Skip to Content
  • Review
  • Open Access

26 September 2026

22 Pages

Modern Imaging and the Future of Prostate Biopsy: Rethinking Systematic Sampling

,
,
,
,
and
1
Department of Urology, Democritus University of Thrace, 68100 Alexandroupolis, Greece
2
Endoscopy Unit, Democritus University of Thrace, 68100 Alexandroupolis, Greece
3
Department of Medical Oncology, University General Hospital of Alexandroupolis, Faculty of Medicine, Democritus University of Thrace, 68100 Alexandroupolis, Greece
*
Author to whom correspondence should be addressed.
This article belongs to the Section Medical Imaging

Abstract

Prostate biopsy has shifted from systematic, non-targeted sampling towards imaging-directed approaches, but the extent to which systematic cores can be safely reduced remains uncertain. This review examines current evidence on contemporary biopsy strategies in men with suspected prostate cancer. A structured PubMed/MEDLINE search through July 2026 identified studies evaluating multiparametric magnetic resonance imaging (mpMRI), MRI-targeted biopsy, perilesional, regional and ipsilateral sampling, micro-ultrasound, prostate-specific membrane antigen positron emission tomography (PSMA PET), radiomics, and artificial intelligence. MRI-targeted biopsy improves the detection of clinically significant disease and reduces low-grade cancer diagnosis, yet targeted sampling alone may miss or undergrade clinically important tumours. Available evidence suggests that perilesional, regional, or ipsilateral sampling can preserve much of the diagnostic contribution of systematic biopsy while reducing unnecessary cores, although the evidence remains heterogeneous and is frequently retrospective. Micro-ultrasound and PSMA PET may further refine lesion localisation, while artificial intelligence may support risk assessment and biopsy planning. Current evidence supports selective reduction in systematic sampling, not its universal omission. Future biopsy strategies should integrate clinical risk, imaging quality, lesion characteristics, and targeting confidence and require prospective multicentre validation before broad implementation.

1. Introduction

Prostate biopsy remains the definitive test for the diagnosis of prostate cancer, although the optimal approach to tissue sampling continues to evolve. For many years, systematic biopsy represented the gold standard diagnostic method, providing broad gland coverage through non-targeted sampling. However, this approach requires multiple cores, increases the detection of low-grade disease, and may still fail to identify clinically significant tumours.
The introduction of multiparametric magnetic resonance imaging (mpMRI) substantially changed this diagnostic pathway by allowing suspicious lesions to be visualised before biopsy. MRI-targeted biopsy improves the detection of clinically significant prostate cancer while reducing the diagnosis of clinically insignificant disease compared with systematic biopsy alone [1,2,3]. These findings established mpMRI as a central component of contemporary biopsy planning. Nevertheless, targeted biopsy is not sufficient in every patient. MRI-invisible tumours, variation in image interpretation, targeting error, and multifocal disease may result in clinically significant cancer being missed or underestimated, which explains why systematic cores can still provide additional diagnostic information [4,5].
The question is no longer whether systematic sampling has any value, but whether a complete bilateral template is necessary in every patient with a positive MRI. Full systematic biopsy increases the number of cores and may add disproportionately to the detection of Grade Group 1 disease. This has led to growing interest in more selective approaches, including perilesional, regional, and ipsilateral sampling, which aim to retain the diagnostic benefit of additional cores while avoiding low-yield sampling elsewhere in the gland. At the same time, micro-ultrasound, prostate-specific membrane antigen positron emission tomography, radiomics, and artificial intelligence are providing additional tools for lesion localisation and risk assessment.
Recent reviews have described the broader development of prostate cancer imaging and artificial intelligence [6,7], but less attention has been paid to how these advances should influence the number and spatial distribution of biopsy cores. The present review focuses on the relationship between modern imaging and biopsy strategy, particularly the possibility of reducing systematic sampling without compromising detection of clinically significant cancer.

2. Literature Search and Study Selection

A structured literature search was performed in PubMed/MEDLINE to identify studies relevant to contemporary imaging-guided prostate biopsy and reduced systematic sampling. The search included combinations of terms related to “prostate cancer”, “prostate biopsy”, “multiparametric MRI”, “MRI-targeted biopsy”, “systematic biopsy”, “perilesional biopsy”, “regional biopsy”, “ipsilateral biopsy”, “micro-ultrasound”, “PSMA PET”, “radiomics”, and “artificial intelligence”. No lower publication-date limit was applied, and studies indexed up to 12 July 2026 were considered. Reference lists of relevant reviews, meta-analyses, guidelines, and key prospective studies were also checked for additional publications.
Randomised trials, prospective and multicentre studies, systematic reviews, meta-analyses, and large comparative cohorts were prioritised. Studies were included when they provided data on clinically significant prostate cancer detection, the additional diagnostic contribution of systematic sampling, reduced-core biopsy strategies, or emerging imaging modalities used for biopsy guidance or patient selection. Studies dealing exclusively with biochemical recurrence, treatment response, or imaging applications unrelated to primary diagnosis and biopsy planning were excluded. Studies of primary staging were considered only when they also contained information relevant to initial diagnosis, lesion localisation, or biopsy guidance. Conference abstracts, editorials, non-peer-reviewed reports, and studies with insufficient information on biopsy strategy or clinically significant cancer detection were not included. Study identification and selection were performed collaboratively by the authors involved in the literature search (G.T., D.D., and S.L.), with final inclusion decisions reached by consensus. Data extraction was not performed independently in duplicate.
This comprehensive review used a structured narrative approach. This approach was chosen because the review covers a broad and methodologically diverse field, including multiple imaging modalities, biopsy techniques, sampling strategies, and emerging technologies, rather than a single intervention or diagnostic comparison. The aim was to critically synthesise the available evidence and highlight areas of agreement, uncertainty, and future research. Given this scope, the review did not follow a formal systematic-review protocol and did not include a PRISMA flow diagram or a formal study-level risk-of-bias assessment.
ClinicalTrials.gov was searched using the terms “prostate biopsy”, “perilesional biopsy”, “regional biopsy”, “PSMA PET” and “artificial intelligence”, restricted to interventional and diagnostic studies with a recruiting, active or not-yet-recruiting status, in order to identify ongoing work relevant to biopsy extent. Unless otherwise stated, clinically significant prostate cancer denotes International Society of Urological Pathology Grade Group ≥ 2. Where a cited study applied a different threshold, this is indicated in the text or in the corresponding table.

3. mpMRI as the Foundation of Contemporary Prostate Biopsy

Multiparametric magnetic resonance imaging (mpMRI) has become central to the diagnostic assessment of men with suspected prostate cancer. Its main contribution is not merely the visualisation of suspicious lesions, but the introduction of a triage step before tissue sampling. In the conventional pathway, an elevated prostate-specific antigen level or an abnormal digital rectal examination led directly to systematic biopsy. With an MRI-directed pathway, the decision to biopsy can be refined based on imaging results and the patient’s clinical risk, while suspicious areas can be sampled directly.
The PROMIS study established the diagnostic role of mpMRI as a pre-biopsy triage test. Among 576 men who underwent mpMRI followed by both transrectal ultrasound-guided and template mapping biopsy, mpMRI reached a sensitivity of 93% and a negative predictive value of 89%. Significant disease in PROMIS was defined as Gleason ≥ 4 + 3 or a maximum cancer core length ≥ 6 mm, a broader threshold than the Grade Group ≥ 2 criterion used in most later work, so these figures are not directly comparable with those quoted below. The investigators estimated that mpMRI used as an initial triage test could allow about 27% of men to avoid immediate biopsy while reducing detection of clinically insignificant disease [8].
Evidence from biopsy-naïve populations established the MRI-directed pathway. In PRECISION, men underwent targeted biopsy only when MRI was suspicious; 28% avoided biopsy, while detection of clinically significant cancer increased and detection of clinically insignificant disease decreased relative to standard systematic biopsy [1]. STHLM3-MRI confirmed that MRI-directed screening maintained clinically significant cancer detection while reducing low-risk diagnoses [9], and a related risk-prediction trial showed that MRI can be incorporated into a sequence of selective tests rather than applied after every elevated PSA result [10]. Similar reductions in unnecessary biopsies and low-grade cancer were observed in a large multicentre cohort [11] and a phase III randomised trial [12]. Meta-analyses confirmed greater detection of clinically significant cancer and less Grade Group 1 disease than with systematic biopsy alone [2,3]; however, a Cochrane review emphasised that some clinically significant cancers may still be missed [13].
mpMRI is not, however, an infallible exclusion or localisation test. Its performance is influenced by acquisition quality, scanner characteristics, adherence to technical standards, and radiologist experience. The PI-RADS Steering Committee has emphasised that the diagnostic benefits of an MRI-directed pathway depend on standardised image acquisition, interpretation, reporting, and integration of MRI findings into the biopsy pathway [14]. Some significant tumours remain inconspicuous, particularly when they are small or located in areas where benign tissue changes complicate interpretation. A visible lesion may also be inadequately sampled because of registration error, prostate deformation, needle displacement, or operator-related limitations. Paired biopsy studies, including MRI-FIRST, have shown that targeted and systematic cores detect overlapping but not identical groups of clinically significant cancers [4]. This residual discordance explains why a negative MRI cannot be interpreted independently of PSA density, digital rectal examination, family history, and the overall probability of cancer.
Current guidelines position mpMRI as the basis of modern biopsy planning, but not as a universal justification for omitting additional sampling. The European Association of Urology recommends MRI before biopsy and favours lesion-centred targeted and perilesional sampling in men with positive imaging, while allowing biopsy deferral after negative or equivocal MRI only when clinical suspicion is low [15]. Thus, mpMRI has established the framework for a more selective diagnostic pathway; the remaining question is how far systematic sampling can be reduced without compromising detection of clinically significant disease. The evolution of prostate biopsy strategies from conventional systematic sampling to contemporary imaging-directed and risk-adapted approaches is summarised in Figure 1.
Figure 1. Evolution of prostate biopsy strategies in the imaging era. The figure illustrates the conceptual transition from gland-wide systematic sampling to MRI-directed and increasingly individualised biopsy. Targeted biopsy improves lesion-directed sampling, while perilesional, regional, or ipsilateral cores aim to retain clinically significant cancer detection with fewer low-yield cores. Micro-ultrasound, PSMA PET, and AI are emerging adjuncts rather than universally validated replacements for MRI-based pathways. This is a conceptual framework, not a validated clinical algorithm. Abbreviations: AI, artificial intelligence; GG1, Grade Group 1; mpMRI, multiparametric magnetic resonance imaging; MRI, magnetic resonance imaging; PET, positron emission tomography; PSMA, prostate-specific membrane antigen.

