Abstract
(1) Maintaining an appropriate level of cognitive workload (CWL) is crucial for work safety and efficiency. The purpose of this study is to investigate a CWL measurement method that is adaptive to changes in work situations, can be performed without interruption of primary work tasks, and is more practical than existing methods such as questionnaires. (2) We thus used the irrelevant probe technique to observe P300 amplitude, using natural sounds as the probe stimulus. Because a degradation of response sensitivity can be expected due to the presence of natural sounds that are not related to work, we also investigated whether accuracy could be improved by using coherence, which accounts for the connection between EEG measurement sites. Drone operation was selected as the model of manual control for the main task, and seven participants performed the task at three levels of difficulty. During the main task, 30 auditory probe stimulations using natural sounds were applied, and the P300 amplitudes generated in response to the auditory probe stimulations were derived from Pz, Cz, and Fz. (3) A certain degree of proportional relationship was confirmed at each measurement point depending on the difficulty of the task, although there was some variance. Comparison of coherence between measurement points revealed a certain proportional relationship between changes in task difficulty. (4) These results indicate that CWL could be evaluated with relative consistency using an index such as coherence even using the irrelevant probe method, which is considered to have low sensitivity. These results suggest that it may be possible to evaluate CWL during actual work.
1. Introduction
Workload during a cognitive task may be defined as the perceived relationship between the amount of mental processing capability or resources and the amount required by the cognitive task [1,2]. The concept of cognitive workload (CWL) takes into account that task performance is influenced not only by the cognitive difficulty of the work but also by the amount of information processing necessary when making decisions during work and changes in the surrounding environment [3,4]. As CWL is deeply involved in safety and work, particularly in terms of accidents and efficiency, it has been the subject of numerous studies [3,5,6,7]. To reduce human error, it is important to maintain CWL at an appropriate level, resulting in neither overloading nor underloading [8]. Therefore, both quantitative and objective methods for evaluating CWL may be required to ensure safety and manage efficiency [9].
Currently, subjective evaluation using a questionnaire is the most common method used to ascertain CWL. The NASA Task Load Index (NASA-TLX) is in widespread use due to its simplicity and high evaluation accuracy, and because it has been used extensively in previous studies as a reference and control [1,10,11]. However, the NASA-TLX questionnaire collects subjective evaluations and is problematic in that it necessitates interruption of actual work to allow participants to fill out the questionnaire. Furthermore, in the case of sequential change in work conditions and the work situation, the questionnaire must be repeated. Therefore, it is desirable to develop a method of continuous and subjective evaluation that does not disturb the main work itself.
Accordingly, many attempts have been made to perform objective assessment using physiological information. Event-related potential (ERP) is an endogenous component that occurs depending on the brain’s response to stimulus and is increasingly being used for this purpose. An EPR method has been proposed based on the characteristics of resource allocation of information processing in the brain for cognitive tasks and also utilizing the P300 component, which has a latency of approximately 300–400 ms evoked by perceptual stimuli and has been implicated in cognitive activity [12,13,14]. While the primary task is being performed, perceptual stimuli (e.g., auditory stimuli) are given as a secondary task as a type of “probe” at that time, and P300 potentials generated by the probe stimuli are used to estimate CWL. As there is a limit to the processing resources that humans can allocate at any one time, it is thought that the more processing resources that are required for the primary task, the fewer processing resources are allocated to the secondary tasks [15,16,17]. Therefore, when auditory stimulus is given as a probe stimulus as a secondary task, more processing resources are required for the main high-CWL task. Attention to the probe stimulus decreases accordingly, with a resulting reduction in P300 amplitude [15,16]. This method monitors passive responses using probe stimulation and enable estimation of CWL without interfering with the primary task. Therefore, this method has potential for evaluation of CWL during actual work in an objective and continuous manner, without interruption.
However, in a passive response method such as this, it is difficult to pay attention to the probe stimulus; in addition, the amplitude of P300 tends to be small. Therefore, there is a problem of low sensitivity to CWL. To produce sufficient P300 amplitude, it is necessary to provide a stimulus that allocates resources to some extent. To avoid excessive probe stimulation that interferes with the primary task, some attempts have been made to use environmental sounds unrelated to work, which is a method termed the irrelevant probe technique [18,19]. Moreover, it is known that synchronization in brain waves occurs between different measurement points during a task. In such cases, coherence, which is usually employed in synchronization analysis, is used as an index [20,21]. While the irrelevant probe technique has the potential to be applied to CWL evaluation in practical operations, it has been pointed out that it has issues with stability and sensitivity. Consequently, in recent years, studies have focused on N1 and P2 [22], while studies on coherence have primarily examined background EEG waves, such as θ and β waves, at each measurement point [23,24]. Then, we considered that using coherence might enable a clearer and more stable CWL evaluation.
Therefore, the aim of this study is to investigate whether CWL can be evaluated in realistic tasks using auditory probe stimulation. We will also evaluate whether it is possible to objectively and continuously evaluate CWL for a primary task using natural sounds and consider its relationship with coherence.
