Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (45)

Search Parameters:
Keywords = International System of Units (SI)

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
28 pages, 501 KB  
Article
Charged Lepton Masses from the Recognition Composition Law: A Derivation with Zero Continuously Adjustable Dimensionless Parameters
by Jonathan Washburn and Elshad Allahyarov
Symmetry 2026, 18(6), 962; https://doi.org/10.3390/sym18060962 - 2 Jun 2026
Viewed by 274
Abstract
We derive the charged-lepton mass chain from the Recognition Composition Law (RCL) together with normalization, curvature normalization, and standard regularity. Through the theorem chain Tr1–Tr8, these postulates fix the golden ratio φ = 1+5/2, the minimal [...] Read more.
We derive the charged-lepton mass chain from the Recognition Composition Law (RCL) together with normalization, curvature normalization, and standard regularity. Through the theorem chain Tr1–Tr8, these postulates fix the golden ratio φ = 1+5/2, the minimal period Tmin = 8, the selected dimension D = 3, and the cube integers entering the master mass law. The charged-lepton formula is then assembled from the coherence scale, the lepton-sector baseline, the charge correction, and the derived generation steps. All parameters are discrete structural inputs, integers from cube geometry, named symmetry factors, and one external mathematical constant, rather than continuously adjustable dials. The construction is a structural constraint on the effective charged-lepton flavor pattern, not a replacement for the electroweak Higgs mechanism or for the full Standard Model quantum field theory. At the conversion stage to the International System of Units (SI), the electron fixes the single calibration anchor τ0, while the fine-structure constant α enters only as a fixed external dimensionless constant in the refinement layer. The phrase “zero continuously adjustable parameters” refers to the dimensionless content of the framework: the anchor τ0 is a unit-scale calibration fixed by the measured electron mass and cancels identically from every charged-lepton mass ratio. With that one anchor set, the remaining charged leptons become forward predictions: mμ105.5,105.9  MeV and mτ1774,1779 MeV, with relative errors below 0.3% and 0.2%, respectively. Floating-point evaluation gives mμ105.658 MeV and mτ1776.71 MeV. Full article
(This article belongs to the Section C: Physics)
Show Figures

Figure 1

23 pages, 6547 KB  
Article
Validation of SLSTR Sea Surface Temperature (SST) with Global Ships4sst L2R Data
by Werenfrid Wimmer, Tim Nightingale, Arrow Lee, Jacob Høyer, Guisella Gacitúa, Ruth Wilson, Sorrel Nelson and Craig James Donlon
Remote Sens. 2026, 18(10), 1487; https://doi.org/10.3390/rs18101487 - 9 May 2026
Viewed by 414
Abstract
SST data derived from multi-spectral infrared measurements made by the SLSTR instruments onboard the Copernicus Sentinel-3 satellites are considered reference measurements based on the design features of the SLSTR instrument. This means that regular long-term validation of the end-to-end performance using independent reference [...] Read more.
SST data derived from multi-spectral infrared measurements made by the SLSTR instruments onboard the Copernicus Sentinel-3 satellites are considered reference measurements based on the design features of the SLSTR instrument. This means that regular long-term validation of the end-to-end performance using independent reference data is essential. This paper presents a sustained SLSTR SST validation activity between 2018 and 2025 based on an extensive set of near-contemporaneous and co-located in situ reference measurements. In situ measurements are derived from high-performance shipborne infrared radiometers that are calibrated regularly against International System of Units (SI) reference standards maintained by a National Metrology Institute (NMI). As such, they are classified as FRMs. The shipborne radiometers are operated by several organizations that co-operate within the International Shipborne FRM Radiometer Network (ISFRN), under the auspices of the European Space Agency (ESA) ships4sst project (a quasi-operational SSTskin measurement program with a common data format and traceable measurements). The mean measured differences between the SLSTR on Sentinel-3A (S3A) and the ships4sst FRM data are 0.01 K with a RSD of 0.20 K for nighttime retrievals and 0.07 K with an RSD of 0.27 K for daytime retrievals. For Sentinel-3B (S3B), the mean measured differences between the SLSTR and the ships4sst data are 0.04 K with an RSD of 0.19 K for nighttime retrievals, and 0.03 K with an RSD of 0.27 K for daytime retrievals. Our comparisons validate the consistency and performance of the Copernicus Sentinel-3 SLSTR SST data and provide the means to link these satellite measurements to NMI reference standards, which is essential for justifying the status of SLSTR SST data as a CDR. Full article
Show Figures