4. MRI-Targeted Biopsy and the Residual Role of Systematic Sampling

MRI-targeted biopsy has changed the diagnostic balance in prostate cancer by directing tissue sampling towards lesions most likely to harbour clinically significant disease. In contrast to systematic biopsy, which samples the gland according to a predetermined template, targeted biopsy links imaging findings to histological confirmation. This improves sampling efficiency and reduces the number of cores obtained from MRI-normal tissue. The clinical relevance of this change was demonstrated in PRECISION, in which an MRI-directed pathway detected more clinically significant prostate cancer than standard systematic biopsy while reducing the diagnosis of clinically insignificant tumours [1]. A subsequent meta-analysis of 14,709 men similarly found that MRI-targeted biopsy detected more clinically significant and fewer clinically insignificant cancers than systematic biopsy [2].
These findings, however, do not establish that targeted biopsy is sufficient in every patient. MRI-visible lesions account for most, but not all, clinically significant cancers, and a technically successful biopsy depends on several sequential steps. The lesion must first be visible and correctly interpreted on MRI; its position must then be transferred accurately to ultrasound or the in-bore biopsy environment; finally, the needle must traverse the biologically relevant part of the lesion. Errors at any stage may produce a false-negative or undergraded result. Lesion size, anatomical location, prostate deformation, operator experience, targeting method, and the number of targeted cores may all influence diagnostic yield. Mechanical and robotic systems can improve the reproducibility of needle placement, but they do not eliminate all sources of targeting error. Differences between MRI and biopsy positioning, changes in prostate shape, patient movement, and needle deflection may still alter the final needle trajectory [16]. Moreover, prostate cancer is frequently multifocal, and a dominant MRI lesion does not exclude a separate significant focus elsewhere in the gland.
MRI-FIRST illustrates the complementary yield of targeted and systematic sampling. Among 251 biopsy-naïve men, clinically significant cancer was identified in 94: 13 cancers were detected only by systematic biopsy, 19 only by targeted biopsy, and 62 by both methods [4]. Omitting systematic cores would have missed clinically significant disease in 5.2% of the entire cohort. PAIREDCAP showed a similar pattern in 248 biopsy-naïve men with MRI-visible lesions: targeted and systematic approaches often identified different tumour foci, and their combination achieved the highest detection of clinically significant cancer [17]. These studies show that the two approaches are complementary rather than interchangeable.
Prostatectomy-correlated data provide a second rationale for additional sampling. Combined biopsy showed the closest agreement with whole-mount pathology: upgrading to Grade Group 3 or higher at surgery occurred in 3.5% of men assessed by combined biopsy, compared with 8.7% after targeted biopsy alone and 16.8% after systematic biopsy alone [5]. Additional systematic cores may improve grade assessment as well as cancer detection, with implications for surveillance, focal treatment, radical therapy, and staging.
The residual benefit of systematic biopsy must nevertheless be weighed against its disadvantages. A full bilateral template adds cores and procedural burden and exposes a larger volume of prostatic tissue to needle sampling. It also detects additional Grade Group 1 disease, potentially leading to anxiety, repeated surveillance procedures, and overtreatment. The diagnostic gain from systematic biopsy is not uniformly beneficial: identification of an MRI-occult Grade Group 2 tumour may alter management, whereas detection of a small low-grade focus may add burden without offering a comparable oncological benefit. Meta-analytic evidence confirms the greater selectivity of MRI-targeted biopsy for clinically significant disease and its lower detection of clinically insignificant cancer [2,3]. Recent randomised evidence indicates that the systematic component of combined biopsy can be reduced without being abandoned. In the SEXTANT-PRO non-inferiority trial, 506 biopsy-naïve men with a single MRI-visible lesion were randomised to undergo MRI-targeted biopsy combined with either six-core sextant systematic sampling or conventional 12-core systematic biopsy. Clinically significant prostate cancer was detected in 138 of 254 men (54.3%) with sextant sampling and in 138 of 252 (54.8%) with the 12-core template (difference −0.5%, 95% confidence interval −9.2% to 8.3%), meeting the prespecified non-inferiority margin of −15%. That margin is wide for a diagnostic question with oncological consequences, and its lower limit still admits a loss of approximately nine percentage points in clinically significant cancer detection. The trial provides randomised evidence that, in biopsy-naïve men with a solitary MRI-visible lesion, halving the systematic template preserves detection while reducing tissue sampling [18].
The balance between diagnostic protection and unnecessary sampling is also unlikely to be identical across all patients. Men undergoing their first biopsy, those assessed with lower-quality or externally performed MRI, patients with large or anatomically challenging glands, and cases in which targeting confidence is limited may derive greater benefit from broader sampling than men with a highly conspicuous lesion evaluated in an experienced centre. Such heterogeneity limits the validity of a uniform targeted-only strategy and explains why the residual role of systematic biopsy remains clinically relevant.
The unresolved question is whether the residual value of systematic sampling requires a complete bilateral template in every MRI-positive patient. In selected cohorts, most additional clinically significant disease is detected on the side of the MRI-visible lesion, whereas exclusively contralateral findings contribute relatively little [19]. This observation underpins perilesional, regional, and ipsilateral strategies designed to retain diagnostic protection while reducing low-yield cores and Grade Group 1 detection.

