Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

remove_circle_outline
remove_circle_outline
remove_circle_outline

Search Results (284)

Search Parameters:
Keywords = plate heat exchangers

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
23 pages, 2663 KiB  
Article
How Nanofluids May Enhance Energy Efficiency and Carbon Footprint in Buildings?
by Sylwia Wciślik
Sustainability 2025, 17(15), 7035; https://doi.org/10.3390/su17157035 (registering DOI) - 2 Aug 2025
Abstract
Nanofluids are an innovative working medium in solar hot water installations (DHWs), thanks to their increased thermal conductivity and heat transfer coefficient. The aim of this work was to assess the effect of Al2O3 nanofluids in a water–ethylene glycol base [...] Read more.
Nanofluids are an innovative working medium in solar hot water installations (DHWs), thanks to their increased thermal conductivity and heat transfer coefficient. The aim of this work was to assess the effect of Al2O3 nanofluids in a water–ethylene glycol base (40:60%) and with the addition of Tween 80 surfactant (0.2 wt%) on thermal efficiency (ε) and exergy (ηex) in a plate heat exchanger at DHW flows of 3 and 12 L/min. The numerical NTU–ε model was used with dynamic updating of thermophysical properties of nanofluids and the solution of the ODE system using the ode45 method, and the validation was carried out against the literature data. The results showed that the nanofluids achieved ε ≈ 0.85 (vs. ε ≈ 0.87 for the base fluid) and ηex ≈ 0.72 (vs. ηex ≈ 0.74), with higher entropy generation. The addition of Tween 80 reduced the viscosity by about 10–15%, resulting in a slight increase of Re and h-factor; however, the impact on ε and ηex was marginal. The environmental analysis with an annual demand of Q = 3000 kWh/year and an emission factor of 0.2 kg CO2/kWh showed that for ε < 0.87 the nanofluids increased the emissions by ≈16 kg CO2/year, while at ε ≈ 0.92, a reduction of ≈5% was possible. This paper highlights the need to optimize nanofluid viscosity and exchanger geometry to maximize energy and environmental benefits. Nowadays, due to the growing problems of global warming, the analysis of energy efficiency and carbon footprint related to the functioning of a building seems to be crucial. Full article
Show Figures

Figure 1

20 pages, 3890 KiB  
Article
Numerical Analysis of Pressure Drops in Single-Phase Flow Through Channels of Brazed Plate Heat Exchangers with Dimpled Corrugated Plates
by Lorenzo Giunti, Francesco Giacomelli, Urban Močnik, Giacomo Villi, Adriano Milazzo and Lorenzo Talluri
Appl. Sci. 2025, 15(15), 8431; https://doi.org/10.3390/app15158431 (registering DOI) - 29 Jul 2025
Viewed by 165
Abstract
The presented research examines the performance characteristics of Brazed Plate Heat Exchangers through computational fluid dynamics (CFD), focusing on pressure drop calculations for single-phase flow within full channels of plates featuring dimpled corrugation. This work aims to bridge gaps in the literature, particularly [...] Read more.
The presented research examines the performance characteristics of Brazed Plate Heat Exchangers through computational fluid dynamics (CFD), focusing on pressure drop calculations for single-phase flow within full channels of plates featuring dimpled corrugation. This work aims to bridge gaps in the literature, particularly regarding the underexplored behavior near the ports for the studied technology and establishing a framework for future conjugate heat transfer studies. A methodology for the domain generation was developed, integrating a preliminary forming simulation to reproduce the complex plate geometry. Comprehensive sensitivity analyses were conducted to evaluate the influence of different parameters and identify the optimal settings for obtaining reliable results. The findings indicate that the kε realizable turbulence model with enhanced wall treatment offers superior accuracy in predicting pressure drops, with errors within ±4.4%. Additionally, leveraging the information derived from CFD, a strategy to estimate contributions from different channel sections without a direct reliance on those simulations was developed, offering practical implications for plate design. Full article
Show Figures

