Abstract
Optical-conditioning coatings make clinically difficult dental surfaces measurable by optical scanners, but their role in additive-manufacturing workflows is insufficiently defined. This scoping review links coating formulation and deposition to optical response, scan-mesh geometry, and dimensional verification of patient-specific dental devices. Eighteen in vitro studies identified through PubMed, Scopus, ScienceDirect, and citation searching were included. All 18 included studies underwent full-text QUIN appraisal. Reported film thicknesses ranged from 18.9 to 156 µm, overlapping the nominal scanner-accuracy band and varying with injector design, spray duration, and operator experience. Six studies used 3D-printed models; evidence on metals and ceramics concerned milled or CAD/CAM substrates rather than isolated additively manufactured specimens. No study completed the workflow from coated surface to final printed component and dimensional verification. QUIN scores ranged from 54.2% to 79.2% (mean 62.5%); two studies were low risk and the remainder medium risk. Measured evidence therefore concerns composition, deposition, and scan-mesh or fit outcomes, whereas optical film responses and propagation of coating-induced geometric errors into final devices remain proposed mechanisms. Standardised deposition, optical film characterisation, saliva-conditioned models, and post-print dimensional verification are needed. No included study conditioned substrates with saliva before coating, and no study verified a final additively manufactured device; clinical and device-level implications are therefore provisional.
1. Introduction
Intraoral and laboratory optical scanners have displaced conventional impression workflows across much of restorative dentistry and implant prosthodontics, and their accuracy under controlled conditions is well characterised: benchmark in vitro studies and systematic reviews report trueness values in the tens of micrometres for current systems [1,2,3,4,5,6,7,8,9]. Yet optical measurement presupposes a surface that returns diffuse, well-posed signal, and clinically important surfaces do not: translucent ceramics scatter light below the surface, machined metal reflects it specularly, saliva adds a refracting film, and edentulous spans offer few features for registration [10,11,12]. Since the earliest CEREC systems, the workaround has been to condition the surface with an antiglare agent—titanium-dioxide powders, aerosolised sprays, liquid coatings, or applied markers [13,14].
Within an additive-manufacturing workflow, coating-induced error is not confined to image quality: the coated surface can become the geometry of a digital model used to design and manufacture a patient-specific device. A uniform film may introduce an approximately constant surface offset, whereas uneven deposition, uncoated windows, or local agglomeration may introduce non-uniform shape error into the scan mesh. If that mesh is used for a printed model, crown or framework pattern, surgical guide, custom tray, or other device, the error can propagate into seating, occlusion, marginal adaptation, or fit. Removing the coating after scanning does not remove error already embedded in the digital model. This propagation pathway is a geometric inference: the included studies measured film thickness, scan deviations, or fit outcomes, but reported fit outcomes only for milled crowns rather than additively manufactured parts [15], and no study manufactured and dimensionally verified final additively manufactured devices from coated scans.
The prosthodontic literature has characterised this practice in product terms. Agents are compared by the accuracy values their use produces, a scanner is declared to work “with” or “without” powder, and interventions are treated as interchangeable members of a single category of “scanning aid” on the basis of a shared endpoint [16,17,18]. This framing has been productive, but it is descriptive rather than mechanistic. It establishes that coated surfaces scan differently without explaining what a coating does to the light, and it cannot accommodate findings that the same powder improves one scanner’s accuracy, leaves another’s unchanged, and reverses ranking between systems [19,20].
Surface and optical science address precisely these questions, though the literature on each rarely meets. The scattering efficiency of particulate white pigments is a solved problem of Mie theory, with a characteristic optimum near a quarter-micrometre for rutile TiO2 [21,22,23]. The conversion of a specular surface into a diffuse reflector is described by bidirectional reflectance models [24,25], and the failure of triangulation in translucent media by subsurface-transport models [26]. The error budget of triangulation, confocal, and structured-light measurement is formalised in the optical-metrology literature [27,28,29,30]. What is missing is a mapping between these mechanisms and the dental evidence.
Three important gaps follow. First, the relationship between coating application and scanning accuracy has largely been described as a product-level association, with limited integration of the optical and interfacial events that may link surface chemistry to measurement error. Second, antiglare strategies have generally been compared according to reported accuracy, although chemically distinct interventions may act at different stages of the measurement chain. Third, the prevailing experimental model examines coatings on dry, clean substrates, whereas clinical surfaces are saliva-wet, and wetting may alter both the substrate optics and the coating itself. These gaps limit mechanistic interpretation and reduce the translational relevance of the existing evidence.
Accordingly, this review centres antiglare and optical-conditioning coatings within digital and additive-manufacturing workflows for patient-specific dental devices. It maps the available in vitro evidence against an optical–interfacial framework and distinguishes measured findings from proposed mechanisms. Four aims follow: first, to examine how coating application affects optical three-dimensional measurement and the geometry of digital models; second, to synthesise evidence on printed models and on metal and ceramic substrates while identifying gaps for additively manufactured metals and ceramics; third, to connect formulation, deposition, optical response, and dimensional verification; and fourth, to define the measurements required to establish whether coating-induced scan error propagates into final printed components.
2. Materials and Methods
2.1. Protocol and Reporting
This review was conducted in accordance with the methodological framework for scoping reviews proposed by Arksey and O’Malley [31] and reported according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR) [32,33]. The completed PRISMA-ScR checklist is provided as Supplementary Table S2. The review used a predefined protocol covering eligibility, data charting, and critical appraisal. This is a scoping review with a systematic search and reproducible eligibility and critical-appraisal procedures; QUIN scores were used to contextualise the evidence and not to exclude studies. The protocol was not registered in a public registry; as a scoping review, it is ineligible for PROSPERO registration, and the predefined protocol is instead documented through the eligibility criteria, search strings (Supplementary Table S3), and appraisal procedures reported here and in the Supplementary Materials.
2.2. Review Question and Conceptual Framework
The review question was structured using the Population–Concept–Context framework. The population comprised dental hard and restorative substrates and reference models used in digital and additive-manufacturing workflows, including printed models and polymer, metal, and ceramic restorative substrates; the concept was application of an antiglare or optical-conditioning coating and the resulting surface–light interaction; and the context was optical three-dimensional measurement and dimensional verification under in vitro conditions. The question addressed was: how do coating formulation and deposition influence optical response and the dimensional accuracy of digital models used in additive-manufacturing workflows, and which downstream effects on patient-specific devices are measured rather than proposed?
Findings are mapped onto a six-stage measurement cascade (Figure 1): (1) substrate optical statereflectance, translucency, gloss, and topography of the unscanned surface; (2) coating deposition—spray/fluid dynamics, particle loading, and film thickness; (3) interfacial film, chemistry particle–substrate adhesion, solvent carrier, and residue; (4) light–matter interaction—Mie scattering, BRDF modification, and suppression of specular glare and subsurface scattering; (5) signal acquisition—sensor response of the triangulation, confocal, or active-wavefront imaging chain; and (6) reconstruction, and registration point-cloud generation, stitching, and the resulting trueness and precision error.
Figure 1.
Optical-conditioning cascade within additive-manufacturing workflows. The figure illustrates six stages through which optical conditioning of a deposited film may influence geometric accuracy in a patient-specific device. Solid blue boxes represent the six optical-conditioning and measurement stages, including the relevant variables and control or verification measures. Green boxes identify the intervention classes and the stages in which they are applied. In the lower additive-manufacturing workflow, grey boxes represent measured outcomes (the coated surface and scan mesh, STL), whereas amber boxes indicate the proposed propagation of geometric error into device design and the printed patient-specific device, followed by the required dimensional verification. The red-outlined box summarizes the geometric interpretation and highlights the limitation that final-device error propagation was not experimentally assessed in the included studies. Uniform films may introduce a surface offset, whereas non-uniform films may produce localized shape errors. Arrows indicate the sequence of stages and the potential pathway of error propagation. The proposed propagation to the final device remains a conceptual pathway rather than a demonstrated outcome.
2.3. Information Sources and Search Strategy
Three electronic databases were searched: PubMed (National Library of Medicine, Bethesda, MD, USA), Scopus (Elsevier, Amsterdam, The Netherlands), and ScienceDirect (Elsevier, Amsterdam, The Netherlands). The final searches were conducted on 20 October 2026. No publication-year, date-range, language, publication-type, or study-design filters were applied at the search stage. Reference lists of all included articles were hand-searched for additional eligible records.
Search terms combined controlled vocabulary and free-text terms across three concept blocks, joined with the Boolean operator AND, with terms within each block joined by OR.
- Block 1 (intervention): “scanning spray”, “scan spray”, “scanning powder”, “scanning aid”, “antiglare”, “anti-glare”, “optical conditioning”, “scanning fluid”, “titanium dioxide”, “TiO2”, “matting agent”, “fiducial marker”, powdering
- Block 2 (device/context): “intraoral scanner”, “intra-oral scanner”, “digital impression”, “optical impression”, “CAD/CAM”, “model scanner”, “laboratory scanner”, “desktop scanner”, digitiz*
- Block 3 (outcome): accuracy, trueness, precision, deviation, “measurement error”, “scanning error”, reproducibility
The complete search strings as executed in each database are reproduced in Supplementary Table S3, provided with Tables S1, S2, and S4 in the accompanying Supplementary Materials file.
