Review Reports
- Pavlo Kuznietsov *,
- Viktor Moshynskyi and
- Serhii Martynov
- et al.
Reviewer 1: Anonymous Reviewer 2: Anonymous Reviewer 3: Anonymous
Round 1
Reviewer 1 Report
Comments and Suggestions for Authors- Table 2 appeared multiple times making the numbering and referencing inconsistent (line 243, line 254)
- Table 2, LSI table; lines 224–234: The measured hardness rises then falls (peaking at CF = 4 and dropping to 1.00 mmol/L at CF = 7), and Ca²⁺ in the LSI/RSI tables mirrors this rise-and-fall pattern, yet the mechanism is only asserted, not evidenced. The authors could clarify whether this reflects CaCO₃ precipitation, and then state it explicitly, since a dataset descriptor must let users interpret the non-monotonic trend.
- line 230: ΔTH at CF = 7 is stated as "6.35" in the text, but "6.25" in the table 2
- line 240: typo: line 86,39%, please use 86.39%
- line 239: CPI is written as "68.5%" in the text, but "68.25" in Table 2,
- LSI and RSI are reported only as means (lines 254, 265) despite ten replicates being collected, and Figure 2 (line 291) plots single values without error bars or reference to the underlying replicate spread.
Author Response
We sincerely thank the reviewer for the careful and thorough evaluation of our manuscript. We particularly appreciate the reviewer’s close attention to the numerical values, internal consistency of the tables and text, and presentation of the replicate measurements. These detailed observations were very valuable in identifying several inconsistencies and improving the clarity, accuracy, and scientific transparency of the manuscript. We have carefully considered all comments and revised the manuscript accordingly. All changes made in response to the reviewer’s comments are highlighted with green shading in the revised manuscript.
Comment 1 Table 2, LSI table; lines 224–234: The measured hardness rises then falls (peaking at CF = 4 and dropping to 1.00 mmol/L at CF = 7), and Ca²⁺ in the LSI/RSI tables mirrors this rise-and-fall pattern, yet the mechanism is only asserted, not evidenced. The authors could clarify whether this reflects CaCO₃ precipitation, and then state it explicitly, since a dataset descriptor must let users interpret the non-monotonic trend. Response: We sincerely thank the reviewer for this careful observation and valuable suggestion. We have clarified the interpretation of the non-monotonic hardness trend and now state that the observed pattern is consistent with the removal of hardness-forming constituents from the aqueous phase, potentially through mineral precipitation. CaCO₃ precipitation is identified as a plausible mechanism, while explicitly acknowledging that the precipitated phase was not directly characterized. The revised text is highlighted with green shading in the manuscript.
Comment 2 line 230: ΔTH at CF = 7 is stated as "6.35" in the text, but "6.25" in the table 2 Response: We thank the reviewer for carefully checking the numerical consistency of the manuscript. This discrepancy has been corrected, and the value of ΔTH at CF = 7 is now consistently reported as 6.25 mmol/L in both the text and Table 2. The correction is highlighted with green shading.
Comment 3 line 240: typo: line 86,39%, please use 86.39% Response: Thank you for identifying this typographical error. The value has been corrected to 86.39%. The correction is highlighted with green shading.
Comment 4 line 239: CPI is written as "68.5%" in the text, but "68.25" in Table 2, Response: We greatly appreciate the reviewer’s careful attention to the numerical details. The inconsistency has been corrected, and the CPI value is now reported consistently as 68.25% in both the text and Table 2. The correction is highlighted with green shading.
Comment 5 LSI and RSI are reported only as means (lines 254, 265) despite ten replicates being collected, and Figure 2 (line 291) plots single values without error bars or reference to the underlying replicate spread. Response: We thank the reviewer for this important observation regarding the presentation of replicate measurements. We have revised the LSI and RSI results to report the values as mean ± SD, based on the ten replicate measurements. The corresponding numerical values and their variability are now explicitly provided in the revised text.
Reviewer 2 Report
Comments and Suggestions for AuthorsMy impression is that the idea is interesting and potentially publishable, but in its current form, the paper has some significant methodological issues that, in my opinion, the authors should address before publication. Major revisions should be made.
The main problem is that the CPI is not truly validated as a scaling indicator. The manuscript proposes the Concentration–Hardness Precipitation Index (CPI) as the primary indicator of precipitation risk. The problem is that a decrease in hardness relative to what is theoretically expected does not in itself prove that CaCO₃ has formed or that scaling has occurred. It may also be due to other processes. The authors themselves admit, in Appendix D, that the CPI does not directly measure the amount of deposit but identifies a deviation from the theoretical concentration. I would suggest avoiding directly referring to the CPI as a “scaling” index unless it is validated against an independent measure of deposit, and instead defining it as a screening indicator of hardness depletion or precipitation tendency;
To validate these findings, the authors should directly measure the mass of the deposit, characterize the deposit—for example, using SEM/EDS, XRD, or at least chemical analysis of the solid—and correlate the CPI with an independent measurement of the precipitation. In this regard, I suggest comparing the results with CaCO₃ data from the literature. This is useful for comparing the XRD spectra and, using SEM, observing the diversity of the crystals and how they form.
