Skip to Content
Future TransportationFuture Transportation
  • Article
  • Open Access

6 October 2026

14 Pages

Validating Multi-Parameter PEMFC Simulation Models for Vehicle Powertrain Diagnostics

and
Department of Innovative Vehicles and Materials, GAMF Faculty of Engineering and Computer Science, John von Neumann University, H-6000 Kecskemét, Hungary
*
Author to whom correspondence should be addressed.

Abstract

Predictive maintenance in hydrogen mobility requires digital twin models that can reproduce the internal operating state of proton exchange membrane fuel cells (PEMFCs) with sufficient accuracy and computational efficiency. This study develops and validates a three-dimensional Multiphysics PEMFC model based on experimental measurements from a single-cell prototype with a 16 cm2 active area. The model was implemented in COMSOL Multiphysics 6.1 and couples electrochemical reaction kinetics, electronic and protonic charge transport, multicomponent gas transport, laminar channel flow, membrane water transport, and heat generation. An optimized mesh resolution was selected to reduce computational demand while maintaining numerical accuracy. Validation was performed against measurements obtained using a Scribner 850 fuel cell testing system under different gas flow velocities and relative humidities. The simulated maximum current density differed from the measured value by less than 0.4%, while the peak power density differed by approximately 1.0%. The largest relative discrepancy occurred in the activation-controlled region, whereas close agreement was observed in the ohmic region. Spatial distributions of reactants, water, velocity, and heat generation were also evaluated to assess the physical consistency of the model. This study demonstrates the development and validation of an offline, high-fidelity Multiphysics model. However, this validated framework provides the essential physical foundation for generating surrogate models needed for future real-time diagnostic digital twin applications in fuel cell electric vehicles.

1. Introduction

Hydrogen-based electrochemical energy conversion is increasingly relevant for sustainable mobility. Proton exchange membrane fuel cells (PEMFCs) convert hydrogen and oxygen directly into electricity, heat and water and their low operating temperature, fast start-up capability, and high power-density potential make them attractive for vehicle powertrains, especially where long range and short refueling time are required [1,2].
Practical PEMFC performance is governed by coupled electrochemical, thermal, and transport phenomena rather than by a single isolated component. The polarization curve is therefore a useful validation asset, but a diagnostic model must also provide physically plausible internal variables such as reactant distribution, water content, local current density, and heat generation [3,4].
Figure 1 schematic was created by the authors based on established PEMFC physical theory [3,5,6].
Figure 1. Polarization curve regional losses.
The PEMFC modelling has progressed from low-dimensional semi-empirical formulations toward three-dimensional Multiphysics models. Modern approaches combine equilibrium voltage calculation, charge conservation, electrode kinetics, species transport, porous-media transport, fluid flow, and heat dissipation so that activation, ohmic, and concentration losses can be evaluated within one coupled framework [5,6]. Among others, water management remains one of the most critical couplings in PEMFC operation. Experimental and numerical studies have shown that product water accumulation, membrane hydration, and oxygen starvation are strongly affected by flow-field geometry, gas diffusion layer behavior, and inlet humidity [7,8]. Flow-field reviews also show that channel layout influences reactant uniformity, pressure drop, and water removal, which is directly relevant to the investigated parallel serpentine quad channel design [9,10].
Digital twins introduce stricter requirements than conventional offline simulations because the virtual model must remain connected to the physical system through measured inputs, parameter updates, or diagnostic feedback. In engineering applications, digital twins are mainly used for condition monitoring, anomaly detection, predictive maintenance, and operation support [11,12]. For hydrogen powertrains, this means the PEMFC model should help distinguish normal load-induced voltage variation from faults such as dehydration, flooding, gas starvation, thermal nonuniformity, and degradation [13,14]. Predictive maintenance is directly connected to this modelling task because PEMFC faults usually develop gradually before they appear as complete system failure. Instead of replacing components according to fixed service intervals, predictive maintenance uses measured operating data and model-based health indicators to estimate the current condition of the stack and to predict whether degradation is approaching a critical threshold. Inside a PEMFC powertrain, useful early indicators are increasing voltage residuals, rising ohmic losses caused by membrane drying, increasing concentration losses caused by oxygen starvation or flooding, and abnormal heat-generation patterns under comparable load conditions [12,13].
Recent FCEV advances highlight synergistic electro-thermal control for durability optimization, hybrid dynamic prognostic frameworks (such as AEKF combined with random forest), and cross-domain transfer learning for online degradation prediction. These advanced algorithms rely on physically accurate baseline models, such as the high-fidelity 3D framework developed in this study [15,16,17].
In the present framework, predictive maintenance can be achieved by combining vehicle or test-bench sensor data with a validated Multiphysics model and a diagnostic decision layer. Current, voltage, pressure, temperature, humidity, and flow-rate signals provide the measured boundary conditions, while the model estimates virtual internal variables, such as reactant availability, water distribution, electrolyte potential, and heat generation. The resulting measured and simulated deviations can be used to classify operating states, detect flooding or drying tendencies, support remaining useful-life assessments, and recommend control actions such as humidification correction, cathode-flow adjustment, or maintenance scheduling [14,18].
Currently, there is limited availability of experimentally anchored PEMFC simulation models that are detailed enough to represent local internal fields while still being structured toward later real-time diagnostic use. High-fidelity models are often computationally expensive and are mainly used for design studies, whereas control-oriented models can be too simplified to localize transport or hydration-related losses [18,19]. The objective of this work is therefore to validate a multi-parameter PEMFC model against single-cell measurements and to assess whether the resulting internal-field predictions are suitable as a basis for a future powertrain diagnostic digital twin.
The study is guided by two hypotheses. First: the updated Multiphysics model reproduces the measured polarization trend with better accuracy than the previous simulation version. Second: simulated H2, O2, and H2O distributions, flow velocities and heat-generation fields are physically consistent with known PEMFC transport behavior.
For a diagnostic digital twin, agreement in the overall voltage curve is necessary but not sufficient. The model must remain sensitive to operating inputs measured on a test bench or in a vehicle, while its internal fields must respond consistently to those inputs. This requirement motivates the combined evaluation of polarization behavior, reactant distribution, water transport, and heat generation. It also links high-fidelity simulation with later reduced-order implementation because the variables selected for reduction should preserve the mechanisms most relevant to fault detection and maintenance decisions [11,12,18,19].
It is crucial to distinguish between the validated simulation model presented in this study and a fully deployed digital twin. A complete diagnostic digital twin requires real-time execution and continuous data exchange with a physical asset. The present work does not demonstrate a real-time digital twin; rather, it establishes the high-fidelity offline simulation environment. This rigorous physical model is a mandatory prerequisite, as it ensures that the internal fields (e.g., water and species distribution) are physically accurate before they are adapted into faster, real-time-capable diagnostic algorithms.
Finally, it is emphasized that this work presents a validated, high-fidelity offline 3D multi-physics simulation model. While not a fully deployed, real-time connected digital twin in its current form, this physics-based framework establishes the necessary offline benchmark required to train real-time surrogate models for future digital twin deployment.

