Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (29)

Search Parameters:
Keywords = three-phase four-wire inverter

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
17 pages, 2849 KB  
Article
Multi-Fault Diagnosis of Three-Phase Four-Wire Inverter Based on Fuzzy Logic
by Jian Huang, Yuan Sun, Heping Fu, Guan Wang, Zuosheng Yin, Kai Cui and Chao Zhang
Energies 2026, 19(13), 2953; https://doi.org/10.3390/en19132953 - 23 Jun 2026
Viewed by 334
Abstract
In modern power systems such as new energy generation and smart grids, inverters serve as core equipment for electrical energy conversion and transmission. Their operational reliability directly impacts system power supply quality and safety stability. Currently, research on inverter fault diagnosis technology primarily [...] Read more.
In modern power systems such as new energy generation and smart grids, inverters serve as core equipment for electrical energy conversion and transmission. Their operational reliability directly impacts system power supply quality and safety stability. Currently, research on inverter fault diagnosis technology primarily focuses on linear load conditions, with diagnostic method design and validation based on linear load characteristics. However, with the rapid advancement of power electronics technology, power electronic loads such as variable frequency drives, charging stations, and distributed power sources are increasingly prevalent in power systems. These loads exhibit nonlinear and time-varying characteristics under complex operating conditions, leading to a growing variety of inverter faults with significantly diversified and complex fault signatures. Traditional diagnostic methods fail to adapt to the unique characteristics of power electronic loads, making it difficult to accurately identify various faults. Consequently, they no longer meet the diagnostic demands of practical engineering scenarios. In addition, current diagnostic methods for open-circuit power transistors, intermittent faults, and sensor faults often employ different approaches, which consume significant controller resources and are prone to mutual interference, leading to false triggers. This paper takes a three-phase four-wire inverter as the research subject. Targeting the challenge of fault diagnosis under power electronic load conditions, it proposes a comprehensive diagnostic method capable of simultaneously diagnosing power switch open circuits, intermittent faults, and current sensor faults. First, the characteristics of various faults are analyzed. Subsequently, fault diagnosis variables are constructed using the actual arm voltage of the inverter and the ideal arm voltage. Logical rules for each type of fault are established, and diagnosis is performed through fuzzy logic inference. Finally, experiments validated the effectiveness of this fault diagnosis scheme, with open-circuit faults detected in less than 2 ms, intermittent faults in less than 0.5 ms, and sensor faults in less than 3 ms. Full article
(This article belongs to the Section F3: Power Electronics)
Show Figures

Figure 1

35 pages, 4901 KB  
Article
Investigation of the Impact of Household Energy Storage on DSO Grid Load Symmetry and Photovoltaic Energy Utilization Efficiency
by Laurynas Šriupša, Mindaugas Vaitkūnas, Artūras Baronas, Gytis Svinkūnas, Julius Dosinas, Saulius Gudžius and Gytis Vilutis
Symmetry 2026, 18(5), 879; https://doi.org/10.3390/sym18050879 - 21 May 2026
Viewed by 346
Abstract
In this study, we investigate the impact of electric energy storage (EES) on phase line power flow symmetry and photovoltaic (PV) energy utilization in prosumer three-phase four-wire integrated household systems. The analysis is based on high-time-resolution (1 s) experimental data collected from a [...] Read more.
In this study, we investigate the impact of electric energy storage (EES) on phase line power flow symmetry and photovoltaic (PV) energy utilization in prosumer three-phase four-wire integrated household systems. The analysis is based on high-time-resolution (1 s) experimental data collected from a real household grid and subsequent simulations of energy flows using MATLAB/Simulink software. Two converter operation strategies were evaluated: the conventional symmetric mode and the asymmetric mode developed by the authors based on an adaptive power flow management algorithm. For both strategies, the impact of EES capacity on imbalance in the distribution system operator (DSO) grid was investigated. The methodology analyzes energy flows in each phase line separately, allowing for a detailed assessment of the imbalance between phase line phenomena and their impact on local energy consumption. Key performance parameters used for the efficiency evaluation include the self-consumption and self-sufficiency rates, which quantify the share of locally generated energy consumed within the household and the degree of independence from the DSO grid. The results show that combining adaptive asymmetric inverter control with appropriately sized energy storage allows for more efficient on-site utilization of PV energy, which, at the same time, improves the load symmetry of the phase lines in the DSO grid. Full article
Show Figures

