Abstract
We investigate the directed migration of weakly magnetic aqueous 4-hydroxy-TEMPO (TEMPOL) droplets immersed in diamagnetic phenylmethyl silicone oil. Gouy-balance measurements show an approximately linear concentration dependence of the dimensionless SI volume susceptibility of the solutions (). The fivefold-diluted solution has a measured susceptibility of and a positive susceptibility contrast of relative to the oil. Droplets of 1.0 and 2.0 µL traverse a interval toward the high-field region in 14.5 and , respectively. An analytical permanent-magnet field coupled to a spherical Stokes model is evaluated against 32 concentration–volume combinations. All calculations use the same inputs: silicone-oil kinematic viscosity , dynamic viscosity derived from the measured oil density, a fixed calculation height , and drag coefficient . The mean absolute percentage error is , the root-mean-square error is , and the Pearson correlation coefficient is 0.818. Concentration and volume trends support susceptibility-contrast-driven migration, while systematic residuals identify the limits of the common fixed-height, constant-drag model. The results demonstrate magnetic transport of weakly magnetic liquid droplets without added solid magnetic particles.
1. Introduction
The sensitivity of soft matter to external fields makes it an important platform for nonequilibrium physics and microfluidics. Electric, optical, acoustic, and magnetic fields provide different routes to actuation [1]. Magnetic fields penetrate most container walls and enable remote manipulation with limited Joule heating in weakly conducting samples [2,3]. Many liquids and biological materials are weakly paramagnetic or diamagnetic, with volume susceptibilities of order . Their manipulation therefore requires attention to both the field gradient and the magnetic properties of the surrounding medium.
Adding ferromagnetic or superparamagnetic particles enhances magnetic response, but also changes the composition of the target. The magneto-Archimedes effect provides an alternative based on susceptibility contrast. Strong-gradient fields have been used to levitate organic materials and water [4,5,6,7], and to separate particles according to density and susceptibility differences [8]. Related platforms enable label-free analysis and manipulation of weakly magnetic particles and liquids [9,10]. Ferrofluids and paramagnetic solutions have also been used as continuous phases for negative magnetophoresis [11,12,13,14] and for single-cell density characterization [15]. The continuous-phase composition is consequently an important part of the actuation design.
Magnetic droplet manipulation has been studied in several responsive liquid systems [16,17,18]. Poulose and coworkers tuned the susceptibility of aqueous solutions with paramagnetic salts and investigated the deformation and necking of pendant droplets [19]. Stable TEMPO-type nitroxide radicals provide another means of tuning solution magnetism; their response has been examined using electron paramagnetic resonance and magnetometry [20,21]. Their use in a fully immersed two-liquid system permits the relation between susceptibility contrast and translational motion to be examined.
Here, aqueous 4-hydroxy-TEMPO (TEMPOL) is dispersed in diamagnetic phenylmethyl silicone oil. TEMPOL contains an unpaired electron and contributes a paramagnetic response [22,23], while water has a dimensionless SI volume susceptibility of [24]. Their contributions partly compensate as the TEMPOL concentration decreases. We use the term “weakly magnetic droplets” throughout and report the measured susceptibility of each sample explicitly.
The study combines Gouy-balance measurements at eight concentrations, an analytical permanent-magnet field, and migration measurements at four droplet volumes. All 32 full-path experiments cover in silicone oil. A common fixed-height model tests the concentration and volume dependence with and . Measured densities, a numerical convergence check, and an uncertainty analysis establish the input values and the scope of this comparison. The resulting residuals are used to discuss the possible roles of height, interfacial conditions, and hydrodynamic resistance.
2. Theoretical Model
2.1. Magnetic Kelvin Force and Susceptibility Contrast
Throughout this paper, denotes the dimensionless SI volume susceptibility, defined by . Here, is magnetization and is magnetic field strength; subscripts d and c denote the dispersed and continuous phases. Mass and molar susceptibilities have units of and , respectively. The magnetic Kelvin body-force density is [3]
where . For a linear, weakly magnetic phase with uniform susceptibility, . In a current-free region,
For an immersed droplet of volume V, the net magnetic force includes the response of the displaced continuous phase [25,26]:
Positive drives the droplet toward larger , while negative reverses the direction. The fivefold-diluted sample has and , giving . Its motion is therefore consistent with the susceptibility contrast between the two weakly magnetic liquids.