Figure 1

24 pages, 8735 KB  
Article
Evaluation of High Dynamic Range Imaging Methods for Luminance Measurements
by Lou Gevaux, Alejandro Ferrero, Alice Dupiau, Ángela Sáez, Markos Antonopoulos and Constantinos Bouroussis
J. Imaging 2026, 12(3), 114; https://doi.org/10.3390/jimaging12030114 - 9 Mar 2026
Viewed by 1298
Abstract
Imaging luminance measurement is increasingly used in lighting applications, but the limited dynamic range of camera sensors requires using high dynamic range (HDR) imaging methods for evaluating scenes with large luminance contrasts. This work aims at investigating how parameters of HDR imaging techniques [...] Read more.
Imaging luminance measurement is increasingly used in lighting applications, but the limited dynamic range of camera sensors requires using high dynamic range (HDR) imaging methods for evaluating scenes with large luminance contrasts. This work aims at investigating how parameters of HDR imaging techniques may impact luminance measurement accuracy, using a numerical evaluation. A numerical simulation framework based on a digital twin of an imaging system and synthetic high-contrast luminance scenes is used to introduce controlled systematic error sources and quantify their impact on HDR luminance accuracy. The results support the identification of HDR approaches most suitable for producing luminance measurements traceable to the International System of Units (SI). Full article
(This article belongs to the Section Computational Imaging and Computational Photography)
Show Figures

Figure 1

31 pages, 8292 KB  
Article
Flexural Performance of Geopolymer-Based Composite Beams Under Different Curing Regimes
by Feyyaz Unver, Mucteba Uysal, Beyza Aygun, Turhan Bilir, Turgay Cosgun, Mehmet Safa Aydogan and Guray Arslan
Buildings 2026, 16(2), 439; https://doi.org/10.3390/buildings16020439 - 21 Jan 2026
Cited by 2 | Viewed by 658
Abstract
Electrical curing is a viable alternative to traditional thermal curing for geopolymer materials due to its capability for rapid and internal geopolymerization. In this research, reinforced geopolymer-based composite beams were successfully fabricated at a macroscale using a binary system of fly ash (FA) [...] Read more.
Electrical curing is a viable alternative to traditional thermal curing for geopolymer materials due to its capability for rapid and internal geopolymerization. In this research, reinforced geopolymer-based composite beams were successfully fabricated at a macroscale using a binary system of fly ash (FA) and granulated blast furnace slag (GBFS). The mixture was activated with a solution of sodium silicate (Na2SiO3) and sodium hydroxide (NaOH) with a fixed molar ratio of 2:1 for both, and aggregate-to-binder and activator-to-binder (A/B) ratios of 2.5 and 0.7, respectively. To ensure electrical conductivity, individual fiber systems were employed, including carbon fiber (CF), steel fiber (SF), and waste wire erosion (WWE), each incorporated at a dosage of 0.5 vol.% of the total mix volume. In addition, carbon black (CB) was introduced as a conductive filler at a constant dosage of 2.0 vol.% of the binder content in selected specimens. Each beam specimen contained only one type of conductive reinforcement or filler. A total of twelve reinforced geopolymer-based composite beams with a 150 mm square section and a span of 1300 mm, with a clear span of 1200 mm, were successfully cast and reinforced based on reinforced concrete beam designs and standards, with a dominant goal of enhancing beam behavior under flexure. The beams were cured in ambient curing conditions, or using thermal curing at 80 °C for 24 h, and using electrical curing from the fresh states with a fixed voltage of 25 V. Notwithstanding a common beam size and reinforcement pattern, distinct curing methods significantly influenced beam structure properties. Peak loads were between 20.8 and 31.5 kN, initial stiffness between 1.75 and 6.09 kN/mm, and total energy absorption between 690 and 1550 kN/mm, with a post-peak energy component of between 0.12 and 0.55. Displacement-based ductility measures spanned from 3.2 to 8.1 units with a distinct improvement in electrical curing regimes, especially in the SF-reinforced specimens; this indicates that electrical curing in reinforced geopolymer composite materials works as a governing mechanism in performance rather than simply a method for enhancing the strength of materials. Full article
Show Figures

