Parametric Thermo-Hydraulic Benchmarking of Capsule and Dimple Plate Heat Exchanger Channels via Periodic Unit-Cell CFD

,
,
,
,
,
and
1
School of Engineering, RMIT University, Melbourne, VIC 3000, Australia
2
InKorr Pty Ltd., Knoxfield, VIC 3180, Australia
*
Author to whom correspondence should be addressed.
This article belongs to the Section J: Thermal Management

Abstract

Direct comparisons between capsule- and dimple-embossed plate heat exchanger channels are limited by differences in operating conditions and metric definitions across published studies. This study addresses that comparison gap through a side-by-side assessment under a common steady-state, single-phase water-flow Reynolds-averaged Navier–Stokes framework, unit-cell approach, thermal boundary conditions and reporting definitions at Re = 4282. Four seven-case sweeps vary capsule angle, capsule height, dimple height and dimple flow-entry angle; one additional case combines the largest tested dimple height and angle. The unit cells use lateral periodic boundaries and a streamwise quasi-periodic iteration loop for velocity and turbulence profiles, while inlet temperature remains prescribed. The performance evaluation criterion (PEC) combines the two-wall Nusselt number with the Fanning friction factor to quantify the heat-transfer–flow-resistance trade-off. The heat-transfer coefficient uses both walls’ total heat rate and area, referenced to each case’s fluid-domain mass-average static temperature. Relative embossing depth (RED) is height divided by the case-specific hydraulic diameter. Constructed PEC ranges are 254.6–273.0 for capsule angle, 254.8–294.6 for capsule height, 234.0–285.2 for dimple angle and 214.8–251.0 for dimple height. The combined dimple case gives PEC = 305.14, compared with 294.64 for the 5 mm capsule case. Their 3.56% separation is not an uncertainty-resolved performance advantage. These are comparative outcomes within the tested parameter ranges and unit-cell heating conditions.

1. Introduction

Plate heat exchangers (PHEs) place a large heat-transfer area within a compact volume and are widely used in power generation, process industries, heating and cooling systems, and refrigeration. Alternating embossed plates form narrow passages that repeatedly disturb the thermal and hydrodynamic boundary layers. This disturbance can strengthen convection and reduce the area required for a specified thermal duty, but the associated separation, recirculation, and wall shear also increase pressure loss and pumping demand. Heat transfer and hydraulic resistance are therefore coupled design objectives: an embossing should not be judged by Nusselt number alone if its thermal gain is obtained at a disproportionate friction penalty [1,2,3]. Although chevron plates remain the conventional reference, capsule, dimple, and pillow surfaces provide alternative ways to control the flow path and surface-area distribution.
The capsule studies summarized in Table 1 demonstrate that performance depends on more than the presence of an embossing. Hamedi et al. [4] reported that a symmetric convex–concave capsule arrangement increased the Nusselt number by 28–55% relative to a simple channel, but also increased the friction factor by 35–44%. Capsule aspect ratio and size further shift this balance: a larger length-to-width ratio can improve energy efficiency, whereas smaller capsules intensify heat transfer and pressure loss [5,6]. Symmetric arrangements have outperformed zig-zag layouts, and capsule surfaces have also produced higher Nusselt numbers with lower friction factors than chevron surfaces under the conditions examined by Zhang et al. [7]. Geometry optimization produced an 8.3% increase in heat-transfer coefficient together with a 14.3% reduction in friction [8], while adding secondary dimples to capsule surfaces increased heat transfer by 19–46% [9]. Collectively, these results show that capsule orientation, size, aspect ratio, and arrangement can reorganize the thermal–hydraulic trade-off; they do not identify one configuration that remains superior under a different geometry or operating basis.
The dimple and pillow literature shows the same sensitivity to geometry. Pillow plates have required 30% less heat-transfer area than chevron plates while producing a lower pressure drop [10], and a dimpled pillow channel achieved an 11.2% thermo-hydraulic improvement with an 8.7% pressure-loss reduction [11]. For standalone dimple surfaces, Soman et al. [12] reported a 39% Nusselt-number increase relative to a flat PHE, while hemispherical dimples produced a heat-transfer coefficient approximately 27.2% higher than rhombus dimples [13]. Numerical predictions have also been compared with experiments for several dimple channels, including deviations of − 11 % to 1.8% in one study series [14,15,16]. Other investigations considered supercritical CO2, nanofluids, lubricating oil, two-phase flow, or hybrid capsule–dimple plates [9,17,18,19,20]. These results confirm that dimple shape, channel configuration, and working fluid all influence the balance between heat transfer and pressure loss.
Table 1 thus provides strong evidence for both embossing families, but it also exposes the comparison gap. The reported studies use different fluids, Reynolds-number ranges, channel domains, boundary conditions, hydraulic-diameter definitions, turbulence models, reference surfaces, and performance measures. Some investigate single-phase water, whereas others consider nanofluids, supercritical fluids, or multiphase flow; some report Nusselt number and friction factor separately, whereas others use a combined thermo-hydraulic index. Consequently, the published percentage improvements cannot be ranked on a common scale. Most studies also vary parameters within one surface family, leaving it unclear whether the performance of CPHE and DPHE channels responds similarly when angle and height are changed over comparable ranges.
A controlled computational fluid dynamics (CFD) study is suitable for resolving this gap because it provides both integral performance measures and spatial evidence of the mechanisms that produce them. Nusselt number and pressure loss quantify the overall thermal and hydraulic response, while turbulence kinetic energy, streamlines, and temperature fields reveal how an embossing redirects flow, forms wakes, and transports heat from the wall to the channel core. Periodic unit cells have been used successfully for repeating capsule and dimple geometries because they retain the local embossing-induced mechanisms while avoiding the cost of modeling an entire exchanger [4,5,6,9,11]. Published comparisons with experiments also support the use of steady RANS modeling for this class of channel [14,15,16]. The SST k– ω model is selected because its near-wall treatment and response to adverse pressure gradients are suited to the separated flows produced by embossed passages [21,22].
Table 1. Summary of embossing surface enhancement of PHEs.
The present study therefore benchmarks capsule-type plate heat exchanger (CPHE) and dimple-type plate heat exchanger (DPHE) channels within one steady-state, single-phase water-flow RANS framework at Re = 4282 . Both geometries use a periodic unit cell, common thermal and hydraulic boundary conditions, and the same hydraulic-diameter definition, so the effects of geometry are not obscured by a change in the numerical basis. Twenty-eight one-factor cases comprise four seven-case sweeps. Capsule and dimple angles cover 0 ° – 45 ° in 7.5 ° increments, while capsule and dimple heights cover 2.0–5.0 mm in 0.5 mm increments; the remaining geometric variables are held at the reference values listed in Section 2.2.3. This design separates the effects of capsule angle ( θ c ), capsule height ( h c ), dimple height ( h d ), and dimple flow-entry angle ( θ d ). One additional case combines θ d = 45 ° with h d = 5.0  mm to test a targeted dimple interaction identified from the one-factor results, rather than treating the four sweeps as a full factorial optimization.
The study has three objectives: to quantify how the four geometric variables change Nusselt number and the friction factor; to explain those changes using the computed flow and temperature fields; and to compare CPHE and DPHE cases through the performance evaluation criterion (PEC) and relative embossing depth (RED). PEC expresses the heat-transfer–friction trade-off on a common scale, while RED relates embossing height to the effective channel size. This common framework permits a direct benchmark that the heterogeneous literature cannot provide. The finite sweeps and single combined case nevertheless support conclusions only for the tested geometry, fluid, Reynolds number, and boundary conditions; they do not establish a global optimum across untested parameter interactions.

2. Methodology

This numerical investigation applies a common computational fluid dynamics (CFD) framework to benchmark the thermo-hydraulic performance of CPHE and DPHE channels. The method combines periodic unit-cell representation, mesh-independence testing, literature-supported turbulence modeling, and controlled parametric sweeps [14,23]. The calculation sequence is case selection and geometric-domain construction, mesh generation with near-wall prism layers, physical-model and boundary-condition assignment, steady solution through the streamwise quasi-periodic iteration loop, and consistent reduction of the saved fields to thermal and hydraulic metrics. Section 2.2.3 and Scheme 1 distinguish the solver iterations within each period from the outlet-to-inlet profile-transfer loop between periods.
Scheme 1. Computational workflow and streamwise quasi-periodic iteration loop. Steady solver iterations are nested inside the reported profile-transfer sequence; the lateral periodic pair remains active throughout. Temperature is not transferred from outlet to inlet. Physical-output stability is assessed separately from the period count. The final batch-reduction stage refers to the post-processing of the saved solutions.