2.2. Continuous-Phase Pressure Contribution
The magnetic body force in the continuous phase establishes a magnetic contribution to its pressure. In the local quasi-static balance, [26]. If S is a closed surface surrounding the droplet and is its outward unit normal, the pressure force is
Adding the droplet’s own magnetic force gives
Here, is the continuous-phase magnetic pressure and is a surface-area element. The approximation assumes , an approximately spherical droplet, and a field gradient that varies moderately over the droplet scale. The term explicitly includes the surrounding liquid. Viscous stresses associated with motion are represented by the drag law below.
2.3. Low-Reynolds-Number Drag and Terminal Velocity
For a sphere of radius R moving at speed U in an unbounded Newtonian liquid, Stokes drag is [27]
where is the continuous-phase dynamic viscosity. A clean Newtonian droplet with internal circulation has the Hadamard–Rybczynski (H–R) drag [28,29,30]
where is the droplet viscosity. We express the effective drag as
The Stokes baseline is ; the clean-droplet value is , tending to as . Interfacial conditions and nearby boundaries can modify the drag [31,32]. All 32 calculations in this work use the same prescribed .
Balancing the in-plane magnetic force and drag at a fixed height gives
where and . Thus,
At fixed geometry and drag coefficient, the model predicts a migration rate proportional to and a migration time proportional to . These relations describe the common-input baseline tested against the experimental data.
2.4. Vertical Forces and Coordinate Convention
The coordinate z increases upward from the magnet center. The vertical magnetic-force component is
We define the buoyancy-corrected weight as positive downward:
where and are phase densities (), V is volume (), and . The upward-positive sum of these forces is . Along the modeled path, , so the magnetic component points toward the magnet for . The measured saturated-solution density exceeds the oil density, making its buoyancy-corrected weight downward as well. For diluted samples, the gravitational contribution depends on their individual density differences. The present horizontal trajectory model holds z fixed; vertical forces are evaluated separately to assess possible height effects.
2.5. Force Scales and Dimensionless Parameters
We use the estimated interfacial tension to assess the spherical approximation. A dimensionless measure comparing magnetic forcing with interfacial tension is
where the gradient is three-dimensional. The characteristic interfacial force is ; with , . This parameter is used as a force-scale check together with the observed droplet shapes. A full interfacial-stress calculation would also account for the spatial variation of the field and interface geometry.
The capillary, Reynolds, and Weber numbers are , , and . Where both phase densities are measured, the gravitational Bond number is . Their values are reported in Section 5.2. In the current spherical Stokes model, is used to assess the shape approximation, while migration time is calculated from Equation (10).
3. Magnetic-Field Calculation and Trajectory Simulation
3.1. Magnetic-Field Model
The permanent magnet is an N52 NdFeB cube of side length , magnetized along z. Its remanent flux density is set to the nominal value . The magnet is centered at the origin and occupies , where . A surface-magnetic-charge representation gives the exterior field [33]:
where , , and is the distance to vertex . In these field equations the subscripts index vertices; the trajectory release coordinates are specified separately below. The logarithms can be made dimensionless using a common reference length, which cancels in the alternating sums. The implementation uses the two-argument arctangent to retain quadrant information; above the magnet, , it agrees with Equation (15). The squared field includes all three components, . Its gradient is evaluated by central differences with a spatial step of ().The resulting field maps are shown in Figure 1.
Figure 1.
Calculated magnetic-field maps for a cubic magnet with : (a) in the plane; (b) the exterior cross-section at . The magnet boundary and the common calculation height are indicated. The maps are obtained from the analytical permanent-magnet model.
Figure 2 shows the corresponding one-dimensional profiles used in the migration calculation. At , the calculation plane lies above the upper magnet face. The field above the magnet center is . The gradients increase near the projected magnet edge, producing the nonuniform forcing used in the migration calculation.
Figure 2.
Calculated profiles based on the analytical permanent-magnet model. (a–c) Lateral scans at : (a) axial field for (solid) and (dashed); (b) lateral gradient ; (c) lateral squared-field gradient . (d–f) Vertical scans along : (d) axial field ; (e) vertical gradient ; (f) vertical squared-field gradient . The shaded region in (a–c) denotes –; the dashed line in (d) marks .
At and , equals 22.97 and in the and sections, respectively, a difference of approximately 4.1% relative to the former. The plotted cross-sections illustrate the field variation; each trajectory step uses the gradient at the droplet’s current position.
3.2. Trajectory Simulation Program
The model integrates at the prescribed height . Under a lumped-mass, linear-drag approximation, the inertial relaxation time is
where is droplet mass. For –, , , and , this estimate is 1.75–. It is short compared with the experimental migration times of 3.5–, supporting a quasi-steady approximation for the modeled motion.
