Reviewer 1 Report
Comments and Suggestions for AuthorsTitle:
The title of the manuscript does not adequately reflect the methodological design of the reliability study. In particular, it is not specified whether it is a test-retest, intra-evaluator or inter-evaluator reliability study. This omission reduces the scientific accuracy of the title and can lead to ambiguous interpretations. It is recommended to explicitly include the type of reliability evaluated, the study design and the target population.
Abstract:
The summary presents relevant methodological deficiencies. The type of intraclass correlation coefficient (CCI) used is not specified, which is critical, since different models (ICC(1,1), ICC(2,1), ICC(3,k), etc.) involve different assumptions and are not interchangeable. In addition, no 95% confidence intervals are reported, which prevents the evaluation of the accuracy of the estimates. Likewise, reliability analysis is limited to point ICC values without considering absolute error measures such as standard measurement error (SEM) or minimum detectable change (MDC), which represents an important methodological limitation. The interpretation through terms such as "good" or "excellent" reliability lacks explicit justification and is not clinically contextualized.
Introduction:
The introduction does not adequately develop the conceptual framework of the reliability studies. There is a lack of clear differentiation between fundamental concepts such as reliability, validity and agreement, which generates theoretical ambiguity. In addition, no reference is made to widely accepted international standards, such as the COSMIN guides for measurement property studies. It is recommended to strengthen the theoretical framework by including clear operational definitions and key methodological references.
Methods:
- The design of the studio is not described with sufficient precision. It is not clear whether it is a test-retest, intra-evaluator or inter-evaluator reliability study, which is essential for selecting the appropriate statistical model. Likewise, the time interval between measurements is not justified. In test-retest studies, it is essential to ensure that the measured construct remains stable between evaluations; otherwise, the reliability estimate may be compromised. This lack of justification represents a critical limitation.
- The manuscript does not include a specific sample size justification for reliability studies. No calculation is reported based on parameters such as the expected ICC, the desired level of accuracy or the statistical power.
- This omission is methodologically relevant, since inadequate sample sizes can produce unstable or biased estimates of the ICC. It is recommended to use specific methods to justify sample size.
- The description of the protocol is insufficient in terms of standardization. The training of the evaluators or the procedures used to minimize the variability between measurements are not adequately detailed. It is also not reported whether the evaluators were blinded to previous measurements, which is essential to avoid bias. In addition, possible learning or fatigue effects, which can significantly influence test-retest studies, are not considered.
- Nor is an agreement analysis carried out using methods such as Bland-Altman, which prevents the evaluation of systematic biases and agreement limits. The absence of Bland-Altman graphs prevents visually evaluating the agreement between measurements.
Discussion:
- The discussion presents an overinterpretation of the results. It is concluded that the tool has high reliability based only on the ICC, without considering the measurement error or its clinical relevance.
- In addition, possible mechanisms that explain the observed variability are not discussed, nor is it addressed whether the level of error is clinically acceptable.
Conclusion:
In addition, possible mechanisms that explain the observed variability are not discussed, nor is it addressed whether the level of error is clinically acceptable.
Author Response
Please find the revised manuscript (ISSN 2813-0413) entitled, “Intra- and Inter-Rater Reliability and Development of Normative Data for a Hip Proprioceptive Test in Healthy Adults” submitted for publication in Muscles.
First, we would like to thank both reviewers for their insightful comments and constructive criticism, which provided us with valuable direction. Based on their feedback, we reviewed several new publications that contributed to an improved manuscript. We appreciate this process and believe that the reviewers' comments have positively influenced this revised version. We trust that both reviewers will now be able to clearly observe the influence of their feedback on the revised manuscript. In the following sections, we provide a detailed summary of the changes made in response to each of the reviewers' comments.
Responses to Reviewers’ Comments:
|
Reviewer #1: Title: |
|
Author Response: We thank the reviewer for this constructive remark. We fully agree that the original title lacked the methodological precision recommended by the GRRAS guidelines (Kottner et al., J Clin Epidemiol 2011;64:96–106) and the COSMIN reporting standards (Mokkink et al., Qual Life Res 2018;27:1171–1179) for reliability studies. The title has been revised to explicitly specify (i) the three reliability dimensions evaluated (intra-rater, inter-rater, and test-retest) (ii) the two-phase study design, (iii) the measurement instruments (laser pointer and digital inclinometer) (iv) the target population (healthy adults). Action taken: The title has been changed (page 1) to : “Intra-Rater, Inter-Rater, and Test-Retest Reliability of a Laser- and Inclinometer-Based Hip Joint Position Sense Test in Healthy Adults: A Two-Phase Study with Normative Data” (lines 2-4) |
|
The summary presents relevant methodological deficiencies. The type of intraclass correlation coefficient (CCI) used is not specified, which is critical, since different models (ICC(1,1), ICC(2,1), ICC(3,k), etc.) involve different assumptions and are not interchangeable. In addition, no 95% confidence intervals are reported, which prevents the evaluation of the accuracy of the estimates. Likewise, reliability analysis is limited to point ICC values without considering absolute error measures such as standard measurement error (SEM) or minimum detectable change (MDC), which represents an important methodological limitation. The interpretation through terms such as "good" or "excellent" reliability lacks explicit justification and is not clinically contextualized. |
|
