Abstract
Lithium-ion battery safety testing is essential for understanding cell behavior under abuse conditions. However, despite recent advances in test standardization, the quantitative assessment of safety-relevant temperatures remains sensitive to thermal runaway criteria and temperature sensor positioning. To address this issue, 20 commercially available 18650-type cells of the same type were investigated by thermal stability and lateral heating tests, using multiple temperature sensor positions and thermal runaway criteria. Thermal runaway criteria based on changes in vent gas temperature were introduced, providing a robust and precise alternative for thermal runaway identification. Both safety tests revealed pronounced intra- and inter-cell variability, which posed a significant risk of misinterpreting test results. Statistical analysis revealed that increasing the number of measurement positions enabled identification of the actual temperature of safety-relevant events with significantly higher accuracy, thus reducing the required sample size.
1. Introduction
With the expanding use of lithium-ion batteries across diverse areas of daily life, understanding the impact of safety-critical incidents on battery cell behavior has become essential. To address this need, safety tests are conducted to evaluate battery cell behavior under various abuse conditions. These tests commonly follow established standards [1,2,3,4,5,6,7,8,9,10,11,12,13], which specify test procedures, setups, sample size, measurement guidelines, and criteria for identifying safety-relevant events.
During safety tests, abuse often leads to exothermic side reactions, which cause an increase in cell temperature and can ultimately lead to thermal runaway [14,15,16,17,18]. To study these effects, test standards require temperature recording during safety tests and define the required measurement accuracy and frequency. However, requirements regarding the number and positions of temperature sensors remain inconsistent across different safety tests. Although some test standards define the number and positions of sensors for specific tests [6,7,9,12], others recommend several distributed sensors [3,5] without specifying their number and positions. Given these inconsistencies, comparability between studies remains challenging.
Studies employing multiple temperature sensors on the cell surface have shown that temperature differences between sensors were likely [19,20,21,22,23,24], indicating an inhomogeneous temperature distribution over the cell surface. Temperature differences were observed both prior to thermal runaway and in the maximum temperature obtained after cells underwent thermal runaway. In addition to differences in temperature on the cell surface, inter-cell variability was shown to further contribute to differences in safety-relevant parameters [19,25,26,27,28,29], highlighting the challenge of reliably determining cell behavior, particularly for small sample sizes [29].
In addition to these intra- and inter-cell variations in temperature during safety tests, definitions of safety-relevant events, such as thermal runaway, further complicate comparability among studies. While alternative approaches like gas sensors, audio recording, and voltage drop exist [30,31,32], thermal runaway detection is predominantly based on criteria related to the cell temperature rise rate, . Some standards and publications applied different thresholds, including >1 K s−1 (60 K min−1) [4], >1.67 K s−1 (100 K min−1) [31], and >15 K s−1 (900 K min−1) [6]. Other standards, including ISO 6469-1, UNECE GTR20, GB 38031-2025, and ECE R100.05, represent important progress by combining temperature-rise criteria with additional indicators such as cell voltage, maximum operating temperature, or venting [5,11,12,13]. Although these combined criteria improve the consistency of thermal runaway detection, they remain dependent on the measured cell temperature and do not consider vent gas temperature as a detection signal.
Given the variability in temperature sensor setups and thermal runaway criteria, combined with pronounced inter-cell variability, the objective of this paper is to investigate the impact of these factors and to identify easily implementable solutions to enhance the quality of future safety tests. Therefore, ten identical commercially available 18650-type cylindrical cells per test were investigated using thermal stability and lateral heating tests. In the first step, established thermal runaway criteria based on the cell temperature rise rate were compared with criteria based on the gas temperature rise rate. Further, the extent of intra- and inter-cell variability for safety-relevant parameters was investigated. Based on these results, a statistical investigation was conducted to evaluate whether increasing the number of measurement positions improves the accuracy of test results and thereby reduces the required sample size. This work provides a systematic framework to improve the reproducibility and comparability of lithium-ion battery safety tests by addressing two critical sources of uncertainty: temperature sensor positioning and thermal runaway definition.
The key contributions of this work are the following:
- A systematic comparison of thermal runaway criteria based on cell and gas temperature.
- A quantitative assessment of intra- and inter-cell variability in safety testing.
- A statistical evaluation of measurement configurations and their impact on sample size requirements.
- Practical recommendations for improving the reliability and comparability of battery safety tests.
2. Experimental
2.1. Thermal Safety Tests
In this study, a total of 20 commercially available 18650-format lithium-ion cells of the same type were investigated, featuring a nominal capacity of 2.8 Ah and a nominal voltage of . These cells were subjected to thermal stability and lateral heating tests, using ten samples per test type. The cell chemistry consisted of a LiNi0.8Mn0.1Co0.1O2 (NMC) cathode and a graphite anode.
Prior to safety testing, a reference performance test (RPT) was conducted to determine the actual cell capacity. This included three consecutive charge–discharge cycles at a C/3 rate, using a constant-current constant-voltage (CC-CV) charging and constant-current (CC) discharging protocol. The actual cell capacity was derived from the final discharge cycle. Furthermore, the direct current internal resistance (DCIR) was analyzed using a C-rate of 1.5 C. The RPT confirmed the comparability of the individual cells, with a standard deviation of 0.43% for cell capacity and 2.90% for DCIR at 50% state of charge () during discharging with 1.5 C. Following the RPT, cells were charged to 100% at 25 °C using CC-CV charging at C/3. Subsequently, the cells were transferred to an AT-S safety chamber (AVL List GmbH, Graz, Austria) for safety tests.
Temperature was measured using class 1 K-type NiCr-Ni temperature sensors (Therma Thermofühler GmbH, Lindlar, Germany). These sensors provided a precision of ±1.75 °C in the range of −40 °C to 375 °C and ±0.4% of the measured temperature in the range of 375 °C to 1000 °C, according to IEC 60584-1 [33]. As shown in Figure 1, temperature measurement was conducted at three different positions (top, center, bottom) on the cell surface and additionally 1 cm above the cell vent. For gas temperature measurement, the temperature sensor was mounted on a thin metal pin that was passed through a drilled hole in the back plate of the test setup and mechanically secured in place (see Supplementary Figure S1). The temperature sensor above the vent was included to study easily implementable thermal runaway criteria, based on an increase in gas temperature. For the thermal stability test, two temperature sensors were used per position, whereas for the lateral heating test, one temperature sensor was used per position. To prevent contact loss between the temperature sensor and cell surface, the temperature sensors were secured with high-temperature polyimide tape (3M Company, St. Paul, MN, USA) with a temperature resistance up to 260 °C. Temperature was measured at a frequency of 10 .
Figure 1.
Setup for temperature measurement in the thermal stability and lateral heating tests. Temperature was measured at three distinct positions (top, center, bottom) on the cell surface, each 2 cm apart. Additionally, temperature measurement was conducted 1 cm above the vent to allow thermal runaway detection by an increase in gas temperature. In the thermal stability test, two temperature sensors were used per position, compared to one in the lateral heating test. Horizontal and vertical temperature differences were calculated over all three layers.