Figure 1

18 pages, 4285 KiB  
Article
Application of a Phase-Change Material Heat Exchanger to Improve the Efficiency of Heat Pumps at Partial Loads
by Koharu Tani, Sayaka Kindaichi, Keita Kawasaki and Daisaku Nishina
Energies 2025, 18(14), 3694; https://doi.org/10.3390/en18143694 - 12 Jul 2025
Viewed by 335
Abstract
Inverter-equipped heat pumps allow for increased energy efficiency. However, air conditioning (AC) systems often operate at low load ratios below where inverter control is effective, which reduces their energy efficiency. We developed an AC system that increases the apparent load ratio of the [...] Read more.
Inverter-equipped heat pumps allow for increased energy efficiency. However, air conditioning (AC) systems often operate at low load ratios below where inverter control is effective, which reduces their energy efficiency. We developed an AC system that increases the apparent load ratio of the heat pump by using a phase-change material (PCM). Cooling and heating experiments were conducted with a PCM heat exchanger, which comprised aluminum plates and fins filled with paraffinic PCM. The result indicated a high heat transfer coefficient of >70 W/(m2·K). A simplified numerical model of the PCM heat exchanger as a lumped constant system was created based on the experiment. The calculations generally reproduced the experimental results, with root mean squared errors of 0.39 K for cooling and 0.84 K for heating, confirming their accuracy. Simulations were then conducted to evaluate the energy performance of the proposed system for the cooling season. While low load operation accounted for 39% of the total AC time for a non-PCM system, it was reduced to 2.7% for the proposed system. The proposed system demonstrated load ratios of 50–60% for most of the season, achieving an energy reduction of 11.4% owing to the improved efficiency at partial load ratios. Full article
(This article belongs to the Section J1: Heat and Mass Transfer)
Show Figures

Figure 1

18 pages, 4189 KiB  
Article
Cross-Scale Simulation Study of Porous Medium Heat Exchangers Based on Reliable Cell Selection
by Yiqiang Liang, Jun Zhang, Yu Liu, Mingrui Sun and Yongchen Song
Energies 2025, 18(13), 3510; https://doi.org/10.3390/en18133510 - 3 Jul 2025
Viewed by 304
Abstract
This study compares the heat transfer and pressure drop of three cell structures, namely Kelvin cells (KCs), ellipsoidal Kelvin cells (EKCs), and body-centered cubic (BCC) structures, at the cell scale in order to identify the superior configuration. Then, we conducted numerical simulations on [...] Read more.
This study compares the heat transfer and pressure drop of three cell structures, namely Kelvin cells (KCs), ellipsoidal Kelvin cells (EKCs), and body-centered cubic (BCC) structures, at the cell scale in order to identify the superior configuration. Then, we conducted numerical simulations on the heat exchangers based on porous media, and evaluate their comprehensive performance. It is shown that KCs have a superior heat transfer. Their volumetric heat transfer coefficient (hV) is more than 50% higher than that of EKCs and more than 100% higher than that of BCC structures. EKCs exhibit a lower pressure drop. In the heat exchanger performance optimization study, the Kelvin structure demonstrated significant heat transfer characteristics. Simulation data show that the heat transfer performance at the hot end of the Kelvin heat exchanger (KCHE) is enhanced by more than 40% compared to the conventional plate-fin structure (FHE), but its flow channel pressure drop characteristics show a significant nonlinear increase. It is noteworthy that the improved Kelvin heat exchanger (EKCHE), optimized by introducing elliptic cell topology, maintains heat transfer while keeping the pressure loss increase within 1.22 times that of the conventional structure. The evaluation of the heat transfer and pressure drop characteristics is consistent for both scales. In addition, the EKC configuration exhibits a superior overall heat transfer capacity. To summarize, this work proposes a systematic numerical framework encompassing cell unit screening through heat exchanger design, offering valuable guidance for the structured development and analysis of porous media heat exchangers in relevant engineering domains. Full article
(This article belongs to the Collection Advances in Heat Transfer Enhancement)
Show Figures