5. Perilesional, Regional, and Ipsilateral Biopsy Strategies

Spatial uncertainty around an MRI-visible lesion provides the rationale for limited additional sampling. The MRI contour may not correspond exactly to the histological tumour boundary, and registration error, prostate deformation, needle deflection, or operator-related error may divert a targeted core into adjacent tissue. Additional cores near the target can compensate for these limitations without routinely sampling the entire MRI-negative gland. Perilesional, regional, and ipsilateral strategies are different practical expressions of this principle.
Terminology remains inconsistent. Perilesional biopsy generally refers to cores taken immediately around the MRI target, regional biopsy includes the target and adjacent sectors, and ipsilateral biopsy retains systematic sampling from the involved lobe while omitting the contralateral lobe. These approaches also differ technically: a narrow perilesional template requires accurate segmentation and reliable fusion or in-bore guidance, whereas ipsilateral sampling is easier to reproduce during cognitive targeting. The recurrent 10 mm margin is operationally convenient but biologically arbitrary: it assumes reproducible lesion boundaries and needle placement and is unlikely to transfer unchanged across fusion, in-bore, and cognitive workflows. All three strategies aim to recover clinically significant cancer missed by targeted cores while reducing low-yield sampling elsewhere.
Spatial mapping provides the biological rationale for this approach. Spatial mapping by Brisbane and colleagues described the visible lesion as the tumour “umbra” and the adjacent area as its “penumbra”; 90% of cancer-positive cores lay within 10 mm of the nearest MRI lesion [20]. Because this was a core-level analysis, the estimate should not be transferred directly to patient-level decisions. Noujeim and colleagues subsequently reported that a 10 mm perilesional strategy detected clinically significant cancer in 35% of patients, compared with 37% using targeted plus full systematic biopsy [21]. Disease beyond the margin was more frequent in patients with adverse risk features, arguing against a fixed distance for every case.
Ipsilateral-sampling cohorts provide complementary evidence. Bryk and colleagues reported 96% sensitivity for Grade Group 2 or higher disease when MRI-targeted biopsy was combined with ipsilateral systematic cores, with less detection of insignificant cancer than with bilateral systematic sampling [22]. In the Freifeld cohort, sensitivity increased from 85.5% with targeted biopsy alone to 96.4% after ipsilateral systematic cores were added [23]. These results position ipsilateral or regional sampling between targeted-only biopsy and a full bilateral template.
Later cohorts reported a similar pattern. In the Jager cohort of men with a unilateral MRI lesion, targeted plus ipsilateral systematic biopsy retained 98.6% sensitivity for clinically significant disease, missing 1.4% of such cancers and detecting fewer insignificant cancers [24]. Ruan and colleagues estimated in a larger reconstructed cohort that omitting contralateral cores would have missed only 0.3% of clinically significant cancers identified by the full combined approach [25]. In the cognitive-targeting study by Yu and colleagues, targeted plus ipsilateral sampling detected 95.9% of clinically significant cancers [26]. Because fusion platforms are not universally available, strategies dependent on software-defined margins may be difficult to reproduce in community or resource-limited settings.
Direct protocol studies address an important limitation of retrospective reconstructions of a full biopsy. In the Hagens cohort, targeted plus perilesional cores detected 96.8% of the clinically significant cancers found by the full combined strategy, reduced the mean core count by 5.2, and avoided some systematic-only Grade Group 1 diagnoses [27]. The prospective, non-randomised, surgeon-blinded Duwe study was less supportive: targeted plus perilesional biopsy did not preserve clinically significant cancer detection to the same extent as targeted plus full systematic biopsy [28]. Although smaller than several reconstructed cohorts, the Duwe study carries disproportionate evidential weight because it tested an intentionally limited procedure prospectively. Retrospective reconstruction from a complete biopsy assumes that the retained cores would have been placed identically had the operator known that no further cores would be taken. The randomised Jiang trial of 434 biopsy-naïve men evaluated regional saturation around the MRI-defined lesion and found clinically significant cancer detection comparable to combined targeted and systematic biopsy (44.1% vs. 40.7%) with fewer cores [29]. These data support a regional safety margin but do not define a universally optimal number, distance, or distribution of cores.
Pooled analyses place regional biopsy between targeted-only and full systematic sampling. A meta-analysis of eight studies including 2603 MRI-positive men found no statistically significant difference in Grade Group 2 or higher detection between targeted plus regional biopsy and targeted plus full systematic biopsy. Regional sampling, however, detected significantly more clinically significant cancer than targeted biopsy alone [30]. A later meta-analysis of 21 studies similarly reported clinically significant cancer detection rates of 44.2% with regional sampling and 46.1% with full systematic sampling, while the full approach diagnosed more Grade Group 1 disease [31]. These findings support selective reduction in background sampling, not its removal.
A network meta-analysis comparing 13 biopsy strategies in MRI-positive patients found that targeted biopsy plus ipsilateral systematic sampling achieved clinically significant cancer detection comparable to targeted biopsy plus full systematic sampling, whereas targeted biopsy alone provided less diagnostic protection [32]. This synthesis supports selective reduction rather than complete omission of systematic sampling.
This interpretation is reflected in current European Association of Urology guidance. For a positive MRI, targeted biopsy should be combined with perilesional sampling for PI-RADS 4–5 lesions; in PI-RADS 3 lesions, biopsy decisions should also incorporate clinical suspicion, particularly PSA density and family history. The recommendation remains weak because the number and spatial distribution of perilesional cores have not been standardised, and the underlying evidence is largely observational [15].
Guideline positions are not uniform. The EAU recommends targeted biopsy with perilesional sampling for PI-RADS 4–5 lesions and risk-adapted decisions for PI-RADS 3. The AUA/SUO early detection guideline recommends targeted biopsy in biopsy-naïve men with a suspicious MRI lesion and allows systematic template biopsy as a conditional option [33], without endorsing a perilesional template as a substitute. European guidance explicitly supports perilesional sampling, whereas North American guidance is less prescriptive and generally retains systematic sampling as an option. Consider this difference when applying reduced-template data across settings. Table 1 summarises the principal studies.
Table 1. Key studies evaluating reduced systematic sampling in MRI-positive patients.
Several limitations prevent immediate adoption of one reduced template for all patients. Many studies retrospectively reclassified cores obtained during a full combined biopsy, creating a hypothetical limited strategy instead of testing one prospectively. Definitions of “perilesional,” “regional,” and “ipsilateral” vary, as do biopsy route, targeting method, previous biopsy status, lesion number, and reference standard. Whole-mount prostatectomy correlation is uncommon, and small MRI-occult tumours in the contralateral lobe may be underestimated. Broader sampling remains appropriate when MRI quality is uncertain, targeting confidence is low, the gland is large or anatomically difficult, multiple lesions are present, or clinical risk appears disproportionate to the imaging findings. Biopsy route is another source of heterogeneity. With transperineal access, the needle can be directed from the apical region towards the base, facilitating sampling of anterior and apical areas. In contrast, transrectal biopsy approaches the gland from the posterior surface with a more oblique needle trajectory, which may make these regions more difficult to sample. These geometric differences may also influence targeted and perilesional biopsy, as the same number of cores may not provide equivalent anatomical coverage with the two routes. In the PREVENT randomised trial of 658 men, infectious complications occurred in no patient after transperineal biopsy and in four (1.4%) after transrectal biopsy, while clinically significant cancer detection was similar (53% vs. 50%; adjusted difference 2.0%, 95% confidence interval −6.0 to 10) [34]. Reduced-sampling studies used different routes: SEXTANT-PRO, the principal perilesional cohort, and PRIMARY2 used transperineal access, whereas the main ipsilateral cohorts used transrectal access. A template validated with one route cannot be assumed to transfer directly to the other. Future trials should stratify by biopsy access.
The emerging evidence supports a move away from the binary choice between targeted biopsy alone and a full bilateral systematic template. When accurate spatial targeting is available, additional cores concentrated around the lesion may compensate for segmentation and needle-placement error. When such precision is not feasible, ipsilateral systematic sampling provides a pragmatic alternative. The objective is not core minimisation. It is the removal of cores with low diagnostic value, with detection and grading of clinically significant cancer preserved.

6. Micro-Ultrasound

Micro-ultrasound (microUS) has emerged as a real-time imaging method for prostate cancer detection and biopsy guidance. Unlike conventional transrectal ultrasound, which mainly provides anatomical orientation, microUS operates at 29 MHz and offers substantially improved spatial resolution. This allows subtle alterations in glandular and ductal architecture to be assessed during the biopsy itself. Suspicious regions are classified using the Prostate Risk Identification using a Micro-Ultrasound (PRI-MUS) system, a five-point scale in which scores of 3–5 indicate increasing concern for clinically significant prostate cancer. Because lesion identification and needle placement occur on the same platform, microUS avoids the registration step required for MRI–ultrasound fusion [35,36].
The clinical appeal of microUS is a single-session workflow that does not require preprocedural segmentation, dedicated fusion software, or MRI access during biopsy. The operator can survey the gland, identify suspicious areas, direct targeted cores, and add background sampling, which may be useful where MRI capacity is limited. MicroUS is not simply a higher-resolution version of conventional ultrasound: interpretation requires specific training, and inflammation, atrophy, and benign prostatic hyperplasia can mimic cancer [35,36].
Early prospective studies suggested that microUS could detect clinically significant disease at rates comparable to mpMRI. A multicentre prospective registry reported similar diagnostic performance for the two modalities, with high sensitivity for Grade Group 2 or higher cancer using microUS [37]. Meta-analyses found no clear difference between microUS-targeted and MRI-targeted biopsy, although most included studies were observational and varied in protocol, blinding, operator experience, and use of systematic cores [38]. Available comparisons with systematic biopsy did not justify routine omission of background sampling [39].
OPTIMUM provides the strongest comparative evidence. Of 802 randomised biopsy-naïve men, 678 underwent biopsy. In the primary comparison, Grade Group 2 or higher cancer was detected in 47.1% of 121 men assigned to microUS and 42.6% of 331 assigned to MRI-ultrasound fusion (difference 3.52%, 95% confidence interval −3.95% to 10.92%), within the prespecified 10% non-inferiority margin. Because systematic biopsy was performed in every arm, the trial compares microUS plus systematic sampling with MRI plus systematic sampling and does not test omission of background cores [40]. The findings support microUS as a credible image-guided platform but do not establish superiority to mpMRI or make pre-biopsy MRI unnecessary.
The two modalities provide different types of information. Multiparametric MRI offers multiplanar assessment of the entire gland, facilitates evaluation of anterior and apical lesions, and contributes to local staging and treatment planning. MicroUS provides dynamic, high-resolution imaging during needle placement and allows immediate adjustment of the biopsy trajectory. Their findings are often complementary. A lesion visible on one modality may be inconspicuous on the other, and combined use may increase sensitivity at the cost of more targets, additional cores, and more false-positive findings.
Several barriers remain before microUS can be incorporated into routine pathways. PRI-MUS was initially developed for the peripheral zone, while interpretation of anterior and transition-zone abnormalities continues to evolve. Evidence is also limited regarding reproducibility, negative predictive value in biopsy avoidance, cost-effectiveness, and outcomes after a negative examination. Furthermore, systematic sampling was retained in many studies, making it difficult to determine whether microUS alone can safely replace broader biopsy templates.
MicroUS can integrate lesion detection and targeted sampling in real time and may serve as an alternative or complement to MRI guidance. Its ability to reduce systematic cores remains unproven and requires standardised training, external validation, and prospective reduced-sampling trials.

