Abstract
Hysteresis complicates quantitative strain measurement because the electrical output of a flexible sensor depends on loading history as well as current deformation. This review examines reported mechanisms and mitigation strategies in flexible resistive and capacitive strain sensors. Mechanical dissipation, electrical branch separation, and deformation-estimation error are distinguished by their measured quantities and definitions. Physical strategies are grouped by their principal design targets: polymer networks, conductive networks, interfaces, and sensor geometry. Comparisons examine the contributions of material recovery, conducting contacts, strain transfer, and local deformation, together with their interactions in assembled sensors. A smaller hysteresis loop can accompany changes in sensitivity, working range, or baseline, so these properties are considered together. Computational compensation is compared through explicit hysteresis models and learned temporal estimators, relating their memory representations and calibration requirements to sensor behavior. Static calibration remains an option when its error and timing meet application requirements. Wearable and robotic examples connect these comparisons to mounting, readout, and repeated use. The resulting analysis identifies practical trade-offs in design and calibration, and research needs concerning coupled mechanisms, environmental effects, calibration transfer, and long-term stability.
1. Introduction
Flexible strain sensors convert extension into electrical signals for monitoring deformation of the body, garments, and compliant machines [1,2,3,4]. Their deformable sensing elements, including carbon nanotube (CNT) films, crack-based metal films, and silver-nanowire/elastomer composites, generate measurable changes during stretching [5,6,7]. Quantitative motion tracking requires those signals to be converted into strain throughout loading, release, and pauses. For this conversion, sensitivity and extension range describe signal magnitude and coverage, while repeated loading tests establish how consistently the signal represents strain.
Hysteresis makes this conversion difficult because the electrical response depends on previous deformation. A sensor can reach the same length during stretching and return yet produce different readings; conversely, one reading can correspond to different strains. A calibration based only on the current output then assigns a single estimate to an ambiguous input. Delayed recovery shifts the response at reversals, and electrical relaxation during a strain hold can resemble continued motion. Published studies address these effects through two complementary approaches: physical mitigation changes the material or structure to improve the raw electrical response, while computational compensation uses the response and its history to reconstruct deformation [8,9,10,11]. The resulting electrical loops and deformation estimates provide different measures of improvement.
Existing reviews provide the background for assessing these approaches. Broad strain-sensor reviews discuss materials, transduction mechanisms, performance, and applications [1,4], textile and wearable reviews emphasize construction and use [2,3], while printed-sensor reviews focus on manufacturing and architecture [12]. Reviews of low-hysteresis hydrogels and soft materials relate network design to mechanical recovery and device performance [13,14,15]. The modeling literature examines hysteresis representation, identification, and control [16], and studies comparing sensors and estimators connect physical design with computational correction within individual platforms [17,18]. A comparison across these studies can connect a change in material or structure to electrical recovery and then to the error in the reconstructed strain.
This review brings together these findings for flexible resistive and capacitive sensors under tensile deformation. It compares reported physical strategies according to the component or structure being modified and examines how calibration methods use the resulting electrical signals. Within-study comparisons provide evidence on sensitivity, recovery, working range, mounting, and estimation error. The application examples extend this discussion to integrated measurement. The aim is to relate design and calibration choices to the operating conditions examined in the literature, using the reported metric definitions and test configurations to interpret numerical results.
2. Sensor Mechanisms and Hysteresis Characterization
2.1. Origins of History-Dependent Sensor Response
Hysteresis is the dependence of a response on the deformation path as well as the current strain. Engineering tensile strain is ε = (L − L0)/L0, where L is the current gauge length and L0 is its reference length—100% strain corresponds to ε = 1. Mechanical hysteresis is the loading–unloading loop of nominal stress σ against engineering strain, with the closed-loop area representing dissipated energy per reference volume. Electrical hysteresis is the separation between resistance–strain or capacitance–strain branches. Deformation-estimation error is assessed against an independent strain, length, or angle reference. Mechanical dissipation, electrical recovery, and reconstruction accuracy thus describe different stages of the measurement chain [9,10,11].
The electrical role of each component determines how mechanical history enters the signal. In a continuous resistor, resistance R depends on resistivity, conducting-path length, and cross-sectional area. Particulate composites also depend on contact connectivity and interparticle transport. Capacitance C depends on dielectric properties and electrode geometry, with planar, coaxial, and interfacial devices governed by different geometric or interfacial relations [1,19,20,21,22]. A conducting material can, therefore, transmit deformation history directly as an active resistive network or act as an electrode in a geometry-dominated capacitor.
Sensitivity is commonly expressed as a gauge factor (GF), relating the change in normalized electrical output to strain over a specified interval. The normalized output is y = (R − R0)/R0 for resistive sensing or y = (C − C0)/C0 for capacitive sensing, where R0 and C0 are the reference resistance and capacitance. For nonlinear responses, the interval GF can differ from the local slope, making the strain interval and calculation convention essential to interpreting the value [1,20]. Sensitivity determines the available signal amplitude, while loading–unloading measurements reveal its history dependence.
Electrode network effects can also enter capacitive readout. Electrode fragmentation sensors deliberately use strain-dependent electrode resistance within a distributed capacitive measurement, described by an electrical transmission-line model [23]. In other capacitive designs, sufficiently conductive electrodes allow dielectric and geometric changes to dominate [20,21]. Electrical memory then depends on the recovery of the features governing each readout. A dominant crack network changes the contribution of local contacts to resistance [8], whereas a continuous foil structure converts large overall extension into small local metal strain [24]. These architectures can consequently exhibit different electrical hysteresis despite using compliant supporting materials. Mechanical nonlinearity is a further distinction: a nonlinear elastic response can retrace its loading path with no mechanical loop. A reproducible nonlinear electrical response can likewise be inverted when it is strictly monotonic over the operating interval, and hysteresis introduces an additional dependence on loading history.
Jin et al. [19] related resistance history in dense CNT films to changes in nanotube configuration and a projected-length parameter. Their corrected model describes dense films in which contact resistance dominates individual-conductor resistance. For printed Ag–silicone composites, Yuan et al. [18] attributed transient resistance peaks to competing longitudinal contact loss and delayed transverse contact recovery. Contact rearrangement is an identifiable source of electrical memory in these examples. Matrix recovery and layer constraints also influence the timing and extent of contact recovery, linking component-specific behavior to interactions within the assembled sensor.
Matrix properties and integration both influence conducting network recovery. In carbon-black and silver-coated copper-flake composites with 20 vol% filler, changing silicone stiffness altered the response to stretching and repeated loading [25]. Carbon-black composites retained conductivity more consistently across the tested rates and fatigue conditions, while the initially more conductive silver-coated copper-flake composites lost conductivity at high rates and with cycling. Embedded carbon-grease sensors provide a further example of matrix dynamics accompanying electrical-contact recovery [26], and their cyclic and step responses are discussed in Section 3.2.
2.2. Quantifying Hysteresis and Reconstruction Error
A hysteresis value describes the sensor response under a particular loading protocol. Rate dependence modifies the relation between loading history and electrical output. Printed CNT–silicone sensors retain hysteresis at low loading rates and exhibit frequency-dependent sensitivity, while conductive textiles show resistance relaxation during strain holds [10,11]. A graphene-oxide/silver-nanowire/fullerene (GO–AgNW–C60) coating instead exhibits narrower loading–unloading separation at higher stage speeds within the tested range [27]. The direction and magnitude of rate effects, therefore, depend on the device and the interval examined.
Electrical hysteresis is quantified using several measures. Maximum branch separation normalized by the full-scale electrical output gives the largest vertical gap [8]. The hydrogel study instead defines an area-based degree of hysteresis, DH = |AL − AU|/AL, where AL and AU are the areas under the loading and unloading normalized-resistance curves over the same strain interval [28]. Multiplying DH by 100 expresses it as a percentage. Crossing branches allow contributions of opposite sign to cancel in this area difference, making local branch separation important to its interpretation. The time-area capacitance measure compares the stretching and release portions of the capacitance-change–time response, normalized by the stretching area [9]. Its value depends on the integration intervals and loading protocol. Reconstruction error is measured against an independent reference, for example, as root-mean-square error (RMSE) [11]. Dimensionless strain RMSE multiplied by 100 gives strain percentage points. Figure 1 locates these measures along the sensing chain.
Figure 1.
Schematic of hysteresis along the measurement chain. (a) A closed nominal-stress–engineering-strain loop represents dissipated mechanical energy per reference volume. (b) Electrical branch separation can give two strains for the same reading. (c) Reconstructed deformation is evaluated against an independent reference. R: resistance; C: capacitance; ε: engineering tensile strain; σ: nominal stress [8,9,10,11,24,28].
Sensitivity and hysteresis enter inverse calibration differently. For normalized output y, define the local slope magnitude as G = |dy/dε| and the absolute vertical branch separation at a given strain as δy. If the branches are locally monotonic with G > 0, approximately parallel, and only weakly separated, the corresponding strain-axis separation is approximately δε ≈ δy/G.
Illustrative example (hypothetical). Let the reference resistance be R0 = 100 Ω and the local slope of normalized output be G = 2. A 2 Ω loading–unloading gap at the same strain corresponds to δy = 0.02 and, under the local approximation, δε ≈ 0.01. Thus, a measured resistance of 120 Ω could correspond to 10% strain during loading or 11% during unloading. If G increases to 4 while the 2 Ω branch gap remains unchanged, δε falls to 0.005 or 0.5 strain percentage points. The electrical hysteresis has not decreased; only its strain-equivalent ambiguity is smaller.
This local branch ambiguity is not the same as measured reconstruction error, which also depends on the estimator and the independent reference trajectory. Nor does G alone determine a loop-wide area metric: area-based hysteresis summarizes the response over an interval, whereas δy describes branch separation at a particular strain. A design change can alter both G and δy. The comparisons in Section 3, therefore, consider sensitivity, branch separation, and usable strain range together [8,20,24].
2.3. Transient Response and Preconditioning
Relaxation, transient peaks, and cyclic hysteresis affect different aspects of sensing. Mechanical stress relaxation is a change in stress at fixed strain, whereas creep is evolving strain under a maintained load. Electrical relaxation is output drift during a strain hold and can reflect both matrix dynamics and contact rearrangement. Overshoot or shoulder peaks distort reversals, while branch separation affects loading–unloading calibration [8,10,11,18,26]. The loading waveform determines how clearly these features appear. In knitted resistive sensors, stepwise and trapezoidal deformation produced sharp peaks followed by decay, whereas continuous triangular motion partly masked the peaks [29]. Peak amplitudes increased over the tested 2.6–40 cm s−1 velocity range and varied with yarn and knit structure. Cycles with reversals and holds thus reveal recovery processes that continuous motion can obscure.