2.1. Numerical Methods

The Reynolds-averaged Navier–Stokes (RANS) approach is widely used in numerical studies of capsule and dimple channels. Published models include realizable k– ϵ  [14,16,17,26], shear stress transport (SST) k– ω [4,5,6,14,16,20], Reynolds stress [9,15], elliptic-blending k– ϵ [10,11], and standard k– ϵ [12]. The SST k– ω model is used here because it combines near-wall k– ω treatment with a k– ϵ formulation away from the wall and is suited to separated flows with adverse pressure gradients [21,22,28].
All simulations use steady-state, single-phase water flow at subcritical pressure and temperature.
The channel scale is defined using the adopted unit-cell hydraulic-diameter convention,
D e = 4 A 0 L S , S = S 1 + S 2 ,
where A 0 is the inlet flow area used in the saved cases, L = l c = l d = 25  mm is the inlet-to-outlet cell length, and S 1 and S 2 are the two wetted, heated wall areas. This is an effective passage-scale definition: replacing the wetted perimeter in the usual 4 A / P expression by S / L gives Equation (1) [2,29]. It should not be interpreted as a local hydraulic diameter at every cross-section of the embossed passage. Its numerical value is evaluated separately from each saved mesh.
The Reynolds number follows the standard definition [2,30],
Re = u D e υ , υ = μ ρ .
The prescribed reference speed is therefore u = 4282 μ / ( ρ D e ) . An equal Reynolds number does not imply equal speed when D e varies: the saved cases give u = 0.308 – 0.679  m/s. This is the reference mean speed used to scale the recycled velocity-component profiles, not an assumption of a uniform inlet profile or a substitution for the inlet-normal bulk velocity.
Fanning friction factor is adopted in this study, denoted f F (or simplified as f in the plots) [2,30].
f F = Δ p D e 2 ρ L u 2 .
Here, Δ p is the difference between the area-averaged static pressures at the inlet and outlet. Thus, the factor 2 in the denominator is intentional for the Fanning convention. All walls are stationary, no-slip and hydraulically smooth.
For constant C p and balanced inlet and outlet mass flow, the net fluid energy gain follows the steady-flow calorimetric balance [2,5],
Q f = m ˙ C p T f , o u t ( E ) − T f , i n ( E ) .
Here, b ∈ { i n , o u t } identifies the inlet or outlet boundary. For constant C p , the energy-balance temperature is the signed temperature flow rate divided by the net mass flow [31] (Section 25.3.1, Equations 25–16 and 25–17):
T f , b ( E ) = ∑ i ∈ b m ˙ i T i ∑ i ∈ b m ˙ i ,
where m ˙ i is the signed face mass flow rate relative to the boundary’s outward normal; the net boundary mass flow is nonzero. Where local backflow occurs, conservation is checked using signed enthalpy-flux integrals rather than substituting absolute-flux temperature averages into the calorimetric balance [31] (Section 25.1). The wall heat rate used below is obtained directly from both heated walls, independently of this diagnostic.
For the constructed Nu results and PEC comparisons in Section 3, the case-specific reporting reference is the mass-weighted volume average of static temperature over the entire fluid domain Ω f , as defined in [31] (Section 25.4.1, Equation 25–39):
T ref = T f , a v e = ∫ Ω f ρ T d V ∫ Ω f ρ d V = ∑ i ∈ Ω f ρ i V i T i ∑ i ∈ Ω f ρ i V i .
Here, V i , ρ i and T i are the volume, density and static temperature of fluid cell i. The integral is normalized by the total fluid mass, so T f , a v e has units of temperature. It weights the mass contained in each cell, not the mass flow crossing a boundary. For the constant-density water used here, it is identical to the volume-weighted average ∑ i V i T i / ∑ i V i . This fluid-domain average is distinct from the signed inlet and outlet temperatures T f , b ( E ) used in the energy balance; it is not their arithmetic mean or difference.
The average heat-transfer coefficient is obtained by area-weighted averaging of Fluent’s built-in Surface Heat Transfer Coef. over the union of wall_1 and wall_2, with the Reference Values temperature set to the case-specific T f , a v e . The equivalent value is constructed directly from the saved wall heat fluxes without modifying the original solution files. For the uniform wall temperature T w = 333  K, the Fluent field definition and surface-averaging procedure [32] give
h a v e = 1 S 1 + S 2 ∫ S 1 ∪ S 2 q ′ ′ T w − T ref d S = Q 1 + Q 2 ( S 1 + S 2 ) ( T w − T f , a v e ) , Q j = ∫ S j q ′ ′ d S .
Heat flux is positive from the heated walls into the water. Both wall heat rates and both wall areas therefore enter Equation (5); the individual wall coefficients are not added. This fluid-temperature-based form is consistent with the form of the mean coefficient in Jiang et al. [5], while the specific choice of a fluid-domain mass-average reference is defined explicitly here and is not attributed to that paper.
For θ c = 0 ° , the fluid-domain mass-average static temperature is T ref = T f , a v e = 296.1537  K, giving h a v e = 5346.87  W m−2 K−1. Across all 29 cases, T f , a v e ranges from 295.4045 to 296.7044 K; each case uses its own value. The physical inlet temperature is 293 K and both walls are prescribed at 333 K. The reporting reference does not impose an additional thermal boundary condition or change the solved temperature field, wall heat rates or flow field.
The Nusselt and molecular Prandtl numbers use the standard nondimensional definitions [2],
Nu = h a v e D e λ ,
Pr = μ C p λ = υ ρ C p λ ,
where λ is the fluid thermal conductivity. Every case uses the same two-wall averaging and fluid-temperature-reference convention, although the numerical value of T ref varies with the saved fluid temperatures. This postprocessing definition does not imply thermally periodic temperature profiles.

2.2. Geometry

Two embossed channel families are considered: capsule and dimple. Both use alternating convex and concave features to disturb the flow, but their planform geometry differs.
The periodic surface is represented by its smallest repeating unit cell. This commonly used approach reduces the computational domain while retaining the flow, thermal, and turbulence mechanisms generated by the repeating embossments [4,6,7,9,11,23,26].
The local cross-sectional wall profile is generated using the cosine function
y ( x ) = h 2 1 + cos 2 π x D , − D 2 < x < D 2 .
Here, h is the profile height and D is the full span of the local profile (the diameter for a dimple). The coordinate x is measured from the profile center, and y ( x ) is the displacement from the local reference plane. The profile reaches y ( 0 ) = h at its center and approaches zero at either edge. These are local profile coordinates, distinct from the global CFD coordinate directions.

2.2.1. CPHE

Figure 1 and Figure 2 show the CPHE channel formed between two capsule-embossed plates. Consecutive plates are inverted and rotated, so alternating concave and convex embossings form the spiral-like pattern of two concave and two convex capsules. The geometric parameters are capsule length (l), width (w), height ( h c ), unit-cell length ( l c ), angle ( θ c ), and center C, defined by the intersection of perpendicular lines through the capsule midpoints. The angle θ c is measured anticlockwise from the mainstream flow direction to the capsule major axis; at 0 ° , they are aligned. Higher angles rotate the capsule CAD anticlockwise while the flow-entry direction remains fixed normal to the inlet, with l, w, h c , and l c unchanged. Table 2 lists the initial dimensions.
Figure 1. Unit cell dimensions.
Figure 2. Schematics and unit cells for (a) a capsule-type plate heat exchanger (CPHE) and (b) a dimple-type plate heat exchanger (DPHE); blue and green labels in these panels denote concave and convex embossings. (c) Boundary map from the θ c 0° mesh. Blue and orange identify the lower and upper heated walls; water occupies the gap. The green inlet and purple outlet are distinguished from the lateral periodic pair. Colors identify regions, not temperature. The model contains no solid plate volume or separate exterior-air region.
Table 2. Dimensions of the initial geometry.

