochemical Reactions with Simultaneous Oxygen and Hydrogen Microbubble Evolutions in Water Electrolysis. Int. J. Hydrogen Energy 2019, 44, 28283–28293. [Google Scholar] [CrossRef] [Scilit]
  87. Liu, Y.; Li, S.; Wu, H.; Shi, Y. Experimental Investigation and Analysis for the Bubble Size Distribution during Alkaline Water Electrolysis by Using a Wire Electrode. DeCarbon 2024, 5, 100052. [Google Scholar] [CrossRef] [Scilit]
  88. Zhang, D.; Zeng, K. Evaluating the Behavior of Electrolytic Gas Bubbles and Their Effect on the Cell Voltage in Alkaline Water Electrolysis. Ind. Eng. Chem. Res. 2012, 51, 13825–13832. [Google Scholar] [CrossRef] [Scilit]
  89. Nie, T.; Li, Z.; Luo, X.; She, Y.; Liang, L.; Xu, Q.; Guo, L. Single Bubble Dynamics on a TiO2 Photoelectrode Surface during Photoelectrochemical Water Splitting. Electrochim. Acta 2022, 436, 141394. [Google Scholar] [CrossRef] [Scilit]
  90. Massing, J.; Mutschke, G.; Baczyzmalski, D.; Hossain, S.S.; Yang, X.; Eckert, K.; Cierpka, C. Thermocapillary Convection during Hydrogen Evolution at Microelectrodes. Electrochim. Acta 2019, 297, 929–940. [Google Scholar] [CrossRef] [Scilit]
  91. Park, S.; Liu, L.; Demirkır, Ç.; van der Heijden, O.; Lohse, D.; Krug, D.; Koper, M.T.M. Solutal Marangoni Effect Determines Bubble Dynamics during Electrocatalytic Hydrogen Evolution. Nat. Chem. 2023, 15, 1532–1540. [Google Scholar] [CrossRef] [Scilit]
  92. Hanafizadeh, P.; Eshraghi, J.; Kosari, E.; Ahmed, W.H. The Effect of Gas Properties on Bubble Formation, Growth, and Detachment. Part. Sci. Technol. 2015, 33, 645–651. [Google Scholar] [CrossRef] [Scilit]
  93. Guan, P.; Jia, L.; Yin, L.; Tan, Z. Bubble Departure Size in Flow Boiling. Heat Mass Transf. 2015, 51, 921–930. [Google Scholar] [CrossRef] [Scilit]
  94. Meulenbroek, A.M.; Vreman, A.W.; Deen, N.G. Competing Marangoni Effects Form a Stagnant Cap on the Interface of a Hydrogen Bubble Attached to a Microelectrode. Electrochim. Acta 2021, 385, 138298. [Google Scholar] [CrossRef] [Scilit]
  95. Yang, X.; Baczyzmalski, D.; Cierpka, C.; Mutschke, G.; Eckert, K. Marangoni Convection at Electrogenerated Hydrogen Bubbles. Phys. Chem. Chem. Phys. 2018, 20, 11542–11548. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  96. Thorncroft, G.E.; Klausner, J.F. Bubble forces and detachment models. Multiph. Sci. Technol. 2001, 13, 42. [Google Scholar] [CrossRef] [Scilit]
  97. Groß, T.F.; Bauer, J.; Ludwig, G.; Rivas, D.F.; Pelz, P.F. Bubble Nucleation from Micro-Crevices in a Shear Flow. Exp. Fluids 2018, 59, 12. [Google Scholar] [CrossRef] [Scilit]
  98. Chen, D.; Pan, L.; Ren, S. Prediction of Bubble Detachment Diameter in Flow Boiling Based on Force Analysis. Nucl. Eng. Des. 2012, 243, 263–271. [Google Scholar] [CrossRef] [Scilit]
  99. Lv, P.; Le The, H.; Eijkel, J.; Van den Berg, A.; Zhang, X.; Lohse, D. Growth and Detachment of Oxygen Bubbles Induced by Gold-Catalyzed Decomposition of Hydrogen Peroxide. J. Phys. Chem. C 2017, 121, 20769–20776. [Google Scholar] [CrossRef] [Scilit]
  100. Karri, S.B.R. Dynamics of bubble departure in micro-gravity. Chem. Eng. Commun. 1988, 70, 127–135. [Google Scholar] [CrossRef] [Scilit]
  101. Vogt, H.; Aras, Ö.; Balzer, R.J. The Limits of the Analogy between Boiling and Gas Evolution at Electrodes. Int. J. Heat Mass Transf. 2004, 47, 787–795. [Google Scholar] [CrossRef] [Scilit]
  102. Iwata, R.; Zhang, L.; Lu, Z.; Gong, S.; Du, J.; Wang, E.N. How Coalescing Bubbles Depart from a Wall. Langmuir 2022, 38, 4371–4377. [Google Scholar] [CrossRef] [Scilit]
  103. Van de Velde, P.; Scheid, B.; Proost, J.; Haut, B. Induced Flow and Coalescence Effects on Hydrogen Bubble Size Distribution around a Single Wire Electrode in Alkaline Water Electrolysis. Chem. Eng. Sci. 2025, 311, 121598. [Google Scholar] [CrossRef] [Scilit]
  104. Zhou, Y.; Feng, J.; Pei, J.; Liu, C.; Zhang, J.; Peng, Z. Bubble Dynamics: From Single-Bubble Growth to Dual-Bubble Coalescence. ACS Nano 2025, 19, 34080–34088. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  105. Feng, Y.; Wang, S.; An, L. Investigation of Bubble Coalescence and Evolution Performance on Electrode Surface. Chem. Eng. Sci. 2025, 309, 121443. [Google Scholar] [CrossRef] [Scilit]
  106. Soto, Á.M.; Maddalena, T.; Fraters, A.; van der Meer, D.; Lohse, D. Coalescence of Diffusively Growing Gas Bubbles. J. Fluid Mech. 2018, 846, 143–165. [Google Scholar] [CrossRef] [Scilit]
  107. Lessard, R.R.; Zieminski, S.A. Bubble Coalescence and Gas Transfer in Aqueous Electrolytic Solutions. Ind. Eng. Chem. Fundam. 1971, 10, 260–269. [Google Scholar] [CrossRef] [Scilit]
  108. Craig, V.S.J.; Ninham, B.W.; Pashley, R.M. The Effect of Electrolytes on Bubble Coalescence in Water. J. Phys. Chem. 1993, 97, 10192–10197. [Google Scholar] [CrossRef] [Scilit]
  109. Craig, V.S.J. Bubble Coalescence and Specific-Ion Effects. Curr. Opin. Colloid Interface Sci. 2004, 9, 178–184. [Google Scholar] [CrossRef] [Scilit]
  110. Pashley, R.M.; Craig, V.S.J. Effects of Electrolytes on Bubble Coalescence. Langmuir 1997, 13, 4772–4774. [Google Scholar] [CrossRef] [Scilit]
  111. Monzon, L.M.A.; Gillen, A.J.; Mobius, M.E.; Coey, J.M.D. Effect of Tetraalkylammonium Cations on Gas Coalescence at a Hydrogen-Evolving Microelectrode. Langmuir 2015, 31, 5738–5747. [Google Scholar] [CrossRef] [Scilit]
  112. Zhang, B.; Wang, Y.; Feng, Y.; Zhen, C.; Liu, M.; Cao, Z.; Zhao, Q.; Guo, L. Coalescence and Detachment of Double Bubbles on Electrode Surface in Photoelectrochemical Water Splitting. Cell Rep. Phys. Sci. 2024, 5, 101837. [Google Scholar] [CrossRef] [Scilit]
  113. Lubetkin, S. The Motion of Electrolytic Gas Bubbles near Electrodes. Electrochim. Acta 2002, 48, 357–375. [Google Scholar] [CrossRef] [Scilit]
  114. Li, J.; Xu, Q.; Nie, T.; Luo, X.; Wang, M.; She, Y.; Guo, L. Coalescence and Detachment of Bubbles for Photoelectrochemical Water Splitting Driven by Linear Gaussian Beam. Int. J. Hydrogen Energy 2024, 93, 1330–1342. [Google Scholar] [CrossRef] [Scilit]
  115. Kuroda, I.; Sakakibara, A.; Sasaki, T.; Murai, Y.; Nagai, N.; Yamamoto, F. PIV Study on Buoyant Bubble Flows in a Small Electrolytic Cell. Jpn. J. Multiph. Flow 2008, 22, 161–174. [Google Scholar] [CrossRef] [Scilit]
  116. Hreiz, R.; Abdelouahed, L.; Fünfschilling, D.; Lapicque, F. Electrogenerated Bubbles Induced Convection in Narrow Vertical Cells: PIV Measurements and Euler–Lagrange CFD Simulation. Chem. Eng. Sci. 2015, 134, 138–152. [Google Scholar] [CrossRef] [Scilit]
