Abstract
Background: The subtalar joint allows complex motion of the foot relative to the leg, the analysis of which has presented a major challenge for researchers. The considerable interpatient variation in structure and function of the subtalar joint highlights the importance of developing a protocol to assess the kinematics in individuals rather than developing an overarching description of function. The use of skin-mounted markers is, therefore, preferable, allowing the noninvasive collection of data. We sought to assess the face validity of a skin-mounted marker–based protocol to measure the in vivo kinematics of the subtalar joint. Methods: Thirty participants were recruited using minimal exclusion criteria. A previously tested skin-mounted marker placement protocol was used in conjunction with two CODA MPX 30 sensors to capture data during walking. The data produced were compared with those from previous studies that used bone-mounted markers. Results: The results in all three planes represented feasible outcomes compared with those of previous studies, the data falling within the ranges published. Patterns of movement demonstrated are similar to, although not the same as, those shown by previous investigations. Conclusions: This study did not produce patterns of movement that exactly matched those of previous investigations. The results were, however, within the ranges previously published, and the patterns of movement shown were feasible. The results suggest the face validity of the method as a means of assessing the in vivo kinematics of the subtalar joint during the stance phase of gait.
It is well accepted that the subtalar joint (STJ) allows complex motion of the foot relative to the leg, and the analysis of this key function has presented a major challenge for researchers. Evidence from the literature suggests that the abnormal kinematics and kinetics of this joint are significant etiologic factors in the development of foot and lower-limb overuse injuries.[1] A critical element in the assessment of joint kinematics is the measurement of bone segment motion. With respect to the STJ, the measurement of this motion is impeded by the relatively small size of the calcaneus and talus, the inaccessibility of the talus, and the skin movement relative to the bone.[1,2,3,4] Nevertheless, the considerable interpatient variation that is known to exist in terms of the structure and function of the STJ highlights the importance of developing a method to assess STJ kinematics in individuals rather than developing an overarching description of STJ function.[5,6,7]
The use of in vivo skin-mounted marker–based three-dimensional (3-D) modeling techniques is particularly appealing in the context of interpatient variability, allowing the noninvasive collection of data from substantial numbers of patients. Few 3-D skin marker–based STJ protocols have been published in the literature.[8,9] In the Heidelberg foot measurement method described by Simon et al,[8] frontal plane STJ kinematics was represented as a projection angle between a vector from the medial malleolus to the lateral malleolus and a vector between the medial and lateral heel markers along the so-called subtalar axis. This axis was obtained using three markers on the calcaneus and one on the navicular bone together with an optimization procedure. Jenkyn and Nicol [9] adopted the method of Grood and Suntay [10] for describing STJ kinematics, defining the STJ coordinate system using vectors defined by the medial and lateral malleolus and the talar head and lateral tuberosity of the calcaneus. In both methodological papers, the authors reported consistent motion patterns.
More recently, we proposed a marker placement protocol for modeling STJ kinematics, including markers at the malleoli, calcaneus, and talar head.[11] Results of static repeatability trials showed that the model produced repeatable data. The quantification of skin marker movement at the malleoli and talar head and the associated effect on the marker placement model’s validity has also been investigated,[11] together with single-subject repeatability.[12]
The aim of this study was to assess the face validity of using the CODA MPX 30 system (Charnwood Dynamics Ltd, Leicester, England) and the previously developed skin-mounted marker placement protocol to measure the in vivo kinematics of the STJ.
Methods
Participants
Thirty participants (13 men and 17 women; age range, 18–51 years; body mass index [calculated as the weight in kilograms divided by the square of the height in meters] range, 20.7–28.1) were recruited from the staff and students of the School of Health Professions, University of Brighton (Eastbourne, England). Because the intention of this study was to assess the ease of use and face validity of the protocol with multiple participants, the exclusion criteria were kept to a minimum. In this way, a sample was produced with mixed anthropometric characteristics. The inclusion criteria for the participants were age 18 years or older, having both legs and feet, and able to walk unaided in what they consider to be a normal or usual manner several times in the movement laboratory. The following exclusion criteria were applied to potential participants: 1) a history of surgery to the hips, knees, or feet; 2) acute or chronic injury to the lower back, hips, knees, legs, or feet at the time of the study; and 3) experiencing or recovering from any illness that resulted in dizziness, breathlessness, or muscle weakness. Ethical approval was received from the ethics committee of the School of Health Professions, University of Brighton. All of the participants were provided with a subject information sheet and signed an informed consent form before the commencement of data collection.