2. Materials and Methods
2.1. Experimental Setting
2.1.1. Main Task and Experimental Conditions
In selecting the model task for the experiment, the main requirement was a task that resembled actual work as much as possible. In addition, it was necessary to control the difficulty level of the main task in a stepwise manner. Accordingly, we selected operation of a drone simulator, which meets these requirements and has been used in a previous study [25,26,27,28]. Tasks were undertaken using a flight simulator software (DJI Flight Simulator v1.4.1, DJI, Shenzhen, China) with a Phantom4 Pro controller (DJI, Shenzhen, China).
The difficulty level of the main task was adjusted to three conditions (low, medium, and high difficulty levels) by a combination of forward/backward movements and ascending/descending movements of the drone in the simulator (Figure 1). In Task 1, the low-difficulty task, the participant was asked to move the drone forward at a constant speed for about 2 km along a straight road, starting from a point 7 m above the road, set in VR space. This operation was repeated several times during the duration of the experiment. In Task 2, the medium-difficulty task, the participant was asked to repeat Task 1 and then return the drone to its start position by operating the drone in the reverse direction. This operation was also repeated several times during the duration of the experiment. In Task 3, the high-difficulty task, the participant was asked to operate the drone up and down within a height range of 2–7 m, in addition to the task of linear forward and backward movement as in Task 2.
Figure 1.
Screen display image and course taken by the drone for each level of difficulty in the main experimental tasks.
Since the system used for the main task in this study cannot capture performance data such as flight accuracy or changes in speed, we selected the experimental conditions by applying several conditions and conducting subjective evaluations to verify that they maintained a constant relationship—specifically, that three stepwise difficulty levels for the experimental tasks were arranged—and then configured the system accordingly. Prior to the experiment, we conducted a simple 10-point rating questionnaire to act as a reference. We asked seven participants to evaluate change in difficulty with progression of the tasks. Task 1 (lowest difficulty) was set as the base, as one point. The participants compared the difficulty of each of Task 2 and Task 3 with Task 1 as the reference, and assigned a score for each task (maximum score, 10 points). The mean scores were 3.57 ± 0.44 points for Task 2 and 7.42 ± 0.60 points for Task 3. As these results confirmed that difficulty increased proportionally according to the subjective sensation of the participants, these three tasks were selected. After allowing sufficient practice time for the participants to get used to the tasks, the experiment was conducted. Rather than a fixed number of practice trials for each task, participants were allowed to practice each task until they could perform it without errors.
2.1.2. Stimulus Sounds of the Secondary Task as Irrelevant Probe Stimulus
As the secondary task, the probe stimulation was set to 30 different familiar environmental sounds with reference to Fabiani et al. [29]. We selected animal-related sounds such as cat meowing and birdsong; human-related sounds such as laughter and coughing; sounds of musical instruments such as the xylophone, guitar, and drums; and other commonly experienced environmental noises such as the sound of dripping water and a doorbell, among others. The stimulus sounds were obtained from the Internet as freely available WAV files from general sound sources and were re-edited as monaural sound sources. The stimulation frequency was set as 30 times with stimulation duration of 300 ms and stimulation interval of 6–30 s. The participants received the stimulus sounds adjusted to about 70 dB via earphones [29] and presented at random. Sound pressure was measured using a digital sound level meter (TM-102, TENMARS, AS ONE Corporation, Tokyo, Japan).
The trigger was generated as a square wave with a period of 600 ms with the timing synchronized with the start time of the stimulus. When presenting the stimulus, the Simulink Multiport Selector block was used.
2.2. Experimental Procedure
Seven healthy male university students (mean age, 22.29 ± 2.05 years) were selected as the volunteer subjects. The absence of any abnormality in hearing or vision (including corrected visual acuity) was confirmed in all subjects by medical checks.
Before the experiment, all subjects were provided with a detailed written explanation of the study’s objectives, methods, risks, and privacy protections, and their informed consent to participate in the study was obtained both in writing and verbally. We gave the subjects the following five instructions: (1) reduce movements, such as blinking and eye movement, as much as possible, except those related to the experiment; (2) ignore the secondary stimulus of the probe stimulation; (3) try to look only at the drone; (4) keep the drone within the width of the road that can be seen directly below; and (5) pilot with accuracy rather than speed in mind.
Each subject was equipped with an electroencephalograph (EEG) and earphones and was seated 1 m in front of the 15.6-inch task PC. Participants were positioned with their head resting on a chin stand to suppress body movement, and body grounds were attached to the left wrist and sole of the foot (Figure 2).
Figure 2.
Experimental setting. (a) Schematic diagram of the experimental devices. (b) Photo of the experiment.
Before the start of the experiment, measurements were obtained with each participant listening only to the probe stimulus in the passive condition, as the control (hereafter “control task”). At this time, the participant gazed at a point on the wall about 2 m ahead instead of at the PC. The three tasks (low, medium, and high difficulty) were then conducted for 7 min each in random order. After completing one task, the participants rested for 10 min before beginning the next task. The length of the break was determined by considering both the need to reduce participant fatigue and the experimenters’ logistical needs regarding preparation and setup for the next task. Since the break was longer than the trial period for each task, it was considered sufficient; therefore, we did not specifically address the control of fatigue in this study. During the tasks, irrelevant auditory stimuli lasting 300 ms were presented in random order, with a stimulus interval ranging from 6 to 30 s, averaging 12 s.
