24 November 2026

25 Pages

Photographic Tooth Color Agreement with a Reference Spectrophotometer Using DSLR and Three Smartphones in Laboratory and Clinical Evaluations with Exploratory AI Correction and Uncertainty Analysis

,
and
1
Department of Prosthetic Dental Sciences, College of Dentistry, Qassim University, Buraidah 51452, Qassim, Saudi Arabia
2
Department of Digital Learning, Sulaiman AlRajhi University, AlBukayriyah 51941, Qassim, Saudi Arabia
3
School of Computing, University of Eastern Finland, Yliopistokatu 2, 80100 Joensuu, Finland
*
Author to whom correspondence should be addressed.

Abstract

Background/Objectives: To evaluate the color agreement of a digital single-lens reflex (DSLR) camera and three smartphone systems (iPhone 17 Pro Max, Google Pixel 10 Pro, Samsung Galaxy S26 Ultra) against a reference spectrophotometer for tooth shade matching, and to conduct an exploratory analysis of AI-based color correction and uncertainty flagging. Methods: The study comprised a laboratory phase using 29 VITA 3D-Master shade tabs and a clinical phase involving maxillary central incisors of 100 participants. Images were captured under standardized LED illumination and calibrated using a neutral gray reference. Euclidean color differences (ΔEab*) were calculated against a VITA Easyshade Advance V reference. An in silico study applied nested, participant-level cross-validation to evaluate Random Forest and Convolutional Neural Network (CNN) models for color correction, alongside uncertainty flags for identifying unreliable predictions. Results: The DSLR showed the lowest median ΔEab* in the laboratory (0.52) and clinical (0.68) phases. Clinically, 100% of Pixel, 99% of iPhone and 83% of Samsung measurements were within the selected ΔEab* ≤ 2.7 benchmark. Random Forest correction did not significantly reduce median error relative to calibrated photographs. The exploratory CNN introduced large smartphone errors, reaching ΔEab* = 7.89. Uncertainty flags detected 11/13 iPhone errors above 2.7 (84.6%; exact 95% CI 54.6–98.1%) and 18/23 Samsung errors (78.3%; 56.3–92.5%), while withholding 22% and 24% of predictions and leaving two and five errors undetected. Flagging did not establish added value over the calibrated photographic baseline. Conclusions: Under the tested conditions, the gray-card-calibrated DSLR workflow most closely agreed with the reference spectrophotometer. Smartphone performance varied by device and acquisition workflow. Random Forest correction provided no demonstrated added benefit, whereas the exploratory CNN introduced large errors in some smartphone predictions. Independent external validation is needed before AI-based correction or uncertainty flags can support clinical decisions.