Figure 1

23 pages, 3114 KiB  
Article
Heat Transfer Enhancement in Flue-Gas Systems with Radiation-Intensifying Inserts: An Analytical Approach
by Justina Menkeliūnienė, Rolandas Jonynas, Linas Paukštaitis, Algimantas Balčius and Kęstutis Buinevičius
Energies 2025, 18(13), 3383; https://doi.org/10.3390/en18133383 - 27 Jun 2025
Viewed by 349
Abstract
A significant portion of energy losses in industrial systems arises from the inefficient use of high-temperature exhaust gases, emphasizing the need for enhanced heat recovery strategies. This study aims to improve energy efficiency by examining the effects of radiation-intensifying inserts on combined radiative [...] Read more.
A significant portion of energy losses in industrial systems arises from the inefficient use of high-temperature exhaust gases, emphasizing the need for enhanced heat recovery strategies. This study aims to improve energy efficiency by examining the effects of radiation-intensifying inserts on combined radiative and convective heat transfer in flue-gas heated channels. A systematic literature review revealed a research gap in understanding the interaction between these mechanisms in flue-gas heat exchangers. To address this, analytical calculations were conducted for two geometries: a radiation-intensifying plate between parallel plates and the same insert in a circular pipe. The analysis covered a range of gas-flue and wall temperatures (560–1460 K and 303–393 K, respectively), flow velocities, and spectral emissivity values. Key performance metrics included Reynolds and Nusselt numbers to assess flow resistance and heat transfer. Results indicated that flue-gas temperature has the most significant effect on total rate of heat transfer, and the insert significantly enhanced radiative heat transfer by over 60%, increasing flow resistance. A local Nusselt number minimum at a length-to-diameter ratio of approximately 26 suggested transitional flow behavior. These results provide valuable insights for the design of high-temperature heat exchangers, with future work planned to validate the findings experimentally. Full article
Show Figures

Figure 1

22 pages, 6648 KiB  
Article
Conjugate Heat Transfer Modelling in a Centrifugal Compressor for Automotive Applications
by Carlo Cravero, Pierre-Alain Hoffer, Davide Marsano, Daniele Mattiello and Luigi Mosciaro
Energies 2025, 18(13), 3348; https://doi.org/10.3390/en18133348 - 26 Jun 2025
Viewed by 220
Abstract
In the automotive industry, the increasing stringent standards to reduce fuel consumption and pollutant emissions has driven significant advancements in turbocharging systems. The centrifugal compressor, as the most widely used power-absorbing machinery, plays a crucial role but remains one of the most complex [...] Read more.
In the automotive industry, the increasing stringent standards to reduce fuel consumption and pollutant emissions has driven significant advancements in turbocharging systems. The centrifugal compressor, as the most widely used power-absorbing machinery, plays a crucial role but remains one of the most complex components to study and design. While most numerical studies rely on adiabatic models, this work analyses several Computational Fluid Dynamics (CFD) models with conjugate heat transfer (CHT) of varying complexity, incorporating real solid components. This approach allowed a sensitivity analysis of the performance obtained from the different models compared to the adiabatic case, highlighting the effects of internal heat exchange losses. Moreover, an analysis of the temperature distribution of the wheel was conducted, along with a thermal assessment of the various heat flux contributions across the different components, to gain a deeper understanding of the performance differences. The impact of including the seal plate has been evaluated and different boundary conditions on the seal plate have been tested to assess the uncertainty in the results. Finally, the influence of heat exchange between the shroud and the external environment is also examined to further refine the model’s accuracy. One of the objectives of this work is to obtain a correct temperature profile of the rotor for a subsequent thermo-mechanical analysis. Full article
Show Figures

Figure 1

40 pages, 57486 KiB  
Review
Review of Automotive Thermoelectric Generator Structure Design and Optimization for Performance Enhancement
by Yue Wang, Ruochen Wang, Ruiqian Chai, Renkai Ding, Qing Ye, Zeyu Sun, Xiangpeng Meng and Dong Sun
Processes 2025, 13(6), 1931; https://doi.org/10.3390/pr13061931 - 18 Jun 2025
Viewed by 648
Abstract
Thermoelectric generator (TEG) has emerged as a critical technology for automotive exhaust energy recovery, yet there is still a lack of reviews analyzing automotive TEG structure design and optimization methods simultaneously. Therefore, this review consolidates structure design and methods for improving thermoelectric conversion [...] Read more.
Thermoelectric generator (TEG) has emerged as a critical technology for automotive exhaust energy recovery, yet there is still a lack of reviews analyzing automotive TEG structure design and optimization methods simultaneously. Therefore, this review consolidates structure design and methods for improving thermoelectric conversion efficiency, focusing on three core components: thermoelectric module (TEM), heat exchanger (HEX), and heat sink (HSK). For TEM, research and development efforts have primarily centered on material innovation and structural optimization, with segmented, non-segmented, and multi-stage configurations emerging as the three primary structural types. HEX development spans external geometries, including plate, polygonal, and annular designs, and internal enhancements such as fin, heat pipe, metal foam, and baffle to augment heat transfer. HSK leverages active, passive, or hybrid cooling systems, with water-cooling designs prevalent in automotive TEG for cold-side thermal management. Optimization methods encompass theoretical analysis, numerical simulation, experimental testing, and hybrid methods, with strategies devised to balance computational efficiency and accuracy based on system complexity and resource availability. This review provides a systematic framework to guide the design and optimization of automotive TEG. Full article
(This article belongs to the Section Energy Systems)
Show Figures