The experimental setup essentially consists of a tank, a pump, and a heater, with concentration achieved through controlled evaporation. The authors acknowledge that it does not replicate all the processes of a real plant. This is perfectly acceptable for a proof-of-concept, but the manuscript sometimes tends to generalize the results to industrial systems or nuclear power plants (NPPs). The authors correctly mention some of these factors at the beginning, but then the experimental validation essentially considers only one type of water and a single matrix. The authors should explicitly add a “Limitations” section, and I would tone down the conclusions regarding applicability. Even better, they should conduct a second validation using water with different compositions, different initial hardness levels, different alkalinities, and possibly water containing the additives normally present in the circuit, as well as real samples collected at different operational times.
Test B is a visual and discrete system. The authors themselves admit that different TH values can produce the same color category. Yet the paper uses Pearson correlation as its primary validation evidence. This is weak because the method does not actually produce a continuous variable: it produces a category or interval estimate. The authors should therefore report, in addition to the correlation: mean error per category; percentage of results within ± one category; concordance matrix; and uncertainty associated with each class.
The methodology section states, “The experiment was repeated 10 times, yielding 10 independent series of measurements.” However, the dataset description mentions “seven experimental series and ten concentration levels within each series,” while the validation tables show seven levels. This discrepancy must be clarified. The authors should clearly explain how many independent experiments were conducted, how many samples there were for each CF, how many Test A measurements per sample, how many Test B measurements, how many ISO measurements, which data represent technical replicates and which represent biological/experimental replicates, and which n was actually used to calculate r and R².
In the main text, for CF = 4, THexp = 4.20, but in Appendix D, for CF = 4, examples with THexp = 5.0 mmol/L are used. Similarly, values of THexp = 7, 10, and 15 mmol/L appear for CF 5–7. This table in Appendix D is inconsistent with the equation and the experimental dataset. The authors must explain whether Appendix D is a purely theoretical/illustrative table or a table derived from the experiment. If it is theoretical, it must be explicitly labeled as such and separated from the experimental data. If, on the other hand, it is intended to represent the experimental data, it must be corrected.
The description of CF = 7 also contains a numerical inconsistency: the text states that at CF = 7, ΔTH = 6.35 mmol/L, but the previous sentence also mentions a value of 6.25; the table lists 6.25. Therefore, Table 2, the CPI, and the text must be corrected consistently.
The paper is defined as a Data Descriptor, but a significant portion of the manuscript is devoted to interpreting the results almost as if it were a research article.
The authors should place greater emphasis on what exactly is in the dataset. The structure of the six worksheets is already described in the manuscript, but it would be helpful to make it much more quantitative and reproducible.
Important information regarding the reproducibility of the paper-based test is missing; the authors should include details such as disk size, amount of immobilized reagent per unit area, batch-to-batch consistency, shelf life, storage conditions, stability after 1, 3, 6, 12 months, the effect of humidity, the effect of light, inter-operator variability, variability in visual reading, and any chromatic interference from the matrix.
The data reveal an interesting phenomenon that the authors should investigate further. There is one aspect that, in my opinion, could even make the paper more interesting. As CF increases, hardness rises up to CF4 and then decreases. At the same time, Ca²⁺ decreases from approximately 84 mg/L at CF4 to approximately 21 mg/L at CF7, while pH rises to 8.99. This is consistent with the precipitation hypothesis, but precisely because it is the most interesting result, it should be demonstrated, not merely inferred. If the authors could show that the precipitated material is indeed calcium carbonate, the work would become much more convincing.
The manuscript suggests that the system could help reduce blowdown and makeup water and thus support circular water management. While this is a reasonable prospect, it has not actually been demonstrated experimentally. I would therefore suggest rephrasing these sentences to shift the focus from an experimental claim to a potential application.
Author Response
We sincerely thank the reviewer for the careful and constructive assessment of our manuscript. We greatly appreciate the detailed methodological comments, which helped us improve the scientific rigor and clarity of the Data Descriptor. All corresponding revisions are highlighted in yellow in the revised manuscript. For clarity, the reviewer’s comments are reproduced below, followed by our responses.
Comment 1 The main problem is that the CPI is not truly validated as a scaling indicator... Response: Thank you for this important comment. We agree and have revised the terminology throughout the manuscript. CPI is now defined as a screening indicator of hardness depletion and potential precipitation tendency, rather than as a direct scaling index. We also explicitly state that CPI does not directly quantify deposited material or prove CaCO₃ scale formation.
Comment 2 To validate these findings, the authors should directly measure the mass of the deposit... Response: We fully agree that direct characterization of the precipitated material would strengthen the validation. However, such measurements were not included in the present experimental design. We have therefore added this point to the Limitations and Future Work section and specified gravimetric analysis, SEM/EDS, XRD, and correlation of CPI with independent precipitation measurements as priorities for future research.
Comment 3 The experimental setup essentially consists of a tank, a pump, and a heater... Response: Thank you. We have added a Limitations section describing the laboratory-scale setup, the use of a single water matrix, and the limited representation of industrial operating conditions. We have also moderated the conclusions concerning applicability to industrial cooling systems and NPPs. Further validation using waters with different hardness, alkalinity, ionic composition, additives, and operational histories is identified as future work.