Author Response: We fully agree with the reviewer's comments. These four observations are highly relevant, and we sincerely thank the reviewer for highlighting these methodological shortcomings of the abstract. We acknowledge that, although all the requested information was already reported in the Statistical analysis section (§2.7.4), the abstract did not adequately reflect the methodological rigor of the analyses. The abstract has therefore been substantially revised to address every point raised. The following modifications were implemented in the revised manuscript: (i) Specification of the ICC model (lines 24–28). The abstract now explicitly states that ICCs were computed using two-way random-effects models with absolute agreement, specifying ICC(3,1) for intra-rater and ICC(2,1) for inter-rater analyses. (ii) Addition of 95% confidence intervals (lines 31–33). All ICC point estimates reported in the abstract are now systematically accompanied by their 95% confidence intervals: ICC = 0.64 (95% CI [0.39; 0.80]) for intra-rater medial rotation (line 31), and ICC = 0.78 (95% CI [0.50; 0.91]) for inter-rater medial rotation (lines 32–33). (iii) Integration of absolute error measures (lines 28–30 and 34–35). The abstract now explicitly reports SEM% and 95% MDC (MDC95%) as primary outcomes alongside the ICC, normalized to the target amplitudes to allow direct cross-direction comparison (lines 28–30). The trial-to-trial variability is now quantified through the MDC% (9–31%) for rotational movements (lines 34–35). (iv) Justification and clinical contextualization of qualitative thresholds (lines 26–28 and 36–38). The interpretation thresholds for the ICC are: poor (<0.50), moderate (0.50–0.70), good (≥0.70) (lines 26–28). A clinical interpretation of the SEM% has also been added to the concluding sentence: "the protocol achieved clinically acceptable measurement precision (SEM% < 10%) for rotational tasks" (lines 36–38). We believe that these modifications fully address the four methodological deficiencies identified by the reviewer and significantly enhance the methodological transparency of the abstract, in line with COSMIN and GRRAS reporting standards. Action taken: Abstract revised on page 1, lines 16–38 (revised manuscript). The corresponding tracked changes are highlighted in yellow in the marked-up version of the manuscript.
|
|
The introduction does not adequately develop the conceptual framework of the reliability studies. There is a lack of clear differentiation between fundamental concepts such as reliability, validity and agreement, which generates theoretical ambiguity. In addition, no reference is made to widely accepted international standards, such as the COSMIN guides for measurement property studies. It is recommended to strengthen the theoretical framework by including clear operational definitions and key methodological references. |
|
Author Response: We fully agree with the reviewer's comment and sincerely thank the reviewer for this constructive observation. We acknowledge that, despite the methodological rigor applied throughout the study (a COSMIN- and GRRAS-compliant design, combined relative and absolute reliability indices, Bland–Altman agreement assessment), the original Introduction did not explicitly anchor the study within the internationally accepted clinimetric framework, nor did it provide operational definitions of the core measurement properties. This omission has been fully corrected in the revised manuscript. Action taken: A new conceptual paragraph has been added to the Introduction (page 1, lines 70–83, revised manuscript): “According to the COSMIN initiative (COnsensus-based Standards for the selection of health Measurement INstruments) and the GRRAS guidelines, the appraisal of measurement properties requires a clear distinction between reliability, measurement error, and validity [22,23]. Reliability is defined as the proportion of the total variance in the measurements that is due to true differences between subjects, and is typically quantified by the intraclass correlation coefficient (ICC). Measurement error refers to the systematic and random error of a patient's score that is not attributed to true changes in the construct to be measured, and is evaluated through the standard error of measurement (SEM) and the minimal detectable change (MDC) [24]. Validity, by contrast, denotes the degree to which an instrument measures the construct it purports to assess [22]. These complementary but methodologically distinct properties require a rigorous clinimetric appraisal, combining relative (ICC) and absolute (SEM, MDC) indices, before any clinical use of a new assessment tool [22]”. “The primary aim of this two-phase study was to evaluate the intra-rater, inter-rater, and test-retest reliability of a standardized laser- and inclinometer-based protocol for assessing hip joint position error”. |
|
Method: 1. The design of the studio is not described with sufficient precision. It is not clear whether it is a test-retest, intra-evaluator or inter-evaluator reliability study, which is essential for selecting the appropriate statistical model. 2. Likewise, the time interval between measurements is not justified. In test-retest studies, it is essential to ensure that the measured construct remains stable between evaluations; otherwise, the reliability estimate may be compromised. This lack of justification represents a critical limitation. 3. The manuscript does not include a specific sample size justification for reliability studies. No calculation is reported based on parameters such as the expected ICC, the desired level of accuracy or the statistical power. This omission is methodologically relevant, since inadequate sample sizes can produce unstable or biased estimates of the ICC. It is recommended to use specific methods to justify sample size. 4. The description of the protocol is insufficient in terms of standardization. The training of the evaluators or the procedures used to minimize the variability between measurements are not adequately detailed. It is also not reported whether the evaluators were blinded to previous measurements, which is essential to avoid bias. In addition, possible learning or fatigue effects, which can significantly influence test-retest studies, are not considered. 5. Nor is an agreement analysis carried out using methods such as Bland-Altman, which prevents the evaluation of systematic biases and agreement limits. The absence of Bland-Altman graphs prevents visually evaluating the agreement between measurements. |
|
Author Response: We sincerely thank Reviewer for this thorough and detailed evaluation of the Methods section. We have implemented coordinated revisions to address each of the seven specific points raised. The modifications are presented below in the order of the reviewer's comments. All changes are highlighted in yellow in the marked-up version of the manuscript. Reviewer's concern: "It is not clear whether it is a test-retest, intra-evaluator or inter-evaluator reliability study." We fully agree with the reviewer. Action taken — §2.7.4 (Reliability analysis): "Three distinct types of reliability were evaluated, in line with COSMIN terminology [22]: (i) intra-session reliability (consistency of three repeated measurements within the same session, ICC(3,1)); (ii) test-retest reliability (stability of measurements performed by the same rater across two sessions separated by 24 hours, ICC(3,1)); and (iii) inter-rater reliability (agreement between two raters assessing the same participants, ICC(2,1)). All ICCs were computed using two-way random-effects models with absolute agreement, following Shrout and Fleiss (1979) and Koo and Li (2016)."