  117. Boissonneau, P.; Byrne, P. An Experimental Investigation of Bubble-Induced Free Convection in a Small Electrochemical Cell. J. Appl. Electrochem. 2000, 30, 767–775. [Google Scholar] [CrossRef] [Scilit]
  118. Schiller, L. A Drag Coefficient Correlation. Z. Vereines Dtsch. Ingenieure 1933, 77, 318–320. [Google Scholar]
  119. Saffman, P.G. The Lift on a Small Sphere in a Slow Shear Flow. J. Fluid Mech. 1965, 22, 385–400. [Google Scholar] [CrossRef] [Scilit]
  120. Antal, S.P.; Lahey, R.T.; Flaherty, J.E. Analysis of Phase Distribution in Fully Developed Laminar Bubbly Two-Phase Flow. Int. J. Multiph. Flow 1991, 17, 635–652. [Google Scholar] [CrossRef] [Scilit]
  121. Krikke, I.R.C. Modeling the Effect of Dissolved Gas on the Bubble Layer Along a Vertical Gasevolving Electrode. Master’s Thesis, Delft University of Technology, Delft, The Netherlands, 2021. [Google Scholar]
  122. Görtz, J.; Seiler, J.; Jupke, A. Bubble up: Tracking down the Vertical Velocity of Oxygen Bubbles in Parallel Plate Electrolyzers Using CNN. Int. J. Multiph. Flow 2024, 177, 104849. [Google Scholar] [CrossRef] [Scilit]
  123. Görtz, J.; Jupke, A. Exploring the Bubble-Electrolyte Interplay in Membrane Electrolyzers: PIV Measurement of Electrolyte Flow Regimes. Int. J. Multiph. Flow 2026, 195, 105550. [Google Scholar] [CrossRef] [Scilit]
  124. Vogt, H. Instability of the Two-Phase Flow in Vertical Interelectrode Gaps. J. Appl. Electrochem. 1999, 29, 1155–1159. [Google Scholar] [CrossRef] [Scilit]
  125. Burns, A.; Frank, T.; Hamill, I.; Shi, J.-M. The Favre Averaged Drag Model for Turbulent Dispersion in Eulerian Multi-Phase Flows; ICMF: Yokohama, Japan, 2004; Volume 392. [Google Scholar]
  126. Aldas, K.; Pehlivanoglu, N.; Mat, M. Numerical and Experimental Investigation of Two-Phase Flow in an Electrochemical Cell. Int. J. Hydrogen Energy 2008, 33, 3668–3675. [Google Scholar] [CrossRef] [Scilit]
  127. Diehl de Oliveira, J.; Cardoso, E.M.; Rodrigues de Souza, R.; Copetti, J.B.; Varón, L.M.; Simões Moreira, J.R. On Fluctuations in Velocity Fields during Convective Mass Transfer in Hydrogen Generation through Water Electrolysis. Int. J. Hydrogen Energy 2024, 80, 394–405. [Google Scholar] [CrossRef] [Scilit]
  128. Hine, F.; Yasuda, M.; Nakamura, R.; Noda, T. Hydrodynamic Studies of Bubble Effects on the IR-drops in a Vertical Rectangular Cell. J. Electrochem. Soc. 1975, 122, 1185. [Google Scholar] [CrossRef] [Scilit]
  129. Janssen, L.J.J.; Sillen, C.W.M.P.; Barendrecht, E.; Van Stralen, S.J.D. Bubble Behaviour during Oxygen and Hydrogen Evolution at Transparent Electrodes in KOH Solution. Electrochim. Acta 1984, 29, 633–642. [Google Scholar] [CrossRef] [Scilit]
  130. Bongenaar-Schlenter, B.E.; Janssen, L.J.J.; Van Stralen, S.J.D.; Barendrecht, E. The Effect of the Gas Void Distribution on the Ohmic Resistance during Water Electrolytes. J. Appl. Electrochem. 1985, 15, 537–548. [Google Scholar] [CrossRef] [Scilit]
  131. Weijs, M.P.M.G.; Janssen, L.J.J.; Visser, G.J. Ohmic Resistance of Solution in a Vertical Gas-Evolving Cell. J. Appl. Electrochem. 1997, 27, 371–378. [Google Scholar] [CrossRef] [Scilit]
  132. Riegel, H.; Mitrovic, J.; Stephan, K. Role of Mass Transfer on Hydrogen Evolution in Aqueous Media. J. Appl. Electrochem. 1998, 28, 10–17. [Google Scholar] [CrossRef] [Scilit]
  133. Pang, X.; Davis, J.T.; Harvey, A.D.; Esposito, D.V. Framework for Evaluating the Performance Limits of Membraneless Electrolyzers. Energy Environ. Sci. 2020, 13, 3663–3678. [Google Scholar] [CrossRef] [Scilit]
  134. Tobias, C.W. Effect of Gas Evolution on Current Distribution and Ohmic Resistance in Electrolyzers. J. Electrochem. Soc. 1959, 106, 833. [Google Scholar] [CrossRef] [Scilit]
  135. Venkatesh, N.K.; Krikke, I.R.C.; Valle, N.; Haverkort, J.W. Bubble Growth after Release from an Electrode: A Validated CFD Model. Electrochim. Acta 2026, 547, 147827. [Google Scholar] [CrossRef] [Scilit]
  136. Abdelouahed, L.; Hreiz, R.; Poncin, S.; Valentin, G.; Lapicque, F. Hydrodynamics of Gas Bubbles in the Gap of Lantern Blade Electrodes without Forced Flow of Electrolyte: Experiments and CFD Modelling. Chem. Eng. Sci. 2014, 111, 255–265. [Google Scholar] [CrossRef] [Scilit]
  137. Zhang, H.; Zhang, R.; Chen, Z.; Yuan, F.; Yang, Q.; Liu, B. Experimental and Theoretical Study on the Gas Holdup Feature in a 1.5-m Tall Alkaline Water Electrolytic Cell. AIChE J. 2025, 71, e18814. [Google Scholar] [CrossRef] [Scilit]
  138. Dedigama, I.; Angeli, P.; Van Dijk, N.; Millichamp, J.; Tsaoulidis, D.; Shearing, P.R.; Brett, D.J.L. Current Density Mapping and Optical Flow Visualisation of a Polymer Electrolyte Membrane Water Electrolyser. J. Power Sources 2014, 265, 97–103. [Google Scholar] [CrossRef] [Scilit]
  139. Majasan, J.O.; Cho, J.I.S.; Dedigama, I.; Tsaoulidis, D.; Shearing, P.; Brett, D.J.L. Two-Phase Flow Behaviour and Performance of Polymer Electrolyte Membrane Electrolysers: Electrochemical and Optical Characterisation. Int. J. Hydrogen Energy 2018, 43, 15659–15672. [Google Scholar] [CrossRef] [Scilit]
  140. Lu, X.; Yadav, D.; Zhou, L.; Zhou, Y.; Liu, Q.; Li, X.; Ma, L.; Jing, D. Combined Effects of Bubble Size Ratio on Coalescence-Driven Dynamics and Electrode Dimensions on Electrolytic Performance. Langmuir 2025, 41, 20917–20928. [Google Scholar] [CrossRef] [Scilit]
  141. Görtz, J.; Seiler, J.; Kolmer, P.; Jupke, A. Raising the Curtain: Bubble Size Measurement inside Parallel Plate Electrolyzers. Chem. Eng. Sci. 2024, 286, 119550. [Google Scholar] [CrossRef] [Scilit]
  142. Hadikhani, P.; Hashemi, S.M.H.; Schenk, S.A.; Psaltis, D. A Membrane-Less Electrolyzer with Porous Walls for High Throughput and Pure Hydrogen Production. Sustain. Energy Fuels 2021, 5, 2419–2432. [Google Scholar] [CrossRef] [Scilit]
  143. Ikeda, H.; Misumi, R.; Kojima, Y.; Haleem, A.A.; Kuroda, Y.; Mitsushima, S. Microscopic High-Speed Video Observation of Oxygen Bubble Generation Behavior and Effects of Anode Electrode Shape on OER Performance in Alkaline Water Electrolysis. Int. J. Hydrogen Energy 2022, 47, 11116–11127. [Google Scholar] [CrossRef] [Scilit]
  144. Liu, Y.; Chen, M.; Mo, J.; Hao, H.; Tan, H.; Wang, X.; Jiang, P.; Li, J.; Wang, Y.; Deng, Z. Visual Experimental Research of Two-Phase Flow in Long Straight Anode Channels with Different Widths in a Polymer Electrolyte Membrane Water Electrolysis Cell. J. Power Sources 2025, 646, 237258. [Google Scholar] [CrossRef] [Scilit]
  145. Rox, H.; Bashkatov, A.; Yang, X.; Loos, S.; Mutschke, G.; Gerbeth, G.; Eckert, K. Bubble Size Distribution and Electrode Coverage at Porous Nickel Electrodes in a Novel 3-Electrode Flow-through Cell. Int. J. Hydrogen Energy 2023, 48, 2892–2905. [Google Scholar] [CrossRef] [Scilit]