2.4. Eligibility Criteria
Studies were eligible for inclusion if they met all of the following criteria:
- (i)
- Primary in vitro investigation;
- (ii)
- Application of an antiglare or optical-conditioning agent—scanning powder, aerosol spray, liquid-type scanning aid, or applied fiducial/coating marker to a dental substrate (tooth, die, or restorative material);
- (iii)
- Reporting at least one of the following quantitative outcomes: (a) a three-dimensional measurement outcome (e.g., trueness, precision, deviation, or point-cloud/mesh metrics) obtained using an optical dental scanner; (b) a direct quantitative measurement of the deposited coating (e.g., film thickness or homogeneity); or (c) a quantitative downstream dimensional outcome (e.g., marginal or internal fit of a fabricated restoration);
- (iv)
- Publication in English as a full research report in a peer-reviewed journal, a peer-reviewed journal supplement, or peer-reviewed conference proceedings.
Studies were excluded if they met any of the following criteria:
- (i)
- Narrative or systematic reviews, conference abstracts, case reports, editorials, or letters;
- (ii)
- Evaluation of surface-condition variables without an applied coating (e.g., ambient light, substrate translucency, or wetness alone)—such studies were recorded and reassigned to the interpretive framework (Arm B);
- (iii)
- Reporting of qualitative or purely descriptive outcomes without quantification;
- (iv)
- Evaluation of non-dental industrial metrology systems, which informed the framework only; and
- (v)
- In vivo or clinical study designs, which were recorded during screening but not carried forward, since the review was concerned with mechanistic evidence obtained under controlled conditions.
2.5. Study Selection
Records retrieved from all three databases were exported to a reference manager and deduplicated. Titles and abstracts were screened against the eligibility criteria by two reviewers working independently, and full texts of all potentially eligible records were then retrieved and assessed. Disagreements were resolved through discussion, and where consensus could not be reached, a third reviewer was consulted. Reasons for exclusion at the full-text stage were recorded and are reported in Figure 2. Records identified through citation searching (reference-list screening of the included articles) were retrieved after the database search, verified against the same eligibility criteria, and appraised with the same procedures; these three records are labelled H1–H3 throughout and are shown separately in Figure 2. One eligible record (A2 [15]) was retrievable only as an abstract during the initial review phase despite institutional and inter-library requests; its full text was obtained during revision and was screened and appraised with the same procedure.
Figure 2.
PRISMA 2020 flow diagram of study identification, screening, and inclusion. The solid-bordered pathway represents Arm A, the systematic in vitro evidence arm, including database and citation searching, screening, full-text eligibility assessment, and study inclusion. Light-blue boxes indicate records identified or screened, pale-yellow boxes indicate the full-text eligibility stage, light-green boxes indicate included studies, and light-grey boxes indicate records excluded or not advanced to the next stage. Solid boxes and arrows denote the systematic record flow in Arm A. The dashed-bordered box and dashed arrow represent Arm B, the targeted mechanistic and optical-theory literature used to inform the interpretation of the findings; this literature was not systematically screened or appraised using the QUIN tool. The diagram reports 148 records identified through databases, 23 duplicate records removed, 125 records screened, 19 full-text articles assessed for eligibility, and 15 database studies included. Three additional studies were identified through citation searching, resulting in 18 studies included in the qualitative synthesis; all 18 full texts underwent QUIN appraisal. The full text of A2 was obtained during revision and appraised with the same procedure.
2.6. Data Charting
A data charting form was developed a priori and piloted on two included studies before application to the full set. Variables extracted from each included study: first author and year; country; study design; scanner(s) evaluated, including manufacturer and imaging principle (triangulation, confocal, active wavefront sampling, structured light); software version; antiglare agent evaluated, including commercial designation, manufacturer, and declared composition; application protocol (spray distance, duration, drying time, operator); reported coating thickness or film characterisation, where available; substrate material and geometry; reference measurement method (coordinate measuring machine, industrial scanner, or reference dataset); outcome measure and unit; number of specimens and scan repetitions; environmental conditions (ambient light, humidity); principal quantitative findings with associated statistical significance; and stated limitations. Charting was performed by two reviewers and verified by a third. Where a required datum was not reported, this was recorded as “not stated” rather than inferred. The flow of records through identification, screening, and inclusion is summarised in Figure 2. For the additive-manufacturing synthesis, the manufacturing route of each substrate or model and the level of dimensional verification were additionally mapped from the charted substrate and outcome data. Verification was classified as scan-mesh accuracy, a downstream fit outcome, or direct measurement of a final manufactured component.
2.7. Critical Appraisal of Individual Sources of Evidence
Methodological quality was appraised using the QUIN tool [34], with the twelve criteria scored as adequately specified (2), inadequately specified (1), or not specified (0); not-applicable criteria were excluded from the denominator. Scores were expressed as percentages: >70% low risk of bias, 50–70% medium, <50% high. The QUIN tool was selected because it was developed and validated specifically for the appraisal of in vitro studies in dentistry [34]; the percentage bands were prespecified by the review team as operational categories for descriptive stratification, because the QUIN publication defines no validated risk thresholds (a limitation considered in Section 5). Appraisal was performed on all 18 full texts: the full text of A2 [15], initially available only as an abstract, was obtained during revision and scored with the same procedure. Operator training or proficiency was credited when explicitly reported. Per-criterion scores and the textual basis for each judgement are reported in Supplementary Table S1. No study was excluded on the basis of its appraisal score; the appraisal was used to contextualise the synthesis rather than to weight it.
2.8. Synthesis of Results
Outcomes were synthesised narratively. Quantitative pooling was not attempted because the included studies reported non-commensurable outcome measures (root-mean-square deviation, mean absolute deviation, 90/10 percentile distance, colour-map metrics) obtained with different scanners, reference methods, and alignment algorithms. Findings were charted against the six-stage measurement cascade described in Section 2.2 and are presented by cascade stage rather than by product class. Where studies reported discordant results, findings are reported per scanner, metric, and outcome definition rather than pooled; non-significant results are reported as “no statistically significant difference was detected” and are not treated as evidence of equivalence.
2.9. Identification of the Mechanistic Framework
Because the objective was mechanistic interpretation rather than effect estimation, the charted findings were mapped onto an optical–interfacial framework assembled from the wider surface-science and optical-metrology literature. Publications supporting this framework were identified by targeted searching across six domains: (i) Mie scattering and pigment optics, including TiO2 particle-size effects; (ii) thin-film formation and particle–substrate interfacial adhesion; (iii) surface energy, wetting, and solvent-carrier dynamics; (iv) bidirectional reflectance, gloss, and subsurface scattering; (v) triangulation, confocal, and structured-light measurement theory; and (vi) the optical properties of dental substrates, including enamel translucency and metallic specularity. These publications were selected on the basis of mechanistic relevance and were not subject to the systematic screening or appraisal procedures applied to the primary evidence base (Arm A vs. Arm B, Figure 2).
3. Results
3.1. Study Selection and the Measurement Cascade
The three database searches retrieved 148 records: 35 from PubMed, 62 from Scopus, and 51 from ScienceDirect. After removal of 23 duplicates, 125 unique records remained for title and abstract screening. Nineteen reports were assessed at full text; four were excluded (non-English publication, registration hardware rather than a surface coating, non-dental metrology, and a biological outcome), and citation chasing of the included studies and seed reviews identified three additional eligible reports. Eighteen in vitro studies met all eligibility criteria and were included in the review (Figure 2; study characteristics in Table 1). These evaluated aerosolised scan sprays, powder-based scanning aids, liquid-type scanning aids, a recycled zirconia-dust coating, and applied fiducial or composite markers, tested on prepared teeth, full-arch and edentulous typodonts, metallic reference models, implant frameworks, and post-space models, against reference measurements from laboratory scanners, industrial blue-light scanners, design data, and measuring microscopes. The full text of one study (A2 [15]), initially available only as an abstract, was obtained during revision; all eighteen studies were appraised in full.
Seventeen of the eighteen studies reported specimen or repetition numbers; sample sizes ranged from five to twenty per group, with ten scans per condition the most frequent design. Only two studies reported an a priori sample size calculation [35,36]; a further two stated that sample sizes were replicated from previous literature [37,38].
Figure 1 sets out the six-stage measurement cascade against which these studies are interpreted: (1) substrate optical state; (2) coating deposition; (3) interfacial film chemistry; (4) light–matter interaction; (5) signal acquisition; and (6) reconstruction and registration. As in other evidence bases mapped onto multi-stage cascades, the included studies address only a subset of the stages, and none addresses all six.
Table 1.
Characteristics of the 18 included in vitro studies (Arm A). All studies used in vitro comparative or factorial designs. QUIN scores for all 18 full texts are reported in Supplementary Table S1. ID keys are used throughout this review; H = record identified through citation searching. A4 and A13 are full-length conference publications (see Section 5). Group sizes, application parameters, outcome definitions, and numerical results with measures of variability are given in Supplementary Table S4.
3.2. Substrate Optical State as the Independent Variable (Stage 1)
The included studies converge on the substrate, not the scanner, as the origin of the measurement problem. Three substrate pathologies recur across the pool: specular reflectance of machined metal [12,36,37], subsurface scattering in translucent ceramics [11,42], and feature-poor geometry of edentulous spans and deep post spaces [20,38,43].
Quantitative support for the translucency arm is the strongest single mechanistic observation in the pool. Cho et al. measured the translucency parameter (TP) of ten CAD-CAM ceramics directly and reported a strong correlation between TP and trueness error when no scanning aid was applied (r = 0.854, p < 0.01); with a liquid scanning aid, the TP–trueness relationship disappeared and no significant differences between materials remained [11]. In the companion study across eight restorative materials including cobalt–chromium, scanning-aid application significantly improved accuracy and scan-time efficiency across substrates [42]. On machined metallic models simulating inlay, onlay, and bridge preparations, unaided intraoral scanning was not clinically viable, and all three tested coating agents improved trueness relative to the untreated metal surface [12]. Read mechanistically, Stage 1 defines the optical deficit specular glare or volume scattering that any antiglare coating must neutralise; the coating is therefore an optical interface treatment, not a surface treatment in the mechanical sense.