Preconditioning helps establish a repeatable operating state but can also change calibration. The conducting-polymer hydrogel study used approximately 300 prestretch–release cycles before its long-term cycling test [28]. In an ionic-liquid-modified silicone capacitor, electrical hysteresis decreased during cycling while sensitivity and baseline also changed [9]. Conductive-fabric comparisons, including silicone-encapsulated constructions, found material-dependent hysteresis, relaxation, and nonmonotonic intervals [30], and a printed body-worn textile sensor likewise changed response during its initial cycles [31]. Conditioning is, therefore, evaluated through the subsequent stability of the electrical response and usable strain interval, including both branch separation and calibration drift.
2.4. Classification by Transduction Mechanism
Table 1 groups sensors by electrical readout and the dominant signal-generating process. Resistive sensors use contact networks, continuous electronic paths, or ionic conduction, and capacitive sensors use bulk-dielectric geometry, interfacial contact area, or coupling to electrode resistance [1,4,20,21,22,23,24,28]. These distinctions identify the electrical processes whose recovery affects calibration. Material, form, and fabrication provide additional descriptors: textiles can sense through resistive contacts or capacitive overlap, liquid conductors can act as resistive paths or capacitor electrodes, and hydrogels can carry electronic or ionic current or serve in capacitive structures. For a hybrid device, the dominant readout and its contributing secondary mechanisms together determine the parameters examined in Section 3 and Section 4.
Table 1.
Sensor types organized by readout and dominant transduction mechanism.
For contact-based resistors, filler organization, crack opening, film thickness, and yarn layout determine connectivity and recovery. Continuous solid paths depend on local elastic strain and path geometry, and liquid paths also require containment and wetting. Ionic devices also depend on hydration, ion mobility, encapsulation, electrode effects, and excitation. In capacitors, dielectric recovery and permittivity, electrode compliance, geometry, parasitics, and readout range govern the response. Interfacial designs require a monotonic contact-area change within the available travel, and electrode fragmentation readout additionally depends on excitation frequency and distributed impedance [1,20,21,22,23,24,28,34,35,36,37].
3. Physical Strategies for Hysteresis Mitigation
Section 3.1, Section 3.2, Section 3.3 and Section 3.4 group physical strategies by their principal design target and its contribution to the sensor response. Figure 2 maps polymer recovery (a), conducting contacts (b), interfacial strain transfer (c), and local geometry (d) to these four sections. The central laminate shows how distinct processes interact in an assembled device: bonding influences local strain, which affects network rearrangement and the measured R or C. Section 3.5 and Table 2 bring the four groups together for comparison, and the table identifies the evidence sections and the cited studies.
Figure 2.
Design targets in a flexible strain sensor. Panels (a–d) correspond to Section 3.1, Section 3.2, Section 3.3 and Section 3.4: polymer network recovery, conducting-contact evolution, interfacial strain transfer, and geometric strain redistribution. The panels identify component-specific processes, and the laminate illustrates interactions between them. R and C denote resistance and capacitance [8,9,10,11,20,22,24,28].
3.1. Polymer Network Design
Polymer network design adjusts recovery in dielectrics, supporting matrices, and conducting hydrogels. In ionic-liquid-modified polydimethylsiloxane (IL–PDMS), 30 wt% ionic liquid (IL) increases relative permittivity from 2.36 to 10.88 at 10 kHz. The selected material has 8.45% mechanical hysteresis at 100% strain and 20% s−1, compared with 38.35% for VHB [9]. At 100% maximum strain, time-area electrical hysteresis is 2.20% for the IL–PDMS assembly and 8.83% for VHB at 100% s−1, rising to 4.36% and 20.36%, respectively, at 500% s−1 [9]. The two assemblies also differ in surface treatment and encapsulation. A separate design combines oxidized liquid-metal interdigital electrodes with a silica-reinforced, crosslink-adjusted elastomer, coupling matrix recovery to electrode compliance [38].
The relevant recovery process depends on the electrical role assigned to the composite. Shintake et al. [20] compared resistive and capacitive readouts on a carbon-black-elastomer/silicone platform. Across 50–500% strain, the capacitive GF was 0.83–0.98, compared with 1.62–3.37 for electrode resistance, and capacitance showed less history dependence. The amplitude tests included 30 min rests, with drift and cyclic loops examined separately. This matched comparison links a lower GF to a response governed more strongly by dielectric geometry in the capacitive configuration.
Conducting hydrogels require recovery of both load-bearing and conducting phases. Direct-ink writing and freeze–thaw processing of poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) and poly(vinyl alcohol) (PVA) produce a microphase-semiseparated network. Morphology supports the authors’ interpretation that interlocking restricts detachment and sliding [28]. Increasing PEDOT:PSS content reduces both initial resistance and fracture strain. The selected formulation contains 10 wt% PEDOT:PSS in the combined polymer solids. After silicone encapsulation, its electrical area hysteresis is 0.73 ± 0.27%, 0.95 ± 0.43%, 0.73 ± 0.40%, and 1.44 ± 0.71% at maximum strains of 50%, 100%, 200%, and 300%, respectively (mean ± standard deviation; reported n = 5 per amplitude) [28]. The composition series illustrates the balance between conductivity and extensibility.
Hydrogel networks distribute load bearing and charge transport differently. Calcium-crosslinked alginate/PEDOT:PSS combines mechanical dissipation with small electrical loops, while reprocessing changes network state and signal amplitude [39]. In a polyacrylamide network reinforced by modified super-arborized silica, particle–polymer interactions provide mechanical coupling and LiCl supplies mobile ions, and electrical tests examine extension, stage speed, and a separate 500-cycle test at 100% strain [34]. These architectures combine distinct conduction routes with mechanical recovery: mobile ions carry charge in one, while PEDOT:PSS-rich domains provide electronic conduction in the other. The loading–unloading electrical response shows how each network recovers during sensing.
Hydration, temperature, and load sharing also enter network design. A copolymer hydrogel combines silica reinforcement and salt-related functionality with water retention and low-temperature operation [40]. The study evaluates these environmental properties alongside strain sensing. Highly entangled double-network hydrogels use load sharing and network organization to combine rapid mechanical recovery with robustness [41]. These network-level mechanical results complement the assembled-device electrical measurements in the preceding examples.
These designs alter the material that recovers, but the readout also determines which processes are observed. Song et al. [42] compared DC resistance with impedance measured at 10 kHz in ionically conducting hydrogels: the latter reduced drift and apparent hysteresis while increasing the reported GF. This complements the matched resistive–capacitive comparison [20]: sensitivity and hysteresis can improve together when an interfering electrical contribution is reduced. Polymer design and electrical excitation, therefore, need to be considered together, alongside the working range and recovery of the assembled device.
3.2. Conductive Network Design
Conductive network design regulates the connectivity and recovery of the paths carrying the signal [8,10,27,28,43,44]. Early CNT island-and-gap structures retained conducting bundles between separating regions [5], crack-based metallic films concentrated resistance change at opening and closing contacts [6], and silver-nanowire/elastomer sandwiches used distributed networks [7]. Later designs stabilize these contacts, make a reversible path dominate resistance, or establish a reproducible connected state through preconditioning.
Li et al. [8] formed a successive three-dimensional gold-crack network on a CNT–PDMS layer, using surface relief to localize cracking while connected regions maintained conduction. The gold network was designed to dominate resistance variation, reducing the contribution of less reproducible particle network rearrangement. For the 15 wt% CNT formulation, maximum-separation hysteresis decreased from 14.5% to 2.9% at 60% strain and 60 mm min−1. Gauge factors were 41 over 0–20% strain and 13.16 over 20–60%. The electrical working range was 60%, compared with a separately measured fracture extension of 290%. Applying the architecture to carbon-black and reduced-graphene-oxide composites produced residual electrical hysteresis of approximately 10.9% and 10.7%, respectively, despite unloading overshoot below 1%. The same crack network strategy thus produced formulation-dependent loop recovery.
Bridges between conducting regions preserve continuity as cracks open. A prestretched CNT/Ag-nanowire coating on an electrospun thermoplastic polyurethane (TPU) mat shows nearly overlapping cyclic curves and a sensing range to 171%; its separate endurance test uses 2000 cycles at 20% strain and 2 mm s−1 [43]. An organohydrogel microsphere film uses reversible separation of ionic paths and Ecoflex-assisted reconnection instead [45]. These electronic and ionic architectures both exploit controlled disconnection, but their recoverability depends on different contacts, solvent states, and supporting layers.
Phase organization can define a conducting network without a separate metal crack layer. Deep-eutectic-solvent-induced self-segregation concentrates carbon black within a compliant porous PDMS framework [44]. The main test uses a displacement speed of 1 mm s−1, and operation extends to 100% strain, while separate hold tests reveal residual resistance relaxation. Coating a preformed porous PDMS scaffold with carbon black provides an alternative route, with a reported sensing range to 70%, a relatively linear loading response, and low loop separation [46]. Self-segregation organizes the conductive phase during material formation, and scaffold coating establishes the supporting geometry first. In both cases, electrical recovery depends on how the connected conducting regions follow the porous structure.
In binder-free graphene films on PDMS, thickness controls network connectivity, sensitivity, and usable strain [47]. A 63 nm film gives 5% area-defined hysteresis at 0.6% maximum strain and 0.024% s−1, with limited variation across the tested rates. The 45 nm film is cycled only to 0.4%, compared with 0.6% for thicker films, because larger repeated excursions cause damage. The active film consequently limits the working strain of this sensor.
Microchannels can also define solid conducting paths. Repeated injection and curing of PEDOT:PSS forms an active polymer path whose discontinuities contribute to the resistance response [48]. Loading–unloading tests at 10–30% strain show small but finite electrical hysteresis. In a fluid-filled channel, by comparison, redistribution, channel geometry, and the electrical properties of the liquid govern calibration. The physical state of the conducting phase, therefore, changes how channel confinement affects the signal.
Filler content also affects manufacturing consistency. Lowering CNT concentration in a printable silicone composite increases sensitivity and specimen-to-specimen variation [10]. The authors selected the 0.5 wt% formulation on the basis of consistency and printability, then applied inverse compensation to its residual hysteresis.