Figure 1

36 pages, 3098 KB  
Review
Voltage Regulation in Rooftop PV-Rich Distribution Networks: A Review and Detailed Case Study
by Obaidur Rahman, Sean Elphick and Duane A. Robinson
Electronics 2026, 15(5), 1074; https://doi.org/10.3390/electronics15051074 - 4 Mar 2026
Cited by 2 | Viewed by 1527
Abstract
The increasing penetration of rooftop photovoltaic (PV) systems has introduced significant challenges to voltage regulation and power quality within low voltage (LV) distribution networks. Reverse power flows during periods of high solar generation and low local demand can lead to overvoltage issues, voltage [...] Read more.
The increasing penetration of rooftop photovoltaic (PV) systems has introduced significant challenges to voltage regulation and power quality within low voltage (LV) distribution networks. Reverse power flows during periods of high solar generation and low local demand can lead to overvoltage issues, voltage unbalance, and increased neutral-to-ground potential. This paper presents a comprehensive review of voltage regulation challenges and mitigation strategies for PV-rich distribution networks. The review consolidates findings from recent literature, focusing on traditional methods such as on-load tap changers and reactive power compensation, as well as modern techniques including smart inverter functionalities, community energy storage, static compensators, and advanced coordinated control schemes. A detailed examination of the suitability and limitations of these approaches in the Australian regulatory and network context is provided. The literature review demonstrates that previous work has mainly considered generic LV regulation issues without explicit four-wire MEN modelling or detailed LV–MV time series impact analysis. As a response to the lack of detailed practical analysis, a detailed three-phase four-wire LV–MV modelling and case study analysis, which illustrates the technical implications of high PV penetration on a representative Australian LV feeder, has been completed. The network is modelled using a three-phase four-wire unbalanced load flow formulation, explicitly incorporating the neutral conductor and multiple earthed neutral (MEN) system configuration. Results demonstrate pronounced voltage rise and unbalance during midday generation periods, highlighting the need for distributed and adaptive voltage-management solutions. The paper concludes by identifying key research gaps and future directions for voltage regulation in Australian distribution networks, emphasizing the importance of low voltage visibility, coordinated control architectures, and the integration of emerging distributed energy resources. The novelty of this work lies in combining a focused review of state-of-the-art with respect to management of voltage regulation in the presence of high penetration of distributed PV generation with a detailed three-phase four-wire LV–MV modelling framework and time-series case study of a representative Australian residential feeder, which illustrates the practical implications of increasing PV penetration. Full article
Show Figures

Figure 1

15 pages, 1740 KB  
Article
Receiving-End Voltage Compensation Method with NPC-Inverter-Based Active Power Line Conditioner in Three-Phase Four-Wire Distribution Feeder
by Yuka Sabi and Hiroaki Yamada
Electricity 2024, 5(4), 770-784; https://doi.org/10.3390/electricity5040038 - 30 Oct 2024
Viewed by 1920
Abstract
This study proposes a receiving-end voltage compensation method employing a phase-specific reactive power control strategy with a neutral-point-clamped (NPC) inverter in a three-phase four-wire distribution system. The principle of the proposed receiving end voltage compensation method is explained. Further, the proposed control strategy [...] Read more.
This study proposes a receiving-end voltage compensation method employing a phase-specific reactive power control strategy with a neutral-point-clamped (NPC) inverter in a three-phase four-wire distribution system. The principle of the proposed receiving end voltage compensation method is explained. Further, the proposed control strategy can solve the problems of the three-phase, four-wire distribution system, which are an increase in the neutral-line current and the unbalanced voltage. Computer simulation is performed to confirm the validity of the proposed method. The simulation results indicate the receiving-end voltages can be compensated using the proposed method. Full article
Show Figures