Comment 4 Test B is a visual and discrete system... Response: We agree. In addition to Pearson’s correlation, we have added mean absolute error, bias, exact categorical agreement, percentage of results within ±1 category, and a concordance/confusion matrix for Test B (Appendix Е). We also report the variability of the reference measurements and explicitly distinguish it from the measurement uncertainty of the paper-based test. Pearson correlation is now described as a descriptive measure of association, rather than the sole validation criterion.
Comment 5 The methodology section states, “The experiment was repeated 10 times...” However, the dataset description mentions “seven experimental series...” Response: Thank you for identifying this inconsistency. We have revised the description of the experimental design and dataset structure to clarify the number of concentration levels, replicates, and measurements. The terminology concerning experimental replicates and repeated measurements has also been made consistent throughout the manuscript. The values of \(n\) used for the validation statistics are now explicitly stated.
Comment 6 In the main text, for CF = 4, THexp = 4.20, but in Appendix D... Response: We agree. Table D.1 was intended only as a theoretical/illustrative example of CPI calculation and was not derived from the experimental dataset. We have explicitly labeled it as a hypothetical illustrative table and added a clarification that its values must not be interpreted as experimental observations. The experimental CPI data remain presented separately in Table 2.
Comment 7 The description of CF = 7 also contains a numerical inconsistency... Response: Thank you for pointing this out. The inconsistency has been corrected. The corresponding CPI value has also been checked and corrected consistently.
Comment 8 The paper is defined as a Data Descriptor, but a significant portion of the manuscript is devoted to interpreting the results almost as if it were a research article. Response: We agree with this observation. The manuscript has been revised to place greater emphasis on dataset structure, measurement procedures, technical validation, reproducibility, and data reuse, while reducing interpretative statements that extend beyond the scope of a Data Descriptor.
Comment 9 The authors should place greater emphasis on what exactly is in the dataset... Response: Thank you. We have strengthened the description of the procedures used to generate and validate the dataset.
Comment 10 Important information regarding the reproducibility of the paper-based test is missing... Response: We appreciate this important recommendation. We have added the available information on paper characteristics, reagent immobilization, drying, storage, light protection, and desiccant use. Parameters that were not experimentally evaluated, including long-term stability, humidity effects, batch-to-batch variability, inter-operator variability, and chromatic interference, are now explicitly identified as limitations and priorities for future validation rather than being inferred from the available data.
Comment 11 The data reveal an interesting phenomenon... If the authors could show that the precipitated material is indeed calcium carbonate... Response: We thank the reviewer for highlighting this important aspect of the dataset. We agree that the observed decrease in dissolved Ca²⁺ and hardness at higher CF values, together with increasing pH and LSI, is consistent with a precipitation-related process. However, because the precipitated phase was not collected and characterized, we have avoided presenting CaCO₃ formation as experimentally demonstrated. The manuscript now explicitly states this limitation and identifies SEM/EDS, XRD, and chemical characterization of the precipitate as necessary follow-up analyses.
Comment 12 The manuscript suggests that the system could help reduce blowdown and makeup water... Response: We agree. The relevant statements have been revised to describe reduced blowdown and make-up water demand as a potential application rather than an experimentally demonstrated outcome. We now explicitly state that reductions in water consumption were not evaluated in the present study.
Reviewer 3 Report
Comments and Suggestions for AuthorsDear Authors,
The article "Experimental Dataset for Rapid Monitoring of Concentration and Scaling Tendency in Recirculating Cooling Water Using Paper-Based Colorimetric Tests”
is dealing with a paper-based colorimetric approach from rapid monitoring of the concentration and scaling conditions in recirculation cooling water of a nuclear power plant, using a laboratory –scale installation for simulation. Paper-based colorimetric Cl- and total hardness measurements and other experimental data were used to calculate CF, CPI, LSI and RSI parameters to evaluate and screen the scaling tendency in recirculation cooling water systems.
However, there are still several issues which require a revision of the manuscript. If authors are willing to perform an in-depth revision the manuscript can be reconsidered for publication. I do not recommend publication of this manuscript in its current form.
A list with general comments and concerns and a detailed list of comments and questions is addressed to the authors.
List with general comments and concerns
- The manuscript contains many duplicates without added value and should be condensed and shortened considerably. It is recommended to omit or merge these duplicates and focus on the outcome and novelty of the manuscript (See detailed list of comment and questions).
- Numbering of the Tables is not correct and should be revised (See detailed list of comment and questions).
- Tables of worksheets are not in line with Tables in the manuscript.
- There is severe overlap between Appendices and several paragraphs in the manuscript which should be merged (See detailed list of comment and questions).
- Number of significant figures of standard deviations and mean should be the same (See detailed list of comment and questions).
Detailed list of comments and questions.
Keywords
It is suggestion to include chloride as key word and "recirculation cooling water" and merge "recirculation cooling water" and" circular water management" into one keyword: "merge "recirculation cooling water management". Please comment.