2. Methodology

2.1. Experimental Cell and Measurement Procedure

The investigated hardware is a single-cell PEMFC prototype with characteristics detailed in Table 1. The cell has a closed-cathode, air-cooled configuration and a parallel serpentine quad-channel flow field. Its primary function in this research is the development and investigation of flow-field behavior and the generation of validation data for numerical modelling.
Table 1. Main properties of the measured PEMFC.
Measurements were performed with a Scribner 850 fuel cell test system (Figure 2a). The controlled variables include anode and cathode mass flow, gas temperature, cell temperature, relative humidity, and back pressure. The experimental protocol consisted of recording voltametric behavior, activation data, and polarization curves. The experimental setup consisted of the Membrane Electrode Assembly (MEA), bipolar plates, current collector-, insulator-, and end plates together with sealings (Figure 2b) [20].
Figure 2. Fuel cell measurement environment (a) and exploded CAD view of the PEMFC test cell assembly (b).
To contextualize the validation results, the inherent measurement uncertainties of the Scribner 850 test system must be considered. Based on the equipment specifications, the accuracy of the controlled and measured variables is as follows: voltage ±3 mV ±0.3% of reading, current ±0.3% of full-scale range, and temperature ±0.25% of span ±1 leas significant digit.

2.2. Numerical Model and Governing Equations

The simulation was built in COMSOL Multiphysics 6.1 with the Fuel Cell and Electrolyzer Module. The model couples electrochemical reaction kinetics, electronic and protonic charge transport, multicomponent gas diffusion, channel flow, and heat generation. This type of formulation is consistent with established PEMFC modelling practice, where the cell voltage is represented by the reversible voltage minus activation, ohmic, and concentration losses [5,6]. The same coupled formulation also allows local fields to be calculated in the gas channels, diffusion layers, and membrane-electrode assembly, which is essential for diagnostic interpretation [3,4].
The mathematical formulation relies on the following key assumptions: (1) the system operates in a steady-state condition; (2) gas mixtures behave as ideal gases; (3) flow in the channels and porous media is strictly laminar; (4) porous materials are isotropic; and (5) water exists strictly in a single-phase gaseous state, neglecting liquid water condensation. The governing equations are standard formulations adopted from established Multiphysics PEMFC modelling.
Gas flow in the open channels was described using mass and momentum conservation, while transport through the porous gas diffusion and catalyst layers was represented by a porous-medium formulation. The transport of hydrogen, oxygen, nitrogen, and water vapor included convection, diffusion and electrochemical source terms. Effective diffusion coefficients were corrected to account for the porosity and tortuosity of the porous materials (Table 2).
Table 2. Governing physical descriptions used in the PEMFC Multiphysics model [5,21,22].
Electronic charge conservation was solved in the electrically conductive components, whereas protonic charge conservation was considered in the membrane and ionomer-containing catalyst layers. The electrochemical reaction rates were determined using Butler–Volmer-type kinetics, with local reaction activity depending on temperature, reactant concentration, and activation overpotential (Table 2).
Thermal transport was also included, considering reaction heat, ohmic heating, and heat transfer through the solid and fluid domains. Since temperature has an influence on reaction kinetics, gas properties, and membrane conductivity, the thermal and electrochemical fields were directly coupled.
The model also considered membrane water transport, including electro-osmotic drag and back-diffusion. These mechanisms affect membrane hydration, protonic conductivity, and the spatial distribution of current density.
Membrane protonic conductivity and water diffusivity correlations were implemented using the standard empirical relationships provided by the COMSOL Fuel Cell Module, evaluated as a function of local membrane water content (λ).
Boundary conditions were defined according to the experimental operating parameters, including inlet gas composition, temperature, pressure, humidity, and flow rate. Electrical conditions were imposed at the current collectors, while thermal conditions represented the controlled cell temperature and heat exchange with the test hardware.
Gas flow rates are reported at standard reference conditions (Standard Liters Per Minute, SLPM, referenced to 273.15 K and 101.325 kPa). In the numerical model, the standard volumetric flow rates were converted to total humidified mass flow rates, accounting for the added water vapor mass based on the specific inlet temperature, absolute pressure, and relative humidity, to serve as accurate inlet boundary conditions. The software internally calculates the input mass flow on both the anode and cathode sides. In Table 3, the inlet gas mass flow is the SLPM quantity that is needed for the software. The pressure, humidity, and temperature of each individual gas have to be applied as separate inlet parameters in Comsol.
Table 3. Boundary conditions used in the PEMFC Multiphysics model.
All gauge pressure boundary conditions specified in Table 3 were converted to absolute pressures by adding a reference atmospheric pressure of 101.325 kPa prior to executing the gas transport and electrochemical calculations.
The coupled formulation provides both global polarization behavior and spatially resolved distributions of gas concentration, velocity, pressure, temperature, overpotential, and current density.