7. PSMA PET in Primary Prostate Cancer Diagnosis and Biopsy Guidance

Prostate-specific membrane antigen positron emission tomography (PSMA PET) is established primarily for staging and recurrence imaging, but its role in the initial diagnosis of prostate cancer is increasingly being investigated. PSMA is a transmembrane protein expressed at higher levels in most prostate cancers than in benign prostatic tissue, with expression generally increasing in biologically aggressive disease. Radiolabelled PSMA ligands provide molecular information that differs from the anatomical and functional information obtained with multiparametric magnetic resonance imaging (mpMRI). This distinction has raised interest in PSMA PET as a complementary method for identifying clinically significant prostate cancer and refining biopsy selection.
The strongest early prospective evidence came from the PRIMARY trial. In this multicentre study, 291 biopsy-naïve men underwent mpMRI, ^68Ga-PSMA PET/CT, and transperineal biopsy. The addition of PSMA PET to mpMRI increased sensitivity for clinically significant prostate cancer from 83% to 97% and improved the negative predictive value from 72% to 91% [41]. The benefit was particularly relevant in men with negative or equivocal MRI findings, in whom molecular imaging identified additional disease not adequately characterised by mpMRI alone. These results suggest that PSMA PET may function more effectively as an adjunct to MRI than as a direct replacement.
The PRIMARY Score was subsequently developed to standardise intraprostatic PSMA PET interpretation. It classifies findings according to uptake pattern, anatomical distribution, and intensity, ranging from no abnormal uptake to intense focal uptake or a maximum standardised uptake value of at least 12 [42]. Increasing PRIMARY Scores were associated with a greater probability of clinically significant disease. Unlike an isolated SUV threshold, this approach incorporates lesion location and uptake pattern and may reduce false-positive interpretation of diffuse activity in benign transition-zone tissue. External assessment has shown promising reproducibility, although broader validation is required before the score can be adopted as a routine equivalent to PI-RADS.
More recently, the PRIMARY2 trial extended this concept to men with equivocal or clinically high-risk non-suspicious MRI findings. In this multicentre phase III randomised non-inferiority trial, 660 men with PI-RADS 2 or 3 findings were assigned either to systematic transperineal biopsy or to a ^68Ga-PSMA-11 PET/CT-guided diagnostic pathway. The co-primary csPCa endpoint was Gleason 3 + 4 with at least 10% pattern 4 or higher, not unrestricted Grade Group ≥ 2. Detection was 12% in the PSMA PET/CT arm and 16% in the systematic-biopsy arm (difference −3.7%, 95% CI −8.9 to 1.5), meeting the prespecified 10% non-inferiority margin. Using the stricter threshold of Gleason ≥4 + 3, detection was 4.2% versus 4.8% (difference −0.63%, 95% CI −3.8 to 2.5). PSMA PET/CT allowed biopsy to be avoided in 49% of patients assigned to the experimental pathway. These findings provide prospective evidence that PSMA PET/CT may have a clinically relevant triage role in selected men with negative or equivocal MRI, reducing biopsy exposure without a clinically unacceptable loss in significant cancer detection [43].
The PEDAL study provided a direct prospective comparison between ^18F-DCFPyL PSMA PET/CT and mpMRI in men undergoing investigation for suspected prostate cancer. mpMRI showed greater diagnostic accuracy than PSMA PET as a stand-alone test, but the two modalities identified partly different lesions, and combined imaging reached a sensitivity of 98.8% with a negative predictive value of 96% [44]. This finding is consistent with their different biological targets: mpMRI assesses tissue architecture, diffusion, and perfusion, whereas PSMA PET reflects cell-surface target expression. A lesion inconspicuous on one modality can remain detectable on the other.
PSMA PET findings can be transferred to ultrasound for targeted biopsy. A meta-analysis of five prospective studies involving 497 men reported pooled sensitivity of 0.89 and specificity of 0.56 for clinically significant cancer [45]. Combined PSMA PET and MRI targeting increased pooled sensitivity to 0.91, with a negative predictive value of 0.85. A larger meta-analysis of 10 studies and 874 patients reported sensitivity of 0.89, specificity of 0.65, and an area under the summary receiver operating characteristic curve of 0.86 [46]. The evidence supports PSMA PET as a targeting adjunct, particularly for PI-RADS 3 lesions, but remains heterogeneous and is derived mainly from specialist centres [46].
Broader pooled analyses support the diagnostic value of PSMA PET, particularly when it is combined with mpMRI [47], and confirm a complementary role while showing that a negative PSMA PET examination cannot reliably exclude clinically significant disease [48]. Integration may improve triage in selected men with persistent suspicion after negative or equivocal MRI, but concordantly negative imaging should not independently justify biopsy omission.
Several limitations restrict routine pre-biopsy use. PSMA expression is heterogeneous, and some clinically significant cancers demonstrate low tracer uptake. Benign prostatic hyperplasia, prostatitis, and other non-malignant processes may also produce uptake, limiting specificity. Diagnostic thresholds, radiotracers, acquisition protocols, reporting systems, and biopsy reference standards remain inconsistent. PSMA PET also involves radiation exposure, higher cost, and more limited availability than ultrasound or MRI. Most published studies were performed in specialist centres and often retained systematic biopsy, preventing firm conclusions about whether molecular imaging can safely reduce background sampling.
PSMA PET is best regarded as an emerging problem-solving modality complementary to mpMRI, not a routine replacement for it. Its most plausible near-term role is in patients with equivocal or discordant findings, particularly when clinical suspicion remains high despite non-diagnostic MRI. Whether it can support the safe reduction in systematic biopsy will require prospective trials that directly compare complete and limited sampling strategies within clearly defined imaging-risk groups.