Embedded carbon-grease printing forms monolithic extensible sensors within a co-cured silicone reservoir. Five cycles to 100% strain at 2.96 mm s−1 retained substantial electrical hysteresis, and separate faster step tests showed overshoot and relaxation [26]. The authors attributed these transients to carbon-contact disruption and recovery together with elastomer dynamics. This example shows how the response of an embedded conducting path depends on both contact evolution and the surrounding material.
Layer stiffness can control contact recovery by redistributing deformation. Yuan et al. [18] printed a 100 μm Ag–Ecoflex film on a 1 mm PDMS substrate to form an Ag–Ecoflex–PDMS (EAP) assembly. At 72.0 wt% Ag, it showed smaller transverse contraction and weaker shoulder peaks than the Ecoflex-supported assembly, with a GF of 31.3. The dynamic comparison used 40% strain and 10 mm s−1 over a 27 mm gauge (nominally 37.04% s−1). The support and encapsulating elastomer both changed in this comparison. The authors attributed the improvement to coordination of longitudinal contact loss and transverse contact recovery, with the stiffer support limiting contraction of the softer active film. In the carbon-black/silver-coated copper-flake comparison, softer silicone matrices instead maintained conduction more effectively during rapid and repeated extension [25]. The two comparisons vary different parts of the assembly: the supporting layer in the EAP study and the filler-containing matrix in the composite study. Their results, therefore, describe different mechanical configurations.
Shi et al. [27] used fullerene to modify internal motion in a screen-printed GO–AgNW–C60 coating on polyurethane. They proposed that fullerene facilitates sliding between neighboring GO-containing layers—microscopy at matched strains showed fewer and smaller cracks than in the fullerene-free coating. At 0.2 mm s−1, the formulation labeled C60(7) increased the usable strain range from 31% to 62% while retaining a piecewise resistive response. Loading–unloading separation narrowed as stage speed increased from 0.2 to 0.8 mm s−1.
Strain activation can establish the connected state of a liquid-metal network. Stretching gallium droplets on an indium layer ruptures oxide shells and promotes coalescence, changing connectivity when a new maximum strain is reached [49]. Low-hysteresis characterization follows 80% prestretch within the previously experienced range. A separate endurance test used 10,000 cycles at 50% strain. Here, preconditioning modifies the conductive network itself and establishes the state used for subsequent sensing.
The contact-based strategies share a requirement for reproducible reconnection but differ in the motion that produces sensitivity. Figure 3 links three examples to the design sections: interlocked conducting and supporting domains (Figure 3a, Section 3.1), localized crack opening (Figure 3b, Section 3.2), and elastic bending of a continuous conductor (Figure 3c, Section 3.4). The first two retain or restore conducting connections, and the third avoids changing internal contacts, at the cost of a small relative resistance signal in the cited design. Section 3.3 addresses the interfaces transmitting deformation to all three [8,24,28].
Figure 3.
Deformation mechanisms and the corresponding physical strategies. (a) Interlocked conducting and supporting networks: polymer network design (Section 3.1) [28]. (b) Local crack opening with connected conducting regions: conductive network design (Section 3.2) [8]. (c) Global extension converted into in-plane bending and small local metal strain: sensor geometry design (Section 3.4) [24]. Interface design (Section 3.3) determines strain transfer into these structures. Return arrows indicate recovery. PEDOT:PSS: poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate); PVA: poly(vinyl alcohol); CNT: carbon nanotube; PDMS: polydimethylsiloxane. Schematics are not to scale.
3.3. Interface Design
Interface design controls how the sensing layer, electrodes, encapsulation, and substrate transfer deformation and recover together [9,22,24,28,50]. Compliant electrodes can reduce the mechanical constraint added to a laminate. In an Ecoflex sensor containing three liquid-metal–nickel electrodes, the assembled sensor and an equal-sized elastomer control have nearly overlapping tensile-force curves, with a modulus increase of 0.7% [51]. Elastic finite-element comparisons also show lower stress concentration with compliant electrodes. Connecting the outer electrodes additionally reduces capacitance disturbance from an approaching hand relative to a two-electrode control. Its normalized capacitance change, ΔC/C0, reaches approximately 0.7 over 0–90% strain [51]. This configuration combines mechanical compatibility with electric-field confinement, and body mounting also changes its capacitance–strain slope (Section 5.1).
Bonded and mechanically interlocked interfaces provide complementary attachment routes. Wetting and curing connect a CNT–PDMS coating to its PDMS support, while a separate adhesive joins the conducting hydrogel and silicone encapsulation in the PEDOT:PSS/PVA sensor [8,28]. For woven fabric, low-viscosity CNT–silicone paste penetrates the textile gaps before curing, creating mechanical interlocking [10]. Stable attachment supports repeatable strain transfer, although that printed sensor retains electrical hysteresis addressed by inverse compensation.
A deformable dual-network adhesive can couple elastic encapsulation to a viscoelastic capacitive stack, allowing the bonded layers to assist recovery [50]. At 2 Hz and 50% peak strain, the reported dynamic failure interval is 0–0.94% strain for the coordinated assembly and 0–24.81% for the conventional control. The interval denotes the strain region where the signal-derived strain rate deviates by more than 10% from its reference. Bond integrity also contributes to the IL–PDMS laminate’s recovery: cross-sectional extension and peel tests show stable interfaces, with no visible separation at the inspected scale during extension to 200% (Figures S5–S6 in the Supporting Information to Ref. [9]).
Fixed and mobile interfaces can coexist within the same device. The fullerene-containing coating uses internal layer sliding while external bonding transmits deformation from the polyurethane support [27], and hydrogel network interlocking and macroscopic adhesion likewise act at different locations [28]. Xue et al. [22] used this distinction directly in a gradient-stiffness capacitor. Poly(vinyl chloride) (PVC) is bonded to selected PDMS regions, while the Ecoflex/PVC interface slides. Over 0–50% extension, relative layer motion increases electrode–ionic-layer contact area and electric-double-layer (EDL) capacitance. Loading–unloading curves nearly overlap to 50% strain, and a separate endurance test covers 2000 cycles at 40% strain and 2 mm s−1. Stable strain transfer and reversible interfacial motion jointly produce the sensing response.
3.4. Sensor Geometry Design
Sensor geometry converts overall extension into local bending, rotation, electrode separation, or overlap. Origami-inspired mesoscale electrodes rotate within a liquid-filled compartment, producing a capacitance change quantified by area and maximum-deviation measures, which describe different features when loading and unloading branches cross [52]. Kirigami composites instead use cuts and a reinforced skeletal framework to redistribute deformation through the supporting structure [53]. Geometry can, therefore, extend the global working range without imposing the same strain on every sensing component, while introducing constraints from local elastic limits, friction, or available electrode travel.
Interdigital sensors illustrate the influence of electrode spacing and field geometry. Vertically aligned CNT electrodes embedded in PDMS give GFs of 0.637, 0.505, and 0.413 for gaps of 20, 50, and 80 μm, respectively, and larger gaps also give lower reported maximum hysteresis [36]. The gap series, therefore, trades sensitivity against branch separation. In coplanar liquid-metal electrodes, in-plane stretching perpendicular to the electrode fingers increases neighboring-channel separation and decreases capacitance [37], in contrast to the increase in an ideal stretched parallel-plate laminate. Normal-load tests further examine interference in the selected geometry. Electrode compliance, spacing, and field distribution together determine the measured response to deformation.
Coaxial fibers use cylindrical electrode geometry to convert extension into capacitance. Multicore–shell printing alternates ionically conducting fluid and silicone layers [21]. In this geometry, capacitive readout reduces direct sensitivity to fluid-conductivity changes, although water uptake can alter the dimensions. The measured response agreed with the geometric model to 250% strain, and the approximately 700% mechanical extension limit lay beyond the range of the readout electronics. The useful measurement range, therefore, depends on both the fiber geometry and its electrical acquisition.
Dense double-coil fibers use insulated copper wires around an elastic core to convert elongation into changes in coil overlap and separation [54]. Their electrical cycles show low hysteresis despite mechanical hysteresis in the polyester-core assembly. Stretching response is below 30 ms, while release takes approximately 100 ms, which the authors attribute to coil–core friction. The study demonstrates a 0.05% strain step and estimates a theoretical resolution of 0.015%—endurance exceeds 16,000 cycles between 5% and 15% strain.
A continuous constantan/polyimide structure converts global extension into in-plane bending and small local metal strain, avoiding a sensing mechanism based on changing internal contacts [24]. Over eight 0–50% cycles, the sensor gives a repeatability error of 1.58%, a coefficient of determination R2 above 0.999, and a GF of 0.0052. A 0.05% strain step was demonstrated separately. Its low relative signal makes readout resolution important. Encapsulation also affects the installed response: increasing thickness from 0.31 to 1.8 mm reduces the mismatch between freestanding and fully bonded tests from 17% to 2.5%. Mechanical analysis shows that bonding and encapsulation alter local strain and the elastic range. The design, therefore, couples electrical resolution and calibration retention to the local elastic limits of the patterned metal.
Continuous liquid conductors accommodate extension by redistributing the conductive phase. Galinstan patterned on PDMS shows low loading–unloading separation and resolves small increments in a prestretched state [33]. Electrical cycles were reported at 100% strain, endurance at 50% for approximately 8000 cycles and 100 mm min−1, and a separate extension demonstration at 105%. An Ecoflex channel filled with NaCl/propylene glycol uses ionic conduction, with a GF of 6.19 under direct-current (DC) excitation and 3.40 under alternating-current (AC) excitation at 1 kHz [35]. The electrical excitation, therefore, enters calibration alongside fluid composition and channel geometry. Both liquid routes depend on reliable containment and mechanical compatibility with the supporting elastomer. Wave-shaped conducting-solution channels and liquid-metal paths provide an additional geometric variable, accommodating large global extension while limiting distortion of the active channel [55,56].
Textile construction is a geometric design route in which yarn placement and loop shape govern contact evolution. Comparisons of conductive fabrics and encapsulated configurations also show construction-dependent hysteresis, relaxation, and monotonic working intervals [30]. In a 1 × 1 rib knit made at the NP9 knitting-density setting, moving the conductive yarn from outside to inside reduces the strain-axis hysteresis ratio from 0.15 to 0.03 [32]. The test uses a 50 mm gauge length, 30 mm min−1 stage speed, and 40% maximum extension; the working interval changes from 4–32% to 0–40%, changing the ratio’s denominator. An interlock-knit study varied conductive-yarn input tension at fixed elastomer-yarn tension and tested 20 cycles to 40% strain at 120 mm min−1 [57]. Higher input tension produced more stable loop shapes and lower hysteresis. During unloading, recovering contacts lower resistance, while fabric buckling can separate contacts and raise it. Yarn placement and manufacturing tension regulate this competition.