- Data description
Lines 96-104: Sheet/worksheet 2 is identical to Table 1 (Lines 208-209). Please comment.
Line 138: Dimensions of the discs? Please comment.
Lines 144-145: Response of model chloride concentration of 0 mg/L Cl- is missing in Fig.1. Please comment.
Line 145-147: What is the chloride concentration of the NaCl stock solution? Please comment.
Lines 150-151: Response of model TH concentration of 0 mmol/L is missing in Fig.1. Please comment.
Lines 153-154: What is the CaCO3 concentration of the stock solution? Please comment.
Lines 157-158: Colorimetric values for 0 mg/L Cl- and TH value of 0 mmol/L are missing in Fig.1. Please comment.
Lines 180-185: Are duplicates of previous lines and should be omitted. Please comment.
Lines 194-196: Number of significant figures of standard deviations and mean should be the same: e.g. "3.36 ± 0.34" instead of "3.36 ± 0.336". Please comment.
Line 203: CF value of 1.0 is not found in Table 1. Please comment.
Lines 205-207: These lines are duplicates of lines 191-194 and lines 199-201 without added value and should be omitted. Please comment.
Lines 208-209: Number of significant figures of standard deviations and mean should be the same in Table 1: E.g.: "70.40 ± 7.00" instead of "70.4 ± 7.00". Please comment.
Lines 208-209: Number of significant figures of standard deviations and mean should be the same in Table 1: E.g.: "70.40 ± 7.00" instead of "70.4 ± 7.00". Please comment.
Lines 210-213: These lines are duplicates of previous without added value and should be omitted. Please comment.
Line 220: Numbering of Tables is not correct. Reference is made twice to Table 2 (p.6 and p.7) which is confusing when reading the discussions on p.6-7. Please comment.
In addition, Tables 2-4 are duplicates of sheet/worksheet 3-4 (Table 4b) - 5 (Table 5b)- 6. Please comment.
Line 239: "68.25%" instead of "68.5%" according to Table 2 on p.6. Please comment.
Line 245: Numbering of Tables should be revised. Please comment.
Line 254, Table 2: "CaI+" should be replaced by "Ca2+". Please comment. Too many significant figures for Ca2+, TA, TDS and pHs. Please comment. Which experimental precautions have been taken to report pH values at the 0.001 level? Please comment.
Line 265, Table 3: "CaI+" should be replaced by "Ca2+". Please comment. Too many significant figures for TA. Please comment. Why Ca2+, TA and pHs values are reported with less significant figures in Table 3 (p.7) compared with Table 2 (p.7)? Please comment.
Lines 306-313: These lines are duplicates of previous without added value and should be omitted. Please comment.
- Methods
Line 350: Eq . (2) should be adapted to "CPI = [(TНexp − TНmeas) / THexp ]·100”. Please comment.
Appendix B
Lines 445-459: These lines should be merged with lines 316-335 to avoid duplicates. Please comment.
Appendix C
Lines 464-471: These lines should be merged with lines 159-178 to avoid duplicates. Please comment.
Appendix C
Lines 464-471: These lines should be merged with lines 159-178 to avoid duplicates. Please comment.
Appendix D
Lines 474-488: Comments and Table D.1 are duplicating Fig.2 and the comments formulated in lines 267-313 and should be omitted or merged. Please comment.
Author Response
Dear Reviewer,
Thank you very much for your thorough and detailed review. We greatly appreciate your clear and specific comments, which have made the process of revising the article much easier. Such specific and constructive feedback is especially valuable, as other reviewers often provide only general comments.
We have carefully reviewed all of your comments and incorporated them into the revised manuscript. The revisions are highlighted in green. Repetitive text has been removed or consolidated, table numbering and significant figures have been corrected, and duplication between the main text and the appendices has been reduced. We have retained the relevant data in the Zenodo worksheets, as they represent a complete and traceable dataset, including raw data and calculated values. In contrast, the tables in the manuscript contain summarized key results necessary for interpretation. Therefore, this obvious duplication has been retained to ensure full traceability and reproducibility of the data.
Thank you once again for your time and valuable comments, which have helped us significantly improve the manuscript.
1. Keywords. Іt is suggestion to include chloride as key word and "recirculation cooling water" and merge "recirculation cooling water" and" circular water management" into one keyword: "merge "recirculation cooling water management". Please comment. Response: Thank you for this helpful suggestion. We agree that chloride is an important parameter relevant to the characterization and management of recirculating cooling water and have therefore added “chloride” to the keywords. We also agree that the terms related to cooling-water recirculation and circular water management can be consolidated to avoid conceptual overlap. However, for grammatical and terminological accuracy, we have used “recirculating cooling water management” rather than “recirculation cooling water management.” Accordingly, the revised keywords are: “paper-based colorimetry; recirculating cooling water management; concentration factor; scaling tendency; total hardness; chloride; water reuse.”
2. Data description Lines 96-104: Sheet/worksheet 2 is identical to Table 1 (Lines 208-209). Please comment. Response: Thank you for your comment. We agree that the content of Worksheet 2 and Table 1 is similar, as both present comparative results of the proposed colorimetric tests and the corresponding reference measurements. However, their purposes differ. Table 1 provides a summary of the main validation results presented in the manuscript, whereas Worksheets 1 and 2 contain the complete dataset at the observation level, including individual experimental values. Worksheets 1 and 2 together allow the results to be traced. We have clarified what is additionally presented in Table 1.
