Skip to Content
InfrastructuresInfrastructures
  • Article
  • Open Access

28 November 2026

44 Pages

A Comparative Local-to-Global Numerical Study of Four Strengthening Strategies for Unreinforced Masonry Infills in Reinforced Concrete Frames

,
,
and
1
Department of Civil Engineering, Islamic Azad University, Isfahan (Khorasgan) Branch, Isfahan P.O. Box 81595-158, Iran
2
Department of Civil Engineering, College of Engineering, Al-Muthanna University, Samawah 6600, Iraq
*
Authors to whom correspondence should be addressed.
Infrastructures2026, 11(12), 445;https://doi.org/10.3390/infrastructures11120445 
(registering DOI)
This article belongs to the Special Issue Fiber Reinforced Polymer-Ultra High Performance Concrete (FRP-UHPC): Design, Performance, and Application

Abstract

This study presents a comparative local-to-global numerical case study of four strengthening strategies for unreinforced masonry (URM) infill walls in reinforced concrete frames: steel tie rods, basalt fiber-reinforced polymer (BFRP) strips, steel fiber-reinforced concrete (SFRC) overlays, and ultra-high-performance concrete (UHPC) overlays. The strengthened configurations were not independently validated against experiments. Detailed ABAQUS finite element models characterized the nonlinear cyclic responses of unstrengthened and strengthened walls. The resulting response parameters were incorporated into Pivot hysteretic representations in SAP2000 to assess seismic response under six selected near-field and far-field ground-motion records. At the wall level, SFRC increased peak lateral strength by approximately 83.3% and cumulative work along the recorded wall-level loading path by approximately 125.2% relative to the unstrengthened URM model, whereas UHPC produced the highest peak lateral strength, approximately 125.6% above URM. At the building level, SFRC and UHPC reduced maximum inter-story drift by approximately 27.8–50.0% and 33.3–59.1%, respectively, and peak roof displacement by approximately 29.1–53.7% and 29.7–59.8%, respectively, relative to the URM-infilled frame. Tie-rod and BFRP configurations exhibited higher drift demands than the URM reference under the analyzed records. Peak base shear and roof acceleration varied with ground motion and strengthening configuration. The work measure includes possible stored-energy changes because the recorded paths do not close. These findings are limited to the adopted numerical models and selected records.

1. Introduction

Seismic rehabilitation of existing masonry and masonry-infilled structures requires an understanding of local wall behavior and an assessment of its influence on the structural system as a whole [1,2]. This distinction is particularly important for reinforced-concrete (RC) frames containing unreinforced masonry (URM) infills.
Hospitals are selected for the present application because structural and nonstructural response demands may affect their ability to remain operational after an earthquake [3]. Detailed finite element analysis provides a means of comparing specified wall-strengthening configurations [4]. However, numerical predictions depend on constitutive assumptions, boundary conditions, and the available validation evidence.
Masonry vulnerability depends on material properties, geometry, connections, and interaction with the surrounding structure [5,6,7]. Relevant failure mechanisms include sliding, diagonal cracking, rocking, toe crushing, and loss of out-of-plane stability [8,9]. These mechanisms require different modeling assumptions. Detailed micro-models distinguish masonry units, mortar joints, and their interfaces, whereas homogenized continuum models represent masonry using effective material properties [10]. Simplified frame, strut, and shell representations reduce the number of degrees of freedom required for building analysis [11,12,13]. Shell elements are a discretization choice; their use does not, by itself, imply linear or isotropic material behavior. The appropriate level of detail depends on the response quantity being investigated and the evidence available for calibration.
Previous finite element studies have investigated FRP reinforcement of historical masonry, cementitious jacketing, and CFRP strengthening [14,15,16]. More detailed treatments of unit–mortar and reinforcement–substrate interactions allow local damage and relative movement to be examined [17,18].
Such detail helps interpret wall response, but it increases the calibration and computational demands of models intended for repeated building-level analyses [19]. Consequently, the use of ABAQUS or SAP2000 does not, by itself, establish predictive accuracy; agreement with relevant tests and consistency of the transferred mechanical quantities remain necessary.
The retrofit literature includes approaches that modify wall resistance and others that alter the overall structural response. Dampers and related interventions have been investigated for existing buildings [19,20,21], while tie rods, shear-energy dissipation devices, and reinforced-concrete jacketing provide additional strengthening options [22,23,24]. Vulnerability assessment helps identify the mechanisms to be addressed before selecting an appropriate intervention [25].
Cementitious composites, including engineered cementitious composites and textile-reinforced mortar, have also been investigated as strengthening materials [1,26,27]. Their performance depends on the constitutive law, reinforcement arrangement, anchorage, and interaction with the masonry. These studies motivate comparisons within a defined modeling scope rather than a universal ranking of retrofit techniques.
For global structural analysis, simplified representations may combine nonlinear hinges in reinforced-concrete members with links or diagonal struts representing masonry infills [28,29]. Accounting for infills changes the modeled stiffness, force distribution, and deformation response relative to a bare-frame idealization [30]. Equivalent-frame and shell approaches have also been used to assess masonry buildings [31,32].
Studies of FRP, textile-reinforced mortar, and concrete jacketing illustrate the range of strengthening systems examined numerically [33,34], while experimental comparisons provide a basis for assessing specific wall models [35]. However, calibrating a model for a particular material, geometry, and loading history does not establish its accuracy for every strengthening configuration.
Vulnerability assessment [36] and studies of cyclic masonry behavior [37] demonstrate the need to relate the selected analytical idealization to the relevant failure mechanisms. Existing rehabilitation provisions, including ASCE and FEMA guidance, provide assessment frameworks [2,38]. However, the present study, which uses six pairs of ground-motion records, is not presented as a code-compliant performance assessment. Here, the research question is how four specified strengthening configurations affect local wall response and the computed global response when evaluated through the same numerical workflow. The influence of unverified interface behavior and strengthened-wall calibration must therefore remain explicit when interpreting the comparison.
Penna et al. [39] developed a two-node macro-element for cyclic in-plane masonry response, including interacting shear and flexural damage and comparisons with pier tests. This provides an alternative to detailed continuum analysis for nonlinear building assessment. Its constitutive calibration differs from the present backbone-to-link transfer. Masonry vulnerability [36] and experimental–numerical CFRP strengthening studies [40] therefore provide complementary context, but neither establishes independent validation of the four strengthened configurations examined here.
Interface treatment is an additional source of variation among composite-strengthening models. D’Altri et al. [41] conducted analyses assuming perfect adhesion between FRP and masonry, represented substrate damage, and compared the results with single-lap shear tests. Facconi et al. [42] investigated masonry strengthened with steel fiber-reinforced mortar (SFRM) using analytical and numerical models supported by experimental comparisons. These studies highlight the need to specify the adopted bond idealization, material system, and validation target separately. Their validation does not automatically extend to the BFRP, UHPC, or SFRC configurations considered in the present study.
Regarding modeling strategy and the associated validation trade-off, detailed continuum or simplified micro-models can represent local stresses and damage mechanisms, but require substantial meshing effort, parameter calibration, and computational time. Equivalent-strut and concentrated-plastic-hinge models substantially reduce the computational cost of nonlinear response-history analyses of multi-story buildings. However, they require calibration of the axial backbone, cyclic degradation, and frame–infill interaction.
This study uses ABAQUS to generate local wall-response inputs and SAP2000 Pivot links to compare global response demands. This transfer is an engineering approximation rather than a constitutive innovation or a substitute for independent tests. Since experimental comparison is available only for the unstrengthened reference wall, strength and energy predictions for the rehabilitated configurations remain sensitive to the assumed material and interface laws. This trade-off motivates the selected computational workflow but limits claims of superiority over independently calibrated micro- or macro-models.
Equivalent-frame studies of load-bearing URM buildings help define the scope of simplified global models. Quagliarini et al. [43] discuss the applicability limits of equivalent-frame assessment, while Petrovčič and Kilar [44] incorporate interacting failure mechanisms into a plastic-hinge representation. These studies focus on masonry piers and spandrels, whereas the present application represents masonry panels within an RC frame using diagonal links. Their relevance therefore lies in the need to match the idealization to the governing mechanisms, rather than in providing evidence that an infill-link model reproduces all failure modes of masonry buildings.
Assessment scale also influences retrofit selection. Ferreira et al. [45] reviewed vulnerability assessment methods and interventions across different scales, while Keshmiry et al. [46] placed strengthening within a broader process encompassing condition assessment, repair, and monitoring. These perspectives support interpreting a numerical comparison of a single building as a configuration-specific study. They do not establish hospital functionality or safety without assessments of foundations, anchorage, and nonstructural components.
For composite strengthening, Petrovčič and Kilar [47] compare externally bonded FRP layouts in terms of their influence on global URM-building response and material use. Petrovčič et al. [48] also investigate selective and comprehensive fiber-reinforced cementitious matrix (FRCM) interventions in post-war masonry building typologies.
Both studies highlight the importance of strengthening distribution and the original structural layout alongside local resistance. Their FRP and FRCM systems and load-bearing masonry typologies differ from the BFRP strips and SFRC/UHPC overlays applied to RC-frame infills in the present study. Their results are therefore not used as direct validation of the strengthening configurations examined here.
A remaining challenge in the seismic assessment of reinforced-concrete (RC) frames with unreinforced masonry (URM) infills is the transfer of detailed nonlinear wall response into computationally efficient frame-level representations. This study investigates four strengthening configurations—steel tie rods, basalt fiber-reinforced polymer strips, steel fiber-reinforced concrete overlays, and ultra-high-performance concrete overlays—using a consistent local-to-global numerical workflow. ABAQUS wall-level simulations provide nonlinear response data, and corresponding parameters are transferred to SAP2000 Pivot-type links for a comparative assessment of a four-story RC frame under six selected earthquake record pairs. The contribution is a comparative integration of wall-level and frame-level modeling for these defined configurations; it does not constitute a new validated constitutive law or an independently verified prediction for other masonry systems.

2. Methodology

The methodology comprises reproduction of reference models, case-specific benchmark comparisons, and development of the study configurations. Local analyses in ABAQUS (2020) represent the unstrengthened URM wall and four strengthened-wall configurations. The unstrengthened-wall modeling approach is assessed against the CL-05 experimental benchmark, and the wall responses provide backbone parameters for subsequent global analyses. In SAP2000 (v23), nonlinear axial links with Pivot hysteresis represent the infills within the RC frame. The S1B-1 reference-frame comparison provides a separate benchmark for this representation; it does not independently validate the strengthened-wall configurations or their complete cyclic response. The building models are then subjected to nonlinear response-history analyses under the selected near- and far-field ground-motion pairs. The outcome is a comparative response assessment for the adopted models and records. The wall-level and building-level representations are referred to as local-based and global-based models, respectively. Figure 1 summarizes the methodology.
Figure 1. Computational methodology for the seismic local-to-global assessment of reinforced-concrete frames with masonry infills. (The red outlines group the three workflow stages, and the connectors show the sequence and the connections between the local and global modeling tasks. The labels in the boxes identify each modeling task.)