Capacitive textiles assign the conductive structure an electrode role. Batch-fabricated textile–silicone sensors place compliant textile electrodes around a silicone dielectric [58]. The different roles of an active resistive path and a compliant electrode are also evident in the matched-readout comparison [20]. An all-textile overlap capacitor separates an elastic load-bearing region from less extensible electrode panels, so extension drives relative panel motion [59]. The thinner design B gives a more consistently monotonic response, while design A provides greater cyclic stability after initial settling. Designed for subtle movement, these constructions show how electrode travel, spacer behavior, and attachment affect both calibration and durability.
Across these geometries, local elastic strain, fluid containment, contact recovery, and electric-field distribution determine the usable response. Figure 4 compares four capacitive arrangements in which changes in area, thickness, radii, spacing, or interfacial contact produce different capacitance–strain relations [9,21,22,37].
Figure 4.
Geometric transduction in capacitive strain sensors. (a) Planar laminate: C ∝ A/d. The plan views indicate electrode-overlap area A, and the side views show dielectric thickness d between the facing electrode surfaces [9]. (b) Coaxial fiber: C ∝ L/ln(b/a). The axial dimension L is active electrode-overlap length, and the cross-sectional inset identifies inner-electrode outer radius a and outer-electrode inner radius b from the same center [21]. Both relations assume fixed permittivity and ideal geometry. C is capacitance, ∝ denotes proportionality, and ln is the natural logarithm. (c) Coplanar liquid-metal electrodes: in-plane extension perpendicular to the electrode fingers increases channel separation and reduces capacitance [37]. (d) Sliding ionic interface: relative sliding increases electrode–ionic-layer contact area and electric-double-layer (EDL) capacitance within the cited 0–50% working range [22].
3.5. Integration of Physical Strategies
The four design targets affect different parts of the measurement chain: polymer networks set material recovery, conductive networks govern contact evolution, interfaces transfer strain, and geometry distributes local deformation. Parameter series involving film thickness, electrode spacing, or yarn placement illustrate such component-specific effects [32,36,47]. Coupling arises when a change in one part alters the conditions experienced by another. Within the active material, matrix recovery influences contact reconnection and interlocked domains restrict relative sliding [18,28]. Across the assembly, support stiffness, bonding, and encapsulation redistribute local strain [24,50]. At readout, using the same conducting composite as an active resistor or a compliant capacitor electrode changes how its internal history enters the signal [20]. The measured response, therefore, reflects both the selected component and its interactions with the surrounding structure.
One design route stabilizes contacts that generate a large signal, and another reduces reliance on contact rearrangement. Local cracks and recoverable polymer networks retain signal amplification through reproducible reconnection [8,28]. Geometric capacitors and continuous-metal paths emphasize electrode travel, local elastic strain, and readout resolution [21,24,36]. Interface design can assist both routes, including stable external attachment and reversible internal sliding where it generates the signal [22]. Table 2 compares the four groups in one place, with section labels and source citations linking each strategy to its evidence. Recovery, sensitivity, and usable range are evaluated together through the installed output-to-strain relation.
Table 2.
Physical mitigation strategies and their measurement implications.
4. Computational Compensation of Hysteresis
4.1. Principles of Inverse Strain Estimation
Physical mitigation changes the sensor response, whereas computational compensation reconstructs deformation from that response. A forward model predicts electrical output from known deformation, and an inverse estimator uses measured resistance or capacitance to estimate strain, with independent deformation measurements supplying calibration and evaluation references [10,11]. A stable, strictly monotonic response permits a unique static inverse, and small residual branch differences can be accepted when the resulting error meets the task tolerance. History-dependent estimators use previous readings or an updated internal state to distinguish deformation paths that share the same present output. Their effectiveness depends on whether the available signal history resolves those paths. Saturation and inadequate signal resolution can make deformation paths indistinguishable in the recorded signal. Changes in attachment or material state can instead alter the calibrated output–strain relation, even when the signal remains resolvable.
4.2. Explicit Hysteresis Models
Explicit hysteresis models prescribe a memory relation and identify its parameters from calibration data [16]. Operator representations encode reversal memory, and dynamic extensions represent time-dependent recovery. Neural-network-assisted identification of a modified dynamic Preisach model illustrates computational fitting of an explicit memory structure [60]. The examples below compare rate-independent and dynamic inverse representations.
4.2.1. Rate-Independent Inverse Compensation
The modified Prandtl–Ishlinskii (MPI) model combines weighted play operators and a dead-zone transformation to describe asymmetric hysteresis and allow analytical inversion. A play operator retains its output while the input remains within a threshold band around its previous output and updates it when a boundary is crossed; an ensemble of thresholds represents earlier reversals. Lee et al. [10] used 50 play and 10 dead-zone operators for a CNT–silicone composite printed on elastic fabric, calibrated at 20–40% strain and 0.25 Hz. The reported displacement error decreased from 1.61 ± 1.17 mm for a third-order polynomial to 1.05 ± 0.79 mm for MPI. In a one-participant wrist demonstration, MPI also improved stepwise and arbitrary-motion estimates, with a smaller gain for arbitrary movement. Residual errors occur near reversals, where measured speed dependence and local nonmonotonicity complicate the rate-independent approximation. Temperature effects were characterized separately from the wrist calibration.
4.2.2. Rate-Dependent Inverse Compensation
Dynamic inverse models represent the time evolution of hysteresis and relaxation. Oliveri et al. [11] used an asymmetric power-law (APL) model with dynamic hysteretic cells and a nonlinear output transformation to infer Electrolycra strain from resistance. The retained states describe rate-dependent loops and resistance decay during holds. Thirteen datasets covered changed waveforms, nine speeds, and a step-hold test, with five used for identification and eight held out. A 100 mm gauge length and stage speeds of 20–100 mm min−1 correspond to nominal strain rates of 0.33–1.67% s−1. APL and MPI performed similarly when the waveform changed at fixed speed, whereas APL better represented cross-speed loop changes and partly corrected the held-out relaxation response. The benefit of dynamic states was, therefore, most evident during speed changes and holds.
4.3. Learned Temporal Estimators
Learned temporal estimators fit the history-to-deformation relation using electrical sequences and deformation-reference data. Oldfrey et al. [61] used a long short-term memory (LSTM) network with filtered resistance and the numerical gradient of unfiltered resistance to estimate extension in two conductive fabrics and a conductive rubber cord. Webcam-derived length at 30 frames s−1 supplied the reference, with approximately 27,500 calibration samples per sensor. Separately collected tests gave mean absolute errors (MAEs) reported as 19.29%, 10.75%, and 14.49% in the source’s Table 2, below the corresponding linear baselines. The reported preprocessing uses forward–backward filtering (filtfilt), making signal buffering and the timing of preprocessing important when implementing online estimation.
Hannigan et al. [17] compared two resistive fibers and a coaxial capacitive fiber under random 5–15% strain at rates up to 25% s−1, acquired at 55 Hz with 32-sample windows for temporal models and expanding time-series folds. Recurrent neural networks (RNNs) reduced strain RMSE relative to min–max scaling for the resistive fibers, whereas linear regression was selected for the capacitive fiber; tested models did not differ significantly for that fiber. Table 3 give the numerical comparison. Results are means over the last three time-series folds. Scaling parameters came from the final 50 s of the recorded dataset, and 30% of the designated test segment was reserved for RNN early-stopping validation. Because fitted linear regression and min–max scaling were separate comparators, the scaling-to-model improvement includes changes beyond the use of temporal memory.
Table 3.
Within-study comparisons of deformation estimators.
The Ag–Ecoflex–PDMS (EAP) sensor combines coordinated layer design with LSTM calibration [18]. Resistance was acquired at 100 Hz, and interval-selected inputs spanned 1000 original sampling moments, approximately 10 s of history, with 200 hidden units. The 40% stretch–release and ascending–descending step tests showed improved agreement between reconstructed and imposed strain. The authors reported a reduction in relative hysteresis error from 14.4% to 0.1% after calibration. A separate robot demonstration used proportional conversion of the raw resistance, illustrating the use of the improved physical response with a simpler mapping.
A time-delay neural network (TDNN) instead exposes a finite resistance history to a feed-forward estimator. For a conductive-rubber cord, calibration at fourteen rates of 2.7–4.6 mm s−1 and 0–16% strain was followed by separately acquired test trajectories [62]. The reported mean length error was 0.23 mm, compared with 0.55 mm for linear regression. Installation on a soft robotic arm involved prestretching and retraining, linking temporal compensation to the installed sensor configuration.
A carbon-waste/Ecoflex study compared LSTM, gated recurrent unit (GRU), one-dimensional convolutional neural network (1DCNN), and Transformer estimators [63]. Ten cycles provided a 9:1 training/validation split, with five additional cycles from the same specimen for testing. The selected history windows contained 35, 35, 30, and 200 samples, respectively. LSTM, GRU, and Transformer gave lower mean squared error (MSE) than the tested 1DCNN configuration. This comparison varied both network structure and history window, and independent random seeds assessed training variability. Additional Transformer models were trained separately at maximum strains of 25%, 50%, and 75%, using 35 training and 5 test cycles per amplitude.
Operator states, explicit sample windows, recurrent states, and attention weights retain different aspects of electrical history (Figure 5). Table 3 places the study-level comparisons alongside the calibration descriptions above. Length error depends on reference gauge length, MAE, and RMSE weight deviations differently, and normalized percentages depend on the chosen denominator. For uniform extension over a fixed reference length L0, division of length error by L0 gives strain error, and multiplying dimensionless strain RMSE by 100 expresses it in strain percentage points. These conversions retain the underlying error statistic. Comparisons can use a common measured quantity, normalization, trajectories, and data partition, or the baseline tested within each study [10,11,17,18,61,62,63].
Figure 5.
Signal histories used for deformation estimation. The electrical signal s(t) is resistance R or capacitance C at time t, and y in Section 2.1 denotes its normalized form. A static mapping uses the current reading, a finite-window estimator uses recent readings, and a state-based estimator updates a retained state z(t) through an explicit or learned model. TDNN denotes time-delay neural network. These representations can be combined. Independent deformation measurements supply calibration and evaluation references. Online estimation uses information available at the prediction time, with acquisition and preprocessing delays included in the measured response [10,11,17,18,61,62,63].