Figure 1

26 pages, 9623 KiB  
Review
Non-Uniformities in Heat Exchangers: A Two-Decade Review of Causes, Effects, and Mitigation Strategies
by Shehryar Ishaque, Naveed Ullah, Qazi Shahzad Ali, Naveed Ullah, Sanghun Choi and Man-Hoe Kim
Energies 2025, 18(11), 2751; https://doi.org/10.3390/en18112751 - 26 May 2025
Cited by 1 | Viewed by 642
Abstract
While extensive research has focused on improving the efficiency and performance of heat exchangers (HXs), identifying the underlying causes of performance degradation remains equally important. Flow and temperature non-uniformities are among the most critical factors affecting performance, often reducing thermo-hydraulic efficiency by approximately [...] Read more.
While extensive research has focused on improving the efficiency and performance of heat exchangers (HXs), identifying the underlying causes of performance degradation remains equally important. Flow and temperature non-uniformities are among the most critical factors affecting performance, often reducing thermo-hydraulic efficiency by approximately 5–10%. These non-uniformities commonly manifest as thermal inconsistencies, airflow maldistribution, and uneven refrigerant distribution. Researchers have observed a notable performance degradation—up to 27%—due to flow maldistribution. Therefore, a clear understanding of their causes and effects is essential for developing effective mitigation strategies to enhance system performance. Despite the notable progress in this area, few studies have systematically classified the dominant non-uniformities associated with specific HX types. This article presents a two-decade review of the causes, impacts, and mitigation approaches related to non-uniformities across different HX configurations. The primary objective is to identify the most critical form of non-uniformity affecting performance in each category. This review specifically examines plate heat exchangers (PHXs), finned and tube heat exchangers (FTHXs), microchannel heat exchangers (MCHXs), and printed circuit heat exchangers (PCHXs). It also discusses mathematical models designed to account for non-uniformities in HXs. This article concludes by identifying key research gaps and outlining future directions to support the development of more reliable and energy-efficient HXs. Full article
Show Figures

Figure 1

21 pages, 2979 KiB  
Article
Analysis of Precision Regulation Pathways for Thermal Substation Supply–Demand Balance
by Jiaxiang Yin, Pengpeng Zhao and Jinda Wang
Energies 2025, 18(11), 2691; https://doi.org/10.3390/en18112691 - 22 May 2025
Viewed by 376
Abstract
Under the dual imperatives of air pollution control and energy conservation, this study proposes an enhanced optimization framework for combined heat and power (CHP) district heating systems based on bypass thermal storage (BTS). In contrast to conventional centralized tank-based approaches, this method leverages [...] Read more.
Under the dual imperatives of air pollution control and energy conservation, this study proposes an enhanced optimization framework for combined heat and power (CHP) district heating systems based on bypass thermal storage (BTS). In contrast to conventional centralized tank-based approaches, this method leverages the dynamic hydraulic characteristics of secondary network bypass pipelines to achieve direct sensible heat storage in circulating water, significantly improving system flexibility and energy efficiency. The core innovation lies in addressing the critical yet under-explored issue of control valve dynamic response, which profoundly impacts system operational stability and economic performance. A quality regulation strategy is systematically implemented to stabilize circulation flow rates through temperature modulation by establishing a supply–demand equilibrium model under bypass conditions. To overcome the limitations of traditional feedback control in handling hydraulic transients and heat transfer dynamics in the plate heat exchanger, a Model Predictive Control (MPC) framework is developed, integrating a data-driven valve impedance-opening degree correlation model. This model is rigorously validated against four flow characteristics (linear, equal percentage, quick-opening, and parabolic) and critical impedance parameters (maximum/minimum controllable impedance). This study provides theoretical foundations and technical guidance for optimizing secondary network heating systems, enhancing overall system performance and stability, and promoting energy-efficient development in the heating sector. Full article
(This article belongs to the Special Issue Advanced Research on Heat Exchangers Networks and Heat Recovery)
Show Figures