Reviewer's concern: "The time interval between measurements is not justified… it is essential to ensure that the measured construct remains stable between evaluations." Action taken — §2.3 (Testing Sessions): "The 24-hour interval was selected to minimize potential fatigue effects induced by testing while ensuring stability of the proprioceptive construct between assessments [25]." Action taken — §2.5 (Randomisation and repetitions): "Each movement direction was repeated three times, with a 15-second rest period between repetitions and movements. A 3-minute rest period was implemented when changing laterality and prior to the assessment of medial and lateral rotations. In addition, a standardized 10-minute seated rest period was implemented between reassessments during room transitions." Reviewer's concern: "The manuscript does not include a specific sample size justification… No calculation is reported based on parameters such as the expected ICC, the desired level of accuracy or the statistical power." Action taken — §2.7.1 (Sample size calculation): "For reliability analyses, the required sample size was calculated in accordance with COSMIN recommendations [26]. Assuming an expected ICC of ρ₁ = 0.70 ("good" reliability) tested against a null hypothesis of ρ₀ = 0.50 ("moderate" reliability), with k = 2 ratings per participant, α = 0.05, and a statistical power of 1−β = 0.80, the required sample size was estimated at approximately 46–50 participants [27]. For measurement error analyses (SEM, MDC, and Bland–Altman agreement), the COSMIN Risk of Bias Checklist recommends a minimum sample size of n ≥ 50. Accordingly, Phase 2 included 56 participants, ensuring acceptable methodological quality for both reliability and measurement error analyses. Phase 1 included 17 participants as an exploratory reliability sub-analysis intended to provide preliminary ICC estimates prior to confirmatory testing in Phase 2 [27,28]. Intra-session analyses additionally included k = 3 repeated measurements per participant, further reducing the confidence intervals of intra-session ICC estimates [27]." Reviewer's concern: "The training of the evaluators or the procedures used to minimize the variability between measurements are not adequately detailed." Action taken — New §2.3.1 (Rater training and standardisation): "All raters (one experienced and three novice raters) participated in a single 2-hour standardized training session covering all testing positions, procedures, instrumentation (laser pointer alignment and inclinometer placement), and standardized verbal instructions. Following this training, each rater performed four pilot assessments on volunteers external to the study sample in order to stabilize the procedure and achieve an operator reliability plateau prior to data collection. A written standardized operating procedure was followed by all raters throughout the study [22,23]." Reviewer's concern: "It is also not reported whether the evaluators were blinded to previous measurements, which is essential to avoid bias." Action taken — §2.3 (Testing Sessions): "To prevent any anchoring or expectation bias, raters were systematically blinded to all previous measurements: (i) within a session, the co-rater recorded the values on a separate datasheet not visible to the primary rater; (ii) between Session 1 and Session 2, the rater performing Session 2 had no access to the Session 1 values of the same participant; and (iii) in inter-rater assessments, neither rater had access to the other rater's values. All data were entered into a secured digital database and unblinded only at the end of data collection." Reviewer's concern: "Possible learning or fatigue effects, which can significantly influence test-retest studies, are not considered." Action taken — §2.4 (Testing procedure): "Several procedural choices were implemented to minimize potential learning and fatigue effects [24]: (i) one standardized familiarization trial was performed for each movement direction prior to the recorded measurements; (ii) the knee remained flexed throughout most assessments to limit muscular fatigue; (iii) the randomized order of movement directions ensured an equal distribution of any residual learning or fatigue effects across conditions; and (iv) the duration of each session was limited to a maximum of 15 minutes."
Reviewer's concern: "Nor is an agreement analysis carried out using methods such as Bland-Altman, which prevents the evaluation of systematic biases and agreement limits. The absence of Bland-Altman graphs prevents visually evaluating the agreement between measurements." We thank the reviewer for this constructive comment. We fully agree that a Bland–Altman analysis is essential to visually evaluate systematic biases and limits of agreement between measurements, in line with the recommendations of Bland & Altman (1986, 1999, 2010), Giavarina (2015, Biochem Med), Gerke (2020, Diagnostics), and CLSI EP09-A3. In response, we have added a new Supplementary Appendix BA.
