Abstract
Hydrogen (H2) is a common product of carbohydrate fermentation by the intestinal microbiota, transferred to the blood along the pressure gradient, and exhaled. As H2 is not produced or metabolized in human cells, alveolar H2 is distributed throughout the human body, including cellular organelles such as mitochondria, owing to systemic circulation and gas exchange. The electron transport chain comprises a series of oxidation–reduction (redox) enzymes in the mitochondria of human cells that facilitate adenosine triphosphate (ATP) synthesis. The catalytic activity of electron-transport enzymes is optimized at certain electrochemical potentials, as is hydrogen ion activity (pH). However, the human body is an aqueous system that must be electrically neutral. Membrane potentials exist between the interior and exterior of human cells because of the unequal distribution of ions across the membrane. The single-electrode potential can only be assessed relative to that of another electrode (i.e., a reference electrode). The electrochemical potentials relative to a standard hydrogen electrode (SHE) were measured; it was found that H2 partial pressure was a fundamental factor that affected the SHE, pH, and the reversible hydrogen electrode. The H2 partial pressure is not a unit used to characterize the human body; therefore, breath H2 is an external variable in the redox environment in the human body.
1. Introduction
Molecular hydrogen (H2) is the second most abundant reduced gas on Earth following methane and has a relatively uniform concentration of 530 parts per billion (ppb) in the atmosphere owing to large-scale atmospheric circulation. Photochemical oxidation of methane and non-methane organic compounds in the atmosphere is considered the dominant source of H2, while the primary sinks include soil uptake and reactions with hydroxyl radicals occurring in the atmosphere [1,2,3]. For a long time, H2 was thought to be a “biologically inert gas” that could not react with biomolecules under normal pressure [4]. An inert gas is defined as one that dissolves in the blood and tissues in a manner that can be described by Henry’s Law, undergoes no change in chemical identity during its passage through the organism, and is therefore quantitatively recoverable from the organism at any time. This definition includes those volatile anesthetic agents that are not chemically altered in the body even though they produce definite physiological effects [5]. In cultured cells under acute oxidative stress, H2 selectively scavenged hydroxyl radicals and effectively protected the cells; however, H2 did not react with other reactive oxygen species that possess physiological roles [6]. The rate constant for the reaction of the hydroxyl radical with H2 in aqueous solution was reported to be 3.4 × 107 dm3 mol−1 s−1 at 20 °C [7]. Notably, H2 can be measured in flatus and exhaled breath as it is a common product of carbohydrate fermentation by the gut microbiota. Before ingesting a carbohydrate, the healthy fasting breath H2 concentration is typically less than 16 parts per million (ppm), with a mean value of approximately 7 ppm [8]. A breath H2 test does not measure blood H2 or colonic H2 concentrations. However, when the blood leaves the lungs, arterial H2 partial pressure (PaH2) is in equilibrium with the alveolar gas and alveolar H2 partial pressure (PAH2) [9].
PaH2 = PAH2
CO2, for instance, is produced in tissues and similarly moves into the blood along a pressure gradient before diffusing into the alveoli. However, given that the functional residual capacity of the lungs (the volume of air remaining at the end of a normal exhalation) is 2300 mL and the tidal volume is 500 mL with a dead space of 150 mL, a single breath replaces approximately 1/7th of the alveolar gas [10]. Consequently, CO2 partial pressure (PCO2) in the alveoli is higher than that of the atmosphere, with a value of 40 mmHg. When blood leaves the lungs, arterial PCO2 is 40 mmHg. H2 gas behaves similarly; PH2 in the alveoli (at the end of exhalation) equilibrates with arterial PH2. If PH2 in the tissues is low, it diffuses from the blood into the tissues; conversely, if tissue PH2 is high, it diffuses into the blood. Diffusion continues as long as gas is present, resulting in a dynamic equilibrium analogous to a saturated tissue state.
The H2 partial pressure in the human body can be mathematically estimated using the end-tidal H2 concentration in breath. As H2 is not electrically charged and is not biologically metabolized in human cells, it can diffuse from the intestinal space to the blood, organs, and alveolar space [11]. According to Henry’s law, the amount of gas dissolved in a solution is proportional to its partial pressure when the solution is at equilibrium. However, the Bunsen absorption coefficient for H2 in the physiological saline is 0.015 at 298 K, and 0.015 mL of H2 can be dissolved in 1 mL of solution under 1 atm (1.01325 bar) of H2 partial pressure [12]. The low concentration and solubility of H2 result in uncertainty regarding its physiological functions. Nevertheless, increasing evidence suggests that H2 may influence biological processes by modulating the oxidation–reduction (redox) environment. The redox environment is defined as an interconnected network of redox couples found in biological fluids, organelles, cells, and throughout the human body overall [13]. Against this background, this review summarizes recent findings on the basic physiological mechanisms of H2, with particular emphasis on its potential role in the redox environment.