Figure 1

19 pages, 6455 KB  
Article
An Energy-Feed Type Split-Capacitor Three-Phase Four-Wire Power Electronic Load Compatible with Various Load Demands
by Shiyi Sun, Qingjun Huang, Bingyang Luo, Jianghua Lu, Jiapeng Luo, Zexu Ma and Guorong Zhu
Energies 2024, 17(1), 119; https://doi.org/10.3390/en17010119 - 25 Dec 2023
Cited by 2 | Viewed by 2282
Abstract
Energy-feed power electronic loads can precisely control the phase and magnitude of the power supply output current, achieving the emulation of loads. Moreover, they can feed energy back to the grid for energy regeneration, demonstrating significant research value. This article proposes an energy-fed [...] Read more.
Energy-feed power electronic loads can precisely control the phase and magnitude of the power supply output current, achieving the emulation of loads. Moreover, they can feed energy back to the grid for energy regeneration, demonstrating significant research value. This article proposes an energy-fed power electronic load topology and control method that can realize the static and dynamic simulation of linear and non-linear loads and take into account the simulation needs of single-phase, three-phase three-wire, and three-phase four-wire loads. The main circuit uses a two-stage back-to-back AC/DC/AC structure: the front side is a three-phase four-wire split capacitor PWM rectifier bridge, which is used to simulate loads under various operating conditions; the back side is a three-phase three-wire PWM inverter bridge, which realizes the energy feeding back to the grid and reduces the waste of energy; and the intermediate side uses a split capacitor to equalize the voltage and achieve voltage stabilization. The topology is analyzed under the simulation demands of three-phase balanced, three-phase unbalanced, single-phase and non-linear loads. Finally, a MATLAB(R2022a)/Simulink simulation platform is built for a power electronic load with a rated capacity of 200 kVA. The simulation results verify the effectiveness, feasibility, and advancement of the power electronic load proposed in this article. Full article
(This article belongs to the Special Issue Advances in Power Electronics Technologies)
Show Figures

Figure 1

15 pages, 10925 KB  
Article
Analysis of the Mechanism and Control of the Unbalanced Operation of Three-Phase Four-Wire Inverters
by Fuzhuan Wu, Binyu Miao, Sheng Peng, ManMan Li and Shengjun Wen
Appl. Sci. 2023, 13(22), 12253; https://doi.org/10.3390/app132212253 - 12 Nov 2023
Cited by 2 | Viewed by 3364
Abstract
In this paper, a solution is proposed to the problem of the unequal phase imbalance of output voltage caused by a three-phase, four-wire, split capacitor inverter when the load is unbalanced. First, the triple-loop control strategy was used to solve the unequal amplitude [...] Read more.
In this paper, a solution is proposed to the problem of the unequal phase imbalance of output voltage caused by a three-phase, four-wire, split capacitor inverter when the load is unbalanced. First, the triple-loop control strategy was used to solve the unequal amplitude problem. This method used the feedforward + feedback composite control strategy on the inductor current inner-loop and voltage mid-loop to decrease the disturbance of the power and load. And the Root Mean Square (RMS) of voltage on the outer-loop completed the control of amplitude for the three-phase voltage. Second, to solve the imbalanced phase problem, the imbalance operation mechanism of the three-phase four-wire inverter was analyzed. It is known from the analysis that the phase imbalance is related to the DC-side splitting capacitance. The function relations between the DC-side capacitance and phase angle between each phase was simulated by MATLAB. But, it was too complicated to calculate the magnitude of the capacitance value through the functional relationship. In order to simplify the design of the DC-side splitting capacitor, the relations among the imbalanced current, the voltage fluctuations of the DC-side capacitor and the harmonics of load voltage were analyzed. In addition, by following the requirement of the national standard about the harmonics of load voltage, a DC-side capacitor design was mentioned to decrease the influence of imbalanced phase. Finally, simulation and experimental results show that the three-phase load voltage is stable, the THD value is less than 3%, and three-phase voltage unbalance is less than 2%, thus verifying the effectiveness of the proposed DC-side split capacitor design and control strategy. Full article
(This article belongs to the Section Electrical, Electronics and Communications Engineering)
Show Figures

