Abstract
Standoff optical detection of explosives must meet multiple operational requirements simultaneously. This review formalizes seven quantitative operational requirements, derived from blast safety doctrine, forensic contamination data, published standards, and detection theory, each evaluated using an explicit scoring criterion: standoff distance, trace sensitivity, false alarm rate, acquisition speed, selectivity, environmental operating envelope, and moving-target capability. Guided by PRISMA 2020, the review evaluates the 2020–2026 literature on hyperspectral imaging (HSI) together with four active spectroscopies as a comparative baseline: Raman, terahertz, laser-induced breakdown, and laser-induced fluorescence. Assessed against this requirements-based framework, none of the active spectroscopies satisfies all seven requirements, reflecting predominantly point-wise, laboratory-bound architectures. HSI provides the imaging architecture largely absent from these techniques, but neither the passive nor the active branch satisfies all seven requirements. Passive HSI provides standoff imaging from weak overtone bands but no demonstrated trace sensitivity, whereas active HSI accesses the fundamental long-wave infrared fingerprint bands and reports tested or estimated trace-level loadings only over a few metres, without an established detection limit. Standoff distance and sensitivity are rarely measured together, limiting assessment of operational performance. Deployment is constrained not only by sensing physics but also by the lack of standardized performance evidence, public benchmark datasets, and operational validation.
1. Introduction
Standoff optical detection of explosives is among the most operationally demanding sensing problems in the analytical sciences. The threat appears in trace amounts on substrates the operator cannot prepare, in environments the operator cannot control, against a background of benign chemicals that mimic its spectral features, and on a clock that the deployment scenario sets. The sensor must report on it from a distance that keeps the operator clear of the blast envelope, with a selectivity that the cost of a false alarm requires, and at a throughput that vehicle, pedestrian or aerial traffic demands. This review evaluates the optical detection methods published between 2020 and 2026 against these operational constraints, with particular emphasis on hyperspectral imaging (HSI). Among the architectures reviewed here, HSI is the only one that encodes both spatial and spectral information in a data cube, acquired either sequentially or in a snapshot, while offering a passive route. This review examines the operational performance implications of this distinct measurement architecture. The surveyed literature predominantly divides HSI into a passive visible-to-short-wave infrared branch and an actively illuminated long-wave infrared branch, both of which are evaluated separately throughout this review.
The remainder of Section 1 establishes the operational problem and the constraints that it imposes (Section 1.1) then states the scope and contributions of the review (Section 1.2). Section 2 specifies the literature collation methodology, guided by the PRISMA 2020 reporting framework, and formalizes the seven operational requirements against which the experimental results in this review are scored. Section 3 summarizes the four active spectroscopies used as a comparative baseline, namely Raman scattering, terahertz sensing, laser-induced breakdown spectroscopy and laser-induced fluorescence and shows why none of them reaches an imaging architecture. Section 4 examines hyperspectral imaging itself: its measurement physics, sensor architectures, spectral fingerprints and processing chain, and the performance its experimental studies have reached on each of the seven axes. Section 5 sets out the open challenges and the research directions they define. Section 6 summarizes the findings and states the conclusions.
1.1. Operational Problem and Field Constraints
The improvised explosive device (IED) is the dominant kinetic threat to deployed forces, civilian infrastructure and humanitarian clearance operations in the post-2010 security landscape, a threat given renewed urgency by large-scale mine and unexploded ordnance contamination, notably that of the war in Ukraine, and the corresponding detection literature has expanded rapidly across optical, chemical and biological techniques [1,2,3]. The analytical problem is twofold: bulk detection involves concealed masses ranging from hundreds of grams to tens of kilograms, whereas trace detection seeks the chemical residues that the device, its precursors, or its handlers leave on surrounding surfaces, typically at microgram per square centimetre levels. Trace detection spans two distinct operating contexts. The forensic context is served by laboratory techniques such as gas chromatography–mass spectrometry (GC–MS) and liquid chromatography–mass spectrometry (LC–MS), which analyze prepared swab samples over timescales of minutes to hours [4]. The operational context, which is the focus of this review, aims to detect those chemical residues in situ, at standoff, against cluttered and unprepared backgrounds, and within seconds [2]. A residue is not itself the hazard. It indicates that the person, vehicle or object carrying it has been in contact with a charge, which may be present. The standoff distance required in this context is therefore set by that charge, through safety doctrine. Protective standoff distances for body-worn improvised explosive devices extend to several tens of metres, whereas those for large vehicle-borne charges can exceed 100 m [5]. Consequently, checkpoint inspections are conducted from blast- and ballistically protected positions at the maximum practical range [6,7]. A sensor that operates only at a one-metre standoff therefore does not address the operational problem, regardless of its sensitivity at that distance; sufficient standoff must be achieved before sensitivity becomes operationally meaningful.
Throughout this review, ultraviolet (UV) denotes 0.2–0.4 m, visible (VIS) is 0.4–0.7 m, near-infrared (NIR) is 0.7–1.0 m, visible and near-infrared together form visible–near-infrared (VNIR) at 0.4–1.0 m, short-wave infrared (SWIR) is 1.0–2.5 m, mid-wave infrared (MWIR) is 3–5 m, and long-wave infrared (LWIR) is 6–14 m. The intervals omitted between these bands are dominated by atmospheric absorption. UV is reached only by the active spectroscopies of Section 3. The LWIR range is adopted here to encompass molecular fingerprint absorptions and to maintain consistency with the quantum cascade laser instruments reviewed in Section 4, several of which operate from 6 m. Within this range, the 6–8 m region is strongly attenuated by atmospheric absorption. Conventions vary across the literature, and band ranges are quoted from each source’s actual wavelengths rather than its label. The illumination architecture divides optical sensing techniques into two fundamental families that directly reflect the principal deployment trade: active systems generate their own illumination, whereas passive systems rely on naturally available radiation.
Active techniques comprise laser-based methods, including Raman spectroscopy, laser-induced breakdown spectroscopy (LIBS) and laser-induced fluorescence (LIF), together with terahertz sensing and quantum cascade lasers employed for MWIR and LWIR backscatter measurements. By actively interrogating molecular and electronic transitions, these approaches exploit the chemical specificity available in spectroscopic fingerprint regions. However, this performance is constrained by eye safety limits, potential sample alteration or ignition and signal-to-noise requirements, which collectively restrict the achievable dwell time, defined here as the time available to record the full spectrum of one ground sample, at standoff distances [1,8].
Passive techniques inherit ambient radiance instead: reflected solar illumination in the VNIR and SWIR, and thermal self-emission in the MWIR and LWIR. They avoid the illumination-related dwell-time and eye safety constraints of active systems, although their performance remains limited by per-pixel signal-to-noise ratio, spectral resolution, solar geometry, atmospheric transmittance and thermal contrast [3,8]. Recovering surface reflectance from a passive scene therefore depends on atmospheric correction, whose recent acceleration toward near-real-time retrieval makes per-scene compensation tractable [9].
The two families trade range against sensitivity in opposite directions. The question this review addresses is whether the architectural advantages of HSI, namely scene-wide spatial mapping, simultaneous acquisition of a spectrum at every pixel, and a passive route, can preserve enough of the chemical specificity that the active techniques demonstrate under laboratory conditions to support a deployable trace detector that meets the standoff, acquisition speed, and moving target requirements of Section 2.2.
Field deployment imposes seven requirements, which Section 2.2 turns into numerical thresholds: (1) standoff distance, fixed by blast safety doctrine; (2) trace sensitivity, because a handled device leaves only secondary-transfer residue on the surfaces it touches; (3) a low false alarm rate, because frequent false alarms destroy operator trust at realistic inspection volumes; (4) an acquisition speed matched to the flow of pedestrians and vehicles through a checkpoint; (5) selectivity, because a checkpoint is full of benign materials such as nitrate fertilizers, carbohydrates, urea and household acids that must not raise an alarm; (6) an environmental operating envelope spanning field temperature and humidity extremes; and (7) the capability to inspect a moving target, which no reviewed study yet demonstrates.
Detection probability () and false alarm rate (FAR) cannot be evaluated independently. Because a field-deployed detector must perform a binary hypothesis test against a noisy, dynamic background, its decision logic is governed by the Neyman–Pearson criterion [10]. Under this framework, the two rates are bound to a single operating point determined by the chosen decision threshold. Consequently, a standalone claim of high detection probability is incomplete unless it is anchored to the false alarm rate obtained under the same conditions. The operating point adopted in this review is quantified in Section 2.2.
1.2. Scope and Contributions
This review establishes a seven-axis operational framework for evaluating optical architectures for standoff explosive detection, uses it to identify the limitations that currently keep the active optical spectroscopies from field deployment, and asks whether hyperspectral imaging can overcome them. The central subject is hyperspectral imaging across the VIS, NIR, SWIR, MWIR and LWIR. The four active spectroscopies, Raman and its variants, terahertz spectroscopy, laser-induced breakdown spectroscopy and laser-induced fluorescence, are treated in Section 3 as the comparative baseline against which the imaging architecture is judged. Excluded from scope are contact methods (ion mobility, mass spectrometry, microfluidic biosensors), buried-target detection by ground-penetrating radar, bulk-concealed detection by X-ray and millimeter-wave imaging, animal-assisted detection (canines, rats and honeybees), and assays that do not include a standoff optical path. The analytes in scope are intact (bulk) compounds, residues, precursors and post-blast products of the military explosives (TNT, RDX, HMX, PETN, PYX, 2,4-DNT, C-4), the inorganic energetic materials (ammonium nitrate, potassium chlorate, potassium perchlorate and black powder) and the principal peroxide-based homemade explosives (TATP and HMTD). Although peroxide explosives are included because of their operational relevance, the reviewed literature provides substantially less evidence for this class than for nitro- and nitrate-based explosives. Bulk-level identification of TATP and HMTD based on SWIR overtone features has been reported [11], whereas trace-level detection by hyperspectral imaging has not been demonstrated. Consequently, peroxide explosives are treated in this review as an important unresolved gap rather than as a demonstrated strength of current HSI approaches.
The review makes four main contributions.
- (i)
- A PRISMA 2020-informed corpus. We specify the eligibility criteria, information sources, search strategy and selection process [12], and document the resulting 2020–2026 corpus of 91 included records (Section 2.1).
- (ii)
- An operationally derived requirement framework. We formalize seven performance requirements grounded in operational need rather than current sensor capability, and mark each value in the table of Section 2.2 as derived, adapted or adopted.
- (iii)
- A requirements-based evaluation of the hyperspectral literature. We outline the spectroscopic, instrumental and computational basis of the technique, then score the experimental HSI studies against the seven requirements. This analysis exposes a central design tension: the passive branch meets the standoff requirement on bulk deposits but not the trace requirement, whereas the active branch reports tested or estimated loadings below the trace floor only within a few meters of the target, without a detection limit (Section 4).
- (iv)
- A gap diagnosis and a research agenda. We set out the open challenges, from the physics of the measurement to the architecture of the deployed instrument, and discuss long-wave infrared hyperspectral imaging, which remains underexplored, as a promising direction toward a deployable trace detector (Section 5).
2. Methodology and Operational Framework
This section sets out the two methodological commitments that govern every assessment in this review: (1) a PRISMA 2020-informed literature corpus, which determines what evidence is admitted and how it was gathered (Section 2.1); and (2) an operationally derived threshold framework, which sets the criteria by which that evidence is judged (Section 2.2). Together they make the review’s conclusions reproducible and place its techniques on a common footing.
2.1. Literature Corpus (PRISMA 2020-Informed)
The literature corpus underlying this review was collated following the PRISMA 2020 reporting framework for transparency in search and selection [12]. The review is a narrative-integrative synthesis of the 2020–2026 optical standoff explosive detection literature. Strict PRISMA 2020 compliance is not claimed: the framework was adopted for guidance. Quantitative meta-analytic procedures are not applied, since the heterogeneity of analytes, substrates, illumination configurations and reporting conventions in the corpus does not support pooled effect estimation.
Eligibility criteria. Records were eligible for inclusion if they met six criteria. They had to (i) address an explosive analyte or class of analytes, whether intact, residue, precursor or post-blast; (ii) employ an optical sensing technique between the ultraviolet and the long-wave infrared; (iii) be standoff in geometry, meaning a sensor-to-target separation greater than 10 cm in intent, including the proximal-to-standoff transitional regime that the reviewed lab-bench demonstrations occupy; (iv) appear in a peer-reviewed journal or edited volume; (v) be published between 1 January 2020 and 31 May 2026; and (vi) be written in English.
Exclusion criteria. Records were excluded if they (i) operated at a sensor-to-target separation below 10 cm or required physical contact with the target or the application of any material to it. This covers the contact analytical methods (ion mobility spectrometry, mass spectrometry, electrochemical biosensors, microfluidic assays) as well as any optical measurement whose reported figure of merit depends on swabbing, drop-casting or spraying a reagent or a metallic colloid onto the residue. Such preparation steps require direct physical contact, defeating the purpose of standoff detection; (ii) described buried-target detection by ground-penetrating radar, metal-induction or magnetic gradient sensing; (iii) described bulk-concealed detection by transmission X-ray or millimeter-wave imaging; (iv) were animal-assisted (canine, rat, honeybee); (v) were laboratory-only micro-Raman or FT-IR assays without a stated standoff geometry; (vi) were editorial, news or letter-to-editor content; (vii) addressed a non-explosive analyte that was claimed without re-validation to transfer to explosives; or (viii) appeared only as conference proceedings rather than as a peer-reviewed journal article or edited volume chapter. Studies of surrogate analytes, bulk deposits or intact ordnance, and indirect responses such as vegetation stress are retained because they supply the longest range standoff and the only moving-platform evidence in the passive branch, and Section 4.5 weighs them accordingly without counting them as trace detection evidence.
The proceedings exclusion is a deliberate quality-control choice that holds the corpus to a single peer-review standard and avoids double-counting preliminary results later superseded by or duplicated in journal articles, at a modest and acknowledged cost in breadth.
Status of pre-2020 references. The 91-paper corpus of empirical performance evidence is strictly in the 2020–2026 window. Pre-2020 references appear elsewhere in the manuscript for three specific purposes and are not substituted for in-window empirical evidence. First, doctrinal and standard-setting sources (U.S. Army field manuals, NATO standards, MIL-STD-810H, IUPAC Recommendations) are cited at their date of issue, because they are normative texts whose authority does not lapse. Second, foundational scientific references are cited at their original publication because their content has not been superseded in the window: detection theory [10], the NIST quantitative microscopy of explosive fingerprints that quantifies the trace requirement [13,14], and the human-factors work on cry-wolf and trust in automation [15,16]. Third, methodology papers that defined a specific sensing technique are cited for attribution. Every numerical performance figure carried into the Section 3 and Section 4 tables comes from an in-window record.
Information sources. Three bibliographic databases were searched: Web of Science Core Collection, Scopus (Elsevier) and IEEE Xplore. Web of Science and Scopus were chosen as the principal multidisciplinary indexes, jointly covering the peer-reviewed chemistry, remote sensing and analytical literature, with IEEE Xplore added for sensing and signal processing coverage. AI-assisted discovery tools were excluded as primary sources, so that the search rests on query strings that can be reported and re-run in full. The final database search was conducted in May 2026. Backward (reference list) and forward (citing article) citation searches were performed in Google Scholar for the records identified as core HSI–explosive papers.
Search strategy. The Boolean strategy combined three concept blocks, namely standoff geometry, explosive analyte and optical technique. The blocks were joined by AND; the synonym list within each block was joined by OR. The Web of Science query served as the canonical strategy:
TS=((standoff OR stand-off OR remote OR “distance detection”)) AND TS=(( explosive* OR “energetic material*” OR TNT OR RDX OR PETN OR HMX OR “ammonium nitrate” OR TATP OR landmine OR IED OR UXO)) AND TS=((“hyperspectral imag*” OR Raman OR LIBS OR “laser-induced breakdown” OR fluorescence OR LIF OR “photolumines*” OR terahertz OR THz OR “mid-infrared” OR “long-wave infrared” OR LWIR OR “quantum cascade” OR “dual-comb”))
The strategy was adapted to the field-tag conventions of Scopus (TITLE-ABS-KEY) and IEEE Xplore (“Document Title” OR “Abstract” OR “Index Terms”), with the three blocks and their terms kept verbatim. The Scopus query was:
TITLE-ABS-KEY((standoff OR “stand-off” OR remote OR “distance detection”) AND (explosive* OR “energetic material*” OR TNT OR RDX OR PETN OR HMX OR “ammonium nitrate” OR TATP OR landmine OR IED OR UXO) AND (“hyperspectral imag*” OR Raman OR LIBS OR “laser-induced breakdown” OR fluorescence OR LIF OR photolumines* OR terahertz OR THz OR “mid-infrared” OR “long-wave infrared” OR LWIR OR “quantum cascade” OR “dual-comb”)) AND PUBYEAR > 2019 AND LANGUAGE(English)
In IEEE Xplore Advanced Search the same three blocks were entered, each applied to the three fields. Date filters were restricted to 2020–2026; the language filter was to English. No publication-type filter beyond peer review was applied.