2. Endogenous H2 Absorption, Diffusion, and Excretion
The intestines have unique anatomical features that facilitate anaerobic conditions and gut microbiome colonization from birth [14]. Intestinal gas profiles vary among individuals and with their diets. Flatus volumes ranged from 33 to 125 mL, and the mean production rate was 40.25 mL/h [15]. The primary constituents of intestinal gas are nitrogen (N2), oxygen (O2), CO2, H2, and methane. The concentration of N2 was 65.1 ± 20.89%, and that of H2 was 2.9 ± 0.7% in the meta-analysis. Both N2 and H2 are inert gases that do not react with other substances in the human body. Furthermore, H2 accumulation of <76 mL/6 h in the colon gets absorbed [16]. Although H2 solubility is low in the blood, H2 diffuses from the intestinal space to the blood and from the blood to the alveolar air along its partial-pressure gradient [17]. Therefore, the concentration of H2 decreases from the intraintestinal space to the blood and finally to the alveolar space. As an inert gas will distribute itself among the various phases (air, blood, tissues), at equilibrium—according to its respective solubility in each—the solubility of gases in liquids has usually been expressed in two alternative manners. The Bunsen solubility coefficient (α) represents the amount of a particular gas (mL), dissolved at equilibrium in 1 mL of a particular liquid at a specified temperature and a partial pressure of 1 bar (P0). The Bunsen solubility coefficient for H2 in physiological saline is 0.015 mL/mL at 298.15 K. Henry’s law has been shown to apply to the blood solubility of the inert gases. The Bunsen coefficient, therefore, directly yields the amount of gas dissolved by 1 mL of liquid after equilibration at any partial pressure (P) as α × P/P0. If the concentration of H2 in the colon was 2.9%, that in the alveolar gas can be calculated mathematically using the Bunsen solubility coefficient and Henry’s law, which is similar to the mean value of 7 ppm in the healthy fasting H2 concentration, as shown in Figure 1.
[H2 concentration in alveolar air] ≈ 0.029 × 0.015 × 0.015 = 6.5 × 10−6 (6.5 ppm)
Figure 1.
Endogenous H2 absorption, diffusion, and excretion. H2 is a common product of carbohydrate fermentation in the colon and diffuses into the venous blood. Subsequently, venous H2 diffuses into the alveolar air, and alveolar H2 also equilibrates with the arterial blood. Arterial H2 saturates the whole human body due to systemic circulation.
The alveolar air was exhaled through lung ventilation. The breath H2 test measures the end-tidal H2 concentration that is in equilibrium with alveolar air. The diffusion rate of a gas from the gaseous state through a membrane is directly proportional to its solubility and diffusion coefficient in the solvent. The solubility of H2 in water is similar to that of N2, and the diffusion coefficients of H2 and N2 are 5.2 and 2.0 × 10−5 cm2/s, respectively. In such a situation, the diffusion process would take place only within the membrane itself, and if the membrane were sufficiently thin (of the order of 10 μm), a steady state of diffusion would be reached almost instantly. Some mathematical models are used for inert gas transfer across capillary membranes into body tissues in anesthesia and diving medicine [18]. Under atmospheric conditions, the human body becomes saturated with N2. In diving medicine, the human body is classified into five theoretical tissue compartments based on the N2 half-saturation time [19]. The half-saturation time of the colon is approximately 90 min, whereas that of the whole human body is approximately 30 min. Therefore, H2 in the alveolar air saturates the whole human body at the partial pressure of H2 in the alveolar air, 6.5 × 10−6 bar. If the H2 partial pressure in the alveolar air decreases, H2 diffuses from the human body to the alveolar air until a dynamic equilibrium is reached. According to Henry’s law constant of 7.8 × 10−4 (mol/L bar), the concentration of H2 in the human body is calculated as 5.1 × 10−9 (mol/L) under an H2 partial pressure of 6.5 × 10−6 bar [20]. The concentration of H2 in the human body is extremely low, but it is similar to the hydrogen ion concentration in arterial blood at pH 7.4; 10−7.4 = 39 × 10−9 (mol/L).
3. pH and H2 Partial Pressure in the Human Body Affect the Electrochemical Potential
The human body consists of approximately 60% of an aqueous solution that has to be electrically neutral [21]. Accordingly, a membrane potential exists between the interior and exterior of human cells and organelles, as illustrated in Figure 2.
Figure 2.
Membrane potential between the intracellular and extracellular fluids. The unequal distribution of ions across the membrane creates the resting potential. Na+, sodium ion; K+, potassium ion.
The unequal distribution of ions across the membrane creates a resting potential of approximately 70 mV [22]. An action potential occurs as a result of the opening and closing of ion channels on the cell membrane [23]. In the mitochondria, the pH difference between the mitochondrial matrix and the intermembrane space is approximately 0.4 units, which corresponds to roughly a 2.5-fold difference in hydrogen ion activity [24]. Further, the mitochondrial membrane potential is generally around −180 mV, which is equivalent to a 1000-fold difference in hydrogen ion activity. However, the single-electrode potential can only be assessed relative to that of another electrode (i.e., a reference electrode). Therefore, changes in the electrochemical potential were calculated using the potential difference relative to the reference electrode.
