Skip to Content
CivilEngCivilEng
  • Article
  • Open Access

9 October 2026

19 Pages

Equivalent Cross-Sectional Area of Micropile Groups Under Different Surrounding Rock-Mass Strengths

,
,
,
,
and
1
Faculty of Land Resource Engineering, Kunming University of Science and Technology, Kunming 650093, China
2
Key Laboratory of Prediction and Mitigation of Geological Hazards in Plateau Mountainous Areas, Ministry of Natural Resources, Kunming 650093, China
3
Yunnan Provincial Key Laboratory of Prediction and Mitigation of Geological Hazards in Plateau Mountainous Areas, Kunming 650093, China
*
Author to whom correspondence should be addressed.

Abstract

This study investigated the effects of surrounding-rock strength and pile arrangement on the direct shear capacity of micropile groups. Forty-eight specimens representing three pile arrangements, four mortar grades (M5, M10, M15, and M25), and four replicates per condition were tested, and the 12 corresponding conditions were simulated within a calibrated FLAC3D framework. Peak loads were compared with simulated peak reactions. The output of the proposed “equivalent cross-sectional area” formulation, Aeq,ref, was defined as an assumption-dependent capacity-normalization index with units of area, not a measured geometric or cooperative area. It was calculated from adopted reference values for peak shear stress (τref) and effective height (Lref), neither independently measured. Mean peak load increased with mortar grade, but no pile arrangement was consistently superior. Ten of 12 simulated peaks differed from the experimental means by less than 10%; the circular M5 and M10 errors were 17.74% and 10.48%, respectively. Aeq,ref decreased by approximately 54–61% from M5 to M25 because the adopted τref increased faster than the measured group capacity. Accordingly, the index is valid only within the adopted reference-parameter framework and should not be used for design until interface strength and shear-band thickness are independently determined.

1. Introduction

Small-diameter steel-tube micropile groups are widely used for rapid slope stabilization [1]. Group interaction governs their overall response, so group stiffness and capacity cannot be obtained by simply summing the responses of individual piles. Existing design approaches do not fully capture these interaction effects under horizontal loading, which limits the refined analysis and design of micropile groups.
Early equivalent methods for micropile groups focused primarily on stiffness and ultimate-capacity equivalence. Randolph and Wroth [2] separated pile-shaft axial resistance from pile-base resistance and derived an analytical solution for a vertically loaded single pile in linear-elastic soil. They also represented soil stiffness using an equivalent shear modulus and an influence radius, providing a basis for equivalent-continuum approaches. Poulos and Davis [3] subsequently proposed the Equivalent Pier Method, which represents a pile group as a single pier with an equivalent diameter and stiffness for settlement analysis. These studies established the theoretical basis for equivalent pile-group calculations. Zhao et al. [4] investigated load-transfer-based settlement calculations for pile foundations, whereas Liang et al. [5] developed a micromechanical model for rock-pile interfaces, highlighting the importance of interface response in equivalent analyses.
International studies have also addressed the lateral capacity and dynamic response of micropile groups. Jamaleddin et al. [6] proposed regression equations for lateral capacity and overturning moment in sandy seabeds, together with an M-H envelope framework. Swallow et al. [7] used finite-element analysis to show that group geometry significantly affects the lateral capacity of closely spaced piles and that the number of piles aligned with the loading direction is particularly important. In dynamic studies, Ghassemi et al. [8] found that micropile performance in liquefiable sand depends on input frequency, stiffness, and distribution density, while Ghorbani et al. [9] showed that micropile number, spacing ratio, inclination, soil density, and loading intensity jointly influence liquefaction response. Capatti et al. [10] further observed gap opening and slippage at the soil–micropile interface under large-strain dynamic loading. These findings indicate that static peak resistance should not be interpreted directly as an allowable dynamic state.
Research in China has further advanced equivalent analysis and understanding of micropile-group load-transfer mechanisms. Zhu et al. [11] developed a calculation model for anchor-cable–micropile groups that accounts for elastoplastic deformation of the embedded segment, while Deng et al. [12] used model tests to quantify the influence of pile spacing on group effects. For interface behavior, Liu et al. [13] showed that water content and surface roughness affect the shear response of granite residual soil–concrete interfaces, underscoring the importance of interface conditions. Engineering studies by Ou et al. [14], Wu et al. [15], Ren et al. [16], and Sun et al. [17] further examined combined support, spacing effects, pile-group behavior, and soil arching, respectively.
International field and model studies likewise show that micropile and pile-group responses depend on loading mode, spacing, inclination, and load sharing among group rows. Kershaw and Luna measured full-scale micropile responses under axial, lateral, and combined loading [18]. Kyung and Lee combined model tests with finite-element analysis to investigate inclined single and group micropiles [19]. Rollins et al. quantified row-dependent interaction in a full-scale laterally loaded pile group [20]. Although these studies establish the importance of configuration and ground response, they do not provide an assumption-explicit capacity-normalization relationship for direct shearing in rock-like materials.
In summary, equivalent approaches for vertical loading are relatively mature. However, a transparent method for conditionally normalizing micropile-group capacity under horizontal shearing across different surrounding-rock strengths remains lacking. This study retains the term “equivalent cross-sectional area” as the name of the capacity-equivalence formulation. Throughout the paper, the term denotes a calculated capacity-normalization index with units of area rather than a physically measured cooperative area. Laboratory direct shear tests were used to quantify the peak capacities of three pile arrangements at four surrounding-rock strength levels, and FLAC3D simulations were used to examine load-response trends within an internally calibrated numerical framework. The resulting index was calculated from adopted reference parameters, and its assumptions and limitations were evaluated explicitly.