Selection process. All retrieved records were screened on title and abstract. Where inclusion was ambiguous, the full text was retrieved and a structured extraction (analyte, substrate, standoff distance, illumination, performance figure, decision method) was performed to resolve the ambiguity; ambiguous cases falling outside the eligibility window were excluded. No automation tools were used to make inclusion or exclusion decisions, although natural-language search-term refinement was assisted by keyword co-occurrence analysis of the initial retrieved set. The eligibility criteria and search strategy were defined by A.D. and O.O. Title-and-abstract screening, full-text assessment and data extraction were performed by A.D., with inclusion decisions reviewed with O.O. and settled by discussion. No validated risk-of-bias instrument exists for instrument-performance studies. Quality assessment examined whether studies reported the analyte, substrate, standoff distance, illumination configuration, decision method, and performance metric, with missing information recorded as “not reported”.
Corpus composition. The corpus of 91 records (Figure 1) divides into three groups: 25 empirical HSI studies forming the evidence base, 26 active spectroscopy studies forming the comparative baseline, and 40 supporting sources, HSI methodology and sensing studies, that establish instrument and processing practice. The 91 records are a subset of the 119-entry reference list; the remaining 28 entries are foundational, doctrinal and manufacturer sources cited for attribution only.
Figure 1.
PRISMA 2020 flow of records through identification, screening and inclusion for the 2020–2026 corpus (). Database records (Web of Science, Scopus, IEEE Xplore; final search May 2026) pass through deduplication, title-and-abstract screening and full-text eligibility assessment against the criteria of Section 2.1; the methodological supporting sources entered via the other-methods stream (citation searching, hand-searched reference lists, organisational sources).
Topical landscape of the corpus. Figure 2 visualizes the topical landscape of the corpus as a VOSviewer (version 1.6.20) [17] keyword co-occurrence network from the author-keyword metadata. The resulting clusters are organized by sensing technique and by processing method, consistent with the structure adopted in this review.
Figure 2.
Keyword co-occurrence network of the corpus. Node area scales with keyword occurrence and edge thickness with association strength; colour encodes the modularity cluster. Shown as a corpus-landscape aid, not as inferential evidence.
2.2. Operational Thresholds for Field Deployment
Translating “field-deployable detection” into measurable requirements demands explicit numerical thresholds derived from operational doctrine, empirical contamination data and environmental standards. A requirement space shaped by sensor convenience would codify current limitations and could not measure progress. Table 1 collects the seven requirements. For three of them, standoff distance, trace areal concentration and acquisition speed, the derived value is paired with a scoring floor, the least demanding value at which a result still has operational utility. The floors are necessary because no reviewed result reaches the derived values, so scoring against those alone would discriminate nothing. The requirement is therefore relaxed to the floor where one is defined, with the derived value retained as the target. The three floors, the detection probability, the false alarm rate and the cold bound of the environmental operating envelope are adopted by this review. The provenance column of Table 1 marks each of these six values accordingly.
Table 1.
Operational requirements and adopted evaluation criteria, including the scoring floors, for standoff explosive detection. Where a row gives two values, the first is the derived requirement, the performance targeted for deployment, and the second is the scoring floor, against which the reviewed results are scored (Section 2.2). Provenance marks each value as derived (fixed by an external source), adapted (narrowed from a standard) or adopted (chosen by this review).
Throughout this review, three types of values are distinguished: (i) an operational requirement, the performance targeted for deployment, derived from operational or safety doctrine, contamination data, or an applicable standard; (ii) an adopted evaluation criterion, chosen by this review, such as a scoring floor; and (iii) an experimentally established detection limit, defined as the value on a given threshold beyond which a source showed that detection is no longer achieved under a specified decision rule.
Reported sensitivities are not always detection limits, because many studies do not report one, and comparing them as if they represent the same performance metric would be misleading. Each reported value is therefore classified into one of three categories, as identified in the tables of Section 3.5 and Section 4.5: (i) a detection limit, as defined above; (ii) the lowest tested loading, corresponding to the smallest areal concentration that the study tested and measured; or (iii) an estimate, a value inferred by the source rather than measured directly, for example from a tested loading through the pixel footprint, regardless of its unit.
The scoring rule follows directly from these distinctions. To ensure a fair comparison, a requirement is considered satisfied only when a reported value expressed in the same quantity and unit meets the corresponding criterion, which is the scoring floor where one is defined. A lowest tested loading or an estimate below the floor provides indicative, rather than conclusive, evidence of compliance. Results reported in incompatible units are retained in these tables for completeness, identified by their unit or labelled non-comparable, but are not used to assess compliance.
The experimental conditions associated with each reported value, including substrate, standoff distance, illumination and decision method, are documented in Section 4.5. This approach preserves a common comparison framework while explicitly accounting for differences between experiments, rather than treating their results as directly interchangeable or averaging them.
The coupling between detection probability and false alarm rate deserves explicit treatment because it is what makes the field-deployable detection problem fundamentally hard. Each inspection reduces to a binary decision between threat and no threat, and two errors are possible. A false alarm (false positive) reports a benign subject as a threat, one carrying no energetic material but only an interferent such as a nitrate fertilizer, urea or a carbohydrate. A miss (false negative) passes a genuine explosive as safe. The false alarm rate is the per-inspection probability of a false alarm, and the detection probability is the probability of correctly declaring a threat when one is present, reported as recall in the machine learning studies of Section 4. This review distinguishes detection, identification, and classification. Detection is the binary threat decision, evaluated through an operating point characterised by and FAR. Identification assigns a detected material to a compound in a reference library, and classification assigns a sample to one of a fixed set of known classes. Classification accuracy therefore does not establish a false alarm rate against materials outside the defined class set. Accuracies are consequently reported as stated in the source studies, and the false alarm and selectivity thresholds in Table 1 are applied only to reported detection statistics. This review requires a detection probability of at least 0.90 together with a false alarm rate below per inspection, and no cited standard fixes either value.
The second figure is particularly demanding because genuine threats are rare, so an alarm is useful only if false alarms are rarer still. Consider a checkpoint screening 1000 people per day, with an average of one genuine threat per day. Over ten days (10,000 inspections and ten threats), a false alarm rate of produces about one false alarm alongside nine true detections at , so nine of ten alarms are genuine. At , about ten false alarms accompany the nine detections and the genuine fraction falls to about 47%, and beyond that point false alarms dominate. Operators who repeatedly find nothing behind an alarm learn to discount it, a cry-wolf effect that produces alarm fatigue and undermines the credibility of the detector regardless of its detection probability [15,16].
For prevalence p, detection probability (recall) and false alarm rate FAR (equivalently the false positive rate), the probability that an alarm corresponds to a genuine threat is the positive predictive value (PPV, or precision): . This relationship shows that alarm credibility depends not only on detector performance but also on threat prevalence. For the illustrative scenario considered above, with a prevalence of , a false alarm rate of per inspection yields approximately one false alarm for every nine true detections at , and this balance motivates the adopted criterion.
At lower threat prevalences, maintaining the same alarm credibility would require a correspondingly lower false alarm rate. For instance, at a prevalence of one threat per 100,000 inspections, maintaining approximately the same alarm credibility would require a false alarm rate of about per inspection. The rate is defined per inspection, so a rate per pixel or per window must be converted to the inspection level, accounting for the number of decision units and their dependence, before comparison. This is why the window-level figure in Section 4.5 is not assessed against the per-inspection criterion.
Together, the detection probability and the false alarm rate determine the degree of separation required between the target and background distributions. Under the equal-variance Gaussian signal-detection model, this separation is quantified by the detectability index . For the illustrative operating point used here ( and per inspection), the required separation is [10], where is the inverse cumulative distribution function of the standard normal distribution. Because real operational backgrounds are rarely Gaussian and often violate the equal-variance assumption, this value should be interpreted as an idealized best-case lower bound rather than as a universal performance threshold.
A further condition concerns evidence rather than physics. Under the explosives detection system (EDS) test-and-evaluation framework, a claimed detection probability is meaningful only when demonstrated at a stated confidence level and sample size against a documented panel of non-hazardous interfering materials (benign confusants) [24].
The standoff and trace-concentration thresholds serve different purposes in this review and should not be interpreted in the same way. The operational standoff requirement is derived from published blast safety guidance, whereas the trace-concentration requirement is derived from measurements of explosive residue transfer. For scoring, each is paired with an adopted evaluation criterion (Table 1).
The standoff requirement is derived from the least demanding of three published safety distances: the 33.5 m building-evacuation distance of the joint U.S. Department of Homeland Security and Department of Justice (DHS–DOJ) bomb-threat guidance for a person-borne device [18], the 85 m low-fatality contour for the same device [19], and the protective distances exceeding 100 m for vehicle-borne charges [5]. The 10 m value used in scoring is not a safety distance, since it lies inside the 8–18 m blast injury thresholds [20], but an adopted evaluation criterion representing the transition from laboratory-scale geometries to field-relevant optical paths. Below this distance, results provide limited information about operational range scaling.
The trace requirement is derived from the highest residue loading reported in the NIST quantitative microscopy of fresh Composition C-4 fingerprints on a smooth substrate, approximately 0.3 g cm−2 [14]. This value should not be interpreted as a universal concentration for all explosives or operational environments. Residue transfer depends on explosive composition, surface properties, transfer history and environmental exposure. Measured loadings may decrease following repeated contact [14,27] or weathering, while environmental backgrounds may further complicate trace-residue detection because common background species are ubiquitous [21]. The value is therefore used as an empirical reference rather than a universal operational threshold. Compliance assessment instead relies on the adopted scoring floor of 10 g cm−2, more than an order of magnitude above the 0.3 g cm−2 value, ensuring that comparisons do not depend on a single deposition scenario.
The acquisition requirement follows checkpoint kinematics. The dwell time per ground sample is the ground sample distance divided by the target speed [7,22]. At a representative ground sample distance of 1 cm, a post-chicane vehicle at 5 to 10 km h−1 opens a window of 7.2 to 3.6 ms, and the fastest case sets the binding requirement at 3.6 ms. A 10 ms scoring floor is adopted and corresponds to a pedestrian advancing through a checkpoint queue at about 1 m s−1. Because different hyperspectral architectures acquire spatial and spectral information differently, acquisition speed cannot be compared using a single metric such as frame rate or cube acquisition time. Each measurement must first be converted to the time required to acquire the full spectrum of one ground sample. The environmental operating envelope is adapted from MIL-STD-810H, with a temperate lower bound in place of the basic cold condition because the checkpoint and route-clearance scenarios considered here do not include arctic deployment [25].
3. Comparative Baseline: The Active Optical Spectroscopies
Four active optical spectroscopies dominate the post-2020 standoff explosive detection literature: Raman scattering, terahertz sensing, laser-induced breakdown spectroscopy and laser-induced fluorescence. This section presents them as a comparative baseline for the imaging architecture of Section 4, without attempting a comprehensive survey of each field. Each subsection states the physical principle in brief, the best demonstrated performance, and the limitation that constrains deployment. Section 3.5 then compares the four techniques with one another and draws the four conclusions that motivate the pivot to hyperspectral imaging.
3.1. Raman Spectroscopy
Raman spectroscopy identifies chemical compounds by illuminating a sample with a monochromatic laser and measuring the frequency shifts of the inelastically scattered light. Because these shifts arise from molecular vibrational modes, and a vibrational mode is Raman-active when it produces a change in molecular polarizability, the resulting spectrum provides a highly specific chemical fingerprint, albeit with an inherently weak signal [28,29].
Among the reviewed Raman literature, Abdallah et al. [28] provided the sole evaluation using benign confusants, successfully identifying six energetic materials (TNT, PETN, HMX, ammonium nitrate, ANFO and RDX) at 1 m with spectral matching scores of 95.6–99.9% against a signature library that also held sugar, salt and flour. Explosives mixed with benign material were tested in only two samples, HMX with flour and sugar, and TNT with sugar. However, reproducibility over time was limited, since additional samples measured several days later returned matching scores of only 79.8% for PETN and 67.5% for HMX.
Moving the source into the ultraviolet raises the cross-section and suppresses substrate fluorescence, and Cantu and Gallo [29] recover 0.76 g of RDX and 0.67 g of TNT at 50 cm across eighteen realistic war-zone substrates, with comparable microgram-scale results on dyed cotton under 264 nm excitation [30]. The best reported areal sensitivity in the reviewed Raman studies is approximately 0.5 g cm−2 for ammonium nitrate, achieved at a standoff distance of 3 m by Bykov and Asher [31]. TNT and PETN were measured only at approximately 50 g cm−2. This sensitivity requires continuous exposure of fresh residue to the laser beam, because deep-ultraviolet illumination photolyzes approximately 90% of an ammonium nitrate residue within 40 s. If the beam remains fixed on a single spot, the detection limit for ammonium nitrate degrades roughly ten-fold. At longer range, Hao et al. [32] detect bulk PYX, 2,4-DNT and TNT at 50 m on aluminum foil with a focusing lens alone and nothing applied to the target, the longest Raman standoff in Table 2. The same study’s 1 g cm−2 result at 30 m is not counted, because it required a silver plasmonic colloid sprayed onto the residue, a contact preparation step excluded under criterion (i) of Section 2.1.
Coherent Raman techniques replace the weak spontaneous signal with nonlinear optical gain, but only over limited propagation distances. Gatti et al. [33] demonstrate coherent anti-Stokes Raman scattering (CARS) imaging at 1 m using proxy analytes rather than energetic materials. Pfeuffer et al. [34] achieve a seventy-fold signal enhancement for potassium nitrate over working distances of only 5–15 cm, placing the experiment closer to laboratory microscopy than to practical standoff detection. Majumder et al. [35] reconstruct Raman images using a single-pixel compressive spectrometer, but require a scene acquisition time exceeding 615 s, and their 4 m demonstration employs a nitroaromatic surrogate rather than an explosive. Continuous-wave illumination is unsuitable for sensitive primary explosives: Wild et al. [36] show that, at a working distance of 1–2 cm, a pulse train above 95 W cm−2 leaves TATP intact, whereas a continuous-wave beam at one-third of that irradiance initiates ignition.
3.2. Terahertz Sensing
Terahertz spectroscopy probes the collective intermolecular vibrations, hydrogen bond deformations and lattice phonons of molecular crystals over the 30 m–3 mm spectral region. Because these modes depend on crystal packing as well as molecular composition, terahertz spectroscopy can distinguish polymorphs that are often indistinguishable by conventional vibrational techniques. In addition, terahertz radiation penetrates many non-polar dielectric materials, including paper, plastics and fabrics [37,38].
Jiang et al. [37] report the strongest performance among the reviewed terahertz studies, achieving 99.42% pixel-level accuracy for eight unconcealed chemicals and 88.83% for samples concealed beneath 0.18 mm of opaque paper, using a transformer-based edge detector followed by a 1D CNN classifier. Periketi and Chaudhary [38] confirm the maturity of terahertz chemometrics, reporting average accuracies of 95.6–98.9% across a five-explosive panel. Plekhanov et al. [39] show that scattering from particles comparable in size to the terahertz wavelength distorts the measured reflection spectra of RDX more strongly than substrate reflectance does, across surface loadings of 0.75–50 mg cm−2. Additional studies extend the terahertz spectral library to nitrocellulose, FOX-7 polymorphs, trinitropyrazole and packaged IED precursors, all measured either under dry-air purge or through thin containers [40,41,42,43].
The fundamental limitation is propagation range. No reviewed terahertz study reports a free-space standoff measurement because rotational absorption by atmospheric water vapour strongly attenuates terahertz radiation over meter-scale paths. This attenuation is comparatively weak within the atmospheric transmission windows near 353 and 200 m, but severe at the intervening absorption lines, such as 213 m, and exhibits an overall increase with frequency. Consequently, every terahertz measurement is performed either within centimetres of the focusing optics or under dry-air purge.
3.3. Laser-Induced Breakdown Spectroscopy
Laser-induced breakdown spectroscopy (LIBS) determines elemental composition from the emission spectrum of a microplasma generated on the target by a tightly focused laser pulse. Organic explosives are identified from the cyanogen (CN) and diatomic carbon (C2) emission bands that form as the plasma cools. However, both bands are also produced by benign organic materials, and CN forms additionally via the recombination of ablated carbon with atmospheric nitrogen; thus, discrimination relies on emission-band and atomic-line intensity ratios rather than the mere presence of CN or C2. Carbon-free inorganic explosives are identified from the intensity ratios of the atomic emission lines of nitrogen, oxygen, hydrogen, sodium, potassium, and chlorine, although the nitrogen and oxygen signals carry a common atmospheric contribution [44,45].
Shaik and Soma [44] generate a femtosecond filament at a standoff distance of 6.5 m and qualitatively discriminate RDX, HMX and TNT in the principal-component space of the CN emission band, with the first three principal components explaining 88% of the variance. They detect a 1 mg cm−2 CL-20 residue only after drop-casting silver nanoparticles onto the sample. Junjuri et al. [45] combine a compact non-gated spectrometer with single-shot nanosecond excitation at 6.5 m, achieving an average classification accuracy of 99.24% across five explosives, while maintaining false alarm rates below 6% per single-shot spectrum. Zhao et al. [46] achieve 100% accuracy on a six-class benchtop classification task using a ReliefF-SVM model based on six emission-line regions.