The electrochemical potential was measured relative to the standard hydrogen electrode (SHE), which is defined as 0.00 V using a platinum electrode in an acidic solution (pH 0) under an H2 partial pressure of 1 bar H2 [25]. The pH level was measured using the electrochemical potential difference between the sample solution and the standard pH solution with a glass electrode [26]. The primary pH standard solution of the Harned cell was corrected for the H2 partial pressure according to IUPAC recommendations [27]. In the human body, neither H2 nor H+ is a unit; therefore, the reversible hydrogen electrode (RHE) is used as a reference electrode at 37 °C (310 K) [28]:
ERHE = −0.059 × pH − 0.029 × log(H2 partial pressure/1 bar) (V)
Under atmospheric conditions, the concentration of H2, C(H2), can be easily converted to the ratio of the H2 partial pressure to 1 bar. pH2 is defined as the negative logarithm of the H2 fugacity [29].
pH2 = −log[H2 partial pressure/1 bar] = −log[C(H2)]
Under physiological conditions, acid–base homeostasis is maintained in the human body. When 100 ppm H2 gas was bubbled into the phosphate buffer solution, the pH shifted significantly from 7.08 to 7.18 due to the action of the buffer, and the ORP decreased by 56 mV [30]. Based on the Henderson–Hasselbalch equation,
pH = pKa + log10([A−]/[HA])
A change in the pH of 0.1 suggests that the [HPO42−]/[H2PO4−] ratio of the 10 mM phosphate buffer changes by a factor of 10−0.1 (approximately 0.794). Although the potential in the phosphate buffer changed according to the Nernst equation, this suggests that the redox state in vivo is also buffered in addition to the pH; however, the ratio of redox couples within the body can change.
Changes in the electrochemical potential of the human body can be calculated using the RHE, especially pH2. Although H2 partial pressure is extremely low in the human body, the average H2 concentration is already 15-fold higher than that in the atmosphere (7.5 ppm/0.5 ppm), which is 1.18 units in pH2 and approximately 34 mV in RHE potential. As the hydrogen ion concentration is extremely low in neutral fluids, pH 7 = 1 × 10−7 (mol/L), the pH can sensitively indicate acid–base balance. For instance, the pH of the mitochondrial matrix is 7.4, and that in the intermembrane space is 7.8, reflecting the difference in hydrogen ion concentration [31].
Δ[H+] = 10−7.4 − 10−7.8 = 2.3 × 10−8 mol/L
Meanwhile, high concentration of redox couples occurs in the cytoplasm and the mitochondria, for instance, 10 mM glutathione disulfide/glutathione in the cytoplasm and 250 μM nicotinamide adenine dinucleotide (NAD+)/nicotinamide adenine dinucleotide, reduced form (NADH) in the mitochondrial matrix [32,33]. The electrochemical potentials of these redox couples and redox enzymes are measured relative to the reference electrode. When an RHE is used as the reference electrode, the determination of the potential constitutes an electrochemical potential measurement. Therefore, just as with the primary standard pH solution, it is considered necessary to apply corrections based on the H2 partial pressure when measuring electrochemical potentials in vivo. Moreover, proton-coupled electron transfer (PCET) reactions are essential for respiration, and the PCET rate depends on the redox species, temperature, pH, and overpotential during electrochemical processes involving redox cofactors [34]. The blood flow was monitored after free tissue transfer by means of an H2 clearance technique, wherein the generated current was recorded with a platinum electrode after H2 inhalation [35]. When a platinized platinum electrode is polarized at the potential of the standard calomel electrode, the current generated is proportional to the concentration of dissolved H2. The effects of physiological variations in oxygen tension, pH, temperature, and ascorbic acid concentration were found to be negligible [36]. Although absolute calibration in vivo is not possible, the rate of tissue H2 saturation or desaturation can be measured from changes in current using needle-shaped electrodes inserted into the tissue.
4. Redox Enzymes’ Potentials and Their Reaction Rates
The electron transport chain (ETC) in the inner mitochondrial membrane comprises a series of protein complexes that transport electrons from NADH to O2 and drive the generation of adenosine triphosphate (ATP). Each complex contains redox cofactors, such as a metal complex (iron–sulfur clusters or a Cu complex) or an organic molecule (flavin and quinone). Redox cofactors within the enzymes exhibit different thermodynamics and kinetics in the ETC and have different electrochemical potentials distributed over the potential window of water, from −320 mV for NAD+/NADH to +820 mV for O2/H2O, relative to the standard hydrogen electrode (Figure 3) [37]. As the catalytic cofactor is deeply buried in the protein structure of the enzymes, the electrochemical potentials of these enzymes relative to the SHE do not change during natural electron transfer.
where Ecofactor is the in situ potential of the redox cofactor, and E0cofactor is its standard potential relative to the SHE. If the H2 partial pressure is changed, the electrochemical potential of each complex changes relative to the RHE used as the reference electrode.
Ecofactor = E0cofactor − ERHE,
Figure 3.
Redox ladder displays the sequence of reactions in the electron transport chain. These redox gradients are reflected in the ratio of oxidized/reduced redox couples and the redox potentials of complexes. The redox potential of redox cofactors in the complexes is consistent relative to the standard hydrogen electrode (SHE), but those potentials vary for the reversible hydrogen electrode (RHE). FMN; flavin mononucleotide, FeS; iron-sulfur clusters, CoQH2; ubiquinol, Cyt; cytochrome.