2. Materials and Methods

Surrounding-rock strength and pile arrangement were selected as the principal factors, while the remaining test parameters were held constant. Laboratory direct shear tests were conducted to determine the peak shear capacity of micropile groups under the specified conditions. The measured loads served as experimental inputs for an assumption-dependent capacity-normalization index defined using adopted reference parameters.

2.1. Specimen Design

The micropile-group composite specimens, including the analogous surrounding-rock material, measured 149 mm × 149 mm × 149 mm. For concrete–rock interface direct shear specimens, GB/T 50266-2013 recommends cubic specimens with side lengths of at least 150 mm [21]. The selected dimension was therefore 1 mm below the recommended value because of the internal dimensions of the available shear box; this deviation is acknowledged as an experimental limitation. Each specimen comprised an external surrounding-rock material, internal micropiles, and central reinforcement. The micropiles consisted of Q235 steel tubes with an outer diameter of 19 mm. Each tube contained an HRB400 reinforcing bar with a radius of 3 mm and was grouted with M25 cement mortar. The specimen components were specified as follows:
(1)
Analogous surrounding rock: M5, M10, M15, and M25 cement mortars represented controlled rock- and soil-like materials with different strengths.
(2)
Steel tube: A circular Q235 steel tube with an outer radius of 9.5 mm was used to promote pile–mortar interaction.
(3)
Grouting material: M25 cement mortar was used to provide pile strength and dense internal filling.
(4)
Reinforcement: A longitudinal HRB400 reinforcing bar with a radius of 3 mm was used to improve tensile and shear resistance.
The rectangular, circular, and quincunx pile arrangements are shown in Figure 1. Four surrounding-rock conditions (M5, M10, M15, and M25) were considered for each arrangement. Four replicate specimens were prepared for each condition, giving a total of 48 specimens.
Figure 1. Rectangular, circular, and quincunx micropile-group arrangements.

2.2. Test Materials and Equipment

The specimens incorporated Q235 steel tubes with an outer diameter of 19 mm, HRB400 reinforcing bars with a diameter of 6 mm, ordinary Portland cement, and medium sand. M5, M10, M15, and M25 cement mortars represented analogous surrounding-rock materials with different strength grades. Loading was applied using an MTSYSD microcomputer-controlled servo rock direct shear apparatus manufactured by Tianjin Meitesi Testing Machine Factory, Tianjin, China. A metal shear box, a JQ350 mixer, and other auxiliary equipment were also used.
The initial mortar mix proportions in Table 1 were selected from the recommended ranges in the Specification for Mix Proportion Design of Masonry Mortar (JGJ/T 98-2010) [22] and then adjusted during trial preparation. The cement content was varied to prepare M5, M10, M15, and M25 analogous surrounding-rock materials. In this study, these grades provide controlled mortar-strength levels and should not be interpreted as direct classifications of natural rock weathering.
Table 1. Consumption of cement mortar per cubic meter (kg/m3).
Based on these proportions, the mold volume was 0.149 × 0.149 × 0.149 = 0.003308 m3. Because direct proportioning at this small volume was impractical, the material quantities were scaled to a reference batch volume of 0.05 m3. The cement and water quantities were calculated using the maximum recommended proportions and are summarized in Table 2.
Table 2. Cement and water consumption data sheet.

2.3. Specimen Preparation and Curing

The specimens were prepared as follows: (1) The mold was assembled and the pile positions were marked. Rust was removed from the steel tubes and reinforcing bars before the components were fixed in the mold. (2) Cement mortar was prepared according to the mix proportions in Table 1. The surrounding-rock portion was cast first and vibrated to remove entrapped air. When casting reached the pile elevation, M25 mortar was injected and the reinforcing bars were inserted. (3) After demolding, the specimens were subjected to standard curing for at least 30 days. Their surfaces were kept moist, and water was sprayed two to three times per day after final setting. Each cured specimen was inspected for surface quality; specimens with visible cracks, defects, or excessive pile-position deviations were rejected. Qualified specimens were then transferred to the laboratory for direct shear testing.