Figure 1

18 pages, 5147 KB  
Technical Note
Assessment of Instrument Performance of the FY3E/JTSIM/DARA Radiometer Through the Analysis of TSI Observations
by Jean-Philippe Montillet, Wolfgang Finsterle, Ping Zhu, Margit Haberreiter, Silvio Koller, Daniel Pfiffner, Duo Wu, Xin Ye, Dongjun Yang, Wei Fang, Jin Qi and Peng Zhang
Remote Sens. 2025, 17(23), 3902; https://doi.org/10.3390/rs17233902 - 30 Nov 2025
Cited by 1 | Viewed by 753
Abstract
Since the late 1970s, satellite missions have monitored Total Solar Irradiance (TSI), providing a long-term record of solar variability. The Digital Absolute Radiometer (DARA), onboard the Chinese Fengyun-3E (FY3E) spacecraft since 4 July 2021, contributes to extending this record. In this study, we [...] Read more.
Since the late 1970s, satellite missions have monitored Total Solar Irradiance (TSI), providing a long-term record of solar variability. The Digital Absolute Radiometer (DARA), onboard the Chinese Fengyun-3E (FY3E) spacecraft since 4 July 2021, contributes to extending this record. In this study, we evaluate the DARA observations in both World Radiometric Reference (WRR) and International System of Units (SI) scales. We compare these records with those from other instruments on different spacecraft (i.e., VIRGO/PMO6, TSIS-1/TIM) and with the co-located Solar Irradiance Absolute Radiometer (SIAR) on FY3E. A key finding is the identification and correction of an instrumental artifact: an issue in the thermal aperture model, linked to annual satellite maneuvers, repetitively introduced an artificial step of 0.15 ± 0.05 Wm−2 into the TSI measurements. A statistical analysis of the measurements in the SI scale shows that the mean value of the DARA TSI observations is approximately 1359.58 Wm−2 (6-hourly rate), which is lower than the ones recorded by VIRGO/PMO6 (1.82 Wm−2), TSIS-1/TIM (2.90 Wm−2), and SIAR (2.54 Wm−2). We estimate a degradation of ∼49 ppm over 46 months due to the exposure of the instrument to the (Extreme) Ultraviolet (UV/EUV) radiations. Finally, the corrected DARA observations are incorporated into the long-term TSI composite time series. Comparison with the PMOD/WRC composite shows only marginal differences (less than 0.015 Wm−2), confirming the consistency and reliability of including the new TSI product (i.e., JTSIM-DARAv1). Full article
(This article belongs to the Section Satellite Missions for Earth and Planetary Exploration)
Show Figures

Figure 1

9 pages, 854 KB  
Article
Traceability in Data Spaces: From Individual Measurements to a Digital Product Passport
by Sascha Eichstädt and Jens Niederhausen
Metrology 2025, 5(4), 70; https://doi.org/10.3390/metrology5040070 - 18 Nov 2025
Viewed by 1522
Abstract
Data spaces are digital realms of data and information shared between stakeholders and peer groups. They underpin several developments in sectors ranging from the automotive industry, through social sciences, to governmental networks. Digital traceability of information in data spaces is needed to validate [...] Read more.
Data spaces are digital realms of data and information shared between stakeholders and peer groups. They underpin several developments in sectors ranging from the automotive industry, through social sciences, to governmental networks. Digital traceability of information in data spaces is needed to validate statements about metadata, data quality, and data features. In many cases, this also directly translates to metrological traceability of measurements to the SI. The concept and development of Digital Product Passports bring these traceability aspects together to form a tool for a digital quality infrastructure. This paper outlines the general principles of digital metrological traceability based on digital certificates, a digital international system of units, and Digital Product Passports. Full article
(This article belongs to the Special Issue Metrological Traceability)
Show Figures

Figure 1

18 pages, 5781 KB  
Article
Effect of Various Factors on the Accuracy of Determining the Planck Constant in a Student Physics Laboratory
by Stanisław A. Różański
Physics 2025, 7(3), 37; https://doi.org/10.3390/physics7030037 - 15 Aug 2025
Viewed by 4165
Abstract
The Planck constant is a fundamental parameter of nature that appears in the description of phenomena on a microscopic scale. Its origin is associated with an explanation of the distribution of the blackbody spectrum performed by Max Planck. This constant stands the basis [...] Read more.
The Planck constant is a fundamental parameter of nature that appears in the description of phenomena on a microscopic scale. Its origin is associated with an explanation of the distribution of the blackbody spectrum performed by Max Planck. This constant stands the basis for the definition of the International System of Units (SI), and, in particular, the new mass definition. This paper presents different methods for determining the Planck constant based on phenomena such as blackbody radiation, light diffraction through a single slit, the current–voltage characteristics of a light-emitting diode, the photoelectric phenomenon, and the hydrogen atom spectrum in the visible range. The Planck constant was measured using instruments in a stationary laboratory and via remote access. The influence of various factors on the accuracy of the measurements was determined, and the consistency of the obtained results with the accepted value of the Planck constant are examined and discussed. Full article
(This article belongs to the Section Physics Education)
Show Figures