For evaluating battery cell safety, three safety-relevant parameters were determined: venting temperature , thermal runaway temperature , and maximum cell surface temperature . was determined by a drop in cell temperature [31,32,34]. Given the diverse thermal runaway criteria in test standards and the literature, typically based on changes in cell temperature per time, this study critically assessed the influence of the criteria shown in Table 1 on .
Table 1.
Thermal runaway criteria thresholds based on the rise in cell temperature over time from various test standards and publications.
was defined as the cell surface temperature at the moment when any of the six (thermal stability) or three (lateral heating) cell surface sensors first exceeded the respective threshold criterion. Analogously, the gas temperature at this moment was recorded from the gas sensor above the cell. was defined as the highest temperature recorded among all cell surface sensors during the entire test.
In order to evaluate the criteria introduced in this study, based on the gas temperature rise rate, four threshold values were investigated: , , , and . This approach was investigated as a potentially more robust alternative to conventional cell temperature-based criteria, which may be affected by local temperature inhomogeneities.
2.1.1. Thermal Stability Test
The thermal stability test was performed in an FD 260 oven (BINDER GmbH, Tuttlingen, Germany) installed within an AT-S safety chamber (AVL List GmbH, Graz, Austria), using a modified test procedure based on VW PV 8450-2024 [6]. In accordance with VW PV 8450-2024, the chamber temperature was initially increased to 60 °C and maintained for two hours to ensure thermal equilibrium within the cell. After this stabilization period, the temperature was raised to 130 °C at a rate of and held for 30 min. Unlike VW PV 8450-2024, where this step is followed by heating the oven directly to 200 °C at , the temperature was increased in 10 °C increments at a heating rate of , with each increment followed by a 15 min holding period, until thermal runaway occurred. This modification was implemented to increase the likelihood of detecting potential temperature gradients that could adversely affect the accuracy of the investigated safety-relevant parameters.
2.1.2. Lateral Heating Test
In the lateral heating tests, a flexible polyimide heating element (thermo Flächenheizungs GmbH, Rohrbach, Germany), with dimensions of mm, was positioned on the cell surface as shown in Figure 1. To limit heat loss to the environment, three layers of glass cloth band (R&G Faserverbundwerkstoffe GmbH, Waldenbuch, Germany) were wrapped around the cell and secured with high-temperature polyimide tape (3M). Heating was applied with a power of 30 W ± 3 W until thermal runaway occurred. Although cells and setups were prepared consistently, the average heating rate until thermal runaway exhibited a standard deviation of ±19%, as detailed in Supplementary Section S1.2.
2.2. Statistical Analyses
2.2.1. Variance Analysis and Effect Size
In order to determine whether measurement positions or inter-cell variability can systematically influence safety-relevant parameters, a variance analysis was conducted. Since the test data were not normally distributed, as verified by the Kolmogorov–Smirnov test [36,37], the Kruskal–Wallis test was employed as a non-parametric method for variance analysis. This test was used to evaluate whether there were significant differences in the median values between the three different measurement positions and whether there were differences between the ten cells. Unlike parametric methods, the Kruskal–Wallis test assesses the ranks of the data rather than their absolute values. The test statistic H was calculated based on the formula outlined in [36], where N denotes the total number of observations across all groups, denotes the number of observations in group j, denotes the sum of ranks for group j, and k denotes the number of groups (Equation (1)).
To assess statistical significance, the p-value was derived by comparing the calculated H value to a distribution with degrees of freedom. A p-value ≤ 0.05 indicates that at least one pair of groups exhibits a statistically significant difference in their population medians [36,37]. The distribution was used in this test because, under the null hypothesis of equal group medians, the H statistic approximately follows a distribution. This allowed the test to estimate the likelihood that the H value occurred by chance, even under the assumption of no real differences between groups.
In addition to variance analysis, the effect size, also referred to as effect strength, was calculated to quantify the magnitude of group differences. In this study, , adapted for the Kruskal–Wallis test, was used because it aligns with the rank-based, non-parametric nature of the test [38].
To address the potential limitations of with small sample sizes, was calculated as a complementary measure. provides a more conservative estimate of effect size, mitigating biases associated with smaller sample sizes and offering additional validation [39]. The calculation of was conducted according to [38] (Equation (3)).
Both and range from 0 to 1. To interpret these values, the effect size scale recommended by Cohen et al. [40] was applied (Table 2).
Table 2.
Interpretation of effect size and according to [40].
2.2.2. Influence of the Amount of Temperature Sensors on Sample Size Requirements
In addition to the statistical evaluation of the impact of inter-cell variability and measurement position on variance, this study investigated whether increasing the number of temperature sensors could reduce the required sample size for and and for in case of similar thermal runaway behavior. For this analysis, the probability density function (PDF) based on all ten cells and all temperature sensors served as a reference. Subsequently, PDFs for different test scenarios, which were defined by the authors and varied in the number of tested cells and temperature sensors, were calculated and compared to the reference. These test scenarios were designed individually for the thermal stability and lateral heating test because of differences in the sensor configuration.
For the thermal stability test, the following three scenarios were defined:
- Scenario 1: Ten cells with three temperature sensors (one per position).
- Scenario 2: Five cells with six temperature sensors at three positions.
- Scenario 3: Ten cells with one temperature sensor at the cell center.
For the lateral heating test, the following two scenarios were defined:
- Scenario 1: Five cells with all three temperatures sensors.
- Scenario 2: Ten cells with one temperature sensor at the cell center.
To guarantee a statistically representative evaluation, 10,000 bootstrap samples were drawn for each scenario [41,42]. This large amount of samples was chosen to minimize the influence of outliers and ensured reliability. For each sample, the Kolmogorov–Smirnov test was performed [36,37], using the PDF derived from ten cells and all sensors as the reference. The accuracy of the approximation was quantified using the D-value [36], which quantifies the absolute differences between the sample and the reference PDF.
3. Results and Discussion
This section first evaluates whether thermal runaway criteria based on cell or gas temperature rise rate are more suitable for determining (Section 3.1). Subsequently, a detailed analysis of intra- and inter-cell variability, the systematic effects of sensor position, and the influence of the number of measurement positions on the required sample size is conducted for , , and based on the thermal stability test (Section 3.2, Section 3.3 and Section 3.4). The transferability of these findings to the lateral heating test is then assessed (Section 3.5), followed by a summary of all results and their implications (Section 3.6).
3.1. How Does the Choice of Thermal Runaway Criteria Affect the Thermal Runaway Temperature?
In order to ensure a precise and robust identification of , various thermal runaway criteria (Table 1) were evaluated in the first step. was defined as the point at which the first temperature sensor surpassed the respective threshold value for the temperature rise rate. At this point, the values of all temperature sensors were collected and used for subsequent calculations. Table 3 and Table 4 provide an overview of the impact of these criteria for thermal stability and lateral heating tests. In addition to criteria based on cell temperature rise rate, four criteria based on changes in the gas temperature rise rate were investigated. As the maximum heating rate of the cell in the lateral heating exceeded , criteria below this threshold were excluded from evaluation (see Supplementary Figure S3).