Trajectories are integrated using fourth-order Runge–Kutta with a time step of . Timing ends at the first crossing of , with linear interpolation within the final step. All 32 simulations start at , use , and adopt the measured susceptibilities in Table 2. The oil kinematic viscosity is ; with , the dynamic viscosity is . Halving the time step changes the 32 calculated passage times by less than 0.0001% in relative terms.
The three illustrative cases in Figure 3 follow the same geometric path because scales the velocity field by a constant. Their travel times differ accordingly: the A/B ratio is , and the C/B ratio is . These examples illustrate the model scaling; the 32-case comparison uses the measured sample susceptibilities. The common height is a model input referenced to the magnet center. Its relation to the experimental container geometry is described in Section 4.1.
Figure 3.
Calculated trajectories at and : (a) and the common in-plane trajectory starting at ; (b) for three illustrative cases. Cases A and B have and volumes 0.5 and ; Case C has and volume . All use and (). The full comparison interval is .
4. Experimental Methods and Results
4.1. Materials and Experimental Setup
The dispersed phase consists of saturated aqueous TEMPOL at and threefold- to ninefold-diluted solutions. All 32 full-path experiments use phenylmethyl silicone oil with nominal kinematic viscosity . Its measured mean density is , giving for the calculations. Droplets are dispensed with a microsyringe at volumes of 0.5, 1.0, 1.5, and , with a dispensing resolution of ; the corresponding radii are approximately 0.49–.
The sample cell is a square polypropylene container above the magnet. Its floor thickness is , the oil depth is , and the initial droplet–inner-floor separation is described in the experimental record as approximately . Motion is recorded with a stereomicroscope and camera; millimeter graph paper provides the positional reference (Figure 4). The separation between the outer cell floor and the magnet surface was not quantitatively recorded. The injection separation and model coordinate therefore have distinct references: is the common calculation plane, above the magnet face at . The influence of height is evaluated in Section 5.3. The analyzed droplets moved within the oil, with no direct contact with the floor or side walls observed; contact with a wall markedly restricted their motion.
Figure 4.
Experimental setup. The sample cell is located above the permanent magnet and imaged with a stereomicroscope and camera. The original setup photograph is retained.
The physical properties and geometry used in the calculations are collected in Table 1.
Table 1.
Physical properties and geometry used in the revised calculations.
Two datasets are distinguished. The 32 full-path measurements cover , a distance of , for eight concentrations and four volumes. Separately, saturated and fivefold-diluted droplets of 1.0 and are timed over a far-field zone () and a near-field zone (), each long. Average speeds use the corresponding interval length divided by passage time. The recording resolution for passage time is approximately . The original time observations are retained throughout the reanalysis.
4.2. Calibration of Dispersed-Phase Susceptibility
Susceptibility is measured with a Gouy magnetic balance using pure water, , as the reference. Readings for the empty and filled tubes are used for background subtraction, and the force response in the nonuniform field provides relative calibration. This procedure follows the Gouy measurement principle [34]. The measured oil susceptibility is . Table 2 and Figure 5 give the solution results.
Figure 5.
Measured dimensionless SI volume susceptibility of aqueous TEMPOL: (a) all eight concentration points and their ordinary least-squares fit (the orange-filled point indicates the concentration with susceptibility closest to zero); (b) an enlarged view of the diluted samples. The measured oil susceptibility is shown for comparison. The fivefold-diluted measurement and its fitted value are distinguished. The fit describes the concentration trend; pointwise measurement uncertainties have not been assigned from the fit residuals.
Table 2.
Calibrated volume susceptibilities of aqueous TEMPOL solutions.
An ordinary least-squares fit to the eight points gives
where c is expressed in . The fitted zero crossing is , with a standard error of approximately . This estimate propagates the covariance of the slope and intercept, with concentration treated as fixed and residuals assumed independent and homoscedastic [35]. It quantifies uncertainty in the fitted zero crossing.
At , the fivefold-diluted sample has measured , compared with a fitted value of approximately . Their difference is . The overall summarizes the concentration trend, while accuracy near zero depends on measurement and calibration uncertainties. Repeated controls using the same empty tube and equal amounts of water at three field settings gave mass-difference standard deviations of 0.000219, 0.000069, and . The largest change in the mean reading difference between field settings was , including the response to the field change. These controls characterize background subtraction and reading repeatability. A complete uncertainty estimate for each solution additionally requires its repeated susceptibility measurements and calibration data.
The term “weakly magnetic” is used for the droplets, with each measured value stated explicitly. All samples have positive , ranging from to . The migration calculations use measured for the fivefold dilution. Substituting its fitted value would give and reduce calculated time by approximately 7.3% at the same other inputs; both choices predict the same migration direction.