3-D Skin Marker–Based Protocol
The marker placement model, protocol, and segmental definitions recently described by Birch and Deschamps [4,11,12] were used in this study. For clarity, a brief description is given. Fourteen markers, 8 mm in diameter and mounted in a casing approximately 20 × 10 mm, were located on the right foot and leg of each participant to define the calcaneus and talus as rigid segments (Figure 1). The markers were positioned by palpating the anatomical landmarks using a written protocol developed for the investigation by Birch and Deschamps.[4] The calcaneus was defined using four markers. The x-axis was defined by a vector drawn between the posteromedial calcaneus marker and the posterolateral calcaneus marker, and the y-axis was defined as being at a right angle to the x-axis in the direction of a virtual middle anterior marker calculated from the anteromedial calcaneus marker and the anterolateral calcaneus marker (Figure 2A). The talus was defined using the medial and lateral talus markers and a middle ankle virtual marker located midway between the medial and lateral malleolus markers (Figure 2B). The x-axis of the talus was defined as a vector drawn between the medial and lateral talus markers, and the y-axis was defined as a vector at a right angle to the x-axis in the direction of the middle malleolus virtual marker. For both bones, the mutually orthogonal z-axis was determined by the position of the x- and y-axes.
Figure 1.
Marker and driver box placement on the foot and lower limb.
Figure 2.
Definitions of the rigid segments: calcaneus (A) and talus (B). Four bony landmarks were used to construct the calcaneal and talar anatomical reference frame (following the protocol of Birch and Deschamps [4]).
Instrumentation and Measurement Protocol
Positional data were collected using two CODA MPX 30 sensor units situated at either end of a 7-m walkway. We previously tested the accuracy and repeatability of this system.[11] Estimations of the position of markers was shown to vary by less than 1 mm along all three axes (x = 0.19 mm, y = 0.72 mm, and z = 0.47 mm). Estimations of the angular orientation of defined rigid bodies produced SDs of 0.428 in the xy plane (mean = 8.97), 0.028 in the xz plane (mean = −3.89), and 0.288 in the yz plane (mean = −27.75), whereas the SDs of estimations of the orientation of one rigid body relative to another were shown to be 0.118, 0.128, and 0.228 in the frontal, sagittal, and transverse planes, respectively. The CODA was zeroed and aligned according to the manufacturer’s standard protocol, and kinematic data were collected at 200 Hz.
After placement of the markers and driver boxes, participants were instructed to walk from one end of the walkway to the other until three data sets were obtained. Each of the three data sets from each participant was viewed sequentially, and the first data set to show no anomalies, such as markers going out of view for extended periods or fluctuations in position caused by loose markers, was used. On no occasion were more than three data sets required.
Data Analysis
A low-pass filter with a cutoff frequency of 10 Hz was applied to the angular segmental data to remove noise from sources such as fluorescent lights and skin vibration, and a combination of marker linear acceleration and vector angular velocity was used to identify heel strike and toeoff.[13] The angular orientations of the talus and the calcaneus were established, and a dynamic transform was undertaken using CODA motion analysis software version 5.43 to produce a graphical representation of the movement of the calcaneus in relation to the talus. All of the data were temporally normalized using a cubic spline interpolation to produce a standard-length data set (Microsoft Excel; Microsoft Corp, Redmond, Washington).
To align the multiple-participant data and make them more easily comparable, the dynamic zeroing method used by Hamel et al [14] and Michelson et al [15] was applied. This involved identifying the point in the contact phase at which the leg was vertical to the ground, achieved by measuring the orientation of the line between the lateral malleolus marker and the fibular head marker. The angle of this line, projected in the yz plane, with respect to the z axis was then used to establish the point at which the leg reached a vertical orientation. The timing of this event was noted and later used to establish the angle of orientation of the calcaneus in relation to the talus, in each of the three planes, at the same instance in the stance phase of the gait cycle. The angular value for each plane was then subtracted from the data for that plane. In this way, the measurements produced represented the movement of the STJ in each plane about a zero or neutral value, as defined by Hamel et al [14] and Michelson et al.[15]
Results
Figure 3 shows the mean ±1 SD movement of the STJ during the stance phase of gait in the frontal, sagittal, and transverse planes. There were substantial differences in the patterns produced by the individual participants.
