Review Reports
- Hatem Affes * and
- Salem Georges Nehme
Reviewer 1: Anonymous Reviewer 2: Anonymous
Round 1
Reviewer 1 Report
Comments and Suggestions for Authors
This manuscript addresses an important topic for wastewater infrastructure durability and presents a meaningful argument that mass loss alone may not adequately reflect the true degradation of concrete exposed to sulfuric acid and sewage environments. The comparison between mass change, pH evolution, and residual flexural strength is interesting, and the study has potential practical value.
However, in its current form, the manuscript requires major revision before it can be considered for publication. The main concerns are that several conclusions are overstated, the mechanistic interpretations are not fully supported by direct evidence, the experimental design introduces comparability issues, and the presentation of methods, statistics, and structure needs improvement.
- The manuscript argues that residual flexural strength is a “superior” indicator and that mass loss “fundamentally fails.” Based on the current results, this should be softened. The data support that mass loss alone can be misleading, but not that it should be fully replaced in all cases.
- The abstract mentions 23 mixtures, while the introduction mentions 26. This should be corrected throughout the manuscript.
- Interpretations such as internal softening, buffering exhaustion, and gypsum barrier effects are plausible, but they are not directly verified. More microstructural or chemical evidence would strengthen the paper, or the discussion should be made more cautious.
- The manuscript refers to realistic MIC and biogenic corrosion, but the field exposure description is limited. More environmental details are needed to support these claims.
- Different cleaning/handling procedures were used for different exposure groups, especially for brushed acid versus sewage/static conditions. This may influence the measured mass change and should be discussed clearly as a limitation.
- Key results should include variability, number of replicates, and statistical significance where appropriate. At present, the reported differences are difficult to evaluate rigorously.
- The mixtures vary in w/c ratio, superplasticizer dosage, and workability class, which makes it difficult to isolate binder effects alone. This limitation should be acknowledged.
- There are section numbering issues, repeated subsection labels, and some unclear table/figure presentation. These should be revised carefully.
- Some wording is too rhetorical for a technical paper, such as “catastrophic,” “false sense of security,” and “definitively proves.” A more balanced tone is recommended.
- The manuscript can suggest that residual mechanical testing should complement current protocols, but it is too early to conclude that standards must be changed based on this study alone.
- Recommended references for introduction: Chloride ions migration and induced reinforcement corrosion in concrete with cracks: a comparative study of current acceleration and natural marine exposure; Effects of transverse crack on chloride ions diffusion and steel bars corrosion behavior in concrete under electric acceleration
Author Response
Thank you for the constructive and insightful feedback regarding our manuscript. We have carefully revised the paper to address all concerns, particularly regarding the tone of our conclusions, the statistical presentation, and the methodological limitations.
1. Softening of Conclusions The tone of the manuscript has been adjusted to be more balanced. The title was changed from "Superior Indicator" to "an Indicator". Claims that mass loss "fundamentally fails" were replaced with "can be an ambiguous metric".
2. Mix Count Consistency The discrepancy has been corrected; the manuscript now consistently refers to 27 distinct concrete mixtures and a total of 486 specimens.
3. Mechanistic Interpretations To remain cautious, we have added terms such as "suggests," "theorized," and "hypothesized" when discussing internal softening and buffering exhaustion.
4. Field Exposure Details We have provided additional environmental context for the sewage exposure, noting that raw municipal influent was collected from the Budapest University of Technology and Economics (BME) and entirely replenished every 7 days to maintain active microbial colonies.
5. Handling Procedures as a Limitation Different cleaning procedures (brushing vs. gentle rinsing) are now discussed in the new "Methodological Limitations" section (Section 6.3) . We acknowledge that these differences prevent a direct one-to-one quantitative comparison of mass change between exposure groups.
6. Statistics and Significance Variability is now reported using standard deviation, and the use of triplicate specimens (n=3) is explicitly mentioned to allow for a more rigorous evaluation of the reported differences.
7. Isolation of Binder Effects We added Section 6.3 to acknowledge that variations in w/c ratio and PCE dosage were necessary to achieve comparable workability across highly different additives, introducing multi-variable complexity .