4.3. Experimental Results
4.3.1. Saturated TEMPOL Droplets
Saturated droplets () migrate toward the magnet edge. The passage times are for and for , giving average speeds of 1.000 and .Representative image sequences are shown in Figure 6. Separately measured zone times are listed in Table 3. Near-field speeds are 1.5–1.7 times the far-field speeds.The average zone speeds are compared in Figure 7. Doubling the volume increases these speeds by factors of 1.20 in the far field and 1.33 in the near field, consistent with increasing magnetic forcing but below the model factor .
Figure 6.
Original image sequences for saturated TEMPOL droplets: (a,b) at release and after ; (c,d) at release and after . The full-path record covers . The arrow indicates motion toward the high-field region.The lighter (white) region on the right marks the magnet location.
Table 3.
Zone-resolved migration times and average speeds in the far and near fields. The far- and near-field intervals are and , respectively; each spans .
Figure 7.
Measured average far-field and near-field speeds of saturated droplets at volumes of 1.0 and . Each speed is calculated from the corresponding zone length and passage time in Table 3.
4.3.2. Fivefold-Diluted Weakly Magnetic Droplets
The fivefold-diluted sample tests migration at small measured absolute susceptibility, , while retaining a positive contrast with the oil. Its composition contains molecular TEMPOL and water, without added solid magnetic particles.
The 1.0 and droplets traverse in 14.5 and , respectively, giving average speeds of 0.345 and . Image sequences for these weakly magnetic droplets are shown in Figure 8. Their positive accounts for motion toward larger . In the separate zone measurements, far-field speeds are 0.222– and near-field speeds are 0.364–. Saturated droplets move 2.75–3.00 times faster in these zones; this ratio is below their susceptibility-contrast ratio of 4.95.
Figure 8.
Original image sequences for fivefold-diluted TEMPOL droplets: (a,b) at release and after ; (c,d) at release and after . The full-path record covers . The arrow indicates motion toward the high-field region.
A side-by-side comparison of saturated and fivefold-diluted zone speeds is given in Figure 9.
Figure 9.
Measured average zone speeds of saturated and fivefold-diluted TEMPOL droplets: (a) ; (b) . The far- and near-field intervals each span .
4.3.3. Concentration–Volume Scan: Experiment–Simulation Comparison
All 32 simulations use the common interval, , , and . The comparison is shown in Figure 10, Table 4, and Appendix A. With relative error defined using experimental time as the denominator, the mean absolute percentage error (MAPE) is 26.42%, root-mean-square error (RMSE) is , and Pearson correlation coefficient is . Fifteen cases lie within 25% relative error; the maximum is 54.48%. The mean signed relative error, , is .
Figure 10.
Comparison of all 32 full-path measurements and calculations. (a) Calculated versus experimental migration time; the diagonal denotes equality and the band denotes relative error. (b) Signed relative error versus dilution for each droplet volume; connecting lines guide the eye. All calculations use oil, , , , , , and .
Table 4.
Representative migration times over , with and .
For the fivefold-diluted droplet, calculated and experimental times are 14.72 and , respectively, an error of 1.54%. For the saturated droplet, they are 2.97 and , an error of 40.52%. These examples illustrate the variation in agreement across the dataset.
The mean ratios are 0.921, 1.212, 1.379, and 1.555 for volumes 0.5, 1.0, 1.5, and , respectively. Thus, the experimental volume dependence is weaker than the common spherical-model prediction. The mean ratio across all cases is 1.267. By concentration, the saturated and ninefold-diluted groups have mean ratios of 1.670 and 1.725, while the threefold- to sixfold-diluted groups range from 0.950 to 1.111. These residuals motivate the discussion of height and drag in Section 5.3.
The model gives and . In the diluted experimental series, linear rate fits have –0.991 and extrapolated zero-rate contrasts of –. The saturated rates fall below these extrapolations. Experimental volume exponents are for the saturated sample and to for diluted samples. The fitted trends support the role of susceptibility contrast and quantify deviations from the fixed-geometry scaling; the extrapolated intercepts are empirical descriptors of the measured range.Concentration and volume scaling trends are summarized in Figure 11.
Figure 11.
Concentrationand volume scaling. (a) Experimental migration rates over the full susceptibility-contrast range, with the common-input model curves. (b) The diluted experimental series and ordinary least-squares fits. (c) Log–log migration time versus volume for saturated and fivefold-diluted samples, with model reference curves. (d) Experimental volume exponents from log–log fits for all eight concentrations; the horizontal reference is the model exponent .