Figure 1

17 pages, 6103 KB  
Article
Development of Certified Reference Material of L-Thyroxine by Using Mass Balance and Quantitative Nuclear Magnetic Resonance
by Qiang Zhao, Weifei Zhang, Dan Song, Xirui Zhou, Xianjiang Li, Huan Yao, Wenjing Xing, Hongmei Li, Jian Ma and Peng Xiao
Molecules 2025, 30(13), 2840; https://doi.org/10.3390/molecules30132840 - 2 Jul 2025
Cited by 1 | Viewed by 1526
Abstract
L-thyroxine (T4) is an important hormone for diagnosing and evaluating thyroid function disorders. As outlined in ISO17511, having a certified reference material (CRM) is crucial for ensuring that the results of clinical tests are traceable to the SI-unit. This study employed two principal [...] Read more.
L-thyroxine (T4) is an important hormone for diagnosing and evaluating thyroid function disorders. As outlined in ISO17511, having a certified reference material (CRM) is crucial for ensuring that the results of clinical tests are traceable to the SI-unit. This study employed two principal methods to evaluate the purity of T4, mass balance (MB) and quantitative nuclear magnetic resonance (qNMR), both of which are SI-traceable (International System of Units) approaches. The MB method involved a detailed analysis of impurities, including water, structurally related compounds, and volatile and non-volatile substances. A variety of techniques were employed to characterize T4 and its impurities, including liquid-phase tandem high-resolution mass spectrometry, ultraviolet spectrophotometry, infrared spectroscopy, and both 1H-NMR and 13C-NMR. Additionally, impurities were quantified using Karl Fischer coulometric titration, ion chromatography, gas chromatography–mass spectrometry, and inductively coupled plasma–mass spectrometry. In qNMR, ethylparaben was used as the internal standard for direct value assignment. The results showed T4 purities of 94.92% and 94.88% for the MB and qNMR methods, respectively. The water content was determined to be 3.563% (n = 6), representing the highest impurity content. Ten structurally related organic impurities were successfully separated, and five of them were quantified. Ultimately, a purity of 94.90% was assigned to T4 CRM, with an expanded uncertainty of 0.34% (k = 2). Full article
Show Figures

Figure 1

15 pages, 1729 KB  
Article
Theory of Quantity Value Traceability of Effective Apparent Power and Evaluation Method of Uncertainty
by Yi Luo, Jingfeng Yang, Fusheng Li, Bin Qian and Xiangyong Feng
Energies 2025, 18(12), 3214; https://doi.org/10.3390/en18123214 - 19 Jun 2025
Viewed by 865
Abstract
Apparent power and power factor are crucial metrics for evaluating the energy transmission efficiency and reactive power management in power systems. The increasing complexity of power load structures, driven by evolving energy production and consumption models, has intensified the nonlinear and unbalanced characteristics [...] Read more.
Apparent power and power factor are crucial metrics for evaluating the energy transmission efficiency and reactive power management in power systems. The increasing complexity of power load structures, driven by evolving energy production and consumption models, has intensified the nonlinear and unbalanced characteristics of circuits, presenting significant challenges to accurate apparent power measurement. The IEEE 1459-2010 standard introduces the concept of effective apparent power to enhance the assessment of energy transmission efficiency under non-sinusoidal and unbalanced conditions. However, the absence of a physical standard and a standardized traceability method for effective apparent power results in inconsistent measurement outcomes across instruments. This study proposes a novel method to trace effective apparent power measurements to the International System of Units (SI) benchmarks, based on the loss characteristics of transmission lines. The method includes a comprehensive analysis of measurement uncertainty. Simulation and experimental validation confirm that the proposed traceability circuit can achieve a measurement uncertainty of 0.0110% (coverage factor k = 2), satisfying the engineering requirement of expanded uncertainty U approximately 0.02% (k = 2). These results demonstrate the method’s practical suitability for engineering applications. Full article
Show Figures