  146. Chen, Z.; Meng, C.; Ruan, H.; Li, R.; Xu, X.; Liu, B.; Yang, Q. Removal of Bubbles from Eletrodes in a Planar Cyclonic Electrolyzer. Chem. Eng. Process.—Process Intensif. 2022, 181, 109133. [Google Scholar] [CrossRef] [Scilit]
  147. Abdelghani-Idrissi, S.; Dubouis, N.; Grimaud, A.; Stevens, P.; Toussaint, G.; Colin, A. Effect of Electrolyte Flow on a Gas Evolution Electrode. Sci. Rep. 2021, 11, 4677. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  148. Sinapan, I.; Lin-Kwong-Chon, C.; Damour, C.; Kadjo, J.-J.A.; Benne, M. Oxygen Bubble Dynamics in PEM Water Electrolyzers with a Deep-Learning-Based Approach. Hydrogen 2023, 4, 556–572. [Google Scholar] [CrossRef] [Scilit]
  149. Coenen, E.L.J.; Janssen, L.J.J. Voidage of Bulk Solution in a Tall Vertical Gasevolving Cell. J. Appl. Electrochem. 1997, 27, 1143–1148. [Google Scholar] [CrossRef] [Scilit]
  150. Hadikhani, P.; Hashemi, S.M.H.; Psaltis, D. The Impact of Surfactants on the Inertial Separation of Bubbles in Microfluidic Electrolyzers. J. Electrochem. Soc. 2020, 167, 134504. [Google Scholar] [CrossRef] [Scilit]
  151. Luo, X.; Xu, Q.; Nie, T.; She, Y.; Ye, X.; Guo, L. Influence of Subatmospheric Pressure on Bubble Evolution on the TiO2 Photoelectrode Surface. Phys. Chem. Chem. Phys. 2023, 25, 16086–16104. [Google Scholar] [CrossRef] [Scilit]
  152. de Jonge, R.M.; Barendrecht, E.; Janssen, L.J.J.; van Stralen, S.J.D. Gas Bubble Behaviour and Electrolyte Resistance during Water Electrolysis. Int. J. Hydrogen Energy 1982, 7, 883–894. [Google Scholar] [CrossRef] [Scilit]
  153. Amores, E. Bubble Characterization in an Electrolysis Cell Using a Flow Visualization System. In Proceedings of the Descripción de la publicación International Conference on Electrolysis (ICE 2017), Copenhague, Denmark, 12–15 June 2017. [Google Scholar]
  154. Ham, C.T.; Shrestha, P.; Kober, L.; Gasilov, S.; Webb, M.A.; Bazylak, A. The Role of Operating Temperature on Pore-Scale Gas Transport in Polymer Electrolyte Membrane Electrolyzers. Adv. Sci. 2025, 12, e07606. [Google Scholar] [CrossRef] [Scilit]
  155. Selamet, O.F.; Pasaogullari, U.; Spernjak, D.; Hussey, D.S.; Jacobson, D.L.; Mat, M. In Situ Two-Phase Flow Investigation of Proton Exchange Membrane (PEM) Electrolyzer by Simultaneous Optical and Neutron Imaging. ECS Trans. 2011, 41, 349. [Google Scholar] [CrossRef] [Scilit]
  156. Nagai, N.; Takeuchi, M.; Kimura, T.; Oka, T. Existence of Optimum Space between Electrodes on Hydrogen Production by Water Electrolysis. Int. J. Hydrogen Energy 2003, 28, 35–41. [Google Scholar] [CrossRef] [Scilit]
  157. Hine, F.; Murakami, K. Bubble Effects on the Solution IR Drop in a Vertical Electrolyzer under Free and Forced Convection. J. Electrochem. Soc. 1980, 127, 292. [Google Scholar] [CrossRef] [Scilit]
  158. Wendt, H.; Imarisio, G. Nine Years of Research and Development on Advanced Water Electrolysis. A Review of the Research Programme of the Commission of the European Communities. J. Appl. Electrochem. 1988, 18, 1–14. [Google Scholar] [CrossRef] [Scilit]
  159. Haverkort, J.W.; Rajaei, H. Voltage Losses in Zero-Gap Alkaline Water Electrolysis. J. Power Sources 2021, 497, 229864. [Google Scholar] [CrossRef] [Scilit]
  160. Dung, O.-Y.; Boden, S.; Vreman, A.W.; Deen, N.G.; Schubert, M.; Tang, Y. X-Ray Measurements of Gas Distribution in a Zero Gap Alkaline Water Electrolyzer. Int. J. Hydrogen Energy 2025, 105, 835–844. [Google Scholar] [CrossRef] [Scilit]
  161. Ito, H.; Maeda, T.; Nakano, A.; Hasegawa, Y.; Yokoi, N.; Hwang, C.M.; Ishida, M.; Kato, A.; Yoshida, T. Effect of Flow Regime of Circulating Water on a Proton Exchange Membrane Electrolyzer. Int. J. Hydrogen Energy 2010, 35, 9550–9560. [Google Scholar] [CrossRef] [Scilit]
  162. Lin, R.; Lu, Y.; Xu, J.; Huo, J.; Cai, X. Investigation on Performance of Proton Exchange Membrane Electrolyzer with Different Flow Field Structures. Appl. Energy 2022, 326, 120011. [Google Scholar] [CrossRef] [Scilit]
  163. Trabold, T.A. Minichannels in Polymer Electrolyte Membrane Fuel Cells. Heat Transf. Eng. 2005, 26, 3–12. [Google Scholar] [CrossRef] [Scilit]
  164. Reshetenko, T.V.; Bender, G.; Bethune, K.; Rocheleau, R. A Segmented Cell Approach for Studying the Effects of Serpentine Flow Field Parameters on PEMFC Current Distribution. Electrochim. Acta 2013, 88, 571–579. [Google Scholar] [CrossRef] [Scilit]
  165. Huo, X.; Shan, G.; Yang, L.; Gao, L.; Wang, Y.; Zhang, M.; Fu, Y.; Li, W.; Zhang, J. Impedance Analysis of Alkaline Water Electrolysis Based on Distribution of Relaxation Time. Int. J. Hydrogen Energy 2024, 53, 684–697. [Google Scholar] [CrossRef] [Scilit]
  166. Minnaar, C.; De Beer, F.; Bessarabov, D. Current Density Distribution of Electrolyzer Flow Fields: In Situ Current Mapping and Neutron Radiography. Energy Fuels 2020, 34, 1014–1023. [Google Scholar] [CrossRef] [Scilit]
  167. Wang, T.; Wang, J.; Wang, P.; Wang, F.; Liu, L.; Guo, H. Non-Uniform Liquid Flow Distribution in an Alkaline Water Electrolyzer with Concave-Convex Bipolar Plate (CCBP): A Numerical Study. Int. J. Hydrogen Energy 2023, 48, 12200–12214. [Google Scholar] [CrossRef] [Scilit]
  168. Wang, T.; Wang, J.; Wang, P.; Ren, Z.; Yan, X.; Wang, W.; Guo, W. Plate Structure Design Guideline for Commercial Alkaline Water Electrolyzers (AWEs) with Improved Liquid Flow Uniformity: Multi-Scale Quantitative Criteria and Experimental Validation. Int. J. Hydrogen Energy 2024, 49, 907–924. [Google Scholar] [CrossRef] [Scilit]
  169. Rivera, F.F.; Castañeda, L.; Hidalgo, P.E.; Orozco, G. Study of Hydrodynamics at AsahiTM Prototype Electrochemical Flow Reactor, Using Computational Fluid Dynamics and Experimental Characterization Techniques. Electrochim. Acta 2017, 245, 107–117. [Google Scholar] [CrossRef] [Scilit]
  170. Wang, M.; Nie, T.; She, Y.; Tao, L.; Luo, X.; Xu, Q.; Guo, L. Study on the Behavior of Single Oxygen Bubble Regulated by Salt Concentration in Photoelectrochemical Water Splitting. Int. J. Hydrogen Energy 2023, 48, 23387–23401. [Google Scholar] [CrossRef] [Scilit]
  171. Kiuchi, D.; Matsushima, H.; Fukunaka, Y.; Kuribayashi, K. Ohmic Resistance Measurement of Bubble Froth Layer in Water Electrolysis under Microgravity. J. Electrochem. Soc. 2006, 153, E138. [Google Scholar] [CrossRef] [Scilit]
  172. Zhao, B.; Lee, C.; Lee, J.K.; Fahy, K.F.; LaManna, J.M.; Baltic, E.; Jacobson, D.L.; Hussey, D.S.; Bazylak, A. Superhydrophilic Porous Transport Layer Enhances Efficiency of Polymer Electrolyte Membrane Electrolyzers. Cell Rep. Phys. Sci. 2021, 2, 100580. [Google Scholar] [CrossRef] [Scilit]