2.4. Direct Shear Test Procedure

Peak shear loads were evaluated using a two-way factorial analysis of variance, with mortar grade and pile arrangement treated as fixed factors and their interaction included. Four independently prepared specimens were tested per condition, and all observations were retained. Effect sizes were reported as partial eta squared (partial η2), and statistical significance was evaluated at α = 0.05.
After curing, laboratory direct shear tests were conducted according to the experimental design. The procedure was as follows:
(1)
Specimen installation: The cured specimen was removed and its surfaces were ground and cleaned to remove debris. The specimen was placed in the lower half of the shear box on the microcomputer-controlled servo rock direct shear apparatus. Its position was adjusted until the predefined shear plane coincided with the interface between the two halves of the shear box, after which the upper half was installed. Alignment was checked again to promote uniform loading and minimize eccentricity.
(2)
Equipment commissioning: The direct-shear apparatus was operated without load, and the loading rate, data-acquisition accuracy, and other settings were checked to confirm normal operation and reliable data collection.
(3)
Loading: Displacement-controlled loading was applied. No normal stress was imposed; only horizontal shear displacement was applied. Tangential load and the associated response data were recorded throughout loading.
(4)
Failure criterion: Horizontal shearing continued until clear failure occurred. Failure was identified by a rapid decrease in load after the peak tangential load, together with the appearance of distinct shear cracks. Loading was then stopped, and the maximum tangential load was recorded.
Each specimen was tested separately according to this procedure. After each test, the equipment and test area were cleaned, and the test records were archived. Figure 2 summarizes specimen preparation and the direct shear test procedure.
Figure 2. Specimen preparation and direct shear test procedure.

3. Results

This section presents the observed failure patterns, direct shear responses, statistical results, numerical simulations, and conditional reference-index calculations.

3.1. Specimen Failure Characteristics

All specimens failed along the predefined shear plane, consistent with the intended test configuration. The visible failure characteristics varied among conditions. Because the program included many specimens, representative specimens exhibiting clearly discernible failure patterns were selected for illustration. Their failure modes are shown in Figure 3, Figure 4 and Figure 5.
Figure 3. Failure modes of rectangular pile groups under different surrounding-rock conditions. The letters and numbers shown on the specimens are specimen identification codes.
Figure 4. Failure modes of circular pile groups under different surrounding-rock conditions. The letters and numbers shown on the specimens are specimen identification codes.
Figure 5. Failure modes of quincunx pile groups under different surrounding-rock conditions. The letters and numbers shown on the specimens are specimen identification codes.
The observed failure patterns changed as surrounding-rock strength increased from M5 to M25. Among the selected representative specimens, damage tended to shift from broad cracking and spalling toward narrower, localized shear bands. Visible damage also varied with arrangement: the rectangular specimen exhibited a broad damaged zone and dislocation, the circular specimen showed less extensive damage and pile inclination, and the selected quincunx specimen retained comparatively good integrity with small local cracks. These qualitative observations apply only to the photographed specimens and do not establish statistically superior capacity or stronger cooperative action for any arrangement.

3.2. Direct Shear Test Results

The microcomputer-controlled electrohydraulic servo direct shear apparatus recorded tangential load–time curves from which peak shear loads were determined. Four replicate specimens were tested for every combination of pile arrangement and M5–M25 surrounding-rock grade. Figure 6, Figure 7 and Figure 8 present the resulting curves and characterize the effects of surrounding-rock strength and pile arrangement on the shear response.
Figure 6. Tangential load–time curves for the rectangular pile group. (a) M5; (b) M10; (c) M15; (d) M25.
Figure 7. Tangential load–time curves for the circular pile group. (a) M5; (b) M10; (c) M15; (d) M25. Note: The time axis in subfigure (a) for M5 spans 0–400 s, whereas those in the other subfigures span 0–120 s. The wider range shows the complete response of the M5 specimens. The vertical magenta line at 120 s marks the termination time used for the other test groups and facilitates direct comparison.
Figure 8. Tangential load–time curves for the quincunx pile group. (a) M5; (b) M10; (c) M15; (d) M25.
Figure 6, Figure 7 and Figure 8 show the direct shear responses. The loading and data-reduction procedures followed the general direct shear principles in the Standard for Geotechnical Testing method (GB/T 50123-2019) [23]. Because the composite specimens and loading configuration differed from standard soil direct shear specimens, the tests are not presented as fully compliant standard tests. The response was interpreted in four stages:
(1)
Compaction stage. After the initial shear force was applied, small internal voids were progressively compacted. Deformation increased rapidly, whereas the shear force increased only slightly or exhibited a brief plateau.
(2)
Elastic deformation stage. After compaction, relative displacement developed along the shear plane. Load and displacement were approximately linearly related, the material response remained predominantly elastic, and internal microcracking was limited.
(3)
Plastic deformation stage. With increasing shear displacement, macroscopic cracks or plastic zones developed. Sliding and dislocation occurred on both sides of the shear plane, and the rate of shear-force increase declined.
(4)
Failure stage. Once the shear force reached its maximum, continued loading caused material failure. The load decreased rapidly in brittle specimens, whereas specimens exhibiting greater plastic deformation retained a lower residual-strength plateau.
For each specimen, the peak shear load was taken as the maximum tangential load recorded at shear failure. Table 3 presents the measured peak loads for the three pile arrangements.
Table 3. Peak shear loads for the three pile arrangements.
Table 3 combines the four replicate peak shear loads for the rectangular, circular, and quincunx arrangements. Table 4 reports the mean, sample standard deviation (SD), coefficient of variation (CV), and two-sided 95% confidence interval for each condition. All observations were retained; none was excluded as an outlier.
Table 4. Descriptive statistics for peak shear load.
Table 4 shows that the mean peak shear load increased from M5 to M25 for all three arrangements. The circular arrangement had the highest mean at M5 and M10, whereas the rectangular arrangement had the highest mean at M15 and M25. However, the differences among arrangement means were small relative to the within-condition variability, particularly at M5. The rectangular M5 condition had an SD of 23.45 kN, a CV of 43.8%, and a 95% confidence interval of 16.24–90.88 kN. The quincunx M5 and M10 conditions also exhibited notable scatter, with CVs of 21.0% and 12.8%, respectively. Thus, the data support an increase in capacity with surrounding-rock strength but do not support a statistically reliable ranking of pile arrangements.
A two-way factorial analysis indicated a significant main effect of mortar grade on peak shear load, F(3, 36) = 122.39, p < 0.001, partial η2 = 0.911. In contrast, neither the main effect of pile arrangement, F(2, 36) = 0.70, p = 0.502, partial η2 = 0.038, nor the mortar-grade × arrangement interaction, F(6, 36) = 0.57, p = 0.750, partial η2 = 0.087, was statistically significant.