Table 3.
Comparison of criteria for in the thermal stability test, according to Section 2.1.1, using different criteria based on the median, standard deviation, and interquartile range (IQR) of ten investigated cells. Established criteria from test standards and the literature based on changes in cell temperature over time were compared to criteria based on change in gas temperature measured above the cell vent.
Table 4.
Comparison of criteria for in the lateral heating test, according to Section 2.1.2, using different criteria based on the median, standard deviation, and interquartile range of ten investigated cells. Established criteria from test standards and the literature based on changes in cell temperature over time were compared to criteria based on change in gas temperature measured above the cell vent.
The results from Table 3 and Table 4 highlighted that criteria based on cell temperature rise rate could vary significantly, depending on the selected threshold value. Given the variety of criteria used in different studies, these findings demonstrated that comparability is often limited. The investigated criteria based on changes in the gas temperature rise rate exhibited only minor differences between the different threshold values, if no premature detection of occurred. Based on the investigated cell, the threshold value should be at least . In case of an increased risk of incorrect detections of in other cells, an increase to >25 and >100 was shown to have only a minor influence on the detected in the thermal stability test. However, in the lateral heating test, where low threshold values (>1 and >10 ) also caused false identification of as in some cells, a threshold of >100 resulted in a higher standard deviation (20.2 °C) compared to >25 (15.3 °C). Therefore, a threshold of >25 was selected as it offered a favorable balance between robustness against false detection and low variability.
Accurately identifying thermal runaway based on changes in the cell temperature rise rate is generally challenging. For the investigated cell, a cell temperature rise rate of >1 corresponded to using the gas temperature rise rate in both tests, while other criteria, such as , identified temperatures prior to the initiation of thermal runaway. A higher threshold value such as detected while the thermal runaway was already ongoing. These results suggest that using criteria based on gas temperature provides higher precision and reduces the risk of incorrect identification of the thermal runaway event. In comparison to conventional cell surface temperature-based criteria, this approach provides a more robust and less ambiguous indication of thermal runaway, as it is less sensitive to local temperature gradients and sensor positioning effects.
The thermal runaway criteria specified in multiple standards [5,11,12,13], which combine the temperature rise rate with voltage drop or the maximum operating temperature mark an important step towards further harmonization. However, as the temperature rise rate is determined using cell temperature, the reliability remains dependent on whether the selected measurement position adequately represents the thermal behavior of the cell. Gas temperature-based criteria therefore complement these criteria by reducing the influence of sensor positioning on thermal runaway identification.
In addition to these factors, criteria based on the cell temperature rise rate were inherently influenced by the measurement position on the cell surface. As shown in Figure 2, both the absolute temperature and its rise rate varied between positions. A detailed analysis of this intra-cell variability is provided in Section 3.2. Under thermal abuse, a cascade of exothermic reactions causes an increase in cell temperature [14,15,16,17,18]. Once a critical temperature is reached, cathodic phase transition leads to oxygen release [43,44,45]. The subsequent highly exothermic reaction of oxygen with the electrolyte [46] and the anode [47] are the primary drivers of thermal runaway. These exothermic reactions generate internal temperature gradients, which cause the initiation position of thermal runaway to vary from test to test.
Figure 2.
Exemplary overview of the cell and gas temperature (a), and the cell and gas temperature rise rate (b) during thermal runaway in the thermal stability test. Temperature was measured at three distinct positions (top, center, bottom) on the cell using six temperature sensors and one additional temperature sensor placed 1 cm above the cell vent for gas temperature measurement.
The variation in heat transfer pathways within the cells, observed in the conducted experiments, was attributed to the internal temperature gradients generated by exothermic reactions [48,49]. As a result, could be detected with a delay when thermal runaway initiated in regions insufficiently covered by temperature sensors. Although this phenomenon was already evident in the comparatively small 18650-type cylindrical cell investigated in this study, findings by Zou et al. suggest that the delay may be even more pronounced in larger prismatic cells [50]. In contrast, criteria based on the gas temperature rise rate are inherently independent of the initiation position and internal heat transfer constraints, providing a more robust method for identifying thermal runaway.
Although other methods for identifying thermal runaway, such as chemical gas sensors and audio signals [31,32], exist, no additional equipment is required to analyze , because temperature measurement is already required in established standards for thermal safety tests [1,2,3,4,5,6,7,8,9,10,11]. Criteria based on voltage changes present an alternative [30], but they are not universally applicable to cylindrical cells, as they often include current interrupt devices [51]. Furthermore, if thermal runaway occurs prior to an internal short circuit (ISC) [47], detection is also impossible. In contrast, criteria based on changes in the gas temperature rise rate have been shown to provide a precise, cost-efficient thermal runaway detection that is simple to implement. The results of this study, based on 18650-type cylindrical cells, are likely transferable to prismatic cells with a venting mechanism. However, for pouch cells with variable venting locations, reliable application would require multiple temperature sensors positioned along the pouch cell’s sealing regions. For the investigated cell, the gas temperature sensor was positioned centrally above the vent at a distance of 1 , as illustrated in Figure 1. This configuration provided a robust and fast approach for thermal runaway identification. However, sensor distance and alignment relative to the vent opening may affect the measured temperature rise rate due to mixing with ambient air and cooling of the vent gas. Therefore, the suitability of this sensor position should be separately evaluated for other vent geometries and cell formats, such as large format prismatic and pouch cells.
These findings suggest that gas temperature-based criteria represent a promising pathway toward more standardized and comparable thermal runaway detection in lithium-ion battery safety testing.
3.2. How Are Test Results Influenced by Intra- and Inter-Cell Variability?
In order to assess the influence of intra- and inter-cell variability on thermal safety test results, three distinct safety-relevant parameters were evaluated according to Section 2.1. Intra-cell variability was determined based on all cell surface sensors per cell (six in the thermal stability test, three in the lateral heating test). Additionally, the maximum vertical temperature difference was determined as the maximum difference between all three measurement levels (top, center, bottom), while the maximum horizontal temperature difference was determined as the maximum difference between the two opposing sensors within each level (Figure 1). The thermal runaway temperature, , was determined using the criterion , as discussed in Section 3.1. The subsequent analysis focuses on the thermal stability test. A comparison with the lateral heating test is provided in Section 3.5. An overview of the range of , , and for the thermal stability test is presented in Figure 3, which illustrates significant intra- and inter-cell variability. Of the ten cells in the thermal stability test, all ten reached hazard level 6 (fire or flame) according to SAE J2464 [4]. In the lateral heating, eight cells underwent hazard level 6, while two cells exhibited hazard level 7 (Supplementary Figure S4).
Figure 3.
Box plots showing the temperature distribution for (a), (b), and (c) in the thermal stability test. The results were based on six temperature sensors, measured at three positions (top, center, bottom) and shown for all ten cells and individually for each cell.