3.3. Coating Deposition Is the Least Controlled Stage (Stages 2 and 3)
Three studies measured absolute film thickness directly, and one further study estimated coating-related deviation by scan superimposition (Table 2), and their combined finding is that deposition thickness is of the same order of magnitude as the measurement error it is intended to suppress. Lehmann et al. reported mean glass-plate coating thicknesses of 25.3 µm for a white scan spray applied with a conventional pump injector, 18.9 µm for the same spray with a redesigned pump injector (p = 0.017), and 19.2 µm for a blue spray, with confocal laser scanning microscopy showing rough, irregular, non-uniform films for all three [14]. Hategan et al. measured coating thickness as a function of spraying time and reported 27, 39, 42, 76, and 156 µm at one to five seconds, respectively, against a stated scanning precision of approximately 30 µm for the powder-based system evaluated [39]. Burde et al., using three-dimensional superimposition of twenty duplicated casts, found significant differences in root-mean-square deviation between two optical conditioning sprays, with both remaining within a range the authors considered acceptable [45]. Because these estimates quantify deviation between duplicated coated casts rather than absolute film thickness, they are reported separately and are not pooled with the direct-measurement range: the 18.9–156 µm range cited throughout this review derives from the three direct-measurement studies only [14,39,44].
Table 2.
Direct deposition evidence (cascade stages 2–3): reported coating thickness and homogeneity against reported scanner accuracy. IOS = intraoral scanner. Three studies (Lehmann 2011 [14], Hategan 2016 [39], Dehurtevent 2015 [44]) measured absolute film thickness directly; Burde 2016 [45] is a scan-superimposition study whose values estimate coating-related deviation rather than absolute thickness and are listed separately. The 18.9–156 µm range cited in this review derives from the three direct-measurement studies only. The ≈20–30 µm comparator band combines the overall trueness of 20.6 µm reported by Vo et al. [38] with the stated precision of approximately 30 µm for the Apollo DI system reported by Hategan et al. [39]; it is an illustrative, source-specific comparator, not an established tolerance.
Operator behaviour modulates deposition further. Dehurtevent et al. showed that experienced dentists produced significantly more homogeneous coatings than inexperienced operators (92.41 ± 6.65% versus 66.11 ± 12.69% homogeneous area; p < 0.001) and significantly thinner films (43.1 ± 14.09 µm versus 70.19 ± 31.26 µm; p = 0.007) [44]. Hategan et al. independently reproduced the training gradient across dental students, residents, and specialists [39], and Echhpal et al. detected a significant operator effect in one of two application scenarios (p = 0.0212) [35]. Elemental and electron-microscopic characterisation of four imaging powders confirmed that products differ in composition as well as in particle morphology [37]. Stage 2 is therefore the least standardised link in the chain: the same commercial product can reach a surface as a 19 µm or a 70 µm film depending on the injector, the spraying time, and the operator, and the literature provides no accepted tolerance band. Figure 3 bridges these materials-scale observations to the optical mechanism proposed to translate them into measurement error.
Figure 3.
Measured film deposition and the proposed optical mechanism. Top: reported deposited-film thicknesses (18.9–156 µm, directly measured) compared with the nominal scanner-accuracy band (approximately 20–30 µm). Bar colours distinguish the reported experimental conditions: blue represents the A1 conditions (pump B, blue spray, and pump A); orange represents the A4 conditions (spray durations of 1–5 s); and green represents the H1 conditions (experienced and inexperienced operators); purple represents the H2 conditions (sprays A and B), which are scan-superimposition deviation estimates (16.08 and 13.59 µm) rather than direct physical thickness measurements and are therefore shown separately from the directly measured range. The yellow shaded band indicates the nominal scanner-accuracy range of approximately 20–30 µm—the overall trueness of 20.6 µm reported by Vo et al. [38] and the stated precision of approximately 30 µm for the Apollo DI system reported by Hategan et al. [39]—and is provided for reference rather than as an established acceptable film-thickness tolerance; it is an illustrative, source-specific comparator, and scanner accuracy alone does not define a coating-thickness tolerance, which would additionally depend on trueness, precision, reference-method uncertainty, alignment, and application-specific dimensional requirements. Bottom: the proposed optical–interfacial mechanism, illustrated by solid, light-blue boxes with blue outlines, represents five sequential stages from atomisation and wetting to sensor response and mesh deviation. These boxes indicate the proposed mechanistic pathway, not directly measured stages in the included dental scan-spray studies. The solid red-outlined box highlights the dimensional-tolerance problem arising from the reported thickness range. Film-thickness values are measured findings, whereas the proposed mechanism is inferred from surface-science and metrology literature and has not been directly demonstrated for dental scan-spray films.
3.4. Coating Agents Are Not Mechanistically Interchangeable (Stage 4)
The three studies of the Seoul National University group provide the clearest class comparison. Against printed reference models, the liquid-type agent (ScanCure) produced fewer errors than the powder-type agents (IP Scan Spray, VITA Powder Scan Spray) in inlay, onlay, and bridge geometries, with the inlay difference reaching p < 0.001 [40]. In full-arch scanning, by contrast, Oh et al. (2021) [41] detected no statistically significant differences between treatments in three-dimensional trueness for either intraoral scanner. However, with the i500 scanner, VITA showed better precision than ScanCure and IP, while scanning times also differed among the aids. These findings do not support a consistent ranking of the evaluated treatments across outcomes.
On metallic models, ScanCure and IP outperformed VITA in inlay and onlay geometries and ScanCure was best in the bridge geometry [12]. A sustainable-substitution study detected no statistically significant difference between waste zirconia dust and a commercial optical scanning spray (equivalence not formally tested) in extraoral scanning of implant abutment models [35], and an early CEREC study detected no statistically significant difference in crown marginal fit or internal adaptation (equivalence not formally tested) between titanium-dioxide powder applied by mechanical sprayer and an aerosol contrast spray [15]. Rajab and Jasim reported no statistically significant difference between a liquid paint and a powder spray (equivalence not formally tested) for the internal fit of zirconia crowns on metal implant abutments [36].
Read against Stage 4, these results are consistent with a single optical requirement—conversion of the surface to a diffuse, Lambertian-like scatterer of sufficient and uniform thickness which different chemistries meet to different degrees. On mechanistic grounds, liquid agents would be expected to self-level into thinner, more uniform films, whereas powders would be expected to deposit as particulate layers whose scattering efficiency depends on particle size and packing (Mie-type behaviour; see Section 4). The agents are therefore not mechanistically interchangeable even where their headline accuracy outcomes appear similar: interventions acting at different points of a measurement chain cannot be treated as equivalent. Figure 4 maps the intervention strategies documented across the evidence base onto the cascade stages at which each acts.
Figure 4.
Antiglare strategies mapped to their point of action in the measurement cascade. Filled circles mark the primary cascade stage at which each strategy is proposed to act, ringed circles mark secondary or indirect proposed engagement, and grey circles mark stages with no documented engagement in the reviewed evidence. Assignments are inferred from disclosed compositions and from measured deposition or scan outcomes; engagement at the light-interaction stage is hypothesised, not documented, because no included study measured molecular or optical readouts of a deposited film directly.
3.5. Coatings on Printed Models, Metals, and Ceramics
Six studies used 3D-printed models as the scanned substrate or as the support for restorative specimens [11,38,40,41,42,43]. On printed inlay, onlay, and bridge models, the liquid scanning aid produced fewer errors than the powder comparators [40]; the same research programme reported scanner-dependent aid effects on a printed full-arch model [41]. Printed arches supporting crowns of eight restorative materials showed improved accuracy and scan-time efficiency with either powder- or liquid-based aids [42], while the ceramic-translucency study used printed models to support ten CAD/CAM ceramic crowns and found that the liquid aid removed the translucency–trueness association present without conditioning [11]. On a printed Kennedy class I model, titanium-dioxide powder and composite landmarks differed by only 2.7 µm in overall trueness, with regional errors concentrated in feature-poor areas [38]. On printed post-space models, the liquid aid improved trueness within the investigated recognition limits [43]. Collectively, these are measured scan-mesh or fit outcomes on printed models, not dimensional verification of a final additively manufactured patient-specific device. Whether these printed-model results transfer to other printing technologies, resins, or post-processing states is untested.
The metal and ceramic evidence addresses complementary optical problems but should not be relabelled as additive-manufacturing validation. Coatings improved acquisition on specially designed metallic models [12], whereas no statistically significant improvement was detected for powder on modern intraoral scans (equivalence not formally tested) of complete-arch implant-supported frameworks [19]; waste zirconia dust and commercial spray were comparable on implant abutment models [35], and no statistically significant difference was detected between liquid paint and powder spray for the internal fit (equivalence not formally tested) of zirconia crowns on metal abutments [36]. Ceramic evidence was generated principally on CAD/CAM crowns and restorative-material comparisons [11,36,42]. No eligible study isolated an additively manufactured metal or ceramic substrate, and no study measured a final printed component after coating removal. The direct evidence therefore supports conclusions about optical acquisition on printed models and metal or ceramic substrates; final-device accuracy for printed polymers, metals, and ceramics remains an evidence gap. The transferability of these findings across substrate classes is limited: coating deposition and optical response depend on substrate roughness, surface energy, and reflectance, so effects measured on printed resins, milled or cast metals, and CAD/CAM ceramics cannot be assumed to transfer between substrate classes or to final printed devices without direct verification.