3.3. Experimental Trends

For all three arrangements, the mean peak shear load increased as the mortar grade rose from M5 to M25. This trend is consistent with greater resistance from the stronger surrounding material and along the pile–rock interface. Because interface stresses were not measured directly, the tests establish the overall capacity trend but do not independently quantify load partitioning between the piles and surrounding rock.
The circular arrangement produced the highest mean peak load at M5 and M10, whereas the rectangular arrangement produced the highest mean at M15 and M25. The absolute differences among arrangement means were small, and the corresponding confidence intervals overlapped. Although the selected quincunx specimens exhibited comparatively limited visible damage, this qualitative observation does not demonstrate greater peak capacity. The four-replicate dataset therefore supports only the description of arrangement-dependent tendencies, not the identification of a generally superior arrangement.

3.4. Numerical Model Development

To complement the experimental results and examine load-transfer trends, a three-dimensional FLAC3D (Version 6.0) model measuring 149 mm × 149 mm × 149 mm was developed. Continuum zones governed by the Mohr–Coulomb model represented the surrounding rock and grouting mortar. Shell elements represented the steel tubes, and pile structural elements represented the reinforcing bars; both steel components were treated as linear elastic. Coupling springs represented pile–rock interaction. The boundary conditions reproduced the experimental configuration: the bottom was fixed, the sides were partially constrained, and the top was free. A horizontal displacement increment of 0.5 × 10−6 m/step was applied to the upper portion of the x = 0 face. The total reaction-force history was monitored and compared with the experimental results for internal calibration. After calibration, the simulated peak reactions provided a model-derived input for calculating the conditional reference index. Figure 9 shows the model geometry and boundary conditions.
Figure 9. FLAC3D model geometry and boundary conditions. The numerical labels indicate the model dimensions in mm.
The model boundary constraints approximated the restraining effect of the shear box without explicitly modeling box-specimen contact. This simplification allowed the total reaction associated with the modeled pile–rock system to be extracted directly. A FISH function monitored the total reaction force, which was compared with the experimental tangential load–time curves. Calibration proceeded by sequentially adjusting the elastic modulus, cohesion, internal friction angle, and other strength parameters of the surrounding material. Each condition was simulated, and its peak tangential reaction force was extracted to characterize the variation in micropile-group capacity with surrounding-rock strength.
The surrounding-rock parameters were calibrated iteratively using theoretical preselection and experimental feedback. Laboratory peak shear forces and observed failure patterns served as calibration targets. GB 50003-2011, JGJ/T 70-2009, and GB/T 50218-2014 [24,25,26] provided contextual guidance on mortar-grade terminology, basic mortar-property testing, and rock-mass classification; they were not direct sources of the calibrated FLAC3D parameters. Published experience with cementitious rock-like specimens [27], relationships between compressive-to-tensile strength ratios and rock-strength criteria [28], and pile–rock interface shear behavior [29] was also considered qualitatively. Cohesion c and internal friction angle φ were then back-calculated iteratively, and tensile strength σt was adjusted consistently with the calibrated strength level. A parameter set was accepted when both the peak-load discrepancy and the simulated failure pattern were consistent with the experiments. Table 5 lists the calibrated parameters.
Table 5. Material parameters of mortar solid elements.
The steel tubes were represented by shell elements and assigned the Q235 steel grade specified in GB/T 700-2006 [30]. The elastic modulus, Poisson’s ratio, and density in Table 6 are conventional numerical values for structural steel, whereas the shell thickness was derived from the tubular geometry. These quantities are not presented as values prescribed directly by GB/T 700-2006.
Table 6. Shell-element material and geometric parameters.
HRB400 longitudinal reinforcing bars with a diameter of 6 mm were embedded in the grouted bodies and represented by pile structural elements in FLAC3D. Table 7 lists the adopted parameters.
Table 7. Material, geometric, and interface parameters of pile elements.