2.2.2. DPHE

Figure 2 shows the DPHE channel and unit cell formed by plates with opposing dimple embossings. The same unit-cell approach is used, with dimple height ( h d ), diameter (D), and unit-cell length ( l d ) as the main dimensions. Because each dimple is circular, the CAD geometry remains fixed during the angle sweep. The flow-entry angle θ d is measured from the fixed line joining adjacent dimple centers to the mainstream flow direction (Figure 1) and is varied by changing the direction from which flow enters the unchanged dimple array. Table 2 lists the initial dimensions.

2.2.3. Boundary Conditions and Computational Workflow

The lateral faces form a translational periodic pair. In the streamwise direction, an external quasi-periodic iteration loop transfers the outlet Cartesian velocity components, turbulent kinetic energy k and specific dissipation rate ω to the inlet for the next period; the inlet and outlet are not a built-in periodic boundary pair. One period comprises the steady solver iterations between successive profile transfers. The inlet temperature remains 293 K and no outlet temperature profile is imposed at the inlet. Both no-slip walls are held at 333 K. The pressure outlet has zero gauge pressure; its 293.7 K total-temperature setting applies only to fluid entering through that boundary during local backflow.
With constant fluid properties and no buoyancy coupling, the momentum and turbulence solution is independent of temperature. The streamwise loop therefore targets a repeatable hydrodynamic state, but neither the block count nor a stable heat-transfer integral establishes thermal periodicity. The thermal results are interpreted as unit-cell heating with quasi-periodic hydrodynamic profile transfer, not as a demonstrated thermally fully developed periodic solution. The workflow below describes the calculation structure.
Figure 2c locates the boundaries on an example computational domain, and Table 3 summarizes the recovered settings. The two walls are opposing wetted surfaces of one water passage, not the inner and outer faces of a meshed solid plate. The coefficient reporting reference is assigned as T ref = T f , a v e for each saved solution, as defined in Equation (5) and its accompanying fluid-domain mass-average temperature definition; it is not an additional imposed fluid boundary temperature.
Table 3. Boundary conditions, varied parameters and numerical settings recovered from the saved cases. Reporting quantities are distinguished from physical boundary conditions.
  • Calculation and Testing Sequence
Scheme 1 summarizes the following sequence for each parameter case.
1.
Construct the domain and mesh. Select the case from Table 4, varying only the nominated angle or height while retaining the companion parameters. Construct the capsule geometry, or retain the dimple array and change the flow-entry direction for its angle sweep. Generate the fluid-domain poly-hexacore mesh with near-wall prism layers and the mesh-quality controls in Section 2.3. Identify the inlet, outlet, two heated walls and lateral periodic pair. Evaluate A 0 , S 1 , S 2 and D e , then calculate the reference speed for Re = 4282 .
Table 4. Geometric parameter cases for CPHE and DPHE.
2.
Assign models and solve a period. Apply the constant water properties, energy equation, SST k– ω model, coupled pressure–velocity scheme and second-order discretization listed in Table 3. Starting from the current inlet data, iterate the steady equations and check the configured residual targets. Velocity, mass-flow, pressure-drop and thermal-report trends provide separate checks on physical-output stability; low residuals alone are insufficient.
3.
Transfer the outlet profiles. At the end of one period, export the outlet velocity components, k and ω , map them to the inlet, and apply the saved profile-scaling expressions before the next period. The velocity field is scaled to the reference mean speed and its in-plane direction is corrected to the prescribed flow-entry direction. The velocity scale factor is denoted as a, and the inlet velocity component u x , u y , u z , and ω will be scaled by a, while k will be scaled by a 2 . Keep T i n = 293 K and the wall temperatures unchanged. Compare available profile and integral-output records between periods to assess hydrodynamic repeatability.
4.
Reduce the final fields consistently. Batch post-processing extracts the mesh areas, area-averaged inlet/outlet pressures, separate wall heat rates and fluid-domain mass-average static temperature from the saved case/data pairs. The same expressions in Section 2.1 give D e , u, h a v e , Nu and f F ; Equations (9) and (10) give PEC and RED. Signed mass and enthalpy fluxes supply separate conservation checks. Store outputs by case label, retain the geometric and flow-direction identifiers, and compare the four sweeps and the targeted combined dimple case. This automated data-reduction step does not imply that the original geometry generation and solver loop were fully automated.

2.2.4. Geometric Parameters

A one-factor-at-a-time analysis is used to isolate the effects of capsule angle, capsule height, dimple height, and dimple flow-entry angle. Table 4 summarizes the four seven-case sweeps, the fixed variables in each sweep, and the targeted combined dimple case. The tested ranges follow prior studies and commercially available products [4,5,6,16,17,19,23,33]. The common physical models and case-specific residual targets are listed in Table 3. The recorded thermo-fluid outputs include Nu, f, Δ p , and turbulence kinetic energy fields.
After the one-factor sweeps, one interaction case combines θ d = 45 ° with h d = 5.0 mm. It is reported separately from the two seven-case dimple sweeps. The same physical models, discretization choices and post-processing definitions are applied across the parameter matrix; the case-specific hydraulic diameter and reference speed are recalculated rather than imposing one common velocity. The four sweeps and combined case give 29 case labels but 27 distinct saved solutions, because two reference solutions are shared between sweeps. The combined case is an angle–height combination within the dimple family, not a capsule–dimple hybrid surface or a full factorial search.

2.2.5. Performance Evaluation Criteria

The following performance metrics are used to compare the results:
  • Nusselt Number (Nu): Measures convective heat transfer relative to conduction across the fluid layer. A higher Nu indicates stronger convective heat transfer.
  • Friction Factor (f): Measures flow resistance from the simulated pressure loss, as defined by Equation (3).
  • Performance Evaluation Criterion (PEC): Combines heat transfer and flow resistance to rank all 29 cases on a common scale:
    PEC = Nu f F 1 / 3
    Thermal–hydraulic assessment combines heat-transfer and pressure-loss measures [2,4,6,23]. Equation (9) defines the unnormalized index adopted in this study: higher values indicate a higher two-wall, fluid-temperature-referenced Nu relative to the cube root of f F on the same comparison basis. It is not a baseline-normalized enhancement factor or, by itself, proof of superior exchanger performance at equal pumping power. Its use here requires the same coefficient, temperature-reference convention and friction convention for every plotted case. Section 3.1.1, Section 3.1.2, Section 3.2, Section 3.2.1 and Section 3.2.2 analyze trends in Nu and f individually; Section 3.3 uses PEC to rank all cases and compare both embossing families.
The comparison identifies heat-transfer and flow-resistance trade-offs among the examined cases. Because each primary sweep changes one geometric variable while the others remain fixed and only one targeted combined case is included, the results do not establish a global optimum across interacting variables or untested conditions.
  • Relative Embossing Depth (RED)
Embossing depth constrains plate spacing and channel size. Relative embossing depth (RED) is introduced to compare the protrusion height with the effective channel scale:
RED = h D e
where h is the embossing height ( h c or h d ) and D e is given by Equation (1), with both lengths expressed in the same units. RED is a dimensionless descriptor defined for the present comparison, not an externally fitted correlation. It varies with height and, for the capsule-angle cases, with the measured mesh-dependent D e . All dimple-angle cases share the same geometry and RED. Thus, RED alone does not identify a unique geometric or flow-entry-angle case, even within the dimple-angle family.