8. Toward an Integrated, Risk-Adapted Biopsy Strategy

No single biopsy template is appropriate for every man with suspected prostate cancer. Targeted-only biopsy may miss clinically significant disease because of MRI invisibility, lesion underestimation, targeting error, or multifocality, whereas a complete bilateral systematic template adds cores and increases low-grade cancer detection. Contemporary pathways should individualise the extent of background sampling.
The extent of additional sampling should reflect both the reliability of imaging and the patient’s residual risk. Full systematic biopsy remains reasonable when the probability of disease outside the MRI target is substantial. This may include patients with discordantly high prostate-specific antigen density, abnormal digital rectal examination, strong family history, previous atypical histology, multiple or bilateral MRI lesions, and cases in which imaging quality or targeting accuracy is uncertain. Broader sampling may also be justified in large glands, anteriorly located lesions, technically difficult biopsies, and settings where MRI interpretation or biopsy guidance is performed outside experienced centres. In such circumstances, the potential harm of missing or undergrading clinically significant cancer may outweigh the disadvantage of additional cores [2,4,5].
Reduced sampling is most plausible when the MRI lesion is focal and unilateral, imaging quality is satisfactory, and clinical risk is concordant. Most clinically significant cancers detected beyond targeted cores in the relevant studies were near the MRI-visible lesion or within the same lobe [20,21,24,27]. This concentration suggests that adjacent or ipsilateral cores can retain much of the diagnostic contribution of systematic sampling while avoiding low-yield contralateral biopsy. A narrow perilesional margin is more feasible with fusion or in-bore guidance, whereas ipsilateral systematic cores may provide a practical safety margin during cognitive targeting. Across the reduced-template studies reviewed here, omitting distant or contralateral cores missed approximately 0.3–3.2% of clinically significant cancers identified by the full combined approach, while saving a mean of five to six cores and reducing Grade Group 1 diagnoses. The acceptability of this trade-off depends on the individual patient’s residual risk.
Micro-ultrasound may further refine this pathway by providing real-time information during needle placement. A suspicious region that is concordant on mpMRI and micro-ultrasound could be sampled with greater confidence, while discordant findings may identify areas requiring additional cores. The OPTIMUM trial showed that micro-ultrasound-guided biopsy was non-inferior to MRI fusion-guided biopsy for the detection of Grade Group 2 or higher cancer, with systematic sampling retained in both arms, supporting its use as an alternative image-guided platform [40]. Evidence remains insufficient to assume that a negative micro-ultrasound examination can independently justify omission of background sampling.
PSMA PET may have a more selective role. Its principal value is likely to be in men with equivocal or negative MRI despite persistent clinical suspicion, or in cases with discordant clinical and imaging findings. In the PRIMARY study, the addition of PSMA PET to mpMRI increased sensitivity and negative predictive value for clinically significant disease [41]. Combined molecular and anatomical imaging may identify patients in whom biopsy can be more accurately directed, although cost, availability, radiation exposure, and variable PSMA expression currently limit routine pre-biopsy use.
An integrated strategy should combine clinical risk, imaging confidence, and procedural confidence. Clinical risk includes PSA density, digital rectal examination, family history, age, and previous biopsy results. The EAU matrix links PI-RADS and PSA density: for PI-RADS 1–2, biopsy is generally omitted below 0.20 ng/mL/cc and considered above this threshold; for PI-RADS 3, biopsy is omitted below 0.10, considered at 0.10–0.15, strongly considered at 0.15–0.20, and performed above 0.20 ng/mL/cc [15]. These thresholds inform rather than replace the broader clinical assessment. Imaging confidence reflects lesion conspicuity, location, concordance across modalities, and technical quality, which can be assessed systematically with PI-QUAL version 2 [49]. Procedural confidence includes operator experience, targeting method, and expected needle-placement accuracy. Together, these domains should guide selection among targeted-only, targeted plus perilesional or ipsilateral, and targeted plus full systematic biopsy.
This framework is not a validated clinical algorithm and does not represent a guideline-endorsed standard of care. Evidence for reduced sampling is predominantly retrospective, definitions remain inconsistent, and direct comparisons of risk-adapted pathways are limited. Prospective trials should test predefined selection criteria rather than core counts alone, with preservation of clinically significant cancer detection and grading as the principal safety outcome. Figure 2 illustrates the proposed integration of clinical risk, mpMRI, imaging confidence, and biopsy extent.
Figure 2. Proposed risk-adapted biopsy pathway in suspected prostate cancer. The pathway integrates pre-biopsy mpMRI, clinical suspicion, PSA density, MRI quality, lesion characteristics, and targeting confidence to determine whether biopsy can be deferred and, when indicated, the extent of sampling. After negative MRI (PI-RADS 1–2), biopsy may be omitted with PSA monitoring when clinical suspicion is low (PSA-D < 0.20 ng/mL/cc and no family history); persistent high suspicion supports systematic biopsy. After PI-RADS 3, biopsy may be omitted only when suspicion is very low (PSA-D < 0.10 ng/mL/cc and no family history); otherwise, targeted biopsy with perilesional sampling should be considered. PI-RADS 4–5 lesions should undergo targeted biopsy with perilesional sampling. Additional regional, ipsilateral, or full systematic sampling should be individualised according to residual risk, imaging quality, lesion distribution, and targeting confidence. MicroUS and PSMA PET may refine selected problem-solving cases but are not routine substitutes for the MRI-directed pathway. This conceptual framework is informed by EAU 2026 recommendations; it has not been prospectively validated and does not represent a guideline-endorsed standard of care. Abbreviations: DRE, digital rectal examination; EAU, European Association of Urology; mpMRI, multiparametric magnetic resonance imaging; MRI, magnetic resonance imaging; microUS, micro-ultrasound; PET, positron emission tomography; PI-RADS, Prostate Imaging Reporting and Data System; PSA, prostate-specific antigen; PSA-D, prostate-specific antigen density; PSMA, prostate-specific membrane antigen.

9. Artificial Intelligence, Radiomics, and Future Directions

Artificial intelligence (AI) and radiomics may further refine prostate biopsy by extracting quantitative information that is not consistently captured through visual MRI interpretation alone. Radiomics converts imaging data into measurable features describing lesion intensity, shape, texture, and spatial heterogeneity. Machine-learning and deep-learning models can then combine these features with clinical variables such as prostate-specific antigen density, age, prostate volume, and PI-RADS score to estimate the probability of clinically significant prostate cancer [50,51,52].
The most immediate role of AI is decision support rather than autonomous diagnosis. It may assist lesion detection, reduce inter-reader variability, and improve assessment of equivocal findings, particularly PI-RADS 3 lesions. Multicentre studies report performance comparable to expert MRI interpretation, and combined imaging-clinical models may perform better than either data source alone [51,52,53]. In a prospective bicentre study, AI-assisted interpretation improved specificity while preserving high sensitivity, suggesting a potential reduction in false-positive MRI assessments [54].
Radiomics may also contribute to biopsy planning by estimating lesion aggressiveness before tissue sampling. Pooled evidence indicates high discriminatory performance for predicting Grade Group 2 or higher disease, although reported accuracy varies according to MRI sequences, segmentation method, reference standard, and validation strategy [55]. In principle, a high-risk quantitative signature could support more extensive targeted or regional sampling, whereas a low-risk and imaging-concordant lesion might justify a reduced-core approach.
Clinical implementation remains limited by retrospective, institution-specific models trained on relatively homogeneous datasets. Performance may decline across scanners, acquisition protocols, populations, and radiological workflows; manual segmentation and limited interpretability add further variability. External validation, calibration, prospective impact studies, and comparison with experienced radiologists are essential. PI-RADS Steering Committee reporting requirements reflect the need for transparent methods and clinically meaningful validation [56].
AI is best considered a risk-integration aid, not a replacement for radiologists or biopsy. Its clinical value depends on prospective evidence that it improves patient selection and safely reduces unnecessary cores without lowering clinically significant cancer detection. No published study discussed here tested an AI-defined reduction in core number; the PRIMER and AI-directed biopsy trials are among the first to address this question prospectively. Table 2 summarises representative evidence for established and emerging imaging-guided approaches.
Table 2. Key studies evaluating contemporary and emerging imaging-guided strategies for prostate cancer diagnosis and biopsy.

10. Evidence Gaps and Priorities for Future Research

Evidence remains insufficient to define a universally applicable limited-biopsy protocol because most perilesional, regional, and ipsilateral studies retrospectively reconstruct a reduced strategy from cores obtained during a complete combined biopsy [27,30,31]. Such analyses do not fully reproduce a prospectively planned limited procedure.
Terminology and methods also vary. Perilesional sampling may denote a fixed distance from the MRI target, adjacent sectors, or the entire ipsilateral lobe; studies further differ in biopsy route, targeting technique, core number, previous biopsy status, lesion characteristics, MRI quality, and definitions of clinically significant cancer. This heterogeneity limits comparison and prevents identification of an optimal safety margin [21,30,31].
Another unresolved issue is patient selection. The diagnostic consequences of reducing systematic biopsy may differ according to PSA density, PI-RADS category, lesion size and location, prostate volume, MRI quality, targeting confidence, and the presence of unilateral or multifocal disease. Prospective trials should evaluate predefined risk-adapted strategies instead of applying one reduced template to all MRI-positive patients.
Emerging modalities require the same scrutiny. MicroUS and PSMA PET show promising diagnostic performance, but systematic cores were retained in many studies, obscuring their independent contribution [40,41]. AI models likewise require external validation across scanners, institutions, and populations before they can guide biopsy extent. Another question is whether improved guidance accuracy with mechanical or robotic guidance could support further reduction in systematic sampling. Other emerging imaging approaches, including optoacoustic imaging, optical coherence tomography, fluorescence-based techniques, and hybrid optical–MRI methods, are also being investigated for lesion characterisation or biopsy guidance. At present, however, their clinical role continues to be uncertain [57,58].
Future research should prioritise multicentre prospective comparisons of targeted-only, targeted-plus-regional, and targeted-plus-systematic strategies using standardised definitions. Outcomes should include upgrading at prostatectomy, repeat biopsy, complications, procedure duration, cost-effectiveness, patient-reported outcomes, and long-term oncological safety, not cancer detection alone. Ongoing trials are evaluating perilesional and regional sampling, multimodal imaging, AI-assisted targeting, and risk-adapted pathways (Table 3).
Table 3. Selected ongoing and planned clinical trials evaluating imaging-guided and risk-adapted prostate biopsy strategies.
This review is narrative. Although a structured search and thematic selection criteria were used, there was no prospectively registered systematic-review protocol or formal risk-of-bias assessment. Study-selection and publication bias remain possible. In addition, the search for ongoing studies was limited to ClinicalTrials.gov, and trials registered exclusively in other international registries may therefore have been missed. Reference-list screening and prioritisation of prospective, multicentre, randomised, and pooled evidence reduced but did not eliminate this risk. The conclusions represent a critical narrative synthesis, not quantitative estimates from a formal systematic review.