Water vapour absorption does not affect the ultraviolet–visible emission of the LIBS plasma. However, this does not eliminate atmospheric propagation losses: the excitation pulse must still traverse the atmosphere to reach the target, and the plasma emission propagates back through the same path while suffering the usual geometric collection loss. The fundamental limitations are twofold. Each laser pulse ablates and irreversibly consumes part of the residue it measures. Moreover, the irradiances required for optical breakdown place practical LIBS systems orders of magnitude above the Class 1 accessible-emission limits of the laser-safety standards ANSI Z136.1 and IEC 60825-1 [47,48], so the ocular hazard extends far beyond the focal volume.
3.4. Laser-Induced Fluorescence
Laser-induced fluorescence (LIF) detects chemical species by exciting them with laser radiation and measuring the longer-wavelength emission generated during relaxation. Because most field-deployed explosives exhibit weak native fluorescence, practical explosive detection relies on photofragmentation LIF: a deep-ultraviolet pulse dissociates the parent molecule into a strongly fluorescing fragment, nitric oxide for nitro-aromatics and nitramines, which is subsequently detected using a second probe pulse [49,50].
Bobrovnikov et al. [49] establish the two-pulse architecture at 5 m on TNT, achieving approximately twelve-fold fluorescence enhancement over simultaneous two-pulse exposure by synchronizing the probe pulse with the maximum fragment population. Companion studies from the same laboratory provide the only quantitative surface sensitivity among the LIF studies reviewed here, approximately 1 g cm−2 across five explosives deposited on aluminum foil [50], show that fingerprint residue signals fall steeply over the first forty transfers before levelling off [27], and extend the technique to vapours [51] and to an aerosol at 8.5 m using a chemical-warfare simulant rather than an explosive [52].
Puchikin et al. [53] merge fragmentation and probing into a single krypton–chloride pulse but observe fluorescence quenching as nitrogen pressure increases. An antibody-based immunoassay achieves a detection limit of 20 parts per trillion for TNT without cross-reactivity at fifty times that concentration [54]; as a zero-standoff contact assay, it serves only as the sensitivity benchmark for fluorescence transduction.
The fundamental limitations are provenance and atmospheric propagation. All standoff demonstrations reviewed here originate from a single laboratory, preventing assessment of independent reproducibility. The diagnostic nitric oxide emission lies in a deep-ultraviolet spectral region bounded by strong atmospheric absorption by oxygen and ozone. In addition, collisions with nitrogen and oxygen quench the excited nitric oxide fragments before they radiate, a loss mechanism that will also operate under ambient atmospheric conditions [53]. Finally, background tropospheric nitrogen dioxide undergoes photofragmentation through the same pathway as the analyte, contributing an irreducible fluorescence baseline.
3.5. Comparative Synthesis Across Techniques
Section 3.1, Section 3.2, Section 3.3 and Section 3.4 evaluate each technique individually. Table 2 sets the four side by side, and the comparison reveals four patterns, taken in turn below, that none of the individual accounts surfaces on its own.
Table 2.
Comparison of the four active spectroscopies of Section 3.1, Section 3.2, Section 3.3 and Section 3.4. All four are actively illuminated, and no reviewed study reports an environmental operating envelope or a moving target demonstration. Each cell gives the best value reported for that axis; cells within a row generally come from different experiments and must not be read as a single operating point.
The active spectroscopy literature lacks experimental replication. Although twenty-six papers were reviewed in Section 3.1, Section 3.2, Section 3.3 and Section 3.4 key publications from just five laboratories carry almost the entire table: Junjuri et al. [45] for LIBS, the Bobrovnikov group [27,49,50,51,52] for LIF, Abdallah et al. [28] for Raman, and Jiang et al. [37] and Plekhanov et al. [39] for terahertz. Outside these few core studies, individual papers have only contributed isolated data points. Furthermore, engineering continuity is absent: rather than building upon prior experimental setups, each laboratory restarts with a unique laser source, optical geometry, sample preparation and decision criteria. The apparent breadth of the table is therefore a parallel arrangement of independent demonstrations, not the additive output of a consolidating program. Consequently, no headline performance metric in the reviewed literature has been independently reproduced, making it impossible to verify whether these results would hold up on a different experimental bench.
Standoff and selectivity rarely coexist, and the mechanism is common to all four techniques. Long standoff and selectivity testing against a broad panel of benign confusants almost never appear in the same experiment. The exception is Junjuri et al. [45], who tested five explosives against nineteen benign confusants at 6.5 m with false alarm rates below 6% per single-shot spectrum, showing that the trade-off is not a law. Elsewhere, a common mechanism enforces it. Achieving metre-scale standoff requires high pulse energy, which introduces three constraints that limit confusant testing. The first is safety: focal irradiances of GW cm−2 sit far above the Class 1 limits of the laser-safety standards ANSI Z136.1 and IEC 60825-1 [47,48], and prolonged dwell is itself hazardous. Wild [36] reports that TATP survives a 95 W cm−2 pulse train yet ignites under a continuous beam at one-third of that irradiance, because the heated spot cools between pulses but not under continuous load. The second is sample destruction: stationary deep-ultraviolet illumination photolyzes 90% of an ammonium nitrate residue within 40 s [31], which restricts measurement to a few seconds per spot, whereas distinguishing an analyte from a nineteen-substance panel requires minutes of signal collection. The third is the data budget: long-range acquisition yields a single spectrum per location, which is insufficient to train a classifier without repeatedly exposing fresh sample material. The studies that train large panels [37,38,46] rely on controlled benchtop setups in which sample translation readily provides the datasets required, so these constraints do not apply to them. The trace column shows the same split. Loadings below the 10 g cm−2 scoring floor are reported only by Raman, as an estimated detection limit at 3 m on one inorganic analyte [31], and by LIF, as a lowest tested loading against no benign confusant [50]. Terahertz [39] and LIBS [44] sit two orders of magnitude above it. The evidence therefore points to a common constraint: comprehensive selectivity requires repeatable measurements, and repeatability remains easiest to achieve under laboratory conditions.
The obstacle is the same in every case. No technique in Table 2 achieves a complete imaging architecture, and in every case the limitation is structural. LIBS is intrinsically destructive because each laser pulse consumes part of the focal spot, so an image can be assembled only by translating a surface that progressively degrades during measurement. Raman is non-destructive but requires acquisition of a complete vibrational spectrum at every pixel, restricting imaging to serial raster scanning, whether by galvo mirrors [33], a translation stage [34] or 615 coded compressive masks for a single 64 × 64 frame [35]. Terahertz spectroscopy approaches true snapshot imaging only in Plekhanov’s microbolometer system [39], but each image is monochromatic, acquired one band-pass filter at a time, with spatial resolution fundamentally limited by diffraction at wavelengths of approximately 300 m. LIF achieves the highest areal acquisition rate through a 32-anode photomultiplier array [50], yet its parallelism is only one-dimensional: the illumination forms a line, while the second spatial dimension still requires mechanical scanning. Consequently, none of the four techniques acquires complete spatial and spectral information in a single integration.
Shifting from point detection to area detection is a structural change rather than an incremental extension of current systems. The four techniques (Raman, terahertz, LIBS, LIF) are fundamentally point- or line-interrogation architectures that image only by scanning. Because Raman, LIBS and LIF buy chemical specificity by pumping the analyte with high-fluence laser excitation, scaling them to wide-area spatial screening is bounded by photolytic sample damage, laser safety envelopes, and dwell-time limitations. Hyperspectral imaging offers what they lack: wide-field spatial mapping. The four active techniques cannot converge on hyperspectral imaging from within themselves, since the transition from point-probe characterisation to wide-area spatial identification requires an entirely different architecture. Fusing the four does not escape the constraint, because a fused platform inherits the joint safety envelope, the summed size, weight, power and cost (SWaP-C) budget, and the slowest channel. The slowest channel sets the pace of the whole platform: a shot-limited LIBS channel would restrict a higher-throughput LIF channel [50] to its own acquisition rate. Hyperspectral imaging is a different architecture, not an enlargement of theirs, trading narrow laser-pumped signatures for broader reflectance and emissivity features spanning the visible to the long-wave infrared. In exchange, it operates under broadband or solar illumination, delivers the full spatial-plus-spectral cube that none of the four reaches, and converts the moving target problem from a beam-pointing problem into one of dwell and coverage (Section 5). The shift is not free, since per-pixel signal-to-noise is lower, spectral resolution is coarser, and the chemistry is encoded in broad band shapes rather than sharp peaks.
4. Hyperspectral Imaging
Section 3.5 established the trade-off between hyperspectral imaging and the four active techniques: HSI offers a passive route, wide-area mapping and, in principle, access to a moving target, at the expense of lower per-pixel signal-to-noise ratio (SNR) and coarser spectral resolution. This section evaluates whether HSI recovers sufficient chemical specificity to serve as a deployable field detector. Addressing this question is particularly timely given the 2020–2026 progression of explosive-specific HSI from initial proofs of concept to its first ground-based, airborne and active-infrared demonstrations. This momentum builds on a mature analytical foundation, including spatial–spectral preprocessing, dimensionality reduction, spectral unmixing, chemometrics and deep learning, adapted from remote sensing and analytical chemistry. The target is demanding: trace-level explosives occupying a fraction of a pixel against cluttered backgrounds, and often in motion.
4.1. Physical Principles
A hyperspectral image is a three-dimensional data cube indexed by two spatial coordinates and one spectral coordinate (Figure 3), in which each pixel carries a contiguously sampled spectrum of tens to hundreds of narrow bands. That contiguity is what separates hyperspectral from multispectral imaging, although the boundary between the two is drawn differently across the literature, and it permits a material to be identified rather than merely detected. Given that the information a spectrum carries, and the illumination required to excite it, vary systematically across the optical spectrum, selecting the spectral region is the first design decision any optical detection system makes.
Figure 3.
Conceptual passive VIS–LWIR hyperspectral imaging chain for standoff explosive trace detection. An imaging spectrometer records a contiguous reflectance/emissivity spectrum for each pixel in the target scene, generating a three-dimensional data cube with two spatial dimensions (x, y) and one spectral dimension (). Spectral unmixing then decomposes mixed pixels into their constituent endmember signatures, shown here as schematic spectra.
The visible spectral range is governed by electronic transitions, and most fielded explosives are colourless, so spectral structure appears only when an active source drives photoluminescence, which reports electronic states [55]. The SWIR carries overtones and combination bands of the C–H, N–H and O–H fundamentals; these are diagnostic of chemical class but low in intensity, broad, and overlapping with one another [11]. The strongest and most chemically distinct signatures of energetic materials, the NO2 and O–NO2 stretching fundamentals (Section 4.3), lie within roughly 6–8 m, an interval that atmospheric water vapour strongly attenuates over standoff paths [56,57]. The weaker skeletal and deformation modes lie in the 8–14 m region. A design must therefore choose between the 6–8 m region, where the chemical signatures are strong but atmospheric propagation is strongly attenuated, and the 8–14 m region, where the bands are weaker but atmospheric attenuation is minimal.
The choice of region settles what can be seen; the choice of illumination settles whether it can be seen without a laser. In the reflective VNIR and SWIR, the signal is ambient light, usually solar, diffusely reflected from residue and substrate, so passive measurement requires daylight or another ambient source. In the emissive LWIR, passive detection exploits differences in spectral emissivity, which Kirchhoff’s law relates to absorptivity, and for residue and substrate in thermal equilibrium the contrast is spectral, not thermal, and the total surface-leaving radiance is governed by
where is the surface-leaving radiance at wavelength , the spectral emissivity, the Planck radiance at surface temperature , and the downwelling sky radiance. Active LWIR reflectance instead bypasses the temperature dependence of Equation (1) by introducing its own illumination, typically a high-irradiance tunable quantum cascade laser (QCL) or a dual-comb source [58]. By dominating the Planck emission and the downwelling sky term , the illumination isolates the reflectance , so the measurement no longer depends on the thermal contrast between residue and background. The price of active LWIR is increased system complexity and cost. It requires highly sensitive and often cryogenically cooled mercury–cadmium–telluride focal-plane arrays [59,60] and introduces laser speckle, which must be mitigated through spatial, angular or spectral averaging at the expense of dwell time. Active illumination also compromises covertness, because the emitted beam makes the sensor itself detectable.
Even when the spectral region and illumination are fixed, the target signal remains mixed with background clutter and environmental distortions. Although the residue carries the diagnostic bands, the substrate can dominate the pixel radiance: soda-lime glass, for instance, exhibits a strong Reststrahlen reflection peak near 9.5 m that overlaps the RDX fingerprint [60], while low-reflectance substrates can invert absorption bands into apparent reflection maxima. Particle size effects can distort LWIR spectral bands: Rayleigh scattering dominates for particles much smaller than the wavelength, whereas Mie scattering becomes important for particles comparable to the wavelength and can produce pronounced, size-dependent band-shape distortions [57,59]. Consequently, the target signature is a weak, sub-pixel and morphology-dependent signal.
Beyond surface clutter, atmospheric propagation alters the signal further before it reaches the sensor. In the reflective VNIR and SWIR, and equally in active LWIR, light travels two atmospheric paths, to the target and on to the sensor, and scattering adds path radiance that never touched the target, forcing the sensor to measure at-aperture radiance, from which the true surface reflectance must be retrieved. In the passive emissive LWIR the emitted signal travels a single path, but the atmosphere both absorbs and emits along it, yielding an at-sensor radiance equal to the surface-leaving radiance of Equation (1) attenuated by the atmospheric transmittance and increased by the atmospheric thermal emission along the path. Extracting intrinsic surface reflectance or emissivity therefore requires explicit atmospheric inversion (Section 4.4.1) or calibration against in-scene reference panels [56,61], and for emissivity a subsequent temperature–emissivity separation. Ultimately, passive sensing trades the power demand and safety hazards of active illumination for a dependence on illumination and weather conditions, making system performance as reliant on atmospheric correction as on optical design.
This gives rise to two key design implications. First, target detection and identification impose distinct constraints on spectral resolution and SNR. Consequently, a sensor capable of flagging a trace deposit at standoff distances may require closer proximity or expanded spectral coverage to achieve definitive chemical identification. Second, no spectral region or illumination scheme is universally optimal, as gains in specificity, standoff range or sensitivity are achieved only by conceding one of the others [56].
4.2. Sensor Configurations
A hyperspectral data cube has three dimensions, two spatial and one spectral, and a focal-plane array has two. Every hyperspectral imager must therefore trade off spatial or spectral dimensions by encoding the third dimension through temporal scanning or through multiplexing across the detector array. The four canonical acquisition architectures, whiskbroom, pushbroom, tunable filter and snapshot (Figure 4), represent different implementations of this trade-off [22]. The selected architecture determines the instrument’s spatial coverage, spectral fidelity, acquisition speed and per-pixel SNR, and thereby constrains the moving target and standoff performance of any hyperspectral explosive detection system.
Figure 4.
Hyperspectral acquisition architectures. Blue: captured in one exposure; arrows: scanned in time.
The whiskbroom, or point-scanning, imaging spectrometer disperses the light from a single ground point onto a linear detector and builds both spatial dimensions by mechanically scanning the field of view. It offers the highest spectral fidelity and the simplest optics but is the slowest architecture. In explosive sensing its scanning approach survives mainly in laser-raster form, in which a tunable QCL is swept in wavelength while its beam is rastered across the surface [58,59].
The pushbroom, or line-scanning, imaging spectrometer images an entire across-track line through a slit and disperses it onto a two-dimensional detector, capturing one spatial dimension and the full spectrum simultaneously while the relative motion between sensor and scene sweeps the second spatial dimension. It is the dominant architecture in the airborne and ground-based explosive HSI studies [62,63,64,65,66,67]. Its strength is high spectral resolution on a mature detector. Its weakness is that the second spatial axis is built from that motion. When that motion is uncontrolled, as on an airborne or vehicle platform, geometric fidelity depends on accurate georeferencing, and the achievable ground sampling is set by a coupled budget of altitude, speed and integration time in which radiometric quality is traded against spatial resolution [63,67].
The tunable filter imaging spectrometer inverts the pushbroom trade. It images the full two-dimensional scene at once through an electronically tunable bandpass and builds the spectrum by stepping the filter through successive wavelengths. It preserves spatial integrity without relative motion, which makes it natural for a static surveillance geometry. Its cost is temporal, since the scene must be spectrally scanned and motion of the target or of the sensor smears the scene across the wavelength sequence [56,61,68].
The snapshot imager removes even the temporal scanning constraint, capturing the entire cube in one integration by multiplexing spatial and spectral information across the detector [22,69]. Directly multiplexed devices cannot recover more voxels than the detector has pixels, so spatial sampling is traded against spectral sampling and band counts are of order tens rather than hundreds. No measurement with such a device appears in the explosive corpus, the single snapshot entry being a simulated scene [70]. This is important, because the moving target argument of Section 5 rests on an architecture that has not yet been exercised. Compressive designs circumvent this detector-pixel limitation by optically encoding the cube and computationally reconstructing a higher-dimensional estimate from fewer measurements. The reconstruction is therefore not unique, and the assumptions embedded in the algorithm influence the spectrum that is recovered [69].