Figure 4a–c illustrates the maximum temperature differences within the cells vertical and horizontal directions. For , except for cell two, temperature differences were within measurement accuracy of the K-type thermocouples (±1.75 °C), indicating an almost uniform surface temperature. For and especially , intra-cell differences were more pronounced, consistent with Finegan et al. [48,52]. Some deviations in likely resulted from sensor detachment, as the polyimide tape may have lost adhesion above 260 °C. Vertical gradients were slightly higher than horizontal gradients, showing that insufficient sensor coverage could have affected the results and highlighting the importance of optimized sensor placement. Inter-cell variability is analyzed in Figure 4d, which shows the maximum temperature differences among the ten cells. Across all parameters, inter-cell variability exceeded intra-cell variability, demonstrating that individual cells behaved differently even under identical conditions.
Figure 4.
Maximum temperature differences obtained in the thermal stability test. Differences between the maximum and the minimum temperature of all six temperature sensors were calculated for each individual cell and are displayed for (a), (b), and (c). To quantify the extent of temperature differences between the ten tested cells, the maximum differences at the respective measurement positions are shown in (d).
Overall, both intra- and inter-cell variability strongly affected the measured , , and . Given these differences, using too few sensors or small sample sizes may lead to misinterpretation of test results due to inhomogeneous temperature distributions and inherent cell-to-cell variability.
Across all parameters, higher temperatures were consistently observed at the cell top, likely caused by the Joule–Thomson effect. During venting at and , and shortly before reaching , rapid gas ejection through the top vent caused adiabatic expansion and local cooling at the cell top [34,53]. This effect predominantly influenced the vertical temperature distribution, resulting in tending to be higher than . Variations in the gas generation rate, flow pathways, and the location of thermal runaway initiation further influenced these effects [48,49]. Previous studies have reported substantial inter-cell variability for , , and [19,28,29,54]. Although no systematic study on intra-cell variability exists, Finegan et al. [48,52] demonstrated substantial surface temperature variation at and using thermal imaging.
3.3. Are the Outcomes of Thermal Safety Tests Dependent on Measurement Position and Cell?
Given the influence of intra- and inter-cell temperature differences on safety-relevant parameters (Section 3.2), it was crucial to analyze whether systematic differences existed between measurement positions or individual cells. Therefore, a variance analysis based on the Kruskal–Wallis test was conducted for the three different measurement positions and for the ten individual cells. The Kruskal–Wallis test was chosen as a non-parametric method, as it is applicable to non-normally distributed data [36]. In the Kruskal–Wallis test (Figure 5a), the p-value indicated whether temperature differences across positions or cells were statistically significant (p-value < 0.05 [36,37]). In addition to the p-value, the effect size , adapted for rank-based, non-parametric data, was calculated to quantify the strength of the observed differences (Figure 5b).
Figure 5.
Variance analysis of the influence of measurement position and individual cells on the variance in the thermal stability test. The p-value is shown for the Kruskal–Wallis test to identify whether differences between positions and between cells are significant (p-value < 0.05) (a). Additionally, the effect size is presented as a measure of the magnitude of differences between positions and between cells (b).
The Kruskal–Wallis test revealed a statistically significant influence of individual cells on , indicating systematic variance among the ten cells. This aligned with the findings from Figure 3a, which demonstrated significant differences in between the ten cells. For , however, the measurement position systematically influenced the results. The lowest was measured in the top area of the cell, while the highest occurred at the bottom area of the cell (Supplementary Section S1.4). This trend was presumably attributed to cooling caused by the Joule–Thomson effect. Since the amount of gas ejected during thermal runaway was substantially larger compared to that at [19,21], it was assumed that the cooling effect at is greater compared to .
Effect size analysis, based on , further supported these findings. Variance in stemmed from inter-cell variability, suggesting that differences in gas generation rate and internal cell pressure increase were the primary contributors. In contrast, the differences in were strongly influenced by the measurement position, highlighting systematic phenomena such as localized cooling. For , the analysis indicated a medium effect of measurement position, suggesting that systematic cooling effects also played a role. Finegan et al. [49] demonstrated that the highest surface temperature during thermal runaway occurs close to the position of ISC and thermal runaway initiation. Given the random distribution of ISC and the thermal runaway initiation position in this study, stochastic variability in temperature distribution is likely. Therefore, the medium effect of measurement position was presumably influenced by systematic effects and stochastic event variability. The effect size analysis based on showed similar effect strength across all parameters (see Supplementary Figure S6).
The significant differences observed between measurement positions for critically affected the interpretation of test results. Measurements from different positions could not be directly compared or assumed to represent the behavior of all cells. For standardized testing, this highlights the need for precise definition of measurement locations to ensure consistent and comparable results. The relevance of this trend to other cell types, chemistries, or thermal safety tests remains unclear. While variations in cell type and chemistry were beyond the scope of this study, a comparison with the lateral heating test is provided in Section 3.5.
Regarding , the results suggest that the actual probability distribution can only be reliably identified by increasing the sample size. A detailed analysis of the influence of sample size and number of measurement positions is included in the subsequent section.
3.4. Can an Increase in Measurement Points Reduce the Required Sample Size?
The observed extent of intra- and inter-cell variability raises the question of whether simple modifications to the test setup, such as increasing the number of measurement positions, can reduce the required sample size. To investigate this, the PDFs of three different scenarios, varying in sample size and number of measurement positions (Section 2.2.2), were compared to the PDF of all ten cells and all six temperature sensors at three measurement positions using the Kolmogorov–Smirnov test [36]. Differences between these PDFs were quantified by calculating the D-value for 10,000 samples per scenario (Figure 6).
Figure 6.
Analysis of the accuracy of approximating the reference PDF for safety-relevant parameters in the thermal stability test, based on D-value for three different scenarios. The reference PDF is based on all ten tested cells and all six temperature sensors at three measurement positions, while the scenarios vary in the number of tested cells and measurement positions. The D-value range is selected according to Cohen et al. [40].
The results indicate that the benefit of increasing the number of measurement positions depends on the safety-relevant parameter. For , increasing the number of temperature sensors did not improve the accuracy of smaller sample sizes, as variance was primarily attributed to inter-cell variability (Figure 5). In contrast, for and , where variance mainly stemmed from intra-cell variability, adding more temperature sensors significantly improved accuracy, thereby reducing the required sample size.
Although the precision required for PDF approximation is dependent on the research question, the findings indicate that increasing the number of K-type temperature sensors can substantially enhance the quality of information obtained from thermal stability tests. This approach is particularly valuable given the constraints of limited sample sizes, costs, and time demands associated with safety tests. However, as the results regarding the required number of measurement positions were derived from a comparatively small 18650-type cylindrical cell, no conclusion can be drawn for other cell formats and cell chemistries. Further studies are necessary to investigate these effects across various test types and battery designs.
The strong influence of measurement position emphasizes the need for greater standardization in thermal safety testing. Considering the diversity of cell sizes and geometries, defining the required number of temperature sensors relative to the cells’ surface area is recommended. In this approach, smaller cells would require a higher temperature sensor density than larger cells, as local temperature gradients represent a larger fraction of the total cell surface and can therefore affect the results more significantly. A comparable scaling principle is already applied for the impactor diameter in the SAND2017-6925 crush test procedure [3].