Figure 3.
Mean ±1 SD movement (n = 30) of the calcaneus in relation to the talus in the frontal (A), sagittal (B), and transverse (C) planes.
In the frontal plane, the data were found to be relatively closely grouped during the early part of the contact period. The waveforms then show progressive spreading of the traces, which increases noticeably close to toe-off. Similarly, the initial spread of the sagittal plane data narrows, in this case at approximately 15% of the contact phase, and then spreads progressively. Once again, the rate of spread of the data increases toward toe-off. As was the case in the frontal and the sagittal plane data, the mean ±1 SD data for the transverse plane data show an initial spread of data at heel strike, followed by tightening of the data at 10% of the contact phase. Again, the data then progressively spread toward toe-off, with final flaring in the last 10% of the contact phase.
In all three planes, the ±1 SD traces show a spread within 108 for most of the contact phase, although the sagittal plane data exceed this spread at approximately 60% of the stance phase. In view of the anticipated variations in the movement patterns likely to be occurring at the STJ of the recruited cohort,[5,6,7] Figure 3 shows relatively closely associated data in all three planes. There are clear differences among participants, but the differences are not as large as might have been expected based on the findings of previous research.[5,6,7]
Discussion
Thirty individuals were measured to assess the face validity of using the CODA and the previously developed skin-mounted marker placement model to measure the in vivo kinematics of the STJ. The measuring system and the marker placement model had previously been shown to produce reliable in vitro results [11] and repeatable in vivo results when tested on a single individual.[12] Figure 3 suggests that this method produces usable data in terms of the in vivo kinematics of the STJ. The issue of skin movement over the underlying bones, and the resulting error when using skin-mounted marker models, was considered in detail by Birch and Deschamps.[4] The x-ray–based research described in that article showed that the effect of skin movement on angular measurements was somewhat less than might have been expected (a 18 underestimation in the sagittal and transverse planes and a 58 overestimation in the frontal plane). These results were produced at end range of motion and, therefore, represent the most extreme possible outcome. It is, however, acknowledged that the composition and mechanical properties of skin are likely to vary from patient to patient, resulting in variable errors.
The normal process would be to compare the results yielded by this study with those produced by a gold standard measurement technique. However, in this case, no such gold standard technique currently exists. Arndt et al,[2] and later Nester et al,[3] used pins inserted into the bones of living patients, and this could perhaps be considered to be the closest to a gold standard for STJ kinematics that exists. Although these two papers considered only nine patients, the results showed, as might be expected in view of the findings from earlier work in the field, considerable variation between participants and, therefore, no conclusive outcome. It is difficult to know how well the in vitro method used by Hamel et al [14] and Michelson et al [15] reproduced normal walking and, therefore, how well their results might match those of an in vivo study. Nevertheless, to establish the validity of the method used, the results of this study were compared with those published by Arndt et al,[2] Hamel et al,[14] Michelson et al,[15] and Nester et al.[3] Although Figure 4 shows the results published by all four previous studies, those by Hamel et al [14] and Michelson et al [15] might be considered to provide the most appropriate comparison data. These two studies (in fact, the same data) showed the averaged data of the eight specimens rather than the traces produced by individuals, as was the case in the study by Arndt et al.[2] The strategy of considering the summarized data produced by participant groups rather than those produced by single participants was adopted in line with previous researchers. In fact, we consider the most important facet of this area of kinesiology to be the intrasubject and intersubject variability of movement, a view that we believe is slowly being recognized by other workers. If this approach is taken, the use of arithmetic means and their derivatives to summarize group data is wholly inappropriate. Variability in the range, timing, and possibly even direction of movements of foot segments between the individual steps of a single patient and between those of multiple patients would produce spurious mean values. Nevertheless, the use of summarized data is a strategy that has been used by previous workers in this field and has, therefore, been used in this study to allow comparison with previous findings.