2.3. Mesh Independence

An unstructured poly-hexacore mesh type is adopted for the mesh generation. With guidance from the literature, certain criteria are set for the mesh generated to minimize discretizations and interpolation error [34,35], including mesh orthogonality and mesh skewness. For this study, the criteria of minimum mesh orthogonality of 0.1 and maximum mesh skewness of 0.8 are set for all cases. Representative CPHE and DPHE meshes are shown in Figure 3a,b.
Figure 3. Representative (a) CPHE and (b) DPHE meshes, and (c) CPHE mesh-sensitivity results.
To accurately predict the wall heat transfer coefficient and the wall shear stress close to the wall, prism layers are included in the mesh generation. Prism layers are hexahedral cells that are normal to the wall boundary to capture the steep normal gradient in the mean velocity and temperature inside the thermal and hydraulic boundary layers. The total prism layer thickness should capture the turbulent boundary layer of the flow. The initial estimation of the total boundary layer thickness δ can be estimated through the equation of δ / x = 0.16 / Re x 1 / 7 [30], where x is the total stream length, which is l c and l d for this study, and Re is the Reynolds number.
For the prism layers to accurately predict the near-wall behavior, the first prism layer thickness (or the first layer height) plays an important role in calculating the behavior at the viscous sub-layer, as it is related to y + , which is a dimensionless distance normal to the wall, and the near-wall kinematic viscosity can be calculated accordingly. To minimize the numerical uncertainty, y + < 1 should be applied for the SST k– ω turbulence model [36]; the first layer height is set to 0.0002 mm, with 7 boundary layers and transition ratio as 0.5, and the resultant y + is 0.087 (Figure 3a).
A mesh-sensitivity study was performed for CPHE with h = 2.5 mm, as shown in Figure 3c. f and Nu for five different meshes ranging from ∼100k to ∼1.1M elements are compared to determine the coarsest mesh. The difference in f and Nu between the results of ∼800k mesh count and ∼1.1M mesh count is less than 2.7% and 2%, respectively, and the ∼800k mesh was used.
  • DPHE Mesh-Sensitivity Assessment
A dedicated assessment was performed for a representative DPHE case using six meshes from 103k to 1622k cells (Table 5). The geometry, physical conditions and reporting basis were consistent across the meshes; iterative convergence, mesh consistency, direct velocity and fluid-temperature results, and near-wall resolution were verified before the comparison. Nu was evaluated using both heated walls and the fluid-domain mass-average reference temperature defined in Section 2.1. Nu increased with refinement, whereas the Fanning friction factor approached a stable value on the two finest meshes. Refining from 855k to 1622k cells changed Nu and f F by 2.20% and 0.095%, respectively, relative to the finest-mesh values.
Table 5. DPHE mesh-sensitivity results. The three finest meshes are used for the GCI assessment, with indices 1, 2 and 3 denoting fine, medium and coarse grids, respectively.
Spatial discretization sensitivity in Nu was quantified using the grid convergence index (GCI) formulation of Celik et al. [37]. For a three-dimensional mesh, the representative grid spacing is
h g = 1 N ∑ i = 1 N Δ V i 1 / 3 = V N 1 / 3 ,
where V is the fluid-domain volume and N is the number of cells; the solution variable is ϕ = Nu . For the common domain volume, r 21 = h g , 2 / h g , 1 = 1.238 and r 32 = h g , 3 / h g , 2 = 1.144 . The unequal-ratio apparent-order calculation gives p = 3.269 . With a safety factor of 1.25,
e a 21 = ϕ 1 − ϕ 2 ϕ 1 , GCI 21 = 1.25 e a 21 r 21 p − 1 × 100 % .
The corresponding medium/coarse expressions use e a 32 = | ϕ 2 − ϕ 3 | / | ϕ 2 | and r 32 . The resulting values are GCI 21 = 2.73 % for the 1622k/855k pair and GCI 32 = 1.39 % for the 855k/571k pair, referenced to the fine and medium grids, respectively. Both refinement ratios are below the recommended value of 1.3, and the two pairs do not establish a consistent asymptotic limit. The GCIs are therefore indicative estimates, not evidence that the medium mesh is more accurate than the fine mesh. The 855k-cell mesh was selected as a practical balance between computational cost and the observed sensitivity of Nu and f F .

2.4. Validation Benchmark

  • Four-point experimental comparison
The independent heat-transfer benchmark uses the D3 projected-area (PA) experimental series of Du et al. [38]. Four Nusselt numbers obtained with the present quasi-periodic inlet–outlet loop are compared with the experimental reference over the reported range 2089.966 ≤ Re ≤ 6597.217 . This separate benchmark is not an additional member of the 29-case parameter matrix. Table 6 lists the D3 benchmark dimensions, and Table 7 records the four numerical results, the corresponding supplied reference digitization and the reported signed differences, providing a multi-point assessment of the predicted D3 heat-transfer response.
Table 6. Dimensions of the D3 benchmark geometry. Reported experimental dimensions follow Du et al. [38]; CAD dimensions describe the supplied fluid-domain model. Nominal values are not manufacturing-tolerance or exact surface-matching claims.
Table 7. Four-point comparison of the present quasi-periodic calculation with the provisional digitization of D3-PA experimental results of Du et al. [38].
  • Experimental benchmark and data provenance
Du et al. report a D3 pressing depth of 2.0 mm, dimple pitch of 7.6 mm and dimple size of 2.0 mm, with a 90 ° layout and 0.25 mm plate thickness. The water–water experiment used vertical counterflow with cold- and hot-side inlet temperatures of 50 and 70 °C, respectively. The selected reference is the open blue triangle D3-PA series in Figure 4b of Du et al. [38], not the filled D3 effective-area (EA) markers, their fitted correlation, or their separate D1 numerical-validation results. PA and EA denote two area-based reductions of the same D3 experiment, not different dimple geometries. The comparisons below use the reference values reported in Table 7.
Figure 4. D3 validation unit cell visualized from the supplied CAD fluid domain: (a) isometric view with the nominal pressing depth b and approximate full vertical envelope H; (b) plan view with repeat lengths L x , L y and nominal dimple size D d . Linear dimensions are in millimeters. S d is the reported dimple pitch. Colors distinguish geometric surfaces and are not solution fields; the central circular footprint is excluded from the fluid.
Figure 4 shows the reconstructed D3 unit-cell fluid domain used for the benchmark, with its principal dimensions listed in Table 6. The supplied CAD has opposing cut planes separated by 7.60 mm in both in-plane directions and a nominal 2.00 mm central contact footprint. Its approximately 4.00 mm full vertical envelope describes both bounding walls and must not be interpreted as a uniform local channel gap or as the plate thickness. The 0.25 mm experimental plate thickness is reported for provenance only; no solid plate volume is included in this fluid-domain geometry.
Figure 5 shows the computational mesh of the D3 validation unit cell, comprising 894,592 cells.
Figure 5. Computational mesh of the D3 validation unit cell, comprising 894,592 cells.
  • Method-matched quasi-periodic calculation
The benchmark retains the steady, single-phase, pressure-based RANS formulation, SST k– ω closure and numerical scheme described in Section 2.1 and Section 2.2.3. The lateral faces form a translational periodic pair. In the streamwise direction, the velocity inlet and pressure outlet remain separate boundaries: outlet Cartesian velocity components, k and ω are mapped and scaled onto the inlet between calculation blocks using the existing quasi-periodic loop. The thermal treatment retains a fixed uniform inlet-temperature reset, prescribed isothermal heated walls and no outlet-to-inlet temperature-profile transfer. Hydrodynamic repeatability does not establish thermal periodicity.
The four benchmark points are at Re = 2089.966 , 4234.524 , 6137.484 and 6597.217 ; the parametric sweeps remain at Re = 4282 . For each benchmark point, the manuscript’s reference-speed relation is
u = Re μ ρ D e .
Here, D e follows Equation (1), using the D3 cell’s own A 0 , L and both wetted wall areas, not the parametric geometries’ 25 mm cell length. The profile-scaling speed u, actual inlet-normal bulk speed, net mass flow and mass flux must be distinguished and documented. Du et al. list D hyd = 4.0 mm and D eq = 3.18 mm and state that hydraulic diameter is used for their Reynolds and Nusselt numbers.
  • Heat-transfer reduction and the PA comparison
The primary numerical definition remains Equation (5), using both wall heat rates and wetted areas with the fluid-domain mass-average temperature T f , a v e , followed by Equation (6), Nu = h a v e D e / λ , where λ is water thermal conductivity. Selecting Du’s PA series does not change these parametric-study definitions. Du et al. infer their coefficient through exchanger heat-transfer/resistance reduction and evaluate properties at an inlet/outlet bulk-temperature mean.
  • Four-point heat-transfer comparison
In order of increasing Reynolds number, the present study gives Nu = 52.75 , 86.38 , 108.14 and 113.68 , compared with the digitized D3–PA experimental reference values 51.76 , 85.29 , 111.02 and 116.38 , respectively. Both sets increase monotonically over the four operating points. The signed tabulated difference is defined as
δ Nu = 100 Nu study − Nu Du , PA Nu Du , PA % .
The reported signed differences are + 1.92 % , + 1.28 % , − 2.60 % and − 2.32 % , respectively. The numerical predictions therefore slightly overestimate the experimental reference at the two lower Reynolds numbers and underestimate it at the two higher Reynolds numbers. Across all four points, the maximum absolute reported difference is 2.60 % and the mean absolute reported difference is 2.03 % .
The D3–PA results of Du et al. [38] are experimentally derived Nusselt numbers and thus provide an independent physical benchmark for validating the present numerical method. Agreement between computed and experimental Nusselt numbers at corresponding Reynolds numbers constitutes validation evidence for the unit-cell heat-transfer predictions, rather than merely agreement between numerical models. The reported four-point agreement therefore supports the method’s ability to reproduce both the measured heat-transfer level and its increase with Reynolds number over the sampled D3 range. This validation evidence is specific to the D3 heat-transfer response under the examined conditions. The close agreement over the sampled Reynolds-number range therefore shows that the present method and equations are valid for assessing heat transfer in this configuration.