At the end of each task, the participant completed the NASA-TLX questionnaire [30,31] as a subjective evaluation.
This experimental protocol was reviewed by the Kansai University Ethics Committee and conducted under their supervision by the safety management committee in Kansai University (approval no. 12-3).
2.3. Data Acquisition
EEG measurements were obtained using g.Nautilus (g.tec medical engineering GmbH, Schiedlberg, Austria). Prior to the experiment, an electrode cap (g.GAMMAcap2, g.tec medical engineering GmbH, Schiedlberg, Austria) equipped with 15 electrodes was placed on each subject’s head (g.SCARABEO; g.tec medical engineering GmbH, Schiedlberg, Austria) (Figure 2a). Fifteen electrodes were placed at Fz, Cz, Pz, FT7, FT8, T7, T8, TP7, TP8, FC3, FC4, C5, C6, CP3, CP4 according to the international 10–10 system. The reference electrode was the right earlobe (A2), and the ground electrode was AFz. Similarly to previous studies, the three points of Fz, Cz, and Pz were the main points analyzed [16,18]. The impedance of electrodes was set to 30 kΩ or less and data were recorded with a sampling frequency of 500 Hz. Although values of 10 kΩ or less are generally considered desirable for EEG testing, we set the value to 30 kΩ in this study because the likelihood of task-related noise and artifacts was increased compared to resting conditions. To avoid recording eye movements and blinks as artifacts, an electrooculogram (EOG) was measured from below the right eye.
Functional near-infrared spectroscopy (fNIRS) in the subject’s frontal region was also measured during this experiment as a reference. With reference to previous studies [32,33,34], we targeted the prefrontal cortex, which is known to be activated by cognitive load. The light-transmitting probes and also the receiving probes were arranged as a total of eight channels (four channels on each of the left and right frontal regions) at an interval of 32 mm and recorded at a sampling frequency of 10 Hz. However, likely due to the slower response speed of fNIRS compared to EEG, we excluded it from this report because we were unable to confirm results as clear as those obtained with EEG.
2.4. Analysis
The recorded EEG raw data were analyzed using EEGLAB (version 13.5.4, SCCN, UCSD, San Diego, CA, USA) and MATLAB (R2019b., The MathWorks Inc., Natick, MA, USA). The signal processing series was performed with reference to a previous study [35]. To remove noise, a FIR bandpass filter with −6 dB cutoff frequencies of 0.05 and 30 Hz was applied to the raw EEG data. In this study, a zero-phase, linear-phase FIR bandpass filter with a Hamming window was used to prevent time delays and phase distortion, and a 60 Hz notch filter was combined with it to remove power supply noise and the baseline.
Independent component analysis (ICA) was performed on the continuous EEG data recorded from 15 electrodes using Infomax ICA of EEGLAB prior to epoch extraction to identify and remove non-neural artifacts. The potential offset was adjusted using the baseline as the average potential for 100 ms before presentation of the stimulus. Ocular artifact-related independent components were identified based on their temporal characteristics and correspondence with the EOG signal recorded from the right eye. To verify the relationship with EOG, we used the correlation coefficient; based on the criteria from previous research, a correlation coefficient of approximately 0.4 was used as the reference, and we also visually verified the relationship. Components representing ocular artifacts were removed, and the EEG signals were reconstructed using the remaining independent components.
Using the trigger signal generated synchronously with the probe stimulus, EEG data between 100 ms before and 600 ms after the trigger signal were epoched. Epochs where it was clearly evident that artifact removal had been unsuccessful using ICA, as well as those with amplitudes of ±100 μV or greater, were manually excluded. The average number of epochs after removal was 28, with the lowest being 26.
The P300 amplitude was then calculated by signal averaging using the remaining epochs. The P300 amplitude was calculated as the average potential within 100 ms before and after the peak potential occurring 250–500 ms post-stimulus. While a relatively clear P300 response can be observed in response to a single-tone stimulus, the response as an ERP is delayed because the stimuli used in this study are natural sounds irrelevant to the task. Additionally, since latencies vary depending on the type of sound and the individual subject, this range was selected.
In order to derive coherence between Pz and Cz, Cz and Fz, and Pz and Fz for each subject, averaged ERP waveforms based on samples from 100 msec before to 600 msec after the trigger were used. The magnitude-squared coherence was calculated using the function “mscohere” included in MATLAB, and this value was used as the coherence for evaluation. Based on the settings used in previous studies, the window function was set to Hamming, the window length was approximately 150 msec, and the overlap was 50%; consequently, the frequency resolution was approximately 1.95 Hz.