In electrochemistry, the immobilization of redox enzymes on an electrode is an analytical tool for investigating electron-transfer reaction rates [38]. When the enzyme substrate is present, the electrode specifically detects electrons released from the substrate. Subsequently, the current is recorded at each applied potential using cyclic voltammetry. The resulting curve was quasi-sigmoidal, and the limiting plateau current was proportional to the catalytic rate constant Kcat of the enzyme. The rate constants (Kcat) for oxidation and reduction are given by the Butler–Volmer equation [39].
where E0RDS is the redox potential of the rate-determining step, while k0 is the standard rate constant and α is the transfer coefficient for the rate-determining step. In a biosensor electrode held at a certain potential, the catalytic current should be proportional to the analyte concentration, such as glucose, in the range where the enzyme is not saturated, as indicated by Michaelis–Menten kinetics [40].
Kox = k0exp[(1 − α)F(E − E0RDS)/RT] and Kred = k0exp[−αF(E − E0RDS)/RT],
current ∝ Kcat × [substrate]
The rate at which electrons pass through the respiratory chain in mitochondria is described by three steps: electron donation (D), electron transfer (T), and electron acceptance (A) [41]. The process is too complex to describe directly using electron transfer theory [42]. Instead, the flux capacity for the overall reaction is the capacity for step T, which can be written as follows [43]:
where c1 is the reduced form of electron carrier 1 and c2+ is the oxidized form of electron carrier 2. The primary determinant of ETC function is the adenosine diphosphate (ADP) concentration, reflecting ATP consumption (energy requirements) [44]. Another way to regulate the ETC is through the concentrations of NADH and succinate, the reducing equivalents [45]. Here, k+ is the rate coefficient for step T, and ET represents the redox complex that catalyzes the step. Although it is impossible to apply an electrochemical potential to the human body, changes in the potential of the RHE can be measured using breath H2 as a reference variable. Despite the complexity of redox reactions within the ETC, its catalytic constant can be evaluated using the breath H2 concentration as an external variable, as illustrated in Figure 4.
v0 = k+[ET][c1][c2+]
Figure 4.
Variables influencing the catalytic kinetics of the electron transport chain (ETC). The catalytic constant of the ETC could be monitored using breath H2 as an external variable, regardless of the difficulty in controlling the other variables; ADP, NADH and O2.
5. H2 Partial Pressure Affects Redox Reactions and Metabolic Reactions
H2 is an inert gas that does not react with biological substrates, even under hyperbaric conditions. During the HYDRA 10 experimental human dive (71 atm/7200 kPa), H2 was introduced during compression on days 4–33 and ultimately reached a partial pressure of 20 atm [46]. The electrocardiogram indicated a marked global decrease in voltage during decompression, which caused the formation of microbubbles as a physical barrier between the heart and the electrode. In 2007, Ohsawa was the first to report the physiological effects of scavenging hydroxyl radicals using 2% H2 gas to treat cerebral ischemia–reperfusion injury in rats. However, the rate constant for the reaction between the hydroxyl radical and H2 is lower than that of most radical-radical reactions, and the targets of hydroxyl radicals are abundant membrane lipids and thiols [47]. The therapeutic window was evaluated prior to reperfusion. Thereafter, many studies demonstrated the protective and therapeutic effects of H2 [48]. Positive indications for H2 therapy have been found in major disease areas among the 81 identified clinical trials and 64 scientific publications involving human studies [49]. Further research is needed to elucidate the mechanisms mediating the physiological effects of H2, particularly its role in modulating redox and metabolic reactions.
The pH of a solution affects the rates of electrochemical processes such as H2 oxidation, O2 reduction, and C reduction [50]. However, the mechanisms that underlie the effects of pH on electrochemical reactions are explained in terms of mass transport, electrochemical double-layer structure, and surface adsorption. In certain redox enzymes, a 2-fold change in pH leads to a 10-fold change in the electron transfer rate constants, according to the outer spherical electron transfer theory [51]. After inhalation of H2 gas, the generated current can be measured using needle-shaped electrodes inserted into the tissue. The current obtained in the absence of H2 (residual current) was generally positive and smaller than the negative current resulting from 3% H2 saturation in vivo. In the phosphate buffer solution, bubbling with 100 ppm H2 caused the redox potential to decrease by approximately 60 mV, compared with the bubbling with air. If the RHE potential decreased due to an increase in pH or H2 partial pressure, the electrochemical potential of the redox couples and redox enzymes would change according to the potential of the RHE as the reference electrode in Figure 5. Although the potential difference between the redox couples and the Gibbs energy remain stable in the redox reaction, the direction of the redox reaction might change from reduction to oxidation, and the oxidation rate constant of the redox enzyme might increase in proportion to a decrease in the RHE potential due to an increase in H2 partial pressure.
Figure 5.
Electrochemical potential changes related to the reference electrode. (a) The electrochemical potential relative to the standard hydrogen electrode (SHE) at pH = 0 and pH2 = 0. The electrochemical potential of CoQ/CoQH2 is +0.03 V. (b) The electrochemical potential relative to the reversible hydrogen electrode (RHE) at pH = 7 and pH2 = 0. The electrochemical potential of CoQ/CoQH2 is +0.45 V. (c) The electrochemical potential relative to the RHE at pH = 7 and pH2 = 6. The electrochemical potential of CoQ/CoQH2 is +0.27 V.