4.4. Matching Compensation to the Sensor Response
Model selection starts from the residual response after a fitted static calibration. A reproducible monotonic mapping is sufficient when its error and timing meet the task. Repeatable reversal loops with little change across loading speeds motivate a rate-independent inverse, such as MPI; analytical inversion is useful, but nonmonotonic segments and changing recovery rates can violate its assumptions [10]. When speed changes and holds alter the response, explicit dynamic states can describe these effects: APL improved cross-speed reconstruction and partly corrected relaxation in the tested textile, while requiring identification of both loop- and time-dependent behavior [11]. Observed reversal, speed-change, and hold responses establish when a rate-independent approximation is adequate.
Learned estimators fit a history-dependent mapping from calibration sequences that cover the intended operating conditions. A finite window makes the input history explicit, and it can omit effects lasting beyond that window. Recurrent models retain an updated state, making initialization and state handling relevant. Attention-based models reweight the supplied sequence, with sequence length remaining a calibration and implementation choice [17,18,61,62,63]. The reported errors reflect the combination of architecture, input window, and preprocessing used in each study. Comparison on common held-out trajectories, including reversals, holds, the intended rate range, and total processing delay, supports selection among static, explicit-memory, and learned candidates. The evidence in Table 3 and Section 4.2 and Section 4.3 connects these choices to tested sensor responses.
5. Measurement Performance and Sensor Selection
The application studies examine dynamic tracking, measurement after installation, and response changes during repeated use [8,9,10,11,28]. These evaluations use different outputs and references. Section 5.1, Section 5.2 and Section 5.3 review the reported results, followed by their implications for operating conditions and parameter selection in Section 5.4 and Section 5.5.
5.1. Dynamic Tracking Performance
The robotic-hand release experiment shows how electrical recovery enters a system-level outcome. Endpoint capacitance calibration maps a bent and straight human finger to the robotic-hand command. A capacitance that remains elevated during release continues to indicate flexion, delaying the commanded hand opening [9]. The IL–PDMS system released the object 0.04 s after the human hand opened, compared with 0.98 s for VHB. These complete-system delays include acquisition, mapping, control, and mechanical release. Separate laboratory tests at 100% strain gave recovery times of 0.22 s and 4.86 s, including stage motion [9]. The paired laboratory and interaction results show faster electrical recovery alongside faster robotic release.
The EAP study compared knee-motion tracking with an Ecoflex-supported control [18]. Correlations with motion-capture angles were 0.955 and 0.904 for the left and right knees, compared with 0.584 and 0.384 for the Ecoflex-supported control. These coefficients describe waveform agreement. A human–robot ping-pong demonstration used proportional conversion of raw resistance to synchronize the robot with arm motion.
Readout and mounting also influence dynamic performance. In the multicore–shell fiber, a 2 Hz second-order low-pass filter reduced reconstruction error, while the gait demonstration used voltage-decay time because direct capacitance acquisition was noisy [21]. The filter also affects the timing of the processed signal. In the liquid-metal–nickel sensor, connected outer electrodes reduced proximity disturbance, although body mounting changed the capacitance–strain slope [51]. Its reported response bound of less than 0.4 s was obtained at a 5 Hz sampling rate. These results make the acquired quantity, sampling, processing, and installed calibration part of the dynamic sensor specification.
5.2. Performance After System Integration
Deformation reconstruction is evaluated against a reference for the measured quantity. Wrist tests compare estimated angle with motion capture, while textile inverse-model tests examine reconstruction under changed waveforms, speeds, and holds [10,11]. In soft robots, sensor signals can be combined with actuation information and mechanical models. An LSTM uses embedded CNT–PDMS resistance and reactance together with commanded actuator pressure to estimate fingertip position and contact force [64]. Wiener–Hammerstein models combine linear dynamics and static nonlinearity for porous conductive actuators, with performance affected by changes in external load [65]. A multi-hypothesis extended Kalman filter combines branch-specific resistance mappings, commanded pressure, and identified actuation dynamics to estimate bending angle [66]. These configurations use complementary electrical and mechanical information to reconstruct the instrumented body’s state. Their use after integration, therefore, depends on the availability of these additional inputs and on the calibration of the mechanical mapping.
Installation and external load determine the relation between local strain and overall shape. A three-cord robotic arm uses installation-specific retraining and a kinematic mapping from estimated sensor lengths [62]. In a pneumatic finger carrying a PEDOT:PSS/PVA sensor, the resistance–angle relation differs between free motion and object-loaded operation [28]. Calibration must, therefore, account for attachment, load transfer, and the mechanical constraints imposed by the task.
Recognition provides a further use for repeatable sensor signals. A soft gripper carrying the gold-crack sensor achieved a reported fruit-classification accuracy of 96% with an 80/20 training/test split [8]. Here, the outcome is object identification, whereas quantitative motion tracking is evaluated through strain or angle error and responsive interaction through timing. These task-specific measures determine how sensor improvements are assessed after integration.
Combined deformation changes the usable calibration range. A fiber with one central and two helical liquid-metal channels supplies complementary resistance and capacitance signals [67]. Its combined tensile–torsional calibration covers tensile strains up to 50%, a narrower range than its pure-extension capability. Joint motion estimation, therefore, depends on the calibrated combination of deformation components.
5.3. Calibration Stability During Cyclic Use
Cyclic operation can change sensitivity and baseline while the electrical loop narrows. During the IL–PDMS sensor’s endurance test at 100% strain and 200% s−1, sensitivities at cycles 1, 25,347, and 50,740 were 1.07, 1.03, and 1.01, hysteresis decreased from 2.98% to 1.49% and 1.26%, while the minimum relative capacitance changed from −0.51% to −2.70% [9]. The calibrated response thus evolved during continued operation. The PEDOT:PSS/PVA hydrogel maintained a small-area-hysteresis loop after approximately 300 conditioning cycles: over 2000 cycles at 100% strain, hysteresis was 0.94% initially, 0.99% at cycle 1000, and 0.73% in the final cycle [28]. These observations distinguish retention of a small loop from stability of the full calibration.
Assembly and material-state changes introduce further stability constraints. Initial cycling changes the response of a printed body-worn textile sensor before it settles [31]. The all-textile capacitor shows a trade-off between a consistently monotonic response and cyclic stability across its constructions [59], while reprocessing changes the network state of alginate-based conducting gels [39].
Endurance also depends on strain amplitude and architecture. One continuous-metal layout was tested for 20,000 cycles at 50% strain, and another for 100,000 cycles at 25% [24]. The gold-crack endurance test used 7.5% strain at 1 Hz for 20 min, compared with 60% for its principal hysteresis curves [8]. In the EAP study, a 75.2 wt% Ag conductor retained 2891 S cm−1 after 10,000 cycles at 40% strain, compared with 5860 S cm−1 initially [18]. This conductivity result describes the conductor formulation, and the strain-estimation results use the separately characterized sensing configuration. Strain amplitude, formulation, and the measured quantity consequently remain essential descriptors of cyclic performance.
The GO–AgNW–C60 coating further illustrates the interaction between amplitude and attachment. In a 3000-cycle test at 40% strain, peak resistance begins to rise after approximately 2600 cycles. Drift appears earlier in the separate 50% test, where the authors observe partial separation from the polyurethane substrate [27]. Maintaining external strain transfer is, therefore, important even when controlled internal sliding benefits the conducting film.
Continued measurement requires the output-to-deformation mapping to remain within tolerance or to be updated as the sensor changes. Loop separation, baseline, sensitivity, and previous maximum strain all influence that decision [9,28,49]. Optimal-transport adaptation with a TDNN updates a liquid-metal sensor during gait tracking under a stable activity distribution, so changing activity is itself a transfer condition [68]. Figure 6 organizes three complementary comparisons along this measurement chain: (a) how a physical assembly changes electrical recovery, (b) how calibration changes reconstruction error, and (c) how amplitude changes the electrical loop. Together, the panels relate each design or evaluation change to its corresponding measurement outcome.
Figure 6.
Three complementary comparisons in quantitative strain sensing: sensor design, calibration, and operating amplitude. (a) Time-area electrical hysteresis of IL–PDMS and VHB assemblies at 100% maximum strain and two rates; values from Section 3.4, p. 7664, of Ref. [9]. (b) Min–max scaling versus the selected model for two resistive fibers (R-H3078, R-PEU) and a capacitive fiber (C); last-three-fold means from Table 1 and Section 3.5 of Ref. [17]. Selected models are RNNs for the resistive fibers and linear regression for C, and dimensionless strain RMSE is multiplied by 100. (c) Electrical area hysteresis of PEDOT:PSS/PVA at four maximum strains; reported mean ± one standard deviation, n = 5 per amplitude, from Section 2.2, p. 3, of Ref. [28]. Panels retain their own metrics: time-area hysteresis, strain RMSE in percentage points, and strain-loop area hysteresis. Panels (a,b) show point estimates. Numerical values and conditions for (a,c) are given in Section 3.1, and the estimator comparison in (b) is listed in Table 3. H3078: Hytrel 3078; PEU: polyether urethane-urea; IL–PDMS: ionic-liquid-modified polydimethylsiloxane; PEDOT:PSS: poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate); PVA: poly(vinyl alcohol).
5.4. Sensor Selection for Operating Conditions
Table 4 links operating needs to design or calibration choices and the variables to examine. The relevant conditions include strain interval, signal resolution, loading rate, reversals and holds, cyclic history, mounting, and readout. Contact network films, geometric capacitors, and continuous conducting paths differ in how deformation changes their signals [8,9,24,28,47,62]. The section labels in each row point directly to the supporting comparisons and parameter-setting discussion.
Table 4.
Operating needs and the corresponding design checks.
5.5. Parameter Selection and Calibration
Gauge length and mounting establish the mechanical conditions for parameter selection. Under uniform uniaxial extension, nominal engineering strain rate is stage speed divided by reference gauge length: mm s−1 divided by mm gives s−1, and multiplication by 100 gives % s−1. In bonded, curved, or patterned sensors, the local strain distribution additionally depends on geometry and attachment.