5. Force Analysis and Discussion
5.1. Force Magnitudes
The forces are evaluated along the simulated trajectories from to at . The in-plane position changes during integration, and the full three-dimensional gradient is used for the vertical-force and shape assessments. Table 5 and Figure 12a report the four representative cases.
Table 5.
Force magnitudes along the simulated paths at . Values are in .
Figure 12.
Forces and horizontal speeds with , , and . (a) Horizontal and vertical magnetic-force magnitudes along the simulated paths for droplets; the dotted line gives the buoyancy-corrected weight of the saturated droplet. (b,c) Local model speeds for 1.0 and droplets, respectively. Dashed horizontal lines show full-path experimental mean speeds. Circles and squares show separate near- and far-zone means; their horizontal bars mark the spatial averaging intervals. Blue and orange identify saturated and fivefold-diluted samples throughout.
Water, saturated TEMPOL solution and silicone oil were each measured ten times. Their mean densities are 0.99350, 1.02660 and , with sample standard deviations of 0.00197, 0.00198 and , respectively. The saturated-solution–oil density difference is therefore . With , the downward buoyancy-corrected weights of 1.0 and saturated droplets are and . Diluted-solution densities remain to be measured, so their buoyancy-corrected weights are left open in Table 5.
For a saturated droplet, the horizontal magnetic-force magnitude increases from at release to a peak of . The vertical magnetic force is directed toward the magnet and increases in magnitude from to at the endpoint. Both the vertical magnetic force and buoyancy-corrected weight act downward for the saturated solution. Their consequences for actual droplet height depend on the container geometry and hydrodynamic resistance. During the analyzed migration, droplets moved within the oil, with no direct contact with the floor or side walls observed. Direct contact with a wall restricted motion.
5.2. Dimensionless Parameters and the Spherical Approximation
The peak values of for the four representative trajectories range from 0.0032 to 0.0252 (Table 6). The estimated interfacial tension, , gives interfacial force scales and for 1.0 and , respectively. Lowering by in a sensitivity calculation raises the largest to 0.0280. These force scales support the spherical approximation over the modeled interval. Here, is used to assess that approximation; the migration time follows the spherical Stokes model.
Table 6.
Dimensionless parameters for the four representative cases.
Using the full-path experimental average speeds gives –, – and –0.074. The measured saturated-solution density gives –0.0087. The small capillary, Weber and gravitational Bond numbers support weak deformation, while supports a leading-order Stokes-drag baseline for the measured average motion. Using the magnitude of the local in-plane model velocity gives a maximum for the saturated droplet, at a speed of . This is also the largest local model Reynolds number in the 32-case series, since the common-geometry value scales with . The Stokes model is therefore used as a leading-order viscous approximation; finite-inertia corrections may contribute to the residuals for the fastest calculated motion.
5.3. Height, Effective Drag and Model Residuals
All 32 calculations use the same plane and baseline. With other inputs fixed, changing the height from 26 to increases the calculated times by a factor of approximately 1.925 and changes the mean absolute percentage error (MAPE) from to . This sensitivity follows from the local magnetic-field gradient. The chosen calculation height provides a common comparison condition; the actual droplet-height trajectories and wall gaps require independent measurement.
The mean experimental-to-model time ratios at volumes of 0.5, 1.0, 1.5 and are 0.921, 1.212, 1.379 and 1.555, respectively. The overall mean is 1.267. These ratios summarize the residual volume dependence. The drag coefficient remains fixed at one throughout this comparison. Possible contributions to the residuals include height-dependent magnetic forcing, near-wall flow and interfacial conditions. The increased resistance of a rigid sphere moving parallel to a wall provides a physical basis for discussing wall effects [32]; its quantitative correction depends on the wall gap and boundary conditions. Trace interfacial impurities may also suppress internal circulation [31]. The present migration-time data constrain the combined model response, while separate height and interface measurements would help resolve these contributions.
5.4. Full-Path and Zone-Resolved Timing
The experimental records identify the full-path interval as , with a distance of . The separate near- and far-zone measurements cover and , respectively, each spanning . Average speeds in Table 7 equal the corresponding distance divided by the recorded passage time. Model full-path speeds equal divided by the calculated endpoint time.
Table 7.
Full-path average speeds and the separate zone-resolved measurements.
For the saturated droplet, the full-path time is over , and the near-zone time is over ; both give an average speed of . The corrected spatial interval resolves the earlier distance–time discrepancy. The zone measurements were acquired separately and illustrate the higher near-field speed. The full set of 32 full-path times provides the common interval used for the quantitative model comparison.