In the subjective evaluation using the questionnaire, the weighted workload (WWL) score was calculated from the results of NASA-TLX, and the total scores for all subjects were compared among the three task conditions [30,31]. The WWL score was evaluated using one-way analysis of variance (ANOVA) with task difficulty as a factor. Regarding the P300 amplitudes of Pz, Cz, and Fz, two-way ANOVA was conducted with two factors (task difficulty and measurement points of EEG) with reference to previous studies [18]. Significant differences between the task conditions, the measurement sites, and interactions of the two factors were evaluated. In the case of significant differences according to ANOVA, Tukey–Kramer’s multiple comparison test was used to confirm differences in measurement points between the task conditions. As for P300, ANOVA and Tukey–Kramer’s multiple comparison test were used to investigate the relationship between coherence at each of the three measurement points and the task conditions. The relationships between the WWL score of NASA-TLX as the reference, P300 amplitudes, and coherence were analyzed by correlation analysis. These statistical processes were performed using Excel and Excel Add-in software for statistical analysis (BellCurve for Excel, version 2022, Social Survey Research Information Co., Ltd., Tokyo, Japan).
3. Results
3.1. Subjective Evaluation
Figure 3 shows the WWL scores of NASA-TLX for all subjects, presented as the mean values and standard deviation. There is a trend of increasing WWL score with increasing level of difficulty. One-way ANOVA showed a gradual difference due to large individual differences (p = 0.081, F = 2.89 < F(2, 18, 0.05) = 3.55 → †). Although the trend is very weak, a certain proportional trend was observed between WWL scores and task difficulty.
Figure 3.
Results of WWL scores of NASA-TLX in all subjects for all three task conditions.
3.2. P300 Amplitude
3.2.1. Sample Data of P300 Signals
Figure 4 shows a representative ERP waveform (subject S1) after averaging the responses to each of the three tasks, with the passive condition as a control. To enable observation of P300, the EEG waveform is shown from 100 ms before stimulus presentation to 600 ms after stimulus presentation, with stimulus presentation at 0 s. The measurement position of the sample is Pz, where there was significant difference in the change in amplitude. The figure shows that a positive waveform is generated relatively steeply in the vicinity of 300 to 400 ms under any task condition. Among the conditions, the passive condition (control) showed the highest amplitude at 300–400 ms. Moreover, the potential at around 300 to 400 ms showed decreasing trends from Tasks 1 to 3 as the difficulty level increased. Individual differences were also confirmed; however, the same tendency was confirmed in each subject.
Figure 4.
Sample signals of P300 for four task conditions measured at Pz (in Subject 1).
3.2.2. P300 Signals in All Subjects
Figure 5 shows the results of P300 amplitude at Pz, Cz, and Fz for each task in all subjects; although there was some variation, a certain trend remains between tasks at all three measurement points. A tendency of decreasing P300 amplitude with increasing difficulty level was confirmed at each measurement point. It is noteworthy that there is almost no difference between Tasks 2 and 3 in Pz, and variance is large and unstable at all measurement points.
Figure 5.
Comparison between the P300 amplitudes of all subjects in three task conditions (*: p < 0.05, **: p < 0.01, †: p < 0.10).
A two-way ANOVA with replication was performed for P300 amplitude at each measurement point with two factors: conditions and measurement points. The task condition consisted of a passive condition as a control and three conditions with varying levels of difficulty, for a total of four levels. The measurement points were Pz, Cz, and Fz, each with three levels. The analysis was conducted using data from seven participants.
The results showed a significant difference between each experimental condition (p = 0.042, F = 2.882 > F(3, 72, 0.05) = 2.732 → *); whereas there was no significant difference between the measurement points (p = 0.491, F = 0.719 < F(2, 72, 0.05) = 3.124 → n.s.) and no significant difference in interaction between the two factors: task conditions and measurement points (p = 0.998, F = 0.075 < F(6, 72, 0.05) = 2.223 → n.s.).
Table 1 summarizes the results of p-values calculated using Tukey–Kramer’s multiple comparison test, performed to confirm significant differences between each condition in the measurement points. Although the differences between Task 1 and Task 2 and between Task 1 and Task 3 (excluding Fz) were modest, a certain degree of statistical significance was observed; however, no significant difference was observed between Task 2 and Task 3. Furthermore, while a clear statistical difference was observed between the control and Tasks 2 and 3, no significant difference was found between the control and Task 1.
Table 1.
The results of p-values analyzed using Tukey–Kramer’s multiple comparison test, confirming differences between each task condition at various measurement points (*: p < 0.05, **: p < 0.01, †: p < 0.10).
3.2.3. Coherence
Figure 6 presents the coherence values between measurement points based on the P300 amplitudes at Pz, Cz, and Fz in each task condition in all subjects. Although the differences between tasks are small and the variance is relatively large, it was observed that the coherence tended to increase at each measurement point as the difficulty of the task increased. However, in contrast, ANOVA performed in the same manner as described above identified no significant difference between the measurement positions; i.e., between Pz-Cz, Cz-Fz, or Pz-Fz (p = 0.366, F = 1.018 < F(2, 72, 0.05) = 3.124 → n.s.) or between the tasks (p = 0.353, F = 1.103 < F(3, 72, 0.05) = 2.732 → n.s.). Moreover, there was no interaction between factors (p = 0.995, F = 0.112 < F(6,72, 0.05) = 2.223 → n.s.). Tukey–Kramer’s multiple comparison test was also performed as for the P300 amplitudes described above, but as the values were small, no clear significant difference in coherence was observed between any measurement points.