3. Line 138: Dimensions of the discs? Please comment. Response: Thank you for your comment. We add “discs (10–12 mm in diameter)”.
4. Lines 144-145: Response of model chloride concentration of 0 mg/L Cl⁻ is missing in Fig. 1. Please comment. Response: Thank you for pointing this out. The 0 mg/L Cl⁻ level was included in the preparation of the Test A reference calibration scale, as specified in the Methods section (Lines 140–145), but it was not explicitly shown in Figure 1. We agree that this may cause ambiguity. We have therefore revised Figure 1 to explicitly include the 0 mg/L Cl⁻ reference field and clarified in the text that the zero-concentration solution was used as the blank/reference level of the calibration scale.
5. Line 145-147: What is the chloride concentration of the NaCl stock solution? Please comment. Response: Thank you for this comment. We agree that the concentration of the NaCl stock solution should be specified to ensure complete reproducibility of the calibration procedure. The revised Methods section now reports the concentration of the NaCl stock solution used for preparation of the calibration standards.
6. Lines 150-151: Response of model TH concentration of 0 mmol/L is missing in Fig. 1. Please comment. Response: Thank you for pointing this out. The 0 mmol/L TH level was included in the preparation of the Test B reference calibration scale, as specified in the Methods section (Lines 146–152), but the corresponding zero-level colour response was not explicitly represented in Figure 1. We have revised Figure 1 to include the 0 mmol/L TH reference field and clarified that this level represents the blank/reference point of the calibration scale.
7. Comment: Lines 153-154: What is the CaCO₃ concentration of the stock solution? Please comment. Response: Thank you for this important comment. We agree that the concentration of the CaCO₃ stock solution should be reported for complete reproducibility of the Test B calibration procedure. The revised Methods section now specifies the concentration of the CaCO₃ stock solution and clarifies that the required TH levels were prepared by appropriate dilution of the stock solution using deionized water.
8. Comment: Lines 157-158: Colorimetric values for 0 mg/L Cl⁻ and TH value of 0 mmol/L are missing in Fig. 1. Please comment. Response: We agree with the reviewer. The zero-concentration levels were included in the calibration design but were not sufficiently represented in Figure 1. We have therefore revised the figure to show the 0 mg/L Cl⁻ and 0 mmol/L TH reference fields explicitly.
9. Lines 180-185: Are duplicates of previous lines and should be omitted. Please comment. Response: We reviewed this section and removed the repetition from the previous procedure description, while retaining a separate subsection on validation and information on reference methods.
10.
Lines 180–185: Are duplicates of previous lines and should be omitted. Please comment. Response: Thank you for this comment. We carefully checked this section and removed the redundant statements describing the experimental procedure. The description of the reference-method validation in Section 2.3, including the comparison with ISO 9297:1989 and ISO 6059:1984, was retained because it introduces the independent reference methods and Table 1 and therefore provides information not duplicated by the preceding methodological description.
11. Lines 194–196: Number of significant figures of standard deviations and mean should be the same: e.g. "3.36 ± 0.34" instead of "3.36 ± 0.336". Please comment. Response: Thank you for pointing this out. The numerical presentation has been corrected throughout the manuscript so that the mean and standard deviation are reported with consistent numbers of significant figures. For example, “3.36 ± 0.336” has been corrected to “3.36 ± 0.34”.
12. Line 203: CF value of 1.0 is not found in Table 1. Please comment. Response: Thank you for this observation. CF = 1 represents the initial make-up water and was not calculated as a concentration-factor result because it corresponds to the reference starting condition rather than a concentration step. To avoid ambiguity, a note has been added to Table 1 indicating that CF = 1 represents the make-up-water baseline and was not calculated from a concentration experiment.
13. Lines 205–207: These lines are duplicates of lines 191–194 and lines 199–201 without added value and should be omitted. Please comment. Response: Thank you for this comment. The repeated statements summarizing the trends already presented in the preceding paragraphs were removed. The revised text retains only the information necessary to describe the validation results and their statistical interpretation.
14. Lines 208–209: Number of significant figures of standard deviations and mean should be the same in Table 1: E.g.: "70.40 ± 7.00" instead of "70.4 ± 7.00". Please comment. Response: Thank you for pointing this out. The numerical formatting in Table 1 has been revised so that the mean and standard deviation are reported consistently with the same number of decimal places. The example “70.4 ± 7.00” has therefore been corrected to “70.40 ± 7.00”.
15. Lines 210–213: These lines are duplicates of previous without added value and should be omitted. Please comment. Response: Thank you for this comment. The redundant statements were removed to avoid repetition and improve the conciseness.
16. Line 220: Numbering of Tables is not correct. Reference is made twice to Table 2 (p.6 and p.7) which is confusing when reading the discussions on p.6–7. Please comment. Response: Thank you for identifying this inconsistency. The duplicated table numbering and the corresponding cross-references were removed, and the table sequence and in-text references were revised to ensure consistent numbering throughout the manuscript.