  173. Yang, Y.; Ouyang, T.; Tao, D.; Xu, B.; Li, J.; Huang, J.; Zhang, L.; Ye, D.; Chen, R.; Zhu, X.; et al. Improving Mass Transfer with Surface Patterning of the Porous Transport Layer for PEM Water Electrolysis. Cell Rep. Phys. Sci. 2025, 6, 102433. [Google Scholar] [CrossRef] [Scilit]
  174. Manninen, M.; Taivassalo, V.; Energy, V.; Kallio, S. On the Mixture Model for Multiphase Flow; VTT Publications: Espoo, Finland, 1996. [Google Scholar]
  175. Zuber, N.; Findlay, J.A. Average Volumetric Concentration in Two-Phase Flow Systems. J. Heat Transf. 1965, 87, 453–468. [Google Scholar] [CrossRef] [Scilit]
  176. Dahlkild, A.A. Modelling the Two-Phase Flow and Current Distribution along a Vertical Gas-Evolving Electrode. J. Fluid Mech. 2001, 428, 249–272. [Google Scholar] [CrossRef] [Scilit]
  177. Wedin, R.; Dahlkild, A.A. On the Transport of Small Bubbles under Developing Channel Flow in a Buoyant Gas-Evolving Electrochemical Cell. Ind. Eng. Chem. Res. 2001, 40, 5228–5233. [Google Scholar] [CrossRef] [Scilit]
  178. Nie, J.; Chen, Y. Numerical Modeling of Three-Dimensional Two-Phase Gas–Liquid Flow in the Flow Field Plate of a PEM Electrolysis Cell. Int. J. Hydrogen Energy 2010, 35, 3183–3197. [Google Scholar] [CrossRef] [Scilit]
  179. Schillings, J.; Doche, O.; Deseure, J. Modeling of Electrochemically Generated Bubbly Flow under Buoyancy-Driven and Forced Convection. Int. J. Heat Mass Transf. 2015, 85, 292–299. [Google Scholar] [CrossRef] [Scilit]
  180. Nicolai, H.; Herzhaft, B.; Hinch, E.J.; Oger, L.; Guazzelli, E. Particle Velocity Fluctuations and Hydrodynamic Self-Diffusion of Sedimenting Non-Brownian Spheres. Phys. Fluids 1995, 7, 12–23. [Google Scholar] [CrossRef] [Scilit]
  181. Leighton, D.; Acrivos, A. Measurement of Shear-Induced Self-Diffusion in Concentrated Suspensions of Spheres. J. Fluid Mech. 1987, 177, 109–131. [Google Scholar] [CrossRef] [Scilit]
  182. Schaflinger, U. Centrifugal Separation of a Mixture. Fluid Dyn. Res. 1990, 6, 213. [Google Scholar] [CrossRef] [Scilit]
  183. Rajora, A.; Haverkort, J.W. An Analytical Multiphase Flow Model for Parallel Plate Electrolyzers. Chem. Eng. Sci. 2022, 260, 117823. [Google Scholar] [CrossRef] [Scilit]
  184. Huang, D.; Zhong, Z.; Ai, X.; Hu, K.; Xiong, B.; Wen, Q.; Fang, J.; Cheng, S. Size Design Strategy for Scaling up Alkaline Water Electrolysis Stack Integrated with Renewable Energy Source: A Multiphysics Modeling Approach. Energy Convers. Manag. 2024, 300, 117955. [Google Scholar] [CrossRef] [Scilit]
  185. Lee, J.; Alam, A.; Park, C.; Yoon, S.; Ju, H. Modeling of Gas Evolution Processes in Porous Electrodes of Zero-Gap Alkaline Water Electrolysis Cells. Fuel 2022, 315, 123273. [Google Scholar] [CrossRef] [Scilit]
  186. van der Does, W.L.; Valle, N.; Haverkort, J.W. Multiphase Alkaline Water Electrolysis Simulations: The Need for a Solid Pressure Model to Explain Experimental Bubble Overpotentials. Int. J. Hydrogen Energy 2025, 102, 295–303. [Google Scholar] [CrossRef] [Scilit]
  187. Drew, D.A. Mathematical Modeling of Two-Phase Flow. Annu. Rev. Fluid Mech. 1983, 15, 261–291. [Google Scholar] [CrossRef] [Scilit]
  188. Ishii, M.; Mishima, K. Two-Fluid Model and Hydrodynamic Constitutive Relations. Nucl. Eng. Des. 1984, 82, 107–126. [Google Scholar] [CrossRef] [Scilit]
  189. Mat, M.D.; Aldas, K.; Ilegbusi, O.J. A Two-Phase Flow Model for Hydrogen Evolution in an Electrochemical Cell. Int. J. Hydrogen Energy 2004, 29, 1015–1023. [Google Scholar] [CrossRef] [Scilit]
  190. El-Askary, W.A.; Sakr, I.M.; Ibrahim, K.A.; Balabel, A. Hydrodynamics Characteristics of Hydrogen Evolution Process through Electrolysis: Numerical and Experimental Studies. Energy 2015, 90, 722–737. [Google Scholar] [CrossRef] [Scilit]
  191. Dreoni, M.; Balduzzi, F.; Ferrara, G.; Bianchini, A. Accuracy Assessment of the Eulerian Two-Phase Model for the CFD Simulation of Gas Bubbles Dynamics in Alkaline Electrolyzers. J. Phys. Conf. Ser. 2022, 2385, 12040. [Google Scholar] [CrossRef] [Scilit]
  192. Zarghami, A.; Deen, N.G.; Vreman, A.W. CFD Modeling of Multiphase Flow in an Alkaline Water Electrolyzer. Chem. Eng. Sci. 2020, 227, 115926. [Google Scholar] [CrossRef] [Scilit]
  193. Mohamed Mohsin, H.; Zhuo, Y.; Shen, Y. Eulerian-Eulerian-VOF Multifluid Modelling of Liquid–Gas Reacting Flow for Hydrogen Generation in an Alkaline Water Electrolyser. Fuel 2024, 373, 132164. [Google Scholar] [CrossRef] [Scilit]
  194. Bai, J.; Guan, X.; Yang, N. Three-Dimensional CFD Simulation of Alkaline Electrolyzers: Flow Pattern and Electric Field. Chem. Eng. J. 2025, 515, 163908. [Google Scholar] [CrossRef] [Scilit]
  195. Dreoni, M.; Balduzzi, F.; Ferro, F.M.; Panichi, K.; Ponticorvo, E.; Ferrara, G.; Bianchini, A. Towards a Comprehensive, High-Fidelity, Multi-Physics Simulation Framework for Alkaline Water Electrolyzers. Int. J. Hydrogen Energy 2025, 111, 238–250. [Google Scholar] [CrossRef] [Scilit]
  196. Feng, Z.; Zheng, L.; Wang, G.; Guo, K.; Liu, C. Investigation of the Electrochemical Performance in Alkaline Water Electrolysis Cells Based on a 3D Multiphysics Model: Effect of Flow Field and Electric Field. Appl. Energy 2025, 384, 125447. [Google Scholar] [CrossRef] [Scilit]
  197. Alexiadis, A.; Dudukovic, M.P.; Ramachandran, P.; Cornell, A.; Wanngård, J.; Bokkers, A. Liquid–Gas Flow Patterns in a Narrow Electrochemical Channel. Chem. Eng. Sci. 2011, 66, 2252–2260. [Google Scholar] [CrossRef] [Scilit]
  198. Le Bideau, D.; Mandin, P.; Benbouzid, M.; Kim, M.; Sellier, M.; Ganci, F.; Inguanta, R. Eulerian Two-Fluid Model of Alkaline Water Electrolysis for Hydrogen Production. Energies 2020, 13, 3394. [Google Scholar] [CrossRef] [Scilit]
  199. Colli, A.N.; Bisang, J.M. Current and Potential Distribution in Two-Phase (Gas Evolving) Electrochemical Reactors by the Finite Volume Method. J. Electrochem. Soc. 2022, 169, 34524. [Google Scholar] [CrossRef] [Scilit]
  200. Jiang, Y.; Li, Y.; Ding, Y.; Hu, S.; Dang, J.; Yang, F.; Ouyang, M. Simulation and Experiment Study on Two-Phase Flow Characteristics of Proton Exchange Membrane Electrolysis Cell. J. Power Sources 2023, 553, 232303. [Google Scholar] [CrossRef] [Scilit]
  201. Zhang, Z.; Jin, L.; Deng, L.; Li, W.; Liu, M.; Geng, Z.; Zhang, C. Three-Dimensional Simulation of Two-Phase Flow Distribution in Spherical Concave-Convex Shaped Flow Field for Alkaline Water Electrolyzer. Int. J. Hydrogen Energy 2023, 48, 33401–33410. [Google Scholar] [CrossRef] [Scilit]