2.1. Local-Based Model

The local-based models are developed to compare the strengthening configurations relative to the reference-wall capacity. The unstrengthened-wall finite element modeling approach in ABAQUS is assessed against the CL-05 experimental benchmark; the strengthened configurations are not independently validated against experiments. Four strengthening techniques are modeled using a common nominal analytical shear-contribution target (52% of the reference-wall shear capacity) to support comparative design. This is a selected normalization target, not a demonstration that the realized nonlinear capacities of the four systems are equal. The strengthening methods are as follows.
Tie-rod system: The framework accounts for the tensile capacity of steel rods anchored to the wall for each side, considering their placement and interaction with the masonry. This method is adopted from Rinaldin et al. [22], in which steel tie rods were used in a form of a cross to strengthen a URM wall. The idealized tie-rod contribution is activated in tension; compression resistance is neglected in this analytical idealization. For implementation, the process starts with assessing the wall’s condition to determine rod placement. Then, holes are drilled through the masonry at the corners and mid-span of the wall where the square end plates are mounted to distribute loads evenly. Steel rods connect the end plates to form a cross-layout brace system. The shear force contribution from the tie rod (Vtierod ) is then derived by considering the number of tie rods (Ntierod ), an assumed analytical reduction factor (RF = 0.8), whose independent calibration and transferability were not established in the present numerical assessment, the cross-sectional area based on the tie rod diameter (dtierod ), multiplied by the yield stress and the cosine of the placement angle (θ) to resolve the axial force into the in-plane lateral resistance direction [22].
The reduction factor RF = 0.8 is an assumed analytical allowance for local deformation and vertical shortening. Its value was not independently calibrated against tests or assessed through a sensitivity analysis; consequently, the nominal tie-rod contribution is conditional on this assumption.
V tierod = N tierod ⋅ RF ⋅ π d tierod 2 4 ⋅ σ y , tierod ⋅ cos θ
FRP strips: This strengthening method has been used in several studies to strengthen the URM walls and based on various results. A surface-mounted cross-layout is adopted here as one investigated configuration; this study does not establish its universal superiority over other FRP layouts. Basalt fiber-reinforced polymer (BFRP) strips were selected for the investigated model. A comparative life-cycle cost assessment of alternative fibers was not performed. This method of rehabilitation enhances the wall’s overall integrity by transferring stresses from the URM wall to the strips, under the assumed in-plane, perfect-bond numerical conditions; out-of-plane failure was not separately assessed. Implementation begins with designing the strip layout to target specific vulnerabilities [18,49]. In this study, the contribution of two-side, cross-layout FRP strips is evaluated based on their stiffness, effective strain, and geometric arrangement on the wall. The shear contribution (VFRP) from FRP strips is calculated [18]:
V FRP = ζ FRP × E FRP × ϵ FRP γ FRP × A FRP total
where ζFRP is the efficiency coefficient, EFRP is the elastic modulus, ϵFRP is the effective strain, γFRP is the environmental factor, and AFRP total is the total effective FRP area. The cross-sectional area of one FRP strip (AFRP) is obtained:
A FRP = t FRP × w FRP
where tFRP is the thickness and wFRP is the width of FRP strip. The total effective FRP area is then calculated:
A FRP total = num strips × num faces × A FRP × cos θ FRP
where num strips is the number of FRP strips per face, num faces is the number of the wall’s faces with FRP, AFRP is the cross-sectional area of one FRP strip, and θFRP is the angle of FRP placement.
UHPC cover: These covers are overlays of a specialized concrete mix featuring fine particles, low water content, and often fibers, used to strengthen URM walls by adding a durable layer that improves compressive and tensile properties. This method confines the URM wall to distribute loads better and resist cracking, particularly useful in areas prone to high-impact or cyclic stresses. To implement, the cover thickness is calculated and used as double-sided application. Installation includes cleaning the masonry and spraying the UHPC mix [50]. The shear contribution (VUHPC ) from UHPC coating is calculated [50,51,52,53]:
V UHPC = N UHPC × t UHPC × f t UHPC × h
where NUHPC is the number of UHPC coating layers, tUHPC is the thickness of a single UHPC layer, ftUHPC is the tensile strength of UHPC, and h is the wall height.
SFRC cover: These covers, similar to UHPC covers, strengthen URM walls through a concrete coating infused with steel fibers, which enhance the material’s toughness and ability to bridge cracks, thereby improving the wall’s shear resistance and energy absorption under dynamic loads [54,55]. The shear contribution from the SFRC coating (VSFRC) is determined by considering the fiber properties, concrete strength, and coating configuration, with adjustments for cracking behavior and shear resistance, and strut geometry [42]:
V SFRC = m SFRC × f tu × N SFRC × t SFRC × h 2 × sin θ SFRC 2
where mSFRC is the redundancy factor, ftu is the design residual tensile strength, NSFRC is the number of SFRC coating layers, tSFRC is the thickness of a single SFRC layer, h is the wall height, and θSFRC is the strut angle. The shear stress at first cracking of the SFRC coating (vcr ) is calculated:
v cr = f t SFRC b × 1 + σ 0 f t SFRC
where ftSFRC is the tensile strength of SFRC, b is the bounded stress-distribution factor b = min [1.5, max(1, h/l)], and σ0 is the normal stress. The average slope of struts in SFRC (θSFRC ) and the minimum strut angle based on geometry (θmin ) are calculated:
θ SFRC = min arctan f t SFRC + σ 0 b × v cr × 180 π , 90
θ min = arctan h l × 180 π
Note that in the case of θmin ≥ θSFRC, then θSFRC = θmin. The design residual tensile strength of SFRC (ftu) is obtained:
f tu = max 0.9 × f t SFRC , f t SFRC025
The SFRC design expressions are adapted from the SFRM model of Facconi et al. [42]. The coefficient b = min [1.5, max(1, h/l)] is distinct from the geometric ratio h/l used for θmin. Angles are evaluated consistently in degrees. The max operator in Equation (10) follows the source residual-strength formulation, with the second argument denoting tensile resistance at a crack width of 0.25 mm. Transfer of this SFRM formulation to the adopted SFRC remains a modeling approximation. For the adopted wall geometry, h/l = 2900/5250 = 0.55238 and b = 1. In the paired cracking-stress and strut-angle expressions, bv cr = ft SFRC × 1 + σ 0 f t SFRC ; consequently, consistent correction of this coefficient changes the intermediate cracking stress but not the strut angle or the coating resistance calculated from it. With the stated material inputs and 12 mm coating on each face, the analytical angle is approximately 48.53° and the coating shear contribution is 495.22 kN. This algebraic consistency check does not independently validate the adopted overlay design or its finite-element response.
Where ftSFRC is the tensile strength of SFRC and ftSFRC025 is the residual tensile strength at a 0.25 mm crack width. The redundancy factor for the diagonal shear mechanism (mSFRC) is evaluated:
m SFRC = max 1 , 2 × l h − 1
Unit convention for Equations (1)–(6): stresses and elastic moduli are expressed in MPa (N/mm2), and thicknesses, widths, diameters, and heights are expressed in mm. The resulting force is therefore in N and is divided by 1000 when reported in kN. This unit conversion is separate from calibration or validation of the resistance expressions.
To validate the FE modeling in ABAQUS, CL-05 specimen studied by Magenes et al. [56] was selected as a benchmark. The reason behind this choice was the detailed information provided in the study. The CL-05 test involved a full-scale URM wall made from Italian-style lightweight perforated clay blocks (void content: around 45 percent, block size: roughly 250 mm long by 300 mm thick by 190 mm high). These blocks were laid with standard mortar (about 5–15 mm thick) filling both horizontal and vertical joints. The wall itself measured 2500 mm in length, 300 mm in thickness, and 2600 mm in height. Researchers applied a constant vertical load equivalent to an average stress of 0.68 MPa across the top, simulating typical building pressures which is about 10 percent of the maximum axial capacity applied on the wall. The initial tests performed on the flexural, compression and tensile strength of material showed the mortar had a bending resistance of about 2.45 MPa and crushing strength of 7.38 MPa, while the assembled masonry reached a compression capacity of 9.5 MPa with a stiffness modulus of 5905 MPa. Diagonal shear tests on similar panels gave a cracking tension value of 0.278 MPa to indicate the failure patterns [56]. To model the benchmark model (CL-05) in ABAQUS, a three-dimensional solid part representing the URM wall was created and discretized with 18,921 nodes and 15,600 solid elements, for which a solid section was assigned. Enhanced hourglass control and element deletion were enabled to improve stability during the cracking and crushing process. The wall was then assembled in the global coordinate system, and two reference nodes were defined at the top and bottom to facilitate the application of loads and boundary conditions through kinematic coupling constraints. The bottom reference node was coupled with the wall base, while the top reference node was coupled with the top surface to apply controlled loading and displacement. The nonlinear response of the masonry wall was simulated in ABAQUS using the CDP constitutive model in which the elastic properties were defined by a modulus of elasticity of 5909 MPa and Poisson’s ratio of 0.15. Plasticity parameters included a dilation angle of 20°, flow eccentricity of 0.1, a stress ratio fb0/fc0 of 1.16, a viscosity parameter of 0.0001, and Kc = 0.67. These data were extracted from a numerical simulation by Hernoune et al. and calibrated to match the experimental results using ABAQUS. Their URM wall, made of clay brick and cement-lime mortar, was a close match to the materials used in the CL-05 specimen. [40]. Boundary conditions were assigned such that the wall base was fully restrained against both translation and rotation, while the top was fixed against vertical movement and rotation but remained free for in-plane lateral displacement. Loading was applied in two stages. In the first step, a uniform axial pressure of 0.68 MPa was applied on the top surface to represent vertical pre-compression. In the second step, lateral cyclic loading was introduced by prescribing a displacement history to the top reference node through a predefined amplitude function consisting of multiple cycles with gradually increasing displacement levels. Figure 2 shows the ABAQUS mesh of the CL-05 benchmark.
Figure 2. ABAQUS mesh of the CL-05 experimental benchmark used to check the unstrengthened-wall modeling approach. (The cyan surface represents the wall model, and the dark lines delineate the finite element mesh. RP-1 and RP-2 mark the upper and lower reference points, respectively. The axis triad indicates the model directions.)
Following the validation of the FE modeling procedure, a URM wall, with dimensions related to the global-based model and specified in Table 1, is designed for this purpose. The material properties, loading conditions, and boundary conditions are configured based on the experimental model [56].
Table 1. Wall geometry and units (mm).
The minimum shear resistance (Vmin) is 949.391 kN, corresponding to the governing shear failure mode which is DSS. The average shear stress (τavg) across the wall is 0.603 MPa. Additionally, the total shear contribution (VContribution) is calculated as 493.683 kN, which corresponds to approximately 52.0% of the calculated unstrengthened URM shear resistance (949.391 kN). This percentage was selected as a nominal analytical design target for comparing retrofit options; the actual nonlinear strength contributions depend on each modeled system and were not constrained to be identical. The models are analyzed under cyclic loading. The adopted approach to creating a masonry wall model is as the same as the benchmark model. The dynamic explicit solver is used and the nonlinear effects of large displacements are considered. The top and bottom of the wall are also coupled to a reference point so that boundary conditions and loading can be applied at those points, as well as the outputs of shear force and lateral displacement of the wall. After defining the interactions, it is time to define the loads and boundary conditions, which are defined as a fixed conditions at the bottom of the wall, so that all displacements and rotations are fixed. Overhead loading is applied similar to the experimental model in the first step. Then, cyclic loading is applied to the top of the wall as a loading amplitude (Figure 3). In the end, to perform model analysis in ABAQUS, the model is meshed using C3D8R, which is a three-dimensional solid element with reduced integration (Figure 4). The final step of this section is the extraction of the result which is a hysteretic load−displacement curve [26]. A MATLAB code is written to process and analyze this curve and extract the Pivot parameters.
Figure 3. Displacement-controlled cyclic loading protocol used in the ABAQUS wall analyses.
Figure 4. ABAQUS model of the study-specific unstrengthened URM infill wall (distinct from CL-05 benchmark in Figure 2).
The URM wall is rehabilitated using the strengthening methods. The modeling procedure of each method in ABAQUS is adopted from an existing study and it is implemented on the base model which has identical material properties, while its geometry is adjusted to more accurately reflect a real-world scenario. To simulate the behavior of the employed materials in ABAQUS, the stress−strain relationships for the masonry unit, brick, mortar, steel rods and endplates, FRP strips, UHPC, and SFRC coatings are defined based previous studies. The FE modeling assumptions of the tie rod system are adopted from Rinaldin et al. in which tie rods are used in a form of a cross-shaped layout (Table 2). The endplates and rods are modeled using deformable C3D8R elements [22].
Table 2. Tie rod properties.
The methodology for modeling FRP material in ABAQUS is adapted from Zhang et al. [18]. FRP material is modeled using shell elements in a form of strips and the interaction between the wall and FRP is a full bond using tie constraint. FRP strips are considered to be orthotropic and their behavior is assumed to be lamina which remains elastic [57]. Table 3 and Table 4 present the elastic properties and geometric parameters of BFRP fed into ABAQUS and other designed parameters.
Table 3. Orthotropic lamina elastic properties of BFRP.
Table 4. FRP properties.
Table 5 summarizes the element types, constitutive models, interaction types, compressive and tensile strengths, elastic modulus, steel fiber content, density, and Poisson’s ratio for FE analysis.
Table 5. Material properties and constitutive models defined in ABAQUS.
The UHPC coating method is adopted from the numerical study of Liu and Liu [58]. Accordingly, a 15-mm-thick UHPC layer on each face of the wall is created using a solid element (C3D8R) and its behavior is simulated based on the CDP constitutive model. The interaction between the UHPC layer and the wall is a full bond using tie constraint [24]. The SFRC coating is adopted from Najafgholipour et al.’s research. According to their study, the SFRC layers are tied to the masonry wall without any slipping at the contact surface. The CDP constitutive model is also used to simulate the SFRC coating whose data are mentioned in Najafgholipour et al.’s study and it has 1 percent fiber volume fraction. The C3D8R element is used to create two 12 mm layers of SFRC that cover each side of the wall [59].
Previous studies provided case-specific evidence for perfect-bond modeling. D’Altri et al. [41] compared perfect-adhesion models of FRP bonded to masonry with single-lap shear tests, representing debonding through substrate damage.
Facconi et al. [42] used bonded layered-shell models and reported peak-load differences of approximately +6% and −1% for two tests on walls strengthened with steel fiber-reinforced mortar (SFRM).
These comparisons involved different materials, interfaces, and loading protocols. Therefore, they do not quantify the error associated with the ABAQUS tie constraints used here or independently validate the four strengthened-wall models.
Interface modeling limitation. The masonry-to-BFRP, masonry-to-UHPC, and masonry-to-SFRC interfaces were represented by tie constraints, imposing displacement compatibility and preventing relative separation or slip. This is an idealized perfect-bond assumption rather than an experimentally verified interface law for the strengthened specimens. Consequently, the simulations cannot predict adhesive debonding, coating delamination, interface shear sliding, or bond degradation during cyclic loading. In particular, the damage contours near crossing BFRP strips should not be interpreted as evidence of simulated FRP debonding. Because interface failure can reduce effective lateral resistance and hysteretic energy dissipation, the calculated benefits should be interpreted as conditional on adequate bond and anchorage. No independent interface-stiffness sensitivity study was established in the available results.
Material-modulus clarification: The 5905 MPa value mentioned in the CL-05 experimental benchmark discussion refers to the reference specimen used for model verification, whereas 5909 MPa is the adopted URM elastic modulus in the present wall configurations (Table 5). These values describe different modeling contexts and should not be presented as interchangeable inputs. The value 59,090 MPa identified in the review is inconsistent with the adopted 5909 MPa wall-model parameter and is not used in the present material-property table.
For the adopted finite element configurations, the BFRP strip thickness was 0.84 mm (Table 4), the UHPC overlay thickness was 15 mm on each face, and the SFRC overlay thickness was 12 mm on each face. The URM elastic modulus used in the wall model was 5909 MPa (Table 5).
BFRP input traceability. The adopted longitudinal modulus E1 = 96,000 MPa and strip thickness t = 0.84 mm (Table 3 and Table 4) are consistent with the FRP input-preparation and numerical design datasets associated with this study. The FRP representation uses S4R shell elements, an orthotropic lamina, and a tie-constraint interface with the masonry substrate. This specifies the idealized model inputs and does not constitute independent confirmation of the final completed solver job.
Mesh-discretization limitation. The ABAQUS models employ the element formulations reported in Table 5, but the available analysis records do not document a systematic element-size refinement or mesh-convergence assessment. Therefore, numerical convergence of peak resistance, post-peak softening, strain localization, and CDP damage fields cannot be established from the present evidence. In particular, localized damage and softening may depend on the adopted characteristic element length and regularization assumptions. The model-to-experiment comparison supports the selected benchmark response only; it must not be interpreted as a mesh-objectivity demonstration for all strengthening configurations. A controlled mesh-refinement study is required before mesh-independent local damage or failure predictions can be claimed.
The main challenge of this study is to simulate the behavior of the masonry unit and the SFRC and UHPC coating using the CDP constitutive model. Numerous studies have introduced refined versions of the CDP method, each offering varying levels of accuracy [26,49,50,58,60,61,62,63,64,65,66,67]. Table 6 presents the adopted CDP plasticity parameters for URM, UHPC and SFRC. The adopted UHPC and SFRC material properties are listed in Table 7 and Table 8, respectively.
Table 6. CDP plasticity parameters.
Table 7. UHPC properties.
Table 8. SFRC properties.
The Pivot hysteresis model was used to represent nonlinear cyclic response in SAP2000, with backbone parameters obtained from corresponding ABAQUS force–displacement responses. Extraction of backbone parameters alone does not independently validate unloading, reloading, or stiffness degradation behavior. Quantitative comparison of complete cyclic responses and the sensitivity of Pivot degradation parameters remain to be verified.
The CDP inputs in Table 6 for URM, UHPC, and SFRC are as follows: URM (dilation angle of 20°, eccentricity of 0.1, fb0/fc0 of 1.16, Kc of 0.67, viscosity of 0.0001), UHPC (31°, 0.1, 1.16, 0.6667, 0.005, respectively), and SFRC (25°, 0.1, 1.16, 0.6667, 0.005, respectively). The values of 0.67 and 0.6667 differ by rounding and do not establish materially different yield-surface shapes. The viscosity entries are numerical regularization parameters in the adopted CDP formulation; their values are reported as model inputs, not independently calibrated material constants. No viscosity-parameter sensitivity or mesh-objectivity study was performed; therefore, the possible influence of regularization on the predicted cyclic response remains a limitation.
The Concrete Damaged Plasticity (CDP) parameters adopted for URM, UHPC, and SFRC are summarized in Table 6. The values of Kc reported as 0.67 and 0.6667 are numerically close, while the viscosity parameters differ between the URM and overlay materials. A systematic sensitivity analysis of these CDP plasticity parameters was not performed. Their potential influence on cyclic strength, stiffness degradation, and energy dissipation is therefore a modeling limitation.
Figure 5 illustrates the compressive stress−strain relationships for all five materials: brick, mortar, URM, UHPC, and SFRC.
Figure 5. Stress−strain relationships of brick, mortar, URM, UHPC, and SFRC materials.