2.3. Mesh Independence and Validation

A mesh-independence study was included to balance numerical accuracy and processing efficiency, which is essential for any later digital-twin implementation. The meshing was based on a structured square mesh with a resolution of 0.25 mm from the top view of the cell, which was applied to different parts of the simulated assembly; the resolution of the mesh can be changed part by part vertically using this method. In the simulation, the following parts of the 3D CAD model were applied: the channel of the bipolar plate, the two GDL layers and the membrane to regulate the inlet and outlet mass flows, and four channel merging plates were used in the simulation model assembly.
Model validation was carried out by comparing simulated and measured polarization curves. Parameter studies were then defined for gas-flow velocity and relative humidity because both variables influence membrane hydration, oxygen access, water removal, and concentration overpotential [7,8].
A mesh-independence analysis was performed by further refining the computational grid from 521,600 to 2,086,400 elements on the original simulation. The average current density increased from 1,317.00 mA/cm2 to 1319.64 mA/cm2, corresponding to a relative difference of approximately 0.2%. Since further mesh refinement resulted in only a negligible change in the calculated current density, the mesh structure containing 521,600 elements was selected for all subsequent simulations as a suitable compromise between numerical accuracy and computational cost. The total number of domain elements is 521,600.
The computational time with the chosen mesh is around 75 min on a desktop i5-10400 with 32 Gb of ddr4 ram.
The validation strategy therefore followed a staged structure. First, operating and material parameters were defined from the experimental cell and controlled test conditions. Second, mesh resolution was selected to limit discretization-related variation without unnecessary computational cost. Third, global electrical behavior was compared through measured and simulated polarization curves. Finally, local species, velocity, and thermal fields were assessed for physical consistency. This sequence is important because a converged solution can still be unsuitable for diagnostics if it reproduces terminal voltage for incorrect internal reasons or if compensating parameter errors conceal unrealistic transport behavior.
To ensure a rigorous validation protocol, a clear distinction was maintained between model calibration and model validation. Geometric dimensions and operational boundary conditions were specified directly from physical measurements (Table 1 and Table 3). Material transport properties were adopted from the established literature and manufacturer specifications. Model calibration was restricted strictly to the electrochemical reaction kinetics: the anode and cathode reference exchange current densities (i0,a, i0,c) were calibrated against the baseline activation polarization region. Subsequent model validation was performed across the measured current density range under baseline conditions by comparing predicted terminal voltage, current density, and power density against experimental polarization curves without any further parameter adjustment.
It should be noted as a primary limitation of this study that experimental validation was performed under a specific baseline operating condition. While this most critical operating setting provides a comprehensive baseline for demonstrating the high-fidelity 3D modelling framework, full experimental validation across a broader multi-parameter operating envelope (varying flow velocities, temperatures, and relative humidities) was not feasible due to limited time and remains a subject for future investigation.
It must be explicitly emphasized that direct experimental validation in this study is limited to global terminal quantities, specifically the polarization performance (cell voltage, current density, and peak power density). Local internal distributions-such as species molar fractions, flow velocity fields, and heat generation represent purely numerical predictions generated by the multi-physics model. In the absence of direct local in-situ measurements, these internal fields are evaluated based on their physical consistency and qualitative agreement with established transport theory in the PEMFC literature.

3. Results

3.1. Overpotential Interpretation

Figure 3 shows the available validation comparison. The corresponding measured polarization curve presented a decreasing voltage with increasing current density, in agreement with expectations. The overpotential behavior can be interpreted through the three classical polarization regions. The initial voltage drop is attributed mainly to activation losses in the catalyst layers. The approximately linear middle region reflects membrane protonic resistance, electronic contact resistance and material conductivity. The high-current deviation reflects mass-transfer limitation and water accumulation, which are standard loss mechanisms in PEMFC polarization analysis [4,5].
Figure 3. Preliminary polarization and power-density comparison between measurement and Comsol simulation versions.
Gas-flow variation is expected to affect mainly the high-current section of the polarization curve. Increased reactant flow improves oxygen availability and water removal, but it may also reduce residence time and increase auxiliary power demand in a full stack system [9,10]. Relative humidity has a more coupled effect: higher humidity supports membrane proton conductivity and reduces ohmic losses, but excessive water content can increase flooding risk and concentration overpotential [7,8].