We sincerely apologize if the visibility of this analysis was insufficient in the original manuscript. |
|
Discussion: · The discussion presents an overinterpretation of the results. It is concluded that the tool has high reliability based only on the ICC, without considering the measurement error or its clinical relevance.
|
|
Author Response: We sincerely thank Reviewer for this constructive and methodologically pertinent comment. We acknowledge that the original Discussion did not sufficiently combine the relative (ICC) and absolute (SEM%, MDC%) reliability indices, and that the mechanisms underlying the observed variability and their clinical implications were not made explicit. The Discussion has been substantially revised to address both concerns. Three coordinated modifications have been implemented, summarized below in their order of appearance in the manuscript. All changes are highlighted in yellow in the marked-up version of the manuscript. Reviewer's concern addressed: terminological consistency between title, aims, and Discussion Action taken — §5 Discussion (opening sentence): "The primary objective of this two-phase study was to evaluate the intra-rater, inter-rater, and test-retest reliability of a standardized laser- and inclinometer-based protocol for measuring hip joint position error and to establish normative values in healthy adults." Reviewer's concern addressed: "The discussion presents an overinterpretation of the results. It is concluded that the tool has high reliability based only on the ICC, without considering the measurement error or its clinical relevance." Action taken — §5 Discussion (first paragraph): "Intra-rater reliability ranged from poor to moderate across movement directions (ICC = 0.00–0.64), with consistently higher values for experienced raters than for novice raters and a clear trend toward better reliability for movements involving small amplitudes and proximal control. Inter-rater reliability was overall low and heterogeneous across directions (ICC = 0.01–0.78), but showed a marked improvement between Session 1 and Session 2, suggesting a learning effect inherent to the proprioceptive task and to rater–participant interaction. Among all assessed directions, medial and lateral rotations consistently appeared to be the most clinically informative: medial rotation demonstrated the highest inter-rater reliability (ICC = 0.78; 95% CI [0.50–0.91]), and both rotational movements showed the lowest SEM% values (3–6 %, within clinically acceptable limits), together with the lowest normative repositioning errors (2.28° ± 1.95° for medial rotation; 2.22° ± 2.02° for lateral rotation)." Reviewer's concern addressed: "Possible mechanisms that explain the observed variability are not discussed, nor is it addressed whether the level of error is clinically acceptable." Action taken — §4.3 (Overall reflection on the contrast between ICC, SEM%, and MDC%): "The combination of a low SEM% and a high MDC% suggests good measurement precision but limited trial-to-trial stability [36], a pattern frequently reported in proprioceptive assessments and reflecting known methodological limitations of joint position sense (JPS) and threshold to detect passive motion (TTDPM) tests [30,37]. This dissociation between average precision and consistency likely reflects four converging sources of variability: (i) participant-level stochastic fluctuations along the neuromuscular pathway, from action potential generation to neuromuscular transmission and muscle fiber activation [25,38]; (ii) task-level multisegmental compensations during large-amplitude movements (flexion, abduction), which amplify laser-derived linear errors [39]; (iii) rater-level experience effects, with experienced raters reaching ICC up to 0.64 vs. < 0.30 in novice raters, consistent with previous lower-limb JPS data [30]; and (iv) tool-level robustness, with inclinometer-based angular measures (rotations) being less affected than laser-derived linear errors amplified by target distance. In our joint position reproduction protocol, the trial-to-trial variability likely reflects this fundamental sensorimotor uncertainty, largely independent of the mean task precision. From a clinical standpoint, these findings suggest that performing a same-session test–retest in rotational positions with an inclinometer, which showed the lowest measurement error, may be the most effective approach to detect changes exceeding the MDC% and to identify potential 'good responders'. Considered jointly with their clinical interpretation, the SEM% values observed for rotational movements (3–6 %) fall well within the threshold considered clinically acceptable for proprioceptive assessment tools (SEM% < 10 %) [24], supporting the suitability of these directions for clinical use. Conversely, the MDC% values observed for sagittal and frontal-plane movements (frequently > 30 %) exceed the threshold of clinically interpretable change [24], suggesting that these directions, in their current measurement form, may not be suitable for detecting individual within-subject changes in clinical practice." |
|
Conclusion |
|
Author Response: We sincerely thank Reviewer for this constructive comment. Action taken — §5 Conclusion (opening sentence): "The primary objective of this two-phase study was to evaluate the intra-rater, inter-rater, and test-retest reliability of a standardized laser- and inclinometer-based protocol for measuring hip joint position error and to establish normative values in healthy adults." Action taken — §5 Conclusions, lines 486–494: “The results demonstrated satisfactory measurement precision (low SEM%) but overall low to moderate relative reliability (ICC = 0.00–0.78), influenced by rater experience, movement direction, and the inherent fluctuations of sensorimotor control. Medial and lateral rotations showed the most favourable trade-off between relative reliability and absolute measurement error (SEM% = 3–6 %, within clinically acceptable limits), supporting their potential clinical relevance for individual-level hip proprioceptive monitoring”. |
Author Response File:
Author Response.pdf
Reviewer 2 Report
Comments and Suggestions for AuthorsThe manuscript has a relevant topic, but it needs major revision. The main problem is that the results are weak, but the manuscript makes too strong statements. The protocol is described as useful and as having “acceptable precision” but many ICC values are poor. The conclusion should be more careful. Rotation measurements with the inclinometer seem more promising, but the full protocol is still exploratory and not ready for clinical use.