Figure 1

19 pages, 10910 KB  
Article
Research into a Method of Forming Neutral Point Voltage in a Three-Phase Four-Wire Voltage Inverter
by Andrey Dar’enkov, Andrey Kurkin, Anton Sluzov, Ivan Berdnikov, Anton Khramov and Andrey Shalukho
Energies 2023, 16(15), 5739; https://doi.org/10.3390/en16155739 - 1 Aug 2023
Cited by 2 | Viewed by 2904
Abstract
Three-phase four-wire voltage inverters are commonly used in energy complexes based on distributed generation sources (solar panels, wind power plants, hydrogen fuel cells) and accumulator batteries. They allow to power loads, including single-phase ones, which require neutral point connection. In these cases, phase [...] Read more.
Three-phase four-wire voltage inverters are commonly used in energy complexes based on distributed generation sources (solar panels, wind power plants, hydrogen fuel cells) and accumulator batteries. They allow to power loads, including single-phase ones, which require neutral point connection. In these cases, phase voltage formed by spatial pulse-width modulation (PWM) methods considerably differs from sinusoidal waves and has high total harmonic distortions of voltage and current curves. This article is devoted to research into the authors’ control method of a three-phase four-wire inverter, allowing for the rectification of the form of phase voltage supplying the load when applying the most common PWM (SVPWM, DPWMMIN, DPWMMAX, GDPWM) methods. The description of the method and its research results by simulation modeling and test bench are presented in the article. The simulation modeling was carried out by the developed Simulink-model of the three-phase four-wire inverter and its control system. The modeling results showed that the method application ensures sinusoidal voltage form when applying any PWM method. At this, THDU was reduced from 21.56% to 4.39%, while THDI was reduced from 21.16% to 1.69%. Experimental tests were carried out by a test bench featuring an uninterruptible power supply source. The authors researched the inverter operation as a component of the test bench under the control of the proposed method to form neutral point voltage. The experimental test results coincided with the simulation modeling results. Full article
(This article belongs to the Section F3: Power Electronics)
Show Figures

Figure 1

23 pages, 11230 KB  
Article
Oscillation Suppression Strategy of Three-Phase Four-Wire Grid-Connected Inverter in Weak Power Grid
by Guoli Feng, Zhihao Ye, Yihui Xia, Heng Nian and Yunxiang Jiang
Electronics 2023, 12(14), 3105; https://doi.org/10.3390/electronics12143105 - 17 Jul 2023
Cited by 1 | Viewed by 2116
Abstract
As the penetration of renewable energy increases year by year, the risk of high-frequency oscillation instability increases when a three-phase, four-wire split capacitor inverter (TFSCI) is connected to the grid with complementary capacitors in weak grids. Compared to the three-phase, three-wire inverter, the [...] Read more.
As the penetration of renewable energy increases year by year, the risk of high-frequency oscillation instability increases when a three-phase, four-wire split capacitor inverter (TFSCI) is connected to the grid with complementary capacitors in weak grids. Compared to the three-phase, three-wire inverter, the TFSCI has an additional zero-sequence current loop. To improve the accuracy of the modeling and stability analysis, the effect of the zero-sequence loop needs to be considered in the impedance-based stability analysis. Therefore, a correlation model considering multi-perturbation variables is first established, based on which the inverter positive, negative, and zero sequence admittance models are derived, solving the difficult problem of impedance modeling under small perturbations. Secondly, an admittance remodeling strategy based on a negative third-order differential element and a second-order generalized integrator (SOGI) damping controller is proposed, which can improve the stability of positive, negative, and zero-sequence systems simultaneously. Finally, the effectiveness of the oscillation suppression strategy is verified by simulation and experiment. Full article
(This article belongs to the Special Issue Applications, Control and Design of Power Electronics Converters)
Show Figures