3. Results and Discussion

The numerical simulations conducted in this study provide detailed insight into the thermo-hydraulic behavior of capsule-type and dimple-type plate heat exchangers under a variety of geometric configurations. By examining the influence of selected design parameters, namely the capsule angle and height in CPHE, and the dimple height and angle of flow in DPHE, the impact on flow structures, pressure drop, and heat transfer performance is assessed. Key fluid dynamic behaviors, including vortex generation, turbulence intensity, and recirculating flow patterns, are visualized through turbulence kinetic energy contours and streamline plots. Temperature distributions further reveal the relationship between geometric enhancements and thermal mixing. These findings enable the identification of design trends that balance improved heat transfer effectiveness with manageable pressure penalties, supporting the development of more efficient compact heat exchanger designs. Figure 6 provides an overview of the four parametric sweeps by comparing the friction factor and Nusselt number for capsule angle, capsule height, dimple height, and dimple angle. The following subsections relate these performance trends to the corresponding flow and temperature fields.
Figure 6. Fanning friction factor f F (blue) and two-wall Nusselt number Nu (orange), referenced to each case’s fluid-domain mass-average temperature, for the four parametric sweeps: (a) capsule-angle and dimple-angle sweeps and (b) normalized capsule-height and dimple-height sweeps.

3.1. CPHE Parametric Study

The CPHE study varies capsule angle and height. All four sweeps use the same constructed values as the PEC analysis: Nu is based on both heated walls and the case-specific fluid-domain mass-average temperature, and f F is the Fanning friction factor. Re = 4282 is maintained using the case-specific D e and a common cell length of 25 mm. The steady-state flow fields support interpretation of these trends; TKE alone does not quantify wall heat transfer.

3.1.1. Capsule Angle

For the capsule-angle sweep in Table 4, Figure 7 and Figure 8 show mid-plane TKE and streamlines at θ c = 0 ° , 22.5 ° , and 45 ° ; Figure 6a compares all seven angles.
Figure 7. TKE distribution of the middle z-axis section of CPHE at representative capsule angles ( θ c = 0 ° , 22.5 ° , and 45 ° ).
Figure 8. 2D streamlines of CPHE at representative capsule angles ( θ c = 0 ° , 22.5 ° , and 45 ° ).
At 0 ° , high-TKE bands flank an aligned central wake. At 22.5 ° , the wake becomes asymmetric and the deflected through-flow interacts with compact recirculation cells. At 45 ° , broader outer shear regions accompany larger separated and reattaching regions. The main effect of rotation is therefore to redistribute wake interactions and secondary flow, rather than increase TKE uniformly across the passage.
The response in Figure 6a is nonlinear. Both Nu and f F reach their largest sampled values at 22.5 ° (79.80 and 0.03072), 15.1% and 87.5% above the 0 ° case, respectively. Larger angles do not further increase Nu, despite the more extensive secondary flow. Because D e varies with angle, the Nu ranking need not match that of the dimensional heat-transfer coefficient or total heat release.

3.1.2. Capsule Height

The capsule-height sweep covers h c = 2 –5 mm ( h c / l c = 0.08 – 0.20 ) at θ c = 22.5 ° . Figure 9 and Figure 10 compare TKE and temperature fields at height ratios of 0.08, 0.14, and 0.20.
Figure 9. TKE distribution of the middle z-axis section of CPHE at representative normalized capsule heights ( h c / l c = 0.08 , 0.14 , and 0.20 ).
Figure 10. Temperature distribution of CPHE at representative normalized capsule heights ( h c / l c = 0.08 , 0.14 , and 0.20 ).
As capsule height increases, the broad outer high-TKE lanes in Figure 9 weaken, and the strongest activity becomes concentrated near the central wake. This localization contrasts with a uniform increase in turbulence throughout the channel.
The warmer-fluid regions in Figure 10 shift from the convex-capsule wake towards the concave cavities as height increases, while the channel core remains comparatively cool.
Figure 6b shows an overall but nonlinear increase in Nu with capsule height. The 5 mm capsule gives the highest tested Nu (91.83), whereas the friction factor peaks at 2.5 mm ( f F = 0.03072 ). Across the 2–5 mm endpoints, Nu increases by 30.0% and f F by 42.3%.
These normalized trends differ from the dimensional response: as D e grows and the prescribed speed falls at fixed Re, the mean heat-transfer coefficient, total wall heat rate, and pressure drop all decrease between the endpoints. Higher Nu therefore does not imply greater heat duty in this height sweep.

3.2. DPHE Parametric Study

The DPHE study varies dimple height and the angle of flow relative to the dimple array.

3.2.1. Dimple Height

The dimple-height sweep covers h d = 2 –5 mm ( h d / l d = 0.08 – 0.20 ) at θ d = 0 ° . Figure 11 and Figure 12 compare mid-plane TKE and three-dimensional temperature fields at height ratios of 0.08, 0.14, and 0.20.
Figure 11. TKE distribution of the middle z-axis section of DPHE at representative normalized dimple heights ( h d / l d = 0.08 , 0.14 , and 0.20 ).
Figure 12. Three-dimensional temperature distribution of DPHE at representative normalized dimple heights ( h d / l d = 0.08 , 0.14 , and 0.20 ).
Increasing dimple height localizes the high-TKE regions near the dimple rims and outer boundaries, leaving more of the central passage at low-to-intermediate TKE (Figure 11). The strongest wake interactions become less spatially extensive rather than producing a section-wide rise in turbulence.
In Figure 12, the warmed-fluid plume extends farther across the passage as dimple height increases. This shows how heating is redistributed between the opposing surfaces, not an increase in the wall-integrated heat rate.
Unlike the capsule-height sweep, both Nu and f F increase monotonically with dimple height (Figure 6b). Across 2–5 mm, Nu increases by 62.7% to 104.09, while f F increases by 169.7% to 0.07133. The relative rise in friction is therefore substantially larger than that in Nu. As in the capsule-height sweep, however, increasing D e and decreasing speed at fixed Re accompany lower dimensional heat-transfer coefficients, total wall heat rates, and pressure drops between the endpoints.