17. In addition, Tables 2–4 are duplicates of sheet/worksheet 3–4 (Table 4b)–5 (Table 5b)–6. Please comment. Response: Thank you for this important comment. The tables presented in the manuscript provide a concise presentation of the principal results required for interpretation of the CPI, LSI, and RSI trends. The corresponding Excel worksheets were retained in the deposited dataset because they provide the underlying numerical records, replicate-level observations, and calculated variables required for data traceability and independent reproduction of the reported analyses. Thus, the manuscript tables and the dataset worksheets serve complementary purposes: the former facilitate interpretation of the main findings, whereas the latter preserve the complete data structure underlying those findings.
18. Line 239: "68.25%" instead of "68.5%" according to Table 2 on p.6. Please comment. Response:
Thank you for identifying this numerical inconsistency. The value has been corrected from “68.5%” to “68.25%” to correspond exactly to the value reported in Table 2.
19. Line 245: Numbering of Tables should be revised. Please comment. Response: Thank you for this comment. The table numbering and all corresponding in-text references have been checked and revised to ensure a consistent sequential order throughout the manuscript.
20. Line 254, Table 2: "CaI+" should be replaced by "Ca2+". Please comment. Response:
Thank you for identifying this typographical error. “CaI+” has been corrected to the chemically correct notation “Ca²⁺” throughout the table and manuscript.
21. Too many significant figures for Ca²⁺, TA, TDS and pHs. Please comment. Response: Thank you for this observation. The number of reported digits for Ca²⁺, TA, and TDS has been revised to reflect the appropriate precision of the corresponding measurements. The numerical presentation was standardized across the relevant tables and the deposited dataset. For pHₛ, we clarify that this parameter is not an experimentally measured pH value. It is the calculated saturation pH used in the calculation of the LSI. Therefore, the reported ±0.01 represents the estimated uncertainty associated with the calculation of pHₛ rather than an instrumental measurement uncertainty of an experimentally measured pH. The presentation of pHₛ has been revised accordingly.
22. Which experimental precautions have been taken to report pH values at the 0.001 level? Please comment. Response: Thank you for this important clarification. The experimentally measured pH values were not intended to imply an independently validated measurement precision of ±0.001 pH units. The values used for the scaling-index calculations have therefore been revised to an appropriate number of decimal places. In addition, pHₛ is explicitly identified as a calculated saturation-pH parameter rather than a directly measured quantity, and its reported uncertainty is associated with the calculation rather than with experimental pH measurement.
23. Line 265, Table 3: "CaI+" should be replaced by "Ca2+". Please comment. Response:
Thank you for identifying this typographical error. “CaI+” has been corrected to “Ca²⁺” in Table 3 and checked throughout the manuscript and dataset.
24. Too many significant figures for TA. Please comment. Response: Thank you for this observation. The number of reported digits for TA has been revised to reflect the appropriate analytical precision and has been made consistent with the corresponding values in the other tables and the dataset.
25. Why Ca²⁺, TA and pHs values are reported with less significant figures in Table 3 (p.7) compared with Table 2 (p.7)? Please comment. Response: Thank you for pointing out this inconsistency. The numerical formatting of Ca²⁺, TA, and pHₛ has been standardized across Tables 2 and 3 and the corresponding dataset. The revised presentation uses consistent precision for the same analytical parameters throughout the manuscript and deposited data.
26. Lines 306–313: These lines are duplicates of previous without added value and should be omitted. Please comment. Response: Thank you for this comment. The duplicated statements were removed because the information had already been presented in the preceding text and their repetition did not provide additional scientific information.
27. Line 350: Eq. (2) should be adapted to "CPI = [(THexp − THmeas) / THexp]·100". Please comment. Response: Thank you. Corrected as suggested.
28. Appendix B, Lines 445–459: These lines should be merged with lines 316–335 to avoid duplicates. Please comment. Response: Thank you. The duplicated text was removed; the information is retained in Lines 316–335.
29. Appendix C, Lines 464–471: These lines should be merged with lines 159–178 to avoid duplicates. Please comment. Response: Thank you. The duplicated text was removed; the information is retained in Lines 159–178.
30. Appendix C, Lines 464–471: These lines should be merged with lines 159–178 to avoid duplicates. Please comment. Response: Thank you. The duplicated text was removed; the information is retained in Lines 159–178.
31. Appendix D, Lines 474–488: Comments and Table D.1 are duplicating Fig. 2 and the comments formulated in lines 267–313 and should be omitted or merged. Please comment. Response: Thank you. The duplicated text and Table D.1 were removed; the relevant information is retained in Fig. 2 and Lines 267–313.
Round 2
Reviewer 2 Report
Comments and Suggestions for AuthorsAccept
Author Response
Dear Reviewer,
Thank you very much for your positive assessment and valuable comments. We greatly appreciate your constructive suggestions, which helped us further improve the manuscript. During the second revision round, the duplicated content identified in the manuscript was removed, and Figure 1 was revised and improved accordingly.
Thank you again for your careful review and for recommending acceptance of the manuscript.