3.2. Polarization Curve Validation

Based on the characteristic regions of the theoretical polarization curve depicted in Figure 1, the largest relative deviation between the measured and simulated results occurs in the activation-controlled region below approximately 100–150 mA/cm2 (Figure 3). The experimentally measured voltage decreases more rapidly, indicating that the model slightly underestimates the activation losses. This difference may originate from uncertainties in the kinetic parameters, exchange current density, and electrochemically active catalyst surface area. Furthermore, the structural simplification of the standard Butler-Volmer formulation, which neglects intermediate oxygen reduction reaction steps and hydrogen crossover currents, also contributes to this mismatch. In the intermediate ohmic region, the measured and simulated curves show good agreement, confirming that the membrane and electronic charge-transport properties are represented reasonably well. Above approximately 550 mA/cm2, the simulated voltage becomes slightly higher than the measured value, suggesting that the model underestimates the total ohmic and contact resistances. At current densities above approximately 900 mA/cm2, the remaining deviation can also be attributed to underestimated mass-transport losses. Idealized gas diffusion, uniform porous-material properties, and the neglect of liquid-water accumulation may result in more favorable oxygen transport in the simulation than in the experimental cell. This behavior is consistent with PEMFC studies showing that high-current operation amplifies oxygen-transport limitation, product-water accumulation, and local heat dissipation problems [7,23]. The mismatch at very high current densities is smaller because the experimental curve shows shorter linear regions than the simulated one. The general operating region is 0.6–0.5 V, and from a diagnostics perspective, the lower fields are also valuable because deviations between model and measurement may indicate flooding, restricted air supply, local drying, or insufficient parameterization of effective diffusivity [24,25].
The close agreement in the intermediate current-density range is relevant for powertrain use because this region contains a substantial part of the normal steady-state load range. Here, the model represents membrane resistance, electronic conduction, and reactant supply with limited divergence from the measurement. The remaining voltage residual can therefore be interpreted as a diagnostic quantity when evaluated together with temperature, humidity, pressure, and flow rate. A persistent increase in the residual under comparable boundary conditions would indicate that the calibrated model no longer represents the physical cell with the same accuracy, which may justify parameter updating or further condition assessment.
The overall agreement between the measured and simulated polarization curves is quantified by a Root Mean Square Error (RMSE) of 14.48 mV across the entire current density range. When evaluated alongside the Scribner 850 test system’s inherent measurement uncertainties, such as voltage sensor accuracy (±3 mV) and gas mass flow controller tolerances. This deviation is phenomenologically minimal. Consequently, the reported 0.4% difference in maximum current density and 1.0% discrepancy in peak power density are highly significant, as the overall model error of ~14.5 mV approaches the acceptable boundaries of physical repeatability and experimental noise, depicted in in Table 4. This confirms that the simulation captures the baseline internal fields with sufficient fidelity for diagnostic purposes.
Table 4. Measured and simulated data comparison.
The current numerical framework employs a single-phase treatment of water transport. A limitation of this approach is that liquid-water condensation and two-phase flow in porous media are not explicitly modelled. This assumption artificially improves simulated oxygen transport at high current densities, as the pathways are not physically hindered by liquid water accumulation. However, unmodeled liquid water is not the exclusive cause of the observed high-current deviations; other contributing factors include idealized uniform porous-media properties, uncalibrated local variations in effective diffusivity, simplified contact resistances, and uncertainties in high-current kinetic parameters.

3.3. Model-Predicted Internal Reactant Distributions, Flow Fields and Heat Generation

The internal-field results provide the main added value over a purely empirical polarization model. The H2 molar-fraction map indicates the anode fuel distribution and possible fuel depletion along the serpentine path. The O2 map indicates cathode-side access to the reaction zone, where local minima may correspond to concentration-loss hot spots. The H2O map is directly connected to water formation and possible flooding or membrane-hydration effects [7,8]. The fields are spatially non-uniform but physically coherent: reactant fractions change along the flow path, and water concentration increases in reaction-active regions.
The molar fraction of H2 gas in the anode GDL layer is depicted in Figure 4a. 96.6% means the gas contains 3.4% water from the humidifying process of the measurement device. H2 is supplied from the top-left corner of the picture, and the outlet is in the bottom-right corner. The residual 77% is high enough to sustain activity; thus, there is no sharp decline in voltage at high current densities. The channel outlet region of the GDL layer contains 32.9% water, indicating that the model currently implements electroosmotic and back-diffusion phenomena.
Figure 4. Simulated H2 molar fraction (a), gas-phase H2O molar fraction on the cathode side (b), O2 (c), and molar-fraction distributions in the gas diffusion layer and heat distribution (d).
The simulated velocity fields and membrane heat-generation maps further support the diagnostic interpretation. Local high-velocity zones occur along the channel path and at bends, while lower-velocity zones may be associated with poorer convective renewal.
Figure 4b showcases the H2O accumulation in the cathode GDL layer. The inlet is in the bottom-left corner of the picture, and it contains around 3% H2O; at the end of the serpentine channel in the top-right corner, the GDL water content is 61% due to the effective electrocatalytic reaction. It must be noted that this 61% value represents the gas-phase molar fraction. Because the simulation employs a single-phase gas model without liquid water condensation, the water vapor partial pressure is not limited by the saturation condition. At this specific local region (operating at a cell temperature of 353.15 K and a cathode absolute pressure of approximately 331.325 kPa), this simplification leads to a numerically predicted gas-phase water vapor concentration that exceeds physical saturation boundaries. Figure 4c depicts the O2 content of the cathode GDL layer, and it is the opposite of Figure 4b, because the GDL layer cannot take in more oxygen if there is water accumulation in the exact region of the porous layer.
The heat-generation plot (Figure 4d) shows continuous changes in flow fields; thus, reaction kinetics, membrane hydration, and durability are satisfactory throughout the entire cell, in agreement with the experimental data [23,24]. In the present case, species and heat distributions support the laboratory test results. In a vehicle powertrain, such information could be used to mark operating points that promote local degradation even when the total stack voltage remains acceptable.