3.6. Scanner Technology Moderates the Coating Effect (Stage 5)
The coating effect is contingent on the imaging chain. Borga Donmez et al. digitised complete-arch implant frameworks with an industrial blue-light scanner and three intraoral scanners, with and without anti-reflective scan powder: no statistically significant difference was detected in whole-surface or marginal RMS values after powder application for any of the tested intraoral scanners (p ≥ 0.054; equivalence not formally tested), while deviations of all intraoral scans exceeded those of the industrial reference, with a maximum raw mean difference of 37.33 µm [19]. Jamjoom et al. crossed two scanners with four aid conditions and found the aid effect reversed between systems: scanning aids improved the trueness of TRIOS 4 scans of edentulous arches, whereas composite markers and liquid aid produced the best trueness for the Emerald S [20]. Zou et al. showed that recognition limits for post-space scanning an opening diameter of 2.5 mm and depth ≤ 10 mm with adjacent teeth present are properties of the scanner–geometry interaction, with the liquid aid improving trueness within those limits [43]. The same coating can thus improve, leave unchanged, or degrade accuracy depending on whether the scanner’s illumination and triangulation geometry is the limiting factor—the Stage-5 expression of a general property of cascaded measurement chains: interventions engaging different stages cannot be compared on effect size alone.
3.7. Where the Error Lands: Regional Deviation and the Marker Alternative (Stage 6)
Errors concentrated where surface features are sparse. Vo et al. reported high overall trueness for TiO2-powdered and composite-landmark scans of a Kennedy class I model (mean 20.6 µm; composite–TiO2 difference 2.7 µm), with significant regional deviations localised to the palate and maxillary tuberosity, the feature-poor zones of the arch [38]. Kim et al. had earlier shown that an applied composite landmark on a long edentulous span improved the accuracy of intraoral digital impressions [46], and marker arms outperformed or matched sprays in the edentulous-arch study of Jamjoom et al. [20]. Markers act at Stage 6, primarily targeting registration rather than the surface optics of Stages 2–4: they supply artificial correspondence features for reconstruction, and their success on the substrates where sprays struggle most is direct evidence that part of the “coating effect” in edentulous scanning is geometric rather than optical.
3.8. Methodological Quality of the Included Studies
All 18 full texts were appraised with the QUIN tool; the full text of A2 [15], previously available only as an abstract, was obtained during revision and was scored with the same procedure (14/24, 58.3%, medium risk of bias). Scores ranged from 54.2% to 79.2% (mean 62.5%). Two studies fell in the low risk-of-bias band [35,44]; the remainder were medium; none was high. Aims, comparison groups, methodology, outcome measurement, statistical analysis, and presentation were adequately specified in nearly all studies. Randomisation was absent throughout, and no study reported complete outcome-assessor blinding; only two studies reported an a priori sample-size calculation. Operator details were adequately specified in seven studies, partially specified in two, and absent in nine; A6 and A7 were scored as adequately specified because the publications described proficient or skilled prosthodontists. Per-criterion scores and the textual basis for each judgement are reported in Supplementary Table S1 and visualised in Figure 5.
Figure 5.
Per-criterion QUIN appraisal of all 18 included studies, including total scores, percentages, and risk-of-bias categories. A6 and A7 operator details were scored as adequately specified based on the information reported in the publications. The full text of A2 was obtained during revision; it is scored (14/24, 58.3%, medium risk of bias) and included in the appraisal matrix. Cell colours denote the per-criterion score (green = 2, adequately reported; yellow = 1, partially reported; red = 0, not reported); risk-band colours denote the risk-of-bias category (green = low, >70%; amber = medium, 50–70%; red = high, <50%).
Interpretation stratified by QUIN score. Because scores fell within a narrow band (54.2–79.2%) and no study was at high risk of bias, the appraisal was used as a sensitivity lens rather than as an exclusion rule. The two low-risk-of-bias studies capture both central themes of this review: Dehurtevent et al. [44] directly measured operator-dependent film thickness (43.1 versus 70.2 µm for experienced versus inexperienced operators), and Echhpal et al. [35] found no statistically significant difference between waste zirconia dust and a commercial spray while detecting a significant operator effect in one application scenario. Restricting interpretation to these two studies therefore does not change the qualitative conclusions regarding operator dependence and the comparability of conventional and alternative agents, and no conclusion in this review rests solely on lower-scoring evidence. The QUIN band thresholds (>70% low, 50–70% medium, <50% high risk of bias) are convention-based and have not been validated for in vitro dental-imaging studies; per-study scores should accordingly be read as indicative rather than definitive.
3.9. The Wet-Surface Gap
Every included study scanned dry, clean, controlled models. No eligible study conditioned the substrate with saliva, blood, or water films before coating, although the wider evidence base shows that surface liquid degrades intraoral scan accuracy [47,48,49] and that a water film alone introduces a triangulation-angle error on powder-free systems [10]. The clinical sequence—moist surface, coating application onto or through the film, scanning is therefore untested at every cascade stage: wetting changes substrate reflectance (Stage 1), interferes with particle deposition and film formation (Stages 2–3), and adds a refracting layer to the optical path (Stage 4). This is the optical analogue of the conditioning-film gap described in other material–biofilm studies, and it defines the most urgent experimental agenda for this field (Section 4.5). The gap is summarised graphically in Figure 6.
Figure 6.
The wet-surface gap in additive-manufacturing workflows. Left: dry, clean, controlled substrates used in the included studies. Right: the saliva-covered clinical condition, in which deposition onto or through a liquid film may create refracting interfaces and uncoated windows. Bottom: consequences for evidence transfer and digital-model geometry. No included study tested this clinical condition or verified propagation into a final additively manufactured device. Created with Matplotlib (version 3.10.3; https://matplotlib.org) and subsequently modified using Microsoft PowerPoint with assistance from Kimi AI.
4. Discussion
Interpretation of this evidence base through the six-stage measurement cascade summarised in Figure 1 begins with the coating itself: what is deposited, how it interacts with the substrate, and how those interfacial events become optical signal (Section 4.1). The discussion then separates measured scan outcomes from proposed downstream mechanisms and connects formulation, deposition, optical response, and dimensional verification within additive-manufacturing workflows (Section 4.2, Section 4.3, Section 4.4, Section 4.5 and Section 4.6).
4.1. Molecular and Interfacial Mechanisms: Documented Compositions and Hypothesised Interactions
A molecular reading of the cascade must begin with what is actually deposited, because “scanning aid” is a functional label rather than a chemical one. Table 3 assembles the documented compositions of the coating systems encountered in this literature. Within the pool, Oh et al. identified the agents reaching their metallic models by ingredient disclosure: IP Scan Spray is a TiO2 suspension in ethanol expelled by a propane/butane/isobutane propellant; VITA Powder Scan Spray contains no TiO2 at all but a blue pigment in ethanol with isobutane; and ScanCure is a TiO2-containing ethanol liquid applied without propellant [12]. Alghazzawi et al. confirmed by electron microscopy and elemental analysis that four imaging powders differed in both composition and particle morphology [37]. Beyond the pool, the documentation is toxicological, regulatory, and manufacturer-issued rather than experimental. A standardised examination of five commercial scanning sprays found materially different declared compositions—carriers variously based on heptafluoropropane, n-pentane, naphtha, and ethanol, and solid phases variously comprising TiO2, ZrO2, talcum, and zinc distearate with particle number concentrations peaking near 200 nm [50]. The FDA 510(k) summary for the IOS FastScan Spray describes both it and its predicate, the legacy CEREC Opti Spray, as a pigment suspension “comprised principally of titanium oxide and ethanol” expelled by a fluorinated hydrocarbon propellant [51]. The current CEREC Optispray operating instructions (Ref. 6687698, document version dated 9 October 2023) describe a materially different product under the same market lineage: a pigment suspension based on zinc sulfide, pentane, and ethanol, with trans-1,3,3,3-tetrafluoroprop-1-ene as propellant and peppermint oil as flavouring [52]. In industrial 3D metrology, self-sublimating sprays form a further, chemically unrelated class that deposits films in the tens of micrometres and then disappears by sublimation over 47–444 min depending on the product [53]. Two conclusions follow. Products sold under one category label are not chemically identical: the CEREC spray line itself changed its pigment from titanium oxide [51] to zinc sulfide [52] between regulatory generations. Reported per product, this class is chemically heterogeneous rather than uniformly cyclododecane-based: of the eight products compared in that study, four (Reflecon Tarnish 50 and Attblime AB6, AB2, and AB Zero) are cyclododecane-based, whereas the AESUB products (Blue and Orange) and Reflecon Tarnish 11-HC and 12-HC are based on other materials, and the exact composition of each product is not disclosed by its manufacturer [53]. Mechanistic claims must therefore attach to documented formulations, not to categories.
Table 3.
Documented compositions of antiglare and scanning-aid coating systems, distinguishing peer-reviewed dental evidence (Arm A) from regulatory, manufacturer, and adjacent-literature documentation (Arm B). LPG = liquefied petroleum gas.
Two further coating classes appear in scanning practice without any peer-reviewed dental evaluation, and their documentation must be labelled as such. Aerosol dry shampoos, adopted in practice as low-cost antiglare powders, are documented in the cosmetic patent literature as 70–90% liquefied petroleum propellant (butane/isobutane/propane), 4–8% rice, corn, or tapioca starch as the absorbent solid, and 4–8% denatured alcohol as carrier, with fragrance and cationic antistatic agents such as cetrimonium chloride [54]; alternative documented formulations replace most of the propellant with 65–96% starch and 4–35% baking soda [55]. Cornstarch–ethanol suspensions are documented only at the level of their constituents: native cornstarch is a semi-crystalline, hydroxyl-rich amylose/amylopectin polysaccharide granule that is insoluble in cold ethanol [56], so ethanol necessarily acts as a volatile, non-solvent dispersing carrier. No peer-reviewed study has measured a cornstarch–ethanol or dry-shampoo film on a dental substrate, and the concentration-dependent effects claimed for cornstarch suspensions in practice remain unevidenced. These classes therefore enter the analysis as formulation classes documented outside dentistry, and every mechanistic statement about them below is correspondingly labelled.