Reviewer 3 Report
Comments and Suggestions for AuthorsDear Editor,
I have read the revised article "Experimental Dataset for Rapid Monitoring of Concentration and Scaling Tendency in Recirculating Cooling Water Using Paper-Based Colorimetric Tests”, including the responses to the reviewer.
Authors claim that duplicates have been removed. However, this is not correct: most of the recommendations and suggestions of the reviewer were ignored by the authors. Therefore, I refer again to my recommendations to avoid duplicates without any value, which were not considered by the authors. It is essential that the manuscript should be condensed and shortened considerably. To the contrary, the revised paper is even longer than the previous version.
If authors are willing to revise and condense the paper considerably, the manuscript can be reconsidered for publication. I do not recommend publication of this manuscript in its current form.
A list of comments and recommendations is addressed to the authors.
List of comments and recommendations
Line 208: Number of significant figures of standard deviations and mean should be the same: "1.05 ± 0.11 to 3.36 ± 0.34" instead of "1.05 ± 0.105 to 3.36 ± 0.336". Please comment.
Lines 210-212: Number of significant figures of standard deviations and mean should be the same in Table 1: "1.05 ± 0.11" instead of "1.05 ± 0.105" and "1.10 ± 0.11" instead of "1.10 ± 0.114". Please comment.
Lines 223-330: These lines are duplicates of previous lines 65-69 without added value and should be omitted. Please comment.
Authors claim that duplicates were removed but this was not the case. Please comment.
Lines 323-329: These lines are duplicates of previous lines without added value and should be omitted. Please comment.
Authors claim that duplicates were removed which was not the case. Please comment.
Appendix B
Lines 467-481: These lines should be omitted or merged with lines 331-388 (previous version) to avoid duplicates. Please comment.
Authors claim that duplicates were removed. However, lines 487-493 remain unaltered and were not removed and lines 331-388 (revised version) remained unchanged. Please comment.
Appendix B
Lines 467-481: These lines should be omitted or merged with lines 331-388 (previous version) to avoid duplicates. Please comment.
Authors claim that duplicates were removed. However, lines 487-493 remain unaltered and were not removed and lines 331-388 (revised version) remained unchanged. Please comment.
Appendix C
Lines 487-493: These lines should be merged with lines 159-178 (previous version) to avoid duplicates. Please comment.
Authors claim that duplicates were removed but this was not the case. However, lines 487-493 remain unaltered and were not removed and lines 165-184 (revised version) remained unchanged. Please comment.
Appendix D
Lines 474-488: Comments and Table D.1 are duplicating Fig.2 and the comments formulated in lines 267-313 and should be completely omitted. Authors claim that "The duplicated text and Table D.1 were removed; the relevant information is retained in Fig. 2 and Lines 267–313". However, Table D1 still is present in the manuscript and lines 285-329 remained unaltered. Please comment.
Lines 505, 512, 513, 516, 523, and 531: "colorimetric" instead of "colourimetric". Please comment.
Table E1: "colorimetric" instead of "colourimetric". Please comment.
Reference-method SD range": Not clear to me. Please comment.
Author Response
Dear Editor,
Thank you for your message and for the opportunity to further revise the manuscript. I would like to respectfully clarify several points concerning the reviewer’s comments. In the first round, some of the reviewer’s comments were themselves duplicated. In particular, comments referring to Lines 19 and 40, as well as Lines 29 and 30, were fully duplicated. In addition, some of the line numbers indicated by the reviewer did not correspond precisely to the passages requiring revision. Nevertheless, wherever the reviewer’s recommendations were applicable, I removed the indicated text or substantially shortened it.
I would also like to clarify the issue of repeated concluding statements. In my usual academic writing practice, I have traditionally used short concluding sentences at the end of subsections, such as “Therefore,” “Overall,” or similar formulations, to summarize the main point of the preceding subsection. These statements were intended as brief synthesis rather than as repetition of the preceding text. However, if the reviewer considers such concluding sentences to constitute unnecessary duplication, I am fully willing to remove them.
There are also some issues in the second-round comments that, in my view, would benefit from editorial clarification. For example, the comments concerning Appendix B are duplicated again, and there is confusion regarding the numbering of the lines to be removed. In particular, the text indicated as Lines 467–481, whereas the comment in the text refers to Lines 487–493.
Similarly, there is a comment concerning the rounding of the value ±0.105. I have revised this value according to the reviewer’s recommendation and rounded it to two decimal places. I would nevertheless appreciate the Editor’s consideration of this point, since the requested rounding convention may be interpreted differently depending on the adopted reporting and statistical convention.
Thank you very much for your consideration and for your assistance in resolving these points. I remain fully committed to improving the manuscript and ensuring that the final version is concise and suitable for publication.
Dear Reviewer,
Thank you very much for carefully reviewing the revised manuscript and for providing additional comments and recommendations. I appreciate your continued attention to the manuscript and am pleased that the majority of your suggestions have been addressed in the revision.