Figure 4.
Motion of the subtalar joint during the contact phase of walking as shown by this and previous studies in the frontal (A), sagittal (B), and transverse (C) planes.
Figure 4A shows the frontal plane movement. Heel strike is followed by a period of gradual inversion lasting until approximately 30% of the stance phase. The STJ then progressively everts until 95% of stance, when it again inverts until toeoff. This pattern of movement seems to reflect that found by Birch and Deschamps [12] based on a single patient and bears some resemblance to the pattern of movement shown by Michelson et al [15] and Hamel et al [14] in multiple-specimen data and Arndt et al [2] subject 3 data. The data are similar, although inverse, to those of Arndt et al [2] subjects 1 and 2 and Nester et al [3] average of six individuals. The patterns of movement are not the same, but none of the work to date has produced exact replications of measured STJ movement. The movement shown in the frontal plane by the method under investigation in this study seems to produce results that are entirely feasible and within the range of those produced by other investigators.
Figure 4B shows the sagittal plane movement. Heel strike is followed by dorsiflexion of the STJ until approximately 25% of the stance phase, after which there is a period of stability until 50% of the stance phase, at which point the joint begins to plantarflex. Plantarflexion continues until 70% of the stance phase, after which dorsiflexion occurs until toe-off. Again, the sagittal plane data, in terms of the pattern of movement, show some resemblance to those of Birch and Deschamps [12] and those of the earlier papers using bone-mounted markers. As was the case with the frontal plane data, the pattern of sagittal plane STJ movement shown by the multiplesubject mean trace compared with that of other researchers seems to be a feasible outcome.
Figure 4C shows the transverse plane motion of the STJ. Heel strike is shown to be followed by very slight abduction before slight adduction lasting until 15% of the stance phase. Slight abduction then occurs until 35%, slight adduction until 50%, then abduction once more until 65%, followed by slight adduction until 90%, and finally more rapid abduction until toe-off. The trace shows a close resemblance to that found by Michelson et al [15] and Hamel et al,[14] although reduced in total range, and that of subject 3 in the study by Arndt et al,[2] except for the last 10%. As was the case in the frontal plane, the data are similar, although inverse, to those of Arndt et al [2] subjects 1 and 2 and Nester et al [3] average of six individuals. Once again, the transverse plane results are such that they represent an entirely feasible outcome from the measurement protocol under investigation.
The convergence of the ±1 SD lines in Figure 3 at 10% to 15% looks at first glance to be evidence in support of a theory embracing the notion of a changing degree of stability in the STJ. It occurs at the time in the contact phase when the joint is likely to be under its greatest loading, as the mass of the body is decelerated. However, it is much more likely that it represents a mathematical anomaly caused by the combination of the neutral position being established using the timing of the leg being perpendicular to the ground and the process of temporal normalization.
The results in all three planes represent feasible outcomes compared with those of previous researchers. The patterns of movement demonstrated are similar to, although not the same as, those shown by previous investigations.
Conclusions
In the case of most aspects of human movement, the history of measurement has started with diverse results and then, as the measurement techniques and technology have improved, the variations have resolved, producing a clear understanding of the movement. In the case of the STJ, the opposite has been the case. Early workers believed that they had generated enough evidence to show that there was a simple and clear pattern of movement occurring at the STJ during the stance phase of walking as the result of a well-understood joint function. As research into the STJ has progressed, particularly in the past 10 years, investigations into STJ movement have not produced a uniform outcome. The mode of action of the STJ, once thought to be a simple hinge, is now more often thought of as a more complex kinematic relationship between the talus and calcaneus, allowing 6 df.[16,17] The pattern of movement of the joint, confidently described in the textbooks of the 1970s and 1980s, has been shown by more recent studies to be greatly variable.
