Skip to Content
  • Article
  • Open Access

4 November 2026

22 Pages

Acute Changes in Acromial Distance, Pulmonary Function, and Peripheral Microvascular Perfusion Following One-Handed Versus Two-Handed Smartphone Use in University Students: A Secondary Analysis of a Randomized Parallel-Group Trial

,
,
and
Faculty of Allied Health Sciences, Burapha University, Chonburi 20131, Thailand
*
Author to whom correspondence should be addressed.

Abstract

Background and Objectives: The acute effects of one-handed versus two-handed smartphone use on shoulder position, pulmonary function, and local cutaneous microvascular perfusion remain unclear. This secondary analysis of a randomized parallel-group trial aimed to explore differences in forced vital capacity (FVC), other pulmonary function parameters, bilateral supine acromial distance, and local cutaneous microvascular perfusion between the two smartphone-handling conditions. Methods: In this randomized parallel-group pretest–posttest trial, 63 university students were allocated to either one-handed (n = 33) or two-handed (n = 30) smartphone use for 30 min. Outcomes were assessed before and after the task. Baseline-adjusted between-group comparisons were conducted using post hoc exploratory analyses of covariance. Results: FVC decreased in the two-handed group (mean change: −0.13 ± 0.06 L), whereas no significant change was observed in the one-handed group. Baseline-adjusted post-task FVC was higher in the one-handed group (adjusted mean difference, 0.16 L; 95% CI, 0.06–0.26 L; p = 0.002). The FEV1/FVC ratio also differed between groups after baseline adjustment (p = 0.007). Vital capacity decreased significantly in both groups, while inspiratory reserve volume increased and expiratory reserve volume decreased significantly within the one-handed group. Supine acromial distance increased by 0.5–0.6 cm in both groups, without significant baseline-adjusted between-group differences. Right little finger perfusion decreased significantly within the one-handed group (p = 0.032), whereas no significant within-group changes were observed at the other measurement sites. No significant baseline-adjusted between-group differences in local cutaneous microvascular perfusion were detected. Conclusions: Thirty minutes of one-handed or two-handed smartphone use was followed by small, acute changes in selected pulmonary function parameters and increased supine acromial distance in healthy university students. An exploratory baseline-adjusted analysis identified differences in post-task FVC and FEV1/FVC between the two handling conditions. Although a within-group reduction in right little finger perfusion was observed in the one-handed group, no significant between-group difference was detected. As a post hoc secondary analysis with multiple unadjusted comparisons, the findings are exploratory and subject to potential Type I error and selective emphasis on significant results. The clinical significance and reproducibility of these changes remain uncertain.

Article Metrics

Citations

Article Access Statistics

Article metric data becomes available approximately 24 hours after publication online.