Beyond those canonical four, the imaging Fourier-transform spectrometer (IFTS) recovers the spectrum from a per-pixel interferogram and so inherits the Fellgett (multiplex) and Jacquinot (throughput) advantages. The Fellgett advantage yields an SNR gain of across N spectral channels, but it holds only while the measurement is detector-noise-limited, as on an uncooled focal plane, and degrades under photon shot noise. This is what allows a Fourier-transform imager to reach fingerprint-scale resolution on an uncooled microbolometer [71,72]. Table 3 summarizes these architectures and their deployment implications.
Table 3.
Hyperspectral acquisition architectures relevant to standoff explosive detection, with the dimension each trades against time, the resulting deployment characteristics, and representative instruments in the corpus of Section 4.2, Section 4.3, Section 4.4 and Section 4.5. “Cube capture” denotes how the three data-cube dimensions (two spatial, x/y; one spectral, ) are acquired.
4.3. Spectral Fingerprinting of Explosives in HSI
An infrared spectrum reports molecular vibrations, and the vocabulary of those vibrations organizes Table 4. Fundamental vibrations are the lowest-energy transition of each normal mode of a molecule and comprise stretching and deformation (bending) motions. Stretching vibrations describe periodic changes in bond length and are classified as symmetric when equivalent bonds oscillate in phase and asymmetric when they oscillate out of phase. Deformation vibrations describe periodic changes in bond angle and include scissoring, rocking, wagging and twisting modes according to their geometry. For the explosives listed in Table 4, these fundamental vibrations produce absorption bands that are strong, sharp and spectrally distinct within the LWIR fingerprint region. At higher photon energies (shorter wavelengths), overtones occur near integer multiples of a fundamental frequency, while combination bands arise from the simultaneous excitation of two or more modes. Because these higher-order transitions are forbidden in the harmonic approximation and become allowed only through anharmonicity, their absorption intensities are much weaker than those of the fundamentals [11]. The overtones and combination bands of the C–H, N–H and O–H stretches of these compounds fall primarily in the SWIR. In the visible, vibrational structure gives way to electronic transitions, which for these compounds generally require active optical excitation, for example through absorption or photoluminescence [55].
The energetic materials considered here are characterised by a small number of diagnostic functional groups: the nitro group (NO2) in nitroaromatics (TNT, Tetryl) and nitramines (RDX, HMX); the nitrate-ester linkage (O–NO2) in PETN and nitroglycerin; the nitrate anion () in inorganic oxidizers; and the peroxide bond (O–O) in TATP and HMTD. Consequently, their hyperspectral signatures largely reflect the vibrational spectra of these functional groups, shifted and split by their molecular environment. These are the same vibrational modes that Raman interrogates under a complementary selection rule, since a mode is infrared-active when it changes the dipole moment and Raman-active when it changes the polarizability. The terahertz band of Section 3.2 does not reach these intramolecular fundamentals, probing instead the lattice and hydrogen bond modes of the same crystal.
Table 4 summarizes these signatures by compound. Read together with the studies reviewed in this section, it supports three general observations. First, chemical specificity increases from the visible to the LWIR, as the Region and Assignment columns show: the VNIR rows carry unassigned photoluminescence, the SWIR rows class-level overtones, and the LWIR rows assigned fundamentals. Passive accessibility follows the opposite trend, because the solar-rich VNIR and SWIR require no active illumination, while the most chemically specific fingerprint bands, in the LWIR, generally require either passive thermal contrast or an active infrared source. The reviewed literature exploits this entire continuum. Elbasuney et al. [55] identified TNT, RDX and PETN through electronically excited emission under 532 nm illumination. Van Damme et al. [11] discriminated explosive classes from weak overtone absorption in the SWIR, and separated potassium chlorate from perchlorate with an empirical discriminant, since no overtone band could be assigned. Sun et al. [75] employed a clock-synchronized QCL tuned to the symmetric NO2 stretching vibration of TNT near 7.4 m. Banas et al. [76] resolved the complete set of nitro and nitrate-ester fundamental vibrations in RDX, PETN and C-4 at the single-particle scale using optical photothermal infrared microscopy.
Table 4.
Spectral fingerprints of explosives accessible to hyperspectral imaging, grouped by compound. Each compound and its chemical class are listed once, and its diagnostic bands are followed by spectral region. Peak positions are wavelengths converted from the cited sources. Notes a and b follow the table.
Second, the positions and shapes of the fundamental bands are influenced by the molecular environment. The N–NO2 stretching vibration of RDX, for example, splits between the and polymorphs across 7.8–7.9 m [77], reflecting the same crystallographic sensitivity exploited by the terahertz lattice modes discussed in Section 3.2. In addition, Mie scattering by particles comparable in size to the wavelength alters band shapes as particle size changes [57], so a single reference spectrum cannot fully represent the spectral variability of a compound encountered under operational conditions.
Third, organic peroxides remain comparatively poorly represented within the hyperspectral literature. In the reviewed studies, TATP and HMTD are identified only at bulk level, through their class-specific short-wave infrared overtone spectra, and the additional bands of freshly prepared TATP arise from residual water and not from diagnostically useful O–O vibrational bands [11]. This persistent limitation reflects both the absence of strong class-specific fundamentals in the sampled bands and the scarcity of representative hyperspectral datasets, a challenge revisited in Section 5 as a broader data availability problem.
4.4. Data Processing
A hyperspectral data cube yields a detection only after a processing chain has calibrated the raw radiance, where needed reduced its dimensionality, separated the target contribution from the background, and rendered a decision. The explosive HSI studies rarely develop these methods themselves and draw them from the much larger literatures of remote sensing and analytical chemistry, which enter this review as supporting sources. The account below therefore describes the methods and, where they exist, the explosive-specific studies that apply them [80,81].
4.4.1. Preprocessing
The first preprocessing step is radiometric calibration, converting raw detector counts into physically meaningful reflectance or emissivity that can be compared across illumination conditions. Standard laboratory practice normalizes each pixel using a dark frame and a diffuse (Lambertian) reference panel of known reflectance. The reviewed explosive HSI literature follows this approach almost universally, whether by flat-field division against a white panel placed within the scene [65] or by the less expensive double-plate scheme with one dark and one bright panel, which can reduce the radiance-to-reflectance error below 10−4 [82]. Outdoors, this approach typically requires a white reference to be measured under the prevailing illumination conditions for each acquisition, and a substantial part of the ground-based explosive HSI literature is devoted to reducing this dependence. A static-background reflectance conversion method removes the need for a white reference after initialisation, preserving the spectral profile of the reference reflectance at a normalized cross-correlation of 0.999 across different acquisition days, although the absolute reflectance amplitude degrades [61].
For airborne campaigns, the inversion becomes fully atmospheric. The field has largely converged on several established atmospheric-correction tools, including the radiative-transfer model MODTRAN, the scene-statistics approximation QUAC [70], and the optimal estimation framework ISOFIT [9]. Recent accelerated optimal estimation algorithms perform the joint retrieval of surface reflectance, atmospheric water vapour and aerosol optical thickness sixty to ninety times faster than conventional solvers, requiring five to twenty milliseconds per spectrum and thereby bringing full atmospheric correction within reach of real-time onboard processing [9,70].
On the recovered reflectance, chemometric preprocessing suppresses the unwanted variability that obscures weak trace signatures. Common operations include scatter correction by standard normal variate (SNV) or multiplicative scatter correction (MSC), baseline correction using asymmetric or penalized least squares methods, and Savitzky–Golay smoothing and differentiation. Increasingly, these one-dimensional spectral operators are extended into joint spatial–spectral filters or two-dimensional convolution kernels that exploit spatial context unavailable to purely spectral preprocessing [82,83]. Because no single preprocessing method is universally optimal, the literature increasingly favours ensemble strategies that combine several complementary preprocessing pathways before classification. Such ensembles consistently outperform individual preprocessing methods and are particularly effective in the low-signal-to-noise regime characteristic of trace explosive residues [83]. For instance, the portable-SWIR and QCL-based soil-explosive studies reviewed here adopt this chemometric workflow directly, combining SNV with first-derivative Savitzky–Golay filtering [11] or vector normalisation against a KBr background [78] before classification.
4.4.2. Dimensionality Reduction
A data cube containing hundreds of contiguous spectral bands is often highly redundant, because most spectral features are broader than the band spacing and neighbouring bands are strongly correlated [84]. This redundancy does not weaken the case for hyperspectral acquisition, because the discriminating bands change with the analyte and the background. They cannot be fixed in advance, and the redundant bands acquired with them can degrade classification. With a fixed number of training samples, classification accuracy may initially improve and then deteriorate as additional bands are introduced, a behaviour known as the Hughes phenomenon and widely regarded as a hyperspectral manifestation of the broader curse of dimensionality [85]. Reduction is not always applied, since modern hardware processes the full spectrum. However, when labelled samples are scarce relative to the dimensionality of the feature space, as they are for trace explosive residues, reducing the spectral dimension is not simply an economy of representation but often beneficial for robust learning.
Two broad families address this problem. (1) Feature extraction projects the spectrum onto a lower-dimensional basis. Principal component analysis (PCA) selects that basis by variance, the minimum-noise-fraction (MNF) transform by signal-to-noise ratio, linear discriminant analysis by class separability and independent component analysis by statistical independence, while an autoencoder learns it by minimizing reconstruction error. These methods improve compactness at the cost of physical interpretability [4,85]. (2) Band selection retains a subset of the original bands ranked by information content, so every retained dimension remains a physical wavelength [67,68]. For instance, on biological tissue a standard-deviation-based selection scheme reduced data volume by up to 97.3% while maintaining 97.2% classification accuracy, and outperformed mutual information and entropy-based approaches [84]. Band selection thus preserves the spectral interpretability on which explosive identification ultimately depends.
When the bottleneck is the data link rather than the classifier, the same spectral redundancy is addressed through onboard compression. A recent review of hardware-accelerated hyperspectral compression catalogues predictive, transform, unmixing, and learning-based codecs implemented on FPGA, GPU, and system-on-chip platforms, and shows how such architectures make real-time downlink feasible [86].
4.4.3. Spectral Unmixing
Because a trace explosive residue typically fills only a fraction of a ground pixel, the measured spectrum is a mixture of the residue and its substrate, and recovering the residue is a spectral unmixing problem, the estimation, from the mixed pixel, of the constituent pure spectra (endmembers) and their fractional abundances. The linear mixing model treats the pixel as an abundance-weighted sum of endmembers under non-negativity and sum-to-one constraints. It underlies the classical pipeline: endmember extraction by vertex component analysis or N-FINDR, then abundance estimation by fully constrained least squares or by sparse regression against a spectral library, as in sparse unmixing by variable splitting and augmented Lagrangian (SUnSAL). Yin et al. [4] review the translation of that pipeline from remote sensing to analytical chemistry, tracing its shift toward autoencoder, variational and physics-informed learning. Two complications make explosive unmixing harder than macroscopic remote sensing, for which these tools were built.
The first complication is spectral variability. The same explosive presents different endmember spectra as polymorph, particle size, illumination and substrate change, so a fixed library systematically misfits [87]. The extended linear mixing model, multiple-endmember spectral mixture analysis (MESMA) and Bayesian and parametric variability models were developed to absorb this drift, as Borsoi et al. [88] review. Yin et al. [4] put a figure on the penalty, reporting that endmember variability can reduce the classification accuracy of linear unmixing by 15% to 30%. The figure is illustrative of a single scenario and should not be read as a constant.
The second complication is nonlinearity. A trace residue intimately mixed with a porous substrate produces multiple scattering that the linear model cannot represent, and bilinear and kernel models, and more recently autoencoder-based unmixing, are required. The endmember-guided unmixing network of Hong et al. [89] exemplifies the data-driven turn. It learns endmembers and abundances from vertex-component pseudo-endmembers in a two-stream network whose non-negativity and sum-to-one constraints are embedded as ReLU and softmax activations. Chen et al. [90] survey the broader integration of physics-based and data-driven models, where embedding the mixing physics into the network architecture, the priors and the loss function recovers the interpretability that pure autoencoders sacrifice. For forensic chemical mapping specifically, Kendler and Fishbain [91] identified nonlinear unmixing as the central unresolved obstacle, because it is the multiplicative mixing of a thin organic film with its background, not the additive sub-pixel case, which governs the trace regime. Explosive-specific evidence of the transferability of these methods to residues remains scarce, because they have seldom been tested on measured explosive residues. The reviewed studies demonstrate applicability only on a small number of substrates, at limited standoff distances, and under controlled laboratory or favourable daylight illumination. For instance, Breshike et al. [59] relied on synthetic spectra from a Mie scattering model for training and testing, with a qualitative result on RDX particles on glass. Kütük et al. [68] detected sprayed, fingerprint and car trunk ammonium nitrate residues, including mixed pixels containing both the plate and the residue, with an unmixing-based detector. That detector assumed a linear mixing model, and nonlinear models were left for future work. On solid ammonium nitrate, the same detector outperformed learning-based approaches when training data were limited. Consequently, current evidence supports the use of these methods under restricted conditions, but their robustness to operational variability remains unestablished.
4.4.4. Classical Chemometrics
Classical chemometric methods ask whether a known target is present and, in some cases, in what quantity, and they fall into two groups. The first, data-driven chemometric models, learn their decision rules from a training set of measured spectra. The second, spectral matching methods, need no training set and compare each measured spectrum with a reference spectrum of the target. Most quantitative explosive HSI results are reported with one or the other [11,58,60,68,78].
Among data-driven chemometric models, principal component and partial least squares models, linear discriminant analysis, support vector machines and random forests carry the identification and quantification load. A study with a portable SWIR spectrometer identifies intact explosives from four organic explosive classes using a multi-stage chemometric method that combines linear discriminant analysis (LDA) with a net analyte signal (NAS) stage. The method also achieves 100% discrimination between the inorganic oxidizers potassium chlorate and potassium perchlorate and reports no false positives on the evaluated curated negative set, which includes household and food substances, hoax materials, drugs of abuse and explosive precursors [11]. A QCL-soil study quantifies 2,4-DNT with detection limits between 0.8% and 1.4% by mass depending on the soil matrix, using partial least squares regression, and distinguishes DNT-, TNT- and RDX-contaminated from clean soil at 99.6% accuracy with a random forest [78].
Among spectral matching methods, the matched filter (MF), adaptive cosine/coherence estimator (ACE), constrained energy minimisation (CEM), and orthogonal subspace projection (OSP) compute a per-pixel detection statistic using an estimated background model, whereas the spectral angle mapper (SAM) and spectral correlation compare the measured spectrum with the library spectrum directly, without an explicit covariance estimate [58,60]. A ground-based ammonium nitrate study benchmarks this detector family directly and identifies a hybrid structured-detector (HSD) approach as the best performer, with ACE second and SAM worst [68].
Two refinements are particularly important in the trace regime. First, standard detectors assume that the background statistics remain unchanged when the target is present. A robust adaptive matched filter that tolerates background mismatch improved detection in simulations on real airborne data when the target signature was imperfectly known [92]. Second, many classical detectors rely on a single background covariance, which a non-stationary scene violates. Image segmentation prior to detection can therefore either sharpen or degrade subpixel-target performance. Its effect depends on target power and background covariance structure, and this dependence is now sufficiently well characterised to predict when segmentation is beneficial [93].
The methods above all operate on data from a single sensor. When several spectroscopic sensors are combined, multi-block chemometric methods such as sequential orthogonalized partial least squares (SO-PLS), common dimensions analysis (ComDim), and joint and individual variances explained (JIVE) extend the data-driven group. They provide a principled framework for fusing heterogeneous spectral data while accounting for the different information that each block contributes to the joint model [94].
4.4.5. Machine Learning and Deep Learning Approaches
Deep learning has displaced hand-engineered features as the default for hyperspectral classification. The trajectory runs from spectral-only multilayer perceptrons, through spectral-spatial convolutional networks, to attention and state-space models, and is well documented in the surveys of Ahmad et al. [85] and Song et al. [95]. The canonical convolutional architecture stacks a three-dimensional convolution that learns joint spectral-spatial features over a two-dimensional convolution that abstracts spatial structure, as in the HybridSN model of Roy et al. [96] that remains a standard baseline.
Transformers reframed the spectrum as a sequence. Hong et al. [97] learn group-wise spectral embeddings from neighbouring bands with cross-layer adaptive fusion in their transformer network, SpectralFormer. Roy et al. [98] inject a complementary-modality token into the patch-token stream to fuse hyperspectral data with light detection and ranging (LiDAR) or synthetic-aperture radar (SAR) data. The quadratic cost of self-attention has in turn motivated state-space (Mamba) models, and He et al. [99] claim global dependency modelling at linear complexity, a property directly relevant to the size, weight and power budget of a deployable detector [100].