Signal resolution depends on the response to the smallest strain change of interest. With normalized output y and local slope magnitude G = |dy/dε|, small increments obey |Δy| ≈ G|Δε| on a specified monotonic calibration branch. For a nonlinear sensor, G varies with operating point and can differ from the interval GF. The same local slope converts a small electrical branch gap into an approximate strain ambiguity, as described in Section 2.2. Signal resolution and hysteresis are, therefore, assessed together, while independent strain-reference measurements determine the total reconstruction error [1,20,24,47].
The vertical-interdigital series illustrates a design-specific trade-off: widening the gap reduces both GF and reported hysteresis [36]. The continuous-metal example shifts the constraint to readout resolution and mounting [24]. With GF = 0.0052, a 0.1% strain increment gives a calculated normalized resistance change of 5.2 × 10−6 over the approximately linear range. Resolving this signal requires suitable noise and drift performance. Increasing encapsulation thickness reduces free/bonded response mismatch but also changes local strain and the elastic range. Together, these results support selection using signal resolution, electrical recovery, and installed calibration.
The IL–PDMS example also separates high-rate recovery from endurance: the former uses rates up to 500% s−1, whereas endurance uses 200% s−1 at 100% peak strain [9]. Both results refer to the complete 30 wt% IL laminate, including electrodes, interfaces, and encapsulation. The resistive layer-coordination study [18] offers a complementary example of assembly-level design for dynamic strain sensing.
For garments, construction controls strain transfer and recovery. Moving conductive yarn from outside to inside a knit changes the strain-axis hysteresis ratio from 0.15 to 0.03 and the working interval from 4–32% to 0–40% [32]. A common target interval, therefore, provides a consistent basis for construction comparisons. Yarn input tension further adjusts contact evolution [57], while overlap capacitors require sufficient electrode travel and stable spacers and attachment [59]. These parameters should accommodate the deformation of the garment at the intended sensing location.
Calibration complexity can be assessed through the reconstruction error and timing obtained with each mapping. A fitted static mapping is sufficient when its error and timing meet the task throughout the required trajectories; repeatable path dependence that exceeds this tolerance motivates inverse or temporal estimation [10,11]. Reversal and hold responses guide history duration and sample spacing, with separate validation sequences used for tuning. Examples include 32-sample windows at 55 Hz and interval-selected inputs spanning approximately 10 s [17,18]. State-based estimators also require a specified initial state or a defined initialization sequence. Installation-specific retraining and activity-dependent adaptation address subsequent changes in use [62,68].
6. Challenges and Research Directions
6.1. Resolving Component Contributions and Coupling
Mechanism-resolving experiments can compare the effect of changing one component with the effect of changing interacting components. The EAP study measures transverse deformation alongside resistance [18], while combined nanomechanical and conductive atomic force microscopy resolves local conducting structures in elastomers under compression [69]. Extending paired structural and electrical observations to tensile reversals and holds, while independently varying matrix, support, or bonding, would identify their individual contributions. Combined variations could then test how one component changes the response associated with another. This approach links the component-specific effects and couplings summarized in Section 3.5.
6.2. Sensitivity–Range–Reproducibility Trade-Offs
The reported parameter series link recovery to other measurement properties. The constantan design combines a small GF with mounting-dependent local strain, PEDOT:PSS content changes conductivity and fracture strain, and particulate loading changes sensitivity and specimen variation [10,24,28]. Joint measurements of signal resolution, usable strain, and cyclic response would clarify these trade-offs after installation. Manufacturing adds variation in deposition, scaffold geometry, and attachment [46,59], and strain activation can also reorganize a liquid-metal network at a new maximum strain [49]. Comparing those changes with calibration error would identify which tolerances require process control and which can be accommodated by calibration.
6.3. Transferable Calibration
Fixed-speed cycles, variable-speed reversals, and holds probe different response histories [10,11]. Temporal estimators also differ in history duration, sample spacing, and retained state [17,18,63]. Future comparisons can use common acquisition settings, trajectories, and deformation references to evaluate fitted static, explicit-memory, and learned estimators. Separating parameter fitting, model selection, and final testing at the sequence level, before constructing history windows, limits overlap between their input samples. Fitting normalization to training data keeps the final test separate from calibration. For online use, the evaluated timing includes acquisition, buffering, filtering, and computation—forward–backward or centered preprocessing adds any waiting time needed for subsequent samples. These controls distinguish model performance from differences in data handling.
Calibration transfer can involve several distinct changes. New trajectories on the same conditioned specimen, a changed amplitude, remounting, a new specimen, and environmental changes each alter the estimation problem. Installation-specific retraining, additional actuation inputs, and adaptation under a stable activity distribution provide existing approaches [62,66,68]. Testing these changes separately would identify when the original mapping remains usable, when a limited update is sufficient, and when new deformation-reference data are needed.
A further question is whether a mechanistic constraint improves estimation beyond an unconstrained model. In an exploratory physics-informed neural network (PINN)–LSTM test on a carbon-filled sensor, a homogeneous-conductor relation brought little improvement (Note 7 in the Supplementary Information to Ref. [63]). Electrode fragmentation capacitors, by contrast, use a distributed electrical model that includes electrode resistance [23]. Comparisons with a fitted static mapping and an unconstrained temporal estimator could test whether an added mechanism-based state or constraint reduces error on new trajectories.
6.4. Environmental Effects on Hysteresis and Calibration
Temperature and moisture affect both mechanical recovery and electrical transport. In hydrogels, solvent loss or uptake changes polymer concentration, dimensions, and ionic pathways, and temperature changes ion mobility and the interactions that govern network or contact recovery. These changes can shift the baseline and slope, alter loading–unloading separation, or combine all three. Water-retaining and anti-freezing designs help stabilize the material state, and their measurement performance can be followed through baseline, slope, loop separation, and reference-based strain error as environmental conditions change [40,45,70].
Recent designs expose different aspects of this problem. The silica-crosslinked copolymer hydrogel combines low electrical hysteresis with water retention and anti-freezing functionality [40]. In the organohydrogel microsphere sensor, measurements from −21 to 80 °C show temperature-dependent sensitivity and a reduced upper strain limit at the highest temperature; the authors relate this to ion mobility, intermolecular interactions, and solvent redistribution [45]. A humidity-adaptive LiBr hydrogel retains small electrical loops during aging under fluctuating relative humidity, yet its GF decreases over prolonged storage [70]. Developed principally as a compliant interconnect, the latter combines low strain sensitivity with electrical continuity. Together, these results separate continued electrical operation, small loop separation, and retention of the original calibration.
Environmental comparisons would be more informative if they measured loading–unloading curves and held recovery after equilibration at the stated temperature and relative humidity, then repeated the same strain histories during exposure changes. Reporting solvent retention or dimensional change alongside baseline, GF, loop definition, and reference-based strain error would distinguish transport drift from altered memory. Encapsulation, humectants, or environmental inputs to calibration can then be evaluated for the response they actually stabilize, including any change in compliance, signal magnitude, or processing requirements.
6.5. Long-Term Calibration Retention
Long-term measurements can determine whether electrical changes lead to an unacceptable strain-estimation error. IL–PDMS and hydrogel tests report different changes in loop separation, baseline, and sensitivity, while strain activation introduces dependence on the previous maximum strain [9,28,49]. Repeating reference-based deformation measurements during endurance tests would connect these changes to calibration retention at the stated amplitude, rate, and conditioning state. Installation and combined loading can be examined separately [62,67]. The duration over which a mapping meets the specified error tolerance, together with the frequency of calibration updates, provides task-dependent measures of long-term performance.
7. Conclusions
Low-hysteresis strain sensing depends on recovery of the structure that generates the measured electrical signal. The reviewed strategies modify polymer recovery, conducting contacts, interfacial strain transfer, or local geometry, and the assembled response also reflects interactions among these components. Contact-based designs can retain large signals through repeatable reconnection. Geometric capacitors and continuous conductors reduce reliance on contact rearrangement while shifting attention to readout resolution, electrode travel, and mounting [8,20,21,22,23,24,28]. External bonding and internal mobility serve distinct functions within the assembly. Sensitivity, electrical branch separation, and usable strain together provide a basis for evaluating each intervention and its integration.
Calibration choice follows the residual response and the task’s error and timing requirements. A fitted static mapping is adequate when those requirements are met. Repeatable branch memory can motivate a rate-independent inverse, whereas rate changes and relaxation require a representation that captures the relevant dynamics. Explicit and learned estimators offer different memory and calibration choices, and their benefit is evaluated against a fitted baseline on comparable trajectories with consistent error definitions [10,11,17,18,61,62,63]. Initialization, available history, and processing delay are part of that comparison.
For wearable and robotic use, the selected response must also survive attachment, repeated loading, and environmental change. A sensor may retain a small loop while its baseline or slope drifts, so endurance and water-retention results need to be connected to strain-reference measurements [9,28,70]. The practical outcome is an installed sensor–calibration combination that resolves the required motion within tolerance. Further progress involves identifying component-specific mechanisms and their interactions, then determining how calibration or sensor configuration should change as material state and mounting evolve.
Author Contributions
Conceptualization, W.S. and C.Z.; literature investigation, W.S., C.Z., H.C. and J.Y.; writing—original draft, W.S. and C.Z.; writing—review and editing, W.S. and C.Z.; supervision and funding acquisition, W.S. and C.Z. All authors have read and agreed to the published version of the manuscript.
Funding
This work was supported by the National Natural Science Foundation of China (grant numbers 52605439 and 51975082).
Institutional Review Board Statement
Not applicable.
Informed Consent Statement
Not applicable.
Data Availability Statement
No new data were created or analyzed in this study. Data sharing is not applicable to this article.
Conflicts of Interest
The authors declare no conflict of interest.