2.2. Global-Based Model

The global modeling stage uses nonlinear axial links with Pivot hysteresis to represent the wall responses within RC frames, following the approach of Cavaleri and Di Trapani [68]. Backbone parameters can be obtained from the analytical framework presented below or from experimental or numerical force–displacement responses. In the present study, the parameters for the five wall configurations are extracted from the ABAQUS responses and assigned to multilinear plastic link elements in SAP2000. The S1B-1 unstrengthened infilled-frame benchmark provides a separate comparison with the quasi-static cyclic results reported by Cavaleri and Di Trapani [68]. Its geometry, element properties, boundary conditions, and loading protocol are reproduced in SAP2000. This reference-case comparison does not independently validate the complete cyclic response of all five transferred wall representations or the seismic response of the three-dimensional building models.
In SAP2000, a link element is provided to connect two nodes to represent linear, nonlinear, and frequency-dependent behavior. Each link element determines the force−displacement relationships for six internal deformations. In cases that the link element is defined with a linear or nonlinear feature, it can be efficient based on the type of analysis. The frequency-dependent mode is also efficient for frequency-dependent analysis. SAP2000 offers different types of link elements, among which the multilinear plastic type with Pivot hysteresis is used in this research. This link shows plastic properties with different loading and unloading behavior, and therefore, it dissipates the energy according to different hysteresis models. It has also additional parameters to control deteriorating hysteresis cycles. The reason to name the Pivot constitutive model is because the loading and unloading behavior tends to a certain point, which is called the Pivot point. To define the Pivot model, parameters such as α1, α2, β1, β2, and ƞ must be defined in which α1 represents the pivot point for unloading up to the zero point from the positive force side. If this is done from the side of negative force, this point is called α2. β1 determines the pivot point for reverse loading from zero point to positive force. If this is done from the side of the zero point towards the negative force, this point is called β2. ƞ also shows the amount of deterioration of elastic slopes after elastic deformation [69].
To accurately simulate the behavior of a masonry wall in SAP2000, a diagonal compression element based on the Pivot model can be used, which is significant flexibility in modeling asymmetric compressive-tensile behavior, particularly for masonry walls that show resistance only under compressive stresses. The general Pivot curve can be fully obtained when the values of tension and compression strength that is Fy1 and Fy2, initial stiffness, and peak strength are available. Accordingly, with the intersection of the horizontal lines based on the values of α2Fy2, α1Fy1, β1Fy1, and β2Fy2 and the lines with the initial elastic slope, the initial pivot points, namely P1, P4 and P2, P3, as well as the intersection points PP2 and PP4, are defined. When the Pivot hysteresis model is used to model the behavior of masonry walls, various simplifications are made. In this methodology, since the masonry walls show no tensile strength, α1, and β1 are considered equal to zero. In addition, based on experimental data, masonry walls do not undergo hardening in reverse loading until total plastic deformation is reached. Accordingly, the β2 is also equal to zero. Therefore, the hysteresis law is determined only based on α2. The P3 point, which becomes the main pivot point, defines the loading direction when the value of the yield stress, Fy2, and the α2 parameter are determined. The points S1, S2, and S3 at the maximum compression show the yield, the peak, and the restoring force corresponding to a 30 percent decrease in the peak strength, respectively [68].
To derive the parameters of the equivalent diagonal strut and the pivot hysteresis model, the following theoretical relationships can be used. In the first step, the geometric and material characteristics of the masonry wall must be obtained. To this end, the net height and length of the frame define the diagonal inclination of the infill panel:
θ = arctan ( h n l n )
where θ is the diagonal inclination of the masonry infill panel, hn is the net height of the frame, and ln is the net length of the frame. The diagonal length of the infill panel is obtained from the following.
The tie-rod and equivalent-strut angles in Equations (1) and (12) are measured from the horizontal along their respective member axes. The symbols refer to different members and are defined by the corresponding geometry; equal numerical values are not assumed.
Kinematic interpretation of the idealized single equivalent diagonal. Let θ denote the diagonal inclination measured from the horizontal, Δh denote the panel lateral displacement, Vh denote its horizontal shear, δd denote the axial shortening of the compression diagonal, and Nd denote the diagonal axial force. Under the idealized pin-ended, rigid-frame-geometry projection, δd ≈ Δh cos θ and Vh = Nd cos θ; hence, Nd = Vh/cos θ and the corresponding axial backbone stiffness is kd = kh/cos2 θ. These expressions require consistent compression signs and units, and represent a geometric transformation rather than independent identification of the implemented SAP2000 links.
d = h n 2 + l n 2
where d is the diagonal length of the masonry panel. A geometric aspect ratio coefficient is defined as:
z = l h
where z is the frame aspect-ratio coefficient, h is the height (axis-to-axis) of the frame, l is the length (axis-to-axis) of the frame. The elastic lateral stiffness of the bare frame is computed from:
k b = F b Δ b
where kb is the lateral stiffness of the bare frame, Fb is the applied lateral load on the bare frame, and Δb is the corresponding lateral displacement. The ultimate moment capacity of the columns may be represented in the simplified form:
M u = h n F b 4
where Mu is the ultimate moment demand in the columns. The diagonal compression capacity of the infill is estimated as:
F w = f v 0   t   d
where Fw is the diagonal compression strength of the masonry panel, fv0 is the masonry shear/compression strength parameter, t is the masonry thickness. A strength ratio parameter relating masonry to bare-frame strength is defined as:
α s = F w cos θ F b
where α s is the ratio of masonry shear capacity to bare-frame lateral capacity. An empirical expression defines the dimensionless peak-strength amplification factor of the infilled frame:
Δ s = C 1 ( α s f v 0 ) C 2
where Δs is the dimensionless peak-strength multiplier, and C1,C2 are empirical parameters C1 and C2 (implemented values given below). The peak lateral strength of the infilled frame becomes the following.
The empirical strength-amplification expression uses C1 = 2.75 and C2 = 0.17, as given by Equation (3) of Cavaleri and Di Trapani [68]. In the present notation, Δs = 2.75[αs fv0/(1 MPa)]^0.17 and Fi = Δs Fb. Here, Δs denotes the dimensionless peak-strength amplification factor; Δb, Δ1, Δ2, and Δ3 denote displacements. The 1 MPa reference makes the numerical MPa convention of the empirical relation explicit. The source calibrated this relation using masonry-infilled-frame test results; it does not independently validate the strengthened-wall configurations investigated here.
F i = Δ s F b
where Fi is the maximum lateral strength of the infilled frame. The equivalent elastic modulus of masonry in the diagonal direction is computed as:
E d = ( cos 4 θ E 1 + sin 4 θ E 2 + ( sin θ cos θ ) 2 ( 1 G 12 − 2 ν 12 E 1 ) ) − 1
where Ed is the equivalent elastic modulus along the diagonal, E1,E2 are the orthotropic masonry moduli, G12 is the shear modulus, ν 12 is the Poisson ratio. The associated diagonal Poisson ratio is:
ν d = E d [ ν 12 E 1 ( sin 4 θ + cos 4 θ ) − ( 1 E 1 + 1 E 2 − 1 G 12 ) ( sin θ cos θ ) 2 ]
where ν d is the equivalent Poisson ratio along the diagonal. The empirical expressions for the geometric influence coefficients are:
c = C 3 + C 4 ν d + C 5 ν d 2 β = C 6 + C 7 ν d + C 8 ν d 2
where c , β are empirical coefficients controlling strut width, C3 … C8 are empirical parameters C3–C8 (the numerical values used in the illustrative analytical calculation are provided below). The slenderness-dependent parameter is shown as follows.
The coefficients in Equation (23) follow Equation (7) of Cavaleri and Di Trapani [68]: C3 = 0.249, C4 = −0.0116, C5 = 0.567, C6 = 0.146, C7 = −0.0073, and C8 = 0.126. Thus, c = 0.249 − 0.0116νd + 0.567νd2 and β = 0.146 − 0.0073 νd + 0.126 νd2. These dimensionless quantities describe the equivalent-strut width expression. This geometric coefficient β is distinct from the Pivot envelope stiffness-reduction parameter βC.
λ = ( E d E f ) ( th b c d c ) ( h 2 l 2 + b c d c l 4 b b d b h )
where λ is the geometry and stiffness interaction parameter, Ef is the frame elastic modulus, bb,db are beam dimensions, and bc,dc are column dimensions. The equivalent strut width is then:
w = d   k   c z   λ − β
where w is the equivalent diagonal strut width, k is the coefficient related to axial load level in columns. The diagonal strut strength is:
S 2 I = F b   ( Δ s − 1 ) sec θ
where S2I is the theoretical diagonal strut strength. A strength-modification factor is adopted as follows.
With Δs defined as a dimensionless strength multiplier, Equation (20), Fi = Δs Fb, and Equation (26), S2I = Fb(Δs − 1) sec θ, both yield force quantities. This interpretation follows the analytical implementation and does not constitute independent validation of the empirical strength relation.
Ω s = C 9 α s C 10
where Ω s is the empirical strength-modification factor, and C9,C10 are empirical parameters C9 and C10 (implemented numerical values reported below). The peak strength of the equivalent strut becomes the following.
In the illustrative analytical implementation, C9 = 0.9 and C10 = 0.26 in Equation (27), such that Ωs = 0.9αs^0.26. The same example specifies αC = 0.4, βC = 0.15, and ζC = 0.02 mm−1 for displacement measured in mm. The inverse-displacement dimension of ζC follows from the exponential form used for ultimate displacement. These example inputs should not be interpreted as independent validation of the cyclic link response in the final multi-story SAP2000 model.
S 2 = Ω s S 2 I
where S2 is the peak resistance of the equivalent diagonal strut. A yielding strength ratio defines:
S 1 = α C S 2
where S1 is the yielding strength and α C is the pivot-model material constant. A post-peak strength level is defined by:
S 3 = γ S 2
where S3 is the residual strength and γ is the symbolic degradation factor. The initial elastic stiffness is:
K 1 = E d tw d
where K1 is the initial stiffness of the equivalent strut. Post-yield stiffness is defined as:
K 2 = β C K 1
where K2 is the secondary stiffness and β C is the pivot-model stiffness-reduction coefficient. The yielding displacement:
Δ 1 = S 1 K 1
where Δ1 is the displacement at yielding. The peak displacement is shown as follows:
Δ 2 = Δ 1 + S 2 − S 1 K 2
where Δ2 is the displacement at peak strength. The ultimate displacement is shown as follows:
Δ 3 = 1 ζ C ln [ ( S 2 S 3 ) exp ( ζ C Δ 2 ) ]
The ultimate displacement in Equation (35) is obtained using the envelope-degradation parameter ζC. The S1B-1 benchmark is a planar RC portal frame with a 1.8 m span and a 1.8 m height. The active global degrees of freedom are UX, UZ, and RY. Joints 5 and 6 at the base are restrained in all six degrees of freedom. The infill is represented by two crossing axial links connecting joints 7–6 and 5–8, respectively, and sharing the corner joints with the RC frame. Both links use the nonlinear local U1 component with the Pivot hysteresis rule and a zero-force tensile branch. Automatic member-end offsets with a rigid-zone factor of 1.0 are specified. In the displacement-controlled benchmark, joint 7 has a UX restraint and an assigned ground-displacement load of 0.001 m under the lateral-load pattern; the prescribed history scales this displacement. Thus, the UX restraint is part of the imposed-displacement implementation and must not be interpreted as a stationary zero-displacement support during that load case. EQUAL2 selects UX but is assigned only to joint 8 in the two supplied infilled-frame models. It therefore does not impose equality between the lateral displacements of joints 7 and 8. These assignments describe the benchmark only and do not establish the constraints or connectivity of the global 3D models (Figure 6).
Figure 6. SAP2000 modeling configuration for S1B-1 [68].
Columns have a 200 × 200 mm square section (C20 × 20) with longitudinal reinforcement consisting of three 10 mm-diameter bars on each of the two principal faces, provided with a 50 mm clear concrete cover. Transverse confinement is achieved with 6-mm-diameter closed ties spaced at 120 mm centers throughout the column height. Beams have a 200 × 400 mm rectangular section (B20 × 40). Top and bottom longitudinal reinforcement comprises two 10-mm-diameter bars on each face, again with a 50 mm clear cover to the ties. To enhance shear resistance and confinement in the potential plastic-hinge regions, the transverse reinforcement spacing is reduced to 100 mm on center using 6-mm-diameter ties. The model uses two key material definitions that are C25 for concrete and AII for reinforcing steel, which are specified in Table 9:
Table 9. Material properties of the RC elements in the S1B-1 frame [68].
Material densities in the local wall-model table are expressed in kg/m3 (converted from kg/mm3 by multiplying by 109). For the global RC-frame properties in Table 9, stresses and elastic moduli are expressed in MPa (1 kN/mm2 = 1000 MPa). These are unit conversions only; the material quantities and numerical simulation results are unchanged.