The candidate interactions at the coating–substrate interface can be inferred from the functional groups disclosed in the available product documents. The pigment solids (TiO2, ZnS, ZrO2, and talc) differ in their surface chemistry: TiO2, ZrO2, and talc present hydroxylated, polar oxide or silicate surfaces, whereas ZnS is a sulfide rather than an oxide and may carry adsorbed water and partial surface hydroxylation under ambient conditions. Starch granules, in turn, present dense hydroxyl networks [56]. On these surfaces, plausible intermolecular mechanisms include London dispersion (van der Waals) attraction, which acts universally between particles and substrates; polar and hydrogen-bonding interactions between particle-surface hydroxyl groups and substrate oxide or hydroxyl groups; electrostatic attraction or repulsion arising from particle tribocharging during atomisation; and capillary adhesion through liquid bridges while the carrier evaporates. Formulation additives may modify this balance. For example, zinc distearate, declared in one product [50], is a hydrophobic surface modifier that may weaken particle–particle cohesion and thereby favour more dispersed film morphologies.
Critically, none of these interactions has been experimentally demonstrated for a scanning-aid film. The available evidence demonstrates composition through elemental analysis and document disclosure [12,37,50,51,52], as well as macroscopic deposition behaviour, including film thickness and homogeneity [14,39,44,45]. However, no included study reported surface-energy, adhesion-force, zeta-potential, or spectroscopic measurements of a deposited film. The documented removability of the films by air/water spray after exposure [52] provides macroscopic evidence of weak physical retention; moreover, no source in this literature reports or claims covalent bonding or a chemical reaction between the coating and the substrate. The interaction mechanisms discussed above should therefore be regarded as hypotheses derived from colloid and surface science and as a basis for the measurements proposed in Section 4.6, rather than as experimentally demonstrated mechanisms.
The substrate side of the interface is better characterised than the coating side. Cast cobalt–chromium dental alloys present passivated surfaces rich in chromium and cobalt oxides, whose state and morphology depend on casting and finishing [57]. Mechanical surface treatments, such as sandblasting, markedly increase surface roughness and alter wettability compared with polished surfaces [58]. The ceramic and resin substrates listed in Table 1 likewise present oxide- or hydroxyl-bearing surfaces, although their surface conditions are rarely reported.
Against this background, three potential retention regimes should be distinguished. Adsorption refers to the reversible intermolecular attachment of particles to the substrate surface. Mechanical retention refers to the physical entrapment of particles within surface microrelief; it may be an important mechanism for micrometre-scale particulate films on roughened metal surfaces and is consistent with the industrial finding that TiO2-based residues are more difficult to remove from rough surfaces [53]. Chemical bonding, the third potential regime, has no supporting evidence in the available literature.
Wettability can influence particle spreading. An ethanol-based carrier may spread on a clean, high-energy oxide surface but bead on a contaminated surface, potentially producing agglomerated and non-uniform coatings. This interpretation is consistent with the manufacturer’s contraindications against application “on uncleaned surfaces” and “on wet surfaces” [52], as well as with the wet-surface evidence gap identified in Section 3.9.
Finally, the volatile carriers evaporate within seconds of deposition. Redistribution of particles during drying–including capillary flow, edge-ward deposition, and packing consolidation–is expected from the physics of drying colloidal films and may influence the final film morphology. However, these drying processes have not been directly measured for any of the formulations in Table 3. The measured outcome is the presence of rough, irregular films, 19–70 µm thick, whose uniformity is operator-dependent [14,39,44]. These observations represent the macroscopic residue of interfacial processes that remain largely uncharacterised.
The documented compositions allow the optical stage of the proposed cascade to be discussed quantitatively rather than generically. Light scattering by a particulate film depends on particle size relative to the wavelength of light and on the refractive-index contrast between the particles and the surrounding medium. Rutile TiO2 exhibits strong scattering when particle size is in the submicrometre range, with an approximate optimum near 250 nm under the conditions reported in the cited literature [21,22,23]. The refractive indices of the documented pigments differ substantially: rutile TiO2 has a refractive index of approximately 2.71–3.02 at 500 nm (anatase: approximately 2.57) [59], zinc sulfide approximately 2.36 [60], and organic solids such as starch approximately 1.5. Because scattering generally increases with refractive-index contrast [23], zinc-sulfide films may require a greater deposited volume than rutile TiO2 films to achieve comparable diffuse reflectance. Starch-based films may require an even greater volume, assuming comparable particle size and packing. This expectation is consistent with the industrial observation that a calcium-carbonate (CaCO3; n ≈ 1.6) antiglare layer required approximately 44 µm to achieve an optical result that a TiO2 layer achieved at roughly one-tenth of that thickness [53].
However, extending this calcium-carbonate benchmark to starch is an extrapolation rather than a direct measurement. Starch has a lower refractive index (approximately 1.5) than calcium carbonate, and no starch-based film has been measured on a dental substrate. Its required thickness therefore remains unknown and requires experimental investigation. Composition may consequently influence optical performance: the documented chemistry (Table 3) affects the potential scattering per unit thickness, while the deposited film thickness determines whether the coating falls within the acceptable range discussed in Section 4.2. The deposited film is also expected to modify the bidirectional reflectance distribution toward the diffuse-reflection conditions required for optical scanning [24,25].
The limits of the available evidence must nevertheless be emphasised. Although the underlying optical principles are established in pigment science, no included study measured the reflectance, bidirectional reflectance distribution function (BRDF), or scattering coefficient of a deposited scanning-aid film. Their application to dental coatings therefore remains a theoretically informed interpretation, constrained by the documented compositions but not yet confirmed by direct optical measurements.
Read as interfacial interventions rather than as a product category, the four coating states differ at every stage of the chain. TiO2 pigment sprays combine the highest refractive-index contrast with the thinnest adequate films, the strongest aerosol-exposure concerns [50], and residues that persist preferentially in surface roughness [53]. Cornstarch–ethanol suspensions and dry-shampoo aerosols share a low-index, hydroxyl-rich, hygroscopic solid phase: they are expected to require thicker deposits for equivalent scattering, to adhere physically rather than chemically, and to be the most moisture-sensitive of the classes on a saliva-wet substrate. These are expectations, not measurements—neither class has been evaluated in the peer-reviewed dental literature, and the documented within-class variability of dry-shampoo formulations [54,55] precludes any blanket statement about “dry shampoo” as a scanning aid. The uncoated reflective CoCr surface passivated chromium/cobalt oxide with high specular reflectance [57] is the reference state that defines the problem: it is the surface on which unaided optical acquisition fails or degrades [10,12] and against which every coating effect in Table 1 is measured. The mechanistic reading thereby converts “scanning aid” from a purchasing category into a set of formulation-specific interfacial interventions whose demonstrated content today is compositional and depositional, and whose molecular and optical mechanisms constitute the hypothesis set that future studies must test directly.
4.2. Coating Deposition Constitutes an Uncontrolled Optical Variable
The prevailing account of scanning aids is essentially binary: a surface either is or is not “coated.” The deposition studies in this review show that the coated state is a continuum whose extremes bracket the measurement itself. Reported film thicknesses span 18.9 to 25.3 µm (a difference of 6.4 µm) between pump-injector designs for a single product [14], 27 to 156 µm across one to five seconds of spraying [39], and 43.1 versus 70.2 µm between experienced and inexperienced operators [44], against reported scanner accuracy of approximately 20–30 µm (stated precision [39]; reported trueness [38]). A coating applied for five seconds—the longest duration tested—therefore adds a layer up to five times thicker than the reported accuracy of the instrument it serves, demonstrating that the optical-conditioning intervention can exceed the signal.
Thin-film and pigment optics supply the mechanistic reading (Section 4.1). Antiglare function requires conversion of the substrate to a diffuse scatterer whose reflected radiance is angle-independent, formally, a shift of the bidirectional reflectance distribution function toward the Lambertian limit [24,25]. For particulate TiO2 coatings, scattering efficiency is maximal near a particle diameter of ~250 nm and degrades with aggregation and with packing anomalies [21,22,23]. Both failure modes are thickness-sensitive: too little powder leaves specular micro-domains exposed, whereas excessive powder may produce a topographically rough, weakly bound overlayer whose microrelief is itself captured during scanning. The optimum is therefore a thickness range rather than a maximum value. However, the available literature has not yet established a validated optimal thickness range. Deposition should consequently be conceived as dosing within a tolerance window, but the boundaries of this window cannot be determined from scanner precision alone. Scanner repeatability is only one contributor to final-device error, alongside trueness of the acquisition, reference-geometry and reference-measurement uncertainty, scan-alignment and superimposition error, and the application-specific dimensional requirements of the device (for example, marginal and internal fit thresholds for crowns versus relief and intaglio adaptation for printed dentures). A defensible coating-thickness tolerance must therefore be defined per application and validated against final-device dimensions; it cannot be inferred from instrument specifications or product instructions.