Three mitigations recur in response to the chronic scarcity of labelled hyperspectral data. First, Hong et al. [101] address the problem through large-scale pretraining without labels, training a generative pretrained transformer (SpectralGPT) on more than one million spectral satellite images. Second, Ran et al. [102] and Y. Zhao et al. [103] adapt to new classes from only a handful of labelled pixels using few-shot and meta-learning under spectral shift. Third, complementary modalities such as LiDAR elevation and SAR backscatter supplement the spectral channel through multimodal fusion [104,105,106,107].
The explosive and hazardous material-specific deep learning literature is, by comparison, recent and fast-moving. C. Chen et al. [79] identify six hazardous chemicals, among them TNT, RDX, PETN and ammonium nitrate, at 91.1% accuracy with a one-dimensional convolutional network on pushbroom data. Sun et al. [108] classify nine solid hazardous materials from VNIR reflectance at 93.9% classification accuracy with an improved ResNet. D. Zhao et al. [109] fuse a spectral convolutional and bidirectional long short-term memory network (CNN–BiLSTM) with a U-shaped segmentation network (U-Net) to classify explosive fragments at 96.4% overall accuracy, though at a distance of 30 cm on a laboratory bench rather than at standoff. The synthetic route is also represented. Breshike et al. [59] train their classifier entirely on Mie scattering-simulated spectra and recover an estimated nanogram-per-pixel RDX loading, and Bajić Jr. and Bajić [70] model a UAV survey by implanting measured UXO endmembers into real hyperspectral terrain.
These early results are encouraging. They do not yet match the maturity of land cover classification, which benefits from widely used public benchmark data sets of airborne hyperspectral imagery, such as Indian Pines, Pavia University, and Houston [85,96]. This contrast highlights the substantial scope for further development in explosive HSI [110,111,112].
4.5. Field Suitability Under Operational Constraints
Measured against the operational thresholds for field deployment, the explosive HSI corpus splits cleanly into a passive branch and an active branch, and the two occupy almost complementary regions of the deployment space. The passive branch interrogates the VNIR and SWIR under solar or ambient illumination and reaches genuine standoff, but at a sensitivity far above the trace regime. Meanwhile, the passive thermal-LWIR route remains empirically vacant for radiometric reasons detailed in Section 5. The active branch trades standoff for sensitivity. By illuminating the molecular fingerprint region with a laser source and measuring the diffuse backscatter, it reaches a trace regime that passive LWIR imaging has not yet demonstrated.
In the passive branch, C. Chen et al. [79] deposit six hazardous chemicals (potassium chlorate, ammonium nitrate, TNT, RDX, PETN and PYX) on aluminum plates at 100 mg cm−2. A SWIR (900–1700 nm) pushbroom imager reads them at 2–10 m, and a one-dimensional CNN classifies them at 91.1% in a three-second scan against sugar and flour confusants. The same system records the absorption bands of ammonium nitrate at 50 m, without a classification result at that range, so 10 m is the standoff entered in Table 5. Reflectance spectra recorded at lower surface densities remain distinguishable down to 10 mg cm−2 for ammonium nitrate and TNT. This value rests on spectra alone, not on a detection test, so Table 5 and Table 6 enter 100 mg cm−2 as the lowest tested loading. Even the lower value sits three orders of magnitude above the 10 g cm−2 scoring floor of Table 1. Kütük et al. [68], extending the ground-based SWIR line established by Koz [61], detect granular ammonium nitrate at about 8 m, sprayed (250 g/L) and fingerprint ammonium nitrate residues on painted metal plates, and they confirm AN and RDX on a stationary car trunk at 7 m and ammonium nitrate hand residues at 7 m and 15 m. Their hybrid structured detector couples spectral matching to unmixing and reports a false positive rate of 0.005% at 100% recall on a fifty-fingerprint grid. That figure is not a per-pixel rate, nor a per-inspection rate; it is a sliding-window rate. The method slides an 8×8-pixel window across the scene and declares that window positive whenever more than 20% of its pixels are positive, and the reported rate is then computed over the full data cube. So it counts window-level false positives, not pixel- or object-level ones. With that qualification stated, it is the strongest selectivity result in the passive corpus, but it comes with no accompanying trace areal concentration. The airborne and ground-vehicle studies reach standoff distances up to tens of meters. Manley et al. [65] detected RDX indirectly through the physiological stress induced in maize grown over soil dosed at 250–500 mg kg−1, using a VNIR pushbroom imager at 30 m altitude and separating exposed plants from drought-stressed and control plants with an SVM at 73–78% accuracy. Sun et al. [108] classified solid hazardous materials, among them a potassium nitrate, sulphur and carbon mixture (black powder), placed on the ground from a building-mounted VNIR imager at approximately 30 m, achieving 93.9% accuracy with an improved ResNet. Tuohy et al. [66] resolved the PFM-1 antipersonnel mine and other surficial ordnance on bare soil and grass using a VNIR pushbroom imager at 10 m, identifying the targets by inspection of spectral profiles, three-band colour composites and a principal-component band image, without an automated decision rule. Chaudhary et al. [67] mounted a VNIR pushbroom imager on a moving all-terrain vehicle to map ammonium nitrate, TNT, and C-4 on soil, establishing an operating point of 90 cm sensor height, 0.5 cm minimum mapping size, and 10.5 cm s−1 vehicle speed that yielded more than 70% accuracy with a 22-band SVM. All those studies relied on solar or ambient illumination, and none demonstrated operational trace sensitivity.
Table 5.
The explosive-material hyperspectral-imaging corpus (2020–2026) against the deployment requirements. “P” = passive (solar/thermal); “A” = active (laser/lamp). Figures of merit are transcribed from the source papers and, where the source permits, restated as an areal concentration or as a time per ground sample. The note follows the table.
Table 6.
Operational thresholds for hyperspectral imaging, contrasting the best value reported by the passive (solar/thermal, VNIR and SWIR) and the active (laser, MWIR/LWIR) branch of the hyperspectral corpus on each of the seven axes. “Not reported” marks an axis on which no paper in that branch reports a measurement. The compliance columns apply the rule of Section 2.2: satisfied, indicative, non-comparable, not satisfied or not reported; “bulk” marks a result obtained on bulk deposits only.
In the active branch, Breshike et al. [59] detected RDX on glass at approximately 1 m using active LWIR (6–11 m) backscatter, reaching an estimated per-pixel loading of about 21 ng and achieving 87.8% classification accuracy on held-out synthetic spectra with a CNN trained entirely on Mie scattering-simulated spectra covering 44 analytes on nine substrates. Goyal et al. [60] imaged RDX and PETN on eleven test-and-evaluation substrates at approximately 0.1 m with a tunable QCL, recording reflectance spectra for RDX on glass across 0.8–69 g cm−2 and discriminating the residue by pixel-wise spectral similarity to a reference spectrum. Macarthur et al. [58] detected RDX and PETN on ZnSe, aluminum, and PLA at 3 m using an approximately 8 m dual-comb spectrometer, reaching an estimated 2–8 g cm−2 by spectral (Pearson) correlation and mapping an 18 × 18 cm field in 2.5 s. Dreier et al. [77] used a 6–11 m QCL at a standoff distance of approximately 1 m to detect RDX, TNT, PETN, and ammonium nitrate deposited on six fabric substrates. Deposited masses ranged from 400 g to 10 mg on fabrics, while printed RDX loadings on quartz went down to 50 g cm−2. Identification relied on comparing diagnostic peak positions with FT-IR reference spectra. The study also included seven benign confusants, and unsupervised PCA was used as an exploratory tool. PCA separated TNT from paracetamol but not all measured substances.
Two additional studies complete the operational picture. Elbasuney et al. [55] detected TNT, RDX, and PETN traces on a fingernail at benchtop range through 532 nm-excited photoluminescence, segmenting the responses by unsupervised k-means clustering after KNN smoothing, although the deposited amounts were not reported. Zhao et al. [109] classified metallic explosive fragments on stone, soil, bark, and two additional backgrounds at 30 cm using a VNIR pushbroom imager under halogen illumination, achieving 93.8% classification accuracy with a CNN–BiLSTM, 93.5% segmentation accuracy with a U-Net and 96.4% overall accuracy when the two are combined. In summary, Table 5 arranges the reviewed corpus along the deployment axes, and Table 6 reduces it to the seven operational thresholds by contrasting, for each threshold, the best passive and best active result.
Synthesis. Across the experimental studies summarised in Table 5, the passive branch satisfies two thresholds, standoff and acquisition speed, on bulk deposits only, the active branch reaches the trace floor with indicative evidence only, and five thresholds are satisfied by neither (Table 6). Classification accuracies obtained using bulk deposits, ordnance or proxy materials (Table 5) are reported separately as evidence of material discrimination or identification but are not treated as evidence of detection sensitivity against any quantitative threshold. Standoff of 10 m or more is achieved only by the passive branch [65,66,68,79,108], and tested or estimated loadings below the 10 g cm−2 trace floor are reported only in the active branch [58,60], without a detection limit. This is the same standoff-versus-sensitivity trade-off identified in Section 3.5 from a physical perspective, here recast as a passive-versus-active design constraint.
Within the remaining requirements, the evidence narrows to a single study in each case. A false positive rate is reported only once, at 0.005% per 8 × 8 pixel window [68]. The largest reported selectivity panel identified in the explosive HSI literature comprises seven benign substances (listed in Table 5) [77]. Performance reported against such panels provides preliminary evidence of selectivity. These studies generally do not report detection probability at a predefined false alarm operating point, preventing direct assessment against the operational requirement. Where relative motion is evaluated, it is the sensor platform that moves rather than the target [67]. Acquisition speed against a moving target is met in the passive branch [79] and not in the active branch, where the point scanner is fast enough for a single spot but not for target coverage [58] and the QCL imager, which steps wavelength, is fast enough for neither [60]. Acquisition speed cannot be assessed directly from the different metrics the studies report, such as frame rates, integration times, scan durations and complete-cube acquisition times. The dwell condition is therefore assessed on the time per ground sample of Table 5 (Section 2.2), and the coverage condition in Section 5.
Environmental robustness and moving target capability remain the two clearest unresolved axes across both the active spectroscopies of Table 2 and the HSI branches of Table 6: none reports a measured atmospheric two-way transmittance, a formal environmental operating envelope, or a moving target detection-limit curve. The absence of these experimentally quantified benchmarks highlights an important gap in the current evidence base and defines a clear priority for future validation studies.
What hyperspectral imaging might contribute to the active optical spectroscopies of Section 3 is consequently distinctive. It provides the passive, full-cube, area-mapping architecture that none of them achieves, together with a moving platform survey geometry that none of them attempts, at multi-metre standoff. The research agenda that follows is equally clear: improve trace sensitivity, quantify the false positive rate, and establish the environmental-envelope and moving target evidence required for a deployable detector. The central design tension is that the passive branch that achieves standoff remains the branch furthest from the operational trace threshold. Section 5 addresses these unresolved challenges.
5. Challenges and Open Research Directions
Table 6 maps the current research gaps against the seven operational thresholds defined in Section 2.2. To address why these requirements remain unmet, this section synthesizes the reviewed literature into seven technical challenge groups. These challenge subsections are arranged in a logical progression, moving from the physics of optical measurement outward to the engineering architecture of field-deployed instruments. A central theme throughout these challenges is that the main advantages of hyperspectral imaging, passive illumination and wide-area spatial coverage, come at a cost: reduced signal-to-noise ratio, lower environmental robustness, and a need for broader experimental validation. Furthermore, none of these seven challenge areas can be resolved in isolation. Each links back to the core sensitivity–specificity–standoff trade-offs established in Section 4.1 (Physical Principles), where gaining performance along one operational axis typically degrades another. Consequently, the primary objective for future research is not to maximize any single threshold, but to identify an optimal operating point where all seven operational requirements are met simultaneously for a stated mission.
5.1. Physical and Spectral Constraints
The fundamental constraint is that the most accessible spectral region is not the most diagnostically informative one. The solar-rich VNIR and SWIR domains require no active illumination and can be measured with comparatively inexpensive detectors, but they contain mainly weak, broad overtone and combination bands of the C–H, N–H and O–H fundamentals, which are useful for broad chemical discrimination yet generally lack the sharp specificity of fundamental vibrational features. By contrast, the LWIR fingerprint region contains the strong and chemically specific nitro and nitrate stretching bands but accessing them requires either thermal emissivity contrast or active laser illumination [11,57].
This regional trade-off is compounded by the trace residue problem. An operational explosive residue is a discontinuous deposit of micrometer-scale particles occupying only a fraction of a pixel, so its weak spectral contribution is mixed, often nonlinearly, with the substrate spectrum. The substrate may dominate the pixel through its own reflectance or Reststrahlen structure and can even transform an apparent absorption feature into a reflection maximum [59,60].
Morphology introduces a further constraint. Because Mie scattering depends on particle size relative to wavelength, the observed band shape becomes particle size dependent, and a single library spectrum cannot reliably represent a compound across the full range of residue morphologies encountered in practice [57].
These constraints leave two structural gaps in the evidence. (1) Peroxide explosives such as TATP and HMTD carry no nitro chromophore, and no reviewed HSI study targets them. Their short-wave infrared spectra are distinctive enough for bulk identification [11], but trace detection of this class remains undemonstrated. (2) Passive LWIR detection can fail when the target surface and the downwelling sky radiance have similar brightness temperatures, as may occur under overcast, foggy, or high-humidity conditions. Although the emissivities remain different, the contrast between emitted and reflected radiance becomes very small, and the resulting spectral signature may fall below the sensor’s detection limit.
5.2. Environmental Variability
Passivity makes the measurement intrinsically dependent on illumination and atmospheric conditions. The at-aperture spectral radiance recorded by the sensor is
where the surface reflectance contains the target-specific spectral signature, whereas the solar irradiance , the solar-zenith term , the downwelling and upwelling atmospheric transmittances and , and the path radiance are governed primarily by the environment.
As Equation (2) shows, variations in solar geometry, cloud cover, humidity, and temperature reshape the measured spectrum, and the ground-based SWIR work of Koz [56,61] demonstrates the practical consequence: reflectance estimates derived from white-panel calibration remain reliable only under comparable illumination and atmospheric conditions, motivating extensive efforts toward orientation and day-to-day normalisation schemes. Atmospheric absorption further limits usable spectral regions, particularly through water-vapour bands in the SWIR and reduced-transmission intervals in the LWIR, making accurate atmospheric correction a critical component of quantitative retrieval. Recent advances in scene-specific compensation have improved its feasibility [9].
Surface bidirectional reflectance effects, shadowing, and heterogeneous backgrounds further increase false alarm susceptibility, while moving platform acquisition introduces additional variability through continuously changing observation geometry [67]. However, the reviewed literature contains no quantitatively defined environmental operating envelope spanning illumination and weather variability, leaving a major validation gap before operational deployment claims can be substantiated.
5.3. Data Scarcity and Domain Shift
Deep learning has substantially advanced land cover hyperspectral classification through standardized and repeatedly reused benchmarks such as Indian Pines, Pavia University and Houston [85,96], whereas explosive HSI lacks an equivalent foundation. labelled hyperspectral cubes of real explosive residues acquired on realistic substrates remain scarce, expensive and hazardous to generate, and no widely adopted public benchmark currently captures the operational variability of explosive scenes, including realistic substrates, acquisition conditions and target distributions.
Consequently, the field relies on surrogate strategies. Breshike et al. [59] used Mie scattering simulations to generate spectral variability for backscatter classification, whereas Bajić Jr. and Bajić [70] inserted measured ordnance endmembers into real terrain data to synthesize survey scenes. Models developed under one acquisition distribution can nevertheless degrade substantially when evaluated under another, as demonstrated by Vivoli et al. [113], whose landmine detector performed well on in-distribution measurements but lost accuracy on an out-of-distribution set collected over different terrain, where grass cover occluded the targets.
Mitigation strategies from the broader machine learning community are increasingly being explored for explosive sensing, although their operational validity remains insufficiently established. These include the few-shot and meta-learning approaches with explicit cross-domain alignment of Ran et al. [102] and Y. Zhao et al. [103], spectral foundation models such as the SpectralGPT of Hong et al. [101], pretrained on large-scale unlabelled spectral data, and the statistical models of spectral variability that Borsoi et al. [88] used to characterise domain shift. Until these approaches are systematically evaluated on explosive HSI under realistic domain shifts, reported accuracies should be interpreted primarily as measurements of in-distribution discrimination capability rather than as evidence of field-ready performance [95].
5.4. Algorithmic Robustness and Interpretability
A deployable detector must provide both reliable performance and decision transparency, yet current deep models do not provide these properties by default. They remain vulnerable to distribution shifts and adversarial perturbations. Tang et al. [111] demonstrated that small perturbations can reduce hyperspectral classification accuracy from 97.4% to 22.7%, while Chen et al. [112] quantified broader model fragility under data and network perturbations through mutation testing.