3.5. Are Findings from the Thermal Stability Test Transferable to a Lateral Heating Test?
In order to determine whether the findings from the thermal stability test are applicable to other thermal safety tests, the analyses presented in Section 3.2, Section 3.3 and Section 3.4 were repeated for the lateral heating test. In contrast to the thermal stability test, surface temperature differences were measured only in the vertical direction on one side, due to the requirement to use a heating pad on one side of the cell (see Figure 1).
As in the thermal stability test, pronounced intra- and inter-cell variations were observed (Figure 7), indicating that these variations are not specific to a particular thermal safety test. Inter-cell variability in and was more pronounced, primarily due to differences in the heating rate [55,56] (see Supplementary Figure S2) and hazard level [29] (see Supplementary Figure S4). This highlights that external parameters, such as heating power, can amplify variability and reduce reproducibility. Furthermore, strong differences in intra-cell variability between individual cells for indicated that three temperature sensors were insufficient to accurately capture the temperature distribution during thermal runaway, in contrast to the six sensors used in the thermal stability test.
Figure 7.
Maximum temperature differences obtained in the lateral heating test. The differences between the maximum and the minimum temperature of all three temperature sensors at three measurement positions were calculated for each individual cell and are shown for (a), (b), and (c). To quantify temperature differences between the ten tested cells, the maximum differences at the respective measurement positions are shown in (d).
Statistical analysis confirmed the findings from the thermal stability test. The Kruskal–Wallis test revealed a significant effect of measurement position on (Figure 8a). The top position showed the highest variability (see Supplementary Figure S5), consistent with the results from the thermal stability test. Effect size analysis indicated (Figure 8b) that intra-cell differences affected and similarly to the thermal stability test. In contrast to the thermal stability test, the lateral heating test showed a strong influence of measurement position for and . This was likely due to the higher heating rate in the lateral heating test, which limited temperature homogenization and amplified the impact of local temperature gradients. The effect size analysis based on further supported these findings (see Supplementary Figure S6).
Figure 8.
Variance analysis on the influence of measurement position and inter-cell variability in the lateral heating test. The p-value is shown for the Kruskal–Wallis test to determine whether differences between positions and between cells were significant (p-value < 0.05) (a). Additionally, the effect size is presented as a measure of the magnitude of differences between positions and between cells (b).
Analogous to the thermal stability test, the sample size analysis by D-value (Figure 9) showed that, for and , increasing the number of sensors while reducing the number of tested cells improved the test accuracy. For , however, strong differences between cells limited this improvement, further highlighting the insufficiency of three sensors to accurately capture the temperature distribution on the cells’ surface during thermal runaway.
Figure 9.
Analysis of the accuracy of approximating the reference PDF for safety-relevant parameters in the lateral heating test, based on D-value for two different scenarios. The reference PDF is based on all ten tested cells and all three measurement positions, while the scenarios vary in the number of tested cells and measurement positions. The D-value range was selected according to Cohen et al. [40].
In summary, the lateral heating test confirmed the main conclusions from the thermal stability test. Both test types demonstrated that intra- and inter-cell variability significantly affected all safety-relevant parameters and that increasing the number of temperature sensors enhanced accuracy and reliability. The findings from the thermal stability test were largely transferable to the lateral heating test, with deviations mainly attributed to differences in the heating rate, hazard level, and insufficient temperature sensor density for precise measurement of .
3.6. How Can Adjustments in Test Setup and Parameter Definition Improve the Quality of Thermal Safety Tests?
As demonstrated in Section 3.1, Section 3.2 and Section 3.4, the choice of the thermal runaway criterion, intra- and inter-cell variability, and temperature sensor quantity can significantly affect the results of safety tests. A schematic summary of these effects and how adjustments in the choice of thermal runaway criteria and temperature measurement can improve test quality is presented in Figure 10.
Figure 10.
Overview of the impact of thermal runaway criteria and temperature sensor adjustments on the accuracy and reliability of safety test results.
The results highlight that novel thermal runaway criteria, based on the change in the gas temperature rise rate, allowed a precise and robust identification of thermal runaway. In contrast to established criteria based on the cell temperature rise rate [4,5,6,11], the applied threshold value had a negligible effect on the measured , while minimizing the risk of premature or delayed thermal runaway identification. Furthermore, thermal runaway identification by temperature rise rate was unaffected by the amount and position of temperature sensors on the cell surface, as the measurement was independent of thermal runaway initiation position. Based on these findings, a combined measurement strategy is recommended. Vent gas temperature can provide a robust signal for identifying the thermal runaway event, while spatially distributed cell surface sensors remain necessary to quantify the thermal behavior, local temperature differences, and maximum cell surface temperature. Gas and cell surface temperature measurements should therefore be considered complementary rather than interchangeable.
While common safety test standards lack a clear definition of the position and quantity of temperature sensors [1,2,3,4,5,6,7,8,9,10,11], adding temperature sensors was shown to significantly improve the quality of the assessment of most safety-relevant parameters. As this effect was shown for 18650-type lithium-ion cells with a NMC811/Gr chemistry, the findings may not be directly applicable to other cell types, such as prismatic and pouch cells. Even though Doose et al. [57] have demonstrated that temperature differences on the cell surface decrease with an increase in capacity in nail penetration tests of pouch cells, it remains unclear whether these findings also apply to thermal safety tests. However, given the extent of intra-cell variability in these small cells, it is considered likely that similar improvements could be achieved when testing larger cells and formats. The larger dimensions, different internal heat-transfer pathways, and potentially different venting locations of larger prismatic and pouch cells may require format-specific sensor distributions. Although the specific sensor configuration cannot be transferred directly, the statistical approach can be applied using format-specific reference measurements to evaluate suitable combinations of sensor position, sensor number, and sample size. Testing large-format prismatic and pouch cells therefore remains an important topic for future work. A potential approach is to define the quantity of temperature sensors and their placement based on cell size, similar to the impactor diameter, which is dependent on cell diameter and width in SAND2017-6925 [3].
4. Conclusions
This study investigated how test setup and parameter definitions affect thermal safety tests for lithium-ion batteries. Using thermal stability and lateral heating tests on a cylindrical 18650-type NMC811/graphite battery cell, the influence of thermal runaway definitions, inter- and intra-cell variability, measurement position, individual cell behavior, and the number of temperature sensors was evaluated.
The findings highlight that insufficient temperature measurement strategies may lead to systematic misinterpretation of safety tests, potentially affecting safety validation procedures in both research and industry. At the same time, the results demonstrate that relatively simple and easily implementable modifications can significantly improve the quality and reliability of thermal safety testing.
In particular, the following key insights can be derived:
- Criteria based on the gas temperature rise rate enable a more precise, robust, and less position-dependent identification of thermal runaway, largely unaffected by threshold value and initiation location.
- Both intra- and inter-cell variability strongly influence test outcomes and must be considered in experimental design.
- Measurements on the cell surface area near the vent systematically underestimate due to localized cooling from gas venting (Joule–Thomson effect).