11. Conclusions

Modern imaging has transformed prostate biopsy from a largely systematic procedure into a lesion-directed diagnostic pathway. Multiparametric MRI remains the central imaging modality, improving the detection of clinically significant prostate cancer while reducing unnecessary diagnosis of low-grade disease. Nevertheless, targeted biopsy alone does not eliminate the risk of missed or undergraded cancer, and additional sampling retains diagnostic value in selected patients.
The available evidence increasingly supports selective reduction, not universal omission of systematic biopsy. Perilesional, regional, and ipsilateral strategies may preserve most of the benefit of additional sampling while limiting unnecessary cores and clinically insignificant cancer detection. Micro-ultrasound and PSMA PET may further improve lesion localisation, whereas artificial intelligence could support risk integration and biopsy planning.
No single template is likely to suit every patient. Biopsy extent should be individualised according to clinical risk, imaging quality, lesion characteristics, and targeting confidence. Prospective multicentre validation remains necessary before reduced-sampling pathways can be adopted broadly.

Author Contributions

Conceptualisation, G.T. and C.K.; methodology, G.T. and D.D.; literature search, G.T., D.D. and S.L.; writing—original draft preparation, G.T.; writing—review and editing, D.D., S.L., D.M., S.G. and C.K.; visualisation, G.T.; supervision, S.G. and C.K. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Data Availability Statement

No new data were created or analysed in this study. Data sharing is not applicable to this article.

