Abstract
This review aims to synthesize current evidence-based protocols to guide clinicians toward predictable and durable adhesive cementation of glass-fiber posts in intraradicular dentin. Endodontically treated teeth (ETTs) frequently exhibit significant structural loss, requiring additional retention strategies, such as glass-fiber posts bonded with resin cements. Clinical outcomes depend on multiple factors, including adequate dentin substrate preparation, appropriate adhesive strategies, and precise cementation techniques. The presence of smear layer debris may compromise adhesion; therefore, effective cleaning protocols are essential to ensure a contaminant-free substrate. Surface treatments of glass-fiber posts may enhance chemical bonding by exposing glass fibers and improving silane coupling. The selection of resin cement systems must consider limitations related to light transmission, polymerization depth, and the adhesive strategy employed. Moisture control and proper solvent volatilization are critical to optimizing bond strength, as is the prevention of contamination during cement application. Techniques that minimize porosity improve cement homogeneity and reduce interfacial defects that may act as failure initiation sites. Furthermore, the choice of core build-up material plays an important role in restoration durability. Collectively, these considerations demonstrate the importance of material selection and clinical technique in achieving reliable adhesive cementation of glass-fiber posts.
1. Introduction
Endodontic treatment is routinely performed to preserve teeth affected by pulpal and periapical disease and represents an integral component of contemporary dental practice [1,2]. Depending on case complexity, treatment may be provided by general dental practitioners or endodontic specialists. Consequently, restoration of endodontically treated teeth is a frequent clinical challenge.
After endodontic treatment, restoring the tooth to reestablish function, esthetics, and structural integrity is essential for long-term clinical success. In addition to replacing lost tooth structure, the restorative procedure must prevent bacterial microinfiltration and reduce the risk of root fracture in teeth that are already structurally compromised. In endodontically treated teeth (ETTs) restored with glass-fiber posts, clinical success is primarily associated with three factors: preservation of remaining tooth structure [1,2], the presence of an adequate ferrule [3,4,5], and the effectiveness of the adhesive interface [6].
The ferrule effect is a major factor in the prognosis of endodontically treated teeth and refers to the circumferential wrapping of sound coronal tooth structure by the definitive restoration [3,4]. The presence of remaining coronal walls and an adequate ferrule improves resistance to functional loading and is generally considered more important for tooth survival than post placement itself [1,2,4]. Although a vertical ferrule height of approximately 1.5–2.0 mm is commonly advocated, clinical performance also depends on the circumferential continuity and thickness of the remaining dentin, tooth position, and loading conditions. Therefore, the placement of a post and core alone does not overcome the biomechanical limitations associated with inadequate sound tooth structure [3,4].
Surgical crown lengthening may be considered to expose additional sound tooth structure but can compromise periodontal support and the crown-to-root ratio. Orthodontic extrusion represents an alternative approach that can expose additional coronal tooth structure while limiting removal of supporting bone, although it requires additional treatment time and appropriate periodontal and orthodontic conditions. More information about such procedures can be found in Cordaro et al., 2021 [7].
Intraradicular post systems have evolved considerably over time. Cast metal post-and-core restorations and prefabricated metallic posts were previously used to provide retention for restorations in teeth with extensive coronal structure loss [6]. Subsequently, non-metallic post systems were introduced, including carbon-, quartz-, and glass-fiber-reinforced posts, with glass-fiber posts becoming widely used as an adhesive and esthetic alternative to metallic posts [6]. Their elastic properties are closer to those of dentin, contributing to a more favorable biomechanical behavior and reducing the occurrence of catastrophic root fractures compared with more rigid post systems [1,2,6].
Clinical evidence indicates that the most common failure mode of glass-fiber post restorations is debonding [8,9]. Because these posts are passively retained within the root canal, the predictability of the restorative outcome depends largely on the quality and precision of adhesive cementation procedures [6]. However, adhesive cementation within the root canal remains a challenging clinical task due to technique sensitivity and the complex characteristics of the intraradicular dentin substrate [10,11].
Factors such as root morphology, which strongly influences polymerization shrinkage due to the high cavity configuration factor (C-factor), limited light transmission for photopolymerization [11], challenges in moisture control [12], the incorporation of air bubbles into the cement layer [13], and the presence of debris from endodontic materials [6], when combined with cyclic occlusal forces that induce fatigue at the adhesive interface, may promote the initiation and propagation of defects generated during cementation and ultimately lead to post debonding [14]. In addition, the density and orientation of dentinal tubules vary along the root, while irrigants, endodontic sealers, gutta-percha remnants, and the secondary smear layer generated during post space preparation may interfere with adhesive interaction. These characteristics make adequate substrate conditioning and uniform adhesive application particularly technique-sensitive [6,11].
Conversely, clinical studies evaluating endodontically treated teeth restored with glass-fiber posts have reported success rates ranging from 70% to 90% after three years of follow-up [5,15]. However, achieving these outcomes is closely associated with adequate operator training and strict adherence to optimized clinical protocols, as greater technical and scientific knowledge is directly related to higher resin cement bond strength to dentin [16]. Although adhesive cementation is a technically demanding procedure, resin cement has undergone the greatest technological evolution in recent decades. Resin cements are composite resins with a lower filler content, which provides greater flowability and ensures a thin cement film thickness [17]. These materials offer several advantages over conventional cements, including higher compressive, flexural, and tensile strength [18].
At the substrate level, dentin should also be considered as a dynamic tissue whose mechanical properties are influenced by changes in mineral content. Demineralization exposes the collagen-rich organic matrix and modifies tissue stiffness, whereas remineralization can partially restore mineral content and mechanical integrity. These processes are particularly relevant to adhesive dentistry because contemporary bonding strategies intentionally modify the mineral phase of dentin to enable micromechanical and chemical interaction with resin-based materials [19].
Although numerous studies have investigated individual factors affecting glass-fiber post retention, the available evidence remains fragmented. In this context, a comprehensive understanding of the biological, mechanical, and material-related variables involved in adhesive cementation of glass-fiber posts is essential for improving clinical predictability and long-term outcomes. Therefore, this narrative review aims to synthesize current evidence regarding the factors influencing adhesive cementation of glass-fiber posts in intraradicular dentin. The objective is to provide clinically relevant recommendations to support predictable and durable restorative outcomes in endodontically treated teeth.
2. Literature Search
A structured literature search was performed to identify relevant evidence on adhesive cementation of glass-fiber posts. PubMed/MEDLINE, Scopus, and Web of Science were searched using combinations of terms related to “fiber post”, “glass fiber post”, “root dentin”, “resin cement”, “bond strength”, “surface treatment”, “endodontic sealer”, “cement porosity”, “CAD/CAM post”, and “customized fiber post”. The literature search was last updated on 31 August 2026. Clinical studies, laboratory investigations, systematic reviews, and meta-analyses relevant to the scope of the review were considered. Because much of the available evidence is derived from laboratory studies, findings from in vitro investigations were interpreted as mechanistic evidence and were not directly extrapolated to clinical outcomes.
3. Adhesion Components
To understand adhesive procedures, it is essential to recognize that adhesion involves three fundamental components [17]:
- (a)
- Adhesive: A substance capable of promoting bonding, such as silane, the adhesive system, or the cement itself.
- (b)
- Adherents: The surfaces of the materials to be bonded (substrates), such as dentin, enamel, ceramic, post surface, or composite resin.
- (c)
- Adhesive interface: The region where the adhesive comes into contact with the adherent substrate.
Adhesion may occur through mechanical mechanisms, such as micromechanical interlocking of the polymerized adhesive within dentinal tubules and collagen fibril networks [20]; physical interactions resulting from close surface contact that enable secondary bonds, including hydrogen bonding and van der Waals forces, as observed with increased surface wettability after silane application; and primary chemical bonds, such as covalent, ionic, or metallic bonds involving electron sharing between atoms. Examples include covalent bonding between silane and the organic matrix of resin cement [17], ionic bonding between phosphate groups of 10-MDP monomers and calcium ions in hydroxyapatite [21], and metallic bonding occurring during welding processes [17]. In dentistry, adhesion may result from one or a combination of these mechanisms [22].
The success of any adhesive procedure depends on the long-term integrity of the adhesive interface. Achieving this outcome requires proper handling of both adhesive materials and adherent surfaces. Accordingly, the adhesive cementation technique can be divided into three main stages: (1) preparation of adherent surface A; (2) preparation of adherent surface B; and (3) cementation.
Specifically, the cementation of intraradicular posts, whether metallic or prefabricated fiber-reinforced posts, follows these stages: (1) preparation of the root dentin surface; (2) post surface preparation; and (3) cementation.