Figure 1

26 pages, 1514 KB  
Review
Challenges and Insights in Absolute Quantification of Recombinant Therapeutic Antibodies by Mass Spectrometry: An Introductory Review
by Sarah Döring, Michael G. Weller, Yvonne Reinders, Zoltán Konthur and Carsten Jaeger
Antibodies 2025, 14(1), 3; https://doi.org/10.3390/antib14010003 - 7 Jan 2025
Cited by 8 | Viewed by 7651
Abstract
This review describes mass spectrometry (MS)-based approaches for the absolute quantification of therapeutic monoclonal antibodies (mAbs), focusing on technical challenges in sample treatment and calibration. Therapeutic mAbs are crucial for treating cancer and inflammatory, infectious, and autoimmune diseases. We trace their development from [...] Read more.
This review describes mass spectrometry (MS)-based approaches for the absolute quantification of therapeutic monoclonal antibodies (mAbs), focusing on technical challenges in sample treatment and calibration. Therapeutic mAbs are crucial for treating cancer and inflammatory, infectious, and autoimmune diseases. We trace their development from hybridoma technology and the first murine mAbs in 1975 to today’s chimeric and fully human mAbs. With increasing commercial relevance, the absolute quantification of mAbs, traceable to an international standard system of units (SI units), has attracted attention from science, industry, and national metrology institutes (NMIs). Quantification of proteotypic peptides after enzymatic digestion using high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) has emerged as the most viable strategy, though methods targeting intact mAbs are still being explored. We review peptide-based quantification, focusing on critical experimental steps like denaturation, reduction, alkylation, choice of digestion enzyme, and selection of signature peptides. Challenges in amino acid analysis (AAA) for quantifying pure mAbs and peptide calibrators, along with software tools for targeted MS data analysis, are also discussed. Short explanations within each chapter provide newcomers with an overview of the field’s challenges. We conclude that, despite recent progress, further efforts are needed to overcome the many technical hurdles along the quantification workflow and discuss the prospects of developing standardized protocols and certified reference materials (CRMs) for this goal. We also suggest future applications of newer technologies for absolute mAb quantification. Full article
Show Figures

Figure 1

14 pages, 1844 KB  
Review
Avogadro and Planck Constants, Two Pillars of the International System of Units
by Enrico Massa
Physics 2024, 6(2), 845-858; https://doi.org/10.3390/physics6020052 - 3 Jun 2024
Cited by 3 | Viewed by 5265
Abstract
The International System of Units (SI), the current form of the metric system and the world’s most used system of units, has been continuously updated and refined since the Metre Convention of 1875 to ensure that it remains up to date with the [...] Read more.
The International System of Units (SI), the current form of the metric system and the world’s most used system of units, has been continuously updated and refined since the Metre Convention of 1875 to ensure that it remains up to date with the latest scientific and technological advances. The General Conference on Weights and Measures, at its 26th meeting in 2018, decided to adopt stipulated values of seven physical constants linked to seven measurement units (the second, meter, kilogram, ampere, kelvin, mole, and candela). This paper reviews the technologies developed, in intense and long-standing work, to determine the Avogadro and Planck constants, which are now integral to realising the kilogram. Full article
(This article belongs to the Special Issue Precision Physics and Fundamental Physical Constants (FFK 2023))
Show Figures