Their limited transparency is also a major constraint in security applications where a detection decision may trigger intervention. Recent responses have followed two complementary directions. Lee et al. [110] employed explainable-AI approaches, including attention visualisation, prototype analysis and LIME/SHAP attribution, to reveal spectral evidence supporting few-shot classification decisions, whereas Hong et al. [89] and Chen et al. [90] incorporated physical mixing models into network architectures so that estimated endmembers and abundances retain spectroscopic meaning rather than representing unconstrained latent variables. The robust adaptive matched filter of Vincent and Besson [92] provides a classical counterpart, an interpretable detector based on correlation with a known target spectrum that improves tolerance to background mismatch at a controlled cost in peak sensitivity.
Whichever direction is taken, a fundamental reporting gap remains. The reviewed studies rarely provide the ROC curves, calibrated false alarm rates, uncertainty estimates and independent-condition evaluations required to establish robustness for operational deployment.
5.5. Deployment Constraints (SWaP-C, Real-Time Processing)
A hyperspectral cube is a high-volume data product generated at acquisition speed, and a deployed instrument must process it within the size, weight, power and cost (SWaP-C) envelope compatible with vehicle or UAV operation while maintaining a frame rate consistent with platform motion [67]. Data throughput is the first constraint. Even a single SWIR cube can represent hundreds of megabytes, such that repeated acquisition rapidly challenges embedded buses and communication links. This limitation has motivated dedicated architectures such as the dual-processor FPGA–ARM design of Yang et al. [114], which sustains camera-limited acquisition rates on a flight-compatible platform. Hardware compression can reduce downlink requirements but does not remove the computational burden of onboard processing [86].
The inference model represents a second constraint. Transformer self-attention introduces unfavourable computational and memory scaling for embedded hyperspectral inference, motivating sparse and other efficient attention mechanisms [100], linear complexity state-space models [99] and lightweight convolutional architectures [96], although their application to explosive hyperspectral cubes remains largely unexplored.
The optical subsystem imposes a third constraint. Cryogenically cooled mercury–cadmium–telluride focal planes, often required when high LWIR sensitivity and spectral resolution are targeted, represent a major contributor to infrared system SWaP-C. However, the reviewed literature rarely reports complete mass, power, or cost breakdowns. The emergence of an uncooled thermal-infrared camera based on a birefringent interferometer is therefore significant because it provides useful spectral resolution without cryogenic cooling [72]. Active systems introduce additional constraints through QCL source integration and thermal management [60], whereas passive systems exchange source complexity for larger collecting apertures and atmospheric-correction requirements.
Finally, model optimisation and optical hardware converge at deployment. The relevant performance metric is not workstation accuracy, but the accuracy sustained after pruning, quantisation, and knowledge distillation under embedded resource constraints. These compression strategies introduce measurable trade-offs between parameter reduction, latency, energy consumption, and accuracy, yet such deployment degradation is rarely reported alongside benchmark performance. A deployable explosive detector should therefore be characterised by post-deployment performance under realistic SWaP-C constraints, including sensor mass, power consumption, and system cost.
5.6. Dynamic Scenarios (Static vs. Moving Target Trace Detection)
The operational capability that most clearly differentiates HSI from the Section 3 techniques is moving target sensing, where the acquisition architecture discussed in Section 4.2 becomes decisive. However, no reviewed study has yet demonstrated it (Table 6). Whiskbroom, pushbroom and tunable filter instruments construct hyperspectral cubes sequentially. Relative target motion during acquisition can therefore introduce spatial smearing, spectral misregistration, or incomplete sampling across the wavelength sequence. Snapshot instruments avoid this temporal scanning constraint, although this advantage is exchanged against spatial–spectral resolution and photon-efficiency trade-offs [22].
The limited literature addressing motion has examined only the platform side, characterizing the operating region in altitude and velocity and identifying the speed beyond which mapping resolution deteriorates [67]. Existing moving platform studies address bulk deposits [65,66,67], and trace-sensitive measurements remain restricted to static benchtop acquisitions [58,59,60].
A moving target imposes two conditions: each ground sample must be acquired within the dwell time specified in Table 1, and the entire target must be covered while it remains in view. The acquisition requirements depend on the imaging architecture (Section 4.2). Pushbroom imagers can satisfy both conditions: each frame captures a full target line across all wavelengths, and the fastest reviewed instrument acquires it within the required dwell [79], whereas the second fastest requires twice that time [108]. For a person-sized target, the complete set of lines can be acquired within a fraction of its viewing time, although geometric fidelity depends on target motion (Section 4.2). However, both instruments were tested on bulk deposits, and the moving-platform study reporting its platform speed operated at one-tenth of walking speed [67]. Active imagers demonstrate trace sensitivity but acquire wavelengths sequentially, so even a single sample requires two to ten times the allowed dwell [60] or tens of seconds [59]. Reducing the number of wavelengths shortens acquisition but sacrifices spectral information [60]. The point scanner meets the dwell requirement for a single spot [58], but covering a two-dimensional target requires scanning it spot by spot within its viewing time. The only snapshot entry in the corpus is a simulated scene [70]. Thus, acquisition speed has been demonstrated with passive pushbroom imaging on bulk deposits, and trace sensitivity with static active systems, but the two have yet to be shown together at the required dwell time.
As anticipated in Section 3.5, moving target trace detection is governed by the trade-off between frame rate and SNR: shorter integration times reduce motion blur but decrease photon collection, directly challenging the weak signals associated with trace residues [79]. Snapshot and computational-imaging architectures mitigate temporal scanning artefacts but do not eliminate this photon-limited constraint. Spatial–spectral resolution trade-offs and reconstruction uncertainty further influence detection performance [22,69]. Consequently, no reviewed study has yet quantified the detection-performance trade-off between target velocity, integration time, and trace residue sensitivity under controlled conditions.
5.7. Underexplored Dimensions: LWIR HSI and Polarisation
The most promising underexplored direction is long-wave infrared (LWIR) hyperspectral imaging, primarily because of its spectroscopic advantage. The infrared fundamental-vibration region provides some of the most chemically specific signatures available for energetic materials, where nitro-, nitrate-ester, and related functional-group vibrations generate distinctive absorption features (Table 4). Consequently, measurements approaching operational trace detection levels have predominantly relied on LWIR active illumination within short source–detector geometries [58,59,60,77]. Among these studies, only two report a directly comparable areal loading below the scoring floor, as a lowest tested loading [60] or an estimate [58], not as a detection limit. The remaining demonstrations either report quantities that cannot be converted to an areal concentration [59] or quantify mainly deposited mass instead of surface detectability [77].
The remaining challenge is therefore primarily one of deployment. LWIR offers a passive pathway through thermal emissivity contrast, potentially combining the molecular specificity of active spectroscopy with the operational advantages of passive sensing, including reduced illumination requirements and improved SWaP characteristics, although sensor cost remains the main obstacle for LWIR [57]. Practical implementation remains limited by several coupled factors: detector requirements, emissivity–temperature ambiguity, reduced contrast when the surface and sky brightness temperatures converge, atmospheric transmission losses over relevant spectral intervals, and scattering effects for particulate residues.
Active LWIR HSI remains dependent on laser illumination and shares the fundamental constraints of active point spectroscopy: under a fixed laser power budget, distributing the illumination over a larger area reduces the signal available per pixel, and the integration time available to compensate is bounded by the dwell-time requirement of Table 1. For a diffusely reflecting surface, the power received by one pixel increases with laser power, surface reflectance, pixel footprint and receiver aperture, and decreases with illuminated area and the square of the range, with two-way atmospheric transmission (Section 4.1) as an additional loss. The eye safety limit on target irradiance [47] caps the laser power available to compensate. The reviewed demonstrations operate under favourable conditions: centimetre-scale spots at metre-scale ranges, at a fraction of the eye-safe irradiance, with tens of seconds per cube or milliseconds per point [58,59]. Other reviewed studies acknowledge that greater range or coverage requires proportionally more laser power [60,77]. Extending these configurations to the square-metre area targeted by one of the reviewed programs [60], at the standoff floor of Table 1, therefore reduces the signal per pixel by the illuminated area ratio and the squared range ratio, beyond what the margin below the eye safety limit can recover. A complete photon budget would also require the detector noise-equivalent power, the integration time, the optical throughput and the bandwidth, which no reviewed imaging study reports together. On the present evidence, whether wide-area active LWIR imaging can maintain trace sensitivity at operational standoff under eye-safe illumination therefore remains an open question.
Two recent developments address individual components of this challenge. Corti et al. [72] demonstrated an uncooled thermal-infrared camera, based on a birefringent interferometer, which reduces reliance on cryogenic detectors. Wang et al. [69] recovered high spectral resolution from coarse uncooled snapshot measurements through computational reconstruction. Neither approach has yet demonstrated suitability for trace detection. The uncooled camera of [72] uses a microbolometer whose sensitivity is characterised thermally and not against a reflectance noise floor, whereas the reviewed trace-detection demonstrations relied on cooled detector arrays [59,60], one of which achieved a reflectance noise floor below [60]. Furthermore, the seventeen spectral channels of [69], separated by approximately 0.4 m, are too widely spaced to directly resolve the separations between neighbouring fundamental absorption features listed in Table 4, many of which are 0.2 m or less. Although spectral reconstruction was investigated, its validation was limited to library spectra and gas measurements, rather than explosive residues. These advances remain largely independent and have not yet been integrated or validated for explosive analyte detection.
The next step that follows from these developments is system integration. One possible direction is an LWIR hyperspectral architecture that combines active illumination in the fingerprint region with an uncooled detector front end and the computational spectral reconstruction reported in the recent literature [69,71,72]. In principle, such a system could operate passively when ambient thermal contrast is sufficient and invoke QCL-assisted illumination when passive contrast becomes inadequate. If these components can be integrated without unacceptable penalties to the photon budget and detector sensitivity discussed above, the spectral resolution recoverable through computational reconstruction [69], atmospheric transmission (Section 4.1), calibration stability, synchronisation, or power consumption, the resulting architecture could help address several of the remaining challenges associated with trace sensitivity, real-time operation, SWaP-C constraints, and environmental robustness summarised in Table 6, while mitigating the corresponding limitations highlighted in Table 2. This should be interpreted as a research direction rather than evidence that these challenges have been solved. Such an integration represents a possible pathway from currently separate demonstrations in the literature toward a deployable LWIR trace detection system, particularly for moving targets if the front end is snapshot and not scanning.
A further underexplored dimension is polarisation. Spectropolarimetric imaging records the polarisation state together with the spectrum, providing information on surface scattering, geometry, and material properties that is not captured directly by conventional spectral intensity measurements [115,116,117]. In explosive-related applications, polarisation has so far been investigated for disturbed soil and surface-laid mines [118,119]. It therefore represents a potentially complementary channel for clutter discrimination, but its contribution to trace residue detection remains to be established.
6. Conclusions
This review set out to answer one question: can an optical sensor detect explosive residues from a safe distance under the conditions that field deployment imposes? To answer it, seven operational requirements were turned into numerical thresholds, standoff distance, trace areal concentration, false alarm rate, acquisition speed, selectivity, environmental operating envelope and moving target capability, and the reviewed studies from 2020 to 2026 were scored against them. The answer is that no reported system demonstrates compliance with all seven. The unmet requirements recur across the reviewed techniques, which suggests that the central barriers arise from shared sensing, environmental and validation constraints and not from a limitation unique to one technique.
The principal finding of this evaluation concerns the architecture of the measurement. The active spectroscopies provide the chemical specificity that detection theory requires of a reliable detector [10]. They obtain it through laser-based measurements that mainly interrogate a point or a line at a time and image only by scanning. Their range, selectivity and safety have not yet been demonstrated within the same experiment. Hyperspectral imaging offers a promising alternative. It provides a particularly flexible route to spatially resolved spectral mapping, recording a contiguous spectrum at every pixel, mapping an area instead of a pre-selected point, and admitting passive operation. Its two branches divide the requirements between them: the passive branch reaches operational standoff [65,66,68,79,108] and checkpoint acquisition speed [79] with bulk loadings far above the trace threshold, and the active long-wave infrared branch reaches the molecular fingerprint and the trace regime only close to the target [58,60], without a detection limit.
The gaps in the evidence follow directly from this scoring. No study reaches standoff and trace sensitivity together, and peroxide-based explosives such as TATP and HMTD remain particularly underexplored. While bulk identification using SWIR spectroscopy has been reported [11], trace-level detection by hyperspectral imaging has not yet been demonstrated, making peroxide detection a significant open challenge for future research. Selectivity against a broad confusant panel and a false alarm rate at a stated operating point are reported by very few. Performance in adverse weather and against a moving target has not been measured by any study in either family of techniques. Independent replication of the reported results is rare, and range and sensitivity are seldom measured in the same experiment. Passive area coverage collects fewer photons per pixel, and that physical limit explains part of the shortfall. The rest reflects how results are reported and not what the instruments can achieve.
Two priorities for the field recur throughout this review. (1) Standardized reporting, so that any deployment claim carries a measured atmospheric transmittance, a declared environmental operating envelope, a detection limit stated against target speed, a false alarm rate tied to a stated decision unit, whether pixel, window, object or inspection, and the accuracy retained after model compression for embedded deployment. (2) A public benchmark of labelled explosive cubes on operational substrates with a fixed confusant panel, without which results from separate groups can be neither compared, reproduced nor aggregated. Neither priority requires new physics. Both would turn the scattered evidence into a record against which the seven requirements can be tested.
A promising instrumental direction lies in the long-wave infrared. An uncooled Fourier-transform front end [71,72] and computational spectral reconstruction [69] have been demonstrated separately. An instrument combining them could operate passively when ambient thermal contrast suffices and actively when it does not and could address the standoff and trace requirements within a single architecture, subject to the feasibility conditions stated in Section 5. Spectropolarimetric imaging offers a complementary channel for clutter discrimination that the explosive literature has so far examined only for disturbed soil and surface-laid mines [115,116,117,118,119]. On the evidence assembled here, standoff explosive detection is waiting less on a new physical effect than on integration, standardized evidence and operational validation.
Author Contributions
Conceptualisation and methodology, A.D. and O.O.; investigation, A.D.; writing—original draft preparation, A.D.; writing—review and editing, O.O., B.D.C., S.L., S.H., F.S., B.S. and R.H.; supervision, O.O., B.D.C., S.L. and R.H. All authors have read and agreed to the published version of the manuscript.
Funding
This research was partially funded by Defence Funded Research (DFR), project number SpectrEx DAP25/13.
Institutional Review Board Statement
Not applicable.
Informed Consent Statement
Not applicable.
Data Availability Statement
No new data were created or analysed in this study. Data sharing is not applicable to this article.
Acknowledgments
During the preparation of this manuscript, the authors used M365 Copilot solely to correct grammar and spelling, improve phrasing, and enhance sentence flow.
Conflicts of Interest
The authors declare no conflicts of interest.