When H2 was added to isolated mitochondria, electron transport driven by succinate was reversed from NAD+ reduction to NADH oxidation, and reactive oxygen species generation was suppressed [52]. In a rat model, long-term H2 inhalation reduced body weight and visceral fat mass [53]. Inhalation of H2 using a nasal cannula (300 mL/min) significantly increased resting fat oxidation, as evidenced by a decreased respiratory exchange ratio, particularly in individuals with higher body fat percentages [54]. The breath acetone concentration has been shown to correlate with the rate of fat loss in healthy individuals as well as with ketosis in diabetic subjects [55]. Inhalation of 1% H2 during exercise-augmented breath acetone and enhanced O2 uptake, compared with the control gas, without affecting oxidative stress or antioxidant activity in human participants [56].
6. Clinical Significance of Breath H2
Human breath is a complex mixture of volatile organic compounds and inorganic gas species that can be used for the noninvasive diagnosis of common diseases [57]. The breath H2 test can be used as a biomarker for diagnosis, including in the context of oxidative stress, gastrointestinal disease, and metabolic disorders [58]. Breath H2 reflects carbohydrate fermentation by the gut microbiota and follows a circadian pattern associated with dietary fiber intake [59]. It is performed by a broad range of healthcare professionals using various methodologies; however, the interpretation of the results remains inconsistent between centers. This has led to some controversy about the use and interpretation of breath testing. The publication of the North American consensus statement is based on the best available evidence to standardize breath H2 methods and, to an extent, their interpretation [60]. The potential of breath H2 as a biomarker has also been reported for conditions other than gastrointestinal diseases. Although breath H2 levels did not differ among the groups before sleep, breath H2 levels in the morning decreased in patients with chronic heart failure (CHF) than in those without CHF [61], and in older subjects (60−85 years) than in younger subjects (20−59 years) [62]. In particular, changes in breath H2 concentrations are being investigated in relation to exercise and metabolism. Following exercise, breath H2 levels declined at 5 min, approached baseline at 30 min, and declined again at 60 min [63]. The breath H2 concentration was consistently and positively associated with an integrated cellular bioenergetic phenotype derived from body cell mass, intracellular water, total body potassium, and glycogen [64]. However, H2 is not metabolized in the human body (the internal environment) but is a common product of carbohydrate fermentation by the human gut microbiota (the external environment). As a small fraction of H2 in venous blood will always pass through the lungs without being cleared, arterial blood and tissues are saturated with alveolar H2, which is measured by the breath H2 test. Additionally, breath H2 can be an external variable of the redox environment, which is associated with redox enzyme function and energy metabolism (Figure 6). The limitation of the breath H2 test is that there is no consensus on a normal value with respect to age, sex, daily excretion patterns, dietary effects, and exercise, as well as on the interpretation of the results. The measurement of breath H2 is mainly used clinically and reviewed by healthcare professionals and clinical researchers. Standardized breath sampling methods and low-cost, easy-to-use, rapid, portable devices are urgently required.
Figure 6.
Conceptual framework illustrating breath H2 as a measurable or controllable external variable in the systemic redox environment. Changes in breath H2 may influence the catalytic kinetics of redox reactions in the human body and may be used to evaluate electrochemical current–potential characteristics through physiological responses, such as the respiratory exchange ratio and markers of oxidative stress.
7. Conclusions
Metabolic reactions in the human body involve quasi-reversible and irreversible multistep processes. When electron transfer continues, the rate-determining step is an electron-transfer step in the ETC, and its kinetics influence the electrochemical response. Thus, current–potential characteristics should be evaluated in terms of controllable parameters such as the concentrations of the participating species. Notably, H2 is not produced or metabolized in human cells, but a common product of carbohydrate fermentation by the gut microbiota is distributed throughout the human body. H2 is a reductant that influences the electrochemical potential of redox enzymes, including those in the ETC. Therefore, breath H2 may represent an external variable of the redox environment in the human body. Future studies should focus on verifying redox metabolic kinetics using measurable and controllable breath H2 for the clinical diagnosis and treatment of diseases.
Funding
This research received no external funding.
Institutional Review Board Statement
Not applicable.
Informed Consent Statement
Not applicable.
Data Availability Statement
No new data were created or analyzed in this study. Data sharing is not applicable to this article.
Conflicts of Interest
The author declares no conflicts of interest.