3.2.2. Dimple Angle

Although each circular dimple is axisymmetric, changing the flow direction relative to the array alters the interaction between neighboring convex and concave wakes [4,5]. Figure 13 compares TKE at θ d = 0 ° , 22.5 ° , and 45 ° . The nearly symmetric low-TKE corridor at 0 ° becomes an oblique wake bordered by a concentrated high-TKE band at 22.5 ° . At 45 ° , a coherent diagonal corridor forms, with high TKE more localized near the dimples.
Figure 13. TKE distribution of the middle z-axis section of DPHE at representative angles of flow ( θ d = 0 ° , 22.5 ° , and 45 ° ).
The streamlines in Figure 14 show compact, locally confined recirculation at 0 ° , larger structures interacting with the oblique through-flow at 22.5 ° , and a more coherent diagonal passage at 45 ° . The latter bypasses much of the stronger wake interaction, consistent with reduced resistance and heat transfer.
Figure 14. Two-dimensional streamlines of DPHE at representative angles of flow ( θ d = 0 ° , 22.5 ° , and 45 ° ).
Figure 6a shows a non-monotonic response: Nu peaks at 30 ° (106.37), while f F peaks at 22.5 ° (0.06503). The 2.6% Nu difference between these angles does not establish a resolved optimum without quantified numerical uncertainty. Both measures decline beyond 30 ° , reaching their lowest values at 45 ° : Nu is 9.6% and f F is 59.2% below the 0 ° values. Because D e and the reference speed remain fixed in this sweep, these trends also track the mean heat-transfer coefficient and pressure drop.

3.3. Cross-Parameter Thermo-Geometric Comparison

Figure 15 and Figure 16 compare the constructed PEC values for the angle and normalized-height sweeps. All three PEC plots, including Figure 17, use the same two-wall coefficient and case-specific fluid-domain mass-average reference convention, together with the prescribed-Reynolds-number velocity defined in Section 2.1. The 29 case labels contain 27 distinct saved solutions because two sweep reference points are shared. The dimple-angle sweep reaches its highest PEC at θ d = 45 ° (285.19). The targeted combined case therefore pairs this angle with h d = 5.0 mm instead of the angle sweep’s fixed height of 3.5 mm.
Figure 15. Two-wall PEC referenced to the fluid-domain mass-average temperature for the angle sweeps: h c = 2.5 mm and h d = 3.5 mm.
Figure 16. Two-wall PEC referenced to the fluid-domain mass-average temperature for the height sweeps: θ c = 22.5 ° and θ d = 0 ° .
Figure 17. Performance evaluation criterion (PEC = Nu/ f F 1 / 3 ) versus relative embossing depth (RED = h / D e ). The star denotes θ d = 45 ° , h d = 5.0 mm. All scores use both heated walls and case-specific T ref = T f , a v e , the fluid-domain mass-average temperature. These are constructed unit-cell scores, not thermally fully developed coefficients or uncertainty-resolved rankings.
To quantify the paired separation in Figure 15 and Figure 16, the matched-case PEC difference is defined as
Δ PEC = PEC CPHE − PEC DPHE ,
where positive values indicate a higher CPHE score on the stated reporting basis. Equation (11) is a paired-difference definition introduced here. Ordinary least-squares regression [39] of the seven matched numerical angles gives
Δ PEC θ = 33.695 − 1.42984 θ 1 ° , 0 ° ≤ θ ≤ 45 ° ,
with R 2 = 0.973 and RMSE = ∑ i = 1 7 e i 2 / 7 = 3.54 , where e i is the fitted residual. The actual endpoint differences are 39.04 at 0 ° and − 30.61 at 45 ° ; the paired differences decrease across the seven sampled angles. The fitted coefficients are results of the present reconstruction; the cited source supplies the regression method, not these coefficients.
For the seven matched normalized heights, h c / l c = h d / l d = 0.08 – 0.20 , Δ PEC h remains positive but scattered. Its mean is 42.01, sample standard deviation 7.77 and range 30.36–53.94. A linear height fit has only R 2 = 0.087 , so the height result is reported as a descriptive offset. The angle fit is an empirical summary of seven paired cases, not an independently validated predictive correlation; neither its R 2 nor its RMSE quantifies CFD uncertainty.
These results are limited to the present one-factor sweeps at Re = 4282 : the angle comparison pairs the CPHE cases at h c = 2.5 mm with the DPHE cases at h d = 3.5 mm, and the height comparison pairs the CPHE cases at θ c = 22.5 ° with the DPHE cases at θ d = 0 ° . They do not describe angle–height interactions and should not be extrapolated to other Reynolds numbers, unit-cell geometries, fluids, or boundary conditions.
Figure 15, Figure 16 and Figure 17 use a single saved-field postprocessing basis of D e = 4 A 0 L / ( S 1 + S 2 ) , U = 4282 μ / ( ρ D e ) , and h a v e = ( Q 1 + Q 2 ) / [ ( S 1 + S 2 ) ( T w − T f , a v e ) ] with T ref = T f , a v e evaluated as the mass-weighted volume average of static temperature over the entire fluid domain of each case. Thus, both walls enter the heat-transfer coefficient as well as the hydraulic-diameter definition. The prescribed reference velocity is corroborated by the finite embedded inlet profiles, including the combined case.
The constructed two-wall PEC ranges are 254.6–273.0 for capsule angle, 254.8–294.6 for capsule height, 214.8–251.0 for dimple height, and 234.0–285.2 for dimple angle. The combined dimple case gives RED = 0.357856, Nu = 87.38, f F = 0.023480 , and PEC = 305.14. It has the highest constructed score, followed by the h c = 5.0 mm capsule case at PEC = 294.64. Their separation is 3.56%; without quantified numerical uncertainty, this is not interpreted as a resolved superiority or a global optimum. Height sweeps span different RED values, and the measured capsule-angle hydraulic diameter also changes. All dimple-angle cases share the same geometry and RED, so RED alone cannot identify the flow-entry angle. These scores characterize the saved, thermally developing unit-cell heating problem with periodic hydrodynamics; they do not establish thermally fully developed periodic heat transfer.

3.4. Limitations of This Study

Exploring the intricacies of heat exchanger designs through numerical investigations can be incredibly enlightening, yet it is important to remember that these methods are not without their flaws. Recognizing these limitations helps us to better understand the results and spot areas that need more research and real-world testing.
For instance, our study assumes that the working fluid does not compress, making the calculations simpler. However, this assumption does not hold up for all real-world scenarios, especially when dealing with gases or other compressible fluids. Additionally, our simulations only consider single-phase flow, meaning that they do not take into account the complexities that come with multiphase flows like liquid–gas, or solid–liquid. These interactions can drastically change heat transfer and pressure drops. Moreover, the boundary conditions that we apply in simulations tend to be idealized. They do not always reflect the varied and sometimes chaotic conditions found in real-life operations, such as changing inlet temperatures or pressures, and leakage or local geometry variations. We also assume that the physical properties of the working fluid, like density, viscosity, and thermal conductivity, remain constant. In reality, these properties can change significantly with temperature and pressure, which affects both flow and heat transfer.
Section 2.4 compares four quasi-periodic Nusselt numbers with the D3 projected-area (PA) data of Du et al. The reported differences lie between − 2.60 % and + 1.92 % , with a mean absolute value of 2.03 % (Table 7). This close agreement shows that the present method and equations are valid for assessing heat transfer. The comparison is, however, made against a digitized reference whose coordinates were not fully reproduced by an independent reading of the original plot.