References
- Souri, H.; Banerjee, H.; Jusufi, A.; Radacsi, N.; Stokes, A.A.; Park, I.; Sitti, M.; Amjadi, M. Wearable and Stretchable Strain Sensors: Materials, Sensing Mechanisms, and Applications. Adv. Intell. Syst. 2020, 2, 2000039. [Google Scholar] [CrossRef] [Scilit]
- Jansen, K.M.B. Performance Evaluation of Knitted and Stitched Textile Strain Sensors. Sensors 2020, 20, 7236. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Tabrizi, M.; Gil, I.; Corbalan, M.; Fernández-García, R. Flexible Resistive Sensors for Wearable and Ergonomics Applications: A Systematic Review. Sensors 2026, 26, 2563. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Amjadi, M.; Kyung, K.-U.; Park, I.; Sitti, M. Stretchable, Skin-Mountable, and Wearable Strain Sensors and Their Potential Applications: A Review. Adv. Funct. Mater. 2016, 26, 1678–1698. [Google Scholar] [CrossRef] [Scilit]
- Yamada, T.; Hayamizu, Y.; Yamamoto, Y.; Yomogida, Y.; Izadi-Najafabadi, A.; Futaba, D.N.; Hata, K. A stretchable carbon nanotube strain sensor for human-motion detection. Nat. Nanotechnol. 2011, 6, 296–301. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Kang, D.; Pikhitsa, P.V.; Choi, Y.W.; Lee, C.; Shin, S.S.; Piao, L.; Park, B.; Suh, K.-Y.; Kim, T.-i.; Choi, M. Ultrasensitive mechanical crack-based sensor inspired by the spider sensory system. Nature 2014, 516, 222–226. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Amjadi, M.; Pichitpajongkit, A.; Lee, S.; Ryu, S.; Park, I. Highly Stretchable and Sensitive Strain Sensor Based on Silver Nanowire–Elastomer Nanocomposite. ACS Nano 2014, 8, 5154–5163. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Li, J.; Yao, Z.; Meng, X.; Zhang, X.; Wang, Z.; Wang, J.; Ma, G.; Liu, L.; Zhang, J.; Niu, S.; et al. High-Fidelity, Low-Hysteresis Bionic Flexible Strain Sensors for Soft Machines. ACS Nano 2024, 18, 2520–2530. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Wang, Y.-S.; Zhou, R.-H.; Huang, J.-Y.; Sun, B.-N.; Li, Z.-M.; Chen, Z.-Y.; Song, Z.-Y.; Gao, W.-C.; Pan, C.-F. High-permittivity and low-hysteresis dielectric elastomer for near-free dynamic hysteresis and high-fidelity strain sensors. Rare Met. 2025, 44, 7658–7671. [Google Scholar] [CrossRef] [Scilit]
- Lee, H.; Cho, H.; Kim, S.J.; Kim, Y.; Kim, J. Dispenser printing of piezo-resistive nanocomposite on woven elastic fabric and hysteresis compensation for skin-mountable stretch sensing. Smart Mater. Struct. 2018, 27, 025017. [Google Scholar] [CrossRef] [Scilit]
- Oliveri, A.; Maselli, M.; Lodi, M.; Storace, M.; Cianchetti, M. Model-Based Compensation of Rate-Dependent Hysteresis in a Piezoresistive Strain Sensor. IEEE Trans. Ind. Electron. 2019, 66, 8205–8213. [Google Scholar] [CrossRef] [Scilit]
- Millar, J.; Kent, D.; Alonso-Caneiro, D.; Izhar, U. A Systematic Review of 3D-Printed Flexible Strain Sensors: Materials, Architectures, and Performance. Adv. Sens. Res. 2026, 5, e00167. [Google Scholar] [CrossRef] [Scilit]
- Han, S.; Xing, L.; Qin, Y.; Pan, C. Designing resilient hydrogels: Strategies for minimizing hysteresis while maximizing toughness. Matter 2026, 9, 102489. [Google Scholar] [CrossRef] [Scilit]
- Huang, B.; Lv, Z.; Zhang, M.; Liu, J.; Liu, H.; Li, T.; Fu, L.; Lin, B.; Xu, C. Low mechanical-hysteresis soft materials: Materials, design, and applications. J. Mater. Chem. A 2025, 13, 15427–15452. [Google Scholar] [CrossRef] [Scilit]
- Liu, F.-X.; Jing, X.; Yang, J.; Mi, H.-Y.; Feng, F.-Y.; Liu, Y.-J. Recent progress in low hysteresis gels: Strategies, applications, and challenges. Nano Today 2025, 61, 102601. [Google Scholar] [CrossRef] [Scilit]
- Hassani, V.; Tjahjowidodo, T.; Do, T.N. A survey on hysteresis modeling, identification and control. Mech. Syst. Signal Process. 2014, 49, 209–233. [Google Scholar] [CrossRef] [Scilit]
- Hannigan, B.C.; Cuthbert, T.J.; Geng, W.; Tavassolian, M.; Menon, C. Understanding the Impact of Machine Learning Models on the Performance of Different Flexible Strain Sensor Modalities. Front. Mater. 2021, 8, 639823. [Google Scholar] [CrossRef] [Scilit]
- Yuan, J.; Zhang, Y.; Li, G.; Liu, S.; Zhu, R. Printable and Stretchable Conductive Elastomers for Monitoring Dynamic Strain with High Fidelity. Adv. Funct. Mater. 2022, 32, 2204878. [Google Scholar] [CrossRef] [Scilit]
- Jin, L.; Chortos, A.; Lian, F.; Pop, E.; Linder, C.; Bao, Z.; Cai, W. Microstructural origin of resistance–strain hysteresis in carbon nanotube thin film conductors. Proc. Natl. Acad. Sci. USA 2018, 115, 1986–1991, Correction in Proc. Natl. Acad. Sci. USA 2021, 118, e2103608118. https://doi.org/10.1073/pnas.2103608118. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Shintake, J.; Piskarev, Y.; Jeong, S.H.; Floreano, D. Ultrastretchable Strain Sensors Using Carbon Black-Filled Elastomer Composites and Comparison of Capacitive Versus Resistive Sensors. Adv. Mater. Technol. 2018, 3, 1700284. [Google Scholar] [CrossRef] [Scilit]
- Frutiger, A.; Muth, J.T.; Vogt, D.M.; Mengüç, Y.; Campo, A.; Valentine, A.D.; Walsh, C.J.; Lewis, J.A. Capacitive Soft Strain Sensors via Multicore–Shell Fiber Printing. Adv. Mater. 2015, 27, 2440–2446. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Xue, F.; Peng, Q.; Ding, R.; Li, P.; Zhao, X.; Zheng, H.; Xu, L.; Tang, Z.; Zhang, X.; He, X. Ultra-sensitive, highly linear, and hysteresis-free strain sensors enabled by gradient stiffness sliding strategy. npj Flex. Electron. 2024, 8, 14. [Google Scholar] [CrossRef] [Scilit]
- Nesser, H.; Lubineau, G. Achieving Super Sensitivity in Capacitive Strain Sensing by Electrode Fragmentation. ACS Appl. Mater. Interfaces 2021, 13, 36062–36070. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Li, S.; Liu, G.; Li, R.; Li, Q.; Zhao, Y.; Huang, M.; Zhang, M.; Yin, S.; Zhou, Y.; Tang, H.; et al. Contact-Resistance-Free Stretchable Strain Sensors with High Repeatability and Linearity. ACS Nano 2022, 16, 541–553. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Stier, S.P.; Uhl, D.; Löbmann, P.; Böse, H. Dynamic electro-mechanical analysis of highly conductive particle-elastomer composites. J. Appl. Polym. Sci. 2021, 138, 50377. [Google Scholar] [CrossRef] [Scilit]
- Muth, J.T.; Vogt, D.M.; Truby, R.L.; Mengüç, Y.; Kolesky, D.B.; Wood, R.J.; Lewis, J.A. Embedded 3D Printing of Strain Sensors within Highly Stretchable Elastomers. Adv. Mater. 2014, 26, 6307–6312. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Shi, X.; Liu, S.; Sun, Y.; Liang, J.; Chen, Y. Lowering Internal Friction of 0D–1D–2D Ternary Nanocomposite-Based Strain Sensor by Fullerene to Boost the Sensing Performance. Adv. Funct. Mater. 2018, 28, 1800850. [Google Scholar] [CrossRef] [Scilit]
- Shen, Z.; Zhang, Z.; Zhang, N.; Li, J.; Zhou, P.; Hu, F.; Rong, Y.; Lu, B.; Gu, G. High-Stretchability, Ultralow-Hysteresis Conducting Polymer Hydrogel Strain Sensors for Soft Machines. Adv. Mater. 2022, 34, 2203650. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Oks Junior, A.; Okss, A.; Katashev, A.; Briedis, U. Dynamical Artifacts in Knitted Resistive Strain Sensors: Effects of Conductive Yarns, Knitting Structures, and Loading Rates. Sensors 2026, 26, 2010. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Gamberini, G.; Tognarelli, S.; Menciassi, A. Soft Conductive Textile Sensors: Characterization Methodology and Behavioral Analysis. Sensors 2025, 25, 4448. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Turnbull, R.P.; Corser, J.; Orlando, G.; Venkatraman, P.D.; Yoldi, I.; Bradbury, K.; Reeves, N.D.; Culmer, P. Development of a Body-Worn Textile-Based Strain Sensor: Application to Diabetic Foot Assessment. Sensors 2025, 25, 2057. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Bozali, B.; Ghodrat, S.; Plaude, L.; van Dam, J.J.F.; Jansen, K.M.B. Development of Low Hysteresis, Linear Weft-Knitted Strain Sensors for Smart Textile Applications. Sensors 2022, 22, 7688. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Wu, Y.; Zhou, Y.; Asghar, W.; Liu, Y.; Li, F.; Sun, D.; Hu, C.; Wu, Z.; Shang, J.; Yu, Z.; et al. Liquid Metal-Based Strain Sensor with Ultralow Detection Limit for Human–Machine Interface Applications. Adv. Intell. Syst. 2021, 3, 2000235. [Google Scholar] [CrossRef] [Scilit]
- Han, S.; Tan, H.; Wei, J.; Yuan, H.; Li, S.; Yang, P.; Mi, H.; Liu, C.; Shen, C. Surface Modification of Super Arborized Silica for Flexible and Wearable Ultrafast-Response Strain Sensors with Low Hysteresis. Adv. Sci. 2023, 10, 2301713. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Zhang, H.; Lowe, A.; Kalra, A.; Yu, Y. A Flexible Strain Sensor Based on Embedded Ionic Liquid. Sensors 2021, 21, 5760. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Wang, X.; Deng, Y.; Jiang, P.; Chen, X.; Yu, H. Low-hysteresis, pressure-insensitive, and transparent capacitive strain sensor for human activity monitoring. Microsyst. Nanoeng. 2022, 8, 113. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Zhang, D.; Zhang, J.; Wu, Y.; Xiong, X.; Yang, J.; Dickey, M.D. Liquid Metal Interdigitated Capacitive Strain Sensor with Normal Stress Insensitivity. Adv. Intell. Syst. 2022, 4, 2100201. [Google Scholar] [CrossRef] [Scilit]