The nonlinear behavior of the columns is captured through concentrated plasticity by assigning interacting P-M3 hinges at both ends of each column element. These hinges are placed at relative distances of 0.05 and 0.95 along the clear length of the members and are explicitly classified as deformation-controlled (ductile) elements. The plastic hinge length is taken as 20 percent of the member’s clear length. The axial-moment (P-M3) interaction surface is generated directly from ACI 318-02 provisions [70]. The moment-curvature backbone curve adopts a trilinear idealized response which is elastic perfectly plastic up to the yield moment, followed by moderate strain-hardening of 10 percent (reaching 1.1 My) at a curvature ductility of approximately 0.015, after which gradual strength degradation occurs down to a residual capacity of 0.2 My and sustains until an ultimate curvature of 0.025. Performance acceptance criteria for plastic rotation are defined as 0.003 rad for Immediate Occupancy, 0.012 rad for Life Safety, and 0.015 rad for Collapse Prevention.
The adopted Pivot settings are α1 = 0, α2 = 0.25, β1 = 0, β2 = 0, and η = 0. Cavaleri and Di Trapani [68] set the tension-related parameters to zero for their compression-only equivalent-strut idealization and report α2 = 0.25 for clay masonry in Table 6. The source value identifies a calibration precedent for the clay-infill reference; it is not a separate calibration of the four strengthened configurations. Nor does α2 = 0.25 signify a measured 25% reduction in reloading strength. A five-model cyclic comparison or sensitivity analysis is not available, so the global response remains conditional on the adopted hysteretic settings.
For the S1B-1 benchmark, both diagonal links use the same axial backbone in each model. The reference configuration assigns the Masonry property, with a peak compressive force of 25.90079 tonf (254.0 kN) at a 4.44 mm axial shortening. The present-method configuration assigns the PIVOT_NEWM property, with a peak compressive force of 23.93580 tonf (234.73 kN) at a 9.31 mm shortening and a terminal deformation of 39.94 mm. Both definitions use α1 = 0, α2 = 0.25, β1 = 0, β2 = 0, and η = 0, and specify zero force from the origin to the positive terminal tensile point. These are axial link inputs, rather than lateral frame-force results or independent cyclic-validation metrics.
The local-to-global parameter transfer concerns the yield and peak displacements, yield and peak forces, and yield-point secant stiffness of the fitted backbones. A comparison of these input quantities does not independently validate the complete SAP2000 cyclic response, unloading stiffness, or cumulative hysteretic energy. Table 10 summarizes the peak forces, peak displacements, and yield-point secant stiffnesses for the five fitted wall backbones.
Table 10. Peak force, peak displacement, and yield-point secant stiffness of the fitted wall backbones.
No independent five-model cyclic reconstruction in SAP2000 was performed; the transfer check is limited to the backbone input parameters.
The local-to-global transfer used the force–displacement backbone obtained from the ABAQUS wall analyses as the basis for defining the axial link response in SAP2000. This transfer is a parameterization procedure rather than an independent validation of the complete Pivot hysteresis law. In particular, agreement in peak backbone quantities cannot establish agreement in unloading/reloading stiffness, cyclic pinching, or accumulated dissipated energy. Because an independent overlay comparison of the complete ABAQUS and reconstructed SAP2000 cyclic loops for all five wall configurations is not available in the documented results, no numerical transfer-error percentage is claimed here. The resulting uncertainty should be considered when interpreting the global nonlinear time-history responses.
Structural mass for dynamic analyses is automatically computed from a combination of 1.0 Dead Load + 0.25 Live Load. Three principal analysis cases are defined. First, a nonlinear static gravity load case applies a total downward force of 400 kN (200 kN at each of the two top frame joints) while including geometric P-Δ effects, establishing the initial stressed state of the frame. Second, a modal analysis case using Ritz vectors is executed on the unstressed initial stiffness to extract the first three modes, achieving at least 90 percent mass participation in both horizontal directions. Finally, the seismic performance is assessed through a nonlinear direct-integration time-history analysis that continued directly from the final state of the gravity load case, thereby correctly incorporating persistent vertical loads and associated P-Δ effects throughout the lateral excitation. Lateral motion is imposed in a displacement-controlled manner by applying a displacement in the global X-direction to joint 7, subsequently scaled according to a predefined cyclic function that progressively increases the amplitude of reversed cycles (Figure 7). The analysis employes the Hilbert−Hughes−Taylor integration scheme, relies solely on hysteretic energy dissipation (no additional viscous damping), and is executed for 520-time steps with an output interval of 0.1 s.
Figure 7. Displacement-controlled loading protocol for the S1B-1 reference-frame analysis in SAP2000 (distinct from the ABAQUS wall protocol in Figure 3).
To develop a global-based 3D masonry structure that can accurately simulate both global demand parameters and damage mechanisms under nonlinear dynamic analyses, a 2-bay, four-story building model based on the study conducted by Cavaleri and Trapani is reproduced and verified in SAP2000 for this purpose. Figure 8 and Table 11 presents the 2D RC model and the characteristics of the ground motion record applied to the structure. Other modeling assumptions are similar to the S1B-1 frame and can be found in [68].
Figure 8. Applied ground motion record and element sections of the 2D RC model studied by Cavaleri and Trapani [68]. (The panels show the applied ground-motion record and the 2D RC model with element sections, respectively. Any model annotations belong to the right-hand panel.)
Table 11. Characteristics of the ground motion record used in the study of Cavaleri and Trapani [68].
The verified reference-frame modeling methodology was extended to a three-dimensional reinforced-concrete building representation in SAP2000. The compared configurations comprised the bare frame, the URM-infilled frame, and four strengthened-infill configurations. Reinforced-concrete beams and columns were represented by frame elements with concentrated plastic hinges. The global building models were fixed at their bases, with rigid diaphragm constraints assigned at floor levels.
The diagonal Pivot links representing the masonry infills were connected directly to the beam–column joints of the surrounding reinforced-concrete frames. Their axial backbone parameters were derived from the wall force–displacement responses obtained in ABAQUS.
The rigid diaphragm idealization constrains floor motion within its plane but does not independently establish the out-of-plane capacity or anchorage adequacy of the infill walls. Hospital occupancy motivates examining deformation and acceleration demands together; however, these structural simulations do not independently establish the hospital’s ability to remain operational after an earthquake.
The global-based model is subjected to nonlinear time-history analyses using the adopted case-study site and risk assumptions [71]. For this purpose, the seismic parameters such as the seismic importance factor (Ie), occupational and risk category, soil type, and parameters like R, Ω0, and Cd, representing the response modification coefficient, the overstrength factor, and the amplification factor, respectively, must be determined for the structures. For this purpose, several assumptions have been made based on the reference model and the objectives of the current study. It is assumed that the hospital is located in a location where the risk category is IV, with latitude and longitude coordinates of 37.777 and −122.42 degrees, respectively. These values define the selected high-seismicity site scenario for the present comparative numerical case study; they do not establish performance under all high-hazard locations. Based on the adopted site scenario, S1 and SS are selected 0.6597 g and 1.539 g, respectively, and based on them, SMS, SM1, SDS, and SD1 were obtained to be 1.539 g, 0.98955 g, 1.026 g, and 0.6597 g respectively. The site coefficients (Fa, Fv) became 1.0 and 1.5, respectively, to account for the influence of soil conditions on ground motion amplification (type D). The four-story 3D frame is described using a nominal 3.5 m story height, corresponding to 14.0 m over four equal stories. Seismic design coefficients, along with related parameters, are used to determine the building’s natural period and seismic response. Upper limit coefficient (Cu), time period parameter (Ct), and upper limit period (Cu˟Ct are 1.4, 0.016, and 0.0224 s, respectively, while exponent (x), short-period transition period (T0), long-period transition period (Ts), approximate fundamental period (Ta), and upper limit for T were 0.9, 0.128, 0.643, 0.53, and 0.747 s, respectively, which define the expected range for the building’s natural vibration period and its influence on seismic response. Seismic response coefficient (Cs) depends on the building’s natural period in relation to the long-period transition period (TL, set at 8 s in this case). The calculated Cs (0.265) exceeds the minimum limit (0.0677).
The global-based models are then subjected to near- and far-field earthquakes in SAP2000 and analyzed using the nonlinear dynamic time-history method. The selected records are discussed with reference to FEMA P695 and the ASCE 7-16 response-history framework; the six-pair case-study set is not presented as code-compliant [71,72]. Records are derived from FEMA P695 that suggests ground motions, particularly those with pulse-like characteristics. These records are then extracted from the Pacific Earthquake Engineering Research Center Next Generation Attenuation (PEER-NGA) database. Each record consists of two horizontal components, with their magnitudes ranging from 6.69 to 6.9. The peak ground acceleration (PGA) values vary from 0.08 g to 0.43 g. Table 12 presents a summary of seismic parameters for the near- and far-field ground motion records selected from the PEER-NGA database. The acceleration time history records for near- and far-field earthquake records are also shown in Figure 9 to Figure 10, respectively.
Table 12. Summary of seismic parameters for the near- and far-field ground motion records selected from the PEER-NGA database.
Figure 9. Acceleration time history record for near-field earthquake records.
Figure 10. Acceleration time history record for far-field earthquake records.
In Table 13 and Table 14, “Number of input data points” denotes the number of sampled acceleration ordinates for each record component; it is not an indication that the nonlinear analysis produced no output. The reported scaling factors are the values applied to the selected records, and the six-record set is treated as a case-study comparison rather than a code-compliant eleven-pair suite.
Table 13. Detailed scaling and temporal inputs for the near-field earthquake records in nonlinear dynamic time-history analysis.
Table 14. Detailed scaling and temporal inputs for the far-field earthquake records in nonlinear dynamic time-history analysis.
Interpretation of the record set: The six-record suite provides comparisons within the investigated structural configuration and chosen motions, rather than a statistically representative basis for code-design acceptance or a quantified collapse-risk estimate. Results should be interpreted record by record; no additional time-history analyses or independent spectrum-matching verification are claimed in this revision.
Ground-motion suite limitation and scaling interpretation: The study employs three near-field and three far-field two-component record pairs for a comparative numerical case study. This limited suite is not presented as satisfying the minimum eleven-pair requirement cited for ASCE 7-16 nonlinear response-history assessment. The reported first-stage factors include SF1 = 11.905 for F_LOMAP_SUF and SF1 = 6.803 for F_NORTHR_LV5; such substantial amplitude adjustments warrant caution because scaling changes intensity but does not remove record-specific spectral characteristics. The second-stage factor is reported as SF2 = 0.5, so the applied factor is SF = SF1 × SF2. These records and factors are retained as originally analyzed; no additional record selection, spectral matching, or sensitivity analysis is claimed here. Accordingly, the near-field/far-field comparisons are descriptive of this selected record set and should not be interpreted as a statistically general or code-compliant seismic assessment.
The six selected ground-motion pairs were processed using SeismoSignal. Each record pair undergoes normalization where the PGA reaches 1.0 g through an initial scaling factor (SF1). This process establishes consistent PGA values across all records. Response spectra for each record pair are calculated through dynamic structural equations, incorporating a 5 percent damping ratio as required by the research parameters. The Square Root of the Sum of Squares method (SRSS) combines these spectra, producing a single unified spectrum for each pair. After averaging these combined spectra, a second scaling factor (SF2) is applied to match the averaged spectrum with standard design requirements. The raw ground motion records imported into SAP2000 are multiplied by SF2 × SF1 = SF, representing the complete scaling process and achieving the target intensity level. In this study, PGA serves as the intensity measure, capturing the essential seismic characteristics of each motion. The averaged response spectrum is compared with the design target over the 0.2T–1.5T period range; the available input data do not independently establish compliance with a particular ASCE spectral-matching requirement (Figure 11). Table 13 and Table 14 present scaling calculations and temporal inputs for the near- and far-field earthquake records in nonlinear dynamic time-history analysis.
Figure 11. Comparison of the 5% damped average response spectra with the target design spectrum for the near-field and far-field earthquake suites.