Regarding the issue of duplicated or unnecessary content, I would like to clarify that some of the comments in the second round were themselves duplicated. Specifically, the comments referring to Lines 19 and 40, as well as Lines 29 and 30, were repeated. In addition, some of the line numbers indicated in the comments did not correspond precisely to the passages concerned. Nevertheless, wherever the recommendation was applicable, I removed the indicated material or substantially shortened it. In most cases, the relevant passages have been partially condensed. I would also like to explain the presence of some short concluding statements at the end of subsections. In my usual academic writing practice, I have used expressions such as “Therefore,” “Overall,” and similar formulations to briefly summarize the main point of a subsection. These sentences were intended to provide synthesis rather than to reproduce information already presented. However, I understand your concern that such statements may be perceived as repetitive. Therefore, following your recommendation, I am prepared to remove these concluding sentences wherever they do not provide additional information.
I have also addressed the recommendation concerning the numerical value ±0.105 and revised its presentation by rounding it to two decimal places, i.e., ±0.11, in accordance with your comment.
Finally, I would like to clarify the comment concerning the spelling of “colorimetric” / “colourimetric” in Appendix E of the previous version (now Appendix D). These are the American and British English variants of the same term, respectively. The manuscript, including its title, consistently uses the American English spelling “colorimetric.” Therefore, I have retained “colorimetric” in the appendix as well, in order to maintain consistency throughout the manuscript rather than introducing a different spelling in a single section.
I sincerely appreciate your comments and recommendations. They have helped me further condense and improve the manuscript. I have carefully considered the remaining suggestions and have implemented the revisions wherever they were applicable and scientifically justified.
Line 208: Number of significant figures of standard deviations and mean should be the same: "1.05 ± 0.11 to 3.36 ± 0.34" instead of "1.05 ± 0.105 to 3.36 ± 0.336". Please comment. Response: Addressed. The values have been corrected accordingly.
Lines 210–212: Number of significant figures of standard deviations and mean should be the same in Table 1: "1.05 ± 0.11" instead of "1.05 ± 0.105" and "1.10 ± 0.11" instead of "1.10 ± 0.114". Please comment. Response: Addressed. The values in Table 1 have been corrected accordingly.
Lines 223–330: These lines are duplicates of previous lines 65–69 without added value and should be omitted. Please comment. Response: Addressed. The duplicated text has been removed.
Lines 323–329: These lines are duplicates of previous lines without added value and should be omitted. Please comment. Response: Addressed. The duplicated text has been removed.
Appendix B Lines 467–481: These lines should be omitted or merged with lines 331–388 (previous version) to avoid duplicates. Please comment.
Response: Addressed. The duplicated text has been removed.
Appendix B: Authors claim that duplicates were removed. However, lines 487–493 remain unaltered and were not removed and lines 331–388 (revised version) remained unchanged. Please comment. Response: Addressed. The duplicated text has been removed.
Appendix B Lines 467–481: These lines should be omitted or merged with lines 331–388 (previous version) to avoid duplicates. Please comment. Response: Addressed. The text was rechecked and removed))
Appendix B: Authors claim that duplicates were removed. However, lines 487–493 remain unaltered and were not removed and lines 331–388 (revised version) remained unchanged. Please comment. Response: Addressed. The text was rechecked and removed))
Appendix C Lines 487–493: These lines should be merged with lines 159–178 (previous version) to avoid duplicates. Please comment. Response: Addressed. The duplicated text has been removed.
Appendix C: Authors claim that duplicates were removed but this was not the case. However, lines 487–493 remain unaltered and were not removed and lines 165–184 (revised version) remained unchanged. Please comment.
Response: Addressed. The duplicated text has been removed.
Appendix D Lines 474–488: Comments and Table D.1 are duplicating Fig. 2 and the comments formulated in lines 267–313 and should be completely omitted. Please comment. Response: Addressed. The entire Appendix D, including Table D.1, has been removed.
Lines 505, 512, 513, 516, 523, and 531: "colorimetric" instead of "colourimetric". Please comment. Response: Addressed. “Colorimetric” has been retained consistently.
Table E1: "colorimetric" instead of "colourimetric". Please comment. Response: Addressed. “Colorimetric” has been retained for consistency.
“Reference-method SD range”: Not clear to me. Please comment.
Response: Clarified. The term has been defined (note new Table D1).
Round 3
Reviewer 3 Report
Comments and Suggestions for AuthorsDear Authors,
I have read the revised article "Experimental Dataset for Rapid Monitoring of Concentration and Scaling Tendency in Recirculating Cooling Water Using Paper-Based Colorimetric Tests”, including the responses to the reviewer. Authors have implemented the proposed comments of the reviewer.
Minor comment
There is still inconsistency in the spelling colorimetric/colourimetric in lines 455, 462, 463, 466, 473, 481 and in Table D1. Throughout the manuscript and in the title "colorimetric" is used. For spelling consistency, it is recommended to use "colorimetric" instead of "colourimetric".
Author Response
Dear Reviewer,
Thank you very much for your careful reading of the revised manuscript and for your positive assessment of the revisions.
We have corrected the inconsistency in the spelling of “colourimetric” and replaced it with “colorimetric” in Lines 455, 462, 463, 466, 473, and 481, as well as in Table D1. The spelling “colorimetric” is now used consistently throughout the manuscript and in the title.