4. Post Space Preparation
Once the clinical and radiographic evaluation of the endodontically treated tooth (ETT) is completed, a diagnosis is established, and the need for an intraradicular post is determined. The remaining coronal structure should initially be prepared by removing residual carious tissue, regularizing the tooth surface, and eliminating unsupported tooth structure with a thickness of less than 1 mm [23] (Figure 1a,b).
Figure 1.
Schematic drawing of the phases of dental substrate preparation. (a) Evaluation of the remaining structure; (b) X-ray after preparation of the coronal remnant; (c) post selection; (d) absolute isolation of the operative field; (e) removal of gutta-percha; (f) preparation for post placement; (g) evaluation of the prepared root walls; (h) chemical cleaning of debris from the dentin walls.
Subsequently, the post diameter is selected either by superimposing a manufacturer-provided post selection chart onto the initial radiograph or by using drills specific to the selected post system (Figure 1c). The diameter of the chosen post should not exceed one or two sizes larger than the last file used during endodontic treatment, and the intraradicular length must preserve an apical seal of 4–5 mm of gutta-percha [24].
After post selection, rubber dam isolation is mandatory (Figure 1d). This step is essential because contamination with saliva, blood, or crevicular fluid can significantly compromise the longevity of the adhesive interface [25,26]. Furthermore, as these procedures are performed within the root canal, rubber dam isolation also prevents salivary and bacterial contamination, accidental ingestion of instruments, and leakage of irrigating solutions into the oral cavity [27].
Following isolation, partial removal of the root canal filling material is performed using Gates–Glidden drills, Wide tips, or heated Rhein tips slightly narrower than the canal diameter. This step establishes an appropriate trajectory for subsequent canal preparation with the manufacturer’s drills and reduces the risk of perforation (Figure 1e).
For post space preparation, drills recommended by the manufacturer of each prefabricated post system should be used, as they are designed according to the specific diameter and morphology of the post (Figure 1f). This approach is critical because the prepared root canal exhibits a high cavity configuration factor (C-factor). Increased cement film thickness resulting from post maladaptation leads to greater polymerization contraction stress and a higher risk of debonding at the cement–dentin interface [28]. In addition, accurate post adaptation to the canal walls improves retention and promotes more uniform stress distribution at the adhesive interface, thereby reducing the likelihood of failure [29].
In anatomically enlarged or irregular root canals, prefabricated posts may present limited adaptation, resulting in an increased cement-layer thickness [30]. Customized fiber posts and CAD/CAM-milled glass-fiber posts have therefore been proposed to improve adaptation to root canal geometry [31]. A recent systematic review and meta-analysis reported that CAD/CAM-milled glass-fiber posts exhibited higher fracture strength and bond strength and lower cement-layer thickness than prefabricated glass-fiber posts, whereas their fracture and bond strength were similar to those of customized glass-fiber posts [32]. However, the included evidence was predominantly laboratory-based and showed substantial heterogeneity [32]; therefore, these findings should not be directly interpreted as evidence of superior clinical longevity.
5. Preparation of the Root Dentin Surface
During preparation of the root canal to receive an intraradicular post, part of the dentin previously altered by irrigating solutions, intracanal medications, and endodontic sealers may be removed. However, rotary instrumentation within the root canal produces a thick secondary smear layer composed of dentin remnants, plasticized gutta-percha, and endodontic cement adhered to the canal walls [6].
For effective interaction between the adherent surface, in this case, root dentin, and the adhesive material, the substrate must be clean and have adequate control of contamination that may interfere with bonding [33]. In this context, debris remaining after post space preparation can directly compromise intraradicular post cementation, as the smear layer may obliterate dentinal tubules and hinder the penetration of adhesive systems and resin cements. Consequently, the bond strength between the resin cement and the root canal walls may be reduced [34].
Several studies have evaluated how chemical cleaning methods for smear layer removal affect the bond strength of resin cements to root dentin [35,36,37,38,39,40,41]. Evidence indicates that the effectiveness of cleaning protocols depends on the cementation strategy employed, namely whether etch-and-rinse, self-etch, or self-adhesive cements are used [40]. A recent meta-analysis demonstrated that, for cementation protocols requiring prior dentin conditioning with phosphoric acid, sodium hypochlorite at low concentrations of 1%, 2%, and 2.5% shows an 83.4% probability of being the most effective cleaning agent [40].
Importantly, the smear layer should not be regarded as uniformly adverse because its role depends on the adhesive strategy [21]. Etch-and-rinse systems remove the smear layer through acid conditioning, whereas self-etch systems modify and incorporate it into the adhesive interface. Self-adhesive resin cements interact more superficially with the underlying dentin and rely partly on chemical interaction between functional acidic monomers and hydroxyapatite.
Sodium hypochlorite exhibits antimicrobial activity and a high capacity to dissolve organic tissues, debris, and endodontic sealer residues. At low concentrations, it does not adversely affect adhesion [40]. For self-etch and self-adhesive cementation strategies, ethyl alcohol at concentrations of 70% and 90% presents approximately a 75% probability of being the most effective cleaning agent [40]. Ethanol can replace water within dentin, prevent collagen matrix collapse, and promote collagen fibril shrinkage, which may enhance infiltration of hydrophobic monomers and result in higher bond strength values [42].
Although the scientific literature does not conclusively establish an optimal cleaning solution, the protocols described above do not negatively affect the bonding of resin cements to root dentin. Nevertheless, surfaces contaminated with debris impair adhesion. Therefore, final irrigation of the canal after post space preparation is mandatory, even if performed only with distilled water, using a syringe and endodontic irrigation cannulas to remove residual debris (Figure 1h and Figure 2).
Figure 2.
Example of irrigation with distilled water using a syringe and endodontic irrigation cannulas for removal of residual debris.
More recently, chitosan has been investigated as an alternative root-dentin pretreatment. In an in vitro study, pretreatment with 2.5% chitosan increased the push-out bond strength of fiber posts cemented with a self-adhesive resin cement compared with the untreated control, whereas 1% chitosan and 17% EDTA did not produce a significant improvement. These findings suggest that the effect of chemical pretreatment may be concentration- and material-dependent; however, clinical confirmation is still required [43].
The type of endodontic sealer may also influence the subsequent bonding of fiber posts because sealer residues can remain on root dentin after post space preparation [44,45,46]. Recent laboratory studies evaluating epoxy resin-based and calcium silicate-based sealers have reported material-dependent results, with some combinations of epoxy resin-based sealers and conventional resin cements showing higher bond strength, whereas other studies found no significant effect of sealer type. A recent systematic review of in vitro studies generally reported higher bond strength with resin-based sealers than with eugenol-based sealers, while the evidence for bioceramic sealers remained inconsistent. Therefore, the interaction among sealer composition, cleaning protocol, and cementation strategy should be considered, although the available evidence cannot yet establish definitive clinical recommendations [44,45,46].
6. Post Surface Preparation
Various surface treatments have been investigated to optimize adhesion between glass-fiber posts and resin cements. Among the treatments that have demonstrated favorable results are airborne-particle abrasion with silica-coated aluminum oxide (silicatization) and conditioning with hydrogen peroxide (H2O2). These treatments aim to expose glass fibers, thereby enhancing chemical bonding with silane agents.
The function of silane is to increase the wettability of the post surface and promote chemical bonding between the methacrylate groups present in the resin cement and the hydroxyl groups of the glass fibers [6]. In this context, the scientific literature has shown that combining silane with one of these pretreatments is advantageous for increasing adhesion between the cement and the post [47].
Silica-coated aluminum oxide (Al2O3) airborne-particle abrasion is a tribochemical treatment (CoJet, 3M ESPE) commonly used to increase the adhesiveness of acid-resistant ceramics. This system creates micromechanical retention on the material surface through abrasion caused by silica-modified Al2O3 particles with a grain size of 30 μm. In addition to micromechanical retention, a silica layer forms on the post surface due to the high temperature generated by the blasting pressure, making the surface more chemically reactive to silane application [48].
Another promising procedure is conditioning with hydrogen peroxide (H2O2), as it is a simple and effective method that uses materials commonly available in dental offices, such as hydrogen peroxide bleaching gels. The described protocol involves applying 24% H2O2 to the post surface for 1 min, followed by silane application [49,50]. The mechanism of action of this technique relies on hydrogen peroxide’s ability to dissolve the superficial epoxy resin matrix of the post, thereby exposing a larger surface area of glass fibers for silanization without damaging them. Additionally, the spaces created between fibers provide extra sites for micromechanical retention of the resin cement [51].
Although these pretreatments have shown positive results [6,51,52,53], further studies are necessary to establish a definitive clinical protocol [53], allowing for their routine inclusion based on clinician preference. Nevertheless, to avoid contamination resulting from post manipulation, surface cleaning is recommended. This cleaning can be performed using 70% ethanol or 37% phosphoric acid for 30 s; in this context, these agents act solely as cleaning solutions before silanization and not as bond-strength-enhancing agents [37].