3.5. Numerical Simulation Results

Figure 10, Figure 11 and Figure 12 present the total reaction-force curves obtained from the FLAC3D simulations for the different surrounding-rock strengths.
Figure 10. Simulated total reaction–displacement curves for the rectangular pile group.
Figure 11. Simulated total reaction-displacement curves for the circular pile group.
Figure 12. Simulated total reaction–displacement curves for the quincunx pile group.
Gravity loading was applied first to establish the initial consolidated state. The nonzero shear load near zero displacement reflects the modeled interlocking and static friction at the contact surface. As shown in Figure 10, Figure 11 and Figure 12, the calibrated curves reproduce the general experimental shape and peak-load scale. The simulated response comprises three stages: an initial rise to the peak reaction, a post-peak decrease as the surrounding material yields, and a subsequent increase as the steel tubes and reinforcing bars carry a larger share of the load. Table 8 lists the peak reactions. Because the same experimental dataset was used for parameter calibration and comparison, the observed agreement represents an internal calibration check rather than independent validation.
Table 8. Peak total reaction forces for different surrounding-rock strengths and pile arrangements.
The simulated peak reactions in Table 8 follow the experimental strength trend and differ only slightly among arrangements at a given mortar grade. To quantify agreement within the calibration dataset, the simulated peaks were compared with the experimental means using Equation (1):
R e l a t i v e   e r r o r = F ¯ e x p − F s i m F ¯ e x p × 100 %
The relative errors calculated using Equation (1) are listed in Table 9.
Table 9. Relative errors between experimental and numerical results for different surrounding-rock strengths and pile arrangements.
For 10 of the 12 conditions, the relative error between the simulated peak reaction and the experimental mean was less than 10%. The circular M10 and M5 errors were 10.48% and 17.74%, respectively. The larger discrepancies at low strength may reflect the substantial experimental variability and the numerical assumption of homogeneous mortar. Because the material and interface parameters were calibrated against the same peak-load dataset, these comparisons indicate internal consistency of the calibrated model rather than independent predictive validation.

3.6. Equivalent Cross-Sectional Area Index Formulation

Consistent with the manuscript title, “equivalent cross-sectional area” is retained as the name of the proposed capacity-equivalence formulation. Its output, Aeq,ref, is used only as an assumption-dependent capacity-normalization index. For a compact comparison between measured group capacity and the adopted reference-strength scale, the discrete micropile group is represented by a virtual homogeneous circular section. Capacity-equivalence and group bearing-mechanism concepts reported by Yang et al. [31] and Fu et al. [32] motivate the approach, but the specific normalization equation is introduced in this study. Aeq,ref does not denote a physical cooperative area and should not be interpreted as an independent measurement of pile–rock interaction.
No normal stress was applied in the laboratory direct shear tests, and the specimens were relatively small. Their failure reflected the combined effects of interfacial bonding and particle interlocking. The test program did not independently measure either pile–mortar interfacial bond stress or mortar peak shear stress. Accordingly, τref denotes an adopted reference peak shear stress rather than a measured material property. The mortar grades were identified with reference to GB 50003-2011 [24]. Values of 1.0 MPa for M5, 2.0 MPa for M10, 3.0 MPa for M15, and 5.0 MPa for M25 were adopted as nominal τref values and adjusted to remain consistent with the model-test response; they are not interface shear strengths prescribed by the standard. The calculation conditionally assumes that the same τref applies to both the pile-group–surrounding-rock system and the reference single pile. The resulting equations are as follows:
Equivalent cross-sectional area index equation:
A e q , r e f = F g r o u p F s i n g l e , r e f × A s i n g l e
Reference single-pile shear capacity equation:
F s i n g l e , r e f = τ r e f × A s , r e f
Nominal reference contact-area equation:
A s , r e f = π × 2 R × L r e f
Geometric single-pile cross-sectional area equation:
A s i n g l e = π R 2
Substituting Equations (3)–(5) into Equation (2) gives Equation (6):
A e q , r e f = F g r o u p 2 τ r e f × L r e f × R
Equation (2) relates the measured or simulated group load to a reference single-pile capacity. Equation (3) calculates this reference capacity from τref, while Equations (4) and (5) define the nominal interface area and geometric single-pile area, respectively. Substitution gives Equation (6). The steel micropile radius R is 0.0095 m. Lref denotes an adopted reference effective height interpreted as an assumed shear-band thickness. A baseline value of 0.005 m and bounds of 0.004–0.006 m were estimated from visible failure patterns rather than independent full-field measurements, as illustrated in Figure 13. Therefore, neither τref nor Lref is treated as a measured material parameter; their influence is evaluated in Section 4.2.
Figure 13. Definition of the adopted reference effective height Lref. The contour colors show the numerical-field distribution for visualization, while Lref is indicated separately and is not defined by the contour colors.
Although the formulation retains the name “equivalent cross-sectional area”, Equation (6) defines Aeq,ref as a reference index within the adopted parameter framework. The ratio Fgroup/Fsingle,ref scales the geometric cross-sectional area of one pile (Asingle) to obtain Aeq,ref. Because Fsingle,ref is calculated from τref and Lref rather than measured independently, Aeq,ref is an assumption-dependent capacity-normalization index with units of area, not a measured geometric or cooperative area. Table 10 defines the variables and identifies their measurement status.
Table 10. Definitions and measurement status of variables used in the reference-index formulation.