Acknowledgments

During manuscript preparation, ChatGPT (OpenAI, GPT-5.6) was used for language refinement. No data, results, analyses or references were generated by artificial intelligence. The authors have reviewed and edited the output and take full responsibility for the content of this publication.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Kasivisvanathan, V.; Rannikko, A.S.; Borghi, M.; Panebianco, V.; Mynderse, L.A.; Vaarala, M.H.; Briganti, A.; Budäus, L.; Hellawell, G.; Hindley, R.G.; et al. MRI-Targeted or Standard Biopsy for Prostate-Cancer Diagnosis. N. Engl. J. Med. 2018, 378, 1767–1777. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  2. Kasivisvanathan, V.; Stabile, A.; Neves, J.B.; Giganti, F.; Valerio, M.; Shanmugabavan, Y.; Clement, K.D.; Sarkar, D.; Philippou, Y.; Thurtle, D.; et al. Magnetic Resonance Imaging-Targeted Biopsy Versus Systematic Biopsy in the Detection of Prostate Cancer: A Systematic Review and Meta-Analysis. Eur. Urol. 2019, 76, 284–303. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  3. Elwenspoek, M.M.C.; Sheppard, A.L.; McInnes, M.D.F.; Merriel, S.W.D.; Rowe, E.W.J.; Bryant, R.J.; Donovan, J.L.; Whiting, P. Comparison of Multiparametric Magnetic Resonance Imaging and Targeted Biopsy with Systematic Biopsy Alone for the Diagnosis of Prostate Cancer: A Systematic Review and Meta-Analysis. JAMA Netw. Open 2019, 2, e198427. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  4. Rouvière, O.; Puech, P.; Renard-Penna, R.; Claudon, M.; Roy, C.; Mège-Lechevallier, F.; Decaussin-Petrucci, M.; Dubreuil-Chambardel, M.; Magaud, L.; Remontet, L.; et al. Use of Prostate Systematic and Targeted Biopsy on the Basis of Multiparametric MRI in Biopsy-Naive Patients (MRI-FIRST): A Prospective, Multicentre, Paired Diagnostic Study. Lancet Oncol. 2019, 20, 100–109. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  5. Ahdoot, M.; Wilbur, A.R.; Reese, S.E.; Lebastchi, A.H.; Mehralivand, S.; Gomella, P.T.; Bloom, J.; Gurram, S.; Siddiqui, M.; Pinsky, P.; et al. MRI-Targeted, Systematic, and Combined Biopsy for Prostate Cancer Diagnosis. N. Engl. J. Med. 2020, 382, 917–928. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  6. Miao, K.H.; Miao, J.H.; Finkelstein, M.; Chatterjee, A.; Oto, A. Next-Generation Advances in Prostate Cancer Imaging and Artificial Intelligence Applications. J. Imaging 2025, 11, 390. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  7. Bolocan, V.-O.; Mitoi, A.; Nicu-Canareica, O.; Băean, M.-L.; Medar, C.; Popa, G.-A. Artificial Intelligence in Prostate MRI: Current Evidence and Clinical Translation Challenges—A Narrative Review. J. Imaging 2025, 11, 335. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  8. Ahmed, H.U.; El-Shater Bosaily, A.; Brown, L.C.; Gabe, R.; Kaplan, R.; Parmar, M.K.; Collaco-Moraes, Y.; Ward, K.; Hindley, R.G.; Freeman, A.; et al. Diagnostic Accuracy of Multi-Parametric MRI and TRUS Biopsy in Prostate Cancer (PROMIS): A Paired Validating Confirmatory Study. Lancet 2017, 389, 815–822. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  9. Eklund, M.; Jäderling, F.; Discacciati, A.; Bergman, M.; Annerstedt, M.; Aly, M.; Glaessgen, A.; Carlsson, S.; Grönberg, H.; Nordström, T.; et al. MRI-Targeted or Standard Biopsy in Prostate Cancer Screening. N. Engl. J. Med. 2021, 385, 908–920. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  10. Nordström, T.; Discacciati, A.; Bergman, M.; Clements, M.; Aly, M.; Annerstedt, M.; Glaessgen, A.; Carlsson, S.; Jäderling, F.; Eklund, M.; et al. Prostate Cancer Screening Using a Combination of Risk-Prediction, MRI, and Targeted Prostate Biopsies (STHLM3-MRI): A Prospective, Population-Based, Randomised, Open-Label, Non-Inferiority Trial. Lancet Oncol. 2021, 22, 1240–1249. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  11. van der Leest, M.; Cornel, E.; Israël, B.; Hendriks, R.; Padhani, A.R.; Hoogenboom, M.; Zamecnik, P.; Bakker, D.; Setiasti, A.Y.; Veltman, J.; et al. Head-to-Head Comparison of Transrectal Ultrasound-Guided Prostate Biopsy Versus Multiparametric Prostate Resonance Imaging with Subsequent Magnetic Resonance-Guided Biopsy in Biopsy-Naïve Men with Elevated Prostate-Specific Antigen: A Large Prospective Multicenter Clinical Study. Eur. Urol. 2019, 75, 570–578. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  12. Klotz, L.; Chin, J.; Black, P.C.; Finelli, A.; Anidjar, M.; Bladou, F.; Mercado, A.; Levental, M.; Ghai, S.; Chang, S.D.; et al. Comparison of Multiparametric Magnetic Resonance Imaging–Targeted Biopsy with Systematic Transrectal Ultrasonography Biopsy for Biopsy-Naive Men at Risk for Prostate Cancer: A Phase 3 Randomized Clinical Trial. JAMA Oncol. 2021, 7, 534–542. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  13. Drost, F.-J.H.; Osses, D.F.; Nieboer, D.; Steyerberg, E.W.; Bangma, C.H.; Roobol, M.J.; Schoots, I.G. Prostate MRI, with or without MRI-Targeted Biopsy, and Systematic Biopsy for Detecting Prostate Cancer. Cochrane Database Syst. Rev. 2019, 4, CD012663. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  14. Padhani, A.R.; Barentsz, J.; Villeirs, G.; Rosenkrantz, A.B.; Margolis, D.J.; Turkbey, B.; Thoeny, H.C.; Cornud, F.; Haider, M.A.; Macura, K.J.; et al. PI-RADS Steering Committee: The PI-RADS Multiparametric MRI and MRI-Directed Biopsy Pathway. Radiology 2019, 292, 464–474. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  15. EAU. Guidelines on Prostate Cancer—Uroweb. Available online: https://uroweb.org/guidelines/prostate-cancer (accessed on 7 July 2026).
  16. Erbin, A.; Caglar, U.; Turkay, R. Evaluating the Effectiveness and Safety of Robotic-Assisted MRI/TRUS Fusion Transperineal Prostate Biopsy Systems: A Narrative Review Based on Current Literature. Eurasian J. Med. 2023, 55, S125–S130. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  17. Elkhoury, F.F.; Felker, E.R.; Kwan, L.; Sisk, A.E.; Delfin, M.; Natarajan, S.; Marks, L.S. Comparison of Targeted vs Systematic Prostate Biopsy in Men Who Are Biopsy Naive: The Prospective Assessment of Image Registration in the Diagnosis of Prostate Cancer (PAIREDCAP) Study. JAMA Surg. 2019, 154, 811–818. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  18. Deng, R.; Shang, J.; Wu, J.; Tian, S.; Li, D.; Shen, Q.; Hu, S.; Shang, M.; Qiu, J.; Zhou, J.; et al. A Head-to-Head Comparison of Sextant-Systematic Biopsy vs. Extended-Systematic Biopsy for Prostate Cancer Diagnosis in the Era of MRI-Targeted Biopsy: SEXTANT-PRO Non-Inferiority Randomized Clinical Trial. eClinicalMedicine 2025, 90, 103630. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  19. Bourgeno, H.-A.; Jabbour, T.; Baudewyns, A.; Lefebvre, Y.; Ferriero, M.; Simone, G.; Fourcade, A.; Fournier, G.; Oderda, M.; Gontero, P.; et al. The Added Value of Side-Specific Systematic Biopsy in Patients Diagnosed by Magnetic Resonance Imaging–Targeted Prostate Biopsy. Eur. Urol. Oncol. 2024, 7, 1320–1326. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  20. Brisbane, W.G.; Priester, A.M.; Ballon, J.; Kwan, L.; Delfin, M.K.; Felker, E.R.; Sisk, A.E.; Hu, J.C.; Marks, L.S. Targeted Prostate Biopsy: Umbra, Penumbra, and Value of Perilesional Sampling. Eur. Urol. 2022, 82, 303–310. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  21. Noujeim, J.-P.; Belahsen, Y.; Lefebvre, Y.; Lemort, M.; Deforche, M.; Sirtaine, N.; Martin, R.; Roumeguère, T.; Peltier, A.; Diamand, R. Optimizing Multiparametric Magnetic Resonance Imaging-Targeted Biopsy and Detection of Clinically Significant Prostate Cancer: The Role of Perilesional Sampling. Prostate Cancer Prostatic Dis. 2023, 26, 575–580. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  22. Bryk, D.J.; Llukani, E.; Taneja, S.S.; Rosenkrantz, A.B.; Huang, W.C.; Lepor, H. The Role of Ipsilateral and Contralateral Transrectal Ultrasound-Guided Systematic Prostate Biopsy in Men with Unilateral Magnetic Resonance Imaging Lesion Undergoing Magnetic Resonance Imaging-Ultrasound Fusion-Targeted Prostate Biopsy. Urology 2017, 102, 178–182. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  23. Freifeld, Y.; Xi, Y.; Passoni, N.; Woldu, S.; Hornberger, B.; Goldberg, K.; Bagrodia, A.; Raj, G.; Margulis, V.; Cadeddu, J.A.; et al. Optimal Sampling Scheme in Men with Abnormal Multiparametric MRI Undergoing MRI-TRUS Fusion Prostate Biopsy. Urol. Oncol. 2019, 37, 57–62. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  24. Jager, A.; van Riel, L.A.M.J.G.; Postema, A.W.; de Reijke, T.M.; van der Sluis, T.M.; Oddens, J.R. An Optimized Prostate Biopsy Strategy in Patients with a Unilateral Lesion on Prostate Magnetic Resonance Imaging Avoids Unnecessary Biopsies. Ther. Adv. Urol. 2022, 14, 17562872221111410. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  25. Ruan, M.; Wang, H.; Li, X.; Song, G. Novel Sampling Scheme with Reduced Cores in Men with Multiparametric MRI-Visible Lesions Undergoing Prostate Biopsy. Abdom. Radiol. 2023, 48, 2139–2147. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  26. Yu, L.-P.; Du, Y.-Q.; Sun, Y.-R.; Qin, C.-P.; Yang, W.-B.; Huang, Z.-X.; Xu, T. Value of Cognitive Fusion Targeted and Standard Systematic Transrectal Prostate Biopsy for Prostate Cancer Diagnosis. Asian J. Androl. 2024, 26, 479–483. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  27. Hagens, M.J.; Noordzij, M.A.; Mazel, J.W.; Jager, A.; Boellaard, T.N.; Tielbeek, J.A.W.; Henebiens, M.; Schoots, I.G.; van Leeuwen, P.J.; van der Poel, H.G.; et al. An Magnetic Resonance Imaging-Directed Targeted-plus-Perilesional Biopsy Approach for Prostate Cancer Diagnosis: “Less Is More.”. Eur. Urol. Open Sci. 2022, 43, 68–73. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  28. Duwe, G.; Schmitteckert, M.; Haack, M.; Sparwasser, P.; Dotzauer, R.; Thomas, A.; Tsaur, I.; Brandt, M.P.; Kurosch, M.; Mager, R.; et al. Value of Perilesional Biopsies in Multiparametric Magnetic Resonance Imaging-Targeted Biopsy and Systematic Biopsy in Detection of Prostate Cancer: Results of a Prospective, Non-Randomized, Surgeon-Blinded Study. World J. Urol. 2024, 42, 297. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  29. Jiang, X.; Chen, M.; Tian, J.; Li, X.; Liu, R.; Wang, Y.; Zhao, Y.; Peng, S.; Niu, Y.; Xu, Y. Comparison of Regional Saturation Biopsy, Targeted Biopsy, and Systematic Biopsy in Patients with Prostate-Specific Antigen Levels of 4-20 Ng/Ml: A Prospective, Single-Center, Randomized Controlled Trial. Eur. Urol. Oncol. 