Abstract
Energy and exergy analyses of a geothermal-driven Organic Rankine Cycle (ORC) utilizing alternative organic mixtures with low global warming potential (GWP) as working fluids were conducted. New mixtures were created in REFPROP 10 using organic fluids commonly employed in fluid analysis. Among the 108 newly formulated organic working fluid mixtures, 12 candidates characterized by a temperature glide of less than 5 °C, a high critical temperature, and a GWP value below 750 were selected for this study. Energy and exergy assessments were performed for power generation using the selected fluids at geothermal brine temperatures of 130–150 °C (in 5 °C increments) and a condenser temperature of 30 °C. Additionally, the cycle’s net power output ( net), thermal efficiency (ηth) and second-law efficiency (ηıı) were quantified. Based on the simultaneous maximization of net, ηth and ηıı specific fluid recommendations are proposed: b7 is optimal for low-temperature, ultra-low-GWP geothermal and waste heat conversation (GWP < 150, TCR < 165 °C); b1 is recommended for high-enthalpy geothermal applications requiring low environmental impact (GWP < 150, TCR > 165 °C); and b9 serves as the prime candidate for medium-GWP (150 < GWP < 750) commercial power plants aiming for maximum energy conversation. Among all evaluated working fluids, b7 (GWP < 150) achieved the maximum net, ηth and ηii, proving to be the most promising organic blend owing to its favorable thermophysical properties and ultra-low GWP.