Abbreviations
The following abbreviations are used in this manuscript:
| H2 | Molecular hydrogen |
| N2 | Nitrogen |
| O2 | Oxygen |
| pH | Hydrogen ion activity |
| SHE | Standard hydrogen electrode |
| RHE | Reversible hydrogen electrode |
| ERHE | Potential of the reversible hydrogen electrode |
| ppb | Parts per billion |
| ppm | Parts per million |
| C(H2) | The concentration of hydrogen |
| PCET | Proton-coupled electron transfer |
| ETC | Electron transport chain |
| ATP | Adenosine triphosphate |
| ADP | Adenosine diphosphate |
| NAD+ | Nicotinamide adenine dinucleotide |
| NADH | Nicotinamide adenine dinucleotide, reduced form |
| Kcat | Catalytic rate constant |
| k0 | Standard rate constant |
| E0RDS | Redox potential of the rate determining step |
| CHF | Chronic heart failure |
References
- Patterson, J.D.; Aydin, M.; Crotwell, A.M.; Petron, G.; Severinghaus, J.P.; Saltzman, E.S. Atmospheric history of H2 over the past century reconstructed from South Pole firn air. Geophys. Res. Lett. 2020, 47, e2020GL087787. [Google Scholar] [CrossRef] [Scilit]
- Rezaei, S.; Hormaza, M.A.; Wu, Y.; Reed, J.; Brouwer, J. Global warming impacts of the transition from fossil fuel conversion and infrastructure to hydrogen. Appl. Energy 2025, 397, 126363. [Google Scholar] [CrossRef] [Scilit]
- Sandhiya, L.; Bhati, M. Unravelling the atmospheric and climate implications of hydrogen leakage. Int. J. Hydrogen Energy 2023, 53, 807–815. [Google Scholar] [CrossRef] [Scilit]
- Tong, M.-N.; Li, X.; Cheng, J.; Jiang, Z.-L. Developments in the Study of Inert Gas Biological Effects and the Underlying Molecular Mechanisms. Int. J. Mol. Sci. 2025, 26, 7551. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Ketty, S.S. The theory and applications of the exchange of inert gas at the lungs and tissues. Pharmacol. Rev. 1951, 3, 1–41. [Google Scholar] [CrossRef] [Scilit]
- Ohsawa, I.; Ishikawa, M.; Takahashi, K.; Watanabe, M.; Nishimaki, K.; Yamagata, K.; Katsura, K.; Katayama, Y.; Asoh, S.; Ohta, S. Hydrogen acts as a therapeutic antioxidant by selectively reducing cytotoxic oxygen radicals. Nat. Med. 2007, 13, 688–694. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Christensen, H.; Sehested, K. Reaction of hydroxyl radicals with hydrogen at elevated temperatures. Determination of the activation energy. J. Phys. Chem. 1983, 87, 118–120. [Google Scholar] [CrossRef] [Scilit]
- Perman, J.A.; Modler, S.; Barr, R.G.; Rosenthal, P. Fasting breath hydrogen concentration: Normal values and clinical application. Gastroenterology 1984, 87, 1358–1363. [Google Scholar] [CrossRef] [Scilit]
- Farhi, L.E. Elimination of inert gas by the lung. Respir. Physiol. 1967, 3, 1–11. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Hall, J.E. Physical principles of gas exchange. In Guyton and Hall Textbook of Medical Physiology, 12th ed.; WB Saunders: Philadelphia, PA, USA, 2015; pp. 485–494. [Google Scholar]
- Yamamoto, R.; Homma, K.; Suzuki, S.; Sano, M.; Sasaki, J. Hydrogen gas distribution in organs after inhalation: Real-time monitoring of tissue hydrogen concentration in rat. Sci. Rep. 2019, 9, 1255. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Raposo, R.R.; Calviño, E.F.; Esteso, M.A. Determination of Hydrogen Solubility Values in Some Human Fluids by Using an Electrochemical Sensor. ETS Trans. 2007, 3, 127. [Google Scholar] [CrossRef] [Scilit]
- Schafer, F.Q.; Buettner, G.R. Redox environment of the cell as viewed through the redox state of the glutathione disulfide/glutathione couple. Free Radic. Biol. Med. 2001, 30, 1191–1212. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Yang, K.; Li, G.; Li, Q.; Wang, W.; Zhao, X.; Shao, N.; Qiu, H.; Liu, J.; Xu, L.; Zhao, J. Distribution of gut microbiota across intestinal segments and their impact on human physiological and pathological processes. Cell Biosci. 2025, 15, 47. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Modesto, A.; Cameron, N.R.; Varghese, C.; Peters, N.; Stokes, B.; Phillips, A.; Bissett, I.; O’Grady, G. Meta-Analysis of the Composition of Human Intestinal Gases. Dig. Dis. Sci. 2022, 67, 3842–3859. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Hammer, H.F. Colonic hydrogen absorption: Quantification of its effect on hydrogen accumulation caused by bacterial fermentation of carbohydrates. Gut 1993, 34, 818–822. [Google Scholar] [CrossRef] [Scilit] [PubMed] [PubMed Central]
- Azpiroz, F. Intestinal gas dynamics: Mechanisms and clinical relevance. Gut 2005, 54, 893–895. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Baker, A.B.; Farmery, A.D. Inert gas transport in blood and tissues. Compr. Physiol. 2011, 1, 569–592. [Google Scholar] [CrossRef] [Scilit]
- Kot, J.; Sicko, Z.; Doboszynski, T. The Extended Oxygen Window Concept for Programming Saturation Decompressions Using Air and Nitrox. PLoS ONE 2015, 25, e0130835. [Google Scholar]
- Sander, R. Compilation of Henry’s law constants (version 5.0.0) for water as solvent. Atmos. Chem. Phys. 2023, 23, 10901–12440. [Google Scholar] [CrossRef] [Scilit]
- Delpire, E.; Gagnon, K.B. Water Homeostasis and Cell Volume Maintenance and Regulation. Curr. Top. Membr. 2018, 81, 3–52. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Chrysafides, S.M.; Bordes, S.J.; Sharma, S. Physiology, Resting Potential. In StatPearls; StatPearls Publishing LLC.: Treasure Island, FL, USA, 2023. Available online: https://www.ncbi.nlm.nih.gov/books/NBK538338/ (accessed on 20 July 2026).