Figure 6.
Comparison of results of coherence based on P300 amplitudes of all subjects in three task conditions.
3.2.4. Relationships Between NASA-TLX and Evaluation Parameters of EEG
Figure 7 shows the relationship between the WWL score of NASA-TLX as the reference and both P300 (Figure 7a) and coherence (Figure 7b). Because there is significant individual variation, it is difficult to identify a relationship clearly even by analyzing the data as a whole. Therefore, we decided to use the mean values for each participant to confirm general trends. The NASA-TLX and P300 (Pz: r = −0.793, Cz: r = −0.954, Fz: r = −0.996) and the NASA-TLX and coherence (Pz-Cz: r = 0.990, Cz-Fz: r = 0.964, Pz-Fz: r = 0.971) showed certain correlations. Similarly, repeated-measures correlation analysis was also conducted to examine the relationship between the NASA-TLX and P300, as well as between the NASA-TLX and each measurement point. Regarding the relationship between the NASA-TLX and P300, the correlation coefficients were low at all measurement points, and no significant relationship was found (Pz: r = −0.339, p-value = 0.257, Cz: −0.481, p-value = 0.096, Fz: r = −0.421, p-value = 0.152). On the other hand, regarding the coherence between the NASA-TLX and each measurement point, a weak relationship was observed the coherence between Pz and Cz (Pz-Cz: r = 0.653, p-value = 0.008, Cz-Fz: r = 0.526, p-value = 0.065, Pz-Fz: r = 0.489, p-value = 0.089).
Figure 7.
Comparison between results of coherence based on P300 amplitudes of all subjects in three task conditions. (a) Relation between WWL score of NASA-TLX as reference and P300 at each measurement point. (b) Relation between WWL score of NASA-TLX as reference and coherence between the measurement points.
4. Discussion
4.1. Subjective Evaluation
Prior to examining CWL, which was the purpose of this study, it was necessary to design a suitable controlled task. The task needed to satisfy the following requirements: manually controlled, presented to resemble realistic tasks rather than simple stimuli (such as experiments performed in a laboratory), and with an incremental change in difficulty level. However, since this system does not allow for the collection of detailed performance data, we had participants conduct various tasks during a preliminary survey. We adjusted the difficulty level by increasing the number of procedural steps and had them conduct various tasks, before selecting three types of tasks. Although the NASA-TLX cannot express effectiveness and is therefore insufficient as a usability evaluation, we used it solely for an alternative reference value.
Despite the presence of individual differences, the results of the NASA-TLX WWL scores in Figure 3 show that the difficulty level could be increased incrementally by adding operational elements based on Task 1. Therefore, we considered the three types of tasks to be appropriate for use as difficulty settings. In addition, we considered that WWL score could be used as a reference for CWL.
4.2. P300 Amplitude
We confirmed the presence of P300 signals (Figure 4); however, due to significant individual differences and variability, we were unable to clearly confirm a statistically significant relationship between P300 amplitude and task difficulty. However, the results (Figure 5) suggest that it may be possible to distinguish to some extent between the passive control condition and the higher-load task condition. Similarly, we confirmed that as a secondary task, the auditory probes functioned to some extent as expected. Previous studies have reported that an increase in task difficulty increases CWL when performing the main task, which then necessitates an increased allocation of resources to cognitive tasks. Accordingly, fewer resources are allocated to probe stimulation as the secondary task [19].
Although no significant difference was observed between the control and Task 1 which is low difficulty, statistically significant differences were observed to some extent at each measurement point between the control and Tasks 2 and 3 (Table 1). On the other hand, for comparisons between the tasks themselves, the results varied—with some measurement points showing statistically significant differences and others not—and no consistent trend could be identified. In a previous study that used natural sounds as stimuli, the change in P300 was small (several microvolts) but a statistically significant difference was confirmed [19], which was thought to be due primarily to large variance. Similarly, it is likely that the large variance in the present study influenced our results, and was probably caused by artifacts such as body movement, the number of stimuli, and also analytical problems such as averaging an insufficient number of stimuli. In particular, with regard to artifact removal, various methods suitable for more effective real-time processing have been proposed in recent years [36,37]; therefore, it is considered necessary to examine the applicability of these processing methods. At the same time, we believe that individual differences had a significant impact due to the small number of participants in this study. Interviews conducted after the experiment regarding each subject’s impressions also suggested that the degree of proficiency and how they perceived the degree of difficulty were involved in the variance in results. Similarly to the observations of previous studies [18,19], we believe that there remains a problem in detection sensitivity in practical use.
Because the coherence values between all measurement points were themselves small and the variances were relatively large compared to the coherence values, the significant differences in coherence among the measurement points could not be confirmed by Tukey–Kramer’s multiple comparison test. Compared to the results of P300 alone (Figure 5) with the result based on coherence (Figure 6), it can be seen that the trend of change appears to follow a relatively stable proportional relationship. Although the sample size is small, the comparison is based on mean values, and the variance is relatively large compared to the mean, a linear trend can be observed in the coherence of Pz and Cz—which were particularly unstable when considered alone. These results suggest that it may be possible to eliminate, to some extent, the variability and instability caused by fluctuations in P300 amplitudes and differences in measurement points.