Figure 1

14 pages, 2677 KB  
Article
A 6 Mbps 7 pJ/bit CMOS Integrated Wireless Simultaneous Lightwave Information and Power Transfer System for Biomedical Implants
by Andrea De Marcellis, Guido Di Patrizio Stanchieri, Marco Faccio, Elia Palange and Timothy G. Constandinou
Electronics 2024, 13(9), 1774; https://doi.org/10.3390/electronics13091774 - 4 May 2024
Cited by 6 | Viewed by 2513
Abstract
This paper presents a Simultaneous Lightwave Information and Power Transfer (SLIPT) system for implantable biomedical applications composed of an external and internal (i.e., implantable) unit designed at a transistor level in TMSC 0.18 µm standard CMOS Si technology, requiring Si areas of 200 [...] Read more.
This paper presents a Simultaneous Lightwave Information and Power Transfer (SLIPT) system for implantable biomedical applications composed of an external and internal (i.e., implantable) unit designed at a transistor level in TMSC 0.18 µm standard CMOS Si technology, requiring Si areas of 200 × 260 µm2 and 615 × 950 µm2, respectively. The SLIPT external unit employs a semiconductor laser to transmit data and power to the SLIPT internal unit, which contains an Optical Wireless Power Transfer (OWPT) module to supply its circuitry and, in particular, the data receiver module. To enable these operations, the transmitter module of the SLIPT external unit uses a novel reverse multilevel synchronized pulse position modulation technique based on dropping the laser driving current to zero so it produces laser pulses with a reversed intensity profile. This modulation technique allows: (i) the SLIPT external unit to code and transmit data packages of 6-bit symbols received and decoded by the SLIPT internal unit; and (ii) to supply the OWPT module also in the period between the transmission of two consecutive data packages. The receiver module operates for a time window of 12.5 µs every 500 µs, this being the time needed for the OWPT module to fully recover the energy to power the SLIPT internal unit. Post-layout simulations demonstrate that the proposed SLIPT system provides a final data throughput of 6 Mbps, an energy efficiency of 7 pJ/bit, and an OWPT module power transfer efficiency of 40%. Full article
Show Figures

Figure 1

15 pages, 1415 KB  
Article
Purity Assessment of Tripropyl Phosphate through Mass Balance and 1H and 31P Quantitative Nuclear Magnetic Resonance
by Yuebing Wan, Kangcong Li, Xiuqin Li, Xiaomin Li, Hongtao Chu and Qinghe Zhang
Molecules 2024, 29(9), 1975; https://doi.org/10.3390/molecules29091975 - 25 Apr 2024
Cited by 4 | Viewed by 2160
Abstract
Tripropyl phosphate (TnPP) is a commonly used organic phosphate flame retardant in the textiles, plastics, and coating industries. Residues are commonly detected in samples from the environment and food. The availability of certified reference materials (CRMs) is essential to ensure the accuracy and [...] Read more.
Tripropyl phosphate (TnPP) is a commonly used organic phosphate flame retardant in the textiles, plastics, and coating industries. Residues are commonly detected in samples from the environment and food. The availability of certified reference materials (CRMs) is essential to ensure the accuracy and traceability of detection results. In this study, a comprehensive characterization of a CRM for TnPP was carried out, and its purity was evaluated using two distinct methodologies: mass balance (MB) and quantitative nuclear magnetic resonance spectroscopy (qNMR). In the MB method, the levels of structurally related organic impurities are 1.37 mg/g. The water content was determined to be 3.16 mg/g, while inorganic impurities were found to be 0.87 mg/g, and no residual organic solvents were detected. Benzoic acid and monocrotophos were chosen as internal standards for 1H-qNMR and 31P-qNMR, respectively. The purity of the TnPP CRM was assessed as 994.6 mg/g, 994.1 mg/g, and 993.5 mg/g using MB, 1H-qNMR, and 31P-qNMR techniques, respectively. The verified purity of the TnPP CRM was ultimately determined to be 994.1 mg/g, with an expanded uncertainty of 3.4 mg/g (k = 2), ensuring traceability to the International System of Units (SI). This CRM can be effectively utilized for preparing calibration solutions suitable for the routine monitoring of TnPP residues in plastics and food samples. Full article
(This article belongs to the Section Analytical Chemistry)
Show Figures