3. Results

This section reports the cyclic numerical responses of the ABAQUS wall models and the corresponding backbone-based Pivot representations used for subsequent SAP2000 global analyses. The four strengthening configurations (tie rods, BFRP strips, SFRC overlays, and UHPC overlays) exhibit different simulated mechanical responses. The unstrengthened reference model has been compared with experimental evidence, whereas independent cyclic experimental validation of the four strengthened models and a full ABAQUS-versus-Pivot hysteresis-loop verification have not been established.
Figure 12 displays the load−displacement response of the URM wall including the comparison of hysteresis curves obtained from FE modeling in ABAQUS with the experimental hysteresis curve. As shown in Figure 12, the comparison with the CL-05 benchmark provides a case-specific check of the unstrengthened-wall force–displacement response; it does not establish independent validation of the four strengthened models, their interface laws, or transferred SAP2000 hysteresis. The DSS failure of CL-05 and the tensile damage of the FE model are shown in Figure 13.
Figure 12. Hysteresis curves obtained from the FE modeling in ABAQUS and the experimental hysteresis curve.
Figure 13. DSS failure of CL-05 and the tensile damage of the FE model.
The hysteretic performance and Pivot constitutive parameters are presented in Figure 14, Figure 15, Figure 16, Figure 17 and Figure 18 for the base model (URM) and the rehabilitated models using the tie-rod system, FRP strips, SFRC, and UHPC coating under cyclic loading. Mechanical response and Pivot parameters of all local models are summarized in Table 15, which will be used later in SAP2000.
Figure 14. FE 3D mesh configuration, tensile contour plot, hysteretic envelope curve, and Pivot curve of the base model.
Figure 15. FE 3D mesh configuration, tensile contour plot, hysteretic envelope curve, and Pivot curve of the tie-rod model.
Figure 16. FE 3D mesh configuration, tensile contour plot, hysteretic envelope curve, and Pivot curve of the FRP model.
Figure 17. FE 3D mesh configuration, tensile contour plot, hysteretic envelope curve, and Pivot curve of the SFRC model.
Figure 18. FE 3D mesh configuration, tensile contour plot, hysteretic envelope curve, and Pivot curve of the UHPC model.
Table 15. Mechanical response and Pivot parameters of the local models.
Figure 14 presents the FE 3D mesh configuration, tensile contour plot, hysteretic envelope curve, and Pivot curve of the base model. The base model exhibited tensile cracking in a form of sliding shear along diagonal stepped cracks (DSS) as well as progressive stiffness degradation under cyclic loading. The base model (URM) reached a yield strength of 659 kN, a peak strength of 734 kN, and had cumulative work of 103,178.06 kN·mm along the recorded loading path. Its ultimate tensile displacement (30.45 mm) was comparable to that of the strengthened models.
The tensile damage on the tie-rod-rehabilitated wall under cyclic loading is shown in Figure 15, demonstrating reduced damage compared to the base model due to effective load redistribution by the tie rods. The tie-rod system considerably improved strength compared with the base wall. The yield strength increased by 5.19 percent, and peak strength rose by up to 38.15 percent. The residual (ultimate) compression force also improved substantially by up to 352 percent, indicating enhanced post-peak stability. Displacement capacity was also extended and the yield displacement increased from 0.056 mm to 1.30 mm, while peak displacement grew from 2.17 mm to 3.51 mm, reflecting delayed yielding and improved deformation tolerance. Cumulative work along the recorded path increased by 57.62 percent. Although the yield-point secant stiffness was lower (533 kN/mm vs. 11,878 kN/mm in the base), the tie rod maintained relatively high post-yield stiffness and showed gradual softening (K3 = −10.53 kN/mm), which confirms a more ductile response than the base model.
Figure 16 depicts the tensile damage on the FRP-rehabilitated wall under cyclic loading, revealing localized damage mitigation through the FRP’s bridging effect, without simulating strip rupture or interface debonding. The simulated masonry damage contours show localized concentrations near the crossing of the diagonal BFRP strips; the linearly elastic BFRP model contains no independent strip-fracture or interface-debonding criterion, so such failures cannot be inferred. The use of the strip effectively reduced the amount of tensile damage in the wall. FRP strips improved strength moderately but less effectively than tie rods. The yield strength slightly decreased by 4.72 percent, but the peak strength increased by up to 29.37 percent. The ultimate compression force improved from 157 kN (base) to 444 kN, providing better residual capacity. The deformation capacity was enhanced, with yield displacement increasing to 1.16 mm and peak displacement increasing to 3.67 mm. Cumulative work along the recorded path was 16.72 percent higher than for URM but lower than for the tie-rod, SFRC and UHPC configurations. In terms of stiffness, FRP showed similar trends to the tie-rod system, with low yield-point secant stiffness (542 kN/mm) and moderate post-yield stiffness (128 kN/mm). The descending stiffness (−18.85 kN/mm) indicates a brittle-softening tendency, although the behavior is less severe than that observed with UHPC or SFRC coating.
Figure 17 shows the tensile damage on the wall and SFRC layers under cyclic loading, demonstrating excellent crack control and reduced damage propagation due to fiber reinforcement. SFRC coating significantly enhanced both strength and ductility.
The yield strength rose by up to 79.2 percent and the peak strength rose by up to 83.33 percent, both higher than the base model. However, the ultimate compression force remained moderate (200 kN), indicating post-peak softening. The yield displacement increased to 0.073 mm and peak displacement reached 3.63 mm. SFRC exhibited the highest cumulative work along the recorded wall-level path (232,400.58 kN·mm), compared with 103,178.06 kN·mm for URM, an increase of 125.24%. Its yield-point secant stiffness K1 (16,203 kN/mm) was high within the compared configurations; the post-yield stiffness was 46 kN/mm and the descending stiffness was −42.57 kN/mm. These comparisons are conditional on the investigated loading paths and modeling assumptions and do not establish general superiority.
Figure 18 shows the tensile damage on the wall and UHPC layers under cyclic loading, with minimal damage owing to UHPC’s high tensile strength and toughness. UHPC coating provided the greatest improvement in strength but at the expense of ductility. The yield and peak strengths increased by 88.49 and 125.62 percent, respectively, the highest of all strengthening methods. The ultimate compression force improved modestly to 220 kN compared to the base model, but lower than the tie-rod and FRP systems. Relative to the URM wall, the yield displacement increased from 0.056 to 0.073 mm, while the displacement at peak force decreased from 2.17 to 1.59 mm. The UHPC model also reached peak force at a smaller displacement than the SFRC, BFRP, and tie-rod models. In terms of stiffness, UHPC achieved the highest yield-point secant stiffness (17,031 kN/mm) and post-yield stiffness (271 kN/mm), delaying deformation most effectively. However, its descending stiffness (−49.66 kN/mm) was the steepest, confirming sudden post-peak strength loss. Cumulative work along the recorded path was 57.43 percent higher than for URM, comparable to tie rods and lower than for SFRC.
As noted in Table 15, K1 = Syc/dyc denotes the yield-point secant stiffness and is distinct from the initial equivalent-strut stiffness K1 in Equation (31). Sut = 0 is prescribed in the backbone-generation procedure, giving a zero-force tensile branch between the origin and the terminal tensile point; it is a modeling assumption, not a measured tensile strength of the wall or strengthening material. Wpath is the unscaled signed cumulative work along the recorded force–displacement path, not an isolated measure of closed-loop dissipation.
Cumulative work along the recorded path. The wall-level quantity is evaluated as Wpath = Σ[(Fi + Fi+1)/2](Δi+1 − Δi), using the recorded point order, displacement represented in mm, and force represented in kN. The force sign is reversed relative to the reported reaction, and N is converted to kN. The 121 available points per configuration are integrated without sorting, taking absolute increments, or dividing by four. The resulting values in Table 15 supersede the quarter-scaled values. The paths start at the origin but end at nonzero displacement and force; no artificial closing segment is added. Wpath therefore denotes the signed net external work over the available loading path, which can include a change in stored energy, rather than an independently isolated closed-loop dissipated energy. The same scaling correction leaves the relative comparisons unchanged.
Figure 19 compares the five fitted Pivot backbones derived from the ABAQUS wall analyses and used as parameter inputs in the SAP2000 global representations. Across the five wall configurations, the prescribed ultimate tensile deformation parameter (dut) ranges from 30.45 to 32.23 mm, whereas the terminal tensile strength (Sut) is zero in each fitted backbone. Table 15 gives the other yield, peak, post-peak, and stiffness parameters. These plots document the fitted input backbones and do not constitute an independent comparison of full cyclic unloading and reloading histories from SAP2000.
Figure 19. Comparison of Pivot curves for the local models.
Before applying the rehabilitation methods to the full 3D structure, the modeling framework required validation at both the component and system levels to ensure accuracy in predicting cyclic behavior and global seismic response. The validation process proceeded in two stages: first comparing analytical and FE predictions against experimental tests of infilled frames, and then verifying the global model’s ability to reproduce benchmark dynamic analyses including roof displacements and accelerations, inter-story drifts, base shear demands and plastic hinge distributions.
For the S1B-1 URM reference case, the analytical/Pivot-based representation was compared with the quasi-static experimental results reported by Cavaleri and Trapani (Figure 20). The reported ultimate displacement from the analytical method (39.96 mm) is close to the experimental value (40.0 mm); the reported predicted peak force is 221.65 kN. This reference-case comparison supports the selected modeling approach for the unstrengthened benchmark, but it does not demonstrate independent agreement of unloading stiffness, reloading paths, or cumulative hysteretic energy for all five ABAQUS-derived wall configurations. Therefore, it should not be interpreted as a five-model validation of the local-to-global Pivot transfer.
Figure 20. S1B-1 reference-case cyclic load–displacement comparison. Upper panels compare the reported Cavaleri and Di Trapani [68] response with the reproduced curves; lower panel: black is the reference hysteretic response and red is the analytical Pivot backbone.
The second-stage results showed that under the applied ground motion record, the maximum base shear obtained from the present study was 354.52 kN, compared to 378.42 kN reported in the reference model, corresponding to a deviation of approximately 6.3 percent. The peak base-shear difference is approximately 6.3% for this selected validation case (Figure 21); this single-metric agreement is not a comprehensive verification of global cyclic response, mass distribution, or all modal properties.
Figure 21. Base-shear time histories for the reference bare frame and URM-infilled frame, including the reproduced URM-infilled response from the present study (see image legend).
Further validation was achieved by comparing the plastic hinge formation patterns. The reproduced model captured the spatial distribution and sequence of hinge formation reported in the benchmark study, with similar proportions of elements reaching immediate occupancy, life safety, and collapse prevention performance levels. These results confirm that the proposed global-based modeling framework is capable of accurately simulating both global demand parameters and damage mechanisms in structural systems subjected to seismic loading (Figure 22).
Figure 22. Comparison of plastic hinge formation status of the reproduced 2D RC frame with Cavaleri and Trapani’s model. The left panel shows the reference model and the right panel shows the reproduced model.
The 2D RC model was expanded into a 3D RC structure in SAP2000, with URM infill walls and rehabilitated models applied to designated frames using the Pivot model. All bays maintained consistent dimensions matching the five models previously analyzed in ABAQUS (the tie-rod, FRP, SFRC, and UHPC unit walls). A bare frame was included to quantify the influence of masonry infills; comparisons among strengthening strategies instead use the same-record URM-infilled frame as their primary reference. Infill walls were incorporated in the perimeter frames to accommodate openings and ensure result comparability (Figure 23).
Figure 23. SAP2000 three-dimensional global frame configurations: bare frame, URM-infilled reference, and strengthened infill alternatives.
Table 16 and Figure 24 report the maximum inter-story drift ratios for the six global configurations under six earthquake records. The bare frame reached 1.30–2.83%, compared with 0.08–0.22% for the unstrengthened URM-infilled frame, a record-wise reduction of 90.8–96.1% relative to the bare frame. With the URM-infilled frame as the reference for each matching record, the tie-rod configuration increased peak drift by 71.4–227.8%, and BFRP increased it by 87.5–236.4%. Conversely, SFRC reduced peak drift by 27.8–50.0%, and UHPC reduced peak drift by 33.3–59.1%, relative to the same URM-infilled reference. The observed drift ranges were 0.14–0.59% (tie rods), 0.15–0.74% (BFRP), 0.04–0.13% (SFRC), and 0.04–0.12% (UHPC). All values are the maximum inter-story drift ratios from the adopted models; no residual-drift or post-earthquake functionality inference is made. These comparisons are record-specific and do not demonstrate an intrinsic near-field or far-field superiority.
Table 16. Summary of the maximum inter-story drift across the global models under near- and far-field earthquakes.
Figure 24. Clustered bar, radar chart, and lateral drift profiles illustrating comparative maximum inter-story drift across global models under near- and far-field earthquakes.
Table 17 and Figure 25 present peak base shear demands under the six selected records. The bare-frame base shear ranged from 4819.92 to 7303.55 kN, whereas the URM-infilled reference ranged from 6398.81 to 14,672.10 kN. Comparing the same record and configuration, adding the URM infill increased the peak base shear by 32.8–100.9% relative to the bare frame. Relative to the URM-infilled frame, tie-rod base shear changes ranged from a 30.1% reduction to a 5.9% increase, and BFRP base shear changes range from a 32.9% reduction to a 4.4% increase. SFRC ranged from a 0.5% reduction to a 6.0% increase, and UHPC increased by 0.9–6.1%. Thus, neither tie rods nor BFRP consistently reduced peak base shear for every record, and SFRC did not invariably increase it. The far-field F_NORTHR_LV5 record produced the largest peak base shear in all six configurations; the results do not support a general claim that near-field records generate 18–38% higher base shear. Increased shear demand in some stiffened configurations should be considered when assessing existing members and foundations, but foundation capacity was not directly evaluated here.
Table 17. Peak base shear demands of the global models under near- and far-field earthquakes.
Figure 25. Clustered-bar and radar-chart comparison of peak base-shear demand under near-field and far-field records.
Table 18 and Figure 26 present peak roof accelerations for the six global models. The bare-frame accelerations ranged from 2400.82 to 5621.43 mm/s2 and the URM-infilled reference from 2246.56 to 11,341.68 mm/s2. Comparing each configuration with the URM-infilled frame under the same record, tie-rod acceleration changed from an 11.9% reduction to a 74.8% increase, and BFRP acceleration changed from an 18.4% reduction to a 73.5% increase. SFRC changed from a 12.0% reduction to a 10.5% increase, whereas UHPC changed from a 9.7% reduction to a 14.2% increase. The highest peak roof acceleration (12,217.46 mm/s2) occurred for UHPC under F_NORTHR_LV5. The acceleration trade-off therefore depends on both the configuration and record; no strengthening scheme consistently reduced roof acceleration across the six selected records.
Table 18. Peak roof acceleration demands of the global models under near- and far-field earthquakes (mm/s2).
Figure 26. Clustered-bar and radar-chart comparison of peak roof acceleration under near-field and far-field records.
Table 19 and Figure 27 summarize peak roof displacements under the six ground-motion records. The bare frame reached 162.11–367.69 mm, compared with 7.50–20.60 mm for the URM-infilled reference, corresponding to record-wise reductions of 92.3–97.2%. Relative to the same-record URM reference, the tie-rod model increased roof displacement by 71.0–231.5%, and the BFRP model increased it by 86.8–238.6%. SFRC reduced roof displacement by 29.1–53.7%, while UHPC reduced it by 29.7–59.8%. The corresponding modeled displacement ranges are 14.00–51.09 mm (tie rods), 14.83–69.75 mm (BFRP), 4.44–10.90 mm (SFRC), and 4.32–10.80 mm (UHPC). The percentage ranges were calculated record by record against the URM-infilled reference, rather than by comparing independent maxima or minima from different records.
Table 19. Peak roof displacement demands of the global models under near- and far-field earthquakes (mm).
Figure 27. Clustered bar and radar chart illustrating comparative peak roof displacement across global models under near- and far-field earthquakes.
Table 20 reports the distribution of 640 plastic hinges per structural configuration and ground-motion record, classified into A–IO, IO–LS, LS–CP, and >CP response ranges. The counts were checked against the SAP2000 export. The occurrence of hinges exceeding CP is record- and configuration-dependent. For example, under F_LOMAP_SUF, two bare-frame hinges exceed CP, compared with zero for URM, tie-rod, and FRP frames and one each for SFRC and UHPC frames. These hinge-state counts describe local member response classifications and do not, on their own, establish global collapse prevention. For the F_LOMAP_SUF record, the corresponding proportions of hinges exceeding CP are 0.3125% for the bare frame (2/640), 0% for the URM, tie-rod and FRP configurations, and 0.15625% for each of the SFRC and UHPC configurations (1/640). These small percentages describe hinge counts and must not be interpreted as a direct probability of structural collapse. Figure 28 compares the percentage distributions of the four hinge states across the six configurations and six records.
Table 20. Number of plastic hinge formation for the global models under near- and far-field earthquakes.
Figure 28. Percentage distribution of plastic-hinge states for the six frame configurations and six ground-motion records, reconstructed from the counts in Table 20. Percentages equal 100× count/640 for each category, record, and configuration; the four categories sum to 100% (subject to rounding).