Regarding the relationship between task conditions (i.e., task difficulty) and coherence across measurement points, as task difficulty increased, the amplitude of the P300 at Pz became more unstable, accompanied by a slight decrease in the correlation coefficient (Figure 7a). However, the results of the repeated-measures correlation analysis showed that it was difficult to identify a consistent relationship at each measurement point. On the other hand, regarding coherence at each measurement point, in contrast to the results based on P300 amplitude, a trend of increasing tendency was observed as task difficulty increased (Figure 7b). Although the results of the repeated-measures correlation analysis showed a tendency for the correlation coefficients to be lower than the overall correlation coefficient—similar to the tendency observed for P300 amplitude—a certain trend, albeit a slight one, was confirmed, particularly between Pz and Cz.
As coherence is an index that indicates the strength of connections between measurement points, and the brain controls higher functions via a network, it is therefore thought that the results of coherence may be able to indicate connections in a relatively stable manner compared with observation at fixed points. Indeed, previous studies have reported the efficacy of coherence applied to medical diagnosis [38], psychiatry [39], and even a brain–computer interface [40]. For these reasons, coherence was used in this study, and the results suggest that P300 coherence—as a response to probe stimuli of irrelevant natural sound—may be applicable for evaluating CWL.
On the other hand, since these are simple comparisons of mean values, the results merely indicate general trends in the relationship between the two variables. In fact, as no clear significant differences in coherence were found due to its small values, further investigation is required to clarify these changes. Additionally, since the coherence calculated in this study is based on an averaged and short ERP waveform, it remains possible that it simply reflects signal similarity between adjacent scalp electrodes; therefore, caution is required in its interpretation. Nevertheless, the present results are considered important as they indicate the possibility that changes in coherence that occur in response to changes in task difficulty could be used as a stable estimate of CWL. Furthermore, an increase in coherence does not necessarily indicate enhanced functional connectivity or network integration; it may simply reflect statistical similarity among scalp signals. Since control for fatigue was not addressed in this study, the effects of fatigue and learning could not be completely ruled out, and there might be some limitations in interpreting the results. These points also require further detailed investigation.
5. Conclusions
The present experiments and analyses aimed to estimate change in CWL according to change in cognitive difficulty in a task using probe stimulation with natural sounds, and showed that P300 amplitude tended to decrease, and the coherence value between each EEG measurement point increased, when the operator perceived difficulty. Although it is necessary to deal with problems affected by task proficiency, individual differences and artifacts, our results suggest the possibility that CWL can be estimated even in realistic tasks by using auditory stimuli with natural sounds as probes. In other words, it is possible that CWL could be effectively detected when signal processing is applied to reduce noise and when there is a large difference between the difficulty levels of different tasks.
On the other hand, although this study focused specifically on men, since previous research has not indicated any gender differences, it is believed that gender would not have an impact on the results. However, given the small sample size, further research is required.
As ERP by irrelevant probe stimulation is often low in amplitude, it can be difficult to discriminate when the conditional difference is small. This difficulty could possibly be overcome by devising EEG processing methods and using indices such as coherence. Further improvement can be expected in the detection sensitivity of change in CWL with future developments. As the present method can be systematized relatively easily, it is expected to find applications in this field.
Author Contributions
Conceptualization, S.S., K.O. and H.K.; methodology, S.S., K.O. and H.K.; software, K.O. and H.K.; validation, S.S., K.O. and H.K.; formal analysis, S.S., K.O. and H.K.; investigation, K.O. and H.K.; resources, S.S., K.O. and H.K.; data curation, S.S., K.O. and H.K.; writing—original draft preparation, S.S.; writing—review and editing, S.S.; visualization, S.S.; supervision, S.S., K.K. and T.A.; project administration, S.S. All authors have read and agreed to the published version of the manuscript.
Funding
This research received no external funding.
Data Availability Statement
Data are available upon reasonable request and approved by the ethics committee of Kansai University by contacting the corresponding author.
Conflicts of Interest
The authors declare no conflict of interest.