- Increasing the number of temperature sensors improves the accuracy of safety-relevant parameters and may reduce the required sample size.
In general, this study provides a systematic framework for improving the reproducibility and comparability of lithium-ion battery safety tests. The presented approach contributes to the standardization of safety testing methodologies and enables a more reliable interpretation of safety-relevant parameters across different studies and test configurations.
While the present work is limited to a single cell type, the findings indicate fundamental measurement-related effects that are likely transferable to other systems. Further investigations across different cell types, chemistries, and test conditions are therefore required, alongside continued efforts toward harmonized test setups and clearly defined evaluation criteria.
Supplementary Materials
The following supporting information can be downloaded at https://www.mdpi.com/article/10.3390/esa3040016/s1: Figure S1: Schematic overview of the test setups used for the thermal stability and lateral heating tests. The cell was secured using a clamping fixture to prevent movement. In addition to three temperature sensors on the cell surface, one temperature sensor was positioned 1 cm above the cell vent and attached to a metal pin secured to the backplate; Figure S2: Cell-specific thermal runaway parameters and heating rates in the lateral heating test. (a) Thermal runaway temperature, , and time until thermal runaway, , for the ten investigated cells. (b) Average heating rate until for the ten investigated cells; Figure S3: Exemplary cell temperature profile and cumulative duration for which the cell temperature rise rate exceeded during the lateral heating test. The repeated exceedance of this threshold before demonstrates the risk of premature thermal runaway identification; Figure S4: Differences in cell case damage following thermal runaway. Hazard level 6 was characterized by fire or flame (a). During lateral heating, two of the ten cells reached hazard level 7, which was characterized by energetic failure, including flying parts of the cell case after top rupture (b,c) and complete loss of mechanical integrity (d); Figure S5: Box plots of the temperature distributions for the safety-relevant parameters and as a function of temperature sensor position. was determined using ; Figure S6: Variance analysis of the influence of measurement position and inter-cell variability in the thermal stability test (a) and lateral heating test (b). In addition to the Kruskal–Wallis effect size , the effect size is presented as a complementary measure of the magnitude of differences between positions and cells. References cited in the Supplementary Materials are included in the reference list of the main manuscript [4,31,35,39,55,56,58].
Author Contributions
Conceptualization, D.S., M.L. and A.K.; methodology, D.S. and M.L.; software, D.S.; validation, D.S. and M.L.; formal analysis, D.S. and M.L.; investigation, D.S.; data curation, D.S.; writing—original draft preparation, D.S.; writing—review and editing, M.L. and A.K.; visualization, D.S.; supervision, M.L. and A.K. All authors have read and agreed to the published version of the manuscript.
Funding
This research was funded by Volkswagen AG.
Data Availability Statement
Restrictions apply to the availability of these data. The data were obtained from Volkswagen AG and cannot be shared publicly. Access to the data may be granted by the authors with prior permission from Volkswagen AG.
Acknowledgments
The authors gratefully acknowledge Volkswagen AG and PowerCo SE for funding this research and making its realization possible.
Conflicts of Interest
Daniel Stiller was employed by Volkswagen AG and worked at PowerCo SE within the Volkswagen Group during the preparation of this work. Mechthild Lübke is employed by PowerCo SE. The research was funded by Volkswagen AG. The employers and funding sponsor had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript; or in the decision to publish the results beyond the scientific contributions disclosed in the Author Contributions statement. Arno Kwade declares no conflicts of interest.
Abbreviations
The following abbreviations are used in this manuscript:
| Cell temperature rise rate | |
| Gas temperature rise rate | |
| Non-parametric effect size | |
| Effect size adapted for Kruskal–Wallis test | |
| H | Kruskal–Wallis test statistic |
| j | Group index |
| k | Total number of groups |
| Number of observations in group j | |
| N | Total number of observations across all groups |
| Sum of ranks for group j | |
| SoC | State of charge |
| Maximum cell surface temperature | |
| Cell surface temperature at thermal runaway | |
| Cell surface temperature at first venting | |
| CC | Constant current |
| CC-CV | Constant current–constant voltage |
| DCIR | Direct current internal resistance |
| Gr | Graphite |
| IQR | Interquartile range |
| ISC | Internal short circuit |
| NMC | Nickel manganese cobalt oxide |
| Probability density function | |
| RPT | Reference performance test |
| TR | Thermal runaway |
References
- UL 1973; Standard for Safety—Batteries for Use in Stationary and Motive Auxiliary Power Applications. Underwriters Laboratories: Northbrook, IL, USA, 2022.
- UL 2580; Standard for Safety—Batteries for Use in Electric Vehicles. Underwriters Laboratories: Northbrook, IL, USA, 2021.
- Sandia National Laboratories (SNL). FreedomCAR—Recommended Practices for Abuse Testing Rechargeable Energy Storage Systems (RESSs); Sandia National Laboratories (SNL): Albuquerque, NM, USA, 2017. [Google Scholar]
- J2464_202108; Electric and Hybrid Electric Vehicle Rechargeable Energy Storage System (RESS) Safety and Abuse Testing. Battery Safety Standards Committee: Warrendale, PA, USA, 2021. [CrossRef] [Scilit]
- ISO 6469-1:2019; Electrically Propelled Road Vehicles—Safety Specifications RESS. ISO: Geneva, Switzerland, 2022.
- PV 8450; Lithium-Ion Battery Cells for Automotive Applications—Test Conditions. Volkswagen AG: Wolfsburg, Germany, 2024.
- IEC 62660-3:2022; Secondary Lithium-Ion Cells for the Propulsion of Electric Road Vehicles Part 3: Safety Requirements. IEC: Geneva, Switzerland, 2022.
- Sandia National Laboratories (SNL). FreedomCAR—Electrical Energy Storage System Abuse Test Manual for Electric and Hybrid Electric Verhicle Applications; Sandia National Laboratories (SNL): Albuquerque, NM, USA, 2006. [Google Scholar]
- GB 38031-2020; Electric Vehicles Traction Battery Safety Requirements. State Administration for Market Regulation: Beijing, China; Standardization Administration of the People’s Republic of China: Beijing, China, 2020.
- GB/T 31485; Safety Requirements and Test Methods for Traction Battery of Electric Vehicle. General Administration of Quality Supervision, Inspection and Quarantine of the People’s Republic of China: Beijing, China; Standardization Administration of the People’s Republic of China: Beijing, China, 2015.
- GTR20; UN Global Technical Regulation No. 20: Global Technical Regulation on Electric Vehicle Safety (EVS). United Nations Economic Commission for Europe: Geneva, Switzerland, 2018.
- GB 38031-2025; Electric Vehicles Traction Battery Safety Requirements. State Administration for Market Regulation: Beijing, China; Standardization Administration of the People’s Republic of China: Beijing, China, 2025.
- ECER100.05; Proposal for the 05 Series of Amendments to UN Regulation No. 100 (Electric Power Trained Vehicles). United Nations Economic Commission for Europe: Geneva, Switzerland, 2025.