Figure 1

14 pages, 2953 KB  
Article
Modelling of Bidirectional Three-Phase Four-Wire Three-Level NPC MLC under Single-Loop Current Sensorless Control
by Alexander Suzdalenko, Vsevolod Burenin, Jaroslavs Zarembo and Janis Zakis
Energies 2023, 16(12), 4599; https://doi.org/10.3390/en16124599 - 8 Jun 2023
Cited by 2 | Viewed by 2385
Abstract
Single-loop current sensorless control allows for abolishing of the instantaneous current measurement in the control system using only a single control loop with voltage feedback to stabilise the DC-bus voltage. This approach eliminates current sensors in the control circuit, benefiting from saving space [...] Read more.
Single-loop current sensorless control allows for abolishing of the instantaneous current measurement in the control system using only a single control loop with voltage feedback to stabilise the DC-bus voltage. This approach eliminates current sensors in the control circuit, benefiting from saving space on the printed circuit board and minimising power dissipation in the current measurement circuitry. This paper focuses on the single-loop current sensorless control applied to bidirectional three-phase four-wire three-level NPC MLC by simulation analysis and demonstrates the performance of the proposed current control algorithm in the rectifier and inverter modes and the step response with power direction change and grid-voltage change. In capacitor voltage balancing, an additional controller is applied, which is capable of compensating for the voltage asymmetry caused by adding a 2.5 kOhm resistor in parallel to one of the DC-bus capacitors. Our results demonstrate good performance of the proposed control method both in the inverter and rectifier modes, showing stable current shape in the low power and full power modes with acceptable harmonics content, meeting the requirements of the IEC 61000-3-2 standard for Class A devices. The analysis showed that the proposed control approach is suitable for industrial application. Full article
Show Figures

Figure 1

13 pages, 9477 KB  
Article
Sensorless Current Pulsation Compensation in a Hybrid Energy Storage
by Karol Fatyga and Dariusz Zieliński
Appl. Sci. 2023, 13(4), 2252; https://doi.org/10.3390/app13042252 - 9 Feb 2023
Cited by 3 | Viewed by 1778
Abstract
This paper presents a dual active bridge DC/DC converter used as an AC current compensator in a hybrid energy storage application. The AC current in the DC link appears when a three-phase, four-wire inverter operates with unbalanced output currents—for example, when trying to [...] Read more.
This paper presents a dual active bridge DC/DC converter used as an AC current compensator in a hybrid energy storage application. The AC current in the DC link appears when a three-phase, four-wire inverter operates with unbalanced output currents—for example, when trying to compensate for grid voltage unbalance. This AC current has adverse effects on the operation of the electrochemical energy storage, and it should be compensated. To achieve this, a compensator is introduced into the DC link circuit of the inverter—a DC/DC converter with a capacitor bank. The DC/DC converter is responsible for compensating the AC pulsation by creating its own pulsation with the opposite phase. In the paper, the genesis of this pulsation is explained, and a compensation circuit is proposed along with a sensorless compensation algorithm. The algorithm is based on symmetrical decomposition and is used to generate a reference signal for the compensator. The numerical analysis of the algorithm is presented, and the operation of the compensator is verified on the laboratory bench. Full article
(This article belongs to the Collection Advanced Power Electronics in Power Networks)
Show Figures

Figure 1

19 pages, 4576 KB  
Article
A Generalized Approach for Determining the Current Ripple RMS in Four-Leg Inverters with the Neutral Inductor
by Riccardo Mandrioli, Francesco Lo Franco, Mattia Ricco and Gabriele Grandi
Energies 2023, 16(4), 1710; https://doi.org/10.3390/en16041710 - 8 Feb 2023
Cited by 3 | Viewed by 3076
Abstract
This manuscript proposes a novel approach for determining phase and neutral-current-ripple RMS in grid-connected four-leg inverters with the neutral inductor. The harmonic pollution is determined for any arbitrary pulse width modulation (PWM) technique and a generic value of the neutral inductor. Thanks to [...] Read more.
This manuscript proposes a novel approach for determining phase and neutral-current-ripple RMS in grid-connected four-leg inverters with the neutral inductor. The harmonic pollution is determined for any arbitrary pulse width modulation (PWM) technique and a generic value of the neutral inductor. Thanks to the proposed approach, it is possible to describe the neutral inductor in a parametric way with respect to phase inductors and obtain a wide range of results, ranging from a direct neutral connection (no neutral inductor) to a conventional three-phase inverter (no fourth wire) for any value of modulation index and common mode injection. The results permit one to compare different design choices in multiple scenarios effectively. The findings were validated by numerical simulations and experimental tests employing the most popular PWM techniques, such as space vector PWM (SVPWM) and discontinuous PWM (DPWM). Full article
(This article belongs to the Special Issue Progress in Design and Control of Power Converters)
Show Figures