Abbreviations
The following abbreviations are used in this manuscript:
| ACE | Adaptive cosine/coherence estimator | MF | Matched filter |
| AN | Ammonium nitrate | MIL-STD-810H | U.S. Military Standard 810H (environmental test methods) |
| ANFO | Ammonium nitrate/fuel oil | MNF | Minimum-noise fraction |
| ANN | Artificial neural network | MODTRAN | Moderate-resolution atmospheric transmission (radiative-transfer code) |
| ANSI | American National Standards Institute | MSC | Multiplicative scatter correction |
| AOTF | Acousto-optic tunable filter | MWIR | Mid-wave infrared |
| BiLSTM | Bidirectional long short-term memory | N-FINDR | N-finder endmember extraction algorithm |
| CARS | Coherent anti-Stokes Raman scattering | NIR | Near-infrared |
| CEM | Constrained energy minimisation | NIST | National Institute of Standards and Technology |
| CNN | Convolutional neural network | OSP | Orthogonal subspace projection |
| ComDim | Common dimensions analysis | PCA | Principal component analysis |
| CWA | Chemical warfare agent | Probability of detection | |
| DHS–DOJ | U.S. Department of Homeland Security and Department of Justice | PETN | Pentaerythritol tetranitrate |
| DNT | Dinitrotoluene | PLA | Polylactic acid |
| EDS | Explosives detection system | PLS | Partial least squares |
| FAR | False alarm rate | PPV | Positive predictive value |
| FPA | Focal-plane array | PRISMA | Preferred Reporting Items for Systematic Reviews and Meta-Analyses |
| FPGA | Field-programmable gate array | PYX | 2,6-bis(picrylamino)-3,5-dinitropyridine |
| FPI | Fabry–Pérot interferometer | QCL | Quantum cascade laser |
| FT-IR | Fourier-transform infrared | QUAC | Quick atmospheric correction |
| GC–MS | Gas chromatography–mass spectrometry | RDX | Cyclotrimethylene-trinitramine |
| GPU | Graphics processing unit | ResNet | Residual network |
| HgCdTe | Mercury cadmium telluride | ROC | Receiver operating characteristic |
| HMTD | Hexamethylene triperoxide diamine | SAM | Spectral angle mapper |
| HMX | Cyclotetramethylene-tetranitramine | SAR | Synthetic-aperture radar |
| HSD | Hybrid structured detector | SHAP | Shapley additive explanations |
| HSI | Hyperspectral imaging | SNR | Signal-to-noise ratio |
| HybridSN | Hybrid spectral network | SNV | Standard normal variate |
| IEC | International Electrotechnical Commission | SO-PLS | Sequential orthogonalized partial least squares |
| IED | Improvised explosive device | SpectralFormer | Spectral transformer network |
| IFTS | Imaging Fourier-transform spectrometer | SpectralGPT | Spectral generative pretrained transformer |
| ISOFIT | Imaging spectrometer optimal fitting | SUnSAL | Sparse unmixing by variable splitting and augmented Lagrangian |
| IUPAC | International Union of Pure and Applied Chemistry | SVM | Support vector machine |
| JIVE | Joint and individual variances explained | SWaP-C | Size, weight, power and cost |
| KBr | Potassium bromide | SWIR | Short-wave infrared |
| KNN | k-nearest neighbors | TATP | Triacetone triperoxide |
| LC–MS | Liquid chromatography–mass spectrometry | THz | Terahertz |
| LCTF | Liquid-crystal tunable filter | TIR | Thermal infrared |
| LDA | Linear discriminant analysis | TNT | Trinitrotoluene |
| LIBS | Laser-induced breakdown spectroscopy | TSMFTIS | Temporally and spatially modulated imaging FT spectrometer |
| LiDAR | Light detection and ranging | U-Net | U-shaped segmentation network |
| LIF | Laser-induced fluorescence | UAV | Uncrewed aerial vehicle |
| LIME | Local interpretable model-agnostic explanations | UV | Ultraviolet |
| LWIR | Long-wave infrared | UXO | Unexploded ordnance |
| MCT | Mercury cadmium telluride | VIS | Visible |
| MESMA | Multiple-endmember spectral mixture analysis | VNIR | Visible–near-infrared |
| ZnSe | Zinc selenide |
References
- To, K.C.; Ben-Jaber, S.; Parkin, I.P. Recent developments in the field of explosive trace detection. ACS Nano 2020, 14, 10804–10833. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Augustyniak, D.; Szala, M. Field explosives detectors: Current status and development prospects. Sensors 2025, 25, 6024. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Caygill, J.S.; Davis, F.; Higson, S.P.J. Current trends in explosive detection techniques. Talanta 2012, 88, 14–29. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Yin, P.; Xiao, Y.; Feng, C.; Wu, X.; Wang, X.; Klyuyev, D.; Wu, Z.; Zhao, Y.; Hu, B. Decoding complex spectra with machine learning: Advances in spectral unmixing for chemical analysis. Anal. Chem. 2026, 98, 4432–4457. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- U.S. Army National Ground Intelligence Center. IED Safe Standoff Distance Cheat Sheet; NGIC-1122-0091-05; National Ground Intelligence Center: Charlottesville, VA, USA, 2005. [Google Scholar]
- U.S. Department of the Army. ATP 3-21.8: Infantry Platoon and Squad; Appendix D (Security), Checkpoint Procedures; Headquarters, Department of the Army: Washington, DC, USA, 2016. [Google Scholar]
- U.S. Department of the Army. ATP 3-39.30: Security and Mobility Support; Headquarters, Department of the Army: Washington, DC, USA, 2026.
- Wen, P.; Amin, M.; Herzog, W.D.; Kunz, R.R. Key challenges and prospects for optical standoff trace detection of explosives. TrAC Trends Anal. Chem. 2018, 100, 136–144. [Google Scholar] [CrossRef] [Scilit]
- Susiluoto, J.; Bohn, N.; Braverman, A.; Brodrick, P.G.; Carmon, N.; Gunson, M.R.; Nguyen, H.; Thompson, D.R.; Turmon, M. Improved atmospheric correction for remote imaging spectroscopy missions with accelerated optimal estimation. Remote Sens. 2025, 17, 3719. [Google Scholar] [CrossRef] [Scilit]
- Kay, S.M. Fundamentals of Statistical Signal Processing, Volume II: Detection Theory; Prentice Hall: Upper Saddle River, NJ, USA, 1998. [Google Scholar]
- van Damme, I.M.; Mestres-Fitó, P.; Ramaker, H.-J.; Hulsbergen, A.W.C.; van der Heijden, A.E.D.M.; Kranenburg, R.F.; van Asten, A.C. Rapid and on-scene chemical identification of intact explosives with portable near-infrared spectroscopy and multivariate data analysis. Sensors 2023, 23, 3804. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Page, M.J.; McKenzie, J.E.; Bossuyt, P.M.; Boutron, I.; Hoffmann, T.C.; Mulrow, C.D.; Shamseer, L.; Tetzlaff, J.M.; Akl, E.A.; Brennan, S.E.; et al. The PRISMA 2020 statement: An updated guideline for reporting systematic reviews. BMJ 2021, 372, n71. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Verkouteren, J.R. Particle characteristics of trace high explosives: RDX and PETN. J. Forensic Sci. 2007, 52, 335–340. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Verkouteren, J.R.; Coleman, J.L.; Cho, I. Automated mapping of explosives particles in composition C-4 fingerprints. J. Forensic Sci. 2010, 55, 334–340. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Parasuraman, R.; Manzey, D.H. Complacency and bias in human use of automation: An attentional integration. Hum. Factors 2010, 52, 381–410. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Lee, J.D.; See, K.A. Trust in automation: Designing for appropriate reliance. Hum. Factors 2004, 46, 50–80. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- van Eck, N.J.v.; Waltman, L. Software survey: VOSviewer, a computer program for bibliometric mapping. Scientometrics 2010, 84, 523–538. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- U.S. Department of Homeland Security; U.S. Department of Justice. Bomb Threat Stand-Off Card; Digital v2.0; Cybersecurity and Infrastructure Security Agency: Washington, DC, USA, 2020. [Google Scholar]
- Sielicki, P.W.; Stewart, M.G.; Gajewski, T.; Malendowski, M.; Peksa, P.; Al-Rifaie, H.; Studziński, R.; Sumelka, W. Field test and probabilistic analysis of irregular steel debris casualty risks from a person-borne improvised explosive device. Def. Technol. 2021, 17, 1852–1863. [Google Scholar] [CrossRef] [Scilit]
- Viano, D.C. Injury and death to armored passenger-vehicle occupants and ground personnel from explosive shock waves. Sci. Rep. 2023, 13, 2571. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Winder, R.J.; Wilby, S.A.J.; Lessey, L.; Hutson, H.E.; Broome, S.M.; Beardah, M.S. A survey of explosive traces in public places. J. Forensic Sci. 2025, 70, 1450–1459. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Sousa, J.J.; Toscano, P.; Matese, A.; Di Gennaro, S.F.; Berton, A.; Gatti, M.; Poni, S.; Pádua, L.; Hruška, J.; Morais, R.; et al. UAV-based hyperspectral monitoring using push-broom and snapshot sensors: A multisite assessment for precision viticulture applications. Sensors 2022, 22, 6574. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Klapec, D.J.; Czarnopys, G.; Pannuto, J. Interpol review of the analysis and detection of explosives and explosives residues. Forensic Sci. Int. Synerg. 2023, 6, 100298. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Lukow, S.; Weatherall, J.C. Statistical analysis for explosives detection system test and evaluation. Sci. Rep. 2022, 12, 250. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- U.S. Department of Defense. MIL-STD-810H: Environmental Engineering Considerations and Laboratory Tests; Methods 501.7 (High Temperature), 502.7 (Low Temperature) and 507.6 (Humidity); Department of Defense: Washington, DC, USA, 2019. [Google Scholar]
- NATO Standardization Office. STANAG 4370: Environmental Testing; Implemented Through Allied Environmental Conditions and Test Publication AECTP-300: Climatic Environmental Tests; NATO Standardization Office: Brussels, Belgium, 2019. [Google Scholar]
- Bobrovnikov, S.M.; Gorlov, E.V.; Zharkov, V.I.; Murashko, S.N.; Vorozhtsov, A.; Stykon, A. Investigation of the Process of Evolution of Traces of Explosives Carried by Fingerprints Using Polarimetric Macrophotography and Remote LF/LIF Method. Photonics 2023, 10, 740. [Google Scholar] [CrossRef] [Scilit]
- Abdallah, A.; Mahmoud, A.; Mokhtar, M.; Mousa, A.; Ayoub, H.S.; Elbashar, Y.H. Raman spectroscopic and advanced signal processing analyses for real-time standoff detection and identification of explosives. Opt. Quant. Electron. 2022, 54, 265. [Google Scholar] [CrossRef] [Scilit]
- Cantu, L.M.L.; Gallo, E.C.A. Explosives and warfare-agent remote Raman detection on realistic background samples. Eur. Phys. J. Plus 2022, 137, 207. [Google Scholar] [CrossRef] [Scilit]
- Gallo, E.C.A.; Cantu, L.; Duschek, F. Remote Raman spectroscopy of explosive precursors. Opt. Eng. 2021, 60, 084108. [Google Scholar] [CrossRef] [Scilit]
- Bykov, S.V.; Asher, S.A. Standoff deep-ultraviolet Raman spectrometer for trace detection. Appl. Spectrosc. 2024, 78, 227–242. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Hao, R.; Zhao, J.; Liu, J.; You, H.; Fang, J. Remote Raman detection of trace explosives by laser-beam focusing and plasmonic spray enhancement methods. Anal. Chem. 2022, 94, 11230–11237. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Gatti, D.; Lamperti, M.; Zilli, A.; Canella, F.; Cerullo, G.; Galzerano, G.; Laporta, P.; Coluccelli, N. Standoff CARS spectroscopy and imaging using an ytterbium-based laser system. Opt. Express 2022, 30, 15376–15387. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Pfeuffer, K.P.; Le, T.; Dogariu, L.; Zipse, D.; Dogariu, A. Characterization and applications of a fieldable single-laser standoff CARS detection system. Opt. Eng. 2020, 59, 092007. [Google Scholar] [CrossRef] [Scilit]
- Majumder, S.; Gupta, S.; Mathuria, M.K.; Dubey, S.K. Standoff detection of explosives using compressive-sensing-enabled Raman spectral imaging. IEEE Sens. J. 2024, 24, 28094–28099. [Google Scholar] [CrossRef] [Scilit]
- Wild, D.; Theiss, C.; Konstantynovski, K. Fast and safe detection of sensitive explosives via pulsed Raman spectroscopy. Eur. Phys. J. Plus 2025, 140, 737. [Google Scholar] [CrossRef] [Scilit]
- Jiang, X.; Li, Y.; Li, Y.; Shen, C.-Y.; Ozcan, A.; Jarrahi, M. Detection and imaging of chemicals and hidden explosives using terahertz time-domain spectroscopy and deep learning. Light Sci. Appl. 2026, 15, 80. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Periketi, N.; Chaudhary, A.K. Classification of secondary explosives with a 1D convolutional neural network technique using terahertz time-domain spectroscopy in reflection geometry. Spectrochim. Acta A 2026, 346, 126924. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Plekhanov, A.A.; Akmalov, A.E.; Kotkovskii, G.E.; Kozlovskii, K.I.; Kuzishchin, Y.A.; Martynov, I.L.; Maksimov, E.M.; Osipov, E.V.; Chistyakov, A.A. Study of terahertz reflection spectra of optically thin RDX samples by terahertz imaging with spectral resolution. Opt. Eng. 2023, 62, 034109. [Google Scholar] [CrossRef] [Scilit]
- Bratu, A.M.; Bojan, M.; Popa, C.; Petrus, M. Infrared to terahertz identification of chemical substances used for the production of IEDs. Spectrochim. Acta A 2024, 312, 124055. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Maamar, N.; Lazoul, M.; Latreche, F.Y.; Trache, D.; Coutaz, J.-L. Terahertz time-domain spectroscopy characterization of nitrocellulose in transmission and reflection configurations. Optik 2020, 224, 165711. [Google Scholar] [CrossRef] [Scilit]
- Liu, Q.; Zhang, Q.; Li, G.; Guo, Z.; He, X.; Xie, C.; Deng, H.; Shang, L. Terahertz spectral investigation of temperature induced polymorphic transformation of 2,2-dinitroethylene-1,1-diamine. RSC Adv. 2021, 11, 6247–6253. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Koalla, R.; Periketi, N.; Ghorui, C.; Mangali, S.; Chaudhary, A.K. Terahertz time-domain spectroscopy, imaging and density functional theory based studies of 3,4,5-trinitro-1H-pyrazole. J. Mol. Struct. 2022, 1265, 133449. [Google Scholar] [CrossRef] [Scilit]
- Shaik, A.K.; Soma, V.R. Femtosecond filaments for standoff detection of explosives. Def. Sci. J. 2020, 70, 359–365. [Google Scholar] [CrossRef] [Scilit]
- Junjuri, R.; Gummadi, A.P.; Gundawar, M.K. Single-shot compact spectrometer based standoff LIBS configuration for explosive detection using artificial neural networks. Optik 2020, 204, 163946. [Google Scholar] [CrossRef] [Scilit]
- Zhao, Y.; Wang, Q.Q.; Cui, X.; Teng, G.; Wei, K.; Liu, H. Laser-induced breakdown spectroscopy for the discrimination of explosives based on the ReliefF algorithm and support vector machines. Front. Phys. 2021, 9, 675135. [Google Scholar] [CrossRef] [Scilit]
- ANSI Z136.1-2022; American National Standard for Safe Use of Lasers. Laser Institute of America: Orlando, FL, USA, 2022.
- IEC 60825-1:2014; Safety of Laser Products—Part 1: Equipment Classification and Requirements. IEC: Geneva, Switzerland, 2014.