2024, 7, 944–953. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  30. Hagens, M.J.; Fernandez Salamanca, M.; Padhani, A.R.; van Leeuwen, P.J.; van der Poel, H.G.; Schoots, I.G. Diagnostic Performance of a Magnetic Resonance Imaging-Directed Targeted plus Regional Biopsy Approach in Prostate Cancer Diagnosis: A Systematic Review and Meta-Analysis. Eur. Urol. Open Sci. 2022, 40, 95–103. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  31. Sanguedolce, F.; Lauwers, C.N.G.; Tedde, A.; Basile, G.; Chernysheva, D.; Uleri, A.; Baboudjian, M.; Giannarini, G.; Panebianco, V.; Madonia, M.; et al. Regional Versus Systematic Biopsy in Addition to Targeted Biopsy: Results from a Systematic Review and Meta-Analysis. Eur. Urol. Oncol. 2025, 8, 534–543. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  32. Wu, Q.; Wang, J.; Tu, X.; Chen, B.; Jiang, J.; Ye, J.; Zheng, L.; He, C.; Tang, B.; Bao, Y.; et al. Optimizing the Strategies to Perform Prostate Biopsy in MRI-Positive Patients: A Systematic Review and Network Meta-Analysis. eClinicalMedicine 2025, 82, 103164. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  33. Lin, D.W.; Carlsson, S.; Filson, C.P.; Kim, S.K.; Kirkby, E.; Konety, B.R.; Purysko, A.S.; Souter, L.H. Updates to Early Detection of Prostate Cancer: AUA/SUO Guideline (2026). J. Urol. 2026, 215, 491–501. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  34. Hu, J.C.; Assel, M.; Allaf, M.E.; Ehdaie, B.; Vickers, A.J.; Cohen, A.J.; Ristau, B.T.; Green, D.A.; Han, M.; Rezaee, M.E.; et al. Transperineal Versus Transrectal Magnetic Resonance Imaging–Targeted and Systematic Prostate Biopsy to Prevent Infectious Complications: The PREVENT Randomized Trial. Eur. Urol. 2024, 86, 61–68. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  35. Basso Dias, A.; Ghai, S. Micro-Ultrasound: Current Role in Prostate Cancer Diagnosis and Future Possibilities. Cancers 2023, 15, 1280. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  36. Dias, A.B.; Ghai, S. Prostate Cancer Diagnosis with Micro-Ultrasound: What We Know Now and New Horizons. Radiol. Clin. N. Am. 2024, 62, 189–197. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  37. Klotz, L.; Lughezzani, G.; Maffei, D.; Sánchez, A.; Pereira, J.G.; Staerman, F.; Cash, H.; Luger, F.; Lopez, L.; Sanchez-Salas, R.; et al. Comparison of Micro-Ultrasound and Multiparametric Magnetic Resonance Imaging for Prostate Cancer: A Multicenter, Prospective Analysis. Can. Urol. Assoc. J. 2021, 15, E11–E16. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  38. Sountoulides, P.; Pyrgidis, N.; Polyzos, S.A.; Mykoniatis, I.; Asouhidou, E.; Papatsoris, A.; Dellis, A.; Anastasiadis, A.; Lusuardi, L.; Hatzichristou, D. Micro-Ultrasound-Guided vs Multiparametric Magnetic Resonance Imaging-Targeted Biopsy in the Detection of Prostate Cancer: A Systematic Review and Meta-Analysis. J. Urol. 2021, 205, 1254–1262. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  39. Dariane, C.; Ploussard, G.; Barret, E.; Beauval, J.-B.; Brureau, L.; Créhange, G.; Fromont, G.; Gauthé, M.; Mathieu, R.; Renard-Penna, R.; et al. Micro-Ultrasound-Guided Biopsies versus Systematic Biopsies in the Detection of Prostate Cancer: A Systematic Review and Meta-Analysis. World J. Urol. 2023, 41, 641–651. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  40. Kinnaird, A.; Luger, F.; Cash, H.; Ghai, S.; Urdaneta-Salegui, L.F.; Pavlovich, C.P.; Brito, J.; Shore, N.D.; Struck, J.P.; Schostak, M.; et al. Microultrasonography-Guided vs MRI-Guided Biopsy for Prostate Cancer Diagnosis: The OPTIMUM Randomized Clinical Trial. JAMA 2025, 333, 1679–1687. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  41. Emmett, L.; Buteau, J.; Papa, N.; Moon, D.; Thompson, J.; Roberts, M.J.; Rasiah, K.; Pattison, D.A.; Yaxley, J.; Thomas, P.; et al. The Additive Diagnostic Value of Prostate-Specific Membrane Antigen Positron Emission Tomography Computed Tomography to Multiparametric Magnetic Resonance Imaging Triage in the Diagnosis of Prostate Cancer (PRIMARY): A Prospective Multicentre Study. Eur. Urol. 2021, 80, 682–689. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  42. Emmett, L.M.; Papa, N.; Buteau, J.; Ho, B.; Liu, V.; Roberts, M.; Thompson, J.; Moon, D.; Sheehan-Dare, G.; Alghazo, O.; et al. The PRIMARY Score: Using Intra-Prostatic PSMA PET/CT Patterns to Optimise Prostate Cancer Diagnosis. J. Nucl. Med. 2022, 63, 1644–1650. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  43. Buteau, J.P.; Moon, D.; Fahey, M.T.; Roberts, M.J.; Ayati, N.; Papa, N.; Murphy, D.G.; Kasivisvanathan, V.; Dhillon, H.M.; Du, Y.T.; et al. Effect of [68Ga]Ga-PSMA-11 PET-CT in the Diagnosis of Prostate Cancer in Men with Equivocal or Clinically High-Risk Non-Suspicious Findings on Multiparametric MRI (PRIMARY2): A Multicentre, Non-Inferiority, Phase 3, Randomised Controlled Trial. Lancet Oncol. 2026, 27, 839–848. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  44. Wong, L.-M.; Sutherland, T.; Perry, E.; Tran, V.; Spelman, T.; Corcoran, N.; Lawrentschuk, N.; Woo, H.; Lenaghan, D.; Buchan, N.; et al. Fluorine-18-Labelled Prostate-Specific Membrane Antigen Positron Emission Tomography/Computed Tomography or Magnetic Resonance Imaging to Diagnose and Localise Prostate Cancer. A Prospective Single-Arm Paired Comparison (PEDAL). Eur. Urol. Oncol. 2024, 7, 1015–1023. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  45. Kawada, T.; Yanagisawa, T.; Rajwa, P.; Sari Motlagh, R.; Mostafaei, H.; Quhal, F.; Laukhtina, E.; Aydh, A.; König, F.; Pallauf, M.; et al. Diagnostic Performance of Prostate-Specific Membrane Antigen Positron Emission Tomography-Targeted Biopsy for Detection of Clinically Significant Prostate Cancer: A Systematic Review and Meta-Analysis. Eur. Urol. Oncol. 2022, 5, 390–400. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  46. Aggarwal, P.; Gunasekaran, V.; Singh, H.; Kumar, R.; Satapathy, S.; Mittal, B.R. Diagnostic Accuracy of PSMA PET-Guided Prostate Biopsy in Prostate Cancer-A Systematic Review and Meta-Analysis. Clin. Nucl. Med. 2025, 50, e26–e33. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  47. Chow, K.M.; Lee, A.; Peh, D.; Tan, Y.G.; Tay, K.J.; Ho, H.; Cheng, C.; Lam, W.; Thang, S.P.; Tuan, J.; et al. Combined Prostate-Specific Membrane Antigen Positron Emission Tomography and Multiparametric Magnetic Resonance Imaging for the Diagnosis of Clinically Significant Prostate Cancer. Eur. Urol. Oncol. 2025, 8, 1393–1405. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  48. Mazzone, E.; Cannoletta, D.; Quarta, L.; Chen, D.C.; Thomson, A.; Barletta, F.; Stabile, A.; Moon, D.; Eapen, R.; Lawrentschuk, N.; et al. A Comprehensive Systematic Review and Meta-Analysis of the Role of Prostate-Specific Membrane Antigen Positron Emission Tomography for Prostate Cancer Diagnosis and Primary Staging before Definitive Treatment. Eur. Urol. 2025, 87, 654–671. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  49. De Rooij, M.; Allen, C.; Twilt, J.J.; Thijssen, L.C.P.; Asbach, P.; Barrett, T.; Brembilla, G.; Emberton, M.; Gupta, R.T.; Haider, M.A.; et al. PI-QUAL Version 2: An Update of a Standardised Scoring System for the Assessment of Image Quality of Prostate MRI. Eur. Radiol. 2024, 34, 7068–7079. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  50. Castillo, T.J.M.; Arif, M.; Niessen, W.J.; Schoots, I.G.; Veenland, J.F. Automated Classification of Significant Prostate Cancer on MRI: A Systematic Review on the Performance of Machine Learning Applications. Cancers 2020, 12, 1606. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  51. Zhao, L.; Bao, J.; Qiao, X.; Jin, P.; Ji, Y.; Li, Z.; Zhang, J.; Su, Y.; Ji, L.; Shen, J.; et al. Predicting Clinically Significant Prostate Cancer with a Deep Learning Approach: A Multicentre Retrospective Study. Eur. J. Nucl. Med. Mol. Imaging 2023, 50, 727–741. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  52. Roest, C.; Yakar, D.; Rener Sitar, D.I.; Bosma, J.S.; Rouw, D.B.; Fransen, S.J.; Huisman, H.; Kwee, T.C. Multimodal AI Combining Clinical and Imaging Inputs Improves Prostate Cancer Detection. Invest. Radiol. 2024, 59, 854–860. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  53. Yang, C.; Li, B.; Luan, Y.; Wang, S.; Bian, Y.; Zhang, J.; Wang, Z.; Liu, B.; Chen, X.; Hacker, M.; et al. Deep Learning Model for the Detection of Prostate Cancer and Classification of Clinically Significant Disease Using Multiparametric MRI in Comparison to PI-RADs Score. Urol. Oncol. 2024, 42, 158.e17–158.e27. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  54. Lee, Y.J.; Moon, H.W.; Choi, M.H.; Eun Jung, S.; Park, Y.H.; Lee, J.Y.; Kim, D.H.; Eun Rha, S.; Kim, S.H.; Lee, K.W.; et al. MRI-Based Deep Learning Algorithm for Assisting Clinically Significant Prostate Cancer Detection: A Bicenter Prospective Study. Radiology 2025, 314, e232788. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  55. Lomer, N.B.; Ashoobi, M.A.; Ahmadzadeh, A.M.; Sotoudeh, H.; Tabari, A.; Torigian, D.A. MRI-Based Radiomics for Predicting Prostate Cancer Grade Groups: A Systematic Review and Meta-Analysis of Diagnostic Test Accuracy Studies. Acad. Radiol. 2025, 32, 3429–3452. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  56. Turkbey, B.; Huisman, H.; Fedorov, A.; Macura, K.J.; Margolis, D.J.; Panebianco, V.; Oto, A.; Schoots, I.G.; Siddiqui, M.M.; Moore, C.M.; et al. Requirements for AI Development and Reporting for MRI Prostate Cancer Detection in Biopsy-Naive Men: PI-RADS Steering Committee, Version 1.0. Radiology 2025, 315, e240140. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  57. Chen, Z.; Gezginer, I.; Zhou, Q.; Tang, L.; Deán-Ben, X.L.; Razansky, D. Multimodal Optoacoustic Imaging: Methods and Contrast Materials. Chem. Soc. Rev. 2024, 53, 6068–6099. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  58. Tajaldeen, A.; Alrashidi, M.; Alsaadi, M.J.; Alghamdi, S.S.; Alshammari, H.; Alsleem, H.; Jafer, M.; Aljondi, R.; Alqahtani, S.; Alotaibi, A.; et al. Photoacoustic Imaging in Prostate Cancer: A New Paradigm for Diagnosis and Management. Photodiagnosis Photodyn. Ther. 2024, 47, 104225. [Google Scholar] [CrossRef] [Scilit] [PubMed]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.