- Clay, J.R. Determining k channel activation curves from k channel currents often requires the goldman-hodgkin-katz equation. Front. Cell Neurosci. 2009, 3, 20. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Ahmed Selim, N.; Wojtovich, A.P. Mitochondrial membrane potential and compartmentalized signaling: Calcium, ROS, and beyond. Redox Biol. 2025, 86, 103859. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Jerkiewicz, G. Standard and Reversible Hydrogen Electrodes: Theory, Design, Operation, and Applications. ACS Catal. 2020, 10, 8409–8417. [Google Scholar] [CrossRef] [Scilit]
- Bates, R.G.; Vijh, A.K. Determination of pH: Theory and Practice. J. Electrochem. Soc. 1973, 120, 263c. [Google Scholar] [CrossRef] [Scilit]
- Buck, R.P.; Rondinini, S.; Covington, A.; Baucke, F.; Brett, C.; Camoes, M.; Milton, M.; Mussini, T.; Naumann, R.; Pratt, K.; et al. Measurement of pH definition, standards, and procedures. Pure Appl. Chem. 2002, 74, 2169–2200. [Google Scholar] [CrossRef] [Scilit]
- Kiyama, T. Environmental Hydrogen Concentration as a Novel Factor Determining Changes in Redox Potential. Physiologia 2025, 5, 36. [Google Scholar] [CrossRef] [Scilit]
- Kiyama, T. Hydrogen Electrode Potentials as a Descriptor of Catalyst Reactivity for Sustainable Redox Chemistry: A Tutorial Review. Sustainability 2026, 18, 5791. [Google Scholar] [CrossRef] [Scilit]
- Kiyama, T.; Tokunaga, A.; Naji, A.; Barbul, A. Changes in the negative logarithm of end-tidal hydrogen partial pressure indicate the variation of electrode potential in healthy Japanese subjects. Sci. Rep. 2023, 13, 15473. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Porcelli, A.M.; Ghelli, A.M.; Zanna, C.; Pinton, P.; Rizzuto, R.; Rugolo, M. pH difference across the outer mitochondrial membrane measured with a green fluorescent protein mutant. Biochem. Biophys. Res. Comm. 2005, 326, 799–804. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Milo, R.; Phillips, R. What is the redox potential of a cell? In Cell Biology by the Numbers, 1st ed.; Garland Science: New York, NY, USA, 2015; pp. 189–196. [Google Scholar]
- Cantó, C.; Menzies, K.; Auwerx, J. NAD+ Metabolism and the Control of Energy Homeostasis: A Balancing Act between Mitochondria and the Nucleus. Cell Metab. 2015, 22, 31–53. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Hammes-Schiffer, S. Theory of proton-coupled electron transfer in energy conversion processes. Acc. Chem. Res. 2009, 42, 1881–1889. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Machens, H.G.; Mailaender, P.; Reimer, R.; Pallua, N.; Lei, Y.; Berger, A. Postoperative blood flow monitoring after free-tissue transfer by means of the hydrogen clearance technique. Plast. Reconstr. Surg. 1997, 99, 493–505. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Aukland, K.; Bower, B.F.; Berliner, R.W. Measurement of local blood flow with hydrogen gas. Circ. Res. 1964, 14, 164–187. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Bollella, P.; Katz, E. Enzyme-Based Biosensors: Tackling Electron Transfer Issues. Sensors 2020, 20, 3517. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Kano, K. Fundamental insight into redox enzyme-based bioelectrocatalysis. Biosci. Biotechnol. Biochem. 2022, 86, 141–156. [Google Scholar] [CrossRef] [Scilit]
- Bard, A.J.; Faulkner, L.R. Electrochemical Methods: Fundamentals and Applications, 2nd ed.; John Wiley & Sons: New York, NY, USA, 2000. [Google Scholar]
- Zhang, X.; Xin, J.; Jin, R. Electrochemical glucose sensing using an electrochemically reduced graphene oxide/poly-L-lysine composite electrode modified with glucose oxidase. Int. J. Electrochem. Sci. 2026, 21, 101357. [Google Scholar] [CrossRef] [Scilit]
- Jin, Q.; Bethke, C. Kinetics of Electron Transfer through the Respiratory Chain. Biophys. J. 2002, 83, 1797–1808. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Davidson, V.L. Unraveling the kinetic complexity of interprotein electron transfer reactions. Biochem. 1996, 35, 14035–14039. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Pring, M. The analysis of electron transport kinetics in mitochondria. In Concepts and Models of Biomathematics: Simulation Techniques and Methods; Heinmetz, F., Ed.; Dekker: New York, NY, USA, 1969; pp. 75–104. [Google Scholar]