  202. Li, J.; Liang, H.; Abdullah Rehan, M.; Li, G. Numerical Simulation and Analysis of a Two-Phase Flow Model Considering Bubble Coverage for Alkaline Electrolytic Water. Appl. Therm. Eng. 2024, 245, 122890. [Google Scholar] [CrossRef] [Scilit]
  203. Liang, F.; van de Krol, R.; Abdi, F.F. Assessing Elevated Pressure Impact on Photoelectrochemical Water Splitting via Multiphysics Modeling. Nat. Commun. 2024, 15, 4944. [Google Scholar] [CrossRef] [Scilit]
  204. Lu, R.; Wang, J.; Wang, Z.; Hua, M.; Pan, X. Three-Dimensional Simulation Study of Bubble Distribution Characteristics and Bubble-Flow Field Coupling Effects in Alkaline Water Electrolyzer. Fuel 2026, 404, 136379. [Google Scholar] [CrossRef] [Scilit]
  205. Delnoij, E.; Lammers, F.A.; Kuipers, J.A.M.; van Swaaij, W.P.M. Dynamic Simulation of Dispersed Gas-Liquid Two-Phase Flow Using a Discrete Bubble Model. Chem. Eng. Sci. 1997, 52, 1429–1458. [Google Scholar] [CrossRef] [Scilit]
  206. Laín, S.; Bröder, D.; Sommerfeld, M.; Göz, M.F. Modelling Hydrodynamics and Turbulence in a Bubble Column Using the Euler–Lagrange Procedure. Int. J. Multiph. Flow 2002, 28, 1381–1407. [Google Scholar] [CrossRef] [Scilit]
  207. Mandin, P.; Aissa, A.A.; Roustan, H.; Hamburger, J.; Picard, G. Two-Phase Electrolysis Process: From the Bubble to the Electrochemical Cell Properties. Chem. Eng. Process. Process Intensif. 2008, 47, 1926–1932. [Google Scholar] [CrossRef] [Scilit]
  208. Nierhaus, T.; Parys, H.V.; Dehaeck, S.; van Beeck, J.; Deconinck, H.; Deconinck, J.; Hubin, A. Simulation of the Two-Phase Flow Hydrodynamics in an IRDE Reactor. J. Electrochem. Soc. 2009, 156, P139. [Google Scholar] [CrossRef] [Scilit]
  209. Cao, X.; Zhao, N.; Zhang, S.; Zhou, L.; Hu, Y.; Yun, J. Investigation of the Hydrogen Bubble Effect on the Overpotential in an Alkaline Water Electrolyzer. Int. J. Hydrogen Energy 2024, 49, 47–57. [Google Scholar] [CrossRef] [Scilit]
  210. Hirt, C.W.; Nichols, B.D. Volume of Fluid (VOF) Method for the Dynamics of Free Boundaries. J. Comput. Phys. 1981, 39, 201–225. [Google Scholar] [CrossRef] [Scilit]
  211. Peskin, C.S. Flow Patterns around Heart Valves: A Numerical Method. J. Comput. Phys. 1972, 10, 252–271. [Google Scholar] [CrossRef] [Scilit]
  212. Lafmejani, S.S.; Olesen, A.C.; Kær, S.K. VOF Modelling of Gas–Liquid Flow in PEM Water Electrolysis Cell Micro-Channels. Int. J. Hydrogen Energy 2017, 42, 16333–16344. [Google Scholar] [CrossRef] [Scilit]
  213. Wong, X.Y.; Zhuo, Y.; Shen, Y. Numerical Analysis of Hydrogen Bubble Behavior in a Zero-Gap Alkaline Water Electrolyzer Flow Channel. Ind. Eng. Chem. Res. 2021, 60, 12429–12446. [Google Scholar] [CrossRef] [Scilit]
  214. Zhou, H.; Meng, K.; Chen, W.; Chen, B. Exploratory Research on Bubbles Migration Behavior and Mass Transfer Capacity Evaluation of Proton Exchange Membrane Water Electrolyzer Based on a Volume of Fluid-Coupled Electrochemical Model. Energy Convers. Manag. 2023, 290, 117217. [Google Scholar] [CrossRef] [Scilit]
  215. Sepahi, F.; Pande, N.; Chong, K.L.; Mul, G.; Verzicco, R.; Lohse, D.; Mei, B.T.; Krug, D. The Effect of Buoyancy Driven Convection on the Growth and Dissolution of Bubbles on Electrodes. Electrochim. Acta 2022, 403, 139616. [Google Scholar] [CrossRef] [Scilit]
  216. Khalighi, F.; Deen, N.G.; Tang, Y.; Vreman, A.W. Hydrogen Bubble Growth in Alkaline Water Electrolysis: An Immersed Boundary Simulation Study. Chem. Eng. Sci. 2023, 267, 118280. [Google Scholar] [CrossRef] [Scilit]
  217. Liu, H.; Pan, L.; Wen, J. Numerical Simulation of Hydrogen Bubble Growth at an Electrode Surface. Can. J. Chem. Eng. 2015, 94, 192–199. [Google Scholar] [CrossRef] [Scilit]
  218. Niblett, D.; Elwan, H.A.; Mamlouk, M. Membraneless Water Electrolysis Enabled by Flow and Porous Electrode Design for Bubble Separation. Chem. Eng. J. 2025, 519, 163444. [Google Scholar] [CrossRef] [Scilit]
  219. Colli, A.N.; Bisang, J.M. Tertiary Current and Potential Distribution Including Laminar/Turbulent Convection, Diffusion, and Migration by the Finite Volume Method Using OpenFOAM. Ind. Eng. Chem. Res. 2021, 60, 11927–11941. [Google Scholar] [CrossRef] [Scilit]
  220. Alexiadis, A.; Dudukovic, M.P.; Ramachandran, P.; Cornell, A.; Wanngård, J.; Bokkers, A. Transition to Pseudo-Turbulence in a Narrow Gas-Evolving Channel. Theor. Comput. Fluid Dyn. 2012, 26, 551–564. [Google Scholar] [CrossRef] [Scilit]
  221. Valle, N.; Haverkort, J.W. Self-Similar Solution for Laminar Bubbly Flow Evolving from a Vertical Plate. J. Fluid Mech. 2024, 996, A38. [Google Scholar] [CrossRef] [Scilit]
  222. Li, Q.; Bao, C.; Jiang, Z.; Zhang, X.; Ding, T.; Fang, C.; Ouyang, M. Numerical Study on Oxygen Transport Pattern in Porous Transport Layer of Proton Exchange Membrane Electrolysis Cells. eTransportation 2023, 15, 100210. [Google Scholar] [CrossRef] [Scilit]
  223. Vogt, H.; Balzer, R.J. The Bubble Coverage of Gas-Evolving Electrodes in Stagnant Electrolytes. Electrochim. Acta 2005, 50, 2073–2079. [Google Scholar] [CrossRef] [Scilit]
  224. Eigeldinger, J.; Vogt, H. The Bubble Coverage of Gas-Evolving Electrodes in a Flowing Electrolyte. Electrochim. Acta 2000, 45, 4449–4456. [Google Scholar] [CrossRef] [Scilit]
  225. Balzer, R.J.; Vogt, H. Effect of Electrolyte Flow on the Bubble Coverage of Vertical Gas-Evolving Electrodes. J. Electrochem. Soc. 2003, 150, E11. [Google Scholar] [CrossRef] [Scilit]
  226. Xin, S.; LiJun, X.; Di, Z.; Bing, H.; LuXiang, M. Electrochemical Performance Study of Proton Exchange Membrane Electrolyzer Considering the Effect of Bubble Coverage. Int. J. Hydrogen Energy 2023, 48, 27079–27094. [Google Scholar] [CrossRef] [Scilit]
  227. Immerz, C.; Bensmann, B.; Trinke, P.; Suermann, M.; Hanke-Rauschenbach, R. Local Current Density and Electrochemical Impedance Measurements within 50 cm Single-Channel PEM Electrolysis Cell. J. Electrochem. Soc. 2018, 165, F1292. [Google Scholar] [CrossRef] [Scilit]
  228. Deng, X.; Yang, F.; Li, Y.; Dang, J.; Ouyang, M. Quantitative Study on Gas Evolution Effects under Large Current Density in Zero-Gap Alkaline Water Electrolyzers. J. Power Sources 2023, 555, 232378. [Google Scholar] [CrossRef] [Scilit]
  229. Ruiz Diaz, D.F.; Wang, Y. Performance Loss Due to Gas Coverage on Catalyst Surface in Polymer Electrolyte Membrane Electrolysis Cell. eTransportation 2023, 18, 100263. [Google Scholar] [CrossRef] [Scilit]
  230. Bruggeman, D.A.G. Berechnung Verschiedener Physikalischer Konstanten von Heterogenen Substanzen. I. Dielektrizitätskonstanten Und Leitfähigkeiten Der Mischkörper Aus Isotropen Substanzen. Ann. Phys. 1935, 416, 636–664. [Google Scholar] [CrossRef] [Scilit]
