Skip to Content
EnergiesEnergies
  • Article
  • Open Access

16 November 2026

26 Pages

Simulation-Based Parametric Sensitivity Analysis of a Natural Gas Combined-Cycle Plant with Amine-Based Post-Combustion CO2 Capture

,
,
,
,
,
,
and
1
Department of Mechanical Engineering, Faculty of Mechanical and Aeronautical Engineering, University of Engineering and Technology (UET), Taxila 47080, Pakistan
2
Department of Mechanical Engineering, Universiti Teknologi PETRONAS, Bandar Seri Iskandar 32610, Perak, Darul Ridzuan, Malaysia
3
Department of Thermal Science and Energy Engineering, University of Science and Technology of China, Hefei 230027, China
4
State Key Laboratory of Subtropical Building and Urban Science, South China University of Technology, Guangzhou 510641, China

Abstract

Integrating post-combustion CO2 capture (PCC) with natural gas combined-cycle (NGCC) power generation requires consideration of both power-cycle performance and capture-process requirements. This study develops an Aspen HYSYS model comprising two gas turbines, a heat recovery steam generator (HRSG), a steam turbine, and an amine-based CO2 absorption–regeneration system. A one-variable-at-a-time sensitivity analysis examines the effects of compressor-stream temperature, pressure, and mass flow rate on individual turbine power outputs. Separate capture-process scans examine solvent circulation rate, absorber configuration and temperature, and regeneration conditions. These simulations identify individual parameter sensitivities but do not quantify interactions among the varied inputs or establish optimal plant operating conditions. Increasing the process-stream temperature from 100 to 500 °C raises the combined turbine outputs by 29.60 MW, while an analytical first-law assessment estimates an additional sensible-heating requirement of approximately 1206.0 MW using an air-equivalent specific heat approximation. These findings highlight the importance of accounting for thermal-energy requirements when evaluating turbine performance and overall plant efficiency. Increasing the mass flow rate from 500 to 5000 kg/s increases the first gas turbine output from 74.35 to 742.2 MW. A plant-wide assessment further accounts for auxiliary electrical consumption, steam extraction for solvent regeneration, and CO2 compression requirements. The calculated net electrical output decreases from 547.73 MW without PCC to 465.74 MW with PCC, corresponding to a reduction in net thermal efficiency from 44.80% to 38.10%. At a CO2 capture fraction of 90% and a specific reboiler duty of 3.80 GJ/t CO2, direct CO2 emissions intensity decreases from 459.44 to 54.03 kg CO2/MWh. The results identify key operating parameters influencing power generation and CO2 capture performance. The imposed temperature range is intended for model sensitivity analysis rather than representing practical compressor-inlet conditions. These findings highlight the trade-off between CO2 emissions reduction and the associated energy penalty in the integrated NGCC–PCC system.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.