- Meyrat, A.; von Ballmoos, C. ATP synthesis at physiological nucleotide concentrations. Sci. Rep. 2019, 9, 3070. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Vercellino, I.; Sazanov, L.A. The assembly, regulation and function of the mitochondrial respiratory chain. Nat. Rev. Mol. Cell Biol. 2022, 23, 141–161. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Lafay, V.; Barthelemy, P.; Comet, B.; Frances, Y.; Jammes, Y. ECG changes during the experimental human dive HYDRA 10 (71 atm/7,200 kPa). Undersea Hyperb. Med. 1995, 22, 51–60. [Google Scholar] [PubMed]
- Wood, K.; Gladwin, M. The hydrogen highway to reperfusion therapy. Nat. Med. 2007, 13, 673–674. [Google Scholar] [CrossRef] [Scilit]
- Yildiz, F.; LeBaron, T.W.; Alwazeer, D. A comprehensive review of molecular hydrogen as a novel nutrition therapy in relieving oxidative stress and diseases: Mechanisms and perspectives. Biochem. Biophys. Rep. 2025, 41, 101933. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Johnsen, H.M.; Hiorth, M.; Klaveness, J. Molecular Hydrogen Therapy—A Review on Clinical Studies and Outcomes. Molecules 2023, 28, 7785. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Govindarajan, N.; Xu, A.; Chan, K. How pH affects electrochemical processes. Science 2022, 375, 379–380. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Kulys, J.; ČèNas, N. Reagent redox potential and pH effects on the enzymatic electron transfer. J. Mol. Catal. 1988, 47, 335–341. [Google Scholar] [CrossRef] [Scilit]
- Ishihara, G.; Kawamoto, K.; Komori, N.; Ishibashi, T. Molecular hydrogen suppresses superoxide generation in the mitochondrial complex I and reduced mitochondrial membrane potential. Biochem. Biophys. Res. Commun. 2019, 522, 965–970. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Adzavon, Y.M.; Xie, F.; Yi, Y.; Jiang, X.; Zhang, X.; He, J.; Zhao, P.; Liu, M.; Ma, S.; Ma, X. Long-term and daily use of molecular hydrogen induces reprogramming of liver metabolism in rats by modulating NADP/NADPH redox pathways. Sci. Rep. 2022, 12, 3904. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Botek, M.; McKune, A.; Grepl, P.; Krejčí, J. Molecular hydrogen inhalation modulates resting metabolism in healthy females: Findings from a randomized, double-blind, placebo-controlled crossover study. Med. Gas. Res. 2025, 15, 367–373. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Anderson, J.C. Measuring breath acetone for monitoring fat loss: Review. Obesity 2015, 23, 2327–2334. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Hori, A.; Ichihara, M.; Kimura, H.; Ogata, H.; Kondo, T.; Hotta, N. Inhalation of molecular hydrogen increases breath acetone excretion during submaximal exercise: A randomized, single-blinded, placebo-controlled study. Med. Gas. Res. 2020, 10, 96–102. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Alenzy, E.; Kandjani, A.E.; Shaibani, M.; Trinchi, A.; Bhargava, S.K.; Ippolito, S.J.; Sabri, Y.M. Human breath analysis; Clinical application and measurement: An overview. Biosens. Bioelectron. 2024, 278, 117094. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Shin, W. Medical applications of breath hydrogen measurements. Anal. Bioanal. Chem. 2014, 406, 3931–3939. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Kagaya, M.; Iwata, M.; Toda, Y.; Nakae, Y.; Kondo, T. Circadian rhythm of breath hydrogen in young women. J. Gastroenterol. 1998, 33, 472–476. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Rezaie, A.; Buresi, M.; Lembo, A.; Lin, H.; McCallum, R.; Rao, S.; Schmulson, M.; Valdovinos, M.; Zakko, S.; Pimentel, M. Hydrogen and Methane-Based Breath Testing in Gastrointestinal Disorders: The North American Consensus. Am. J. Gastroenterol. 2017, 112, 775–784. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Shibata, A.; Sugano, Y.; Shimouchi, A.; Yokokawa, T.; Jinno, N.; Kanzaki, H.; Ohta-Ogo, K.; Ikeda, Y.; Okada, H.; Aiba, T.; et al. Decrease in exhaled hydrogen as marker of congestive heart failure. Open Heart 2018, 5, e000814. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Okumura, N.; Kiriyama, K.; Taniguchi, K. Age differences in overnight breath hydrogen dynamics and their association with sleep physiology. J. Breath. Res. 2026, 20, 036003. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Todorovic, N.; Kuzmanovic, J.; Javorac, D.; Ostojic, S.M. The impact of graded exercise to exhaustion on breath hydrogen: A pilot study. Sport. Sci. Health 2025, 21, 3579–3583. [Google Scholar] [CrossRef] [Scilit]
- Todorovic, N.; Nedeljkovic, D.; Andjelic, B.; Korovljev, D.; Tarnava, A.; Ostojic, S.M. Breath Hydrogen Reflects a Cellular Bioenergetic Phenotype in Sedentary Adults with Metabolic Syndrome. Clin. Bioenerg. 2026, 2, 6. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the author. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.