Figure 1

22 pages, 12898 KiB  
Article
Topology Optimization Design of Phase Change Liquid Cooling Composite Plate
by Xinqiang Xia, Jiancheng Luo, Jiabao Li and Lixia Wei
Energies 2025, 18(10), 2652; https://doi.org/10.3390/en18102652 - 20 May 2025
Viewed by 741
Abstract
To address the challenges of high flow resistance and poor temperature uniformity in conventional PCM–liquid cooling hybrid heat exchangers—which significantly impair the performance and lifespan of electronic devices—a topology optimization approach was adopted. A dual-objective function, aimed at minimizing the average temperature and [...] Read more.
To address the challenges of high flow resistance and poor temperature uniformity in conventional PCM–liquid cooling hybrid heat exchangers—which significantly impair the performance and lifespan of electronic devices—a topology optimization approach was adopted. A dual-objective function, aimed at minimizing the average temperature and pressure drop, was introduced to reconstruct the cooling channel layout and PCM filling region. A two-dimensional transient thermo-fluid model coupling the solid–liquid phase-change process with coolant flow and heat transfer was established, alongside the development of an experimental platform. A comprehensive comparison was performed against a conventional liquid cooling plate with straight channels. The results showed that the topology-optimized cooling plate exhibited a pressure drop of 15.80 Pa and a pumping power of 1.19 × 10⁻4 W, representing reductions of 38.28% and 38.02%, respectively. The PCM solidification time was shortened by 6 min. Under these conditions, the convective heat transfer coefficient (hw) and performance evaluation criterion (j/f) of the optimized plate reached 1319.06 W/(m2·K) and 0.56, which corresponded to increases of 60.71% and 47.5%, respectively. The topology-optimized configuration significantly improved temperature uniformity and overall cooling performance. As the inlet velocity increased from 0.05 m/s to 0.2 m/s, hw increased by 38.65%; however, j/f decreased by 57.14%, due to the limited thermal conductivity of the PCMs, resulting in only a slight reduction in the average PCM temperature. Furthermore, the topology-optimized cooling plate demonstrated stronger steady-state regulation capability under fluctuating thermal loads. This study provides valuable insights and design guidance for the development of high-efficiency hybrid liquid cooling plates. Full article
Show Figures

Figure 1

21 pages, 5567 KiB  
Article
Experimental Testing of a Heat Exchanger with Composite Material for Deep Dehumidification
by Valeria Palomba, Antonio Fotia, Fabio Costa, Davide La Rosa and Vincenza Brancato
Energies 2025, 18(10), 2418; https://doi.org/10.3390/en18102418 - 8 May 2025
Viewed by 552
Abstract
Deep dehumidification is crucial for industrial applications requiring ultra-low humidity levels. Traditional cooling-based dehumidification struggles to achieve low dew points efficiently due to excessive energy consumption and frost formation risks. As an alternative, desiccant-based methods, particularly solid desiccant systems, offer improved performance with [...] Read more.
Deep dehumidification is crucial for industrial applications requiring ultra-low humidity levels. Traditional cooling-based dehumidification struggles to achieve low dew points efficiently due to excessive energy consumption and frost formation risks. As an alternative, desiccant-based methods, particularly solid desiccant systems, offer improved performance with lower energy demands. This study experimentally investigates a fixed-bed dehumidification system utilizing a plate-fin heat exchanger filled with a silica gel/calcium chloride composite material. The performance evaluation focuses on the influence of ambient conditions and operating parameters, including air velocity and cooling fluid temperature. Among these, the most influential parameter was the velocity of air. For the tested heat exchanger, an optimum value in the range of 0.4–0.6 m/s was identified. Under optimal conditions, the tested HEX was able to reduce the dew point of air down to −2 °C, achieving a reduction in the humidity ratio up to 13 g/kg. The results indicate that air velocity significantly impacts also heat and mass transfer, with coefficients ranging from 80 to 140 W/(m2 K) and 0.015 to 0.060 kg/(m2 s), respectively. The findings highlight the potential of composite desiccant fixed-bed systems for efficient deep dehumidification, outperforming conventional lab-scale components in heat and mass transfer effectiveness. A comparison with other works in the literature indicated that up to 30% increased mass transfer coefficient was achieved and up to seven times higher heat transfer coefficient was measured. Full article
Show Figures