There is also a major problem with the sample size in Phase 1. The manuscript says that 25-50 participants are needed for good precision but only 17 were included. This must be explained or added as a major limitation. The term “normative data” is too strong. A sample of 56 healthy participants, probably young and active, cannot create true normative values for the general population. The authors should call them “preliminary reference values” instead. Repeated trials should not be counted as independent data. The authors should calculate one mean value for each participant, then report the reference values based on 56 participant means.
The ICC methods need correction. The methods say that ICC(2,1) was used for inter-rater reliability, but one appendix reports ICC(3,1). The tables and methods must match. The Bland-Altman table also seems to contain an error for lateral rotation, where the lower and upper limits are identical.
The manuscript should explain why Phase 2 used two novice raters. It should also discuss that laser based distance measurements and inclinometer based angle measurements are different so they cannot be compared directly.
The Discussion should be shorter and should not repeat many numbers from the Results.
The authors should fix section numbering and use the same terms throughout the paper
Finally, the manuscript should state that the protocol measures active repositioning performance, not proprioception. Clinical claims about patient stratification, treatment progress, or rehabilitation monitoring need further studies in symptomatic patients.
Author Response
Please find the revised manuscript (ISSN 2813-0413) entitled, “Intra- and Inter-Rater Reliability and Development of Normative Data for a Hip Proprioceptive Test in Healthy Adults” submitted for publication in Muscles.
First, we would like to thank both reviewers for their insightful comments and constructive criticism, which provided us with valuable direction. Based on their feedback, we reviewed several new publications that contributed to an improved manuscript. We appreciate this process and believe that the reviewers' comments have positively influenced this revised version. We trust that both reviewers will now be able to clearly observe the influence of their feedback on the revised manuscript. In the following sections, we provide a detailed summary of the changes made in response to each of the reviewers' comments.
Responses to Reviewers’ Comments:
|
Reviewer: The manuscript has a relevant topic, but it needs major revision. The main problem is that the results are weak, but the manuscript makes too strong statements. The protocol is described as useful and as having “acceptable precision” but many ICC values are poor. The conclusion should be more careful. Rotation measurements with the inclinometer seem more promising, but the full protocol is still exploratory and not ready for clinical use. |
|
Author Response: We sincerely thank Reviewer for this very pertinent and constructive comment. We fully agree. Action taken — Abstract, lines 37–39: The final sentences of the Abstract have been reformulated to explicitly state that only the rotational tasks reached clinically acceptable precision, that the laser-based components remained exploratory, and that the protocol requires further validation before clinical use. "Despite overall low-to-moderate reliability, the protocol achieved clinically acceptable measurement precision (SEM% < 10%) for rotational tasks, whereas the laser-based sagittal and frontal-plane components remained exploratory. The protocol provides preliminary reference values for hip JPS in healthy adults and requires further validation before clinical use."
The opening paragraph of the Discussion has been reformulated to (i) report the full dispersion of ICC values (range 0.00–0.64 for intra-rater and 0.01–0.78 for inter-rater reliability), (ii) explicitly mention the heterogeneity across directions, and (iii) integrate the joint interpretation of ICC, SEM%, and normative values rather than relying on ICC alone. Action taken — Discussion, first paragraph, lines 394–405: "Intra-rater reliability ranged from poor to moderate across movement directions (ICC = 0.00–0.64), with consistently higher values for experienced raters than for novice raters and a clear trend toward better reliability for movements involving small amplitudes and proximal control. Inter-rater reliability was overall low and heterogeneous across directions (ICC = 0.01–0.78), but showed a marked improvement between Session 1 and Session 2, suggesting a learning effect inherent to the proprioceptive task and to rater–participant interaction. Among all assessed directions, medial and lateral rotations consistently appeared to be the most clinically informative: medial rotation demonstrated the highest inter-rater reliability (ICC = 0.78; 95% CI [0.50–0.91]), and both rotational movements showed the lowest SEM% values (3–6%, within clinically acceptable limits), together with the lowest normative repositioning errors (2.28° ± 1.95° for medial rotation; 2.22° ± 2.02° for lateral rotation)."
The closing clinical interpretation of §4.3 has been substantially moderated to avoid suggesting immediate clinical suitability of the rotational tasks. The previous wording "supporting the suitability of these directions for clinical use" has been replaced by "identifying these directions as the most promising candidates for further clinimetric validation". The exploratory nature of the laser-based components has been preserved and clarified. Action taken — §4.3, lines 455–459: "…the SEM% values observed for rotational movements (3–6 %) fall well within the threshold considered clinically acceptable for proprioceptive assessment tools (SEM% < 10 %) [24], identifying these directions as the most promising candidates for further clinimetric validation. Conversely, the MDC% values observed for sagittal and frontal-plane movements (frequently > 30 %) exceed the threshold of clinically interpretable change [24], suggesting that these directions, in their current measurement form, may not be suitable for detecting individual within-subject changes in clinical practice."