Laser irradiation has also been investigated as an alternative surface-conditioning approach. An in vitro study comparing Er: YAG laser irradiation with silanization alone, hydrogen peroxide treatment, and airborne-particle abrasion reported the highest push-out bond strength after Er: YAG laser treatment followed by silanization [54]. Another study reported that Er: YAG laser irradiation did not demonstrate a significant improvement in the pull-out bond strength of glass-fiber posts [55]. Therefore, these findings indicate that laser irradiation may modify the post surface; however, the evidence remains controversial and laboratory-based and does not yet support its routine clinical use [54].
Based on the above considerations, after preparing the root canal to receive the post, a trial fitting of the post is performed (Figure 3a). This trial must be completed before any surface treatment of the post, as contact with any surface other than the resin cement already placed in the canal should be avoided after silanization. Following the trial, the post surface may be cleaned using 37% phosphoric acid and/or cotton or gauze soaked in 70% ethanol (Figure 3b,c). Given its simplicity and availability in clinical practice, conditioning with 24% hydrogen peroxide for 1 min is recommended (Figure 3d), followed by application of the silane coupling agent (Figure 3e) and gentle air drying to volatilize the solvent (Figure 3f).
Figure 3.
Schematic drawing of the stages of post preparation. (a) Final moment of the test; (b) cleaning with 37% phosphoric acid for 30 s; (c) cleaning with alcohol; (d) conditioning with 24% H2O2 for 1 min; (e) silanization; (f) volatilization of the silane solvent.
7. Cementation Systems
The selection of the cementation system and the preparation of the dentin substrate depend on the specific requirements of each clinical situation, including ceramic veneers, full crowns, inlays, onlays, and intraradicular posts [56]. An important classification for selecting a cementing agent for intraradicular posts is based on the mode of polymerization:
- (a)
- Chemically activated cements:
These materials are typically supplied in a paste–paste form. The catalyst paste contains a chemical co-initiator, such as a tertiary amine, whereas the base paste contains an activator, such as benzoyl peroxide. When mixed, these components react to initiate polymerization [56]. Some cements in this category also include photoinitiators; however, polymerization occurs predominantly through chemical activation [18].
- (b)
- Photoactivated cements:
In these systems, polymerization occurs through the activation of photoinitiators, such as camphorquinone, which react with an aliphatic amine to generate free radicals that initiate the polymerization process [56].
- (c)
- Dual-cure cements:
These cements are also supplied in a paste–paste form. In dual-cure systems, polymerization begins through light activation of photoinitiators and proceeds simultaneously through chemically generated activation resulting from the reaction between an activator and a co-initiator [56]. Although they contain chemical initiators, light activation remains necessary to achieve an adequate degree of conversion [18].
Limited light access within the root canal, as well as light attenuation caused by the presence of the post, even when translucent, compromises the photopolymerization of both the adhesive system and the resin cement. Therefore, chemically activated and dual-cure cementation systems are recommended for intraradicular posts [57,58]. An additional advantage of chemically activated polymerization is the reduction in polymerization shrinkage stress at the adhesive interface [6].
Another relevant classification of resin cement systems is based on the recommended adhesive strategy, defined by the sequence of dentin substrate preparation (Table 1, Figure 4):
Table 1.
Classification of representative resin cement systems according to the adhesive strategy recommended by their respective manufacturers and their indication for core build-up. Product-specific information was obtained from the manufacturers’ instructions for use available at the time of manuscript preparation.
Figure 4.
Schematic drawing of the step-by-step protocol for each adhesive strategy. (a) Resin cement systems with prior acid conditioning; (b) self-conditioning resin systems; (c) self-adhesive resin cement systems. The step-by-step procedure is described in Table 2.
- (a)
- Etch-and-rinse cements:
This adhesion strategy begins with phosphoric acid etching of dentin to remove the smear layer produced during post space preparation, demineralize the dentin surface, expose collagen fibrils, and increase the diameter of dentinal tubules. Subsequently, the adhesive system infiltrates the collagen network and dentinal tubules, and after polymerization, micromechanical retention is achieved through the formation of a hybrid layer [59].
- (b)
- Self-etching cements:
These cements do not require separate phosphoric acid etching. Instead, they employ self-conditioning primers that partially demineralize the smear layer while simultaneously infiltrating the dentin substrate, theoretically ensuring complete penetration of the adhesive system. During infiltration, acidic monomers lose their acidity through interaction with the mineral content of dentin, thereby reducing their ability to further condition the substrate [21].
- (c)
- Self-adhesive cements:
These cements do not require prior preparation of the dentin surface. Their adhesive properties are based on acidic monomers present in their formulation, which simultaneously demineralize and infiltrate the dentin substrate, creating micromechanical retention and chemical bonds with hydroxyapatite. Moisture within the dentin matrix promotes ionization of residual acidic monomers, leading to their neutralization and transformation into a hydrophobic material with neutral pH values [60].
The rationale for self-etch and self-adhesive systems is based on the principle of simultaneous dentin demineralization and infiltration by methacrylate monomers. The adhesion mechanism of these systems also involves additional chemical bonding to tooth structures [59]. However, the thickness of the hybrid layer varies according to the system used, being thicker in etch-and-rinse systems, 5–7 μm [61], thinner in self-etch systems, 0–2 μm [62], and absent in self-adhesive cements [63].
In this context, etch-and-rinse cements have demonstrated consistent effectiveness and validation for the cementation of glass-fiber intraradicular posts [6,64]. Phosphoric acid etching removes the smear layer and promotes the formation of a thicker hybrid layer, increasing adhesive retention to dentin [64,65], particularly when three-step adhesive systems are employed [6]. However, achieving reliable bond strength depends on the precise execution of each clinical step, which may be challenging due to the greater number of procedural stages involved (Figure 4; Table 2) and the consequent increased risk of technical errors. In addition, these systems are highly sensitive to dentin moisture control and proper adhesive infiltration within the root canal [59,60,66].
Adhesive systems may also be classified according to the number of clinical steps. Conventional three-step etch-and-rinse systems require separate phosphoric acid conditioning, primer, and adhesive resin application, whereas simplified etch-and-rinse systems combine the primer and adhesive components after an etching step [59]. Self-etch systems eliminate separate phosphoric acid conditioning and may involve a self-etching primer followed by an adhesive resin or combine the conditioning, priming, and bonding functions into a simplified application [21]. Although simplified systems reduce the number of steps, their interaction with the dentin substrate and compatibility with the resin cements must be considered [20,21,50,62,63,64,65].
Moisture control represents a challenge in coronal dentin bonding and becomes even more critical during the cementation of intraradicular posts. To reduce technique sensitivity, manufacturers have developed simplified adhesive systems. Consequently, cementation strategies with fewer procedural steps, such as self-etch and self-adhesive systems, have been introduced. Self-etch systems are supplied with acidic primers that must be applied to dentin before cementation. However, their use in root canals is more complex than that of self-adhesive cements due to difficulties related to solvent evaporation, removal of excess adhesive, and control of application [60].
When the etch-and-rinse strategy is selected, strict control of dentin moisture is required. The canal should not be excessively wet, which may dilute or solubilize the adhesive, nor overly dry, which may cause collapse of the collagen fibril network. A controlled level of moisture is necessary to allow for adequate penetration of adhesive monomers into the collagen network and dentinal tubules [67]. Therefore, after acid etching, moisture removal using absorbent paper points is recommended until no visible moisture remains (Figure 4; Table 2). The same procedure is indicated after canal irrigation and before application of acidic primers when self-etch cements are used.
Table 2.
Clinical sequence and number of steps according to the adhesive strategies illustrated in Figure 3. The strategies are described in the table as: (a) previous acid etching; (b) self-conditioning; (c) self-adhesive [21,59,60,62,63,64,65,68,69,70,71].
The method of adhesive application within the canal also influences bond strength. Improved outcomes have been reported when extra-fine microbrushes or applicators specifically designed for root canals are used [68]. In etch-and-rinse systems, adhesive application should be gentle and cover all dentinal walls. In self-etch systems, active application over the entire surface for at least 20 s is recommended (Figure 4).
After adhesive application, solvent evaporation is essential to optimize bond strength [69]. Residual solvent may dilute adhesive monomers during hybrid layer formation [70]. The application of an oil- and water-free air jet from a triple syringe for approximately 20 s, positioned about 1 cm from the canal entrance, is effective for solvent volatilization [70]. In addition, combining air application with absorbent paper points assists in removing excess adhesive that may accumulate in the apical region [68,71].
In this review, resin cements and adhesive systems are considered integrated systems. Although some two-bottle adhesive systems from different manufacturers may contain similar components, mixing products from different brands is not recommended. This recommendation also applies to cementation agents. Studies have demonstrated incompatibilities between dual-cure or chemically activated cements and simplified adhesive systems, including etch-and-rinse adhesives and single-bottle self-etch adhesives [72,73,74,75]. Although some contemporary systems claim cross-brand compatibility, clinicians should always follow the manufacturer’s instructions. Table 1 classifies resin cements according to their recommended adhesive strategy and corresponding adhesive system.
Dentin surface treatment is a critical and technique-sensitive step that significantly influences cementation success. In this context, self-adhesive resin cements are less sensitive to moisture because they eliminate the need for acid etching and separate adhesive application [60]. Scientific evidence indicates that self-adhesive cements interact superficially with dentin [62]. Therefore, the presence of functional monomers such as phosphates and carboxylates, which chemically interact with hydroxyapatite, makes chemical adhesion a predominant bonding mechanism in these materials [62].
One study evaluated the influence of operator experience, comparing dentists and dental students, on bond strength using three cementation strategies: etch-and-rinse with a two-bottle adhesive system, etch-and-rinse with a one-bottle adhesive system, and self-adhesive cement. Higher bond strength values were observed among experienced dentists; however, when self-adhesive cement was used, operator experience did not influence the results [16]. These findings suggest that reducing the number of procedural steps is an important factor for achieving reliable adhesion regardless of operator experience [16].
Conversely, a clinical study reported that the success rate of teeth restored with glass-fiber intraradicular posts is not influenced by the adhesive strategy employed [5]. It should be noted, however, that such studies are conducted under controlled conditions by experienced and calibrated operators. Therefore, considering the advantages and limitations of each system, the selection of a resin cement should be based on clinical judgment, balancing predictability, technique sensitivity, and cost–benefit considerations.
Regarding bond strength, recent higher-level evidence has compared conventional and self-adhesive approaches for glass-fiber post cementation. A 2025 systematic review and meta-analysis found that cement category can influence bond-strength outcomes, although considerable methodological variability among laboratory studies should be considered when interpreting these findings. Therefore, selection of the cementation strategy should account not only for bond-strength performance but also for substrate condition and technique sensitivity [76].
Once the adhesive cementation system has been selected, the clinician must deliver the cement into the root canal. At this stage, the insertion method should ensure a homogeneous cement layer free of bubbles, voids, and porosities, as these defects may compromise the integrity of the adhesive interface.
This requirement is particularly relevant because most clinical failures in dentistry are associated with fatigue mechanisms. In these situations, fracture or debonding of the restorative material and/or the adhesive interface occurs as a result of crack initiation, propagation, and coalescence under cyclic loading and in the presence of moisture [77,78]. Failure typically originates from pre-existing defects within the material, such as cracks, pores, inclusions, or voids.
Porosities and air bubbles within the cement layer may form depending on the technique used to introduce the cement into the root canal, significantly compromising the adhesive bond strength to dentin [13,79,80,81]. Defects within the cement line and at the adhesive interface can negatively affect adhesion longevity through several mechanisms [80,81,82,83]:
- (I)
- Bubbles at the interface reduce the effective contact area between cement and dentin.
- (II)
- The mechanical properties of restorative materials are highly sensitive to structural defects. As stress concentration sites, defects within the cement layer or adhesive interface may initiate and propagate cracks, ultimately leading to fracture or debonding.
- (III)
- Air bubbles act as stress concentrators, generating higher stress peaks at the adhesive interface.
Resin cement may be introduced into the root canal using several techniques, including lentulo spirals, endodontic files, explorer probes, direct application onto the intraradicular post, or delivery into the canal using a Centrix-type syringe. Currently, some manufacturers also provide resin cements in syringes equipped with self-mixing tips (Figure 5 and Figure 6).
Figure 5.
Cement can be introduced into the root canal using a Centrix-type syringe.
Figure 6.
Schematic drawing of the correct and incorrect methods for cement insertion. (a) Cement can be applied using a lentulo spiral, Centrix syringe, or self-mixing tip. Applications should proceed from apical to cervical. (b) Methods not recommended due to the high likelihood of defects in the cement line: use of an explorer probe, endodontic file, or direct application on the post should be avoided.
Studies have demonstrated that the use of endodontic application syringes, such as Centrix systems, produces cementation lines with significantly fewer porosities [13,79,80,83]. Self-mixing tips further reduce porosity by allowing the base and catalyst pastes to mix within the tip without air exposure, thereby minimizing bubble incorporation [79,80]. Recent micro-CT evidence further supports the relevance of cement-layer characteristics, demonstrating that post design and cement type can affect cement thickness, apical voids, and post retention. These findings reinforce that adaptation and cement-layer quality should be considered together rather than evaluating only resin cement composition [84].
The use of lentulo spirals may also reduce porosity inclusion; however, this technique can generate heat, accelerate resin cement polymerization, and reduce working time [65], potentially compromising accurate positioning of intraradicular posts [85]. In contrast, cement application using endodontic files, explorer probes, or direct placement onto the post has been associated with a higher incidence of defects within the cement layer and adhesive interface [13,79,80,81], as illustrated in Figure 6. For this reason, these techniques are considered less appropriate.
To minimize porosity formation, resin cement should be delivered using syringes equipped with endodontic tips, including Centrix or self-mixing systems. The cement should be injected from the apical toward the cervical direction, allowing for slight extrusion at the canal entrance. Subsequently, the intraradicular post is inserted, excess cement is removed, and light activation is performed according to the manufacturer’s instructions (Figure 6).
8. Core Building
The restoration of endodontically treated teeth represents a clinical challenge, as these teeth have usually undergone substantial loss of tooth structure. Reconstruction may therefore be performed using either a direct technique with composite resin or an indirect technique employing ceramics or indirect composite resins.
Direct reconstruction can be performed using bulk-fill or conventional composite resins [86] and is indicated when the loss of tooth structure is limited and the cavity configuration allows for adequate re-establishment of proximal contact and contour [87].
When an indirect restoration is planned, it is necessary to fabricate a core buildup to provide retention and support for the prosthetic restoration. Because glass-fiber posts are relatively flexible, the core material must present sufficient mechanical strength to withstand multidirectional masticatory forces, as well as the stresses generated by high-speed rotary instruments during coronal preparation [88].
Although resin cements have a composition similar to that of composite resins, their mechanical properties (such as flexural strength and elastic modulus) are inferior. Therefore, they are not recommended for core buildup fabrication. In the case of self-adhesive resin cements, additional consideration must be given to their hydrophilic monomers, which are necessary for dentin conditioning. These monomers increase water sorption, potentially leading to hygroscopic expansion of the core buildup. Even when the definitive restoration is a full crown, water may reach the core material through diffusion across the cement layer [89]. Hygroscopic expansion may induce microcracks within the core structure and the restoration, thereby compromising clinical success [90,91,92]. Glass ionomer-based materials, including resin-modified glass ionomers, should also be avoided due to their hydrophilic nature [92,93].
High-viscosity conventional and bulk-fill composite resins are among the most suitable materials for core buildup fabrication. Bulk-fill composites allow for placement of thicker increments, reducing clinical time and technique sensitivity, making them particularly advantageous in teeth with extensive coronal destruction. Conversely, flowable composite resins facilitate closer adaptation to the post surface and reduce the formation of bubbles and gaps at the post–core interface [94].
Currently, flowable composites specifically indicated for core buildup fabrication are available (Table 1). These materials exhibit higher filler content than resin cements and, consequently, superior mechanical properties. As filler content increases, elastic modulus and flexural strength also increase, resulting in improved fracture resistance of the final restoration [88,91]. Moreover, a higher elastic modulus of the core material enhances the strength of the overlying ceramic restoration [95]. Many of these materials exhibit dual polymerization, allowing for their use as both cementing agents and core materials [88]. The use of a single material with mechanical properties suitable for both purposes simplifies the operative procedure and reduces clinical time [96].
Another factor to consider is the incompatibility between self-etch adhesive systems and chemically activated or dual-cure cements. This incompatibility arises from acidic monomers present in self-etch adhesives, which may inhibit the polymerization of dual-cure cements. Therefore, adherence to manufacturer recommendations is essential [97].
The timing of post cutting may also influence the bond strength between the cement and root dentin. Vibrations generated during the cutting of a recently cemented post may induce stresses at the adhesive interface, potentially leading to debonding and reduced adhesive longevity [98]. Consequently, post cutting should not be performed immediately after cementation. Preferably, post silanization and cutting should be completed during the trial-fitting phase. Alternatively, post cutting may be performed after core buildup fabrication, as the core material can act as a stress-absorbing shield during cutting procedures [98].
Fiber-reinforced composite resins have been increasingly indicated as core build-up materials in endodontically treated teeth with extensive coronal loss, particularly when conventional particulate composites may not provide adequate fracture resistance or stress dissipation [99,100,101,102,103,104,105,106]. Experimental and clinical evidence consistently demonstrates that the incorporation of short or discontinuous glass fibers within a resin matrix enhances fracture toughness, flexural strength, and crack-propagation resistance through crack-bridging and stress-transfer mechanisms, promoting biomechanical behavior closer to dentin and reducing catastrophic failure patterns [99,100,101,102,103]. Systematic reviews further report superior load-bearing capacity and more favorable fracture modes when compared with non-reinforced composites, although values remain lower than those of intact teeth [104,105]. Additional studies indicate that interfacial optimization and appropriate fiber orientation significantly influence mechanical performance, highlighting the technique sensitivity and potential anisotropy of these materials [102,106]. Limitations include higher cost, finishing complexity, and dependence on correct handling. When compared with conventional and bulk-fill composites, fiber-reinforced systems generally demonstrate improved fracture performance, yet clinical indication should remain guided by balanced evidence-based judgment [100,102].
In summary, after post cementation, the core buildup may be fabricated using flowable, conventional, or bulk-fill composite resins, provided they possess mechanical properties suitable for high-masticatory-load conditions. Materials with high filler content and an elastic modulus between 10 and 25 GPa are recommended. Resin cements should generally not be used for core buildup fabrication due to their inadequate mechanical properties and potential for hygroscopic expansion, unless specifically designed for this purpose. Post cutting may be performed before cementation during the trial phase or after core buildup fabrication (Figure 7), depending on the chosen clinical protocol.
Figure 7.
Core build-up performed with fiber-reinforced composite before intraradicular post trimming and preparation.
This narrative review has limitations due to its design. Unlike a systematic review, the literature search and study selection were not conducted according to a predefined systematic protocol; therefore, relevant studies may not have been identified or included. In addition, the available evidence encompasses heterogeneous materials, adhesive systems, experimental methods, and outcome measures, limiting direct comparisons among studies. A substantial proportion of the evidence regarding intraradicular adhesion is derived from in-vitro investigations, and these findings should therefore be interpreted cautiously when translated into clinical recommendations.
9. Conclusions
Adhesive cementation of glass-fiber posts in intraradicular dentin requires careful consideration of several interrelated factors. Effective root-dentin pretreatment is essential to minimize the adverse effects of smear layer debris and residual endodontic materials on adhesion. Appropriate post surface conditioning may improve the interaction between glass-fiber posts and resin cements, although its effectiveness depends on the treatment protocol and post composition. The selection of adhesive systems and resin cements should account for the characteristics of the root canal, particularly limited light transmission, polymerization conditions, and moisture control. Adequate post adaptation and careful cement insertion techniques are important for minimizing cement thickness, porosity, and interfacial defects. Customized and CAD/CAM-fabricated glass-fiber posts represent promising alternatives for improving post adaptation, although their long-term clinical advantages remain insufficiently established. Overall, successful adhesive cementation depends on the combined optimization of substrate preparation, material selection, and clinical procedures rather than any single intervention. Nevertheless, clinical decisions should prioritize established protocols supported by clinical evidence, while emerging techniques require further validation through well-designed longitudinal clinical studies.
Author Contributions
Conceptualization, G.S.d.A., M.G.A., C.T.R.H., C.E.F. and J.P.M.T.; methodology, G.S.d.A. and M.G.A.; investigation, G.S.d.A. and M.G.A.; writing—original draft preparation, G.S.d.A. and M.G.A.; writing—review and editing, G.S.d.A., M.G.A., C.T.R.H., C.E.F., H.S. and J.P.M.T.; supervision, C.T.R.H., C.E.F. and J.P.M.T.; project administration, J.P.M.T. All authors have read and agreed to the published version of the manuscript.
Funding
This research received no external funding.
Institutional Review Board Statement
Ethical review and approval were not requested for this article, as it is a narrative review and the clinical photographs presented were obtained during routine dental care and were not collected as part of a research study.
Informed Consent Statement
Written informed consent was obtained from the patient for publication of this paper and any accompanying images.
Data Availability Statement
No new data were created or analyzed in this study.
Conflicts of Interest
The authors declare no conflicts of interest.
References
- Dietschi, D.; Duc, O.; Krejci, I.; Sadan, A. Biomechanical Considerations for the Restoration of Endodontically Treated Teeth: A Systematic Review of the Literature-Part 1. Composition and Micro- and Macrostructure Alterations. Quintessence Int. 2007, 38, 733–743. [Google Scholar] [PubMed]
- Dietschi, D.; Duc, O.; Krejci, I.; Sadan, A. Biomechanical Considerations for the Restoration of Endodontically Treated Teeth: A Systematic Review of the Literature, Part II (Evaluation of Fatigue Behavior, Interfaces, and in Vivo Studies). Quintessence Int. 2008, 39, 117–129. [Google Scholar] [PubMed]
- Santos Pantaleón, D.; Morrow, B.R.; Cagna, D.R.; Pameijer, C.H.; Garcia-Godoy, F. Influence of Remaining Coronal Tooth Structure on Fracture Resistance and Failure Mode of Restored En-Dodontically Treated Maxillary Incisors. J. Prosthet. Dent. 2018, 119, 390–396. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Naumann, M.; Schmitter, M.; Frankenberger, R.; Krastl, G. Ferrule Comes First. Post Is Sec-Ond!” Fake News and Alternative Facts? A Systematic Review. J. Endod. 2018, 44, 212–219. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Bergoli, C.D.; Brondani, L.P.; Wandscher, V.F.; Pereira, G.; Cenci, M.S.; Pereira-Cenci, T.; Valandro, L.F. A Multicenter Randomized Double-Blind Controlled Clinical Trial of Fiber Post Cementation Strategies. Oper. Dent. 2018, 43, 128–135. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Goracci, C.; Ferrari, M. Current Perspectives on Post Systems: A Literature Review: Post Systems. Aust. Dent. J. 2011, 56, 77–83. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Cordaro, M.; Staderini, E.; Torsello, F.; Grande, N.M.; Turchi, M.; Cordaro, M. Orthodontic Extrusion vs. Surgical Extrusion to Rehabilitate Severely Damaged Teeth: A Literature Review. Int. J. Environ. Res. Public Health 2021, 18, 9530. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Cagidiaco, M.C.; Goracci, C.; Garcia-Godoy, F.; Ferrari, M. Clinical Studies of Fiber Posts: A Literature Review. Int. J. Prosthodont. 2008, 21, 328–336. [Google Scholar] [PubMed]
- Rasimick, B.J.; Wan, J.; Musikant, B.L.; Deutsch, A.S. A Review of Failure Modes in Teeth Restored with Adhesively Luted Endodontic Dowels: Failure Modes of Adhesively Luted Dowels. J. Prosthodont. 2010, 19, 639–646. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Naumann, M.; Koelpin, M.; Beuer, F.; Meyer-Lueckel, H. 10-Year Survival Evaluation for Glass-Fiber-Supported Postendodontic Restoration: A Prospective Observational Clinical Study. J. Endod. 2012, 38, 432–435. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Ferrari, M.; Mannocci, F.; Vichi, A.; Cagidiaco, M.C.; Mjör, I.A. Bonding to Root Canal: Structural Characteristics of the Substrate. Am. J. Dent. 2000, 13, 255–260. [Google Scholar] [PubMed]
- Zicari, F.; Couthino, E.; De Munck, J.; Poitevin, A.; Scotti, R.; Naert, I.; Van Meerbeek, B. Bonding Effectiveness and Sealing Ability of Fiber-Post Bonding. Dent. Mater. 2008, 24, 967–977. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Souza, A.C.d.O.; Gonçalves, F.d.C.P.; Anami, L.C.; de Melo, R.M.; Bottino, M.A.; Valandro, L.F. Influence of Insertion Techniques for Resin Cement and Mechanical Cycling on the Bond Strength between Fiber Posts and Root Dentin. J. Adhes. Dent. 2015, 17, 175–180. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Ferrari, M.; Cagidiaco, M.C.; Goracci, C.; Vichi, A.; Mason, P.N.; Radovic, I.; Tay, F. Long-Term Retrospective Study of the Clinical Performance of Fiber Posts. Am. J. Dent. 2007, 20, 287–291. [Google Scholar] [PubMed]
- Juloski, J.; Fadda, G.M.; Monticelli, F.; Fajó-Pascual, M.; Goracci, C.; Ferrari, M. Four-Year Survival of Endodontically Treated Premolars Restored with Fiber Posts. J. Dent. Res. 2014, 93, 52S–58S. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Gomes, G.M.; Gomes, O.M.M.; Reis, A.; Gomes, J.C.; Loguercio, A.D.; Calixto, A.L. Effect of Operator Experience on the Outcome of Fiber Post Cementation with Different Resin Cements. Oper. Dent. 2013, 38, 555–564. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- van Noort, R. Introduction to Dental Materials, 4th ed.; Mosby: London, UK, 2013. [Google Scholar]
- Sunico-Segarra, M.; Segarra, A. A Practical Clinical Guide to Resin Cements; Springer: Berlin, Germany, 2016. [Google Scholar]
- Yadav, R.; Sonwal, S.; Bukhari, K.M.A.; Khan, R.; Brambilla, E.; Huh, Y.S.; Ionescu, A.C. Mechanical Integrity of Dental Hard Tissues during Demineralization-Remineralization: A Review of Bioceramic and Remineralizing Materials. J. Korean Ceram. Soc. 2026, 1–19. [Google Scholar] [CrossRef] [Scilit]
- Nakabayashi, N.; Nakamura, M.; Yasuda, N. Hybrid Layer as a Dentin-Bonding Mechanism. J. Esthet. Dent. 1991, 3, 133–138. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Van Meerbeek, B.; Yoshihara, K.; Yoshida, Y.; Mine, A.; De Munck, J.; Van Landuyt, K.L. State of the Art of Self-Etch Adhesives. Dent. Mater. 2011, 27, 17–28. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Della Bona, A. Bonding to Ceramics: Scientific Evidences for Clinical Dentistry; Artes Medicas: Quito, Ecuador, 2009. [Google Scholar]
- Pegoraro, L.F.; Valle, A.L.; De Araujo C Dos, R.P.; Bonfante, G.; Conti, P. Fixed Prosthesis: Bases for Planning in Oral Rehabilitation; Artes Médicas Editora: São Paulo, Brazil, 2013. [Google Scholar]
- Shaikh, S.Y.; Shaikh, S.S. Direct Linear Measurement of Root Dentin Thickness and Dentin Volume Changes with Post Space Preparation: A Cone-Beam Computed Tomography Study. Contemp. Clin. Dent. 2018, 9, 77–82. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Aboushelib, M.N. Clinical Performance of Self-Etching Adhesives with Saliva Contamination. J. Adhes. Dent. 2011, 13, 489–493. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Kawaguchi-Uemura, A.; Mine, A.; Matsumoto, M.; Tajiri, Y.; Higashi, M.; Kabetani, T.; Hagino, R.; Imai, D.; Minamino, T.; Miura, J.; et al. Adhesion Procedure for CAD/CAM Resin Crown Bonding: Reduction of Bond Strengths Due to Artificial Saliva Contamination. J. Prosthodont. Res. 2018, 62, 177–183. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- European Society of Endodontology. Quality Guidelines for Endodontic Treatment: Consensus Report of the European Society of Endodontology. Int. Endod. J. 2006, 39, 921–930. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Bouillaguet, S.; Troesch, S.; Wataha, J.C.; Krejci, I.; Meyer, J.M.; Pashley, D.H. Microtensile Bond Strength between Adhesive Cements and Root Canal Dentin. Dent. Mater. 2003, 19, 199–205. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Goracci, C.; Fabianelli, A.; Sadek, F.T.; Papacchini, F.; Tay, F.R.; Ferrari, M. The Contribution of Friction to the Dislocation Resistance of Bonded Fiber Posts. J. Endod. 2005, 31, 608–612. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- do Nascimento, W.F.; de Andrade, G.S.; Tribst, J.P.M.; Uemura, E.S.; Saavedra, G.S.F.A. One-Piece, CAD/CAM, Fiber-Reinforced Composite Post and Core: A Case Report. Gen. Dent. 2021, 69, 64–68. [Google Scholar] [PubMed]
- de Andrade, G.-S.; Tribst, J.-P.-M.; Dal Piva, A.-M.O.; Bottino, M.-A.; Borges, A.-L.-S.; Valandro, L.-F.; Özcan, M. A Study on Stress Distribution to Cement Layer and Root Dentin for Post and Cores Made of CAD/CAM Materials with Different Elasticity Modulus in the Absence of Ferrule. J. Clin. Exp. Dent. 2019, 11, e1–e8. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Campos, G.B.; Pellizzer, E.P.; De Carvalho, R.F.; De Lima, C.O.; Oliveira, H.F.F.; De Oliveira Limirio, J.P.J.; Lemos, C.A. Are CAD-CAM Milled Glass Fiber Posts Better than Prefabricated or Custom Glass Fiber Posts for Endodontically Treated Teeth? A Systematic Review with Meta-Analysis. J. Prosthet. Dent. 2025, 134, 1542–1554. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Bottino, M.A.; Faria, R.; Valandro, L.F. Perception: Aesthetics in Metal-Free Prostheses in Natural Teeth and Implants; Artes Médicas: São Paulo, Brazil, 2009. [Google Scholar]
- Perdigão, J.; Gomes, G.; Augusto, V. The Effect of Dowel Space on the Bond Strengths of Fiber Posts. J. Prosthodont. 2007, 16, 154–164. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Furuse, A.Y.; Cunha, L.F.; Baratto, S.P.; Leonardi, D.P.; Haragushiku, G.A.; Gonzaga, C.C. Bond Strength of Fiber-Reinforced Posts to Deproteinized Root Canal Dentin. J. Contemp. Dent. Pract. 2014, 15, 581–586. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Khoroushi, M.; Sheikhi, M.; Khalilian-Gourtani, A.; Soleimani, B. Effect of Root Canal Rinsing Protocol on Dentin Bond Strength of Two Resin Cements Using Three Different Method of Test. J. Clin. Exp. Dent. 2016, 8, e246–e254. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Gonçalves, A.P.R.; Ogliari, A.d.O.; Jardim, P.d.S.; de Moraes, R.R. Chemical Cleaning Agents and Bonding to Glass-Fiber Posts. Braz. Oral Res. 2013, 27, 70–72. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Protogerou, E.; Arvaniti, I.; Vlachos, I.; Khabbaz, M.G. Effectiveness of a Canal Brush on Removing Smear Layer: A Scanning Electron Microscopic Study. Braz. Dent. J. 2013, 24, 580–584. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Oliveira, L.V.; Maia, T.S.; Zancopé, K.; Menezes, M.D.S.; Soares, C.J.; Moura, C. Can Intra-Radicular Cleaning Protocols Increase the Retention of Glass-Fiber Posts? A Systematic Review. Braz. Oral Res. 2018, 32, e16. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Jurema, A.L.B.; Correia, A.M.O.; Spinola, M.S.; Bresciani, E.; Caneppele, T.M.F. Influence of Different Intraradicular Chemical Pretreatments on the Bond Strength of Adhesive Interface between Dentine and Fiber Post Cements: A Systematic Review and Network Meta-Analysis. Eur. J. Oral Sci. 2022, 130, e12881. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Demiryürek, E.O.; Külünk, S.; Yüksel, G.; Saraç, D.; Bulucu, B. Effects of Three Canal Sealers on Bond Strength of a Fiber Post. J. Endod. 2010, 36, 497–501. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Bitter, K.; Polster, L.; Askar, H.; von Stein-Lausnitz, M.; Sterzenbach, G. Effect of Final Irrigation Protocol and Etching Mode on Bond Strength of a Multimode Adhesive in the Root Canal. J. Adhes. Dent. 2017, 19, 245–252. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Ahmadi, E.; Sheikh-Al-Eslamian, S.M.; Valizadeh, S.; Kharazifard, M.J.; Aghajani, F. Effect of Root Dentin Pretreatment with Different Concentrations of Chitosan on the Push-out Bond Strength of Fiber Post Using a Self-Adhesive Resin Cement. BMC Oral Health 2025, 25, 294. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Silva, R.C.; Barbosa, M.d.A.; Michels, B.; Carelli, J.; Weber, K.R.; Gonzaga, C.C.; Tomazinho, F.S.F. Effect of the Endodontic Sealer on the Bond Strength of Glass Fiber Posts. Gen. Dent. 2025, 73, 51–54. [Google Scholar] [PubMed]
- Porto, Á.R.N.P.; Moreira, R.F.; Belladonna, F.G.; Vieira, V.T.L.; da Silva, E.J.N.L. Does the Use of Different Root Canal Sealers and Adhesive Resin Cements Impact the Bond Strength of Glass Fiber Posts? Restor. Dent. Endod. 2025, 50, e29. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Antunes, T.B.M.; Bronzato, J.D.; Pecorari, V.G.A.; Pereira, J.S.; Tartari, T.; de Jesus Soares, A.; Gomes, B.P.F.A.; Marciano, M.A. Effect of Endodontic Sealers on the Bond Strength of Glass Fibre Posts: A Systematic Review. Aust. Endod. J. 2026, 52, 554–570. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Moraes, A.P.; Sarkis-Onofre, R.; Moraes, R.R.; Cenci, M.S.; Soares, C.J.; Pereira-Cenci, T. Can Silanization Increase the Retention of Glass-Fiber Posts? A Systematic Review and Meta-Analysis of In Vitro Studies. Oper. Dent. 2015, 40, 567–580. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Sipahi, C.; Piskin, B.; Akin, G.E.; Bektas, O.O.; Akin, H. Adhesion between Glass Fiber Posts and Resin Cement: Evaluation of Bond Strength after Various Pre-Treatments. Acta Odontol. Scand. 2014, 72, 509–515. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- de Sousa Menezes, M.; Queiroz, E.C.; Soares, P.V.; Faria-e-Silva, A.L.; Soares, C.J.; Martins, L.R.M. Fiber Post Etching with Hydrogen Peroxide: Effect of Concentration and Application Time. J. Endod. 2011, 37, 398–402. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Valdivia, A.; Novais, V.R.; Menezes M De, S.; Roscoe, M.G.; Estrela, C.; Soares, C.J. Effect of Surface Treatment of Glass-Fiber Posts on Bond Strength to Root Dentin. Braz. Dent. J. 2014, 25, 314–320. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Monticelli, F.; Osorio, R.; Sadek, F.T.; Radovic, I.; Toledano, M.; Ferrari, M. Surface Treatments for Improving Bond Strength to Prefabricated Fiber Posts: A Literature Review. Oper. Dent. 2008, 33, 346–355. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Dos Santos, L.R.; Lima, D.M.; Carvalho, E.M.; Rodrigues, V.P.; Alves, C.M.C. Effect of Glass Fiber Post Surface Treatment on Bond Strength of a Self-Adhesive Resin Cement: An “in Vitro” Study. Int. J. Dent. 2021, 2021, 8856657. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Mishra, L.; Khan, S.; Mattar, A. Effects of Surface Treatments of Glass Fi-Ber-Reinforced Post on Bond Strength to Root Dentine: A Systematic Review. Materials 2020, 13, 1967. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Elalfy, N.S.M.; Elbasty, R.S. Effect of Er: YAG Laser and Different Surface Treatment Methods on the Push-out Bond Strength of Glass Fiber Post to Self Adhesive Resin Cement. Lasers Med. Sci. 2025, 40, 80. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Arıcan, B.; Evrendilek, F.; Özalp Koca, A.T.; Senemli, Y.; Özyürek, T. Er:YAG Laser Irradiation versus Conventional Surface Treatments: A Pull-out Bond Strength Study on Glass Fiber Posts. Lasers Med. Sci. 2026, 41, 189. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Tsolomitis, P.; Diamantopoulou, S.; Papazoglou, E. Contemporary Concepts of Adhesive Cementation of Glass-Fiber Posts: A Narrative Review. J. Clin. Med. 2024, 13, 3479. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Boff, L.L.; Grossi, M.L.; Prates, L.H.M.; Burnett, L.H., Jr.; Shinkai, R.S.A. Effect of the Activation Mode of Post Adhesive Cementation on Push-out Bond Strength to Root Canal Dentin. Quintessence Int. 2007, 38, 387–394. [Google Scholar] [PubMed]
- Abou-Id, L.R.; Morgan, F.; Silva, G.; Poletto Lt De, A.; Lanza, L.D.; Albuquerque R De, C. Ultrastructural Evaluation of the Hybrid Layer after Cementation of Fiber Posts Using Adhe-Sive Systems with Different Curing Modes. Braz. Dent. J. 2012, 23, 116–121. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Breschi, L.; Mazzoni, A.; De Stefano Dorigo, E.; Ferrari, M. Adhesion to Intraradicular Dentin: A Review. J. Adhes. Sci. Technol. 2009, 23, 1053–1083. [Google Scholar] [CrossRef] [Scilit]
- Sarkis-Onofre, R.; Skupien, J.A.; Cenci, M.S.; Moraes, R.R.; Pereira-Cenci, T. The Role of Resin Cement on Bond Strength of Glass-Fiber Posts Luted into Root Canals: A Systematic Review and Meta-Analysis of in Vitro Studies. Oper. Dent. 2014, 39, E31–E44. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Spencer, P.; Wang, Y.; Walker, M.P.; Wieliczka, D.M.; Swafford, J.R. Interfacial Chemistry of the Dentin/Adhesive Bond. J. Dent. Res. 2000, 79, 1458–1463. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- De Munck, J.; Vargas, M.; Van Landuyt, K.; Hikita, K.; Lambrechts, P.; Van Meerbeek, B. Bonding of an Auto-Adhesive Luting Material to Enamel and Dentin. Dent. Mater. 2004, 20, 963–971. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Monticelli, F.; Osorio, R.; Mazzitelli, C.; Ferrari, M.; Toledano, M. Limited Decalcification/Diffusion of Self-Adhesive Cements into Dentin. J. Dent. Res. 2008, 87, 974–979. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Özcan, M.; Mese, A. Adhesion of Conventional and Simplified Resin-Based Luting Cements to Superficial and Deep Dentin. Clin. Oral Investig. 2012, 16, 1081–1088. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Amaral, M.; Santini, M.F.; Wandscher, V.; Amaral, R.; Valandro, L.F. An in Vitro Comparison of Different Cementation Strategies on the Pull-out Strength of a Glass Fiber Post. Oper. Dent. 2009, 34, 443–451. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Skupien, J.A.; Sarkis-Onofre, R.; Cenci, M.S.; de Moraes, R.R.; Pereira-Cenci, T. A Systematic Review of Factors Associated with the Retention of Glass Fiber Posts. Braz. Oral Res. 2015, 29, 1–8. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Kanca, I.J.; Sandrik, J. Bonding to Dentin. Clues to the Mechanism of Adhesion. Am. J. Dent. 1998, 11, 154–159. [Google Scholar] [PubMed]
- Souza, R.O.A.; Lombardo, G.H.L.; Michida, S.M.A.; Galhano, G.; Bottino, M.A.; Valandro, L.F. Influence of Brush Type as a Carrier of Adhesive Solutions and Paper Points as an Adhesive-Excess Remover on the Resin Bond to Root Dentin. J. Adhes. Dent. 2007, 9, 521–526. [Google Scholar] [CrossRef] [Scilit]
- Aziz, T.M.; Anwar, M.N.; El-Askary, F.S. Push-out Bond Strength of Fiber Posts to Root Canal Dentin Using a One-Step Self-Etching Adhesive: The Effect of Solvent Removal and Light-Curing Methods. J. Adhes. Dent. 2014, 16, 79–86. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Hashimoto, M.; Tay, F.R.; Ito, S.; Sano, H.; Kaga, M.; Pashley, D.H. Permeability of Adhesive Resin Films. J. Biomed. Mater. Res. B Appl. Biomater. 2005, 74, 699–705. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Thitthaweerat, S.; Nakajima, M.; Foxton, R.M.; Tagami, J. Effect of Solvent Evaporation Strategies on Regional Bond Strength of One-Step Self-Etch Adhesives to Root Canal Dentine. Int. Endod. J. 2013, 46, 1023–1031. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Tay, F.R.; Pashley, D.H.; Suh, B.I.; Carvalho, R.M.; Itthagarun, A. Single-Step Adhesives Are permeable Membranes. J. Dent. 2002, 30, 371–382. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Swift, E.J., Jr.; Perdigão, J.; Combe, E.C.; Simpson, C.H., 3rd; Nunes, M.F. Effects of Restorative and Adhesive Curing Methods on Dentin Bond Strengths. Am. J. Dent. 2001, 14, 137–140. [Google Scholar] [PubMed]
- Cheong, C.; King, N.M.; Pashley, D.H.; Ferrari, M.; Toledano, M.; Tay, F.R. Incompatibility of Self-Etch Adhesives with Chemical/Dual-Cured Composites: Two-Step vs One-Step Systems. Oper. Dent. 2003, 28, 747–755. [Google Scholar] [PubMed]
- Tay, F.R.; Suh, B.I.; Pashley, D.H.; Prati, C.; Chuang, S.-F.; Li, F. Factors Contributing to the Incompatibility Between Simplified-Step Adhesives and Self-Cured or Dual-Cured Composites. Part II. Single-Bottle, Total-Etch Adhesive. J. Adhes. Dent. 2003, 5, 91–105. [Google Scholar] [PubMed]
- Heráclio, M.E.; Nascimento, A.J.; Silva, C.G.; Assis, C.P.; Braz, R.; Correia, T. Evaluation of Bond Strengths of Conventional and Self-Adhesive Cements in the Cementation of Glass-Fiber Posts: A Systematic Review and Meta-Analysis. Oper. Dent. 2025, 50, 280–292. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Baran, G.; Boberick, K.; McCool, J. Fatigue of Restorative Materials. Crit. Rev. Oral Biol. Med. 2001, 12, 350–360. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- De Andrade, G.S.; Tribst, J.P.M.; Orozco, E.I.F.; Augusto, M.G.; Bottino, M.A.; Borges, A.L.S.; Anami, L.C.; Saavedra, G.S.F.A. Influence of Different Post-Endodontic Restoration on the Fatigue Survival and Biomechanical Behavior of Central Incisors. Am. J. Dent. 2020, 33, 227–234. [Google Scholar] [PubMed]
- da Silva, N.R.; Aguiar, G.C.R.; Rodrigues, M.P.; Bicalho, A.A.; Soares, P.B.F.; Veríssimo, C.; Soares, C.J. Effect of Resin Cement Porosity on Retention of Glass-Fiber Posts to Root Dentin: An Experimental and Finite Element Analysis. Braz. Dent. J. 2015, 26, 630–636. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Da Silva, N.R.; Rodrigues M De, P.; Bicalho, A.A.; Soares, P.; Price, R.B.; Soares, C.J. Effect of Resin Cement Mixing and Insertion Method into the Root Canal on Cement Porosity and Glass-Fiber Post Bond Strength. J. Adhes. Dent. 2019, 21, 37–46. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Uzun, İ.H.; Malkoç, M.A.; Keleş, A.; Öğreten, A.T. 3D Micro-CT Analysis of Void Formations and Push-out Bonding Strength of Resin Cements Used for Fiber Post Cementation. J. Adv. Prosthodont. 2016, 8, 101–109. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Grandini, S.; Goracci, C.; Monticelli, F.; Borracchini, A.; Ferrari, M. SEM Evaluation of the Cement Layer Thickness after Luting Two Different Posts. J. Adhes. Dent. 2005, 7, 235–240. [Google Scholar] [PubMed]
- Watzke, R.; Frankenberger, R.; Naumann, M. Probability of Interface Imperfections within SEM Cross-Sections of Adhesively Luted GFP. Dent. Mater. 2009, 25, 1256–1263. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- de Assis, H.C.; Cronenbold, T.J.; Prado, H.S.; Eyüboğlu, T.F.; Özcan, M.; Sousa-Neto, M.D.; Lopes-Olhê, F.C.; Mazzi-Chaves, J.F. Role of Post Design and Cement Type in Fiber Post Adaptation and Retention. BMC Oral Health 2026, 26, 320. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Akgungor, G.; Akkayan, B. Influence of Dentin Bonding Agents and Polymerization Modes on the Bond Strength between Translucent Fiber Posts and Three Dentin Regions within a Post Space. J. Prosthet. Dent. 2006, 95, 368–378. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Atalay, C.; Yazici, A.R.; Horuztepe, A.; Nagas, E.; Ertan, A.; Ozgunaltay, G. Fracture Resistance of Endodontically Treated Teeth Restored with Bulk Fill, Bulk Fill Flowable, Fiber-Reinforced, and Conventional Resin Composite. Oper. Dent. 2016, 41, E131–E140. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Dietschi, D.; Spreafico, R. Adhesive Metal-Free Restorations: Current Concepts for the Esthetic Treatment of Posterior Teeth; Quintessence Pub. Co.: Batavia, IL, USA, 1997. [Google Scholar]
- Panitiwat, P.; Salimee, P. Effect of Different Composite Core Materials on Fracture Resistance of Endodontically Treated Teeth Restored with FRC Posts. J. Appl. Oral Sci. 2017, 25, 203–210. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Chutinan, S.; Platt, J.A.; Cochran, M.A.; Moore, B.K. Volumetric Dimensional Change of Six Direct Core Materials. Dent. Mater. 2004, 20, 345–351. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Sterzenbach, G.; Karajouli, G.; Tunjan, R.; Spintig, T.; Bitter, K.; Naumann, M. Damage of Lithi-Um-Disilicate All-Ceramic Restorations by an Experimental Self-Adhesive Resin Cement Used as Core Build-Ups. Clin. Oral Investig. 2015, 19, 281–288. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Bitter, K.; Schubert, A.; Neumann, K.; Blunck, U.; Sterzenbach, G.; Rüttermann, S. Are Self-Adhesive Resin Cements Suitable as Core Build-up Materials? Analyses of Maximum Load Capability, Margin Integrity, and Physical Properties. Clin. Oral Investig. 2016, 20, 1337–1345. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Sindel, J.; Frankenberger, R.; Krämer, N.; Petschelt, A. Crack Formation of All-Ceramic Crowns Dependent on Different Core Build-up and Luting Materials. J. Dent. 1999, 27, 175–181. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Zankuli, M.A.; Devlin, H.; Silikas, N. Water Sorption and Solubility of Core Build-up Materials. Dent. Mater. 2014, 30, e324–e329. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Monticelli, F.; Goracci, C.; Grandini, S.; García-Godoy, F.; Ferrari, M. Scanning Electron Micro-Scopic Evaluation of Fiber Post-Resin Core Units Built up with Different Resin Composites. Am. J. Dent. 2005, 18, 61–65. [Google Scholar] [PubMed]
- De Jager, N.; de Kler, M.; van der Zel, J.M. The Influence of Different Core Material on the FEA-Determined Stress Distribution in Dental Crowns. Dent. Mater. 2006, 22, 234–242. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Reis, J.M.D.S.N.; Oliveira, C.R.d.M.; Reis, E.G.J.; Mascaro, B.A.; Abi-Rached, F.d.O. One-Step Fiber Post Cementation and Core Build-up in Endodontically Treated Tooth: A Clinical Case Report. J. Esthet. Restor. Dent. 2020, 32, 5–11. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Haller, B. Which Self-Etch Bonding Systems Are Suitable for Which Clinical Indications? Quintessence Int. 2013, 44, 645–661. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Borges, M.G.; Faria-e-Silva, A.L.; Santos-Filho, P.C.F.; Silva, F.P.; Martins, L.R.M.; Menezes, M.d.S. Does the Moment of Fiber Post Cutting Influence on the Retention to Root Dentin? Braz. Dent. J. 2015, 26, 141–145. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Garoushi, S.; Säilynoja, E.; Vallittu, P.K.; Lassila, L. Physical Properties and Depth of Cure of a New Short Fiber Reinforced Composite. Dent. Mater. 2013, 29, 835–841, Correction in Dent. Mater. 2016, 32, 1196. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Magne, P.; Carvalho, M.A.; Milani, T. Shrinkage-Induced Cuspal Deformation and Strength of Three Different Short Fiber-Reinforced Composite Resins. J. Esthet. Restor. Dent. 2023, 35, 56–63. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Magne, P.; Milani, T. Short-Fiber Reinforced MOD Restorations of Molars with Severely Undermined Cusps. J. Adhes. Dent. 2023, 25, 99–106. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Cho, K.; Wang, G.; Raju; Fang, J.; Rajan, G.; Stenzel, M.H.; Farrar, P.; Prusty, B.G. Selective Atomic-Level Etching on Short S-Glass Fibres to Control Interfacial Properties for Restorative Dental Composites. Sci. Rep. 2019, 9, 3851. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Kamourieh, N.; Faigenblum, M.; Blizard, R.; Leung, A.; Fine, P. Fracture Toughness of Short Fibre-Reinforced Composites—In Vitro Study. Materials 2024, 17, 5368. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Escobar, L.B.; Pereira da Silva, L.; Manarte-Monteiro, P. Fracture Resistance of Fiber-Reinforced Composite Restorations: A Systematic Review and Meta-Analysis. Polymers 2023, 15, 3802. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Jakab, A.; Palkovics, D.; T Szabó, V.; Szabó, B.; Vincze-Bandi, E.; Braunitzer, G.; Lassila, L.; Vallittu, P.; Garoushi, S.; Fráter, M. Mechanical Performance of Extensive Restorations Made with Short Fiber-Reinforced Composites without Coverage: A Systematic Review of in Vitro Studies. Polymers 2024, 16, 590. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Gürel, M.A.; Helvacioğlu Kivanç, B.; Ekıcı, A.; Alaçam, T. Fracture Resistance of Premolars Restored Either with Short Fiber or Polyethylene Woven Fiber-Reinforced Composite: Fracture Resistance of Premolars. J. Esthet. Restor. Dent. 2016, 28, 412–418. [Google Scholar] [CrossRef] [Scilit] [PubMed]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.