Figure 1

18 pages, 22994 KiB  
Article
Design of a Proton Exchange Membrane Electrolyzer
by Torsten Berning
Hydrogen 2025, 6(2), 30; https://doi.org/10.3390/hydrogen6020030 - 2 May 2025
Viewed by 2897
Abstract
A novel design of a proton exchange membrane electrolyzer is presented. In contrast to previous designs, the flow field plates are round and oriented horizontally with the feed water entering from a central hole and spreading evenly outward over the anode flow field [...] Read more.
A novel design of a proton exchange membrane electrolyzer is presented. In contrast to previous designs, the flow field plates are round and oriented horizontally with the feed water entering from a central hole and spreading evenly outward over the anode flow field in radial, interdigitated flow channels. The cathode flow field consists of a spiral channel with an outlet hole near the outside of the bipolar plate. This results in anode and cathode flow channels that run perpendicular to avoid shear stresses. The novel sealing concept requires only o-rings, which press against the electrolyte membrane and are countered by circular gaskets that are placed over the flow channels to prevent the membrane from penetrating the channels, which makes for a much more economical sealing concept compared to prior designs using custom-made gaskets. Hydrogen leaves the electrolyzer through a vertical outward pipe placed off-center on top of the electrolyzer. The electrolyzer stack is housed in a cylinder to capture the oxygen and water vapor, which is then guided into a heat exchanger section, located underneath the electrolyzer partition. The function of the heat exchanger is to preheat the incoming fresh water and condense the escape water, thus improving the efficiency. It also serves as internal phase separator in that a level sensor controls the water level and triggers a recirculation pump for the condensate, while the oxygen outlet is located above the water level and can be connected to a vacuum pump to allow for electrolyzer operation at sub-ambient pressure to further increase efficiency and/or reduce the iridium loading. Full article
Show Figures

Figure 1

24 pages, 5145 KiB  
Article
Research on Heat Transfer Coefficient Prediction of Printed Circuit Plate Heat Exchanger Based on Deep Learning
by Yi Su, Yongchen Zhao, Jingjin Wu and Ling Zhang
Appl. Sci. 2025, 15(9), 4635; https://doi.org/10.3390/app15094635 - 22 Apr 2025
Cited by 1 | Viewed by 584
Abstract
The PCHE, as an efficient heat exchanger, plays a crucial role in the storage and regasification of LNG. However, among the existing studies, those that integrate this field with deep learning are scarce. Moreover, research on explainability remains insufficient. To address these gaps, [...] Read more.
The PCHE, as an efficient heat exchanger, plays a crucial role in the storage and regasification of LNG. However, among the existing studies, those that integrate this field with deep learning are scarce. Moreover, research on explainability remains insufficient. To address these gaps, this study first constructs a dataset of heat transfer coefficients (h) through numerical simulations. Pearson correlation analysis is employed to screen out the most influential features. In terms of predictive modeling, the study compares five traditional machine learning models alongside deep learning models such as long short-term memory neural networks (LSTMs), gated recurrent units (GRUs), and Transformer. To further enhance prediction accuracy, three attention mechanisms—self-attention mechanism (SA), squeeze-and-excitation mechanism (SE), and local attention mechanism (LA)—are incorporated into the deep learning models. The experimental results demonstrate that the artificial neural network achieves the best performance among the traditional models, with a prediction accuracy for straight-path h reaching 0.891799 (R2). When comparing deep learning models augmented with attention mechanisms against the baseline models, both LSTM–SE in the linear flow channel and Transformer–LA in the hexagonal flow channel exhibit improved prediction accuracy. Notably, in predicting the heat transfer coefficient of the hexagonal channel, the determination coefficient (R2) of the Transformer–LA model reaches 0.9993, indicating excellent prediction performance. Additionally, this study introduces the SHAP interpretable analysis method to elucidate model predictions, revealing the contributions of different features to model outputs. For instance, in a straight flow channel, the hydraulic diameter (Dh) contributes most significantly to the model output, whereas in a hexagonal flow channel, wall temperature (Tinw) and heat flux (Qw) play more prominent roles. In conclusion, this study offers novel insights and methodologies for PCHE performance prediction by leveraging various machine learning and deep learning models enhanced with attention mechanisms and incorporating explainable analysis methods. These findings not only validate the efficacy of machine learning and deep learning in complex heat exchanger modeling but also provide critical theoretical support for engineering optimization. Full article
Show Figures