5.5. Susceptibility Matching and Migration Direction
Equation (11) predicts vanishing magnetophoresis at and a reversal of direction for . Every measured sample has positive contrast, with a minimum of . The measured oil susceptibility () is close to the water reference (), so water-rich droplets provide a useful control near the matching condition. Testing a direction reversal would require a negative contrast, achieved through the choice of dispersed or continuous phase.
5.6. Input Sensitivities and Uncertainty Propagation
Uncertainties are expressed as standard uncertainties following the Guide to the Expression of Uncertainty in Measurement [35]. For the fixed-height trajectory with , integration of Equation (10) gives
where s is in-plane arc length, is the gradient in that plane, and ends at . At fixed geometry, . The relative sensitivities and quantified components are summarized in Table 8.
Table 8.
Relative sensitivities and quantified input contributions for the fixed-height model.
For ten repeated density measurements, the Type A standard uncertainty of each mean is . The resulting uncertainties for water, saturated solution and oil are 0.000623, 0.000626 and , respectively. Treating the two phase-density means as independent gives , or of their difference. The individual relative contributions are from the saturated solution and from the oil. These quantities describe repeatability contributions. At fixed , the measured oil-density repeatability contributes , or , to viscosity and hence to the model time.
Uniform rounding over one resolution interval gives and . Over the measured ranges, volume rounding contributes – to model time and timing rounding contributes – to experimental time. A separate conservative reading allowance of corresponds to –. For remanence, increasing by shortens the model time by , whereas reducing it by lengthens the time by . These are sensitivity calculations around the nominal .
The susceptibility-contrast uncertainty includes the covariance introduced by shared calibration:
For independent , , V and at fixed geometry, first-order propagation gives
Correlated inputs and position changes are included through , where is the sensitivity vector and is the input covariance matrix. Position sensitivities follow from trajectory calculations. Field-amplitude uncertainty enters through , while viscosity uncertainty is obtained from , and their covariance. The fixed is a model setting; departures of the actual drag from that baseline are discussed as model error.
The present analysis quantifies density repeatability and volume and timing rounding, and provides the sensitivities of the remaining inputs. A complete numerical uncertainty budget additionally requires calibration and systematic-error information for susceptibility, kinematic viscosity, remanence and position. The 32-case MAPE of and root-mean-square error of are reported separately as measures of the residual experiment–model differences. Direct field calibration, synchronized position and height tracking, and measurements of viscosity and interfacial tension at the experimental temperature would tighten the comparison.
6. Conclusions and Outlook
This study combines susceptibility measurements, migration experiments, and numerical calculations for weakly magnetic aqueous TEMPOL droplets immersed in diamagnetic silicone oil. The measured solution susceptibility varies approximately linearly with concentration (), spanning to . The fivefold-diluted sample has a measured susceptibility of and a positive contrast of relative to the oil. Its 1.0 and droplets migrate toward the high-field region in 14.5 and , respectively. These observations support magnetic transport governed by the susceptibility contrast between the two phases, without added solid magnetic particles.
All 32 concentration–volume combinations were recalculated over using the same inputs: oil, measured density , , , and . The resulting MAPE is 26.42%, RMSE is , and Pearson r is 0.818; 15 of 32 cases lie within a 25% relative-error band. The concentration trend is broadly reproduced, while the volume-dependent residuals show the limitations of a common fixed-height, constant-drag description.
The continuous-phase pressure contribution leads directly to the susceptibility-contrast force. Force-scale and relaxation-time estimates support a quasi-steady spherical approximation for the modeled horizontal motion. The measured densities and input-sensitivity analysis clarify the roles of buoyancy, viscosity, field strength, and position. Direct height tracking, magnetic-field calibration, and measurements of viscosity and interfacial properties would permit these effects to be resolved more fully. The present data provide a basis for extending susceptibility-controlled droplet transport and for testing three-dimensional models with measured boundary conditions.
Author Contributions
Investigation, Y.M., with assistance from Y.W. (Yanfang Wu) in magnetic measurements; methodology and software, Y.W. (Youshen Wu); supervision, L.Z. All authors have read and agreed to the published version of the manuscript.
Funding
This work was supported by the National Natural Science Foundation of China (NSFC No. T2425029).
Institutional Review Board Statement
Not applicable. This study does not involve humans or animals.
Informed Consent Statement
Not applicable.
Data Availability Statement
The complete set of 32 experimental and simulated migration times is provided in Table A1.
Acknowledgments
The authors thank Shengli Zhang for helpful discussions.