- Bobrovnikov, S.M.; Gorlov, E.V.; Zharkov, V.I. Double-Pulse Laser Fragmentation/Laser-Induced Fluorescence Method for Remote Detection of Traces of Trinitrotoluene. Photonics 2024, 11, 862. [Google Scholar] [CrossRef] [Scilit]
- Bobrovnikov, S.M.; Gorlov, E.V.; Zharkov, V.I. Remote Detection and Visualization of Surface Traces of Nitro-Group-Containing Explosives. Photonics 2024, 11, 1065. [Google Scholar] [CrossRef] [Scilit]
- Bobrovnikov, S.M.; Gorlov, E.V.; Zharkov, V.I.; Panchenko, Y.N.; Puchikin, A.V. Experimental Study of the Dynamics of Laser Fragmentation of Nitrotoluene and Nitrobenzene Vapors. Atmos. Ocean. Opt. 2023, 36, 272–276. [Google Scholar] [CrossRef] [Scilit]
- Bobrovnikov, S.M.; Gorlov, E.V.; Zharkov, V.I.; Murashko, S.N. Two-Pulse Laser Fragmentation/Laser-Induced Fluorescence of Organophosphate Aerosol. Atmos. Ocean. Opt. 2024, 37, 732–737. [Google Scholar] [CrossRef] [Scilit]
- Puchikin, A.V.; Panchenko, Y.N.; Yampolskaya, S.A.; Andreev, M.V.; Prokopiev, V.E. Laser-induced nitrogen oxide fluorescence from nitro compounds by 222 nm laser. J. Lumin. 2023, 263, 120073. [Google Scholar] [CrossRef] [Scilit]
- Paul, M.; Tscheuschner, G.; Herrmann, S.; Weller, M.G. Fast Detection of 2,4,6-Trinitrotoluene (TNT) at ppt Level by a Laser-Induced Immunofluorometric Biosensor. Biosensors 2020, 10, 89. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Elbasuney, S.; Mahmoud, A.; El-Sharkawy, Y.H. Novel molecular laser-induced photoluminscence signature with hyperspectral imaging for instant and remote detection of trace explosive materials. Talanta 2024, 266, 124978. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Koz, A. Ground-based hyperspectral image surveillance systems for explosive detection: Part I, state of the art and challenges. IEEE J. Sel. Top. Appl. Earth Obs. Remote Sens. 2019, 12, 4746–4753. [Google Scholar] [CrossRef] [Scilit]
- Giblin, J.P.; Dupuis, J.R. Longwave infrared spectral reflectance techniques for measuring explosives. In Counterterrorist Detection Techniques of Explosives, 2nd ed.; Elsevier: Amsterdam, The Netherlands, 2022; pp. 253–267. [Google Scholar] [CrossRef] [Scilit]
- Macarthur, J.; Hayden, J.; Warden, M.S.; Carson, C.; Stothard, D.M.; Savitski, V.G. Dual-comb scanning spectrometer for remote sensing of traces of explosives. IEEE Trans. Instrum. Meas. 2022, 71, 7001911. [Google Scholar] [CrossRef] [Scilit]
- Breshike, C.J.; Kendziora, C.A.; Furstenberg, R.; Huffman, T.J.; Nguyen, V.; Budack, N.; Yoon, Y.; McGill, R.A. Hyperspectral imaging using active infrared backscatter spectroscopy for detection of trace explosives. Opt. Eng. 2020, 59, 092009. [Google Scholar] [CrossRef] [Scilit]
- Goyal, A.K.; Wood, D.; Lee, V.; Rollag, J.; Schwarz, P.; Zhu, L.; Santora, G. Laser-based long-wave-infrared hyperspectral imaging system for the standoff detection of trace surface chemicals. Opt. Eng. 2020, 59, 092003. [Google Scholar] [CrossRef] [Scilit]
- Koz, A. Ground-based hyperspectral image surveillance systems for explosive detection: Part II, radiance to reflectance conversions. IEEE J. Sel. Top. Appl. Earth Obs. Remote Sens. 2019, 12, 4754–4765. [Google Scholar] [CrossRef] [Scilit]
- Henriksen, M.B.; Prentice, E.F.; van Hazendonk, C.M.; Sigernes, F.; Johansen, T.A. Do-it-yourself VIS/NIR pushbroom hyperspectral imager with C-mount optics. Opt. Contin. 2022, 1, 427–441. [Google Scholar] [CrossRef] [Scilit]
- Kim, J.-I.; Chi, J.; Masjedi, A.; Flatt, J.E.; Crawford, M.M.; Habib, A.F.; Lee, J.; Kim, H.-C. High-resolution hyperspectral imagery from pushbroom scanners on unmanned aerial systems. Geosci. Data J. 2021, 9, 221–234. [Google Scholar] [CrossRef] [Scilit]
- Hasler, O.; Løvås, H.S.; Oudijk, A.E.; Bryne, T.H.; Johansen, T.A. From do-it-yourself design to discovery: A comprehensive approach to hyperspectral imaging from drones. Remote Sens. 2024, 16, 3202. [Google Scholar] [CrossRef] [Scilit]
- Manley, P.V., II; Via, S.M.; Burken, J.G. UAV-based phytoforensics: Hyperspectral image analysis to remotely detect explosives using maize (Zea mays). Remote Sens. 2025, 17, 385. [Google Scholar] [CrossRef] [Scilit]
- Tuohy, M.; Baur, J.; Steinberg, G.; Pirro, J.; Mitchell, T.; Nikulin, A.; Frucci, J.; de Smet, T.S. Utilizing UAV-based hyperspectral imaging to detect surficial explosive ordnance. Lead. Edge 2023, 42, 98–102. [Google Scholar] [CrossRef] [Scilit]
- Chaudhary, S.; Ninsawat, S.; Nakamura, T. Influence of altitude and image overlap on minimum mapping size of chemical in non-destructive trace detection using hyperspectral remote sensing. Appl. Sci. 2021, 11, 2586. [Google Scholar] [CrossRef] [Scilit]
- Kütük, M.; Geneci, İ.; Özdemir, O.B.; Koz, A.; Esentürk, O.; Yardımcı Çetin, Y.; Alatan, A.A. Ground-based hyperspectral image surveillance system for explosive detection: Methods, experiments, and comparisons. IEEE J. Sel. Top. Appl. Earth Obs. Remote Sens. 2023, 16, 7440–7453. [Google Scholar] [CrossRef] [Scilit]
- Wang, Z.; Yang, Y.; Yuan, L.; Li, C.; Wang, J. Pixel-based long-wave infrared spectral image reconstruction using a hierarchical spectral transformer. Sensors 2024, 24, 7658. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Bajić, M., Jr.; Bajić, M. Modeling and simulation of very high spatial resolution UXOs and landmines in a hyperspectral scene for UAV survey. Remote Sens. 2021, 13, 837. [Google Scholar] [CrossRef] [Scilit]
- Wei, L.; Liao, N.; Wu, W.; Fan, Q. Static Fourier transform long-wave infrared imaging spectrometer based on interferometric supersampling. Opt. Eng. 2024, 63, 083104. [Google Scholar] [CrossRef] [Scilit]
- Corti, M.; Preda, F.; Perri, A.; Ballada, O.; Barta, Č.; Chroust, L.; Gatti, D.; Vesco, G.; Moretti, L.; Valentini, G.; et al. A thermal infrared hyperspectral camera based on a birefringent interferometer. APL Photonics 2025, 10, 101302. [Google Scholar] [CrossRef] [Scilit]
- Norsk Elektro Optikk AS. HySpex Hyperspectral Cameras. Available online: https://www.hyspex.com (accessed on 27 July 2026).
- Telops; Exosens Group. Hyper-Cam Hyperspectral Imaging Cameras. Available online: https://www.exosens.com/brands/telops (accessed on 27 July 2026).
- Sun, Y.; Yang, K.; Liu, J.; Zhang, J.; Zhuo, N.; Liu, J.; Liu, S.; Wang, L.; Liu, F.; Zhai, S. High sensitivity and fast detection system for sensing of explosives and hazardous materials. Sens. Actuators B Chem. 2022, 360, 131640. [Google Scholar] [CrossRef] [Scilit]
- Banas, A.; Banas, K.; Lo, M.K.F.; Kansiz, M.; Kalaiselvi, S.M.P.; Lim, S.K.; Loke, J.; Breese, M.B.H. Detection of high-explosive materials within fingerprints by means of optical-photothermal infrared spectromicroscopy. Anal. Chem. 2020, 92, 9649–9657. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Dreier, L.B.; Kölbl, C.; Jeuk, V.; Beleites, C.; Köhntopp, A.; Duschek, F. Setup and analysis of a mid-infrared stand-off system to detect traces of explosives on fabrics. Sensors 2022, 22, 7839. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Pacheco-Londoño, L.C.; Warren, E.; Galán-Freyle, N.J.; Villarreal-González, R.; Aparicio-Bolaño, J.A.; Ospina-Castro, M.L.; Shih, W.-C.; Hernández-Rivera, S.P. Mid-infrared laser spectroscopy detection and quantification of explosives in soils using multivariate analysis and artificial intelligence. Appl. Sci. 2020, 10, 4178. [Google Scholar] [CrossRef] [Scilit]
- Chen, C.; Xin, J.; Peng, Z.; Wang, C.; Lan, H.; Yao, C.; Wang, J. Stand-off hazardous materials identification based on near-infrared hyperspectral imaging combined with convolutional neural network. Spectrochim. Acta A 2025, 327, 125311. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Mariotti, K.C.; Ortiz, R.S.; Ferrão, M.F. Hyperspectral imaging in forensic science: An overview of major application areas. Sci. Justice 2023, 63, 387–395. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Sharma, M.; Sharma, B.; Gupta, A.K.; Pandey, D. Recent developments of image processing to improve explosive detection methodologies and spectroscopic imaging techniques for explosive and drug detection. Multimed. Tools Appl. 2023, 82, 6849–6865. [Google Scholar] [CrossRef] [Scilit]
- Li, Y.-H.; Tan, X.; Zhang, W.; Jiao, Q.-B.; Xu, Y.-X.; Li, H.; Zou, Y.-B.; Yang, L.; Fang, Y.-P. Research and application of several key techniques in hyperspectral image preprocessing. Front. Plant Sci. 2021, 12, 627865. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Mishra, P.; Biancolillo, A.; Roger, J.M.; Marini, F.; Rutledge, D.N. New data preprocessing trends based on ensemble of multiple preprocessing techniques. TrAC Trends Anal. Chem. 2020, 132, 116045. [Google Scholar] [CrossRef] [Scilit]
- Kurz, W.; Wang, K.; Bektas, F.; Zhu, C.; Kariper, E.; Dong, X.; Kurz, M.; Jakobi, M.; Baranes, D.; Koch, A.W. Dimensionality reduction in hyperspectral imaging using standard deviation-based band selection for efficient classification. Sci. Rep. 2025, 15, 34478. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Ahmad, M.; Shabbir, S.; Roy, S.K.; Hong, D.; Wu, X.; Yao, J.; Khan, A.M.; Mazzara, M.; Distefano, S.; Chanussot, J. Hyperspectral image classification, traditional to deep models: A survey for future prospects. IEEE J. Sel. Top. Appl. Earth Obs. Remote Sens. 2022, 15, 968–999. [Google Scholar] [CrossRef] [Scilit]
- Altamimi, A.; Ben Youssef, B. A systematic review of hardware-accelerated compression of remotely sensed hyperspectral images. Sensors 2022, 22, 263. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Theiler, J.; Ziemann, A.; Matteoli, S.; Diani, M. Spectral variability of remotely sensed target materials: Causes, models, and strategies for mitigation and robust exploitation. IEEE Geosci. Remote Sens. Mag. 2019, 7, 8–30. [Google Scholar] [CrossRef] [Scilit]
- Borsoi, R.A.; Imbiriba, T.; Bermudez, J.C.M.; Richard, C.; Chanussot, J.; Drumetz, L.; Tourneret, J.-Y.; Zare, A.; Jutten, C. Spectral variability in hyperspectral data unmixing: A comprehensive review. IEEE Geosci. Remote Sens. Mag. 2021, 9, 223–270. [Google Scholar] [CrossRef] [Scilit]
- Hong, D.; Gao, L.; Yao, J.; Yokoya, N.; Chanussot, J.; Heiden, U.; Zhang, B. Endmember-guided unmixing network (EGU-Net): A general deep learning framework for self-supervised hyperspectral unmixing. IEEE Trans. Neural Netw. Learn. Syst. 2022, 33, 6518–6531. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Chen, J.; Zhao, M.; Wang, X.; Richard, C.; Rahardja, S. Integration of physics-based and data-driven models for hyperspectral image unmixing: A summary of current methods. IEEE Signal Process. Mag. 2023, 40, 61–74. [Google Scholar] [CrossRef] [Scilit]
- Kendler, S.; Fishbain, B. Crime scene investigation using hyperspectral imaging: Opportunities and challenges. Int. J. Forensic Sci. 2020, 5, 000205. [Google Scholar] [CrossRef] [Scilit]
- Vincent, F.; Besson, O. Robust adaptive target detection in hyperspectral imaging. Signal Process. 2021, 181, 107905. [Google Scholar] [CrossRef] [Scilit]
- Furth, Y.; Rotman, S.R. Efficacy of segmentation for hyperspectral target detection. Sensors 2025, 25, 272. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Mishra, P.; Roger, J.-M.; Jouan-Rimbaud-Bouveresse, D.; Biancolillo, A.; Marini, F.; Nordon, A.; Rutledge, D.N. Recent trends in multi-block data analysis in chemometrics for multi-source data integration. TrAC Trends Anal. Chem. 2021, 137, 116206. [Google Scholar] [CrossRef] [Scilit]
- Song, Y.; Zhang, J.; Liu, Z.; Xu, Y.; Quan, S.; Sun, L.; Bi, J.; Wang, X. Deep learning for hyperspectral image classification: A comprehensive review and future predictions. Inf. Fusion 2025, 123, 103285. [Google Scholar] [CrossRef] [Scilit]
- Roy, S.K.; Krishna, G.; Dubey, S.R.; Chaudhuri, B.B. HybridSN: Exploring 3-D–2-D CNN feature hierarchy for hyperspectral image classification. IEEE Geosci. Remote Sens. Lett. 2020, 17, 277–281. [Google Scholar] [CrossRef] [Scilit]
- Hong, D.; Han, Z.; Yao, J.; Gao, L.; Zhang, B.; Plaza, A.; Chanussot, J. SpectralFormer: Rethinking hyperspectral image classification with transformers. IEEE Trans. Geosci. Remote Sens. 2022, 60, 5518615. [Google Scholar] [CrossRef] [Scilit]
- Roy, S.K.; Deria, A.; Hong, D.; Rasti, B.; Plaza, A.; Chanussot, J. Multimodal fusion transformer for remote sensing image classification. IEEE Trans. Geosci. Remote Sens. 2023, 61, 5515620. [Google Scholar] [CrossRef] [Scilit]
- He, Y.; Tu, B.; Liu, B.; Li, J.; Plaza, A. 3DSS-Mamba: 3D-spectral-spatial Mamba for hyperspectral image classification. IEEE Trans. Geosci. Remote Sens. 2024, 62, 5534216. [Google Scholar] [CrossRef] [Scilit]
- Ahmad, M.; Distefano, S.; Khan, A.M.; Mazzara, M.; Li, C.; Li, H.; Aryal, J.; Ding, Y.; Vivone, G.; Hong, D. A comprehensive survey for hyperspectral image classification: The evolution from conventional to transformers and Mamba models. Neurocomputing 2025, 645, 130428. [Google Scholar] [CrossRef] [Scilit]
- Hong, D.; Zhang, B.; Li, X.; Li, Y.; Li, C.; Yao, J.; Yokoya, N.; Li, H.; Ghamisi, P.; Jia, X.; et al. SpectralGPT: Spectral remote sensing foundation model. IEEE Trans. Pattern Anal. Mach. Intell. 2024, 46, 5227–5244. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Ran, Q.; Zhou, Y.; Hong, D.; Bi, M.; Ni, L.; Li, X.; Ahmad, M. Deep transformer and few-shot learning for hyperspectral image classification. CAAI Trans. Intell. Technol. 2023, 8, 1323–1336. [Google Scholar] [CrossRef] [Scilit]
- Zhao, Y.; Sun, J.; Hu, N.; Zai, C.; Han, Y. Residual channel attention based sample adaptation few-shot learning for hyperspectral image classification. Sci. Rep. 2024, 14, 26746. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Huang, J.; Zhang, Y.; Yang, F.; Chai, L. Attention-guided fusion and classification for hyperspectral and LiDAR data. Remote Sens. 2024, 16, 94. [Google Scholar] [CrossRef] [Scilit]
- Wang, S.; Hou, C.; Chen, Y.; Liu, Z.; Zhang, Z.; Zhang, G. Classification of hyperspectral and LiDAR data using multi-modal transformer cascaded fusion net. Remote Sens. 2023, 15, 4142. [Google Scholar] [CrossRef] [Scilit]
- Kahraman, S.; Bacher, R. A comprehensive review of hyperspectral data fusion with lidar and sar data. Annu. Rev. Control 2021, 51, 236–253. [Google Scholar] [CrossRef] [Scilit]
- Kuras, A.; Brell, M.; Rizzi, J.; Burud, I. Hyperspectral and lidar data applied to the urban land cover machine learning and neural-network-based classification: A review. Remote Sens. 2021, 13, 3393. [Google Scholar] [CrossRef] [Scilit]
- Sun, Y.; Hu, J.; Yuan, D.; Chen, Y.; Liu, Y.; Zhang, Q.; Chen, W. Hyperspectral classification of hazardous materials based on deep learning. Sustainability 2023, 15, 7653. [Google Scholar] [CrossRef] [Scilit]
- Zhao, D.; Yu, P.; Guo, F.; Yang, X.; Ma, Y.; Wang, C.; Li, K.; Chu, W.; Zhang, B. Classification of hyperspectral images of explosive fragments based on spatial–spectral combination. Sensors 2024, 24, 7131. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Lee, G.Y.; Dam, T.; Ferdaus, M.M.; Poenar, D.P.; Duong, V.N. Unlocking the capabilities of explainable few-shot learning in remote sensing. Artif. Intell. Rev. 2024, 57, 169. [Google Scholar] [CrossRef] [Scilit]
- Tang, L.; Yin, Z.; Su, H.; Lyu, W.; Luo, B. WFSS: Weighted fusion of spectral transformer and spatial self-attention for robust hyperspectral image classification against adversarial attacks. Vis. Intell. 2024, 2, 5. [Google Scholar] [CrossRef] [Scilit]
- Chen, Z.; Hao, Y.; Liu, Q.; Liu, Y.; Zhu, M.; Xiao, L. Deep learning for hyperspectral image classification: A critical evaluation via mutation testing. Remote Sens. 2024, 16, 4695. [Google Scholar] [CrossRef] [Scilit]
- Vivoli, E.; Bertini, M.; Capineri, L. Deep learning-based real-time detection of surface landmines using optical imaging. Remote Sens. 2024, 16, 677. [Google Scholar] [CrossRef] [Scilit]
- Yang, R.; Huang, M.; Zhao, W.; Zhang, Z.; Sun, Y.; Qian, L.; Wang, Z. Onboard real-time hyperspectral image processing system design for unmanned aerial vehicles. Sensors 2025, 25, 4822. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Kim, S.; Shin, J.; Kim, S. AS-polRI: Analysis of apparent spectral polarization radiant intensity in the midwave infrared band for man-made object detection. Infrared Phys. Technol. 2022, 127, 104352. [Google Scholar] [CrossRef] [Scilit]
- Sattar, S.; Lapray, P.-J.; Aksas, L.; Foulonneau, A.; Bigué, L. Snapshot spectropolarimetric imaging using a pair of filter array cameras. Opt. Eng. 2022, 61, 043104. [Google Scholar] [CrossRef] [Scilit]
- Li, H.; Mu, T.; Han, F.; Tuniyazi, A.; Wang, W. Snapshot miniature optically replicating and remapping imaging spectropolarimeter (MINI-ORRISp): Design, calibration and performance. Opt. Lasers Eng. 2023, 169, 107717. [Google Scholar] [CrossRef] [Scilit]
- Gurton, K.P.; Felton, M. Remote detection of buried land-mines and IEDs using LWIR polarimetric imaging. Opt. Express 2012, 20, 22344–22359. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Li, S.; Jiao, J.; Wang, C. Research on the detection algorithm of camouflage scattered landmines in vegetation environment based on polarization spectral fusion. IEEE Geosci. Remote Sens. Lett. 2024, 21, 6011305. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.