4. Discussion

The preceding section presents wall-level cyclic numerical results, transferred Pivot backbone parameters, and frame-level seismic response quantities. This section interprets their differences for the selected frame and strengthening configurations, distinguishes model predictions from experimental evidence and identifies the engineering limitations relevant to the six selected ground-motion records.

4.1. Interpretation of Wall-Level Response

The wall-level calculations show a trade-off between strength, the fitted yield-point secant stiffness, and post-peak deformation. The tie-rod and BFRP configurations exhibit larger identified yield displacements and lower values of K1 than the URM reference, whereas SFRC and UHPC produce larger peak resistance but comparatively steep descending branches in the adopted idealizations (Table 15 and Figure 19). Because K1 = Syc/dyc, it must not be equated with an independently measured initial tangent modulus.
The SFRC wall-level cumulative path work is 232,400.58 kN·mm, compared with 103,178.06 kN·mm for URM, an increase of 125.24%. These values use the unscaled trapezoidal integral of the recorded force–displacement history. Because the records terminate at nonzero force and displacement, this measure is net work over the available path and is not independently separated into dissipated and stored energy. The assumed fully bonded BFRP interface and elastic strips cannot predict strip rupture or bond separation, and the transferred Pivot inputs are not independent cyclic-loop validation.

4.2. Global Response Trade-Offs

The percentages reported for global response depend on the individual ground-motion record and the selected reference model. A comparison with the bare RC frame is not interchangeable with a comparison against the URM-infilled frame. The tabulated results in Table 16, Table 17, Table 18 and Table 19 provide the record-matched basis for the percentage ranges used in the abstract, discussion, and conclusions.
For the adopted model and selected earthquake records, SFRC and UHPC overlays resulted in the lowest calculated roof displacement demands, with the maximum modeled displacements of 10.90 mm and 10.80 mm, respectively. By contrast, tie-rod and BFRP configurations produced higher peak displacements than the URM-infilled reference in every selected record. Although these patterns are consistent with differences in the assumed wall-level force–displacement responses, the present analysis does not independently establish that perfect composite action persists, that separation is prevented, or that post-event serviceability is ensured.
Lower drift and displacement demand does not necessarily imply lower acceleration demand for acceleration-sensitive components. The adopted SAP2000 analyses show record-dependent acceleration increases for both SFRC and UHPC relative to the URM-infilled reference, including increases of up to 10.5% and 14.2%, respectively. Although changes in global stiffness and vibration characteristics may contribute, separate analyses isolating natural-period shifts, damping contributions, or nonstructural damage were not conducted; these mechanisms and consequences should not be asserted as verified findings.
The hinge results suggest that the presence and strengthening of infill walls can redistribute inelastic demands. The patterns are record-dependent and should not be interpreted as proof of global collapse prevention or universal superiority of any strengthening system.
Reduced deformation demand should therefore be considered alongside force and acceleration demand, rather than used alone to rank strengthening techniques. The six motions form a limited comparative sample and do not demonstrate that any technique minimizes every response measure under every earthquake. The hinge states in Table 20 likewise describe numerical member-demand categories, not a direct collapse probability or proof of post-earthquake operability.

4.3. Assumptions, Limitations, and Practical Applicability

The global seismic assessment was performed using the structural configurations investigated in this work and three near-field and three far-field ground-motion record pairs. These records provide a comparative basis but do not establish statistical robustness or full code-based ground-motion-suite compliance. Each strengthening strategy was evaluated using a specific configuration; variations in overlay thickness, fiber-strip layout, tie-rod arrangement, material properties, and interface behavior were not systematically studied. The local-to-global transfer also relies on constitutive and hysteretic modeling assumptions for which comprehensive sensitivity studies and independent strengthened-wall experimental validation were not performed. Accordingly, the conclusions apply to the adopted models and should not be treated as universal design recommendations.
Evidence boundary for validation. The CL-05 comparison assesses the unstrengthened reference-wall response only. No independently measured cyclic response histories for each strengthened-wall configuration, controlled mesh-refinement sequence, interface-slip sensitivity study, or independent matched ABAQUS–SAP2000 Pivot-loop overlay are reported. Consequently, the study presents conditional numerical comparisons rather than broadly validated performance predictions for real buildings.
Foundation-demand and soil–structure interaction limitation. The higher base-shear demands reported for the stiffer SFRC- and UHPC-strengthened configurations indicate that drift reduction does not necessarily imply reduced force demand on the existing foundation. The global models do not provide a separate foundation-capacity check or an explicit soil–structure interaction analysis. Consequently, foundation adequacy, potential uplift or settlement, and the need for foundation strengthening cannot be established from the present results. These issues require project-specific assessment before applying the investigated retrofitting strategies in practice. The global SAP2000 models adopted a fixed-base assumption; foundation flexibility and soil–structure interaction were not considered.
In-plane/out-of-plane interaction and anchorage limitation. The numerical wall models were developed to assess in-plane lateral response. Out-of-plane instability, combined in-plane/out-of-plane loading, and potential loss of wall-to-frame anchorage were not independently simulated. Consequently, the reported benefits of BFRP, SFRC, and UHPC strengthening cannot be interpreted as demonstrated improvements in out-of-plane capacity or post-earthquake retention of infill panels. The adequacy of wall anchorage and diaphragm load transfer must be evaluated separately before the findings are applied to an existing building.