Conflicts of Interest
The authors declare no conflicts of interest.
Appendix A. Full Experimental and Simulated Migration-Time Dataset
All experimental times in Table A1 are retained from the supplied 32-case dataset. The full-path interval is . Simulations start at and use , , , and . Relative error is . Calculated times are rounded for display; statistics use unrounded values. Experimental and calculated average speeds follow from the corresponding passage times as .
Table A1.
All 32 experimental and simulated migration times over .
References
- de Gennes, P.G. Soft matter. Rev. Mod. Phys. 1992, 64, 645–648. [Google Scholar] [CrossRef] [Scilit]
- Nguyen, N.T. Micro-magnetofluidics: Interactions between magnetism and fluid flow on the microscale. Microfluid. Nanofluid. 2012, 12, 1–16. [Google Scholar] [CrossRef] [Scilit]
- Rosensweig, R.E. Ferrohydrodynamics; Cambridge University Press: Cambridge, UK, 1985. [Google Scholar]
- Beaugnon, E.; Tournier, R. Levitation of organic materials. Nature 1991, 349, 470. [Google Scholar] [CrossRef] [Scilit]
- Ikezoe, Y.; Hirota, N.; Nakagawa, J.; Kitazawa, K. Making water levitate. Nature 1998, 393, 749–750. [Google Scholar] [CrossRef] [Scilit]
- Simon, M.D.; Geim, A.K. Diamagnetic levitation: Flying frogs and floating magnets (invited). J. Appl. Phys. 2000, 87, 6200–6204. [Google Scholar] [CrossRef] [Scilit]
- Liu, T.; Wang, Q.; Yuan, Y.; Wang, K.; Li, G. High-gradient magnetic field-controlled migration of solutes and particles and their effects on solidification microstructure: A review. Chin. Phys. B 2018, 27, 118103. [Google Scholar] [CrossRef] [Scilit]
- Ikezoe, Y.; Kaihatsu, T.; Sakae, S.; Uetake, H.; Hirota, N.; Kitazawa, K. Separation of feeble magnetic particles with magneto-Archimedes levitation. Energy Convers. Manag. 2002, 43, 417–425. [Google Scholar] [CrossRef] [Scilit]
- Winkleman, A.; Perez-Castillejos, R.; Gudiksen, K.L.; Phillips, S.T.; Prentiss, M.; Whitesides, G.M. Density-based diamagnetic separation: Devices for detecting binding events and for collecting unlabeled diamagnetic particles in paramagnetic solutions. Anal. Chem. 2007, 79, 6542–6550. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Mirica, K.A.; Shevkoplyas, S.S.; Phillips, S.T.; Gupta, M.; Whitesides, G.M. Measuring densities of solids and liquids using magnetic levitation: Fundamentals. J. Am. Chem. Soc. 2009, 131, 10049–10058. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Kose, A.R.; Fischer, B.; Mao, L.; Koser, H. Label-free cellular manipulation and sorting via biocompatible ferrofluids. Proc. Natl. Acad. Sci. USA 2009, 106, 21478–21483. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Zhu, T.; Marrero, F.; Mao, L. Continuous separation of non-magnetic particles inside ferrofluids. Microfluid. Nanofluid. 2010, 9, 1003–1009. [Google Scholar] [CrossRef] [Scilit]
- Zhu, T.; Lichlyter, D.J.; Haidekker, M.A.; Mao, L. Analytical model of microfluidic transport of non-magnetic particles in ferrofluids under the influence of a permanent magnet. Microfluid. Nanofluid. 2011, 10, 1233–1245. [Google Scholar] [CrossRef] [Scilit]
- Shen, F.; Hwang, H.; Hahn, Y.K.; Park, J.K. Label-free cell separation using a tunable magnetophoretic repulsion force. Anal. Chem. 2012, 84, 3075–3081. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Durmus, N.G.; Tekin, H.C.; Guven, S.; Sridhar, K.; Yildiz, A.A.; Calibasi, G.; Ghiran, I.; Davis, R.W.; Steinmetz, L.M.; Demirci, U. Magnetic levitation of single cells. Proc. Natl. Acad. Sci. USA 2015, 112, E3661–E3668. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Zhu, G.-P.; Wang, Q.-Y.; Ma, Z.-K.; Wu, S.-H.; Guo, Y.-P. Droplet manipulation under a magnetic field: A review. Biosensors 2022, 12, 156. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Li, J.; Su, K.; Liu, H.; Zou, Y. Recent advances in magnetically actuated droplet manipulation for biomedical applications. Magnetochemistry 2024, 10, 28. [Google Scholar] [CrossRef] [Scilit]