- Feng, X.; Zheng, S.; He, X.; Wang, L.; Wang, Y.; Ren, D.; Ouyang, M. Time Sequence Map for Interpreting the Thermal Runaway Mechanism of Lithium-Ion Batteries With LiNixCoyMnzO2 Cathode. Front. Energy Res. 2018, 6, 264. [Google Scholar] [CrossRef] [Scilit]
- Feng, X.; Ouyang, M.; Liu, X.; Lu, L.; Xia, Y.; He, X. Thermal runaway mechanism of lithium ion battery for electric vehicles: A review. Energy Storage Mater. 2018, 10, 246–267. [Google Scholar] [CrossRef] [Scilit]
- Richard, M.N.; Dahn, J.R. Accelerating Rate Calorimetry Study on the Thermal Stability of Lithium Intercalated Graphite in Electrolyte. I. Experimental. J. Electrochem. Soc. 1999, 146, 2068. [Google Scholar] [CrossRef] [Scilit]
- Mao, B.; Huang, P.; Chen, H.; Wang, Q.; Sun, J. Self-heating reaction and thermal runaway criticality of the lithium ion battery. Int. J. Heat Mass Transf. 2020, 149, 119178. [Google Scholar] [CrossRef] [Scilit]
- Wang, Q.; Ping, P.; Zhao, X.; Chu, G.; Sun, J.; Chen, C. Thermal runaway caused fire and explosion of lithium ion battery. J. Power Sources 2012, 208, 210–224. [Google Scholar] [CrossRef] [Scilit]
- Golubkov, A.W.; Planteu, R.; Krohn, P.; Rasch, B.; Brunnsteiner, B.; Thaler, A.; Hacker, V. Thermal runaway of large automotive Li-ion batteries. RSC Adv. 2018, 8, 40172–40186. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Schaeffler, S.; Jossen, A. In situ measurement and modeling of internal thermal runaway propagation within lithium-ion cells under local overheating conditions. J. Power Sources 2024, 614, 234968. [Google Scholar] [CrossRef] [Scilit]
- Essl, C.; Golubkov, A.W.; Gasser, E.; Nachtnebel, M.; Zankel, A.; Ewert, E.; Fuchs, A. Comprehensive Hazard Analysis of Failing Automotive Lithium-Ion Batteries in Overtemperature Experiments. Batteries 2020, 6, 30. [Google Scholar] [CrossRef] [Scilit]
- Essl, C.; Golubkov, A.; Fuchs, A. Comparing Different Thermal Runaway Triggers for Two Automotive Lithium-Ion Battery Cell Types. J. Electrochem. Soc. 2020, 167, 130542. [Google Scholar] [CrossRef] [Scilit]
- Fedoryshyna, Y.; Schaeffler, S.; Soellner, J.; Gillich, E.; Jossen, A. Quantification of venting behavior of cylindrical lithium-ion and sodium-ion batteries during thermal runaway. J. Power Sources 2024, 615, 235064. [Google Scholar] [CrossRef] [Scilit]
- Bausch, B.; Frankl, S.; Becher, D.; Menz, F.; Baier, T.; Bauer, M.; Böse, O.; Hölzle, M. Naturally-derived thermal barrier based on fiber-reinforced hydrogel for the prevention of thermal runaway propagation in high-energetic lithium-ion battery packs. J. Energy Storage 2023, 61, 106841. [Google Scholar] [CrossRef] [Scilit]
- Walker, W.Q.; Darst, J.J.; Finegan, D.P.; Bayles, G.A.; Johnson, K.L.; Darcy, E.C.; Rickman, S.L. Decoupling of heat generated from ejected and non-ejected contents of 18650-format lithium-ion cells using statistical methods. J. Power Sources 2019, 415, 207–218. [Google Scholar] [CrossRef] [Scilit]
- Walker, W.; Cooper, K.; Hughes, P.; Doemling, I.; Akhnoukh, M.; Taylor, S.; Darst, J.; Billman, J.; Sharp, M.; Petrushenko, D.; et al. The effect of cell geometry and trigger method on the risks associated with thermal runaway of lithium-ion batteries. J. Power Sources 2022, 524, 230645. [Google Scholar] [CrossRef] [Scilit]
- Sharp, M.D.; Darst, J.; Hughes, P.; Billman, J.A.; Pham, M.; Petrushenko, D.; Heenan, T.M.M.; Jervis, R.; Owen, R.E.; Patel, D.; et al. Thermal Runaway of Li-Ion Cells: How Internal Dynamics, Mass Ejection, and Heat Vary with Cell Geometry and Abuse Type. J. Electrochem. Soc. 2022, 169, 020526. [Google Scholar] [CrossRef] [Scilit]
- Zeng, L.; Zeng, L. Cell-to-cell variability in Li-ion battery thermal runaway: Experimental testing, statistical analysis, and kinetic modeling. J. Energy Storage 2022, 56, 106024. [Google Scholar] [CrossRef] [Scilit]
- Stiller, D.; Lübke, M.; Kwade, A. Effect of sample size on safety tests of lithium-ion batteries using statistical methods. J. Energy Storage 2025, 139, 118814. [Google Scholar] [CrossRef] [Scilit]
- Feng, X.; Fang, M.; He, X.; Ouyang, M.; Lu, L.; Wang, H.; Zhang, M. Thermal runaway features of large format prismatic lithium ion battery using extended volume accelerating rate calorimetry. J. Power Sources 2014, 255, 294–301. [Google Scholar] [CrossRef] [Scilit]
- Feinauer, M.; Abd-El-Latif, A.A.; Sichler, P.; Aracil Regalado, A.; Wohlfahrt-Mehrens, M.; Waldmann, T. Change of safety by main aging mechanism—A multi-sensor accelerating rate calorimetry study with commercial Li-ion pouch cells. J. Power Sources 2023, 570, 233046. [Google Scholar] [CrossRef] [Scilit]
- Abd-El-Latif, A.A.; Sichler, P.; Kasper, M.; Waldmann, T.; Wohlfahrt-Mehrens, M. Insights Into Thermal Runaway of Li–Ion Cells by Accelerating Rate Calorimetry Coupled with External Sensors and Online Gas Analysis. Batter. Supercaps 2021, 4, 1135–1144. [Google Scholar] [CrossRef] [Scilit]
- IEC 60584-1; Thermocouples—Part 1: EMF Specifications and Tolerances. International Electrotechnical Commission: Geneva, Switzerland, 2013.