References
- Hart, S.G.; Staveland, L.E. Development of NASA-TLX (Task Load Index): Results of Empirical and Theoretical Research. In Advances in Psychology; Hancock, P.A., Meshkati, N., Eds.; North-Holland: Amsterdam, The Netherlands, 1988; Volume 52, pp. 139–183. [Google Scholar]
- Jacobs, K.; Hellman, M.; Markowitz, J.; Wuest, E. Workload. In Encyclopedia of Behavioral Medicine; Gellman, M.D., Turner, J.R., Eds.; Springer: New York, NY, USA, 2013. [Google Scholar]
- Patten, C.J.D.; Kircher, A.; Östlund, J.; Nilsson, L.; Svenson, O. Driver experience and cognitive workload in different traffic environments. Accid. Anal. Prev. 2006, 38, 887–894. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Ghani, U.; Signal, N.; Niazi, I.K.; Taylor, D. ERP based measures of cognitive workload: A review. Neurosci. Biobehav. Rev. 2020, 118, 18–26. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Strayer, D.L.; Watson, J.M.; Drews, F.A. Cognitive Distraction While Multitasking in the Automobile. Psychol. Learn. Motiv. 2011, 54, 29–58. [Google Scholar] [CrossRef] [Scilit]
- Gentili, R.J.; Rietschel, J.C.; Jaquess, K.J.; Lo, L.C.; Prevost, C.M.; Miller, M.W.; Mohler, J.M.; Oh, H.; Tan, Y.Y.; Hatfield, B.D. Brain biomarkers based assessment of cognitive workload in pilots under various task demands. In Proceedings of the 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Chicago, IL, USA, 26–30 August 2014; pp. 5860–5863. [Google Scholar]
- Wilbanks, B.A.; McMullan, S.P. A Review of Measuring the Cognitive Workload of Electronic Health Records. Comput Inf. Nurs. 2018, 36, 579–588. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Chin, Z.Y.; Zhang, X.; Wang, C.; Ang, K.K. EEG-based discrimination of different cognitive workload levels from mental arithmetic. In Proceedings of the 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Honolulu, HI, USA, 17–21 July 2018; pp. 1984–1987. [Google Scholar]
- Wickens, C.D. Processing resources in attention. In Varieties of Attention; Parasuraman, R., Davies, D.R., Eds.; Academic Press: New York, NY, USA, 1984; pp. 63–102. [Google Scholar]
- Cheng, S.Y. Evaluation of Effect on Cognition Response to Time Pressure by Using EEG. In Advances in Human Factors and Ergonomics in Healthcare and Medical Devices (AHFE 2017); Duffy, V., Lightner, N., Eds.; Springer: Berlin/Heidelberg, Germany, 2018; pp. 45–52. [Google Scholar]
- Huggins, A.; Claudio, D. A performance comparison between the subjective workload analysis technique and the NASA-TLX in a healthcare setting. IISE Trans. Healthc. Syst. Eng. 2018, 8, 59–71. [Google Scholar] [CrossRef] [Scilit]
- Spencer, K.M.; Polich, J. Poststimulus EEG spectral analysis and P300: Attention, task, and probability. Psychophysiology 1999, 36, 220–232. [Google Scholar] [CrossRef] [Scilit]
- Polich, J. Updating P300: An integrative theory of P3a and P3b. Clin. Neurophysiol. 2007, 118, 2128–2148. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Helfrich, R.F.; Knight, R.T. Cognitive neurophysiology: Event-related potentials. Handb. Clin. Neurol. 2019, 160, 543–558. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Kramer, A.F.; Trejo, L.J.; Humphrey, D. Assessment of mental workload with task-irrelevant auditory probes. Biol. Psychol. 1995, 40, 83–100. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Kramer, A.F.; Weber, T. Applications of psychophysiology to human factors. In Handbook of Psychophysiology, 2nd ed.; Cacioppo, J.T., Tassinary, L.G., Berntson, G.G., Eds.; Cambridge University Press: Cambridge, UK, 2000; pp. 794–814. [Google Scholar]
- Ullsperger, P.; Freude, G.; Erdmann, U. Auditory probe sensitivity to mental workload changes-An event-related potential study. Int. J. Psychophysiol. 2001, 40, 201–209. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Dyke, F.; Leiker, A.; Grand, K.; Godwin, M.M.; Thompson, A.G.; Rietschel, J.C.; McDonald, C.G.; Miller, M.W. The Efficacy of Auditory Probes in Indexing Cognitive Workload Is Dependent on Stimulus Complexity and Magnitude of Attentional Orienting. Int. J. Psychophysiol. 2015, 51, S52. [Google Scholar]
- Shaw, E.P.; Rietschel, J.C.; Hendershot, B.D.; Pruziner, A.L.; Miller, M.W.; Hatfield, B.D.; Gentili, R.J. Measurement of attentional reserve and mental effort for cognitive workload assessment under various task demands during dual-task walking. Biol. Psychol. 2018, 134, 39–51. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Nunez, P.L.; Srinivasan, R.; Westdorp, A.F.; Wijesinghe, R.S.; Tucker, D.M.; Silberstein, R.B.; Cadusch, P.J. EEG coherency I: Statistics, reference electrode, volume conduction, Laplacians, cortical imaging, and interpretation at multiple scales. Electroencephalogr. Clin. Neurophysiol. 1997, 103, 499–515. [Google Scholar] [PubMed]
- Nunez, P.L.; Srinivasan, R. Electric Fields of the Brain: The Neurophysics of EEG, 2nd ed.; Oxford University Press: New York, NY, USA, 2006. [Google Scholar]