3.4. Implications for Vehicle Powertrain Diagnostics

For vehicle diagnostics, a validated PEMFC model must work under changing load, humidity, pressure, and temperature conditions. The present framework is a first step because it links controlled measurements to a Multiphysics model and examines variables that have direct diagnostic meaning. Potential diagnostic outputs include estimated oxygen-starvation risk, membrane-drying tendency, flooding tendency, local heat-load indicator, and expected voltage residual. These outputs could support predictive maintenance by distinguishing normal operating variability from early fault signatures [11,13].
In a future real-time diagnostic system, the current offline model will be integrated with measured operating data from the vehicle. Physical sensor readings such as stack voltage, current demand, inlet pressures, temperatures, and mass flow rates will act as continuous boundary conditions. Because the high-fidelity 3D COMSOL simulation is computationally intensive and cannot run in real time on a vehicle’s electronic control unit (ECU), it must be reduced. The validated 3D model presented here will be used offline to generate extensive training datasets. These datasets will then be utilized to train fast-executing surrogate models, such as Reduced Order Models (ROMs), artificial neural networks, or multi-dimensional lookup tables. These surrogate models will replace the computationally heavy finite element calculations, allowing the system to run in real time (within milliseconds) while preserving the physical consistency of the internal fields. The diagnostic twin will then continuously compare the virtual state estimated by the surrogate model against the actual sensor data to calculate residuals and identify developing faults [18,19,25,26].
Crucially, the 3D Multiphysics model developed in this study represents the offline physical foundation rather than a fully deployed real-time digital twin.
The results clarify the distinction between model validation and fault diagnosis. Validation establishes that the simulation reproduces measured behavior and generates plausible internal distributions under known conditions. Diagnosis requires the validated model to be applied repeatedly while operating conditions and component states change. In that stage, deviations should be evaluated as trends rather than isolated values because sensor noise, control actions, and environmental variation can temporarily alter the measured response. Combining voltage residuals with virtual indicators of oxygen availability, membrane hydration, and heat generation can reduce ambiguity and support classification of drying, flooding, starvation, or abnormal thermal loading. The voltage residual, which is the difference between the physical sensor data and the surrogate model’s baseline prediction, serves as the primary anomaly trigger. When an increased voltage residual coincides with virtually predicted high water concentration and low local oxygen fraction, it specifically identifies cathode flooding. Conversely, a voltage drop paired with low simulated membrane hydration and abnormal local heat generation clearly distinguishes membrane dehydration from standard operational load variations.

4. Discussion

This paper presented a validation-oriented PEMFC simulation study for future vehicle powertrain diagnostics. The investigated system is a 16 cm2 single-cell PEMFC measured with a Scribner 850 test system and modelled in COMSOL Multiphysics 6.1. Modelling data are presented in detail. Measured and simulated data showed good agreement, and the predicted species and heat concentrations interpret the laboratory results. The largest deviations occurred in the region of the activation losses and below the normal operating voltages, where the experimental curve showed less linear behavior. These observations support the hypothesis that an experimentally anchored high-fidelity Multiphysics model can serve as the reliable offline foundation for a later PEMFC diagnostic digital twin. Future work will focus on extracting fast-executing reduced-order models from this 3D framework and establishing the real-time data pipelines necessary for live vehicle diagnostics.
Future work should focus on the representation of the non-ideal catalyst and flow behavior, and extend the model to transient load cycles, stack-level validation, degradation tracking, and reduced-order real-time implementation.