- Kim, J.H.; Kang, S.M.; Lee, B.J.; Ko, H.; Bae, W.-G.; Suh, K.Y.; Kwak, M.K.; Jeong, H.E. Remote manipulation of droplets on a flexible magnetically responsive film. Sci. Rep. 2015, 5, 17843. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Poulose, S.; Quirke, J.A.; Stamenov, P.; Möbius, M.E.; Coey, J.M.D. Deformation and necking of liquid droplets in a magnetic field. Phys. Fluids 2022, 34, 112116. [Google Scholar] [CrossRef] [Scilit]
- Matsumoto, N.; Shimosaka, T. Purity analyses of high-purity organic compounds with nitroxyl radicals based on the Curie–Weiss law. J. Appl. Phys. 2015, 117, 17E114. [Google Scholar] [CrossRef] [Scilit]
- Matsumoto, N.; Shimosaka, T. Low-temperature electronic paramagnetic resonance measurements of TEMPO and 4-hydroxy-TEMPO benzoate for purity analyses by the effective magnetic-moment method. Anal. Sci. 2017, 33, 1059–1065. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Haugland, M.M.; Anderson, E.A.; Lovett, J.E. Tuning the properties of nitroxide spin labels for use in electron paramagnetic resonance spectroscopy through chemical modification of the nitroxide framework. In Electron Paramagnetic Resonance; Chechik, V., Murphy, D.M., Eds.; Royal Society of Chemistry: Cambridge, UK, 2017; Volume 25, pp. 1–34. [Google Scholar] [CrossRef] [Scilit]
- Torricella, F.; Pierro, A.; Mileo, E.; Belle, V.; Bonucci, A. Nitroxide spin labels and EPR spectroscopy: A powerful association for protein dynamics studies. Biochim. Biophys. Acta-Proteins Proteom. 2021, 1869, 140653. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Doudin, B.; Coey, M.; Cēbers, A. Magnetic Microhydrodynamics: An Emerging Research Field; Springer International Publishing: Cham, Switzerland, 2024. [Google Scholar]
- Watarai, H.; Namba, M. Magnetophoretic Behavior of Single Polystyrene Particles in Aqueous Manganese(II) Chloride. Anal. Sci. 2001, 17, 1233–1236. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Tajfirooz, S.; Meijer, J.G.; Dellaert, R.A.; Meulenbroek, A.M.; Zeegers, J.C.H.; Kuerten, J.G.M. Direct numerical simulation of magneto-Archimedes separation of spherical particles. J. Fluid Mech. 2021, 910, A52. [Google Scholar] [CrossRef] [Scilit]
- Stokes, G.G. On the effect of the internal friction of fluids on the motion of pendulums. Trans. Camb. Philos. Soc. 1851, 9, 8–106. [Google Scholar]
- Hadamard, J. Mouvement permanent lent d’une sphère liquide et visqueuse dans un liquide visqueux. C. R. Acad. Sci. Paris 1911, 152, 1735–1738. [Google Scholar]
- Rybczynski, W. Über die fortschreitende Bewegung einer flüssigen Kugel in einem zähen Medium. Bull. Acad. Sci. Crac. Ser. A 1911, 1, 40–46. [Google Scholar]
- Kim, S.; Karrila, S.J. Microhydrodynamics: Principles and Selected Applications; Butterworth-Heinemann: Boston, MA, USA, 1991. [Google Scholar]
- Taylor, T.D.; Acrivos, A. On the deformation and drag of a falling viscous drop at low Reynolds number. J. Fluid Mech. 1964, 18, 466–476. [Google Scholar] [CrossRef] [Scilit]
- Goldman, A.J.; Cox, R.G.; Brenner, H. Slow viscous motion of a sphere parallel to a plane wall—I. Motion through a quiescent fluid. Chem. Eng. Sci. 1967, 22, 637–651. [Google Scholar] [CrossRef] [Scilit]
- Furlani, E.P. Permanent Magnet and Electromechanical Devices: Materials, Analysis, and Applications; Academic Press: San Diego, CA, USA, 2001. [Google Scholar]
- Brubacher, L.J.; Stafford, F.E. Magnetic susceptibility: A physical chemistry laboratory experiment. J. Chem. Educ. 1962, 39, 574. [Google Scholar] [CrossRef] [Scilit]
- JCGM 100:2008; Evaluation of Measurement Data—Guide to the Expression of Uncertainty in Measurement. Bureau International des Poids et Mesures: Sèvres, France, 2008. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.