The combination of high-resolution 3-D kinematic analysis techniques and in vivo intracortical pin insertion should be regarded as being as close to a gold standard approach to STJ kinematic assessment as is currently possible. There is certainly no reason to suspect that this technique has produced erroneous data. The studies by Arndt et al [2] and Nester et al,[3] therefore, stand out as producing the most valuable data to date. With a total of only nine participants, the results varied. One of the weaknesses of research in this field is that no single technique has been used on a substantial number of patients, largely for ethical reasons. In the absence of a large body of data, and in the absence of any particular reason to doubt the outcomes of the published papers, the research to date suggests that the kinematics of the STJ is greatly variable between individuals. The development of a noninvasive in vivo measurement strategy to underpin clinical practice is, therefore, all the more important. This study did not produce patterns of movement that exactly matched those of any other investigations. The results of this study were within the ranges of results of the other studies, and the patterns of movement shown were feasible.
We recognize that the work reported in this article, a test of face validity, represents only one stage of the development of a noninvasive in vivo method of assessing the kinematics of the STJ. The fact that the results produced, when represented in the same way as those of previous investigators, fit within the envelope of those produced by those investigators suggests the face validity of the method as a means of assessing the in vivo kinematics of the STJ during the stance phase of gait.
Funding
None reported.
Conflicts of Interest
None reported.
References
- LEWIS GS, COHEN TL, SEISLER AR, ET AL: In vivo tests of an improved method for functional location of the subtalar joint axis. J Biomech 19: 146, 2009.
- ARNDT A, WESTBLAD P, WINSON I, ET AL: Ankle and subtalar joint kinematics measured with intercortical pins during the stance phase of walking. Foot Ankle Int 25: 357, 2004.
- NESTER C, JONES RK, LIU A, ET AL: Foot kinematics during walking measured using bone and surface mounted markers. J Biomech 40: 3412, 2007.
- BIRCH I, DESCHAMPS K: Quantification of skin marker movement at the malleoli and talar heads. JAPMA 101: 497, 2011.
- MANTER, J.T. Movements of the subtalar and transverse tarsal joints. Anat Rec 1941, 80, 397. [Google Scholar] [CrossRef] [Scilit]
- ROOT ML, WEED JH, SGARLATO TE, ET AL: Axis of motion of the subtalar joint. JAPA 56: 149, 1966.
- VAN LANGELAAN EJA: A kinematic analysis of the tarsal joints. Acta Orthop Scand Suppl 204: 1, 1983.
- SIMON J, DOEDERLEIN L, MCINTOSH AS, ET AL: The Heidelberg foot measurement method: development, description and assessment. Gait Posture 23: 411, 2006.
- JENKYN, T.R.; NICOL, A.C. A multi-segment kinematic model of the foot with a novel definition of forefoot motion for use in clinical gait analysis during walking. J Biomech 2007, 40, 3271. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- GROOD, E.S.; SUNTAY, W.J. A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. J Biomech Eng 1983, 105, 136. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- BIRCH, I.; DESCHAMPS, K. The in vitro reliability of the CODA MPX30 as the basis for a method of assessing the in vivo motion of the subtalar joint. JAPMA 2011, 101, 400. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- BIRCH, I.; DESCHAMPS, K. Noninvasive quantification of subtalar joint kinematics: a pilot investigation. JAPMA 2012, 104, 103. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- JASIEWICZ JM, ALLUM JHJ, MIDDLETON JW, ET AL: Gait event detection using linear accelerometers or angular velocity transducers in able-bodied and spinal-cord injured individuals. Gait Posture 24: 502, 2006.
- HAMEL AJ, SHARKEY NA, BUCZEK FL, ET AL: Relative motions of the tibia, talus and calcaneus during the stance phase of gait: a cadaver study. Gait Posture 20: 147, 2004.
- MICHELSON J, HAMEL A, BUCZEK F, ET AL: The effect of ankle injury on subtalar joint motion. Foot Ankle Intern 25: 639, 2004.
- YING N, KIM W, WONG Y, ET AL: Analysis of passive motion characteristics of the ankle joint complex using dual Euler angle parameters. Clin Biomech 19: 153, 2004.
- DE ASLA RJ, WAN L, RUBASH HE, ET AL: Six DOF in vivo kinematics of the ankle joint complex: application of a combined dual-orthogonal fluoroscopic and magnetic resonance imaging technique. J Orthop Res 24: 1019, 2006.
© 2014 American Podiatric Medical Association