- Yang, J.; Tang, H.; Yu, T. Fast-Response, Low-Hysteresis, Anti-Creep Soft Capacitive Strain Sensor Based on Oxidized Liquid Metals and Modified Elastomer. Adv. Mater. Technol. 2026, 11, e02582. [Google Scholar] [CrossRef] [Scilit]
- Shara br Sembiring, Y.; Vo, T.T.; Nurmaulia Entifar, S.A.; Wibowo, A.F.; Kim, J.H.; Ellenahaya Entifar, N.A.; Lee, J.H.; Baek, S.W.; Lee, S.I.; Kim, M.S.; et al. Recyclable, conductive alginate-based hydrogels with high stretchability and low electrical hysteresis for wireless wearable sensors. J. Mater. Chem. A 2025, 13, 15200–15212. [Google Scholar] [CrossRef] [Scilit]
- Zhou, L.; Zhao, B.; Liang, J.; Lu, F.; Yang, W.; Xu, J.; Zheng, J.; Liu, Y.; Wang, R.; Liu, Z. Low hysteresis, water retention, anti-freeze multifunctional hydrogel strain sensor for human–machine interfacing and real-time sign language translation. Mater. Horiz. 2024, 11, 3856–3866. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Zhu, R.; Zhu, D.; Zheng, Z.; Wang, X. Tough double network hydrogels with rapid self-reinforcement and low hysteresis based on highly entangled networks. Nat. Commun. 2024, 15, 1344. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Song, J.; Mou, C.; Balakrishnan, G.; Wang, Y.; Rajagopalan, M.; Schreiner, A.; Naik, D.; Cohen-Karni, T.; Halbreiner, M.S.; Bettinger, C.J. Hysteresis-free and high sensitivity strain sensing of ionically conductive hydrogels. Adv. NanoBiomed Res. 2023, 3, 2200132. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Sun, H.; Fang, X.; Fang, Z.; Zhao, L.; Tian, B.; Verma, P.; Maeda, R.; Jiang, Z. An ultrasensitive and stretchable strain sensor based on a microcrack structure for motion monitoring. Microsyst. Nanoeng. 2022, 8, 111. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Yoshida, A.; Wang, Y.-F.; Sekine, T.; Takeda, Y.; Kumaki, D.; Tokito, S. Printed Low-Hysteresis Stretchable Strain Sensor Based on a Self-Segregating Conductive Composite. ACS Appl. Eng. Mater. 2023, 1, 50–58. [Google Scholar] [CrossRef] [Scilit]
- Zhai, K.; Wang, H.; Ding, Q.; Wu, Z.; Ding, M.; Tao, K.; Yang, B.-R.; Xie, X.; Li, C.; Wu, J. High-Performance Strain Sensors Based on Organohydrogel Microsphere Film for Wearable Human–Computer Interfacing. Adv. Sci. 2023, 10, 2205632. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Xia, Q.; Wang, S.; Zhai, W.; Shao, C.; Xu, L.; Yan, D.; Yang, N.; Dai, K.; Liu, C.; Shen, C. Highly linear and low hysteresis porous strain sensor for wearable electronic skins. Compos. Commun. 2021, 26, 100809. [Google Scholar] [CrossRef] [Scilit]
- Caffrey, E.; Garcia, J.R.; O’Suilleabhain, D.; Gabbett, C.; Carey, T.; Coleman, J.N. Quantifying the Piezoresistive Mechanism in High-Performance Printed Graphene Strain Sensors. ACS Appl. Mater. Interfaces 2022, 14, 7141–7151. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Bhattacharjee, M.; Soni, M.; Escobedo, P.; Dahiya, R. PEDOT:PSS Microchannel-Based Highly Sensitive Stretchable Strain Sensor. Adv. Electron. Mater. 2020, 6, 2000445. [Google Scholar] [CrossRef] [Scilit]
- Park, Y.; Jung, J.; Lee, Y.; Lee, D.; Vlassak, J.J.; Park, Y.-L. Liquid-metal micro-networks with strain-induced conductivity for soft electronics and robotic skin. npj Flex. Electron. 2022, 6, 81. [Google Scholar] [CrossRef] [Scilit]
- He, J.; Huang, J.; Li, R.; Chen, Z.; Li, Z.; Zhou, R.; Wang, S.; Gao, W.; Guo, C.F.; Bao, R.; et al. Hysteresis-free and dynamically resilient strain sensor enabled by interfacial coordination. Sci. Adv. 2026, 12, eaea2450. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Bai, B.; Yang, J.; Yu, T.; Guo, J.; Song, L.; Dong, G. Liquid Metal-Based Capacitive Strain Sensor with Self-Shielding and Low-Hysteresis. ACS Appl. Mater. Interfaces 2025, 17, 44966–44974. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Huang, X.; Liu, L.; Lin, Y.H.; Feng, R.; Shen, Y.; Chang, Y.; Zhao, H. High-stretchability and low-hysteresis strain sensors using origami-inspired 3D mesostructures. Sci. Adv. 2023, 9, eadh9799. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Pongampai, S.; Chaithaweep, K.; Pakawanit, P.; Charoonsuk, T.; Bongkarn, T.; Maluangnont, T.; Vittayakorn, W.; Hajra, S.; Kim, H.J.; Vittayakorn, N. A Kirigami-Engineered “Skeletal Framework” Composite for Ultralow Hysteresis and Highly Stable Strain Sensors. ACS Sustain. Chem. Eng. 2025, 13, 20179–20193. [Google Scholar] [CrossRef] [Scilit]
- Wang, R.; Qiu, T.; Zhang, Y.; Rein, M.; Stolyarov, A.; Zhang, J.; Seidel, G.D.; Johnson, B.N.; Wang, A.; Jia, X. Fiber-Based Miniature Strain Sensor with Fast Response and Low Hysteresis. Adv. Funct. Mater. 2024, 34, 2403918. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Choi, D.Y.; Kim, M.H.; Oh, Y.S.; Jung, S.-H.; Jung, J.H.; Sung, H.J.; Lee, H.W.; Lee, H.M. Highly Stretchable, Hysteresis-Free Ionic Liquid-Based Strain Sensor for Precise Human Motion Monitoring. ACS Appl. Mater. Interfaces 2017, 9, 1770–1780. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Chen, J.; Zhang, J.; Luo, Z.; Zhang, J.; Li, L.; Su, Y.; Gao, X.; Li, Y.; Tang, W.; Cao, C.; et al. Superelastic, Sensitive, and Low Hysteresis Flexible Strain Sensor Based on Wave-Patterned Liquid Metal for Human Activity Monitoring. ACS Appl. Mater. Interfaces 2020, 12, 22200–22211. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Atalay, O.; Kennon, W.R. Knitted Strain Sensors: Impact of Design Parameters on Sensing Properties. Sensors 2014, 14, 4712–4730. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Atalay, A.; Sanchez, V.; Atalay, O.; Vogt, D.M.; Haufe, F.; Wood, R.J.; Walsh, C.J. Batch Fabrication of Customizable Silicone-Textile Composite Capacitive Strain Sensors for Human Motion Tracking. Adv. Mater. Technol. 2017, 2, 1700136. [Google Scholar] [CrossRef] [Scilit]
- AliAbbasi, E.; Freire, R.; Martinez-Missir, V.; Rallabandi, V.; Strohmeier, P. An All-Textile, Mechano-Capacitive Subtle Movement Sensor. Adv. Funct. Mater. 2026, 36, e76802. [Google Scholar] [CrossRef] [Scilit]
- Sunny, M.R.; Kapania, R.K. Artificial-Neural-Network-Based Identification of a Modified Dynamic Preisach Model. Int. J. Comput. Methods Eng. Sci. Mech. 2014, 15, 45–53. [Google Scholar] [CrossRef] [Scilit]
- Oldfrey, B.; Jackson, R.; Smitham, P.; Miodownik, M. A Deep Learning Approach to Non-linearity in Wearable Stretch Sensors. Front. Robot. AI 2019, 6, 27. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Naik, V.; Fairchild, P.; Tan, X. Nonlinear compensation of stretchable strain sensors with application to proprioceptive sensing of soft robotic arm. Smart Mater. Struct. 2025, 34, 035018. [Google Scholar] [CrossRef] [Scilit]
- Li, J.; Yang, H.; Wang, L.; Lai, N.; Sun, C.; Zhou, F.; Liu, Q.; Wang, W.; Li, J.; Hu, C.; et al. Computationally intelligent calibration framework for durable soft strain sensors. Nat. Commun. 2026, 17, 6419. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Thuruthel, T.G.; Shih, B.; Laschi, C.; Tolley, M.T. Soft robot perception using embedded soft sensors and recurrent neural networks. Sci. Robot. 2019, 4, eaav1488. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Willemstein, N.; van der Kooij, H.; Sadeghi, A. 3D-Printed Soft Proprioceptive Graded Porous Actuators with Strain Estimation by System Identification. Adv. Intell. Syst. 2024, 6, 2300890. [Google Scholar] [CrossRef] [Scilit]
- Tan, K.; Ji, Q.; Feng, L.; Törngren, M. Shape Estimation of a 3D Printed Soft Sensor Using Multi-Hypothesis Extended Kalman Filter. IEEE Robot. Autom. Lett. 2022, 7, 8383–8390. [Google Scholar] [CrossRef] [Scilit]
- Li, Z.; Wang, W.; Ji, K.; Wang, C.; Xiong, P.; Du, Z.; Liang, Z.; He, Y.; Xiong, B.; Hou, C. A highly stretchable tri-channel fiber for composite motion decoupling. Nat. Commun. 2026, 17, 7465. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Kim, D.; Kwon, J.; Jeon, B.; Park, Y.-L. Adaptive Calibration of Soft Sensors Using Optimal Transportation Transfer Learning for Mass Production and Long-Term Usage. Adv. Intell. Syst. 2020, 2, 1900178. [Google Scholar] [CrossRef] [Scilit]
- Liang, X.; Liu, H.; Fujinami, S.; Ito, M.; Nakajima, K. Simultaneous Visualization of Microscopic Conductivity and Deformation in Conductive Elastomers. ACS Nano 2024, 18, 3438–3446. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Li, Z.; Wang, Y.; Zhang, Z.; Zhou, J.; Wang, Y.; Li, F.; Hao, Z.; Sun, H. A synergistically designed strain-insensitive conductive hydrogel with humidity-adaptivity supporting sustained functional durability. Mater. Horiz. 2025, 12, 9758–9770. [Google Scholar] [CrossRef] [Scilit] [PubMed]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.