Limitations and Challenges in Scaling to Stack and Vehicle Level Diagnostics

While the present study validates a high-fidelity 3D multi-physics model for a single-cell prototype under quasi-steady operating conditions, transferring this modelling framework to a full vehicle-level fuel cell stack introduces several physical and computational complexities that must be explicitly acknowledged:
Cell-to-Cell Variation: In a multi-cell stack (often comprising 100+ individual cells), manufacturing tolerances, localized contact-resistance variations, catalyst-layer degradation disparities, and clamping-pressure gradients cause significant non-uniformities among cells. A single-cell model inherently assumes ideal cell repeatability and cannot directly reflect localized cell failure or individual-cell voltage dispersion across a stack.
Manifold Flow Distribution: In stack configurations, reactants and coolants are distributed through long inlet and outlet headers (manifolds). Fluid dynamic losses, pressure drops, and two-phase flow phenomena within these manifolds lead to uneven reactant distribution among individual cells. Outer or downstream cells may experience localized oxygen or hydrogen starvation that is not present in a single-cell setup with uniform inlet boundary conditions.
Thermal Interactions and End-Plate Heat Loss: Unlike a single cell with controlled isothermal boundaries, stack thermal behavior is strongly coupled across adjacent cells. Heat transfer occurs via inter-cell conduction, internal coolant flow loops, and external convective/conductive heat losses through heavy end-plates. This creates substantial axial and radial thermal gradients along the stack core.
Balance of Plant (BoP) and Auxiliary Dynamics: In an actual Fuel Cell Electric Vehicle (FCEV) powertrain, cell performance is strictly governed by the dynamic response of auxiliary components. The mass flow, pressure, temperature, and relative humidity at the stack inlets depend on the time constants and transport delays of the air compressor, humidifiers, cooling pumps, throttle valves, and hydrogen ejectors/recirculation loops.
Transient Operation and Hysteresis: Vehicle driving cycles (such as WLTP or REAL-RDE transient profiles) involve millisecond-scale load transitions. Fast dynamic responses introduce transient phenomena, such as membrane hydration/dehydration hysteresis, dynamic liquid water accumulation, channel flooding purges, and dynamic oxygen starvation during rapid acceleration, which are not fully captured under steady-state or quasi-steady baseline conditions.

Author Contributions

Conceptualization, E.V. and J.K.; methodology, E.V.; software, J.K.; validation, J.K. and E.V.; formal analysis, E.V.; investigation, J.K.; resources, J.K.; data curation, J.K.; writing—original draft preparation, J.K.; writing—review and editing, E.V.; visualization, J.K.; supervision, E.V. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Data Availability Statement

The raw data supporting the conclusions of this article will be made available by the authors on request.