3.7. Equivalent Cross-Sectional Area Index Results

Using Equation (6), the experimental means in Table 4 and the simulated peak reactions in Table 8 were converted into Aeq,ref values under the adopted τref and Lref values. Table 11 reports the resulting conditional indices.
Table 11. Calculated equivalent cross-sectional area indices under the adopted reference parameters.
Table 11 shows that Aeq,ref decreases as the adopted τref increases. From M5 to M25, the experimental Aeq,ref values decrease by approximately 55.6%, 61.4%, and 54.1% for the rectangular, circular, and quincunx arrangements, respectively; the corresponding simulated decreases are 53.9%, 53.2%, and 53.7%. The experimental and simulated values are generally similar, except for the circular M5 and M10 conditions. These decreases are conditional normalization results determined jointly by the measured or simulated group load and the adopted reference parameters; they are not physical measurements of a changing cooperative area.

4. Discussion

4.1. Interpretation and Limits of the Equivalent Cross-Sectional Area Index

Under the retained terminology, “equivalent cross-sectional area” names the capacity-equivalence formulation, whereas Aeq,ref denotes its calculated output. Aeq,ref is an assumption-dependent capacity-normalization index expressed in square meters, not a geometric area measured from a specimen. Equation (6) can be written as Aeq,ref = (R/2Lref)(Fgroup/τref), making its parameter dependence explicit. From M5 to M25, the adopted τref increases from 1 to 5 MPa, while the measured mean Fgroup increases by factors of 2.22, 1.93, and 2.30 for the rectangular, circular, and quincunx arrangements, respectively. Because the reference-stress denominator increases faster than the measured capacity, a decrease in Aeq,ref is mathematically expected. Within a given mortar grade, τref and Lref are fixed; consequently, the arrangement ranking of Aeq,ref is identical to that of Fgroup and provides no independent evidence of a superior arrangement. Comparisons across grades are conditional on the adopted τref values. Thus, Aeq,ref is useful only as a transparent normalization metric under the stated assumptions, and its decrease does not demonstrate stronger pile–rock cooperative action.

4.2. Statistical Variability and Parameter Sensitivity

The experimental program comprised 12 conditions, with four independent specimens tested per condition. It therefore included more than three series but did not meet the suggested six tests per series. Table 4 shows substantial scatter in several conditions, particularly rectangular M5 (CV = 43.8%; 95% CI = 16.24–90.88 kN), quincunx M5 (CV = 21.0%), and quincunx M10 (CV = 12.8%). All results were retained. Given n = 4 and the wide confidence intervals, differences among arrangement means should be interpreted descriptively rather than as evidence of statistically significant superiority. A confirmatory program should include at least six specimens per selected condition and prespecified procedures for outlier handling and statistical inference.
Equation (6) is inversely proportional to both τref and Lref. Decreasing or increasing τref by 10% changes Aeq,ref by +11.1% or −9.1%, respectively. Relative to the baseline Lref of 0.005 m, values of 0.004 and 0.006 m change Aeq,ref by +25.0% and −16.7%, respectively. Combining a 10% decrease in τref with Lref = 0.004 m increases Aeq,ref by 38.9%, whereas combining a 10% increase in τref with Lref = 0.006 m decreases Aeq,ref by 24.2%. These calculations define bounding sensitivity cases rather than statistical confidence intervals because τref and Lref were not independently measured and no probability distributions were established. The reported Aeq,ref values should therefore not be used as design parameters. Future tests should measure interface shear strength independently and determine shear-band thickness through full-field displacement measurements or three-dimensional imaging.
The results support a strength-dependent increase in peak shear capacity but provide no evidence that one pile arrangement is generally superior. The nonsignificant arrangement effect should not be interpreted as proof of equivalence among the three arrangements because each condition contained only four specimens.

4.3. Numerical Model Scope and Limitations

FLAC3D (Version 6.0) was selected because a single model can represent the mortar with continuum zones, the steel tubes with shell elements, the reinforcement with pile structural elements, pile–rock coupling with interface springs, and total reaction force through a FISH monitoring function. The numerical parameters were calibrated against experimental peak loads and failure patterns; therefore, agreement with the tests constitutes a calibration check rather than independent validation. Equivalent PLAXIS 3D, ANSYS, or ZSoil models were not available for this revision, and a valid cross-software comparison would require matched geometry, constitutive parameters, interfaces, boundary conditions, loading paths, and meshes. The conclusions are therefore limited to the calibrated FLAC3D framework. Future work should reproduce the same cases in at least one independent platform and compare complete load–displacement curves, failure zones, and peak reactions.