4.3. Reported Accuracies Are Not Commensurable
Ranking coating agents by their reported accuracy presupposes a comparability that the pooled methods do not support. The eighteen studies express error as whole-surface RMS [12,19,20,40,41], mean deviation after best-fit alignment [38], regionally cropped deviation of post-space walls [43], marginal and internal fit of crowns [15,36,37], and coating homogeneity itself [39,44,45]. Reference geometry was supplied by laboratory scanners, an industrial blue-light scanner, design data, or measuring microscopes, and alignment used different software and different region-of-interest definitions. These metrics weight different stages of the cascade: fit outcomes integrate design and milling error downstream of scanning, RMS integrates registration quality across the whole surface, and cropped-region deviation isolates reconstruction locally. The finding that agents “differ” or “do not differ” is therefore partly a reflection of which stage the chosen metric captures. No cross-study effect-size ordering is consequently defensible. This limitation also arises whenever non-commensurable in vitro outcome measures are compared across studies.
A second source of non-commensurability is the technology used for image acquisition. The studies included different optical principles, including laser triangulation, confocal microscopy, active wavefront sampling, and structured-light fringe projection [27,28,29,30]. A coating that modifies the bidirectional reflectance distribution function (BRDF) may therefore affect different scanner technologies to different extents. In particular, a reduction in specular reflection may benefit a triangulation-based system differently from a confocal system. The reversed rankings of scanning aids between TRIOS 4 and Emerald S [20], together with the absence of a powder effect on three modern intraoral scanners [19], support the interpretation that the effect of a coating depends on the scanner technology rather than representing a uniform main effect.
4.4. Formulation, Deposition, Optical Response, and Dimensional Verification
The additive-manufacturing perspective requires four evidence layers to be connected without conflating them. Formulation is documented by ingredient disclosure, regulatory or manufacturer documents, and elemental or microscopic analysis (Table 3). Deposition is measured directly as film thickness, homogeneity, and operator-dependent variability [14,39,44,45]. Optical response is the next layer, but no included study measured reflectance, BRDF, scattering coefficient, or subsurface transport of a deposited dental scanning-aid film; Mie scattering and BRDF flattening therefore remain proposed mechanisms. Dimensional verification in the included studies ends at scan-mesh trueness or precision, regional deviation, or a downstream fit outcome [12,19,20,38,40,41,43]. None completes the chain by additively manufacturing a patient-specific component from the coated scan and verifying the final additively manufactured component dimensionally.
A definitive verification protocol should therefore follow one geometry through the complete workflow: additively manufacture standardised polymer, metal, and ceramic substrates or device replicas with reference features; measure their uncoated geometry by coordinate metrology or computed tomography; characterise formulation and map deposited-film thickness; measure optical reflectance or BRDF; acquire scans under controlled conditions; remove the coating; manufacture the intended component; and verify its final dimensions against the same reference. A known uniform offset could then be distinguished from non-uniform local deformation, and optical measurements could be tested as mediators of mesh and final-component error. This protocol is a proposed research design, not a result of the present review.
Table 4 maps each principal claim of this review to its evidence tier, the evidence that supports it, and what remains untested; the distinction between measured, inferred, and absent evidence bounds every conclusion drawn above.
Table 4.
Evidence-to-claim map of the review: principal claims, their evidence tiers, supporting evidence, and the components that remain untested. BRDF = bidirectional reflectance distribution function.
4.5. Limited Evidence Under Moist-Surface Conditions
The clinical scanning surface is wet, variably illuminated, and topographically irregular; the tested surface was dry, clean, and controlled in every included study. The wider evidence base indicates that this is not a cosmetic difference: a liquid film on the tooth surface measurably degrades intraoral scan accuracy [47], saliva contamination alters finish-line capture [48], restorative-material accuracy is wetness-dependent [49], and a water film alone introduces a triangulation-angle error on powder-free systems by adding a refracting interface [10]. Physically, a saliva film changes both the substrate reflectance that the coating must flatten (Stage 1) and the interfacial adhesion and drying behaviour of the film (Stages 2–3); a powder sprayed onto a wet surface is a different coating from the same powder sprayed dry. The translucency parameter reported in [11] correlated with trueness loss (r = 0.854) in scans acquired without a scanning aid and reflects a subsurface-scattering phenomenon [26], and subsurface transport in enamel is plausibly moisture-dependent (enamel opacity rises with dehydration, the basis of the drying assessment in caries diagnosis), although this has not been tested in scanning-aid contexts. None of the included studies tested a coating on a saliva-conditioned substrate, so the cascade as charted describes a laboratory surface. Statements about clinical performance extrapolate beyond the evidence.
4.6. Implications for the Design of Future Studies
The cascade suggests a minimum reporting and design set for this literature: (i) report the deposited film, not just the product mean and spatial variance of coating thickness by confocal or superimposition methods [14,45]; (ii) declare operator training and standardise deposition parameters (distance, time, passes), given the twofold experience gradient in thickness [39,44]; (iii) state the scanner’s imaging principle and software version, since the coating effect is moderated by both [19,20]; (iv) report accuracy per ISO 12836-style trueness/precision definitions [61,62] with the reference method and alignment protocol specified; (v) add a saliva-conditioned arm, the absent clinical surface (Section 3.9); (vi) calculate sample size a priori (only two of the eighteen studies did so [35,36]) and randomise scan order with blinded outcome assessment (not reported in any included study); and (vii) characterise particle size distribution and composition of the agent, since scattering efficiency is size-dependent near ~250 nm for TiO2 [23,37]. A standardised deposition device delivering a metered dose would convert the weakest cascade stage into a controlled variable.
A concrete, testable design follows directly from this set: a factorial in vitro study crossing (a) coating agent (a documented TiO2 aerosol, a ZnS aerosol, a sublimation spray, and a starch-class alternative) with (b) three controlled dose levels defined by measured film thickness (for example, target films of approximately 10, 30, and 60 µm, verified by confocal microscopy or superimposition rather than inferred from spray time), on (c) substrates spanning the additive-manufacturing space (3D-printed resin, milled polymer, and printed-metal replicas of one standardised preparation geometry, together with a printed denture base), under (d) two surface conditions (dry versus a standardised artificial-saliva film), with acquisition on at least two imaging principles (for example, confocal and structured-light). Every arm should report scan-mesh trueness and precision against a coordinate-metrology reference and should then carry the identical geometry through printing and post-processing, so that mesh-level error can be compared directly with final-printed-part error and the propagation or absorption of coating-induced deviations by the additive workflow can be quantified. Application order should be randomised, applicators trained to a metered protocol, and outcome assessors blinded to agent and dose, with primary endpoints, equivalence margins (for example, ±20 µm), and an a priori sample-size calculation registered before data collection rather than reliance on non-significant superiority tests.
5. Limitations
This review has a deliberate methodological asymmetry: the appraised evidence base was assembled systematically, whereas the optical framework used to interpret it was assembled by targeted searching and selected for mechanistic relevance. Relevant optical work may therefore have been omitted, and the framework should be read as an interpretive structure rather than an exhaustive synthesis.
The evidence base is small and heterogeneous: eighteen studies spanning 2011–2026, most with ten or fewer replicates per condition, evaluating different agents, substrates, scanners, reference methods, and outcome metrics that are not commensurable (Section 4.3); no quantitative pooling was attempted. The full text of Cook and Fasbinder (2012) [15] was obtained during revision, and the study is now appraised in full with the same procedure (14/24, 58.3%, medium risk of bias; Supplementary Table S1); its numerical results are integrated in Table 1 and Section 3.4. Two full-length research reports published in conference-related outlets were included: one paper in SPIE proceedings [39] and one paper in a journal’s conference supplement [36]. Both reported complete quantitative datasets relevant to the review (a spray-time–thickness series [39] and a scanning-aid comparison on metal implant abutments [36]) and were assessed against the same substantive eligibility criteria as the other included studies. Conference abstracts without a full research report were excluded. Restriction to English-language publications excluded at least one otherwise eligible study, and citation chasing beyond the three databases was limited to reference-list screening.
Risk-of-bias appraisal placed all appraised studies in the medium band except two, and the universal absence of reported randomisation and assessor blinding means measurement bias cannot be excluded for any study, although software-generated deviation metrics mitigate assessor subjectivity relative to biological assays. The optical mechanisms discussed (Mie scattering, BRDF flattening, subsurface transport) were established in pigment science, computer graphics, and optical metrology, not on dental substrates; their operation on scan-spray films is inferred, not demonstrated, and no included study measured an optical property of a deposited coating directly. Finally, all included studies were in vitro, and none evaluated coating removability, residue, or patient exposure beyond the aerosol-characterisation literature cited in the framework [63]. The QUIN tool was selected because it was developed and validated for in vitro dental research, but its percentage band thresholds (>70%, 50–70%, <50%) are convention-based rather than empirically validated cut-offs, and the narrow score range in this pool (54.2–79.2%) limits the appraisal’s discriminative power; the band assignments should therefore be read as indicative, not definitive.
6. Conclusions
Optical-conditioning coatings should be evaluated as controlled geometric and optical interventions within additive-manufacturing workflows, not as interchangeable scanning accessories. Measured evidence shows that deposited films span 18.9–156 µm, vary with formulation, application hardware, spray duration, and operator expertise, and can improve, leave unchanged, or degrade scan outcomes depending on substrate and scanner. Six studies provide direct evidence on 3D-printed models, while the metal and ceramic evidence arises mainly from milled or CAD/CAM substrates; no eligible study isolated additively manufactured metal or ceramic specimens. The literature therefore supports conclusions about composition, deposition, scan-mesh accuracy, and selected fit outcomes, but not about final printed-device accuracy. No study connected coating formulation and deposition to a measured optical film response and then to dimensional verification of a manufactured patient-specific component. Likewise, propagation of coating-induced mesh error into a final device and the optical behaviour of films on saliva-conditioned substrates remain proposed mechanisms rather than demonstrated findings. Standardised deposition, direct optical characterisation, saliva-conditioned experiments, and end-to-end post-print dimensional verification are required before coating protocols can be prescribed for additive manufacturing on mechanistic grounds. Until such verification exists, the mechanistic interpretations offered here are hypotheses to be tested, and the clinical use of optical-conditioning coatings on additively manufactured devices should be regarded as provisional, guided by measured deposition on the specific substrate–scanner combination rather than by category-level assumptions.