Acknowledgments

During the preparation of this manuscript, the authors used Google Gemini 3.6 Flash for the purpose of language editing and text refinement.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Wang, Y.; Chen, K.S.; Mishler, J.; Cho, S.C.; Adroher, X.C. A Review of Polymer Electrolyte Membrane Fuel Cells: Technology, Applications, and Needs on Fundamental Research. Appl. Energy 2011, 88, 981–1007. [Google Scholar] [CrossRef] [Scilit]
  2. Staffell, I.; Scamman, D.; Velazquez Abad, A.; Balcombe, P.; Dodds, P.E.; Ekins, P.; Shah, N.; Ward, K.R. The Role of Hydrogen and Fuel Cells in the Global Energy System. Energy Environ. Sci. 2019, 12, 463–491. [Google Scholar] [CrossRef] [Scilit]
  3. Springer, T.E.; Zawodzinski, T.A.; Gottesfeld, S. Polymer Electrolyte Fuel Cell Model. J. Electrochem. Soc. 1991, 138, 2334–2342. [Google Scholar] [CrossRef] [Scilit]
  4. NETL. Seventh Edition Fuel Cell Handbook; NETL: Pittsburgh, PA, USA; Morgantown, WV, USA, 2004. [Google Scholar]
  5. Wang, C.-Y. Fundamental Models for Fuel Cell Engineering. Chem. Rev. 2004, 104, 4727–4766. [Google Scholar] [CrossRef] [Scilit]
  6. Weber, A.Z.; Newman, J. Modeling Transport in Polymer-Electrolyte Fuel Cells. Chem. Rev. 2004, 104, 4679–4726. [Google Scholar] [CrossRef] [Scilit]
  7. Owejan, J.P.; Gagliardo, J.J.; Sergi, J.M.; Kandlikar, S.G.; Trabold, T.A. Water Management Studies in PEM Fuel Cells, Part I: Fuel Cell Design and in Situ Water Distributions. Int. J. Hydrogen Energy 2009, 34, 3436–3444. [Google Scholar] [CrossRef] [Scilit]
  8. Jiao, K.; Li, X. Water Transport in Polymer Electrolyte Membrane Fuel Cells. Prog. Energy Combust. Sci. 2011, 37, 221–291. [Google Scholar] [CrossRef] [Scilit]
  9. Li, X.; Sabir, I. Review of Bipolar Plates in PEM Fuel Cells: Flow-Field Designs. Int. J. Hydrogen Energy 2005, 30, 359–371. [Google Scholar] [CrossRef] [Scilit]
  10. Manso, A.P.; Marzo, F.F.; Barranco, J.; Garikano, X.; Garmendia Mujika, M. Influence of Geometric Parameters of the Flow Fields on the Performance of a PEM Fuel Cell. A Review. Int. J. Hydrogen Energy 2012, 37, 15256–15287. [Google Scholar] [CrossRef] [Scilit]
  11. Kritzinger, W.; Karner, M.; Traar, G.; Henjes, J.; Sihn, W. Digital Twin in Manufacturing: A Categorical Literature Review and Classification. IFAC-PapersOnLine 2018, 51, 1016–1022. [Google Scholar] [CrossRef] [Scilit]
  12. Fuller, A.; Fan, Z.; Day, C.; Barlow, C. Digital Twin: Enabling Technologies, Challenges and Open Research. IEEE Access 2020, 8, 108952–108971. [Google Scholar] [CrossRef] [Scilit]
  13. Jouin, M.; Gouriveau, R.; Hissel, D.; Péra, M.-C.; Zerhouni, N. Prognostics and Health Management of PEMFC—State of the Art and Remaining Challenges. Int. J. Hydrogen Energy 2013, 38, 15307–15317. [Google Scholar] [CrossRef] [Scilit]