4. Conclusions

The central contribution of this study is a direct, side-by-side comparison of capsule-type (CPHE) and dimple-type (DPHE) channels under a common numerical and operating baseline. It addresses the comparison gap left by separate studies with differing conditions and reporting definitions. Both surface families were assessed using the same steady-state, single-phase water-flow RANS framework, unit-cell approach, thermal boundary conditions and performance definitions at Re = 4282 . Four seven-case, one-factor sweeps examined capsule angle ( θ c ), capsule height ( h c ), dimple height ( h d ), and dimple flow-entry angle ( θ d ), with one targeted combined dimple case. The comparative contribution lies in quantifying the geometry-dependent thermal–hydraulic trade-offs across both surface families using established Nu, Fanning friction and PEC measures, supported by the computed flow and temperature fields.
Across the 2–5 mm height endpoints, capsule Nu and f F increase by 30.0% and 42.3%, respectively, compared with 62.7% and 169.7% for dimples. These paired changes quantify the different normalized heat-transfer–resistance responses of the two height sweeps. They are not increases in absolute heat duty or pressure drop, because the hydraulic diameter and reference speed also vary at fixed Re.
On the common two-wall, case-specific fluid-domain mass-average reference basis, capsule-angle PEC spans 254.6–273.0, while capsule-height PEC spans 254.8–294.6. The dimple-angle and dimple-height ranges are 234.0–285.2 and 214.8–251.0, respectively. The highest capsule-height score occurs at h c = 5.0 mm. These differences apply to the prescribed reference-speed, hydraulic-diameter and coefficient definitions used in this comparison.
For matched numerical angles, the least-squares descriptor is Δ PEC θ = 33.695 − 1.42984 ( θ / 1 ° ) with R 2 = 0.973 and RMSE 3.54 over 0 ° – 45 ° . The actual paired differences decrease across the sampled angles. Matched normalized-height differences remain positive, averaging 42.01 with a sample standard deviation of 7.77 across h / l = 0.08 – 0.20 ; their linear fit has R 2 = 0.087 . These are descriptive results for the tested one-factor cases, not validated correlations for other geometries or operating conditions.
The targeted combination θ d = 45 ° , h d = 5.0 mm gives PEC = 305.14, the highest constructed score. It is 6.99% above the corresponding 3.5 mm dimple-angle case and 21.57% above the 5.0 mm dimple-height case at 0 ° . Its score is 3.56% above the 5.0 mm capsule case (294.64); a numerically resolved superiority is not established without quantified uncertainty.
These findings are specific to the tested 0 ° – 45 ° angles, 2–5 mm heights, water properties, Re = 4282 and unit-cell boundary conditions. Four one-factor sweeps and one combined case do not establish a global optimum across untested parameter interactions. The thermal results characterize heating with a prescribed inlet temperature and a streamwise quasi-periodic iteration loop for velocity and turbulence profiles; they do not establish thermal periodicity. The close agreement of the four-point comparison with the D3–PA experimental data of Du et al. [38], with a maximum absolute difference of 2.60%, shows that the present method and equations are valid for assessing heat transfer. Quantified uncertainties and tests at further Reynolds numbers, heights, angles and fluids are advised before the parametric results can be regarded as fully experimentally validated.

Author Contributions

Both C.S.C. and C.S. have similar contributions to the paper and are acknowledged as the first authors. Conceptualization, S.V. and L.S.; methodology, S.V., K.I., A.D. and J.T.; software, C.S.C. and C.S.; formal analysis, C.S.C. and C.S.; investigation, C.S.C. and C.S.; resources, L.S.; data curation, C.S.C. and C.S.; writing: original draft preparation, C.S.C. and C.S.; writing: review and editing, S.V., A.D. and K.I.; visualization, C.S.C. and C.S.; supervision, L.S., S.V., K.I., J.T. and A.D.; project administration, S.V. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Data Availability Statement

The data presented in this study are available on request from the corresponding author.

Acknowledgments

The authors acknowledge InKorr Pty Ltd. for providing resources for this research.

Conflicts of Interest

Author Mr. Lance Smith was employed by the company InKorr Pty Ltd., Melbourne, Australia. The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Nomenclature

SymbolDescriptionSymbolDescription
ACross-sectional flow area (mm2)NuNusselt number (–)
A 0 Adopted inlet flow area (mm2)PWetted perimeter (mm)
CUnit-cell centerPECPerformance evaluation criterion (–)
C p Specific heat capacity (J/kg·K)PrPrandtl number (–)
DDimple diameter (mm) Q f , Q j Fluid energy gain; wall-j heat rate (W)
D e Hydraulic diameter (mm)ReReynolds number (–)
f, f F Fanning friction factor (–) Re x Local Reynolds number (–)
hEmbossing height (mm)REDRelative embossing depth (–)
h a v e Two-wall, fluid-temperature-referenced heat-transferSTotal heated wall area, S 1 + S 2 (mm2)
coefficient (W/m2 · K)
h c Capsule height (mm) T f , a v e Fluid-domain mass-average temperature (K)
h d Dimple height (mm) T f , i n Fluid inlet temperature (K)
kTurbulence kinetic energy (m2/s2) T f , o u t Fluid outlet temperature (K)
lCapsule length (mm) T w Wall temperature (K)
l c Capsule unit-cell length (mm)uPrescribed reference mean speed (m/s)
l d , LDimple/common unit-cell length (mm)wCapsule width (mm)
m ˙ Mass flow rate (kg/s)xStreamwise distance (m)
T ref Coefficient reporting temperature (K) y + Dimensionless wall distance (–)
Greek symbols Abbreviations
δ Boundary-layer thickness (m)CFDComputational fluid dynamics
Δ p Pressure drop (Pa)CPHECapsule-type plate heat exchanger
Δ PEC Difference between matched CPHE and DPHE PEC
values (–)
ϵ Turbulence dissipation rate (m2/s3)DPHEDimple-type plate heat exchanger
θ c Capsule angle (°)HVACHeating, ventilation, and air-conditioning
θ d Dimple angle (°)PHEPlate heat exchanger
λ Thermal conductivity (W/m·K)RANSReynolds-averaged Navier–Stokes
ρ Fluid density (kg/m3)SSTShear Stress Transport
υ Kinematic viscosity (m2/s)STHEShell-and-tube heat exchanger
ω Specific dissipation rate (s−1)TKETurbulence kinetic energy