- Golubkov, A.W.; Fuchs, D.; Wagner, J.; Wiltsche, H.; Stangl, C.; Fauler, G.; Voitic, G.; Thaler, A.; Hacker, V. Thermal-runaway experiments on consumer Li-ion batteries with metal-oxide and olivin-type cathodes. RSC Adv. 2014, 4, 3633–3642. [Google Scholar] [CrossRef] [Scilit]
- Cai, Z.; Mendoza, S.; Goodman, J.; McGann, J.; Han, B.; Sanchez, H.; Spray, R. The Influence of Cycling, Temperature, and Electrode Gapping on the Safety of Prismatic Lithium-Ion Batteries. J. Electrochem. Soc. 2020, 167, 160515. [Google Scholar] [CrossRef] [Scilit]
- Sheskin, D.J. Handbook of Parametric and Nonparametric Statistical Procedures; Chapman and Hall/CRC: Boca Raton, FL, USA, 2003. [Google Scholar] [CrossRef] [Scilit]
- Wasserman, L. All of Statistics: A Concise Course in Statistical Inference; Springer Texts in Statistics; Springer: New York, NY, USA, 2013. [Google Scholar] [CrossRef] [Scilit]
- Tomczak, M.; Tomczak, E. The need to report effect size estimates revisited. An overview of some recommended measures of effect size. Trends Sport Sci. 2014, 21, 19–25. [Google Scholar]
- Levine, T.R.; Hullett, C.R. Eta Squared, Partial Eta Squared, and Misreporting of Effect Size in Communication Research. Hum. Commun. Res. 2002, 28, 612–625. [Google Scholar] [CrossRef]
- Cohen, J. Statistical Power Analysis for the Behavioral Sciences, 2nd ed.; Lawrence Erlbaum Associates: Hillsdale, NJ, USA, 1988. [Google Scholar]
- Efron, B.; Tibshirani, R. An Introduction to the Bootstrap; Chapman and Hall/CRC: Boca Raton, FL, USA, 1994. [Google Scholar] [CrossRef] [Scilit]
- Davison, A.; Hinkley, D. Bootstrap Methods and Their Application; Cambridge University Press: Cambridge, UK, 1997; Volume 94. [Google Scholar] [CrossRef] [Scilit]
- Bang, H.J.; Joachin, H.; Yang, H.; Amine, K.; Prakash, J. Contribution of the Structural Changes of LiNCA Cathodes on the Exothermic Reactions in Li-Ion Cells. J. Electrochem. Soc. 2006, 153, A731. [Google Scholar] [CrossRef] [Scilit]
- Bak, S.M.; Nam, K.W.; Chang, W.; Yu, X.; Hu, E.; Hwang, S.; Stach, E.A.; Kim, K.B.; Chung, K.Y.; Yang, X.Q. Correlating Structural Changes and Gas Evolution during the Thermal Decomposition of Charged LixNi0.8Co0.15Al0.05O2 Cathode Materials. Chem. Mater. 2013, 25, 337–351. [Google Scholar] [CrossRef] [Scilit]
- Bak, S.M.; Hu, E.; Zhou, Y.; Yu, X.; Senanayake, S.D.; Cho, S.J.; Kim, K.B.; Chung, K.Y.; Yang, X.Q.; Nam, K.W. Structural changes and thermal stability of charged LiNixMnyCozO2 cathode materials studied by combined in situ time-resolved XRD and mass spectroscopy. ACS Appl. Mater. Interfaces 2014, 6, 22594–22601. [Google Scholar] [CrossRef] [Scilit]
- Li, Y.; Liu, X.; Wang, L.; Feng, X.; Ren, D.; Wu, Y.; Xu, G.; Lu, L.; Hou, J.; Zhang, W.; et al. Thermal runaway mechanism of lithium-ion battery with LiNi0.8Mn0.1Co0.1O2 cathode materials. Nano Energy 2021, 85, 105878. [Google Scholar] [CrossRef] [Scilit]
- Liu, X.; Ren, D.; Hsu, H.; Feng, X.; Xu, G.L.; Zhuang, M.; Gao, H.; Lu, L.; Han, X.; Chu, Z.; et al. Thermal Runaway of Lithium-Ion Batteries without Internal Short Circuit. Joule 2018, 2, 2047–2064. [Google Scholar] [CrossRef] [Scilit]
- Finegan, D.; Darcy, E.; Keyser, M.; Tjaden, B.; Heenan, T.; Jervis, R.; Bailey, J.; Malik, R.; Vo, N.T.; Magdysyuk, O.; et al. Characterising thermal runaway within lithium-ion cells by inducing and monitoring internal short circuits. Energy Environ. Sci. 2017, 10, 1377–1388. [Google Scholar] [CrossRef] [Scilit]
- Finegan, D.; Darst, J.; Walker, W.; Li, Q.; Yang, C.; Jervis, R.; Heenan, T.; Hack, J.; Thomas, J.; Rack, A.; et al. Modelling and Experiments to Identify High-Risk Failure Scenarios for Testing the Safety of Lithium-ion Cells. J. Power Sources 2019, 417, 29–41. [Google Scholar] [CrossRef] [Scilit]
- Zou, K.; Chen, X.; Ding, Z.; Gu, J.; Lu, S. Jet behavior of prismatic lithium-ion batteries during thermal runaway. Appl. Therm. Eng. 2020, 179, 115745. [Google Scholar] [CrossRef] [Scilit]
- Li, W.; Crompton, K.R.; Hacker, C.; Ostanek, J.K. Comparison of Current Interrupt Device and Vent Design for 18650 Format Lithium-ion Battery Caps. J. Energy Storage 2020, 32, 101890. [Google Scholar] [CrossRef] [Scilit]
- Finegan, D.P.; Scheel, M.; Robinson, J.B.; Tjaden, B.; Hunt, I.A.; Mason, T.J.; Millichamp, J.; Michiel, M.D.; Offer, G.J.; Hinds, G.; et al. In-operando high-speed tomography of lithium-ion batteries during thermal runaway. Nat. Commun. 2015, 6, 6924. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Coman, P.; Matefi-Tempfli, S.; Veje, C.; White, R. Modeling Vaporization, Gas Generation and Venting in Li-Ion Battery Cells with a Dimethyl Carbonate Electrolyte. J. Electrochem. Soc. 2017, 164, A1858–A1865. [Google Scholar] [CrossRef] [Scilit]
- Willstrand, O.; Pushp, M.; Andersson, P.; Brandell, D. Impact of different Li-ion cell test conditions on thermal runaway characteristics and gas release measurements. J. Energy Storage 2023, 68, 107785. [Google Scholar] [CrossRef] [Scilit]
- Kong, D.; Wang, G.; Ping, P.; Wen, J. Numerical investigation of thermal runaway behavior of lithium-ion batteries with different battery materials and heating conditions. Appl. Therm. Eng. 2021, 189, 116661. [Google Scholar] [CrossRef] [Scilit]
- Wu, T.; Chen, H.; Wang, Q.; Sun, J. Comparison analysis on the thermal runaway of lithium-ion battery under two heating modes. J. Hazard. Mater. 2018, 344, 733–741. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Doose, S.; Hahn, A.; Bredekamp, M.; Haselrieder, W.; Kwade, A. Scaling methodology to describe the capacity dependent responses during thermal runaway of lithium ion batteries. Batter. Supercaps 2022, 5, e202200060. [Google Scholar] [CrossRef] [Scilit]
- Essl, C.; Golubkov, A.W.; Fuchs, A. Influence of Aging on the Failing Behavior of Automotive Lithium-Ion Batteries. Batteries 2021, 7, 23. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.