5. Conclusions

Within the investigated mortar grades, pile arrangements, and calibrated FLAC3D framework, the following conclusions are drawn:
(1)
Peak-load behavior. The mean experimental peak shear load increased from M5 to M25 for all three arrangements. For 10 of the 12 conditions, the relative error between the simulated peak reaction and the experimental mean was less than 10%; the circular M5 and M10 errors were 17.74% and 10.48%, respectively.
(2)
Interpretation of Aeq,ref. The term “equivalent cross-sectional area” is retained as the name of the formulation, whereas its calculated output, Aeq,ref, is an assumption-dependent index with units of area. The 54–61% decrease in Aeq,ref from M5 to M25 mainly reflects the faster increase in τref than in Fgroup. Aeq,ref is not a measured physical or cooperative area, provides no information independent of Fgroup when the reference parameters are fixed, and should not be used as a design parameter without independent calibration.
(3)
Arrangement effect. The two-way factorial analysis detected neither a statistically significant overall effect of pile arrangement nor a significant interaction between mortar grade and pile arrangement. The circular arrangement had the highest sample mean at M5 and M10, whereas the rectangular arrangement had the highest sample mean at M15 and M25. These differences do not justify identifying the quincunx arrangement, or any other arrangement, as generally superior. Moreover, the nonsignificant results do not demonstrate equivalence because each condition contained only four specimens.
(4)
Contribution and future work. This study provides an assumption-explicit capacity-normalization framework that links direct shear tests and an internally calibrated numerical model to a conditional reference index. Its present contribution lies in methodological transparency rather than measurement of a physical cooperative area. Before physical interpretation or design application, future work should independently measure pile–mortar interface strength and shear-band thickness, increase selected test conditions to at least six independent specimens, propagate measurement uncertainty, conduct a larger confirmatory program using prespecified statistical procedures, and cross-validate the FLAC3D results with PLAXIS 3D, ANSYS, or ZSoil.

Author Contributions

Conceptualization, S.H.; methodology, S.H. and F.A.; software, S.H.; validation, S.H. and F.A.; formal analysis, S.H.; investigation, S.H., Z.L., R.L., H.J. and S.Y.; resources, F.A.; data curation, S.H.; writing—original draft preparation, S.H.; writing—review and editing, S.H. and F.A.; visualization, S.H.; supervision, F.A.; project administration, F.A.; funding acquisition, F.A. All authors have read and agreed to the published version of the manuscript.

Funding

This work was supported by the Regional Science Fund Project of the National Natural Science Foundation of China (Grant No. 42267020) and the General Program of Yunnan Fundamental Research Projects (Grant No. 202301AT070396).

Data Availability Statement

The data supporting the findings of this study are available within the article.

Conflicts of Interest

The authors declare no conflicts of interest. The funders had no role in the design of the study; in the collection, analysis, or interpretation of data; in the writing of the manuscript; or in the decision to publish the results.