5. Conclusions

This study developed an integrated analytical and numerical workflow for assessing unreinforced masonry (URM) infills and four rehabilitation strategies in a reinforced-concrete frame. Local wall responses were simulated in ABAQUS and used to define Pivot-model inputs for subsequent SAP2000 global analyses under six selected ground-motion records. Experimental comparison was available for the unstrengthened reference wall only; the strengthened-wall responses and the ABAQUS-to-Pivot transfer have not been independently validated against cyclic tests.
  • Validation of the unstrengthened reference wall was conducted against the CL-05 experimental benchmark. This comparison supports the adopted ABAQUS modeling approach for the URM reference configuration but does not constitute independent experimental validation of the four strengthened-wall configurations. In particular, separate cyclic experimental comparisons for tie-rod, BFRP, SFRC, and UHPC strengthening, and an independent quantitative assessment of the ABAQUS-to-Pivot hysteretic transfer error, have not been established in the available study records. The corresponding predictions should therefore be interpreted as numerical comparisons subject to the stated modeling assumptions.
  • At the local level, all rehabilitation methods altered the failure mechanism and hysteretic response of the masonry wall. Tie-rod and FRP systems primarily enhanced deformation capacity and post-yield stability through load redistribution and crack-bridging effects, while cement-based solutions substantially increased strength and stiffness. UHPC coatings provided the highest gains in peak compressive resistance and yield-point secant stiffness but exhibited pronounced post-peak softening. In contrast, SFRC coatings achieved a favorable combination of strength enhancement, ductility improvement, and the largest cumulative work calculated from the recorded wall-level force−displacement history among the selected cases; independent failure-mode and cyclic validations remain limited.
  • Relative to the bare frame, the inclusion of URM infill walls reduced peak inter-story drifts by 90.8–96.1% and roof displacements by 92.3–97.2% across the six selected records. Using the URM-infilled configuration as the same-record reference, SFRC and UHPC reduced maximum inter-story drift by 27.8–50.0% and 33.3–59.1%, respectively, and reduced peak roof displacement by 29.1–53.7% and 29.7–59.8%, respectively. Tie rods and BFRP increased both metrics compared with the URM reference for all six records. These are numerical model predictions, not estimates of post-earthquake residual deformation.
  • Relative to the same-record URM-infilled reference, tie-rod peak base shear ranged from 30.1% lower to 5.9% higher and BFRP peak base shear from 32.9% lower to 4.4% higher. SFRC ranged from 0.5% lower to 6.0% higher, and UHPC was 0.9–6.1% higher. Therefore, the base-shear response cannot be described as uniformly reduced for the tie-rod/BFRP models or uniformly increased for SFRC. As foundation and member resistance were not explicitly checked, potential force-demand increases remain a practical design limitation.
  • The peak roof-acceleration changes relative to the same-record URM-infilled reference were −12.0% to +10.5% for SFRC and −9.7% to +14.2% for UHPC. Thus, their modeled improvements in drift and displacement occur with record-dependent acceleration trade-offs; possible consequences for acceleration-sensitive nonstructural components require further study. Individual changes in modal period and damping were not isolated in these analyses.
  • The plastic-hinge classifications in Table 20 indicate differences in modeled inelastic demand among the six frame configurations. In several record–model combinations, SFRC and UHPC exhibited fewer hinges in the most severe reported states than the bare frame. These results describe the adopted SAP2000 hinge model and selected records; they do not by themselves establish superior collapse safety or post-earthquake functionality.
  • For the six selected records, differences between near-field and far-field responses varied by structural configuration and response metric. The limited record set and differing scaling factors do not support a general conclusion that SFRC or UHPC systems are intrinsically less sensitive to near-field pulse effects. A broader, consistently scaled record suite and explicit pulse-characterization study would be required to test that hypothesis.
Within the investigated two-bay, four-story reinforced-concrete frame with the selected masonry infill arrangement and six earthquake records, SFRC and UHPC overlays provided substantial reductions in displacement and drift demands relative to the unstrengthened infilled configuration, while also influencing base-shear and floor-acceleration demands. SFRC showed the highest cumulative work calculated from the recorded wall-level force−displacement history among the investigated configurations. These findings do not establish universal superiority or post-earthquake hospital functionality: foundation capacity, nonstructural acceleration-sensitive components, construction cost, interface debonding, out-of-plane response, and soil–structure interaction were not comprehensively evaluated. The conclusions are specific to the adopted frame, wall properties, strengthening configurations, and ground-motion set. Further studies should investigate different opening ratios, masonry strengths, building heights, near-field pulse characteristics, interface laws, soil–structure interaction, and independent cyclic validation of the strengthened-wall and Pivot representations.

Author Contributions

Conceptualization, F.S.A. and S.A.Z.; methodology, F.S.A. and S.A.Z.; software, F.S.A. and S.A.Z.; validation, S.A.Z. and F.S.A.; formal analysis, S.A.Z., H.K.S., and M.S.B.; investigation, S.A.Z., H.K.S., and M.S.B.; resources, F.S.A. and S.A.Z.; data curation, F.S.A.; writing of the original draft preparation, F.S.A., S.A.Z., H.K.S., and M.S.B.; writing review and editing, F.S.A., S.A.Z., H.K.S., and M.S.B.; supervision, S.A.Z., H.K.S., and M.S.B.; project administration, S.A.Z., H.K.S., and M.S.B.; funding acquisition, F.S.A. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Data Availability Statement

The authors declare that the data supporting the findings of this study are available within the paper.

Conflicts of Interest

The authors declare no conflicts of interest.

Nomenclature

SymbolDescription
αCPivot-model yielding parameter
αsmasonry-to-frame strength ratio
βCPivot-model stiffness reduction coefficient
bb, dbbeam width and depth, respectively
bc, dccolumn width and depth, respectively
c, βempirical coefficients controlling strut width, respectively
dmasonry diagonal length
Δ1yielding displacement
Δ2peak displacement
Δ3ultimate displacement
Δblateral displacement of bare frame
Δsdimensionless peak-strength amplification factor
E1, E2masonry elastic moduli in principal directions
Edequivalent diagonal elastic modulus
Efframe elastic modulus
Fblateral load on bare frame
Fipeak lateral strength of infilled frame
Fwdiagonal compression strength of infill
fv0masonry shear/compression strength parameter
G12masonry shear modulus
hframe height (axis-to-axis)
hnnet frame height
kcoefficient related to axial load on columns
kbbare frame lateral stiffness
K1initial stiffness of the equivalent strut
K2secondary (post-yield) stiffness
lframe length (axis-to-axis)
lnnet frame length
Muultimate moment of columns
ν12masonry Poisson ratio
νdequivalent diagonal Poisson ratio
Ωsstrength modification factor
S1yielding strength of strut
S2peak strength of equivalent strut
S2Iinitial theoretical diagonal strut strength
S3post-peak residual strength
tmasonry infill thickness
wequivalent strut width
zframe aspect ratio (l/h)
ζCPivot-model degradation parameter
λslenderness interaction parameter
θinfill diagonal inclination angle