  231. de Groot, M.T.; Vreman, A.W. Ohmic Resistance in Zero Gap Alkaline Electrolysis with a Zirfon Diaphragm. Electrochim. Acta 2021, 369, 137684. [Google Scholar] [CrossRef] [Scilit]
  232. Alkhaldi, S.; Aziz, M.; Amrite, A.; Prasad, A.K. Parametric Study of PEM Water Electrolyzer Performance. J. Appl. Electrochem. 2025, 55, 327–343. [Google Scholar] [CrossRef] [Scilit]
  233. Ikeda, H.; Misumi, R.; Nishiki, Y.; Kuroda, Y.; Mitsushima, S. A Dual Bubble Layer Model for Reactant Transfer Resistance in Alkaline Water Electrolysis. Electrochim. Acta 2022, 430, 141053. [Google Scholar] [CrossRef] [Scilit]
  234. Wang, B.; Hao, M.; Kirk, D.; Guay, D.; Thorpe, S. Analysis of Bubble Management Performance Using Dual Bubble Layer Model and Electrochemical Impedance Spectroscopy. Electrochim. Acta 2025, 518, 145784. [Google Scholar] [CrossRef] [Scilit]
  235. Fouad, M.G.; Sedahmed, G.H. Mass Transfer at Horizontal Gas-Evolving Electrodes. Electrochim. Acta 1973, 18, 55–58. [Google Scholar] [CrossRef] [Scilit]
  236. Sigrist, L.; Dossenbach, O.; Ibl, N. Mass Transport in Electrolytic Cells with Gas Sparging. Int. J. Heat Mass Transf. 1979, 22, 1393–1399. [Google Scholar] [CrossRef] [Scilit]
  237. Giron, F.; Valentin, G.; Lebouche, M.; Storck, A. Mass and Momentum Transfer Enhancement Due to Electrogenerated Gas Bubbles. J. Appl. Electrochem. 1985, 15, 557–566. [Google Scholar] [CrossRef] [Scilit]
  238. Janssen, L.J.J.; Barendrecht, E. Mechanism of Mass Transfer of Indicator Ions to an Oxygen-Evolving and a Hydrogen-Evolving Electrode in Alkaline Solution. Electrochim. Acta 1985, 30, 683–694. [Google Scholar] [CrossRef] [Scilit]
  239. Vogt, H. Superposition of Microconvective and Macroconvective Mass Transfer at Gas-Evolving Electrodes—A Theoretical Attempt. Electrochim. Acta 1987, 32, 633–636. [Google Scholar] [CrossRef] [Scilit]
  240. Albuquerque, I.L.T.; Cavalcanti, E.B.; Vilar, E.O. Mass Transfer Study of Electrochemical Processes with Gas Production. Chem. Eng. Process. Process Intensif. 2009, 48, 1432–1436. [Google Scholar] [CrossRef] [Scilit]
  241. Vogt, H.; Stephan, K. Local Microprocesses at Gas-Evolving Electrodes and Their Influence on Mass Transfer. Electrochim. Acta 2015, 155, 348–356. [Google Scholar] [CrossRef] [Scilit]
  242. Zhou, H.; Chen, B.; Meng, K.; Chen, W.; Li, G.; Tu, Z. Experimental Investigation of Degradation Mechanism in Proton Exchange Membrane Water Electrolyzer under Prolonged and Severe Bubble Accumulation Condition. Chem. Eng. J. 2024, 491, 152202. [Google Scholar] [CrossRef] [Scilit]
  243. Maier, M.; Dodwell, J.; Ziesche, R.; Tan, C.; Heenan, T.; Majasan, J.; Kardjilov, N.; Markötter, H.; Manke, I.; Castanheira, L.; et al. Mass Transport in Polymer Electrolyte Membrane Water Electrolyser Liquid-Gas Diffusion Layers: A Combined Neutron Imaging and X-Ray Computed Tomography Study. J. Power Sources 2020, 455, 227968. [Google Scholar] [CrossRef] [Scilit]
  244. Wu, L.; An, L.; Jiao, D.; Xu, Y.; Zhang, G.; Jiao, K. Enhanced Oxygen Discharge with Structured Mesh Channel in Proton Exchange Membrane Electrolysis Cell. Appl. Energy 2022, 323, 119651. [Google Scholar] [CrossRef] [Scilit]
  245. Wu, L.; Pan, Z.; Yuan, S.; Shi, X.; Liu, Y.; Liu, F.; Yan, X.; An, L. A Dual-Layer Flow Field Design Capable of Enhancing Bubble Self-Pumping and Its Application in Water Electrolyzer. Chem. Eng. J. 2024, 488, 151000. [Google Scholar] [CrossRef] [Scilit]
  246. Shi, T.; Feng, H.; Liu, D.; Zhang, Y.; Li, Q. High-Performance Microfluidic Electrochemical Reactor for Efficient Hydrogen Evolution. Appl. Energy 2022, 325, 119887. [Google Scholar] [CrossRef] [Scilit]
  247. Ji, Y.; Wang, S.; Yao, S.; Ji, K.; Wu, J.; Bai, W.; Wang, G.; Yang, J.; Wang, J.; Zhang, F.; et al. Spatial-Confinement-Driven Bubble Self-Management for Compact, High-Performance Water Electrolyzers. Nano Lett. 2025, 25, 12025–12034. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  248. Hodges, A.; Hoang, A.L.; Tsekouras, G.; Wagner, K.; Lee, C.-Y.; Swiegers, G.F.; Wallace, G.G. A High-Performance Capillary-Fed Electrolysis Cell Promises More Cost-Competitive Renewable Hydrogen. Nat. Commun. 2022, 13, 1304. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  249. Bakker, M.M.; Vermaas, D.A. Gas Bubble Removal in Alkaline Water Electrolysis with Utilization of Pressure Swings. Electrochim. Acta 2019, 319, 148–157. [Google Scholar] [CrossRef] [Scilit]
  250. Bleeker, J.; Van Kasteren, C.; Van Ommen, J.R.; Vermaas, D.A. Gas Bubble Removal from a Zero-Gap Alkaline Electrolyser with a Pressure Swing and Why Foam Electrodes Might Not Be Suitable at High Current Densities. Int. J. Hydrogen Energy 2024, 57, 1398–1407. [Google Scholar] [CrossRef] [Scilit]
  251. Rocha, F.; Proost, J. Discriminating between the Effect of Pulse Width and Duty Cycle on the Hydrogen Generation Performance of 3-D Electrodes during Pulsed Water Electrolysis. Int. J. Hydrogen Energy 2021, 46, 28925–28935. [Google Scholar] [CrossRef] [Scilit]
  252. Demir, N.; Kaya, M.F.; Albawabiji, M.S. Effect of pulse potential on alkaline water electrolysis performance. Int. J. Hydrogen Energy 2018, 43, 17013–17020. [Google Scholar] [CrossRef] [Scilit]
  253. Khosla, N.K.; Venkatachalam, S.; Somasundaran, P. Pulsed Electrogeneration of Bubbles for Electroflotation. J. Appl. Electrochem. 1991, 21, 986–990. [Google Scholar] [CrossRef] [Scilit]
  254. Park, S.; Lohse, D.; Krug, D.; Koper, M.T.M. Electrolyte Design for the Manipulation of Gas Bubble Detachment during Hydrogen Evolution Reaction. Electrochim. Acta 2024, 485, 144084. [Google Scholar] [CrossRef] [Scilit]
  255. Hosseini, S.R.; Ghasemi, S.; Ghasemi, S.A. Effect of Surfactants on Electrocatalytic Performance of Copper Nanoparticles for Hydrogen Evolution Reaction. J. Mol. Liq. 2016, 222, 1068–1075. [Google Scholar] [CrossRef] [Scilit]
  256. Xie, Q.; Zhou, D.; Li, P.; Cai, Z.; Xie, T.; Gao, T.; Chen, R.; Kuang, Y.; Sun, X. Enhancing Oxygen Evolution Reaction by Cationic Surfactants. Nano Res. 2019, 12, 2302–2306. [Google Scholar] [CrossRef] [Scilit]
  257. Yang, S.; Yuan, J.; Xie, P.; Li, B.; Li, M.; Zhou, D.; Luo, L.; Sun, X. Macroscopic Bubble Generation Promoted by Nanobubble Seeds as a Traceless Anti-Fluctuation Strategy for Water Splitting. Nat. Commun. 2025, 16, 5732. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  258. Li, Y.; Zhang, H.; Xu, T.; Lu, Z.; Wu, X.; Wan, P.; Sun, X.; Jiang, L. Under-Water Superaerophobic Pine-Shaped Pt Nanoarray Electrode for Ultrahigh-Performance Hydrogen Evolution. Adv. Funct. Mater. 2015, 25, 1737–1744. [Google Scholar] [CrossRef] [Scilit]