References

  1. Xiang, B.; Ma, J.; He, Y.; Zhu, L.; Zhang, Z. Centrifuge model test of slope reinforced by small-diameter steel pipe row piles. Chin. J. Rock Mech. Eng. 2012, 31, 2644–2652. (In Chinese) [Google Scholar]
  2. Randolph, M.F.; Wroth, C.P. Analysis of deformation of vertically loaded piles. J. Geotech. Eng. Div. 1978, 104, 1465–1488. [Google Scholar] [CrossRef] [Scilit]
  3. Poulos, H.G.; Davis, E.H. Pile Foundation Analysis and Design; John Wiley & Sons: New York, NY, USA, 1980. [Google Scholar]
  4. Zhao, M.; Zou, D.; Zou, X. Settlement calculation of pile foundations with elevated caps by load transfer method. Chin. J. Rock Mech. Eng. 2005, 24, 2310–2314. (In Chinese) [Google Scholar] [CrossRef]
  5. Liang, R.; Yin, Z.-Y.; Yin, J.-H.; Wu, P.-C.; Chen, Z.-J. An enhanced micromechanical rock-pile interface model with application to rock-socketed pile modeling. Int. J. Numer. Anal. Methods Geomech. 2024, 48, 2971–2995. [Google Scholar] [CrossRef] [Scilit]
  6. Jamaleddin, N.; Gabr, M.; Borden, R.; Argall, R.; Lasser, D. Numerical study on micropile group behavior supporting fixed-bottom marine hydrokinetic devices in sandy seabed. Ocean Eng. 2024, 293, 116614. [Google Scholar] [CrossRef] [Scilit]
  7. Swallow, A.W.; Sheil, B.B. Group shape effects on the lateral capacity of pile groups in undrained soil. Géotechnique 2023, 73, 16–29. [Google Scholar] [CrossRef] [Scilit]
  8. Ghassemi, S.; Ekraminia, S.S.; Hajialilue-Bonab, M.; Tohidvand, H.R.; Azarafza, M.; Derakhshani, R. Innovative insights into micropile seismic response: Shaking table tests reveal critical dependencies and liquefaction mitigation. Bull. Eng. Geol. Environ. 2025, 84, 206. [Google Scholar] [CrossRef] [Scilit]
  9. Ghorbani, A.; Hasanzadehshooiili, H.; Somti Foumani, M.A.; Medzvieckas, J.; Kliukas, R. Liquefaction potential of saturated sand reinforced by cement-grouted micropiles: An evolutionary approach based on shaking table tests. Materials 2023, 16, 2194. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  10. Capatti, M.C.; Dezi, F.; Carbonari, S.; Gara, F. Dynamic performance of a full-scale micropile group: Relevance of nonlinear behaviour of the soil adjacent to micropiles. Soil Dyn. Earthq. Eng. 2020, 128, 105858. [Google Scholar] [CrossRef] [Scilit]
  11. Zhu, Y.; Cheng, D.; Yang, K.; Liu, D. Study on calculation model of anchor-cable micropile group considering elastoplastic deformation of soil in front of the embedded pile. Adv. Eng. Sci. 2024, 56, 190–202. (In Chinese) [Google Scholar] [CrossRef]
  12. Deng, Y.; Chen, C.; Yang, Q.; Leng, W.; Ding, R. Model test study on the bearing characteristics of pile groups with different pile spacing. Adv. Eng. Sci. 2025, 1–13. [Google Scholar] [CrossRef]
  13. Liu, F.; Ma, K.; Yang, J. Influence of water content and roughness on the shear characteristics of granite residual soil-concrete interface. Adv. Eng. Sci. 2026, 58, 168–178. (In Chinese) [Google Scholar] [CrossRef]
  14. Ou, Y.; Wang, B.; Xiong, H.; Feng, Y. Application of intensive micropile group-anchor combined support structure in slope engineering. Geotech. Investig. Surv. 2025, 53, 16–22. (In Chinese) [Google Scholar]
  15. Wu, Y.; Fu, H.; Wang, J.; Tian, S.; Liu, P.; Sun, Q. Horizontal bearing capacity and pile-group effect of micropiles on loess ground. Chin. J. Appl. Mech. 2022, 39, 543–553. (In Chinese) [Google Scholar] [CrossRef]
  16. Ren, G.; Wu, Y.; Fan, R.; Dong, B.; Li, G.; Pu, S. Study on pile group effect of micro-pile group foundation in silty clay region. J. Chengdu Univ. Technol. Sci. Technol. Ed. 2022, 49, 111–118. (In Chinese) [Google Scholar] [CrossRef]
  17. Sun, S.; Hu, J.; Zhu, B.; Xia, Y. Formation mechanism and structural characteristics of soil arches in micropile-reinforced slopes. J. Railw. Eng. Soc. 2020, 37, 31–36. (In Chinese) [Google Scholar] [CrossRef]
  18. Kershaw, K.A.; Luna, R. Full-scale field testing of micropiles in stiff clay subjected to combined axial and lateral loads. J. Geotech. Geoenviron. Eng. 2014, 140, 255–261. [Google Scholar] [CrossRef] [Scilit]
  19. Kyung, D.; Lee, J. Interpretative analysis of lateral load-carrying behavior and design model for inclined single and group micropiles. J. Geotech. Geoenviron. Eng. 2018, 144, 04017105. [Google Scholar] [CrossRef] [Scilit]
  20. Rollins, K.M.; Peterson, K.T.; Weaver, T.J. Lateral load behavior of a full-scale pile group in clay. J. Geotech. Geoenviron. Eng. 1998, 124, 468–478. [Google Scholar] [CrossRef] [Scilit]
  21. GB/T 50266-2013; Standard for Test Methods of Engineering Rock Masses. China Planning Press: Beijing, China, 2013. (In Chinese)
  22. JGJ/T 98-2010; Specification for Mix Proportion Design of Masonry Mortar. China Architecture & Building Press: Beijing, China, 2010. (In Chinese)
  23. GB/T 50123-2019; Standard for Geotechnical Testing Methods. China Planning Press: Beijing, China, 2019. (In Chinese)
  24. GB 50003-2011; Code for Design of Masonry Structures. China Architecture & Building Press: Beijing, China, 2011. (In Chinese)
  25. JGJ/T 70-2009; Standard for Test Method of Basic Properties of Construction Mortar. China Architecture & Building Press: Beijing, China, 2009. (In Chinese)
  26. GB/T 50218-2014; Standard for Engineering Classification of Rock Masses. China Planning Press: Beijing, China, 2014. (In Chinese)
  27. Wang, W.; Han, S.; Dong, E.; Peng, G. Simulation on anchorage mechanism of rock mass. J. China Coal Soc. 2023, 48, 177–184. (In Chinese) [Google Scholar] [CrossRef]
  28. Zang, D.; Su, L. The relation between the compressive-to-tensile strength ratio of rock and strength criteria. J. Huainan Inst. Technol. Nat. Sci. 2001, 21, 13–15. (In Chinese) [Google Scholar] [CrossRef]
  29. Xi, B.; Zhang, Z.; Xu, G.; Yin, Y.; Zhang, D. Shear behavior of pile-rock interfaces considering pile formation in deep rock-socketed piles. Geotech. Geol. Eng. 2025, 43, 313. [Google Scholar] [CrossRef] [Scilit]
  30. GB/T 700-2006; Carbon Structural Steels. Standards Press of China: Beijing, China, 2006. (In Chinese)
  31. Yang, S.; Chen, W.; Zhang, X.; Jin, Y. Bearing failure mode of micropile groups based on ultimate resistance. Highw. Eng. 2024, 49, 97–104, 151. (In Chinese) [Google Scholar] [CrossRef]
  32. Fu, P.; He, K.; Zhang, P.; Wang, S.; Xin, X. Design theory of a new micropile group and finite-element study of its anti-slip mechanism. Eng. Constr. 2017, 49, 6–10, 14. (In Chinese) [Google Scholar] [CrossRef]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.