  14. Liu, M.; Fang, S.; Dong, H.; Xu, C. Review of Digital Twin about Concepts, Technologies, and Industrial Applications. J. Manuf. Syst. 2021, 58, 346–361. [Google Scholar] [CrossRef] [Scilit]
  15. Guo, Y.; Zhou, Y.; Ma, R.; Xie, R.; Bai, H.; Jiang, W.; Ma, R. Synergistic Optimization of Fuel Economy and Durability in Fuel Cell Vehicles through Integrated Electro-Thermal Control. Green Energy Intell. Transp. 2026, 100449. [Google Scholar] [CrossRef] [Scilit]
  16. Wang, Y.; Yang, X.; Soo, Y.-Y.; Ameer, H.; Sun, Z.; Chen, Z. A Dual-Channel Predictive Framework for Fuel Cell Degradation Based on Adaptive Extended Kalman Filter and Optimized Random Forest. Green Energy Intell. Transp. 2026, 5, 100407. [Google Scholar] [CrossRef] [Scilit]
  17. Wu, H.; Fan, F.; Hao, W.; Song, K.; Xue, R.; Jiang, J.; Sun, C.; Li, Y.; Xie, C.; Chan, S.H. Low-Frequency Consensus Knowledge Transfer in PEM Fuel Cells for Cross-Domain Online Voltage Degradation Prediction. Green Energy Intell. Transp. 2026, 100405. [Google Scholar] [CrossRef] [Scilit]
  18. Tao, F.; Zhang, H.; Liu, A.; Nee, A.Y.C. Digital Twin in Industry: State-of-the-Art. IEEE Trans. Ind. Inform. 2019, 15, 2405–2415. [Google Scholar] [CrossRef] [Scilit]
  19. Rasheed, A.; San, O.; Kvamsdal, T. Digital Twin: Values, Challenges and Enablers From a Modeling Perspective. IEEE Access 2020, 8, 21980–22012. [Google Scholar] [CrossRef] [Scilit]
  20. Varga, E.; Kelemen, J.; Kiss, E.; Kis, D.I.; Bata, A. Manufacturing Process of Laboratory Bipolar Plates Designed with Gas Flow Simulation. Period. Polytech. Mech. Eng. 2025, 69, 252–258. [Google Scholar] [CrossRef] [Scilit]
  21. Barbir, F. PEM Fuel Cells: Theory and Practice; Academic Press: Cambridge, MA, USA, 2013. [Google Scholar]
  22. Baschuk, J.J.; Li, X. A General Formulation for a Mathematical PEM Fuel Cell Model. J. Power Sources 2005, 142, 134–153. [Google Scholar] [CrossRef] [Scilit]
  23. Kandlikar, S.G.; Lu, Z. Thermal Management Issues in a PEMFC Stack—A Brief Review of Current Status. Appl. Therm. Eng. 2009, 29, 1276–1280. [Google Scholar] [CrossRef] [Scilit]
  24. Wu, J.; Yuan, X.Z.; Martin, J.J.; Wang, H.; Zhang, J.; Shen, J.; Wu, S.; Merida, W. A Review of PEM Fuel Cell Durability: Degradation Mechanisms and Mitigation Strategies. J. Power Sources 2008, 184, 104–119. [Google Scholar] [CrossRef] [Scilit]
  25. Pei, P.; Chen, H. Main Factors Affecting the Lifetime of Proton Exchange Membrane Fuel Cells in Vehicle Applications: A Review. Appl. Energy 2014, 125, 60–75. [Google Scholar] [CrossRef] [Scilit]
  26. Debe, M.K. Electrocatalyst Approaches and Challenges for Automotive Fuel Cells. Nature 2012, 486, 43–51. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.