Fabrication and Characterization of High-Performance Channel Electron Multipliers Using Alternating Acid and Base Etching and Atomic Layer Deposition

,
,
,
,
,
,
,
,
and
1
Kunming Institute of Physics, China North Industries Group Corporation, Kunming 650223, China
2
North Night Vision Technology (Nanjing) Research Institute Co., Ltd., China North Industries Group Corporation, Nanjing 211100, China
3
North Night Vision Technology Co., Ltd. Nanjing Branch, China North Industries Group Corporation, Nanjing 211100, China
4
College of Electronic Engineering and Optoelectronic Technology, Nanjing University of Science and Technology, Nanjing 210094, China

Abstract

Channel electron multipliers (CEMs) are continuous dynode vacuum electronic devices used in residual gas analysis and mass spectrometry. Owing to the unique structure and intricate fabrication process of CEMs, developing ultra-high-gain, low-noise devices has long been a major engineering challenge worldwide. The CEM was fabricated from lead silicate glass by preform preparation, capillary drawing, inlet flaring, outlet bending, inlet shaping, cleaning, hydrogen reduction, sandblasting isolation, etching, electron-beam evaporation and atomic layer deposition. We characterized the inner-wall morphology and electrical properties following alternating acid and base etching and atomic layer deposition (ALD) using SEM/EDS, AFM, XPS and electrical measurements. Rounded elemental-lead particles (237 ± 31 nm in diameter) were observed on the channel wall after high-temperature hydrogen reduction. Alternating etching with 1.2 mol/L HCl and 8 wt.% NaOH reduced the root-mean-square roughness (Rq) from 1.28 to 0.15 nm. This reduction is hypothesized to result from the dissolution of elemental Pb by HCl and SiO2 by NaOH. At 2.0 kV, pulse gain increased from 2.00 × 106 to 8.25 × 106, while dark count rate decreased from 54.23 to below 2 counts/s. A nominally 5.5 nm Al2O3 coating deposited by ALD further increased gain fourfold to 3.30 × 107. After an accumulated output charge of 0.158 C, analog gain loss decreased from 89% to 11%. Based on CST Studio Suite 2021, a three-dimensional electromagnetic simulation model of CEM was built. The simulation results show that the pulse full width at half maximum (FWHM) of CEM is 6.4 ns, which is basically consistent with the measured result of 8 ns. Increasing protrusion thickness from 0 to 0.4 mm reduced simulated gain from 8.71 × 106 to 2.60 × 106 at 2.0 kV. The combined experimental and simulation results provide a basis for developing CEMs with improved gain, noise performance and lifetime.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.