References

  1. Abu-Khader, M.M. Plate heat exchangers: Recent advances. Renew. Sustain. Energy Rev. 2012, 16, 1883–1891. [Google Scholar] [CrossRef] [Scilit]
  2. Thulukkanam, K. Heat Exchanger Design Handbook; Taylor & Francis Group: Boca Raton, FL, USA, 2013. [Google Scholar]
  3. Zhang, J.; Zhu, X.; Mondejar, M.E.; Haglind, F. A review of heat transfer enhancement techniques in plate heat exchangers. Renew. Sustain. Energy Rev. 2019, 101, 305–328. [Google Scholar] [CrossRef] [Scilit]
  4. Hamedi, H.; Setayeshfar, B.; Sadat, M.; Farshidianfar, A.; Mahvan, A.; Asadi, M. Experimental and numerical analysis of the thermo-hydraulic performance of a cross-flow air-to-gas capsule-type plate heat exchanger. Appl. Therm. Eng. 2024, 236, 121900. [Google Scholar] [CrossRef] [Scilit]
  5. Jiang, C.; Zhou, W.; Tang, X.; Bai, B. Influence of capsule length and width on heat transfer in capsule-type plate heat exchangers. Adv. Mech. Eng. 2019, 11, 168781401989574. [Google Scholar] [CrossRef] [Scilit]
  6. Jiang, C.; Bai, B.; Wang, H.; Shi, J.; Tang, X.; Zhou, W. Heat transfer enhancement of plate heat exchangers with symmetrically distributed capsules to generate counter-rotating vortices. Int. J. Heat Mass Transf. 2020, 151, 119455. [Google Scholar] [CrossRef] [Scilit]
  7. Zhang, Y.; Jiang, C.; Yang, Z.; Zhang, Y.; Bai, B. Numerical study on heat transfer enhancement in capsule-type plate heat exchangers. Appl. Therm. Eng. 2016, 108, 1237–1242. [Google Scholar] [CrossRef] [Scilit]
  8. Yu, C.; Shao, M.; Zhang, W.; Wang, G.; Huang, M. Study on Heat Transfer Synergy and Optimization of Capsule-Type Plate Heat Exchangers. Processes 2024, 12, 604. [Google Scholar] [CrossRef] [Scilit]
  9. Shao, Z.; Zhang, D.; Meng, Y.; Wan, Y.; Jiang, W. Thermal-Hydraulic and Entropy Generation Optimization of Capsule-Type Plate Heat Exchangers with Spherical Dimples. Heat Transf. Eng. 2024, 45, 690–704. [Google Scholar] [CrossRef] [Scilit]
  10. Arsenyeva, O.; Piper, M.; Zibart, A.; Olenberg, A.; Kenig, E.Y. Investigation of heat transfer and hydraulic resistance in small-scale pillow-plate heat exchangers. Energy 2019, 181, 1213–1224. [Google Scholar] [CrossRef] [Scilit]
  11. Piper, M.; Zibart, A.; Dajakow, E.; Springer, R.; Homberg, W.; Kenig, E.Y. Heat transfer enhancement in pillow-plate heat exchangers with dimpled surfaces: A numerical study. Appl. Therm. Eng. 2019, 153, 142–146. [Google Scholar] [CrossRef] [Scilit]
  12. Soman, D.P.; Karthika, S.; Valan, D.T.; Kalaichelvi, P.; Radhakrishnan, T.K. Computational Fluid Dynamics Modelling and Analysis of Heat Transfer in Multichannel Dimple Plate Heat Exchanger. Appl. Therm. Eng. 2022, 165, 114254. [Google Scholar]
  13. Ying, P.; He, Y.; Tang, H.; Ren, Y. Numerical and experimental investigation of flow and heat transfer in heat exchanger channels with different dimples geometries. Machines 2021, 9, 72. [Google Scholar] [CrossRef] [Scilit]
  14. Mocnik, U.; Blagojevic, B.; Muhic, S. Numerical Analysis with Experimental Validation of Single-Phase Fluid Flow in a Dimple Pattern Heat Exchanger Channel. J. Mech. Eng. 2020, 66, 544–553. [Google Scholar] [CrossRef] [Scilit]
  15. Mocnik, U.; Muhic, S. Experimental and numerical analysis of heat transfer in a dimple pattern heat exchanger channel. Appl. Therm. Eng. 2023, 230, 120865. [Google Scholar] [CrossRef] [Scilit]
  16. Mocnik, U.; Cikic, A.; Muhic, S. Numerical and experimental analysis of fluid flow and flow visualization at low Reynolds numbers in a dimple pattern plate heat exchanger. Energy 2024, 228, 129812. [Google Scholar] [CrossRef] [Scilit]
  17. Jing, Q.; Xie, Y.; Zhang, D. Thermal-hydraulic performance and entropy generation of supercritical carbon dioxide in heat exchanger channels with teardrop dimple/protrusion. Int. J. Heat Mass Transf. 2019, 135, 1082–1096. [Google Scholar] [CrossRef] [Scilit]
  18. Li, X.; Sun, J.; Xu, C.; Li, Y.; Zhang, R.; Qian, L.; Chen, Y. Visualization of bubble flow in the channel of a dimple-type embossing plate heat exchanger under different fluid inlet/outlet ports. Int. J. Heat Mass Transf. 2019, 145, 118750. [Google Scholar] [CrossRef] [Scilit]
  19. Soman, D.P.; Kalaichelvi, K.P.; Radhakrishnan, T.K. Experimental study of turbulent forced convection heat transfer and friction factor in dimpled plate heat exchanger. Appl. Therm. Eng. 2019, 162, 114254. [Google Scholar] [CrossRef] [Scilit]
  20. Torre, D.; Montenegro, G.; Onorati, A.; Khadilkar, S.; Icarelli, R. Multi-Scale CFD Modeling of Plate Heat Exchangers Including Offset-Strip Fins and Dimple-Type Turbulators for Automotive Applications. Energies 2019, 12, 2965. [Google Scholar] [CrossRef] [Scilit]
  21. Kanaris, A.G.; Mouza, A.A.; Paras, S.V. Flow and Heat Prediction in a Corrugated Plate Heat Exchanger using a CFD Code. Chem. Eng. Technol. 2006, 29, 923–930. [Google Scholar] [CrossRef] [Scilit]
  22. Menter, F.R. Two-equation Eddy-Viscosity Turbulence Models for Engineering Applications. AIAA J. 1994, 32, 1598–1605. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  23. Jiang, C.; Bai, B. Flow patterns and pressure drop of downward two-phase flow in a capsule-type plate heat exchanger. Exp. Therm. Fluid Sci. 2019, 103, 347–354. [Google Scholar] [CrossRef] [Scilit]
  24. Shirzad, M.; Delavar, M.A.; Ajarostaghi, S.S.M.; Sedighi, K. Evaluation the effects of geometrical parameters on the performance of pillow plate heat exchanger. Chem. Eng. Res. Des. 2019, 150, 74–83. [Google Scholar] [CrossRef] [Scilit]
  25. Shirzad, M.; Ajarostaghi, S.S.M.; Delavar, M.A.; Sedighi, K. Improve the thermal performance of the pillow plate heat exchanger by using nanofluid: Numerical simulation. Adv. Powder Technol. 2019, 30, 1356–1365. [Google Scholar] [CrossRef] [Scilit]
  26. Kumar, S.; Premachandran, B.; Subbarao, P.M.V. Study on thermo-hydraulics in a Pillow Plate Channel. Int. J. Therm. Sci. 2019, 145, 106020. [Google Scholar] [CrossRef] [Scilit]
  27. Wang, Y.; Li, S.; Xie, X.; Deng, Y.; Liu, X.; Su, C. Performance evaluation of an automotive thermoelectric generator with inserted fins or dimpled-surface hot heat exchanger. Appl. Energy 2019, 218, 391–401. [Google Scholar] [CrossRef] [Scilit]
  28. Khail, A.A.; Erisen, A. A Review: CFD Approaches of Plate Heat Exchangers. Arch. Comput. Methods Eng. 2023, 30, 1157–1165. [Google Scholar] [CrossRef] [Scilit]
  29. Zohuri, B. Compact Heat Exchangers: Selection, Application, Design and Evaluation; Springer International Publishing: Cham, Switzerland, 2017. [Google Scholar]
  30. Cengel, Y.A.; Cimbala, J.M. Fluid Mechanics: Fundamentals and Applications, 3rd ed.; McGraw-Hill: New York, NY, USA, 2014. [Google Scholar]
  31. Ansys, Inc. Ansys Fluent Theory Guide, Release 2025 R2; Sections 25.1 (Fluxes Through Boundaries), 25.3.1 (Computing Surface Integrals) and 25.4.1 (Computing Volume Integrals), especially Equations 25–16, 25–17 and 25–39; Ansys, Inc.: Canonsburg, PA, USA, 2025. [Google Scholar]
  32. Ansys, Inc. Ansys Fluent User’s Guide, Release 2025 R2; Sections 17.2.3.5 (Reporting Averaged Heat Transfer Coefficients) and 43.4 (Surface Heat Transfer Coef., Equation 43–50); Ansys, Inc.: Canonsburg, PA, USA, 2025. [Google Scholar]
  33. Alfa Laval. Alfa Laval Gasketed Plate Heat Exchanger. 2022. Available online: https://www.alfalaval.com/globalassets/documents/local/united-states/heat-transfer/gasketed-plate-and-frame-heat-exchangers/alfa-laval—gphe-catalog-2022.pdf (accessed on 7 August 2026).
  34. Sorgente, T.; Biasotti, S.; Manzini, G.; Spagnuolo, N. A Survey of Indicators for Mesh Quality Assessment. Comput. Graph. Forum 2023, 42, 461–483. [Google Scholar] [CrossRef] [Scilit]
  35. Juretic, F.; Gosman, A.D. Error Analysis of the Finite-Volume Method with Respect to Mesh Type. Numer. Heat Transf. Part B Fundam. 2010, 57, 414–439. [Google Scholar] [CrossRef] [Scilit]
  36. Eca, L.; Pereira, F.S.; Vaz, G. Viscous flow simulations at high Reynolds numbers with wall functions: Is y+ 1 enough for the near-wall cells? Comput. Fluids 2018, 170, 157–175. [Google Scholar] [CrossRef] [Scilit]
  37. Celik, I.B.; Ghia, U.; Roache, P.J.; Freitas, C.J.; Coleman, H.; Raad, P.E. Procedure for Estimation and Reporting of Uncertainty Due to Discretization in CFD Applications. J. Fluids Eng. 2008, 130, 078001. [Google Scholar] [CrossRef] [Scilit]
  38. Du, Y.; Wei, W.; Xu, C.; Wang, Y.; Li, X. Heat transfer characteristics of single-phase flow through dimple plate heat exchanger. Appl. Therm. Eng. 2025, 273, 126499. [Google Scholar] [CrossRef] [Scilit]
  39. NIST/SEMATECH. e-Handbook of Statistical Methods: Linear Least Squares Regression; Section 4.1.4.1; National Institute of Standards and Technology: Gaithersburg, MD, USA, 2020. [Google Scholar]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics