Physics-Informed Composition-to-Tank Modelling of Metal Hydride Hydrogen Storage

,
and
1
Computer Technologies Department, Computer Science and AI Faculty, Yessenov Caspian University of Technology and Engineering, Aktau 130000, Kazakhstan
2
Management and Entrepreneurship Department, Ravensbourne University, London SE10 0EW, UK
3
Computer Engineering Department, Business Administration Faculty, Azerbaijan State Oil and Industry University, Baku AZ1010, Azerbaijan
*
Author to whom correspondence should be addressed.

Abstract

Composition-based machine-learning models can estimate metal hydride thermodynamics, but their errors are reported at the material level, whereas storage systems are judged at the tank level, and this study connects the two. Gradient-boosting models trained on 420 hydrides with a van ’t Hoff-consistent parameterization predict the room-temperature plateau, ln Peq, with cross-validated mean absolute errors of 0.90 for AB5 and 1.75 for AB2 alloys. A reduced-order heat- and mass-transfer model of an open 7.8 kg AB2 tank was calibrated on the pressure, temperature and flow time series of one test and reproduced two further tests within 3.5–5.5 °C and 0.4–1.0 bar. The tank data place the alloy’s plateau at ln Peq = 2.59–2.68, 2.0 units above the prediction, while the predicted enthalpy is within about 2 kJ mol−1. With predicted thermodynamics, the simulated tank absorbs 60 g in 1.1 h instead of 8.8 h, peaks at 106 °C instead of 58 °C and delivers 31% less hydrogen; delivered capacity tolerates plateau errors of about −1.5/+0.25, charging behaviour only ±0.15. Composition models nevertheless rank substitution series correctly, as shown for La1−xCexNi5 and LaNi5−xAlx, and combined with one measured isotherm they offer a fast route from alloy composition to tank design.

1. Introduction

Storing hydrogen in reversible intermetallic hydrides remains attractive wherever volumetric density, low operating pressure and intrinsic safety matter more than gravimetric capacity, for example in stationary buffers for renewable electricity, backup power and small fuel-cell systems [1,2,3,4]. In these applications the alloy is not selected for its capacity alone. Its equilibrium (plateau) pressure must sit inside a window fixed by the rest of the system: high enough at the lowest discharge temperature to feed a fuel cell, and low enough at the highest charging temperature to be filled by an electrolyser or compressor [5,6,7]. Whether a given tank actually delivers its nominal capacity then depends on how fast the reaction heat can be removed or supplied, which is why heat management dominates engineering studies of metal hydride (MH) vessels [8,9,10,11,12].
For AB5 and AB2 intermetallics, the plateau pressure is tuned by partial substitution of the A-site element (e.g., La in LaNi5) or of the B-site element (e.g., Ni) with other metals. In LaNi5, replacing La with Ce raises the plateau and replacing Ni with Al or Mn lowers it, at some cost in capacity and hysteresis [13,14,15]. Systems built around this logic include La1−xCexNi5 accumulators coupled to photovoltaic electrolysis and fuel cells [16], and LaNi5−xAlx units that absorb near-atmospheric hydrogen from solid-oxide electrolysers and release it at a few bar on heating [17,18]. In each case, the composition was chosen by measuring a short series of candidate alloys. The question this paper asks is whether part of that experimental screening can be done in silico, and with what confidence.
Data-driven models of hydride thermodynamics have made this question concrete. The HydPARK compilation and its machine-learning-ready derivative ML-HydPARK provide formation enthalpies, entropies and plateau pressures for several hundred intermetallics [19]. Models trained on composition-derived descriptors predict these quantities with useful accuracy [20,21,22], have been used to screen high-entropy hydrides [23], and continue to improve as databases grow [24,25]. These studies, however, report accuracy at the material level: a mean absolute error in ΔH or in ln Peq. A tank designer needs a different number: how wrong the predicted delivered capacity, charging time or bed temperature will be when the predicted thermodynamics are used in place of a measured isotherm. An error of one unit in ln Peq is a factor of 2.7 in pressure. Whether that is negligible or disqualifying depends on the vessel, its heat exchange and its pressure limits, not on the regression model.
On the device side, heat and mass transfer in MH beds is well-described by continuum models that combine an energy balance, a gas balance, an equilibrium pressure law and a rate expression [8,11,26]. Machine learning has entered this side as well, through surrogate and physics-informed formulations [27,28,29] and data-driven identification of kinetic models [30]. The two lines of work are rarely connected. Tank models take thermodynamic inputs from measured pressure–composition–temperature (PCT) data, and composition models end with a predicted plateau pressure, which is not carried through to device performance. In addition, open tank-scale data sets are scarce, so neither side is usually tested against an independent device.
This work connects the two levels and uses that connection to ask a specific question: what accuracy in composition-predicted thermodynamics is sufficient for tank-level decisions? We (i) train composition-based models for ΔH and ln Peq on ML-HydPARK, using a van ’t Hoff-consistent parameterization and class-resolved error estimates; (ii) build a reduced-order, physics-based model of a cylindrical MH tank and calibrate it against the pressure, temperature and flow time series of a recently published open data set for a 7.8 kg AB2 tank [31], using one charge rate for calibration and two for validation; (iii) use the composition-model prediction as a prior estimate of the plateau pressure and formation enthalpy of the tank alloy, and compare it with the values obtained by calibrating the tank model to the measured pressure, temperature and flow time series; and (iv) propagate the material-level error to tank performance through scenario analysis, variance-based sensitivity indices and an explicit tolerance window, before applying the calibrated tank to a virtual screen of the La–Ce–Ni and La–Ni–Al AB5 series. The emphasis is on what the combination can and cannot establish from routinely logged tank data, rather than on a new regression model.

2. Materials and Methods

2.1. Thermodynamic Data

The material-level data were taken from ML-HydPARK v0.0.5 [19], a cleaned, machine-learning-ready version of the historical HydPARK database. It contains 420 entries with composition, formation enthalpy ΔH and entropy ΔS (reported as positive magnitudes per mol H2), gravimetric capacity and the plateau pressure at 298 K expressed as ln(Peq/P0), where P0 = 1 atm is the standard pressure. Entries were grouped into the classes used in the source (AB5, AB2, AB, A2B, Mg-based, multicomponent intermetallics (MIC) and solid solutions (SS)); the 23 entries added in later database versions without a class label were assigned by stoichiometry, giving 131 AB2, 112 AB5, 52 MIC, 49 SS, 34 AB, 32 Mg-based and 10 A2B entries. Each entry was checked for internal consistency through the van ’t Hoff relation; the largest deviation between reported and recomputed ln Peq was 0.07, so no entry was removed. Four compositions occur twice after normalization with independent measurements and were retained.

2.2. Composition Descriptors and Equilibrium Models

Each composition was parsed with pymatgen [32] and described by 146 composition-based features from matminer [33]: the 132 Magpie elemental-property statistics [34], six stoichiometric norms and eight valence-orbital fractions. Gradient-boosting regression (GBR) [35] was used with the hyperparameters adopted by Witman et al. for hydride thermodynamics [22] (1500 trees, learning rate 0.005, depth 4, subsampling 0.75); random forests (500 trees) served as a baseline. Both were implemented in scikit-learn [36].
Further two parameterizations of the equilibrium were compared. In the independent scheme, ΔH and ΔS are regressed separately. In the van ’t Hoff-consistent scheme, ΔH and ln Peq at T0 = 298.15 K are regressed, and the entropy follows from
ΔS = R ln(Peq,0/P0) + ΔH/T0,
where R is the universal gas constant and Peq,0 is the plateau pressure at T0, so that the predicted isotherm is anchored where the data are densest and only its temperature slope depends on ΔH. Because ΔH and ΔS are strongly correlated (enthalpy–entropy compensation), small independent errors in both can produce large errors in Peq; the second scheme avoids this. Predictions were scored by the mean absolute error (MAE) in ln Peq at 298 and 348 K, i.e., across the temperature range relevant for the tank studied below.
Accuracy was estimated by 5-fold cross-validation repeated three times with different splits, and, to probe extrapolation, by leave-class-out tests in which all AB2 or all AB5 entries were withheld from training. Out-of-fold residual pairs (eH, elnP) were stored per class. Their empirical distribution, rather than the spread of a model ensemble, was used as the error model of a prediction, since ensembles trained on the same data underestimate the error for compositions unlike the training set.

2.3. Tank Data Set

The device-level data come from an open data set describing a prototype AB2 tank designed to supply a 300 W proton-exchange-membrane fuel cell [31]. The vessel is a 316 L stainless-steel cylinder (3.5-inch schedule 80, wall 8.08 mm, 321 mm long, 2.53 L internal volume) holding 7.8 kg of Ti0.815Zr0.185Cr0.77Fe0.07Mn0.88 with a nominal capacity of about 1.76 wt%. Flow, pressure and five shell thermocouples (TC1–TC5) were logged at 1 s intervals during three tests. In each test the activated bed was evacuated and charged with the mass-flow controller set to 5, 10 or 15 standard litres per minute (SLPM); the set flow was held only until the pressure reached the supply limit of about 24–25 bar (gauge), after 1.2, 0.44 and 0.29 h respectively, and charging then continued at the supply pressure for 18–28 h. The tank was subsequently discharged at a set flow of 5 SLPM until the pressure reached about 0.3–0.5 bar (gauge), after which the flow decayed to zero over several hours.
We consider that two features of the logs matter for modelling. First, the pressure readings are interpreted as gauge values (they read zero under vacuum and approach zero at the end of discharge to atmosphere), so 1.013 bar was added throughout. Second, during the slow, pressure-limited part of each charge the logged volumetric flow rate alternates between zero and 0.5–1 SLPM, i.e., below the 1 SLPM lower limit of the controller. Integrating the readings as logged reproduces the absorbed masses reported with the data set; treating the zero readings as dropouts and interpolating across them gives 7–21% more (Table 1). The true absorbed mass was therefore taken to lie between these two bounds. Ambient temperature was estimated as the mean shell temperature at the end of each desorption log (25.3–26.2 °C), and the measured supply and cut-off pressures, initial bed temperatures and charge durations of each test were used as boundary conditions.
Table 1. Boundary conditions and observables of the three tests, derived from the time series of the open data set [31]. Pressures are absolute; temperatures are means of the five shell thermocouples, with single-thermocouple extremes in parentheses.

2.4. Reduced-Order Tank Model

The bed was represented as a cylinder of inner radius ri = 42.7 mm and effective length L = V/(πri2) = 0.442 m, so that the model volume equals the reported internal volume; axial gradients and end effects were neglected. With an alloy density of 6.1 g cm−3 the bed porosity is ε = 0.495, and the theoretical capacity corresponds to nmax = 68.1 mol H2 (137 g). The bed was divided into six annular finite volumes, each with a reacted fraction xj and temperature Tj, surrounded by a lumped steel shell of temperature Tw, which is compared with the mean thermocouple reading. The equilibrium pressure combines the van ’t Hoff term with a sloping plateau, a two-phase boundary term and hysteresis [26]:
ln Peqa,d = ln Peq,0 + (ΔH/R)(1/T0 − 1/T) + β(x − 0.5) + ζ ln[x/(1 − x)] ± η/2,
where x is the reacted fraction, T is the bed temperature, β is the plateau slope, ζ controls the width of the solid-solution and hydride single-phase regions, and η = ln(Pa/Pd) is the hysteresis factor (superscripts a and d denote absorption and desorption). The reaction rate follows an Avrami-type law with a logarithmic pressure driving force [8,37]:
dx/dt = kmCa exp(−Ea/RT) ln(P/Peqa) (1 − x) for P > Peqa,
dx/dt = −kmCd exp(−Ed/RT) ln(Peqd/P) x for P < Peqd,
where P is the gas pressure, with the pre-exponential factors and activation energies of Jemni and Ben Nasrallah (Ca = 59.2 s−1, Ea = 21.18 kJ mol−1, Cd = 9.57 s−1, Ed = 16.45 kJ mol−1) [8] scaled by a single multiplier km. The energy balance of volume j is
mjcp dTj/dt = Σ Gj,k(Tk − Tj) + nmax,j ΔH dxj/dt,
where mj is the alloy mass of volume j, cp = 480 J kg−1 K−1 is the specific heat of the alloy, Gj,k are radial conductances computed from an effective bed conductivity λeff, and the outermost volume exchanges heat with the shell through a contact coefficient hbw. The shell (10 kg, 500 J kg−1 K−1) loses heat to ambient air at Tamb through an external coefficient hout over 0.157 m2. Hydrogen in the void volume (εV plus 0.1 L of piping) is treated as an ideal gas at the mean bed temperature:
dng/dt = ṅin − Σj nmax,j dxj/dt, P = ngRT-/Vg.
Here ng is the amount of hydrogen in the void volume Vg, ṅin is the net molar flow of hydrogen into the tank (negative during discharge) and T- is the mean bed temperature. The test protocol is reproduced as logged. Charging starts from an evacuated bed at the measured initial temperature; the inflow equals the set flow until P reaches the measured supply pressure Psup, after which the pressure is held and the flow is set by absorption, for the measured charge duration. Where the log shows a rest, the closed tank relaxes towards Tamb. Discharge draws 5 SLPM until P falls to the measured cut-off Pcut, after which the pressure is held and the outflow is set by desorption. The stiff system of ordinary differential equations was integrated with a backward-differentiation solver (SciPy), and simulating one complete test takes about 0.3 s. This short run time, rather than that of a two- or three-dimensional solution, is what makes the analyses below practical: the calibration requires of the order of 104 simulations of complete tests, and the scenario, tolerance-window, screening and Sobol analyses a further ~3000 simulations of the design protocol.

2.5. Calibration and Validation

Nine parameters were estimated (Table 2): ln Peq,0 and ΔH of the tank alloy, β, ζ, η, λeff, hbw, hout and ln km. They were fitted to the 10 SLPM test by bounded weighted least squares (trust-region reflective algorithm) from four starting points, one of which was the composition-model prediction. Six residual blocks entered the objective, each residual being divided by the standard deviation σ assumed for the corresponding measurement, which sets its weight: shell temperature during charging (5 min resolution, σ = 2 °C), pressure during charging (σ = 0.7 bar), absorbed hydrogen every 30 min, penalized only outside the logged–dropout-corrected band (σ = 3 g), so that the dropout uncertainty enters the objective as an interval rather than as a point value, and shell temperature, pressure and delivered hydrogen during the first 6, 3 and 6 h of discharge (2 min resolution; σ = 2 °C, 0.5 bar and 2 g). Each block was scaled so that blocks of different length carry equal weight. The 5 and 15 SLPM tests were not used for calibration and serve as validation. Because the time-series residuals are strongly autocorrelated, formal confidence intervals from the Jacobian would be far too narrow.
Table 2. Parameters of the tank model: bounds used in calibration, estimates from the 10 SLPM test, the range over the 12 solutions fitted to the three tests, and the ranges used for the Sobol analysis.
Parameter uncertainty was therefore assessed empirically, by refitting the model separately to each of the three tests from the same starting points and retaining all solutions within 10% of the best objective (12 parameter sets), and by a profile of the objective over ln Peq,0, in which all other parameters were re-optimized at fixed plateau values. The calibrated plateau was then compared with the composition-model prediction and its AB2 error distribution, in the spirit of the calibration of computer models against observations [38].

2.6. Propagating Material Uncertainty to the Tank

All scenarios use a common design protocol based on the test rig: an evacuated tank at 26 °C is charged with a set flow of 10 SLPM and a 25.4 bar supply limit for 18 h, then discharged at 5 SLPM down to 1.4 bar for 7 h. Four key performance indicators (KPIs) were recorded: the hydrogen absorbed in 18 h, the hydrogen delivered, the minimum shell temperature during discharge and the time needed to absorb 60 g.
Scenarios: for each of the 12 calibrated parameter sets, the transport parameters were kept and the thermodynamics replaced by (A) the calibrated values, (B) the two nearest AB2 analogues in the database, Ti0.8Zr0.2CrMn and Zr0.2Ti0.8MnCr, (C0) the GBR point prediction and (C) the GBR prediction perturbed by nine randomly drawn AB2 out-of-fold residual pairs.
Sensitivity: first-order and total Sobol indices [39,40] were computed with SALib [41] for eight parameters, with ln Peq,0 and ΔH varied by ±1.75 and ±7 kJ mol−1 around the calibrated values (the AB2 cross-validation MAEs) and β, η, λeff, hout, km and hbw over wide engineering ranges (See Table 2).
Tolerance window and screening: ln Peq,0 and ΔH were varied on a grid around the calibrated values to map the region in which the KPIs stay within 10% of their calibrated values, and the calibrated tank was used to compare AB5 candidates from the La1−xCexNi5 and LaNi5−xAlx series using predicted and, where available, database thermodynamics.

3. Results

Figure 1 presented below summarizes the workflow. The composition model supplies a prediction, with an error model, for the equilibrium of the tank alloy, the tank model maps equilibrium and transport parameters to the logged pressure, temperature and flow, and the open tank data calibrate and validate it. The same tank model is then used as a common yardstick for the thermodynamic scenarios, the sensitivity analysis and the AB5 screen.
Figure 1. Workflow linking composition, equilibrium thermodynamics and tank performance. GBR, gradient-boosting regression. KPI, key performance indicator. SLPM, standard litres per minute.

3.1. Accuracy of Composition-Based Thermodynamics

Our Table 3 compares the two parameterizations. Over all 420 entries, the GBR model reaches an MAE of 7.2 kJ mol−1 in ΔH (R2 = 0.62) and of 2.03 in ln Peq at 298 K. Restricted to the 345 entries with |ln Peq| < 6, i.e., plateaus between about 0.0025 and 410 bar, the MAE falls to 1.33 at 298 K and 1.19 at 348 K. The van ’t Hoff-consistent scheme is better than the independent scheme in every case, but only by 0.04–0.05 in ln Peq; the gain is consistent across repeated splits and both learners, yet it is small compared with the error itself. Random forests are slightly worse than GBR. As in earlier work [22], the most important descriptors for both targets are the mean and mode of the elemental ground-state volume per atom, followed by covalent radius and d-shell filling, which reflects the interstitial-volume control of hydride stability.
Table 3. Cross-validated accuracy of the equilibrium models (5-fold, three repeats; mean over repeats). The window subset contains the 345 entries with |ln Peq,0| < 6.
Accuracy depends strongly on the alloy class (Figure 2c, Table 4). AB5 compounds, the most homogeneous and best-sampled class, are predicted to within 0.90 in ln Peq and 3.3 kJ mol−1 in ΔH. AB2 Laves phases, which are more numerous but chemically diverse, have twice the error (1.75 and 7.0 kJ mol−1), and Mg-based, AB and multicomponent compounds are worse still. When an entire class is withheld, the error grows to 2.12 for AB5 and to 3.89 for AB2, with a systematic underprediction of the plateau (mean signed error −1.42 and −3.23, respectively). For the AB2 out-of-fold residuals, the standard deviations are 3.05 in ln Peq and 10.3 kJ mol−1 in ΔH, with a correlation of −0.60 between the two errors: this distribution is the error model carried forward to the tank.
Figure 2. Composition-based equilibrium models. (a) Out-of-fold predicted versus reported ΔH; (b) out-of-fold predicted versus reported ln Peq at 298 K, coloured by alloy class; (c) mean absolute error of ln Peq by class for random cross-validation (filled) and with the class withheld from training (hatched).
Table 4. Class-resolved out-of-fold errors of the GBR model (van ’t Hoff scheme) and leave-class-out errors.
For the tank alloy Ti0.815Zr0.185Cr0.77Fe0.07Mn0.88, which is not in the database, the model predicts ΔH = 26.7 kJ mol−1 and ln Peq,0 = 0.63, i.e., a plateau of about 1.9 bar at 298 K and ΔS = 94.9 J mol−1 K−1. The two nearest database analogues bracket this prediction: Ti0.8Zr0.2CrMn (ΔH = 24.6 kJ mol−1, ln Peq,0 = 3.17) and Zr0.2Ti0.8MnCr (30.0 kJ mol−1, 1.80). The spread between these two related compositions, 1.4 units in ln Peq,0, is itself comparable to the class error.

3.2. Calibration and Validation of the Tank Model

All four starting points of the 10 SLPM fit converged to nearly the same solution (objective 153.8–155.8), including the start at the composition-model prediction (ln Peq,0 = 0.63). The estimates are listed in Table 2. The plateau, ln Peq,0 = 2.68, and ΔH = 28.9 kJ mol−1 are well-defined; together they give ΔS ≈ 119 J mol−1 K−1, a typical value for AB2 hydrides. The tank also fixes a moderately sloping plateau (β ≈ 0.5), hysteresis η ≈ 0.3 and an external heat-transfer coefficient of 6.8 W m−2 K−1, consistent with natural convection and radiation from a bare cylinder in still air. Bed conductivity and bed–wall contact move to their upper bounds, i.e., the data are best described with negligible internal resistance (at the fitted values the external resistance, 1/(hout Aout) ≈ 0.94 K W−1, is 20–30 times the combined bed and contact resistance, so the objective is nearly flat in λeff and hbw), and the kinetic multiplier is not identified (0.05–1.1 across fits): with a supply-limited charge and a slow discharge, the tank operates close to equilibrium and its heat balance, not its kinetics, sets the rates.
For the 10 SLPM calibration test, the root-mean-square errors are 3.3 °C for shell temperature and 0.4 bar for pressure during charging, and 2.6 °C, 0.6 bar and 1.7 g for temperature, pressure and delivered hydrogen during the first hours of discharge. Figure 3 compares the calibrated model with all three tests. Without refitting, the 5 and 15 SLPM tests are reproduced with errors of 5.5 and 3.6 °C (charging temperature), 1.0 and 0.4 bar (charging pressure), 4.4 and 3.5 °C (discharge temperature), 0.9 and 0.7 bar (discharge pressure) and 2.6 and 1.8 g (delivered hydrogen). The minimum mean shell temperature during discharge is predicted within 1.3 °C in all tests (−10.0 to −11.1 °C against −9.6 to −12.4 °C at 5 min resolution).
Figure 3. Calibrated tank model (red) against the three tests (black). Rows: mean shell temperature during charging; hydrogen absorbed, with the band between logged and dropout-corrected flow; mean shell temperature during discharge, with the range of the five thermocouples; hydrogen delivered (solid) and absolute pressure (dotted) during discharge. Parameters were fitted to the 10 SLPM test only.
Even so, two systematic deviations remain. The peak shell temperature during the set-flow phase is underpredicted by 11–15 °C, because the bed equilibrium temperature at the supply pressure is set by the low-concentration part of the isotherm, which the simple form of Equation (2) represents poorly; the long cooling tail that controls the absorbed amount is, however, reproduced. The model also predicts a concave absorption curve, whereas the logged uptake stalls between about 4 and 10 h and then accelerates. The stall coincides with the period in which the flow readings fall below the controller’s rated range, and the corrected band in Figure 3 shows that much of it is a metering artefact, but the late acceleration is not captured.

3.3. What the Tank Implies for the Composition Model

The plateau is the best-determined parameter of the tank. Refitting to each test separately gives ln Peq,0 = 2.67 (5 SLPM), 2.68 (10 SLPM) and 2.59 (15 SLPM), and the 12 solutions within 10% of the best objective span 2.59–2.68, i.e., 13.5–14.8 bar at 298 K; ΔH spans 27.2–29.6 kJ mol−1 (Figure 4b). The profile in Figure 4a rises steeply on both sides of its minimum: fixing the plateau 0.25 units too low or too high raises the objective by 69 and 20 units, respectively, and at the GBR prediction the objective is about 35 times its minimum. Compared with these estimates, the GBR model predicts ΔH almost correctly (26.7 kJ mol−1) but places the plateau 2.0 units too low, a factor of about 7 in pressure, the error lies almost entirely in the entropy term. The direction of the error matches the systematic underprediction found when AB2 alloys were withheld (See Table 4), and its size is within the 1σ ellipse of the AB2 error model. In other words, the prediction is wrong by an amount the model itself declares plausible, and three ordinary tank tests constrain the plateau roughly two orders of magnitude more tightly than the composition model does.
Figure 4. Plateau of the tank alloy. (a) Profile of the calibration objective over ln Peq,0, black line and markers (all other parameters re-optimized, symmetric-log scale), with the separate fits to the three tests (vertical lines; the inset enlarges the region around the minimum) and the GBR prediction with its AB2 1σ interval (one standard deviation, σ, of the AB2 out-of-fold residuals). (b) Calibrated solutions (red) in the (ln Peq,0, ΔH) plane, the GBR prediction with its 1σ (solid) and 2σ (dashed) AB2 error ellipses, and the two nearest database analogues (grey squares).

3.4. Propagation of Material-Level Uncertainty to the Tank

Table 5 and next Figure 5 compare the design protocol for the 12 calibrated transport parameter sets under different thermodynamic inputs. With the calibrated thermodynamics (A), the tank absorbs 79 g in 18 h, needs 8.8 h to take up 60 g, peaks at 58 °C and delivers 69 g at 5 SLPM, its shell falling to −11 °C. The nearest database analogues behave quite differently in the same vessel. Ti0.8Zr0.2CrMn (B1), with a plateau 0.5 units higher, is held back by the supply pressure and absorbs only 55 g, never reaching 60 g. Zr0.2Ti0.8MnCr (B2), 0.8 units lower, absorbs 118 g and reaches 60 g in 3.8 h, and because it stores more it delivers almost as much as A (65 g). The GBR point prediction (C0) behaves like a much more stable hydride: the tank takes up 60 g in 1.1 h and reaches its theoretical capacity during the charge, the shell reaches 106 °C, and only 47 g of the 139 g stored are delivered before the cold bed reaches the cut-off pressure, 31% less than with the calibrated values. When the GBR prediction is perturbed by AB2 cross-validation errors (C), the 5–95% interval of delivered hydrogen spans 3 to 106 g, and only 6 of 108 draws fall within ±10% of the calibrated delivery.
Table 5. Tank KPIs for the design protocol under different thermodynamic inputs: median (5–95% interval) over the calibrated transport parameter sets.
Figure 5. Distributions of (a) hydrogen delivered at 5 SLPM, (b) hydrogen absorbed in an 18 h charge and (c) minimum shell temperature during discharge under the thermodynamic scenarios of Table 5. Boxes show quartiles and whiskers the 5–95% range.

3.5. Tolerance Window and Sensitivity

Delivery is a non-monotonic function of the plateau. Figure 6a maps the delivered hydrogen over offsets of ln Peq,0 and ΔH from the calibrated values. It peaks (73 g) for a plateau 0.5 units lower than calibrated, because a more stable hydride stores more during the supply-limited charge, and it falls steeply for higher plateaus, which leave the tank partly empty. Delivery stays within 10% of its calibrated value (68.2 g) for offsets from −1.46 to +0.24, a window of 1.71 units that is strongly asymmetric: an overestimated plateau is far more costly than an underestimated one. The charging behaviour is much less tolerant. The hydrogen absorbed in 18 h stays within ±10% only for plateau offsets between −0.15 and +0.15, and an offset of ±0.25 changes the time to absorb 60 g from 8.7 h to 6.2 and 13.8 h. Along the ΔH axis at fixed plateau, delivery stays within 10% for any lower enthalpy and up to +3.1 kJ mol−1 higher, and the absorbed amount for offsets between −5.5 and +5.0 kJ mol−1. For comparison, the half-width of the delivery window (0.85) is about equal to the AB5 cross-validation MAE (0.90) and half the AB2 MAE (1.75), whereas the absorption window is six and twelve times narrower than these errors.
Figure 6. (a) Hydrogen delivered at 5 SLPM under the design protocol as a function of offsets in ln Peq,0 and ΔH from the calibrated values, the white contour encloses delivery within 90% of the calibrated value, ellipses show the 1σ cross-validation errors of the AB2 (red) and AB5 (orange) models, and the star marks the GBR prediction for the tank alloy. (b) Total Sobol indices of four tank KPIs with thermodynamic uncertainty equal to the AB2 MAEs and transport parameters varied over the ranges of Table 2.
The Sobol indices in Figure 6b express the same point globally. With the thermodynamics varied by ±1.75 in ln Peq,0 and ±7 kJ mol−1 in ΔH (the AB2 MAEs) and the transport parameters over the ranges in Table 2, the plateau alone carries total indices of 0.98 for absorbed hydrogen, 0.96 for the time to absorb 60 g, 0.88 for delivered hydrogen and 0.80 for the minimum shell temperature. The external coefficient hout is the only other parameter of consequence (0.15 for delivery and 0.11 for minimum temperature); ΔH contributes at most 0.08, and β, η, λeff, km and hbw at most 0.06. The 95% bootstrap confidence intervals are at most ±0.15 (2560 model runs, none failed; runs that did not take up 60 g within 18 h, 38% of the total, were assigned the longest time observed).

3.6. Virtual Screening of AB5 Substitution Series

To illustrate how the calibrated tank can be used despite these limits, the AB2 charge was replaced by the same packed volume of AB5 alloy (10.8 kg, 1.4 wt%; β = 0.25, η = 0.25 and LaNi5 kinetics [8]), keeping the vessel, heat exchange and design protocol fixed. The GBR model predicts plateaus at 298 K that rise from 1.5 bar for LaNi5 to 3.3, 3.8, 3.9 and 6.9 bar for La1−xCexNi5 with x = 0.1, 0.2, 0.25 and 0.5, and fall to 1.1, 0.83, 0.50, 0.37, 0.26 and 0.09 bar for LaNi5−xAlx with x = 0.1, 0.2, 0.3, 0.4, 0.55 and 0.75. With predicted thermodynamics every candidate fills the tank to about 154 g in the 18 h charge, but the hydrogen delivered at 5 SLPM without heating follows the plateau monotonically (See Figure 7): 20 g for LaNi5, 59–69 g for xCe = 0.1–0.25, 102 g for La0.5Ce0.5Ni5, and 3–10 g for the Al-substituted alloys. Where database thermodynamics exist they change the absolute numbers (50 g instead of 20 g for LaNi5, whose database plateau is 0.7 units higher) but not the ranking. With the 25 bar supply the AB5 beds would reach 67–173 °C during charging, so a real AB5 design would also lower the supply pressure or add cooling.
Figure 7. Virtual screening of AB5 alloys in the calibrated tank under the design protocol. (a) Hydrogen absorbed in 18 h and delivered at 5 SLPM with GBR-predicted thermodynamics, where crosses show delivery with database thermodynamics where available. (b) Delivered hydrogen versus predicted ln Peq,0. The AB2 point uses the GBR prediction for the tank alloy, not the calibrated value.

4. Discussion

4.1. How Accurate Must Predicted Thermodynamics Be?

For this tank the answer depends on which decision the prediction is meant to support. If the question is how much hydrogen a full charge will deliver without heating, the room-temperature plateau must be known to within roughly −1.5/+0.25 in ln Peq; the window is asymmetric because an overestimated plateau leaves the tank under-filled, while a moderately underestimated one is compensated by a larger stored amount. If the question is how much hydrogen an 18 h charge stores, how long it takes or how hot the bed becomes, the plateau must be known to within about ±0.15, i.e., ±15% in pressure. The best class-resolved accuracy available from composition alone is 0.90 for AB5 and 1.75 for AB2, and nearly 4 when the composition lies outside the well-sampled part of the class. Composition models are therefore close to adequate for a first estimate of deliverable capacity of AB5 alloys, but they are six to twelve times too coarse for predicting how a supply-limited tank charges. This gap cannot be closed by better transport modelling: once the plateau is uncertain at this level it dominates every KPI (Figure 6b). The specific numbers depend on the vessel, its heat exchange and its pressure limits. The method for obtaining them, a calibrated tank model plus a tolerance map, transfers directly to other vessels.
The tank alloy also illustrates where the composition-model error comes from. The predicted enthalpy is within 2 kJ mol−1 of the calibrated value, while the plateau is off by 2.0 units; the error therefore sits in the entropy, which composition descriptors capture poorly and which the database reports with considerable scatter between nominally similar alloys. Ti0.815Zr0.185Cr0.77Fe0.07Mn0.88 is A-rich (B/A ≈ 1.72) and Fe-substituted, and the closest database entries differ from each other by 1.4 units in ln Peq,0. A model trained on such data cannot be expected to resolve plateau differences of a few tenths for this class. Reporting class-resolved and leave-class-out errors, as done here, at least makes this visible to the user.
None of this makes composition models useless for system design. Their errors are large in absolute terms but largely systematic within a substitution series, so rankings survive: in Figure 7 the predicted order of the La–Ce–Ni and La–Ni–Al alloys is unchanged when database values replace predictions. The screen also reproduces the design logic of systems built around these alloys. Ce substitution raises the plateau and is the route to unheated delivery at fuel-cell pressures [16]. Al substitution lowers it, which is useful for absorbing near-atmospheric hydrogen from solid-oxide electrolysers but requires heating to 90–120 °C for release [18]; in an unheated tank these alloys deliver almost nothing. A practical division of labour follows: use composition models to choose the substitution direction and narrow a series to two or three candidates, then fix ln Peq with one measured isotherm before committing to a vessel design. Section 3.3 shows that a few well-logged tank tests interpreted through a calibrated model can serve the same purpose.

4.2. Heat Transfer in Context

The calibrated tank operates close to equilibrium. Its charge is limited by the supply pressure and its discharge by the cut-off pressure, and in both cases the rate is set by how fast heat crosses the outer surface (hout ≈ 6–7 W m−2 K−1). Bed conductivity and bed–wall contact moved to the upper bounds of the fit, and the kinetic multiplier was not identified. This should not be read as a general statement that bed heat transfer or kinetics are unimportant, which would contradict a large body of work [10,11,12]. It means that in a bare vessel cooled by still air the external resistance dominates, so internal enhancements cannot change the outcome.
The same calibration shows where engineering effort would pay: the external coefficient is the only transport parameter with a substantial Sobol index, and a finned shell or water jacket would both shorten the charge and widen the plateau tolerance window. Thermal management and material selection can be traded against each other, but only once both are quantified on the same model.

4.3. Limitations

The calibration uses one tank and three tests. Within that scope, it identifies the plateau, enthalpy, plateau slope, hysteresis and external heat transfer, but not the internal transport parameters, two of which (λeff, hbw) and the phase-boundary term ζ ended at their bounds. These should be read as effective values that absorb model-form error: the lumped shell is compared with the mean of five surface thermocouples, axial conduction and the end caps are neglected, and Equation (2) is a simple isotherm form. The latter is the most likely cause of the two systematic deviations in Figure 3: the 11–15 °C underprediction of the peak shell temperature, which is set by the low-concentration part of the isotherm, and the missing late acceleration of the absorption curve. The thermocouples also show a plateau near −10 °C between about 1.5 and 4 h of each discharge that the model does not reproduce; frost formation on the cold shell would produce such a plateau, but the data do not allow this to be confirmed. The absorbed masses are uncertain by 7–21% because the controller operated below its rated range during most of each charge, and the sub-second dynamics of the controller are not modelled.
The ensemble of 12 fitted parameter sets is a pragmatic substitute for a full posterior. On the material side, ML-HydPARK contains few sub-stoichiometric Ti–Zr–Cr–Mn–Fe Laves phases, and its entries come from different measurement protocols, so part of the cross-validation error is data noise rather than model error. Finally, the AB5 screen keeps the AB2 vessel and supply pressure, under which AB5 beds would overheat, and it is meant to rank alloys, not to design an AB5 tank.
These two extensions follow directly. A more flexible isotherm, for example one derived from a phase-equilibrium model [26], fitted jointly to tank and PCT data, would remove most of the remaining systematic error. And because the framework expresses every material uncertainty in tank-level units, it can rank candidate experiments (a PCT isotherm, a second tank test, a different flow rate) by how much they would reduce the uncertainty of a design decision.

5. Conclusions

We linked composition-based predictions of hydride thermodynamics to a physics-based model of a 7.8 kg AB2 tank, calibrated on the pressure, temperature and flow time series of one open test and validated on two others, and used the link to ask how accurate the predictions must be for tank-level decisions. Gradient-boosting models trained on 420 ML-HydPARK entries predict the room-temperature plateau with cross-validated MAEs of 0.90 (AB5) and 1.75 (AB2) in ln Peq. The calibrated tank model reproduces the validation tests within 3.5–5.5 °C and 0.4–1.0 bar and places the alloy’s plateau at ln Peq,0 = 2.59–2.68, 2.0 units above the composition-model prediction, while the predicted enthalpy is nearly correct. Substituting the predicted thermodynamics changes the simulated tank qualitatively: it takes up 60 g in about one hour instead of nine, overheats to 106 °C and delivers 31% less hydrogen. Delivered capacity tolerates plateau errors of about −1.5/+0.25, whereas charging behaviour tolerates only ±0.15, and the plateau dominates the variance of every KPI. Composition models are therefore useful for ranking substitution series, as the La–Ce–Ni and La–Ni–Al screen shows, but a measured isotherm, or well-logged tank tests interpreted through a calibrated model, remains necessary before tank performance can be predicted.

Author Contributions

Conceptualization, A.K. and D.C.; methodology, A.K. and F.N.; software, A.K. and F.N.; validation, A.K. and F.N.; formal analysis, A.K. and F.N.; investigation, A.K. and F.N.; data curation, F.N.; writing—original draft preparation, A.K.; writing—review and editing, A.K., F.N. and D.C.; visualization, A.K. and F.N.; supervision, D.C.; project administration, D.C. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Data Availability Statement

This study analyzed publicly available data. The hydride thermodynamics are from ML-HydPARK v0.0.5 (https://doi.org/10.5281/zenodo.10680097) [19], and the tank time series are from Mendeley Data (https://doi.org/10.17632/8km9z62tct.1) [31]. The code for the equilibrium models, the tank model, the calibration and the sensitivity analysis, together with the processed data and the figures, is openly available at https://github.com/akartbayev/mh-composition-to-tank (accessed on 16 November 2026).

Acknowledgments

The authors thank the creators of the ML-HydPARK database and of the open AB2 tank data set for making their data publicly available. During the preparation of this manuscript, the authors used NotebookLM, Google Cloud Platform (GCP) and Gemini for the purposes of language editing, and Qwen3.8-27B and Visual Studio Code (v1.147.0) for the purposes of coding. The authors have reviewed and edited the output and take full responsibility for the content of this publication.

Conflicts of Interest

The authors declare no conflicts of interest.

Abbreviations

The following abbreviations are used in this manuscript:
CVCross-validation
GBRGradient-boosting regression
KPIKey performance indicator
MAEMean absolute error
MHMetal hydride
MICMulticomponent intermetallic compound
PCTPressure–composition–temperature
RMSERoot-mean-square error
RFRandom forest
SLPMStandard litres per minute
SSSolid solution
TCThermocouple

References

  1. Schlapbach, L.; Züttel, A. Hydrogen-storage materials for mobile applications. Nature 2001, 414, 353–358. [Google Scholar] [CrossRef] [Scilit]
  2. Sakintuna, B.; Lamari-Darkrim, F.; Hirscher, M. Metal hydride materials for solid hydrogen storage: A review. Int. J. Hydrogen Energy 2007, 32, 1121–1140. [Google Scholar] [CrossRef] [Scilit]
  3. Hirscher, M.; Yartys, V.A.; Baricco, M.; Bellosta von Colbe, J.; Blanchard, D.; Bowman, R.C., Jr.; Broom, D.P.; Buckley, C.E.; Chang, F.; Chen, P.; et al. Materials for hydrogen-based energy storage—Past, recent progress and future outlook. J. Alloys Compd. 2020, 827, 153548. [Google Scholar] [CrossRef] [Scilit]
  4. Klopčič, N.; Grimmer, I.; Winkler, F.; Sartory, M.; Trattner, A. A review on metal hydride materials for hydrogen storage. J. Energy Storage 2023, 72, 108456. [Google Scholar] [CrossRef] [Scilit]
  5. Bellosta von Colbe, J.; Ares, J.-R.; Barale, J.; Baricco, M.; Buckley, C.; Capurso, G.; Gallandat, N.; Grant, D.M.; Guzik, M.N.; Jacob, I.; et al. Application of hydrides in hydrogen storage and compression: Achievements, outlook and perspectives. Int. J. Hydrogen Energy 2019, 44, 7780–7808. [Google Scholar] [CrossRef] [Scilit]
  6. Lototskyy, M.V.; Yartys, V.A.; Pollet, B.G.; Bowman, R.C., Jr. Metal hydride hydrogen compressors: A review. Int. J. Hydrogen Energy 2014, 39, 5818–5851. [Google Scholar] [CrossRef] [Scilit]
  7. Lototskyy, M.V.; Davids, M.W.; Tolj, I.; Klochko, Y.V.; Sekhar, B.S.; Chidziva, S.; Smith, F.; Swanepoel, D.; Pollet, B.G. Metal hydride systems for hydrogen storage and supply for stationary and automotive low temperature PEM fuel cell power modules. Int. J. Hydrogen Energy 2015, 40, 11491–11497. [Google Scholar] [CrossRef] [Scilit]
  8. Jemni, A.; Ben Nasrallah, S. Study of two-dimensional heat and mass transfer during absorption in a metal-hydrogen reactor. Int. J. Hydrogen Energy 1995, 20, 43–52. [Google Scholar] [CrossRef] [Scilit]
  9. Muthukumar, P.; Prakash Maiya, M.; Srinivasa Murthy, S. Experiments on a metal hydride-based hydrogen storage device. Int. J. Hydrogen Energy 2005, 30, 1569–1581. [Google Scholar] [CrossRef] [Scilit]
  10. MacDonald, B.D.; Rowe, A.M. Impacts of external heat transfer enhancements on metal hydride storage tanks. Int. J. Hydrogen Energy 2006, 31, 1721–1731. [Google Scholar] [CrossRef] [Scilit]
  11. Nam, J.; Ko, J.; Ju, H. Three-dimensional modeling and simulation of hydrogen absorption in metal hydride hydrogen storage vessels. Appl. Energy 2012, 89, 164–175. [Google Scholar] [CrossRef] [Scilit]
  12. Afzal, M.; Mane, R.; Sharma, P. Heat transfer techniques in metal hydride hydrogen storage: A review. Int. J. Hydrogen Energy 2017, 42, 30661–30682. [Google Scholar] [CrossRef] [Scilit]
  13. Sandrock, G. A panoramic overview of hydrogen storage alloys from a gas reaction point of view. J. Alloys Compd. 1999, 293–295, 877–888. [Google Scholar] [CrossRef] [Scilit]
  14. Joubert, J.-M.; Paul-Boncour, V.; Cuevas, F.; Zhang, J.; Latroche, M. LaNi5 related AB5 compounds: Structure, properties and applications. J. Alloys Compd. 2021, 862, 158163. [Google Scholar] [CrossRef] [Scilit]
  15. Lys, A.; Fadonougbo, J.O.; Faisal, M.; Suh, J.-Y.; Lee, Y.-S.; Shim, J.-H.; Park, J.; Cho, Y.W. Enhancing the hydrogen storage properties of AxBy intermetallic compounds by partial substitution: A short review. Hydrogen 2020, 1, 38–63. [Google Scholar] [CrossRef] [Scilit]
  16. Son, V.B.; Shimkus, Y.Y.; Mozhzhukhin, S.A.; Bocharnikov, M.S.; Fokina, E.E.; Tarasov, B.P. Application of intermetallics (La,Ce)Ni5 in hydrogen energy storage systems. Russ. J. Appl. Chem. 2020, 93, 1380–1386. [Google Scholar] [CrossRef] [Scilit]
  17. Tarasov, B.P.; Arbuzov, A.A.; Volodin, A.A.; Fursikov, P.V.; Mozhzhuhin, S.A.; Lototskyy, M.V.; Yartys, V.A. Metal hydride—Graphene composites for hydrogen based energy storage. J. Alloys Compd. 2022, 896, 162881. [Google Scholar] [CrossRef] [Scilit]
  18. Tarasov, B.; Arbuzov, A.; Mozhzhukhin, S.; Volodin, A.; Fursikov, P.; Davids, M.W.; Adeniran, J.; Lototskyy, M. Metal hydride hydrogen storage (compression) units operating at near-atmospheric pressure of the feed H2. Inorganics 2023, 11, 290. [Google Scholar] [CrossRef] [Scilit]
  19. Witman, M.; Allendorf, M.; Stavila, V. Database for Machine Learning of Hydrogen Storage Materials Properties, Version 0.0.5. Zenodo, 2024. Available online: https://zenodo.org/records/10680097 (accessed on 16 November 2026).
  20. Hattrick-Simpers, J.R.; Choudhary, K.; Corgnale, C. A simple constrained machine learning model for predicting high-pressure-hydrogen-compressor materials. Mol. Syst. Des. Eng. 2018, 3, 509–517. [Google Scholar] [CrossRef] [Scilit]
  21. Rahnama, A.; Zepon, G.; Sridhar, S. Machine learning based prediction of metal hydrides for hydrogen storage, part I: Prediction of hydrogen weight percent. Int. J. Hydrogen Energy 2019, 44, 7337–7344. [Google Scholar] [CrossRef] [Scilit]
  22. Witman, M.; Ling, S.; Grant, D.M.; Walker, G.S.; Agarwal, S.; Stavila, V.; Allendorf, M.D. Extracting an empirical intermetallic hydride design principle from limited data via interpretable machine learning. J. Phys. Chem. Lett. 2020, 11, 40–47. [Google Scholar] [CrossRef] [Scilit]
  23. Witman, M.D.; Ling, S.; Wadge, M.; Bouzidi, A.; Pineda-Romero, N.; Clulow, R.; Ek, G.; Chames, J.M.; Allendorf, E.J.; Agarwal, S.; et al. Towards Pareto optimal high entropy hydrides via data-driven materials discovery. J. Mater. Chem. A 2023, 11, 15878–15888. [Google Scholar] [CrossRef] [Scilit]
  24. Wilson, N.; Verma, A.; Maharana, P.R.; Sahoo, A.B.; Joshi, K. HyStor: An experimental database of hydrogen storage properties for various metal alloy classes. Int. J. Hydrogen Energy 2024, 90, 460–469. [Google Scholar] [CrossRef] [Scilit]
  25. Beltrame, G.; Dematteis, E.M.; Stavila, V.; Rizzi, P.; Baricco, M.; Palumbo, M. Application of machine learning and data augmentation algorithms in the discovery of metal hydrides for hydrogen storage. Metals 2025, 15, 1221. [Google Scholar] [CrossRef] [Scilit]
  26. Lototskyy, M.V. New model of phase equilibria in metal–hydrogen systems: Features and software. Int. J. Hydrogen Energy 2016, 41, 2739–2761. [Google Scholar] [CrossRef] [Scilit]
  27. Raissi, M.; Perdikaris, P.; Karniadakis, G.E. Physics-informed neural networks: A deep learning framework for solving forward and inverse problems involving nonlinear partial differential equations. J. Comput. Phys. 2019, 378, 686–707. [Google Scholar] [CrossRef] [Scilit]
  28. Karniadakis, G.E.; Kevrekidis, I.G.; Lu, L.; Perdikaris, P.; Wang, S.; Yang, L. Physics-informed machine learning. Nat. Rev. Phys. 2021, 3, 422–440. [Google Scholar] [CrossRef] [Scilit]
  29. Rackauckas, C.; Ma, Y.; Martensen, J.; Warner, C.; Zubov, K.; Supekar, R.; Skinner, D.; Ramadhan, A.; Edelman, A. Universal differential equations for scientific machine learning. arXiv 2020, arXiv:2001.04385. [Google Scholar]
  30. Neves, A.M.; Großmann, W.; Puszkiel, J.A.; Warfsmann, J.; Hosseini, V.R.; Passing, M.; Carraro, T.; Klassen, T.; Niggemann, O.; Jepsen, J. Kinetic-model identification in metal-hydride reactions using neural network autoencoder surrogate models. Energy AI 2025, 22, 100659. [Google Scholar] [CrossRef] [Scilit]
  31. Ramadhan, F.; Suwarno, S.; Hijriawan, M. Experimental Dataset on the Absorption–Desorption Dynamics of an AB2 Metal Hydride Hydrogen Storage Tank for a 300 Watt PEM Fuel Cell. Mendeley Data, V1, 2026. Available online: https://data.mendeley.com/datasets/8km9z62tct/1 (accessed on 16 November 2026).
  32. Ong, S.P.; Richards, W.D.; Jain, A.; Hautier, G.; Kocher, M.; Cholia, S.; Gunter, D.; Chevrier, V.L.; Persson, K.A.; Ceder, G. Python Materials Genomics (pymatgen): A robust, open-source python library for materials analysis. Comput. Mater. Sci. 2013, 68, 314–319. [Google Scholar] [CrossRef] [Scilit]
  33. Ward, L.; Dunn, A.; Faghaninia, A.; Zimmermann, N.E.R.; Bajaj, S.; Wang, Q.; Montoya, J.; Chen, J.; Bystrom, K.; Dylla, M.; et al. Matminer: An open source toolkit for materials data mining. Comput. Mater. Sci. 2018, 152, 60–69. [Google Scholar] [CrossRef] [Scilit]
  34. Ward, L.; Agrawal, A.; Choudhary, A.; Wolverton, C. A general-purpose machine learning framework for predicting properties of inorganic materials. npj Comput. Mater. 2016, 2, 16028. [Google Scholar] [CrossRef] [Scilit]
  35. Friedman, J.H. Greedy function approximation: A gradient boosting machine. Ann. Stat. 2001, 29, 1189–1232. [Google Scholar] [CrossRef] [Scilit]
  36. Pedregosa, F.; Varoquaux, G.; Gramfort, A.; Michel, V.; Thirion, B.; Grisel, O.; Blondel, M.; Prettenhofer, P.; Weiss, R.; Dubourg, V.; et al. Scikit-learn: Machine learning in Python. J. Mach. Learn. Res. 2011, 12, 2825–2830. Available online: https://dl.acm.org/doi/10.5555/1953048.2078195 (accessed on 16 November 2026).
  37. Avrami, M. Kinetics of phase change. I. General theory. J. Chem. Phys. 1939, 7, 1103–1112. [Google Scholar] [CrossRef] [Scilit]
  38. Kennedy, M.C.; O’Hagan, A. Bayesian calibration of computer models. J. R. Stat. Soc. Ser. B Stat. Methodol. 2001, 63, 425–464. [Google Scholar] [CrossRef] [Scilit]
  39. Sobol’, I.M. Global sensitivity indices for nonlinear mathematical models and their Monte Carlo estimates. Math. Comput. Simul. 2001, 55, 271–280. [Google Scholar] [CrossRef] [Scilit]
  40. Saltelli, A.; Annoni, P.; Azzini, I.; Campolongo, F.; Ratto, M.; Tarantola, S. Variance based sensitivity analysis of model output. Design and estimator for the total sensitivity index. Comput. Phys. Commun. 2010, 181, 259–270. [Google Scholar] [CrossRef] [Scilit]
  41. Herman, J.; Usher, W. SALib: An open-source Python library for sensitivity analysis. J. Open Source Softw. 2017, 2, 97. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.