Figure 1

8 pages, 5715 KiB  
Proceeding Paper
Use of Cabin Sidewall for Thermal Management Applications
by Victor Norrefeldt and Gerhard Riedl
Eng. Proc. 2025, 90(1), 104; https://doi.org/10.3390/engproc2025090104 - 18 Apr 2025
Viewed by 148
Abstract
With increased electrification of new aircraft designs, cooling becomes more challenging. The most straightforward solution is to activate yet unused heat sinks available in the aircraft. The crown and cabin sidewall are such an unused area suitable for heat transfer. Here, only a [...] Read more.
With increased electrification of new aircraft designs, cooling becomes more challenging. The most straightforward solution is to activate yet unused heat sinks available in the aircraft. The crown and cabin sidewall are such an unused area suitable for heat transfer. Here, only a thin plate separates the warm cabin from the cold exterior environment in cruise. Air used for the cooling of devices could be guided along the fuselage skin to benefit from the large heat exchanging surface. Scaling test results indicate that up to 24 kW of additional heat could be dissipated in the short term through this system in flight. Full article
Show Figures

Figure 1

15 pages, 5960 KiB  
Article
Research and Application of Drilling Fluid Cooling System for Dry Hot Rock
by Kuan Li, Bing Li, Shanshan Shi, Zhenyu Wu and Hengchun Zhang
Energies 2025, 18(7), 1736; https://doi.org/10.3390/en18071736 - 31 Mar 2025
Cited by 1 | Viewed by 392
Abstract
The drilling fluid cooling system is a key technology for reducing wellbore temperatures, improving the working environment of downhole equipment, and ensuring safe and efficient drilling in high-temperature wells. Based on the existing drilling fluid cooling system, this article designs and develops a [...] Read more.
The drilling fluid cooling system is a key technology for reducing wellbore temperatures, improving the working environment of downhole equipment, and ensuring safe and efficient drilling in high-temperature wells. Based on the existing drilling fluid cooling system, this article designs and develops a closed drilling fluid cooling system according to the working environment and cooling requirements of the GH-02 dry hot rock trial production well in the Gonghe Basin, Qinghai Province. The system mainly includes a cascade cooling module, a convective heat exchange module, and a monitoring and control module. Based on the formation conditions and drilling design of the GH-02 well, a transient temperature prediction model for wellbore circulation is established to provide a basis for the design of the cooling system. Under the conditions of a drilling fluid displacement of 30 L/s and a bottomhole circulation temperature not exceeding 105 °C, the maximum allowable inlet temperature of the drilling fluid is 55.6 °C, and the outlet temperature of the drilling fluid is 69.2 °C. The heat exchange of the drilling fluid circulation is not less than 1785 kW. Considering the heat transfer efficiency and reserve coefficient, the heat transfer area of the spiral plate heat exchanger calculated using the average temperature difference method is not less than 75 m2. By applying this drilling fluid cooling system in the 3055 m~4013 m section of well GH-02, the inlet temperature is controlled at 45 °C~55 °C, and the measured bottomhole circulation temperature remains below 105 °C. After adopting the drilling fluid cooling system, the performance of the drilling fluid is stable during the drilling process, downhole tools such as the drill bits, screws, and MWD work normally, and the failure rate of the mud pump and logging instruments is significantly reduced. The drilling fluid cooling system effectively maintains the safe and efficient operation of the drilling system, which has been promoted and applied in shale oil wells in Dagang Oilfield. Full article
Show Figures

Figure 1

Back to TopTop