Figure 1

14 pages, 851 KB  
Article
Sustainability in Internal Medicine: A Year-Long Ward-Wide Observational Study
by Giuseppe A. Ramirez, Sarah Damanti, Pier Francesco Caruso, Francesca Mette, Gaia Pagliula, Adriana Cariddi, Silvia Sartorelli, Elisabetta Falbo, Raffaella Scotti, Gaetano Di Terlizzi, Lorenzo Dagna, Luisa Praderio, Maria Grazia Sabbadini, Enrica P. Bozzolo and Moreno Tresoldi
J. Pers. Med. 2024, 14(1), 115; https://doi.org/10.3390/jpm14010115 - 20 Jan 2024
Cited by 2 | Viewed by 2454
Abstract
Population aging and multimorbidity challenge health system sustainability, but the role of assistance-related variables rather than individual pathophysiological factors in determining patient outcomes is unclear. To identify assistance-related determinants of sustainable hospital healthcare, all patients hospitalised in an Internal Medicine Unit (n = [...] Read more.
Population aging and multimorbidity challenge health system sustainability, but the role of assistance-related variables rather than individual pathophysiological factors in determining patient outcomes is unclear. To identify assistance-related determinants of sustainable hospital healthcare, all patients hospitalised in an Internal Medicine Unit (n = 1073) were enrolled in a prospective year-long observational study and split 2:1 into a training (n = 726) and a validation subset (n = 347). Demographics, comorbidities, provenance setting, estimates of complexity (cumulative illness rating scale, CIRS: total, comorbidity, CIRS-CI, and severity, CIRS-SI subscores) and intensity of care (nine equivalents of manpower score, NEMS) were analysed at individual and Unit levels along with variations in healthcare personnel as determinants of in-hospital mortality, length of stay and nosocomial infections. Advanced age, higher CIRS-SI, end-stage cancer, and the absence of immune-mediated diseases were correlated with higher mortality. Admission from nursing homes or intensive care units, dependency on activity of daily living, community- or hospital-acquired infections, oxygen support and the number of exits from the Unit along with patient/physician ratios were associated with prolonged hospitalisations. Upper gastrointestinal tract disorders, advanced age and higher CIRS-SI were associated with nosocomial infections. In addition to demographic variables and multimorbidity, physician number and assistance context affect hospitalisation outcomes and healthcare sustainability. Full article
(This article belongs to the Section Epidemiology)
Show Figures

Figure 1

19 pages, 7899 KB  
Article
Intercomparison of Landsat OLI and JPSS VIIRS Using a Combination of RadCalNet Sites as a Common Reference
by Mohammad H. Tahersima, Kurtis Thome, Brian N. Wenny, Norvik Voskanian and Mehran Yarahmadi
Remote Sens. 2023, 15(23), 5562; https://doi.org/10.3390/rs15235562 - 29 Nov 2023
Cited by 5 | Viewed by 2245
Abstract
Independent radiometric data collected from multiple ground sites as part of vicarious calibration activities can be combined to harmonize the data products of Earth observation sensors with different temporal, spectral, and spatial resolutions. Recent coordinated international efforts for open fiducial reference measurements have [...] Read more.
Independent radiometric data collected from multiple ground sites as part of vicarious calibration activities can be combined to harmonize the data products of Earth observation sensors with different temporal, spectral, and spatial resolutions. Recent coordinated international efforts for open fiducial reference measurements have provided the worldwide user community with new ways to explore the calibration and harmonization of data produced by the sensors. To be correct, the results from each ground system must be traceable to the same well-understood standard system, and ideally to the international system of units (SI). Additionally, the calibration test site should be homogeneous over an area larger than the spatial resolutions of each sensor, so that ground measurements are representative of the area seen by the sensors being calibrated. Here, we use a combination of independent and SI-traceable radiometric data provided from two sites of the Radiometric Calibration Network (RadCalNet) to compare the radiometric response of sensors with different spectral and spatial resolutions that operate on different orbits. These sensors are Operational Land Imagers (OLI) of the Landsat-8 and Landsat-9 missions, and Visible Infrared Imaging Radiometer Suites (VIIRS) of the Suomi-National Polar-Orbiting Operational Environmental Satellite System Preparatory Project (SNPP) and Joint Polar Satellite System-1 (JPSS-1) missions. The sensor radiometric responses are compared via temporal averaging of the ratios of top-of-atmosphere reflectance values for each sensor to those reported by RadCalNet. Our intercomparison results show that these on-orbit sensors are calibrated within their absolute radiometric uncertainties. The absolute radiometric uncertainties of single-sensor over single-site intercomparisons at 550 nm is between 5% and 6%. Having the opportunity to look at the intercomparison results of Landsat-9 OLI compared to each calibration site individually and then in combination allowed us to investigate potential systematic site-dependent biases. We did not observe significant site-dependent biases in the behavior of the four on-orbit sensors compared to the calibration sites. The absolute radiometric uncertainty of a single sensor over multiple-site intercomparisons at 550 nm is 5.4%. We further investigated site-dependent biases by looking at the double-ratio calibration coefficients of the on-orbit sensors, calculated with reference to those sites. Full article
(This article belongs to the Special Issue Initial Understanding of Landsat-9 Capabilities and Applications)
Show Figures

Graphical abstract

Back to TopTop