The Conclusion has been revised to (i) report the full dispersion of ICC values (range 0.00–0.78), (ii) explicitly acknowledge the mechanisms of observed variability (rater experience, movement direction, and inherent sensorimotor fluctuations), (iii) frame the rotational findings as "potential clinical relevance" rather than "highest precision supporting clinical relevance", and (iv) explicitly distinguish the rotational components from the rest of the protocol. Action taken — §5 Conclusion, lines 488–496: "The results demonstrated satisfactory measurement precision (low SEM%) but overall low to moderate relative reliability (ICC = 0.00–0.78), influenced by rater experience, movement direction, and the inherent fluctuations of sensorimotor control. Medial and lateral rotations showed the most favourable trade-off between relative reliability and absolute measurement error (SEM% = 3–6 %, within clinically acceptable limits), supporting their potential clinical relevance for individual-level hip proprioceptive monitoring." |
|
There is also a major problem with the sample size in Phase 1. The manuscript says that 25-50 participants are needed for good precision but only 17 were included. This must be explained or added as a major limitation. The term “normative data” is too strong. A sample of 56 healthy participants, probably young and active, cannot create true normative values for the general population. The authors should call them “preliminary reference values” instead. |
|
Author Response: We sincerely thank Reviewer 2 for these two pertinent observations, which substantially improve both the methodological transparency and the terminological accuracy of the manuscript. We fully agree on both points and have implemented coordinated modifications across the manuscript. All changes are highlighted in yellow in the marked-up version. Point 1 — Sample size of Phase 1 (n = 17) explicitly framed as an exploratory limitation We fully agree with the reviewer that the Phase 1 sample size requires an explicit and transparent justification. The Methods section (§2.7.1, Sample size calculation) has been rewritten to explicitly position Phase 1 as an exploratory reliability sub-analysis preceding the confirmatory testing performed in Phase 2 (n = 56), in line with the precision-based methodology recommended by Bonett (2002) and Walter et al. (1998), and endorsed by the COSMIN initiative. Action taken — §2.7.1 Sample size calculation, lines [222]: "…Phase 1 included 17 participants as an exploratory reliability sub-analysis intended to provide preliminary ICC estimates prior to confirmatory testing in Phase 2 [27,28]." This formulation makes explicit that (i) Phase 1 was not designed as a confirmatory analysis with the precision targeted by the Bonett/Walter sample size calculation, and that (ii) its purpose was to provide preliminary ICC estimates before the confirmatory testing performed in Phase 2 (n = 56). The wide confidence intervals reported in Phase 1 are consequently expected and transparently reported. Point 2 — Systematic terminological revision: "normative data" → "preliminary reference values" We fully agree with the reviewer that a sample of 56 healthy adults, given its demographic profile, cannot be considered as constituting normative values for the general adult population. The terminology was indeed too strong and has been systematically replaced by "preliminary reference values" throughout the manuscript, in accordance with the reviewer's recommendation. Action taken — Systematic terminological revision across the entire manuscript: The revised manuscript title is now: "Intra-Rater, Inter-Rater, and Test-Retest Reliability of a Laser- and Inclinometer-Based Hip Joint Position Sense Test in Healthy Adults: A Two-Phase Study with Preliminary Reference Values" The terminological replacement has been applied consistently across the Abstract, Introduction (objectives), Methods, Results, Discussion, and Conclusion, including the titles of subsections (§3.5 Preliminary reference values in a healthy population; §4.4 Preliminary reference values). The revised wording explicitly reflects the preliminary, sample-specific nature of the values reported and avoids any implication of population-level normativity. Future studies in larger and demographically more diverse samples will be required to establish true normative values, a point now explicitly acknowledged. |
|
The authors should calculate one mean value for each participant, then report the reference values based on 56 participant means. |
|
Author Response: We thank the reviewer for this important methodological remark, with which we fully agree. The original pooling of repeated trials violated the independence-of-observations assumption that underpins parametric descriptive statistics: repeated measurements collected on the same participant are correlated, and pooling inflates the standard deviation (by conflating inter-individual variability with intra-trial fluctuations) and artificially narrows the standard error of the mean. We have therefore recomputed all preliminary reference values as follows:
Changes in the Methods (Section 2.7). The following sentence has replaced the previous description of the pooling approach: "Preliminary reference values were derived by first computing, for each participant and each movement direction, the mean repositioning error from the available trials (12 trials = 3 repetitions × 2 sides × 2 raters; 6 trials when data from only one rater were available). Descriptive statistics (mean, standard deviation, 95% confidence interval, median, first and third quartiles, interquartile range, skewness, and Shapiro–Wilk test for normality) were then computed across the n = 57 participants. This participant-level approach preserves the independence-of-observations assumption and reflects inter-individual variability only, rather than pooling intra-trial fluctuations." Changes in the Results (Section 3.4 and Table 5). All reference values reported in Table 5 have been recomputed accordingly. The means are essentially unchanged (the operation is mathematically equivalent at the central-tendency level), whereas the standard deviations are markedly smaller because they now reflect inter-individual variability only (e.g. flexion: 21.45 ± 14.10 cm → 21.06 ± 5.96 cm; adduction: 5.25 ± 3.82 cm → 5.53 ± 2.25 cm). Median, Q1, Q3 and Shapiro–Wilk p values have been added. Changes in Figure 2 (p. X). Figure 2 has been entirely redrawn to reflect the revised analysis. It now combines four panels: (a) a wall view of the laser projection (sagittal and frontal planes) with the four anterior targets drawn to scale, surrounded by ±1 SD bands, 95% CI bands and individual participant means; (b) a rotational dial of the inclinometer (transverse plane) showing the two angular targets (+ 15° and − 30°) and the corresponding individual scatter; (c) violin plots with embedded boxplots and jittered individual means for the four linear movements (cm); and (d) the same graphical conventions for the two rotational movements (°). The legend explicitly mentions that each data point represents one participant's mean computed from up to 12 trials. We thank the reviewer once again for this insightful comment, which has clearly strengthened the methodological rigor and the clinical interpretability of our reference values.