  259. Ren, Q.; Feng, L.; Ye, C.; Xue, X.; Lin, D.; Eisenberg, S.; Kou, T.; Duoss, E.B.; Zhu, C.; Li, Y. Nanocone-Modified Surface Facilitates Gas Bubble Detachment for High-Rate Alkaline Water Splitting. Adv. Energy Mater. 2023, 13, 2302073. [Google Scholar] [CrossRef] [Scilit]
  260. Zhang, C.; Xu, Z.; Han, N.; Tian, Y.; Kallio, T.; Yu, C.; Jiang, L. Superaerophilic/Superaerophobic Cooperative Electrode for Efficient Hydrogen Evolution Reaction via Enhanced Mass Transfer. Sci. Adv. 2023, 9, eadd6978. [Google Scholar] [CrossRef] [Scilit]
  261. Liang, J.; Cai, Z.; Li, Z.; Yao, Y.; Luo, Y.; Sun, S.; Zheng, D.; Liu, Q.; Sun, X.; Tang, B. Efficient Bubble/Precipitate Traffic Enables Stable Seawater Reduction Electrocatalysis at Industrial-Level Current Densities. Nat. Commun. 2024, 15, 2950. [Google Scholar] [CrossRef] [Scilit]
  262. Sheng, S.; Shi, B.; Wang, C.; Luo, L.; Lin, X.; Li, P.; Chen, F.; Shang, Z.; Meng, H.; Kuang, Y.; et al. Antibuoyancy and Unidirectional Gas Evolution by Janus Electrodes with Asymmetric Wettability. ACS Appl. Mater. Interfaces 2020, 12, 23627–23634. [Google Scholar] [CrossRef] [Scilit]
  263. Habudula, G.; Zhang, X.; Kang, T.; Sun, G.; Liu, J.; Yu, H. Analysis of the Surface Wettability Regulation of Porous Transport Layers in Proton Exchange Membrane Electrolyzers Using the Polydimethylsiloxane Mask Modification Method. Int. J. Hydrogen Energy 2025, 100, 1201–1209. [Google Scholar] [CrossRef] [Scilit]
  264. Kang, Y.; Lee, S.; Lee, J.; Lee, S.; Lee, G.; Kim, H.; Choi, G.H.; Ryu, J.; Lee, D.W. Anisotropically Wettable Porous Transport Layers for Gas Management in Water Electrolyzers. Adv. Sci. 2026, 13, e08569. [Google Scholar] [CrossRef] [Scilit]
  265. Kang, J.; Liu, G.; Hu, Q.; Huang, Y.; Liu, L.-M.; Dong, L.; Teobaldi, G.; Guo, L. Parallel Nanosheet Arrays for Industrial Oxygen Production. J. Am. Chem. Soc. 2023, 145, 25143–25149. [Google Scholar] [CrossRef] [Scilit]
  266. Peng, Q.; Xu, H.; He, Y.; Jiang, Y.; Wu, Z.; Zhang, Y.; Zhu, X.; Li, J.; Yang, W.; Liao, Q. Aligned-Pore Engineering: Decoupling Gas-Liquid Transport in Gas Diffusion Electrodes. Joule 2025, 9, 102199. [Google Scholar] [CrossRef] [Scilit]
  267. Lee, J.K.; Lee, C.; Fahy, K.F.; Kim, P.J.; LaManna, J.M.; Baltic, E.; Jacobson, D.L.; Hussey, D.S.; Stiber, S.; Gago, A.S.; et al. Spatially Graded Porous Transport Layers for Gas Evolving Electrochemical Energy Conversion: High Performance Polymer Electrolyte Membrane Electrolyzers. Energy Convers. Manag. 2020, 226, 113545. [Google Scholar] [CrossRef] [Scilit]
  268. Yang, Y.; Li, J.; Yang, Y.; Lan, L.; Liu, R.; Fu, Q.; Zhang, L.; Liao, Q.; Zhu, X. Gradient Porous Electrode-Inducing Bubble Splitting for Highly Efficient Hydrogen Evolution. Appl. Energy 2022, 307, 118278. [Google Scholar] [CrossRef] [Scilit]
  269. Lin, M.-Y.; Hourng, L.-W.; Kuo, C.-W. The Effect of Magnetic Force on Hydrogen Production Efficiency in Water Electrolysis. Int. J. Hydrogen Energy 2012, 37, 1311–1320. [Google Scholar] [CrossRef] [Scilit]
  270. Baczyzmalski, D.; Karnbach, F.; Mutschke, G.; Yang, X.; Eckert, K.; Uhlemann, M.; Cierpka, C. Growth and Detachment of Single Hydrogen Bubbles in a Magnetohydrodynamic Shear Flow. Phys. Rev. Fluids 2017, 2, 93701. [Google Scholar] [CrossRef] [Scilit]
  271. Wang, K.; Liao, C.; Wang, W.; Xiao, Y.; Liu, X.; Zuo, Y. Removal of Gas Bubbles on an Electrode Using a Magnet. ACS Appl. Energy Mater. 2020, 3, 6752–6757. [Google Scholar] [CrossRef] [Scilit]
  272. Niether, C.; Faure, S.; Bordet, A.; Deseure, J.; Chatenet, M.; Carrey, J.; Chaudret, B.; Rouet, A. Improved Water Electrolysis Using Magnetic Heating of FeC–Ni Core–Shell Nanoparticles. Nat. Energy 2018, 3, 476–483. [Google Scholar] [CrossRef] [Scilit]
  273. Hung, C.-Y.; Li, S.-D.; Wang, C.-C.; Chen, C.-Y. Influences of a Bipolar Membrane and an Ultrasonic Field on Alkaline Water Electrolysis. J. Membr. Sci. 2012, 389, 197–204. [Google Scholar] [CrossRef] [Scilit]
  274. Cho, K.M.; Deshmukh, P.R.; Shin, W.G. Hydrodynamic Behavior of Bubbles at Gas-Evolving Electrode in Ultrasonic Field during Water Electrolysis. Ultrason. Sonochem. 2021, 80, 105796. [Google Scholar] [CrossRef] [Scilit]
  275. Walton, D.J.; Burke, L.D.; Murphy, M.M. Sonoelectrochemistry: Chlorine, Hydrogen and Oxygen Evolution at Platinised Platinum. Electrochim. Acta 1996, 41, 2747–2751. [Google Scholar] [CrossRef] [Scilit]
  276. Cheng, H.; Scott, K. An Empirical Model Approach to Gas Evolution Reactions in a Centrifugal Field. J. Electroanal. Chem. 2003, 544, 75–85. [Google Scholar] [CrossRef] [Scilit]
  277. Wang, M.; Wang, Z.; Guo, Z. Water Electrolysis Enhanced by Super Gravity Field for Hydrogen Production. Int. J. Hydrogen Energy 2010, 35, 3198–3205. [Google Scholar] [CrossRef] [Scilit]
  278. Sangtam, B.T.; Park, H. Review on Bubble Dynamics in Proton Exchange Membrane Water Electrolysis: Towards Optimal Green Hydrogen Yield. Micromachines 2023, 14, 2234. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  279. Wang, J.; Wang, H.; Xiong, J. Experimental Investigation on Microlayer Behavior and Bubble Growth Based on Laser Interferometric Method. Front. Energy Res. 2023, 11, 1130459. [Google Scholar] [CrossRef] [Scilit]
  280. Wang, W.; Xie, Z.; Li, K.; Yu, S.; Ding, L.; Zhang, F.-Y. Recent Progress in in-Situ Visualization of Electrochemical Reactions in Electrochemical Energy Devices. Curr. Opin. Electrochem. 2022, 35, 101088. [Google Scholar] [CrossRef] [Scilit]
  281. Qiu, H.; Obata, K.; Yuan, Z.; Nishimoto, T.; Lee, Y.; Nagato, K.; Kinefuchi, I.; Shiomi, J.; Takanabe, K. Quantitative Description of Bubble Formation in Response to Electrolyte Engineering. Langmuir 2023, 39, 4993–5001. [Google Scholar] [CrossRef] [Scilit]
  282. Toyama, K.; Kanemoto, R.; Misumi, R.; Araki, T.; Mitsushima, S. Faster R-CNN-Based Detection and Tracking of Hydrogen and Oxygen Bubbles in Alkaline Water Electrolysis. Electrochemistry 2025, 93, 027011. [Google Scholar] [CrossRef] [Scilit]
  283. Peng, C.; Liu, Y.; Gui, W.; Tang, Z.; Chen, Q. Bubble Image Segmentation Based on a Novel Watershed Algorithm with an Optimized Mark and Edge Constraint. IEEE Trans. Instrum. Meas. 2022, 71, 5005110. [Google Scholar] [CrossRef] [Scilit]
  284. Matthews, S.A.; Coelho, C.; Salas, E.E.R.; Brock, E.E.; Hodge, V.J.; Walker, J.A.; Wilson, L.G. Real-Time 3D Tracking of Swimming Microbes Using Digital Holographic Microscopy and Deep Learning. PLoS ONE 2024, 19, e0301182. [Google Scholar] [CrossRef] [Scilit]
