Next Article in Journal
Fluorescence Spectroscopy and Chemometric Modeling for Bioprocess Monitoring
Next Article in Special Issue
A Highly Sensitive Porous Silicon (P-Si)-Based Human Kallikrein 2 (hK2) Immunoassay Platform toward Accurate Diagnosis of Prostate Cancer
Previous Article in Journal
A Data Acquisition Protocol for a Reactive Wireless Sensor Network Monitoring Application
Previous Article in Special Issue
Sensitive, Fast, and Specific Immunoassays for Methyltestosterone Detection
Open AccessArticle

A New Surface Plasmon Resonance Immunosensor for Triazine Pesticide Determination in Bovine Milk: A Comparison with Conventional Amperometric and Screen-Printed Immunodevices

1
Department of Chemistry, Sapienza University of Rome, P. Le Aldo Moro 5, 00185 Rome, Italy
2
Department of Chemistry and Drug Technologies, Sapienza University of Rome, P. Le Aldo Moro 5, 00185 Rome, Italy
*
Authors to whom correspondence should be addressed.
Academic Editor: Alexander Star
Sensors 2015, 15(5), 10255-10270; https://doi.org/10.3390/s150510255
Received: 17 February 2015 / Revised: 3 April 2015 / Accepted: 27 April 2015 / Published: 30 April 2015
(This article belongs to the Special Issue Immunosensors 2014)
A detailed comparison was made of the analytical features of a new Surface Plasmon Resonance (SPR) immunodevice for triazine pesticide determination with those of two other amperometric (conventional and screen-printed) immunosensors and the advantages and disadvantages of the SPR method were thoroughly investigated. For conventional amperometric and screen-printed devices, “competitive” assays were used; conversely, the SPR transduction technique allowed a “direct” measurement format to be used. As far as the main analytical data are concerned, the SPR method does not seem to offer substantial advantages. Nevertheless the measurement time is much shorter and the measurement itself much easier to perform. Lastly several applications and recovery tests were carried out on bovine milk samples, before and after spiking, to check for triazine pesticides in the samples, obtaining satisfactory results. View Full-Text
Keywords: SPR; immunoassay; triazine pesticide analysis; bovine milk SPR; immunoassay; triazine pesticide analysis; bovine milk
Show Figures

Graphical abstract

MDPI and ACS Style

Tomassetti, M.; Martini, E.; Campanella, L.; Favero, G.; Sanzó, G.; Mazzei, F. A New Surface Plasmon Resonance Immunosensor for Triazine Pesticide Determination in Bovine Milk: A Comparison with Conventional Amperometric and Screen-Printed Immunodevices. Sensors 2015, 15, 10255-10270.

Show more citation formats Show less citations formats

Article Access Map by Country/Region

1
Only visits after 24 November 2015 are recorded.