- Fuseda, K.; Kimura, M.; Sugimoto, F.; Takeda, Y.; Onuki, M.; Akamatsu, M.; Kihara, K. Evaluating changes in proficiency using the task-irrelevant probe technique with event-related brain potentials. Biol. Psychol. 2026, 204, 109200. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Liu, R.; Qi, S.; Hao, S.; Lian, G.; Luo, Y. Using electroencephalography to analyse drivers’ different cognitive workload characteristics based on on-road experiment. Front Psychol. 2023, 14, 1107176. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Kamzanova, A.; Matthews, G.; Kustubayeva, A. EEG Coherence Metrics for Vigilance: Sensitivity to Workload, Time-on-Task, and Individual Differences. Appl. Psychophysiol. Biofeedback 2020, 45, 183–194. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Dell’Agnola, F.; Cammoun, L.; Atienza, D. Physiological characterization of need for assistance in rescue missions with drones. In Proceedings of the 2018 IEEE International Conference on Consumer Electronics (ICCE), Las Vegas, NV, USA, 12–14 January 2018; pp. 1–6. [Google Scholar]
- Dell’Agnola, F.; Momeni, N.; Arza, A.; Atienza, D. Cognitive workload monitoring in virtual reality based rescue missions with drones. In Proceedings of the 12th International Conference on Virtual, Augmented and Mixed Reality (VAMR 2020), Copenhagen, Denmark, 19–24 July 2020; pp. 397–409. [Google Scholar]
- Mohanavelu, K.; Poonguzhali, S.; Ravi, D.; Singh, P.K.; Mahajabin, M.; Ramachandran, K.; Singh, U.K.; Jayaraman, S. Cognitive workload analysis of fighter aircraft pilots in flight simulator environment. Def. Sci. J. 2020, 70, 131–139. [Google Scholar] [CrossRef] [Scilit]
- Abioye, A.O.; Prior, S.D.; Saddington, P.; Ramchurn, S.D. The performance and cognitive workload analysis of a multimodal speech and visual gesture (mSVG) UAV control interface. Rob. Auton. Syst. 2022, 147, 103915. [Google Scholar] [CrossRef] [Scilit]
- Fabiani, M.; Kazmerski, V.; Cycowicz, Y.; Friedman, D. Naming norms for brief environmental sounds: Effects of age and dementia. Psychophysiology 1996, 33, 462–475. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Miyake, S.; Kumashiro, M. Subjective mental workload assessment technique -An introduction to NASA-TLX and SWAT and a proposal of simple scoring methods. Jap. J. Ergon. 1993, 29, 399–408. (In Japanese) [Google Scholar] [CrossRef] [Scilit]
- Haga, S.; Mizukami, N. Japanese version of NASA Task Load Index: Sensitivity of its workload score to difficulty of three different laboratory tasks. Jpn. J. Ergon. 1996, 32, 71–79. (In Japanese) [Google Scholar] [CrossRef] [Scilit]
- Cohen, J.D.; Perlstein, W.M.; Braver, T.S.; Nystrom, L.E.; Noll, D.C.; Jonides, J.; Smith, E.E. Temporal dynamics of brain activation during a working memory task. Nature 1997, 386, 604–608. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Rypma, B.; D’Esposito, M. The roles of prefrontal brain regions in components of working memory: Effects of memory load and individual differences. Proc. Natl. Acad. Sci. USA 1999, 96, 6558–6563. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Fishburn, F.A.; Norr, M.E.; Medvedev, A.V.; Vaidya, C.J. Sensitivity of fNIRS to cognitive state and load. Front. Hum. Neurosci. 2014, 8, 1–11. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Wang, Y.; Wang, Z.; Clifford, W.; Markham, C.; Ward, T.E.; Deegan, C. Validation of low-cost wireless EEG system for measuring event-related potentials. In Proceedings of the 2018 29th Irish Signals and Systems Conference (ISSC 2018), Belfast, UK, 21–22 June 2018; Volume 2018, pp. 1–6. [Google Scholar]
- Ronca, V.; Flumeri, G.D.; Giorgi, A.; Vozzi, A.; Capotorto, R.; Germano, D.; Sciaraffa, N.; Borghini, G.; Babiloni, F.; Aricò, P. O-CLEAN: A novel multi-stage algorithm for the ocular artifacts’ correction from EEG data in out-of-the-lab applications. J. Neural Eng. 2024, 21, 056023. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Ronca, V.; Di Flumeri, G.; Lungarini, L.; Capotorto, R.; Germano, D.; Giorgi, A.; Borghini, G.; Babiloni, F.; Arico, P. A Novel Multi-Stage Algorithm for Real-Time Detection and Correction of Ocular Artifacts in EEG: A Calibration-Free Approach. In Proceedings of the 2025 47th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC 2025), Copenhagen, Denmark, 14–18 July 2025; pp. 1–7. [Google Scholar]
- Zhang, Y.; Li, R.; Du, J.; Huo, S.; Hao, J.; Song, W. Coherence in P300 as a predictor for the recovery from disorders of consciousness. Neurosci. Lett. 2017, 653, 332–336. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Takano, K.; Ora, H.; Sekihara, K.; Iwaki, S.; Kansaku, K. Coherent activity in bilateral parieto-occipital cortices during P300-BCI operation. Front. Neurol. 2014, 5, 74. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Gentsch, K.; Grandjean, D.; Scherer, K.R. Coherence explored between emotion components: Evidence from event-related potentials and facial electromyography. Biol. Psychol. 2014, 98, 70–81. [Google Scholar] [CrossRef] [Scilit] [PubMed]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.