Figure 1

23 pages, 13731 KB  
Article
Stability Analysis and Robust Control Method for LCL-Type Three-Phase Four-Wire Split Capacitor Inverter Considering Zero-Sequence Loop
by Longyue Yang, Tian Cao, Zhipeng Cai, Xuejing Xia, Chenxi Jia, Xinwei Dong and Shuyuan Zhang
Electronics 2022, 11(20), 3286; https://doi.org/10.3390/electronics11203286 - 12 Oct 2022
Cited by 4 | Viewed by 3147
Abstract
In distributed generation systems, the inverter is the main power interface and its stability directly determines the reliable operation of the grid-connected system. As a typical topology for a three-phase four-wire inverter, the LCL-type three-phase four-wire split capacitor inverter (LCL-TFSCI) is taken as [...] Read more.
In distributed generation systems, the inverter is the main power interface and its stability directly determines the reliable operation of the grid-connected system. As a typical topology for a three-phase four-wire inverter, the LCL-type three-phase four-wire split capacitor inverter (LCL-TFSCI) is taken as the research subject of this paper. Compared with the three-phase three-wire inverter, there is an additional zero-sequence path in the LCL-TFSCI. Therefore, it is not only necessary to consider the stability of the positive and negative sequence system, but there is also the need to consider the stability of the zero-sequence system when performing stability analysis for the LCL-TFSCI. In this paper, a small-signal impedance model considering the zero-sequence loop of LCL-TFSCI is firstly established. Subsequently, the instability risk is revealed when LCL-TFSCI is connected to the grid with parallel compensation capacitors. Through instability analysis, an impedance-reshaping method based on the complex filter and combined differential elements is proposed, which can reshape the impedance characteristic of LCL-TFSCI within the wide frequency range and expand the stability domain of the grid-connected system. Finally, the proposed method is verified by simulation and experiment. Full article
(This article belongs to the Special Issue Application of Power Electronics Technology in Energy System)
Show Figures

Figure 1

21 pages, 8612 KB  
Article
Performance Comparisons of Three-Phase/Four-Wire Model Predictive Control-Based DC/AC Inverters Capable of Asymmetric Operation for Wave Energy Converters
by Chan Roh
Energies 2022, 15(8), 2839; https://doi.org/10.3390/en15082839 - 13 Apr 2022
Cited by 9 | Viewed by 3006
Abstract
A study on the capacity increase of a power converter according to the increase in the single capacity of wave energy converters and four-leg topology that can supply stable power even under unbalanced load conditions during independent operation is required. Therefore, in this [...] Read more.
A study on the capacity increase of a power converter according to the increase in the single capacity of wave energy converters and four-leg topology that can supply stable power even under unbalanced load conditions during independent operation is required. Therefore, in this paper, the performances of various four-leg inverters, from two-level inverters to three-level inverters, which are used as power converters for wave energy converters, are compared respectively. Since the four-leg converter has an unusual structure, the performance of each four-leg inverter was analyzed by applying the model predictive control that can easily and simply configure the controller. To verify the performance of each four-leg inverter, a comparison was performed under balanced load and unbalanced load conditions. Based on this, a suitable four-leg topology of the power converter for wave energy converters was confirmed. Full article
(This article belongs to the Special Issue Marine Renewable Energy Technology)
Show Figures