|
|
The ICC methods need correction. The methods say that ICC(2,1) was used for inter-rater reliability, but one appendix reports ICC(3,1). The tables and methods must match. The Bland-Altman table also seems to contain an error for lateral rotation, where the lower and upper limits are identical. |
|||||||||
|
Author Response: We sincerely thank Reviewer for this careful methodological audit. · We confirm that the reviewer is correct. The Methods section (§2.7.4) explicitly stated that the ICC(2,1) model (two-way random-effects with absolute agreement, single rater) was used for inter-rater reliability analyses). The column header of Appendix F erroneously read "ICC(3,1)", which was a labelling inconsistency. After verification of the original JASP analyses (version 0.17.2.1), we confirm that the analyses were correctly performed using the option "a different rater (randomly selected)", which corresponds to the ICC(2,1) model. The numerical values reported in Appendix F are therefore correct; only the column header needed to be corrected. Action taken — Appendix F (and Appendix 6 in Tables.docx), column headers (Sessions 1 and 2): "ICC(3,1) [IC95%]" → "ICC(2,1) [95% CI]"
· We confirm that the reviewer is absolutely correct. Upon careful verification, the Bland–Altman row for Lateral rotation in Table 4 (b) contained a typographical error: the Lower LOA cell mistakenly displayed the value of the Upper LOA (11.56 [8.96 ; 14.16]), resulting in identical Lower and Upper LOA cells. The error originated from an inadvertent duplication of the Upper LOA cell during table editing in Word. Using the published Mean bias (0.40) and SD of differences (5.69) of the differences for Lateral rotation, the correct Lower LOA is recalculated according to Bland and Altman (1986) as:
with its 95% CI computed as Lower LOA ± t·SE(LOA), where SE(LOA) = √(3·SD²/n). Action taken — Table 4 (b), Lateral rotation row, lines [372]:
|
|
The manuscript should explain why Phase 2 used two novice raters. It should also discuss that laser based distance measurements and inclinometer based angle measurements are different so they cannot be compared directly. |
|
Author Response: We sincerely thank Reviewer for these two pertinent comments. Point 1 — Rationale for the use of two novice raters in Phase 2 We agree with the reviewer that the original manuscript did not explicitly justify the choice of two novice raters in Phase 2. A clarifying sentence has been added to §2.3 (Testing Sessions), grounding this design choice in the principle of ecological validity (Mokkink et al., 2018 [22]): novice raters represent the most realistic profile of the future clinical users of the protocol, and testing reliability under such conditions provides a deliberately conservative ('worst-case') estimate of the protocol's performance at the time of its first clinical implementation. This rationale is further reinforced by the fact that both novice raters received a standardized 2-hour training and four pilot assessments (described in §2.3.1) to ensure their methodological equivalence at the time of testing. Action taken — §2.3 (Testing Sessions), line 133: "This design was chosen to objectify the reliability of the protocol under conditions corresponding to its first clinical use." Point 2 — Non-comparability of laser-based (cm) and inclinometer-based (°) measurements We fully agree with the reviewer's observation. The protocol combines two dimensionally distinct measurement systems — a laser pointer expressed in centimetres (for sagittal- and frontal-plane movements) and a digital inclinometer expressed in degrees (for rotational movements) — and absolute SEM and MDC values are therefore not directly comparable across modalities. The original manuscript implicitly addressed this issue by normalizing the SEM and MDC to their respective target amplitudes (SEM% and MDC%), but this methodological choice was not made sufficiently explicit. A clarifying sentence has been added to §4.5 (Strengths and limitations) to acknowledge this dimensional limitation and justify the use of normalized indices for cross-direction comparisons, in accordance with Atkinson and Nevill (1998) [29]. Action taken — §4.5 (Strengths and limitations), final paragraph: "Finally, laser-based linear measurements (cm) and inclinometer-based angular measurements (°) being dimensionally distinct, absolute SEM and MDC values are not directly comparable across modalities; cross-direction comparisons were therefore restricted to the normalized SEM% and MDC%." |
|
|
|
Author Response: We fully agree with the reviewer. The Discussion has been shortened by removing the numerical values that were already reported in the Results section and Tables, while preserving the interpretive content essential to the discussion of our findings. Four coordinated modifications have been implemented, summarized below. All changes are highlighted in yellow in the marked-up version of the manuscript.