Supplementary Materials
The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/ijms272310779/s1.
Author Contributions
M.A. contributed to conceptualization, methodology, investigation, data curation, formal analysis, and writing—original draft preparation. A.M.H. contributed to methodology, investigation, data curation, and formal analysis. N.H. contributed to conceptualization, writing—review and editing, supervision, and project administration. M.A.-R. contributed to writing—review and editing, and supervision. J.Y.A. contributed to writing—review and editing, supervision, and project administration. All authors have read and agreed to the published version of the manuscript.
Funding
This research received no external funding.
Institutional Review Board Statement
Not applicable.
Informed Consent Statement
Not applicable.
Data Availability Statement
No new data were created or analysed in this study. Data sharing is not applicable to this article.
Acknowledgments
During the preparation of this work, the authors used an AI-based assistant Kimi K2.8 (Moonshot AI) for language editing, reference-list management, and figure and table preparation. The authors reviewed and edited all content and take full responsibility for the integrity and accuracy of this publication. No AI tool was used to generate, analyse, or interpret data. All appraisal judgements were confirmed by the authors.
Conflicts of Interest
The authors declare no conflicts of interest.
Abbreviations
BRDF, bidirectional reflectance distribution function; CAD/CAM, computer-aided design/computer-aided manufacturing; HFO, hydrofluoroolefin; IOS, intraoral scanner; LPG, liquefied petroleum gas; PRISMA, Preferred Reporting Items for Systematic Reviews and Meta-Analyses; PRISMA-ScR, PRISMA extension for Scoping Reviews; QUIN, Quality Assessment Tool for In Vitro Studies; RMS, root mean square; RoB, risk of bias; SDS, safety data sheet; SEM, scanning electron microscopy; TP, translucency parameter.
References
- Ender, A.; Mehl, A. Accuracy of complete-arch dental impressions: A new method of measuring trueness and precision. J. Prosthet. Dent. 2013, 109, 121–128. [Google Scholar] [CrossRef] [Scilit]
- Nedelcu, R.G.; Persson, A.S. Scanning accuracy and precision in 4 intraoral scanners: An in vitro comparison based on 3-dimensional analysis. J. Prosthet. Dent. 2014, 112, 1461–1471. [Google Scholar] [CrossRef] [Scilit]
- Patzelt, S.B.; Emmanouilidi, A.; Stampf, S.; Strub, J.R.; Att, W. Accuracy of full-arch scans using intraoral scanners. Clin. Oral Investig. 2014, 18, 1687–1694. [Google Scholar] [CrossRef] [Scilit]
- Güth, J.F.; Edelhoff, D.; Schweiger, J.; Keul, C. A new method for the evaluation of the accuracy of full-arch digital impressions in vitro. Clin. Oral Investig. 2016, 20, 1487–1494. [Google Scholar] [CrossRef] [Scilit]
- Imburgia, M.; Logozzo, S.; Hauschild, U.; Veronesi, G.; Mangano, C.; Mangano, F.G. Accuracy of four intraoral scanners in oral implantology: A comparative in vitro study. BMC Oral Health 2017, 17, 92. [Google Scholar] [CrossRef] [Scilit]
- Mangano, F.G.; Veronesi, G.; Hauschild, U.; Mijiritsky, E.; Mangano, C. Trueness and precision of four intraoral scanners in oral implantology: A comparative in vitro study. PLoS ONE 2016, 11, e0163107. [Google Scholar] [CrossRef] [Scilit]
- Mangano, F.G.; Hauschild, U.; Veronesi, G.; Imburgia, M.; Mangano, C.; Admakin, O. Trueness and precision of 5 intraoral scanners in the impressions of single and multiple implants: A comparative in vitro study. BMC Oral Health 2019, 19, 101. [Google Scholar] [CrossRef] [Scilit]
- Abduo, J.; Elseyoufi, M. Accuracy of intraoral scanners: A systematic review of influencing factors. Eur. J. Prosthodont. Restor. Dent. 2018, 26, 101–121. [Google Scholar] [CrossRef] [Scilit]
- Alkadi, L. A comprehensive review of factors that influence the accuracy of intraoral scanners. Diagnostics 2023, 13, 3291. [Google Scholar] [CrossRef] [Scilit]
- Kurz, M.; Attin, T.; Mehl, A. Influence of material surface on the scanning error of a powder-free 3D measuring system. Clin. Oral Investig. 2015, 19, 2035–2043. [Google Scholar] [CrossRef] [Scilit]
- Cho, J.H.; Han, J.S.; Yoon, H.I. Effect of translucency of CAD-CAM ceramic restorative materials and scanning aid conditions on the accuracy of intraoral scans. J. Dent. Sci. 2023, 18, 1212–1218. [Google Scholar] [CrossRef] [Scilit]
- Oh, H.S.; Lim, Y.J.; Kim, B.; Kim, M.J.; Kwon, H.B.; Baek, Y.W. Effect of scanning-aid agents on the scanning accuracy in specially designed metallic models: A laboratory study. PLoS ONE 2022, 17, e0267742. [Google Scholar] [CrossRef] [Scilit]
- Mörmann, W.H. The evolution of the CEREC system. J. Am. Dent. Assoc. 2006, 137, 7S–13S. [Google Scholar] [CrossRef] [Scilit]
- Lehmann, K.M.; Azar, M.S.; Kämmerer, P.W.; Wentaschek, S.; Hell, E.N.F.; Scheller, H. The effect of optical conditioning of preparations with scan spray on preparation form. Acta Stomatol. Croat. 2011, 45, 86–92. [Google Scholar]
- Cook, K.T.; Fasbinder, D.J. Accuracy of CAD/CAM crown fit with infrared and LED cameras. Int. J. Comput. Dent. 2012, 15, 315–326. [Google Scholar]
- Mangano, F.; Gandolfi, A.; Luongo, G.; Logozzo, S. Intraoral scanners in dentistry: A review of the current literature. BMC Oral Health 2017, 17, 149. [Google Scholar] [CrossRef] [Scilit]
- Richert, R.; Goujat, A.; Venet, L.; Viguie, G.; Viennot, S.; Robinson, P.; Farges, J.-C.; Fages, M.; Ducret, M. Intraoral scanner technologies: A review to make a successful impression. J. Healthc. Eng. 2017, 2017, 8427595. [Google Scholar] [CrossRef] [Scilit]
- Zimmermann, M.; Mehl, A.; Mörmann, W.H.; Reich, S. Intraoral scanning systems–a current overview. Int. J. Comput. Dent. 2015, 18, 101–129. [Google Scholar]
- Borga Donmez, M.; Çakmak, G.; Dede, D.Ö.; Küçükekenci, A.S.; Lu, W.E.; Lang Schumacher, F.; Revilla-León, M.; Yilmaz, B. Effect of scan powder and scanning technology on measured deviations of complete-arch implant supported frameworks digitized with industrial and intraoral scanners. J. Dent. 2023, 138, 104736. [Google Scholar] [CrossRef] [Scilit]
- Jamjoom, F.Z.; Aldghim, A.; Aldibasi, O.; Yilmaz, B. In vitro evaluation of the impact of intraoral scanner, scanning aids, and the scanned arch on the scan accuracy of edentulous arches. J. Prosthodont. 2026, 35, 528–536. [Google Scholar] [CrossRef] [Scilit]
- Mie, G. Beiträge zur Optik trüber Medien, speziell kolloidaler Metallösungen. Ann. Phys. 1908, 330, 377–445. [Google Scholar] [CrossRef] [Scilit]
- Bohren, C.F.; Huffman, D.R. Absorption and Scattering of Light by Small Particles; Wiley: New York, NY, USA, 1983. [Google Scholar]
- Johnson, R.W.; Thiele, E.S.; French, R.H. Light-scattering efficiency of white pigments: An analysis of model core–shell pigments vs. optimized rutile TiO2. TAPPI J. 1997, 80, 233–239. [Google Scholar]
- Nicodemus, F.E. Directional reflectance and emissivity of an opaque surface. Appl. Opt. 1965, 4, 767–775. [Google Scholar] [CrossRef] [Scilit]
- Torrance, K.E.; Sparrow, E.M. Theory for off-specular reflection from roughened surfaces. J. Opt. Soc. Am. 1967, 57, 1105–1114. [Google Scholar] [CrossRef] [Scilit]
- Jensen, H.W.; Marschner, S.R.; Levoy, M.; Hanrahan, P. A practical model for subsurface light transport. In Proceedings of the SIGGRAPH 2001; ACM: New York, NY, USA, 2001; pp. 511–518. [Google Scholar] [CrossRef] [Scilit]
- Logozzo, S.; Zanetti, E.M.; Franceschini, G.; Kilpelä, A.; Mäkynen, A. Recent advances in dental optics–Part I: 3D intraoral scanners for restorative dentistry. Opt. Lasers Eng. 2014, 54, 203–221. [Google Scholar] [CrossRef] [Scilit]
- Geng, J. Structured-light 3D surface imaging: A tutorial. Adv. Opt. Photon. 2011, 3, 128–160. [Google Scholar] [CrossRef] [Scilit]