8. Structural and Numbering Issues Repeated subsection labels and section numbering issues have been resolved. Tables and figures have been reviewed for clarity.
9. Rhetorical Tone Wording such as "catastrophic" and "definitively proves" has been removed and replaced with technical descriptions like "significant" or "confirms the onset".
10. Standards Revision The conclusion has been revised to suggest that mechanical testing "should complement" or "should be incorporated" into current protocols rather than "must mandate" a change.
11. Recommended References We have incorporated the suggested references regarding chloride ion migration and marine degradation to draw parallels with internal corrosion mechanisms.
We believe these revisions have significantly improved the technical rigor and clarity of the paper. We look forward to your further assessment.
Sincerely,
Hatem Affes & Salem Georges Nehme
Reviewer 2 Report
Comments and Suggestions for Authors
The manuscript addresses an interesting and relevant topic and presents a well-structured study with clear potential to contribute to the field. The overall approach is sound, and the results are of interest. The comments below are mainly intended to further improve clarity, completeness of reporting, and alignment with standard scientific practice.
a) References and state of the art
The manuscript would benefit from a moderate expansion of the reference list, particularly by incorporating recent and relevant studies, in order to further strengthen the positioning of the work within the current state of the art.
b) Unit formatting in tables
Please ensure that all units are consistently formatted according to standard scientific notation. For example, m³ should be presented using superscript formatting throughout the tables.
- Table 2 - Consistency classification
The notation used to describe consistency (e.g., “F”) in Table 2 could be clarified. It would be helpful to indicate whether this refers to flow table consistency classes (e.g., F1–F6) and, if applicable, to provide the corresponding measured values (e.g., spread diameter in mm).
c) Mass change measurement
The description of the mass change measurement could be slightly expanded. In particular, it would be useful to indicate the initial moisture condition of the specimens prior to weighing (e.g., oven-dry, saturated surface dry, or conditioned), to ensure full clarity regarding the comparability of the results.
d) pH measurement and interpretation
The manuscript refers to pH and “pH neutralisation”. A brief clarification of the measurement procedure (e.g., type of sample and testing approach) and of the meaning of “neutralisation” in this context would further improve clarity.
e) Statistical treatment and error analysis
The presentation of the results could be further strengthened by briefly indicating whether replicate tests were performed and, where applicable, by including simple statistical indicators (e.g., standard deviation).
Comments for author File:
Comments.pdf
Author Response
Dear Editor and Reviewers,
Thank you for the constructive and insightful feedback regarding our manuscript. We have carefully revised the paper to address all concerns, particularly regarding the tone of our conclusions, the statistical presentation, and the methodological limitations.
a) References and state of the art We have expanded the reference list to include recent 2024 and 2025 studies. This strengthens the positioning of our work within the current state of the art of bacteriogenic sulfuric acid research.
b) Unit formatting in tables All units have been reformatted to follow standard scientific notation. Superscript formatting for $m^3$ and $cm^2$ has been applied consistently across the text and Tables 1 and 2.
Table 2 - Consistency classification Table 2 has been updated to include specific spread diameter measurements (mm) and their corresponding flow table consistency classes (F1–F6) in accordance with European Standard EN 206.
c) Mass change measurement The description has been expanded in Section 2.5.1. We have clarified that all specimens were conditioned in a laboratory oven at 60°C for 24 hours to establish a definitive initial oven-dry mass (M0) prior to exposure.
d) pH measurement and interpretation We have added Section 2.5.2 to clarify that measurements were taken directly from incubation tanks prior to renewal . "Neutralization" is now explicitly defined as the chemical consumption of hydrogen ions (H+) by hydroxyl ions (OH-) released from the cementitious matrix.
e) Statistical treatment and error analysis We have specified that specimens were evaluated in triplicate (n=3) originating from the same batch. Standard deviation values have been added to Table 3 and relevant strength data to indicate intra-batch variability.
We believe these revisions have significantly improved the technical rigor and clarity of the paper. We look forward to your further assessment.
Sincerely,
Hatem Affes & Salem Georges Nehme