  285. Huiping Liu, H.L.; Jia Yu, J.Y.; Tian Wang, T.W.; Yu Yang, Y.Y.; Jincheng Wang, J.W.; Ronger Zheng, R.Z. Digital Holography Experiment of 3D Detection of Underwater Bubble Fields. Chin. Opt. Lett. 2013, 11, S20901–S20903. [Google Scholar] [CrossRef] [Scilit]
  286. Shen, Z.-X.; Gao, M.; Dong, W.; Zhang, L. Experimental Investigation of the Microlayer and Dry Spot Dynamic Characteristics in a Small Channel Flow Boiling by Laser Interferometry Method. Int. J. Heat Mass Transf. 2023, 201, 123585. [Google Scholar] [CrossRef] [Scilit]
  287. Shao, S.; Hong, J. Measurement of 3D Bubble Distribution Using Digital Inline Holography. Chem. Eng. Sci. 2019, 207, 929–941. [Google Scholar] [CrossRef] [Scilit]
  288. Tian, L.; Loomis, N.; Domínguez-Caballero, J.A.; Barbastathis, G. Quantitative Measurement of Size and Three-Dimensional Position of Fast-Moving Bubbles in Air-Water Mixture Flows Using Digital Holography. Appl. Opt. 2010, 49, 1549–1554. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  289. Serizawa, A.; Kataoka, I.; Michiyoshi, I. Turbulence Structure of Air-Water Bubbly Flow—II. Local Properties. Int. J. Multiph. Flow 1975, 2, 235–246. [Google Scholar] [CrossRef] [Scilit]
  290. Wang, S.K.; Lee, S.J.; Jones, O.C.; Lahey, R.T. 3-D Turbulence Structure and Phase Distribution Measurements in Bubbly Two-Phase Flows. Int. J. Multiph. Flow 1987, 13, 327–343. [Google Scholar] [CrossRef] [Scilit]
  291. Zhang, L.; Cheng, X.; Tu, H.; Gao, Q.; Shao, X.; Liao, X.-W.; Zhao, L. Measurement of Two-Phase Velocities in Bubble Flows Using Laser Doppler Velocimetry. J. Hydrodyn. 2022, 34, 1134–1144. [Google Scholar] [CrossRef] [Scilit]
  292. Wu, Y.; Zhang, H.; Wu, X.; Cen, K. Quantifying Bubble Size and 3D Velocity in a Vortex with Digital Holographic Particle Tracking Velocimetry (DHPTV). Flow Meas. Instrum. 2020, 76, 101826. [Google Scholar] [CrossRef] [Scilit]
  293. Babich, A.; Bashkatov, A.; Yang, X.; Mutschke, G.; Eckert, K. In-Situ Measurements of Temperature Field and Marangoni Convection at Hydrogen Bubbles Using Schlieren and PTV Techniques. Int. J. Heat Mass Transf. 2023, 215, 124466. [Google Scholar] [CrossRef] [Scilit]
  294. Wang, W.; Yu, S.; Li, K.; Ding, L.; Xie, Z.; Li, Y.; Yang, G.; Cullen, D.A.; Yu, H.; Kang, Z.; et al. Insights into the Rapid Two-Phase Transport Dynamics in Different Structured Porous Transport Layers of Water Electrolyzers through High-Speed Visualization. J. Power Sources 2021, 516, 230641. [Google Scholar] [CrossRef] [Scilit]
  295. Yuan, S.; Zhao, C.; Fu, C.; Li, J.; Su, Y.; Xue, R.; Shen, S.; Yin, J.; Yan, X.; Zhang, J. Discovery of Bubble Accumulation Behavior in Catalyst Layer of Proton Exchange Membrane Water Electrolyzer. Int. J. Heat Mass Transf. 2024, 227, 125552. [Google Scholar] [CrossRef] [Scilit]
  296. Hoeh, M.A.; Arlt, T.; Kardjilov, N.; Manke, I.; Banhart, J.; Fritz, D.L.; Ehlert, J.; Lüke, W.; Lehnert, W. In-Operando Neutron Radiography Studies of Polymer Electrolyte Membrane Water Electrolyzers. ECS Trans. 2015, 69, 1135. [Google Scholar] [CrossRef] [Scilit]
  297. Seweryn, J.; Biesdorf, J.; Schmidt, T.J.; Boillat, P. Communication—Neutron Radiography of the Water/Gas Distribution in the Porous Layers of an Operating Electrolyser. J. Electrochem. Soc. 2016, 163, F3009–F3011. [Google Scholar] [CrossRef] [Scilit]
  298. Selamet, O.F.; Pasaogullari, U.; Spernjak, D.; Hussey, D.S.; Jacobson, D.L.; Mat, M.D. Two-Phase Flow in a Proton Exchange Membrane Electrolyzer Visualized in Situ by Simultaneous Neutron Radiography and Optical Imaging. Int. J. Hydrogen Energy 2013, 38, 5823–5835. [Google Scholar] [CrossRef] [Scilit]
  299. Panchenko, O.; Borgardt, E.; Zwaygardt, W.; Hackemüller, F.J.; Bram, M.; Kardjilov, N.; Arlt, T.; Manke, I.; Müller, M.; Stolten, D.; et al. In-Situ Two-Phase Flow Investigation of Different Porous Transport Layer for a Polymer Electrolyte Membrane (PEM) Electrolyzer with Neutron Spectroscopy. J. Power Sources 2018, 390, 108–115. [Google Scholar] [CrossRef] [Scilit]
  300. Parra-Restrepo, J.; Bligny, R.; Dillet, J.; Didierjean, S.; Stemmelen, D.; Moyne, C.; Degiovanni, A.; Maranzana, G. Influence of the Porous Transport Layer Properties on the Mass and Charge Transfer in a Segmented PEM Electrolyzer. Int. J. Hydrogen Energy 2020, 45, 8094–8106. [Google Scholar] [CrossRef] [Scilit]
  301. Maier, M.; Meyer, Q.; Majasan, J.; Tan, C.; Dedigama, I.; Robinson, J.; Dodwell, J.; Wu, Y.; Castanheira, L.; Hinds, G.; et al. Operando Flow Regime Diagnosis Using Acoustic Emission in a Polymer Electrolyte Membrane Water Electrolyser. J. Power Sources 2019, 424, 138–149. [Google Scholar] [CrossRef] [Scilit]
  302. Maier, M.; Owen, R.E.; Pham, M.T.M.; Dodwell, J.; Majasan, J.; Robinson, J.B.; Hinds, G.; Shearing, P.R.; Brett, D.J.L. Acoustic Time-of-Flight Imaging of Polymer Electrolyte Membrane Water Electrolysers to Probe Internal Structure and Flow Characteristics. Int. J. Hydrogen Energy 2021, 46, 11523–11535. [Google Scholar] [CrossRef] [Scilit]
  303. Carmona-Hernández, A.; Orozco-Cruz, R.; Carpio-Santamaria, F.A.; Campechano-Lira, C.; López-Huerta, F.; Mejía-Sánchez, E.; Contreras, A.; Galván-Martínez, R. Electrochemical Noise Analysis of the X70 Pipeline Steel under Stress Conditions Using Symmetrical and Asymmetrical Electrode Systems. Metals 2022, 12, 1545. [Google Scholar] [CrossRef] [Scilit]
  304. Jáquez-Muñoz, J.M.; Gaona-Tiburcio, C.; Méndez-Ramírez, C.T.; Martínez-Ramos, C.; Baltazar-Zamora, M.A.; Santiago-Hurtado, G.; Estupinan-Lopez, F.; Landa-Ruiz, L.; Nieves-Mendoza, D.; Almeraya-Calderon, F. Electrochemical Noise Analysis: An Approach to the Effectivity of Each Method in Different Materials. Materials 2024, 17, 4013. [Google Scholar] [CrossRef] [Scilit]
  305. German, S.R.; Chen, Q.; Edwards, M.A.; White, H.S. Electrochemical Measurement of Hydrogen and Nitrogen Nanobubble Lifetimes at Pt Nanoelectrodes. J. Electrochem. Soc. 2016, 163, H3160. [Google Scholar] [CrossRef] [Scilit]
  306. Dastafkan, K.; Wang, S.; Song, S.; Meyer, Q.; Zhang, Q.; Shen, Y.; Zhao, C. Operando Monitoring of Gas Bubble Evolution in Water Electrolysis by Single High-Frequency Impedance. EES Catal. 2023, 1, 998–1008. [Google Scholar] [CrossRef] [Scilit]
  307. Dedigama, I.; Angeli, P.; Ayers, K.; Robinson, J.B.; Shearing, P.R.; Tsaoulidis, D.; Brett, D.J.L. In Situ Diagnostic Techniques for Characterisation of Polymer Electrolyte Membrane Water Electrolysers—Flow Visualisation and Electrochemical Impedance Spectroscopy. Int. J. Hydrogen Energy 2014, 39, 4468–4482. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.