Figure 1

26 pages, 10913 KB  
Article
Impedance Modeling and Stability Analysis of Three-Phase Four-Wire Inverter with Grid-Connected Operation
by Guoli Feng, Zhihao Ye, Yihui Xia, Liming Huang and Zerun Wang
Energies 2022, 15(8), 2754; https://doi.org/10.3390/en15082754 - 8 Apr 2022
Cited by 8 | Viewed by 3412
Abstract
With the continuous penetration and development of renewable energy power generation, distributed grids and microgrids are becoming increasingly important in power systems. In the distribution networks and microgrids, the grid impedance is comparatively large and cannot be ignored. Usually, the parallel compensation is [...] Read more.
With the continuous penetration and development of renewable energy power generation, distributed grids and microgrids are becoming increasingly important in power systems. In the distribution networks and microgrids, the grid impedance is comparatively large and cannot be ignored. Usually, the parallel compensation is used to improve the grid quality. In these three-phase four-wire power systems, analyzing the impedance characteristics of the grid-connected inverter is vital to carry out the small-signal stability analysis. Thus, it is vital to consider the influence of the zero-sequence component in addition to the positive-sequence component and the negative-sequence component when it comes to analyzing system stability. In this paper, the impedances of three-phase four-wire split capacitor inverter and three-phase four-leg inverter are established. Based on the achieved impedance, the similarities and differences between the impedances of three-phase four-wire split capacitor inverter and impedance of three-phase four-leg inverter are studied. The main difference is reflected in zero-sequence impedance. Additionally, the zero-sequence impedance characteristics and the dominating factors deciding the zero-sequence impedance are analyzed. Then, the stability of the system considering the grid impedance and impedance of three-phase four-wire inverter is investigated by separately considering the stability of the positive–negative-sequence component and the stability of the zero-sequence component. Several cases of small-signal instability caused by the positive–negative-sequence component or zero-sequence component are revealed. The experimental results validate the theoretical analysis. Full article
(This article belongs to the Section F: Electrical Engineering)
Show Figures

Figure 1

20 pages, 10168 KB  
Article
High Frequency Resonance Suppression Strategy of Three-Phase Four-Wire Split Capacitor Inverter Connected to Parallel Compensation Grid
by Guoli Feng, Zhihao Ye, Yihui Xia, Heng Nian, Liming Huang and Zerun Wang
Energies 2022, 15(4), 1486; https://doi.org/10.3390/en15041486 - 17 Feb 2022
Cited by 3 | Viewed by 2750
Abstract
With the continuous penetration and development of renewable energy power generation, the distributed grid and the microgrid are becoming increasingly important in modern power systems. In distribution networks and the microgrid, the grid impedance is comparatively large and cannot be ignored. Usually, the [...] Read more.
With the continuous penetration and development of renewable energy power generation, the distributed grid and the microgrid are becoming increasingly important in modern power systems. In distribution networks and the microgrid, the grid impedance is comparatively large and cannot be ignored. Usually, the parallel compensation is used to improve the grid quality. In the grid with parallel compensation, the large phase angle difference between the impedance of the grid-connected inverter and the impedance of the grid at amplitude intersection will result in high frequency resonance (HFR). Because the inverter shows filter characteristics due to limited bandwidth of the controller, the parallel compensation grid, respectively, performs as the capacitance characteristic and inductance characteristic in different high frequency range. Compared with the three-phase, three-wire system, an additional zero-sequence path exists in the three-phase four-wire split capacitor inverter (TFSCI) system, so that the existing high frequency resonance suppression methods will be not effective. Since the zero-sequence component is neglected, HFR will also occur, in addition to the positive-sequence component and the negative-sequence component. Therefore, in order to suppress the high frequency resonance caused by positive-sequence, negative-sequence and zero-sequence components, an impedance reshaping strategy based on current feedback is proposed in this paper. This proposed method can reshape the amplitude and phase of the inverter impedance in a high frequency range without affecting the performance of the fundamental frequency control and ensure that the inverter contains a sufficient phase margin. Additionally, the proposed method can reshape the impedance of TFSCI within a wide frequency range, which makes it able to cope with the challenge of the parallel compensation degree change. Theoretical analysis and experiments verify the availability of the proposed control strategy. Full article
Show Figures

Figure 1

Back to TopTop