Modification 1 — §5 Discussion (opening paragraph, line 250) — Removal of internal duplication The final sentence of the opening paragraph, which restated absolute reference values already presented in the preceding sentence and in Table 5, has been substantially shortened. Action taken — §5 Discussion, opening paragraph: Before: "Preliminary reference values showed larger reproduction errors in the sagittal and frontal planes (flexion: 21.45 cm; abduction: 7.33 cm; adduction: 5.25 cm; extension: 3.33 cm) and markedly smaller errors for rotations (2.28° medial; 2.22° lateral)." After: "Preliminary reference values showed larger reproduction errors in the sagittal and frontal planes and markedly smaller errors for rotations." Modification 2 — §5 Discussion (opening paragraph) — Removal of redundant inter-rater ICC values Numerical values reported in the inter-rater reliability sentence of the opening paragraph have been removed, as they are already fully reported in Tables 2–4. Action taken — §5 Discussion, opening paragraph (inter-rater sentence): The numerical ICC values for inter-rater reliability have been removed from the synthetic narrative, with the full numerical content now exclusively reported in Tables 2–4 and the Results section. Modification 3 — §4.3 Overall reflection — Removal of redundant SEM% values The numerical range "(3–6 %)" for the SEM% of rotational movements has been removed, as these values are already reported in Table 4. The clinical reference threshold (SEM% < 10 %) has been retained, as it constitutes an essential interpretive anchor. Action taken — §4.3 Overall reflection (clinical interpretation paragraph): Before: "…the SEM% values observed for rotational movements (3–6 %) fall well within the threshold considered clinically acceptable for proprioceptive assessment tools (SEM% < 10 %) [24]…" After: "…the SEM% values observed for rotational movements fall well within the threshold considered clinically acceptable for proprioceptive assessment tools (SEM% < 10 %) [24]…" Modification 4 — §4.4 Preliminary reference values — Synthetic reformulation The descriptive sentence on the hierarchy of variability has been reformulated to be more synthetic, fusing the description of the pattern and its mechanistic interpretation into a single, denser sentence. Action taken — §4.4 Preliminary reference values: After: "The hierarchy of variability, greater in the sagittal and frontal planes, smaller in rotational movements, likely reflects the combined contribution of pelvic compensations, the density of capsulolabral and muscle spindle inputs, and the measurement modality itself." |
|
The authors should fix section numbering and use the same terms throughout the paper |
|
Author Response: Modification 1 — Correction of the duplicate section number "5" The Discussion section was erroneously numbered "5" while its sub-sections were correctly labelled 4.1 to 4.5, and the Conclusions section was also numbered "5", resulting in a duplicate section number. The Discussion has been renumbered to "4" to ensure continuous and consistent section numbering throughout the manuscript. Action taken: "5. Discussion" → "4. Discussion" (Conclusions remain numbered "5. Conclusions") Modification 2 — Restoration of the missing section 3.3 in the Results The original numbering of the Results section skipped from 3.2 directly to 3.4, as the title of section 3.3 had been inadvertently embedded in the body text rather than displayed as a standalone heading. The section title has now been restored as a proper heading, and the subsequent sections have been renumbered accordingly to ensure continuous numbering (3.1 → 3.2 → 3.3 → 3.4). Action taken: Section 3.3 title restored as a standalone heading, with subsequent sub-sections renumbered accordingly. |
|
Finally, the manuscript should state that the protocol measures active repositioning performance, not proprioception. Clinical claims about patient stratification, treatment progress, or rehabilitation monitoring need further studies in symptomatic patients. |
|
Author Response: We sincerely thank Reviewer for this very important and methodologically rigorous comment. Modification 1 — Abstract: explicit mention of the "active" nature of the protocol The Abstract has been revised to explicitly state that the protocol assesses active joint position reproduction. Action taken — Abstract: "This study evaluated the intra- and inter-rater reliability of a laser- and inclinometer-based active hip JPS protocol and established preliminary reference values in healthy adults." Modification 2 — §4 Discussion (opening sentence): conceptual alignment The opening sentence of the Discussion has been revised to align with the explicit mention of the active nature of the measurement. Action taken — §4 Discussion, opening sentence: "The primary objective of this two-phase study was to evaluate the intra-rater, inter-rater, and test-retest reliability of a standardized laser- and inclinometer-based protocol for measuring active hip joint position error and to establish preliminary reference values in healthy adults." Modification 3 — §4.4 Preliminary reference values: moderation of the clinical claim The final sentence of §4.4 has been substantially moderated to make explicit that any clinical application would require further validation studies. Action taken — §4.4, last sentence: Before: "These preliminary reference values therefore provide not only reference thresholds but also a graded clinical framework to support patient stratification and therapeutic progression." After: "These preliminary reference values may provide an initial methodological basis for future research. However, any clinical application, such as patient stratification, rehabilitation monitoring, or evaluation of therapeutic progression, would require further validation studies." Modification 4 — §4.5 Strengths and limitations: existing acknowledgment of the active vs. pure proprioception distinction We respectfully draw the reviewer's attention to the fact that §4.5 already explicitly stated: "the exclusive use of active measurements, producing a composite assessment of proprioceptive and motor functions rather than isolated proprioception". This sentence has been preserved in the revised version, as it directly supports the reviewer's first concern regarding the composite nature of the measurement. Modification 5 — §5 Conclusions: final alignment of the take-home message The Conclusion has been revised to (i) explicitly state the active nature of the joint position reproduction performance measured, and (ii) frame the clinical perspective as a foundation for future studies in symptomatic populations. Action taken — §5 Conclusions: "This two-phase study aimed to evaluate the intra-rater, inter-rater, and test-retest reliability of a standardized laser- and inclinometer-based protocol for measuring active hip JPS, and to establish preliminary reference values in a healthy population. […] The preliminary reference values obtained provide an initial reference for the clinical interpretation of active hip JPS performance and lay the groundwork for future studies in symptomatic populations." |
Author Response File:
Author Response.pdf
Round 2
Reviewer 1 Report
Comments and Suggestions for AuthorsOk
Reviewer 2 Report
Comments and Suggestions for AuthorsMy comments and suggestions were addressed. The work is now ready to be published.