- Gorthi, S.S.; Rastogi, P. Fringe projection techniques: Whither we are? Opt. Lasers Eng. 2010, 48, 133–140. [Google Scholar] [CrossRef] [Scilit]
- Zhang, S. High-speed 3D shape measurement with structured light methods: A review. Opt. Lasers Eng. 2018, 106, 119–131. [Google Scholar] [CrossRef] [Scilit]
- Arksey, H.; O’Malley, L. Scoping studies: Towards a methodological framework. Int. J. Soc. Res. Methodol. 2005, 8, 19–32. [Google Scholar] [CrossRef] [Scilit]
- Tricco, A.C.; Lillie, E.; Zarin, W.; O’Brien, K.K.; Colquhoun, H.; Levac, D.; Moher, D.; Peters, M.D.J.; Horsley, T.; Weeks, L.; et al. PRISMA extension for scoping reviews (PRISMA-ScR): Checklist and explanation. Ann. Intern. Med. 2018, 169, 467–473. [Google Scholar] [CrossRef] [Scilit]
- Page, M.J.; McKenzie, J.E.; Bossuyt, P.M.; Boutron, I.; Hoffmann, T.C.; Mulrow, C.D.; Shamseer, L.; Tetzlaff, J.M.; Akl, E.A.; Brennan, S.E.; et al. The PRISMA 2020 Statement: An Updated Guideline for Reporting Systematic Reviews. BMJ 2021, 372, n71. [Google Scholar] [CrossRef] [Scilit]
- Sheth, V.H.; Shah, N.P.; Jain, R.; Bhanushali, N.; Bhatnagar, V. Development and validation of a risk-of-bias tool for assessing in vitro studies conducted in dentistry: The QUIN Tool. J. Prosthet. Dent. 2024, 131, 1038–1042. [Google Scholar] [CrossRef] [Scilit]
- Echhpal, U.R., 2nd; Ahmed, N.; Kiran, R. In vitro analysis of the accuracy of the use of waste zirconia dust compared with optical scanning spray on implant abutment models in extraoral scanning protocol. Cureus 2024, 16, e61633. [Google Scholar] [CrossRef] [Scilit]
- Rajab, R.R.; Jasim, H.H. Evaluation of the internal fit of zirconia crowns supported by metal implant abutments using different scanning aid agents through 3D analysis. J. Emerg. Med. Trauma Acute Care 2024, 2024, 19. [Google Scholar] [CrossRef] [Scilit]
- Alghazzawi, T.F.; Al-Samadani, K.H.; Lemons, J.; Liu, P.R.; Essig, M.E.; Bartolucci, A.A.; Janowski, G.M. Effect of imaging powder and CAD/CAM stone types on the marginal gap of zirconia crowns. J. Am. Dent. Assoc. 2015, 146, 111–120. [Google Scholar] [CrossRef] [Scilit]
- Vo, H.M.; Huynh, N.C.; Tran, T.T.; Hoang, H.T.; Nguyen, A.T. Influence of titanium dioxide and composite on the accuracy of an intraoral scanner for bilateral upper posterior edentulous jaw (Kennedy class I) scanning: An in vitro study. J. Dent. 2023, 139, 104747. [Google Scholar] [CrossRef] [Scilit]
- Hategan, S.; Gabor, A.; Zaharia, C.; Sinescu, C.; Negrutiu, M.L.; Jivanescu, A. Influence of Scanning System and Dentist’s Level of Training in the Accuracy of Digital Impressions. Proc. SPIE 2016, 9670, 967014. [Google Scholar] [CrossRef] [Scilit]
- Oh, H.S.; Lim, Y.J.; Kim, B.; Kim, W.H.; Kim, M.J.; Kwon, H.B. Influence of applied liquid-type scanning-aid material on the accuracy of the scanned image: An in vitro experiment. Materials 2020, 13, 2034. [Google Scholar] [CrossRef] [Scilit]
- Oh, H.S.; Lim, Y.J.; Kim, B.; Kim, M.J.; Kwon, H.B.; Baek, Y.W. Influence of scanning-aid materials on the accuracy and time efficiency of intraoral scanners for full-arch digital scanning: An in vitro study. Materials 2021, 14, 2340. [Google Scholar] [CrossRef] [Scilit]
- Cho, J.H.; Çakmak, G.; Yilmaz, B.; Yoon, H.I. Effect of CAD-CAM restorative materials and scanning aid conditions on the accuracy and time efficiency of intraoral scans. J. Prosthodont. 2023, 32, 608–615. [Google Scholar] [CrossRef] [Scilit]
- Zou, J.; Huang, K.; Chen, J.; Yin, L. Effects of liquid scanning-aid material and four variables on the scanning trueness of post space with intraoral scanning. J. Prosthet. Dent. 2026, 136, 1191–1199. [Google Scholar] [CrossRef] [Scilit]
- Dehurtevent, M.; Robberecht, L.; Béhin, P. Influence of dentist experience with scan spray systems used in direct CAD/CAM impressions. J. Prosthet. Dent. 2015, 113, 17–21. [Google Scholar] [CrossRef] [Scilit]
- Burde, A.V.; Dudea, D.; Cuc, S.; Moldovan, M.; Campian, R.S. Three-dimensional evaluations of the coating thickness of two optical conditioning scanning sprays. Mater. Plast. 2016, 53, 65–67. [Google Scholar]
- Kim, J.E.; Amelya, A.; Shin, Y.; Shim, J.S. Accuracy of intraoral digital impressions using an artificial landmark. J. Prosthet. Dent. 2017, 117, 755–761. [Google Scholar] [CrossRef] [Scilit]
- Chen, Y.; Zhai, Z.; Li, H.; Yamada, S.; Matsuoka, T.; Ono, S.; Nakano, T. Influence of liquid on the tooth surface on the accuracy of intraoral scanners: An in vitro study. J. Prosthodont. 2022, 31, 59–64. [Google Scholar] [CrossRef] [Scilit]
- An, H.; Mickesh, G.J.; Cho, D.; Sorensen, J.A. Effect of finish line location and saliva contamination on the accuracy of crown finish line scanning. J. Prosthodont. 2024, 33, 86–94. [Google Scholar] [CrossRef] [Scilit]
- Agustín-Panadero, R.; Moreno, D.M.; Pérez-Barquero, J.A.; Fernández-Estevan, L.; Gómez-Polo, M.; Revilla-León, M. Influence of type of restorative materials and surface wetness conditions on intraoral scanning accuracy. J. Dent. 2023, 134, 104521. [Google Scholar] [CrossRef] [Scilit]
- Ochsmann, E.; Brand, P.; Kraus, T.; Reich, S. Ultrafine particles in scanning sprays: A standardized examination of five powders used for dental reconstruction. J. Occup. Med. Toxicol. 2020, 15, 20. [Google Scholar] [CrossRef] [Scilit]
- U.S. Food and Drug Administration. 510(k) Summary K103586: IOS FastScan Spray (Predicate Device: CEREC Opti Spray, K080882); U.S. Food and Drug Administration: Silver Spring, MD, USA, 2011.
- Dentsply Sirona. CEREC Optispray Operating Instructions (Ref. 6687698, Document Version Dated 9 October 2023); Dentsply Sirona: Charlotte, NC, USA, 2023. [Google Scholar]
- Franke, J.; Koutecký, T.; Koutný, D. Comparison of sublimation 3D scanning sprays in terms of their effect on the resulting 3D scan, thickness, and sublimation time. Materials 2023, 16, 6165. [Google Scholar] [CrossRef] [Scilit]
- U.S. Patent Application Publication. Dry Shampoo Composition. US 2018/0153782 A1, 7 June 2018. [Google Scholar]
- International Patent Application Publication. Dry Shampoo Composition for Hair. WO 2015/071631 A1, 21 May 2015. [Google Scholar]
- Tester, R.F.; Karkalas, J.; Qi, X. Starch–composition, fine structure and architecture. J. Cereal Sci. 2004, 39, 151–165. [Google Scholar] [CrossRef] [Scilit]
- Uriciuc, W.A.; Boșca, A.B.; Băbțan, A.M.; Vermeșan, H.; Cristea, C.; Tertiș, M.; Pășcuță, P.; Borodi, G.; Suciu, M.; Barbu-Tudoran, L.; et al. Study on the surface of cobalt–chromium dental alloys and their behavior in oral cavity as cast materials. Materials 2022, 15, 3052. [Google Scholar] [CrossRef] [Scilit]
- Uriciuc, W.-A.; Suciu, M.; Barbu-Tudoran, L.; Botean, A.-I.; Chicinaș, H.-F.; Anghel, M.-A.; Popa, C.O.; Ilea, A. Surface treatments on cobalt–chromium alloys for layering ceramic paint coatings in dental prosthetics. Coatings 2025, 15, 833. [Google Scholar] [CrossRef] [Scilit]
- Jellison, G.E., Jr.; Cureton, W.K.; Arteaga, O. Optical functions of uniaxial rutile and anatase (TiO2) revisited. Surf. Sci. Spectra 2024, 31, 026001. [Google Scholar] [CrossRef] [Scilit]
- Palik, E.D. (Ed.) Handbook of Optical Constants of Solids; Academic Press: San Diego, CA, USA, 1985. [Google Scholar]
- ISO 12836:2015; Dentistry–Digitizing Devices for CAD/CAM Systems for Indirect Dental Restorations–Test Methods for Assessing Accuracy. International Organization for Standardization: Geneva, Switzerland, 2015.
- ISO 5725-1:2023; Accuracy (Trueness and Precision) of Measurement Methods and Results–Part 1: General Principles and Definitions. International Organization for Standardization: Geneva, Switzerland, 2023.
- Rupf, S.; Berger, H.; Buchter, A.; Harth, V.; Ong, M.F.; Hannig, M. Exposure of patient and dental staff to fine and ultrafine particles from scanning spray. Clin. Oral Investig. 2015, 19, 823–830. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.