References

  1. Garcia Ramonda, L. Seismic Retrofit of Masonry with Innovative Materials for Strengthening and Repair; Barcelona Tech: Barcelona, Spain, 2020. [Google Scholar]
  2. ASCE/SEI41-06; Seismic Rehabilitation of Existing Buildings. ASCE: Reston, VA, USA, 2007.
  3. Krimgold, F. Incremental Seismic Rehabilitation of Hospital Buildings: Providing Protection to People and Buildings; Federal Emergency Management Agency: Washington, DC, USA, 2003.
  4. Cuhadaroglu, S.P.; Akpinar, E.; Okay, F.; Atalay, H.M.; Ozden, S. Analytical, Numerical and Experimental Studies on Stability of Three-Segment Compression Members with Pinned Ends. In Advances in Computational Stability Analysis; IntechOpen: London, UK, 2012. [Google Scholar]
  5. Borah, B.; Singhal, V.; Kaushik, H.B. Sustainable housing using confined masonry buildings. SN Appl. Sci. 2019, 1, 983. [Google Scholar] [CrossRef] [Scilit]
  6. Cardoso, R.; Lopes, M.; Bento, R. Seismic evaluation of old masonry buildings. Part I: Method description and application to a case-study. Eng. Struct. 2005, 27, 2024–2035. [Google Scholar] [CrossRef] [Scilit]
  7. Abrams, D.P. Performance-based engineering concepts for unreinforced masonry building structures. Prog. Struct. Eng. Mater. 2001, 3, 48–56. [Google Scholar] [CrossRef] [Scilit]
  8. Chuang, S.-W.; Zhuge, Y.; McBean, P. Seismic Retrofitting of Unreinforced Masonry Walls by Cable System; University of Newcastle: Callaghan, NSW, Australia, 2004. [Google Scholar]
  9. Sathiparan, N.; Sakurai, K.; Numada, M.; Meguro, K. Seismic evaluation of earthquake resistance and retrofitting measures for two story masonry houses. Bull. Earthq. Eng. 2014, 12, 1805–1826. [Google Scholar] [CrossRef] [Scilit]
  10. Lourenço, P.B. Computational Strategies for Masonry Structures: Multi-Scale Modeling, Dynamics, Engineering Applications and Other Challenges; Spanish Society for Numerical Methods in Engineering (SEMNI): Bilbao, Spain, 2013. [Google Scholar]
  11. Pasticier, L.; Amadio, C.; Fragiacomo, M. Non-linear seismic analysis and vulnerability evaluation of a masonry building by means of the SAP2000 V. 10 code. Earthq. Eng. Struct. Dyn. 2008, 37, 467–485. [Google Scholar] [CrossRef] [Scilit]
  12. Salonikios, T.; Karakostas, C.; Lekidis, V.; Anthoine, A. Comparative inelastic pushover analysis of masonry frames. Eng. Struct. 2003, 25, 1515–1523. [Google Scholar] [CrossRef] [Scilit]
  13. Sweeney, S.C.; Horney, M.A.; Orton, S.L. Tri-Directional Seismic Analysis of an Unreinforced Masonry Building with Flexible Diaphragms; U.S. Army Engineer Research and Development Center, Construction Engineering Research Laboratory: Champaign, IL, USA, 2004.
  14. Turk, A.M.; Cosgun, C. Seismic behaviour and retrofit of historic masonry minaret. Građevinar 2012, 64, 39–45. [Google Scholar] [CrossRef] [Scilit]
  15. Hancilar, U.; Çaktı, E.; Erdik, M. Earthquake performance assessment and rehabilitation of two historical unreinforced masonry buildings. Bull. Earthq. Eng. 2012, 10, 307–330. [Google Scholar] [CrossRef] [Scilit]
  16. Mustafaraj, E.; Yardım, Y. Repair and strengthening of historical structures: Naziresha’s Mosque in Elbasan. In Proceedings of the 3rd Annual International Conference on Civil Engineering; Athens Institute for Education and Research (ATINER): Athens, Greece, 2013. [Google Scholar]
  17. Fathalla, E.; Salem, H. Parametric study on seismic rehabilitation of masonry buildings using FRP based upon 3D non-linear dynamic analysis. Buildings 2018, 8, 124. [Google Scholar] [CrossRef] [Scilit]
  18. Zhang, S.; Yang, D.; Sheng, Y.; Garrity, S.W.; Xu, L. Numerical modelling of FRP-reinforced masonry walls under in-plane seismic loading. Constr. Build. Mater. 2017, 134, 649–663. [Google Scholar] [CrossRef] [Scilit]
  19. Buljubašić, E.; Simonović, G. Analysis of masonry walls strengthened with mechanical dampers. E-Zb. Elektron. Zb. Rad. Građev. Fak. 2019, 9, 1–16. [Google Scholar]
  20. Branco, M.; Guerreiro, L.M. Seismic rehabilitation of historical masonry buildings. Eng. Struct. 2011, 33, 1626–1634. [Google Scholar] [CrossRef] [Scilit]
  21. Gilani, A.S.; Miyamoto, H.K.; Kohagura, T. Seismic Rehabilitation of a Nine-Story Hospital Building Using Fluid Viscous Dampers. In Proceedings of the Structures Congress 2006: Structural Engineering and Public Safety; American Society of Civil Engineers (ASCE): Reston, VA, USA, 2006. [Google Scholar]
  22. Rinaldin, G.; Miniussi, C.; Amadio, C. Cyclic behavior of masonry walls strengthened by tie rods. Eng. Struct. 2019, 184, 287–300. [Google Scholar] [CrossRef] [Scilit]
  23. Valdés, V.M.; Pupo, D.; Fernández, R.M.; Martínez, R.; Recarey, C.A. New Proposal for Seismic Rehabilitation of Hospitals in Cuba. Open Access Libr. J. 2019, 6, 1–5. [Google Scholar]
  24. Motra, G.B.; Paudel, S. Performance evaluation of strengthening options for institutional brick masonry buildings: A case study of Pulchowk Campus. Prog. Disaster Sci. 2021, 10, 100173. [Google Scholar] [CrossRef] [Scilit]
  25. Shabani, A.; Kioumarsi, M.; Zucconi, M. State of the art of simplified analytical methods for seismic vulnerability assessment of unreinforced masonry buildings. Eng. Struct. 2021, 239, 112280. [Google Scholar] [CrossRef] [Scilit]
  26. Deng, M.; Yang, S. Experimental and numerical evaluation of confined masonry walls retrofitted with engineered cementitious composites. Eng. Struct. 2020, 207, 110249. [Google Scholar] [CrossRef] [Scilit]
  27. Munjal, P.; Singh, S. Out-of-plane response of ECC-strengthened masonry walls. J. Struct. Integr. Maint. 2020, 5, 18–30. [Google Scholar] [CrossRef] [Scilit]
  28. El-Kholy, A.M.; Sayed, S.M.; El-Assaly, M.M. Nonlinear macromodeling of multistory RC buildings with masonry infill walls. Bull. Earthq. Eng. 2024, 22, 1451–1484. [Google Scholar] [CrossRef] [Scilit]
  29. El-Kholy, A.M.; Sayed, S.M.; El-Assaly, M.M.; Ismail, M.K. Modeling of masonry infilled RC frames with different aspect ratios using plastic hinge and equivalent strut. J. Eng. Appl. Sci. 2025, 72, 18. [Google Scholar] [CrossRef] [Scilit]
  30. Usta, P.; Onat, Ö.; Bozdağ, Ö. Effect of masonry infill walls on the nonlinear response of reinforced concrete structure: October 30, 2020 İzmir earthquake case. Eng. Fail. Anal. 2023, 146, 107081. [Google Scholar] [CrossRef] [Scilit]
  31. Hassanieh, A.; Gharib, M.; King, M. A Simplified Modelling Approach for the Practical Engineering Assessment of Unreinforced Masonry Structures Using Layered Shell Elements. In Proceedings of the SAHC Conference; International Centre for Numerical Methods in Engineering (CIMNE): Barcelona, Spain, 2021. [Google Scholar]
  32. Patel, V.; Joshi, A.A. Incremental dynamic analysis of containment reinforced masonry buildings using equivalent frame model. Int. J. Emerg. Technol. Innov. Res. 2021, 77, 384–394. [Google Scholar]
  33. Ali, A.H.; Al-Hussein, A.; Majeed, F.H. SAP2000 Analysis of Seismic Reinforcement Using Carbon Fiber Reinforced Polymer and Textile Reinforced Mortar Jacketing. Math. Model. Eng. Probl. 2023, 10, 1105. [Google Scholar] [CrossRef] [Scilit]
  34. Almassri, B.; Ayyad, H. Seismic assessment and retrofitting of RC building using concrete jacketing and CFRP (a finite element modelling study). J. Appl. Eng. Sci. 2025, 23, 198–207. [Google Scholar] [CrossRef] [Scilit]
  35. Wijanto, S.; Andriono, T.; Tanudjaja, J. A study on finite element modelling and analysis with respect to experimental results of strengthened unreinforced masonry walls with and without kevlar-FRP. Civ. Eng. Dimens. 2021, 23, 67–77. [Google Scholar] [CrossRef] [Scilit]
  36. D’Ayala, D. Assessing the seismic vulnerability of masonry buildings. In Handbook of Seismic Risk Analysis and Management of Civil Infrastructure Systems; Elsevier: Amsterdam, The Netherlands, 2013; pp. 334–365. [Google Scholar]
  37. Rinaldin, G.; Amadio, C.; Gattesco, N. Review of experimental cyclic tests on unreinforced and strengthened masonry spandrels and numerical modelling of their cyclic behaviour. Eng. Struct. 2017, 132, 609–623. [Google Scholar] [CrossRef] [Scilit]
  38. FEMA. Prestandard and Commentary for the Seismic Rehabilitation of Buildings (FEMA 356); F.E.M. Agency: Washington, DC, USA, 2000. [Google Scholar]
  39. Penna, A.; Lagomarsino, S.; Galasco, A. A nonlinear macroelement model for the seismic analysis of masonry buildings. Earthq. Eng. Struct. Dyn. 2014, 43, 159–179. [Google Scholar] [CrossRef] [Scilit]
  40. Hernoune, H.; Benabed, B.; Alshugaa, M.; Abousnina, R.; Guettala, A. Strengthening of masonry walls with CFRP composite: Experiments and numerical modeling. Epa. J. Silic. Based Compos. Mater. 2020, 72, 2–11. [Google Scholar] [CrossRef] [Scilit]
  41. D’Altri, A.M.; Carloni, C.; de Miranda, S.; Castellazzi, G. Numerical modeling of FRP strips bonded to a masonry substrate. Compos. Struct. 2018, 200, 420–433. [Google Scholar] [CrossRef] [Scilit]
  42. Facconi, L.; Lucchini, S.S.; Minelli, F.; Plizzari, G.A. Analytical model for the in-plane resistance of masonry walls retrofitted with steel fiber reinforced mortar coating. Eng. Struct. 2023, 275, 115232. [Google Scholar] [CrossRef] [Scilit]
  43. Quagliarini, E.; Maracchini, G.; Clementi, F. Uses and limits of the Equivalent Frame Model on existing unreinforced masonry buildings for assessing their seismic risk: A review. J. Build. Eng. 2017, 10, 166–182. [Google Scholar] [CrossRef] [Scilit]
  44. Petrovčič, S.; Kilar, V. Seismic failure mode interaction for the equivalent frame modeling of unreinforced masonry structures. Eng. Struct. 2013, 54, 9–22. [Google Scholar] [CrossRef] [Scilit]
  45. Ferreira, T.M.; Mendes, N.; Silva, R. Multiscale seismic vulnerability assessment and retrofit of existing masonry buildings. Buildings 2019, 9, 91. [Google Scholar] [CrossRef] [Scilit]
  46. Keshmiry, A.; Hassani, S.; Dackermann, U.; Li, J. Assessment, repair, and retrofitting of masonry structures: A comprehensive review. Constr. Build. Mater. 2024, 442, 137380. [Google Scholar] [CrossRef] [Scilit]
  47. Petrovčič, S.; Kilar, V. Design considerations for retrofitting of historic masonry structures with externally bonded FRP systems. Int. J. Archit. Herit. 2022, 16, 957–976. [Google Scholar] [CrossRef] [Scilit]
  48. Petrovčič, S.; Prašnikar, P.; Kilar, V. Seismic assessment and FRCM strengthening of post-war masonry residential buildings: A case study on building typologies. Int. J. Disaster Risk Reduct. 2025, 119, 105341. [Google Scholar] [CrossRef] [Scilit]
  49. Rezapour, M.; Ghassemieh, M.; Motavalli, M.; Shahverdi, M. Numerical modeling of unreinforced masonry walls strengthened with Fe-based shape memory alloy strips. Materials 2021, 14, 2961. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  50. Hussain, M.; Peng, B. Numerical simulation to investigate the performance of existing masonry walls strengthened by ultra high-performance concrete layer. J. Umm Al-Qura Univ. Eng. Archit. 2025, 16, 977–993. [Google Scholar] [CrossRef] [Scilit]
  51. Estevan, L.; Torres, B.; Baeza, F.J.; Gattulli, V.; Ivorra, S. Enhancing fire resistance of masonry structures: The potential of ultra high performance concrete (UHPC). Constr. Build. Mater. 2024, 425, 136088. [Google Scholar] [CrossRef] [Scilit]
  52. Ghiassi, B.; Soltani, M.; Tasnimi, A.A. Seismic evaluation of masonry structures strengthened with reinforced concrete layers. J. Struct. Eng. 2012, 138, 729–743. [Google Scholar] [CrossRef] [Scilit]
  53. Gupta, A.; Meena, G.K.; Singhal, V. Strengthening of autoclaved aerated concrete (AAC) masonry wallettes with fabric reinforced cementitious matrix for in-plane shear and out-of-plane loads. In Structures; Elsevier: Amsterdam, The Netherlands, 2023. [Google Scholar]
  54. Hwang, S.H.; Kim, S.; Mun, J.H.; Yang, K.H. In-plane seismic performance of open masonry walls retrofitted with steel-bar truss units. Constr. Build. Mater. 2022, 320, 126278. [Google Scholar] [CrossRef] [Scilit]
  55. Özkılıç, Y.O.; Aksoylu, C.; Arslan, M.H. Experimental and numerical investigations of steel fiber reinforced concrete dapped-end purlins. J. Build. Eng. 2021, 36, 102119. [Google Scholar] [CrossRef] [Scilit]
  56. Magenes, G.; Morandi, P.; Penna, A.; Ferrata, V. D7.1c: Test results on the behaviour of masonry under static cyclic in plane lateral loads. In ESECMaSE Poject; University of Pavia: Pavia, Italy, 2008. [Google Scholar]
  57. Meireles, H.; Bento, R. Rehabilitation and Strengthening of Old Masonry Buildings; Report ICIST, DTC(02); University of Lisbon: Lisbon, Portugal, 2013. [Google Scholar]
  58. Liu, S.; Liu, Y. Finite element analysis of UHPC reinforced masonry structure. J. Mechatron. Artif. Intell. Eng. 2020, 1, 73–82. [Google Scholar] [CrossRef] [Scilit]
  59. Najafgholipour, M.; Dehghan, S.; Kamrava, A. In-plane shear behavior of masonry walls strengthened with steel fiber-reinforced concrete overlay. Asian J. Civ. Eng. 2018, 19, 553–570. [Google Scholar] [CrossRef] [Scilit]
  60. Amir Hossein Karimi, M.S.K.; Kheyroddin, A.; Shahkarami, A.A. Experimental and Numerical Study on Seismic Behavior of An Infilled Masonry Wall Compared to An Arched Masonry Wall. Structures 2016, 8, 144–153. [Google Scholar] [CrossRef] [Scilit]
  61. Elide Nastri, M.T.; Todisco, P. Calibration of concrete damaged plasticity materials parameters for tuff masonry types of the Campania area. Eng. Struct. 2023, 283, 115927. [Google Scholar] [CrossRef] [Scilit]
  62. Kaushik, H.B.; Rai, D.C.; Jain, S.K. Stress-strain characteristics of clay brick masonry under uniaxial compression. J. Mater. Civ. Eng. 2007, 19, 728–739. [Google Scholar] [CrossRef] [Scilit]
  63. Kurdo, F.; Abdulla, L.S.C.; Gillie, M. Simulating masonry wall behaviour using a simplified micro-model approach. Eng. Struct. 2017, 151, 349–365. [Google Scholar] [CrossRef] [Scilit]
  64. Pawan Agnihotri, V.S.; Rai, D.C. Effect of in-plane damage on out-of-plane strength of unreinforced masonry walls. Eng. Struct. 2013, 57, 1–11. [Google Scholar] [CrossRef] [Scilit]
  65. Albu-Jasim, Q.; Muliana, A. Calibration of a concrete damage plasticity model used to simulate the material components of unreinforced masonry reinforced concrete infill frames. Mater. Struct. 2022, 55, 36. [Google Scholar] [CrossRef] [Scilit]
  66. Rainone, L.S.; Tateo, V.; Casolo, S.; Uva, G. About the use of concrete damage plasticity for modeling masonry post-elastic behavior. Buildings 2023, 13, 1915. [Google Scholar] [CrossRef] [Scilit]
  67. Tran, T.T.; Pham, T.M.; Tran, D.T.; Ha, N.S.; Hao, H. Modified plastic damage model for steel fiber reinforced concrete. Struct. Concr. 2025, 26, 13–42. [Google Scholar] [CrossRef] [Scilit]
  68. Cavaleri, L.; Di Trapani, F. Cyclic response of masonry infilled RC frames: Experimental results and simplified modeling. Soil Dyn. Earthq. Eng. 2014, 65, 224–242. [Google Scholar] [CrossRef] [Scilit]
  69. Wilson, E. CSI Analysis Reference Manual for SAP 2000, ETABS, SAFE and CSI Bridge; Computers and Structure, Inc.: Berkeley, CA, USA, 2015. [Google Scholar]
  70. ACI 318R-02; Building Code Requirements for Structural Concrete (ACI 318-02) and Commentary. American Concrete Institute: Farmington Hills, MI, USA, 2002.
  71. American Society of Civil Engineers. Minimum Design Loads and Associated Criteria for Buildings and Other Structures; American Society of Civil Engineers: Reston, VA, USA, 2017. [Google Scholar] [CrossRef] [Scilit]
  72. FEMA P695; Quantification of Building Seismic Performance Factors. Federal Emergency Management: Washington, DC, USA, 2009.
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Article metric data becomes available approximately 24 hours after publication online.