1. Introduction

Digital photography supports dental documentation and communication [1,2]. Smartphone images have been investigated for remote caries assessment [3], monitoring during orthodontic treatment [4], computer-assisted caries detection [5], and evaluation of prosthetic fit [6].
Accurate tooth shade matching remains challenging in restorative dentistry [7,8]. Visual matching with commercial shade guides is influenced by observer fatigue, lighting conditions, and metamerism, which can reduce agreement within and between observers [8,9,10].
Instrumental systems provide an objective approach to color measurement [9,11]. Contact spectrophotometers measure reflected light and provide International Commission on Illumination (CIELAB) coordinates (L*, a*, and b*) under standardized internal illumination [10,11]. Standardized digital photography, including protocols using polarization and a neutral gray reference, offers another approach to shade assessment [7,12]. Its performance depends on lighting and calibration [12]. DSLR workflows require suitable camera and control of the acquisition settings [13,14].
Smartphone cameras offer a convenient option for dental photography [13,15]. Dental applications have been investigated for shade classification and reproduction [16,17], but performance depends on the device and workflow [18]. Studies of perceived image quality and user preferences address different outcomes from instrumental color agreement [19,20]. RAW file capture also does not necessarily exclude computational processing; Apple ProRAW, for example, combines RAW information with iPhone image processing [21]. Device-specific color accuracy therefore requires direct validation.
Shade guides provide standardized specimens for laboratory comparison, although color correspondence between guide systems is not exact [22]. Camera type and acquisition conditions can influence photographic color assessment [14,23,24]. Performance can be expressed as color difference (ΔE) values relative to a reference instrument.
ΔEab* describes Euclidean separation of CIELAB coordinates. The selected ΔEab* ≤ 2.7 acceptability benchmark is distinct from the ΔEab* ≤ 1.2 perceptibility benchmark [25]; neither establishes instrument interchangeability. CIEDE2000 provides an additional perceptually weighted assessment.
Laboratory findings require clinical validation because shade tabs and natural teeth are different measurement targets. Clinical studies have compared photographic and spectrophotometric tooth color measurements [12,26]. Differences between laboratory and clinical results may reflect specimen characteristics or acquisition conditions; a comparison between phases alone cannot identify their individual effects.
Machine learning offers a possible way to estimate reference color from photographic measurements. Kim et al. developed a shade-matching device using a support vector machine [27], while Menini et al. compared visual and technology-based color matching [28]. These studies support further investigation of computational shade assessment, but they do not, by themselves, establish that a complex model outperforms a simple calibration. Predictive models used for correction should also indicate when their estimates are unreliable, for example through uncertainty estimation [29,30]. Any secondary AI analysis of an existing dataset must distinguish performance on training observations from out-of-fold performance in internal validation, and both from performance in genuinely external patients and clinics.
Gray-card normalization constrains neutral color balance and exposure but may leave device-dependent residual differences in tooth colors. Machine learning was therefore evaluated as an exploratory residual correction, with calibrated photographs and simple correction methods as comparators. Improvement was assessed empirically rather than assumed.
Previous studies have investigated photographic tooth color assessment under different lighting and calibration protocols. However, agreement obtained on shade tabs does not necessarily predict agreement on natural teeth, and the incremental benefit of machine learning after gray-card normalization remains uncertain. This study therefore compares photographic workflows with a reference spectrophotometer in laboratory and clinical settings. A secondary exploratory analysis examines whether AI correction improves on calibrated photographs and simple correction baselines, and whether uncertainty estimates identify unreliable model predictions.
The primary aim was to compare CIELAB color agreement of four photographic systems with the VITA Easyshade Advance V, first using 29 VITA 3D-Master shade tabs, and then clinically using maxillary central incisors from 100 participants.
The secondary AI analysis explored whether correction could improve reference agreement beyond gray-card normalization and simple calibration baselines, and whether model uncertainty could identify unreliable predictions. This component was exploratory and was not designed to provide confirmatory evidence of clinical benefit. The primary laboratory and clinical comparisons addressed the null hypotheses that CIELAB coordinates do not differ among the five measurement modalities and that ΔEab* does not differ among the four photographic workflows.

2. Materials and Methods

This research included 3 studies, a laboratory comparison of shade tabs evaluated the iPhone 17 Pro Max, Samsung Galaxy S26 Ultra, and Google Pixel 10 Pro alongside a Canon DSLR, using contact spectrophotometry as the reference. A clinical study of the maxillary central incisors of 100 participants using the same devices, and an in silico study using artificial intelligence to analyze the results of the clinical study. The research protocol was conducted in strict adherence to the Declaration of Helsinki and approved by the Institutional Review Board and Ethics Committee of the College of Dentistry, Qassim University (IRB: QUDENT25-02-26) on 25 February 2026. Written informed consent was obtained from all participating human subjects prior to clinical procedures.

2.1. Laboratory Study

The laboratory sample set consisted of all 29 shade tabs of the VITA Toothguide 3D-Master system (VITA Zahnfabrik, Bad Säckingen, Germany), including the 26 standard chromatic tabs and the 3 dedicated bleached shade guide tabs (0M1, 0M2, 0M3). To eliminate uncontrolled ambient lighting and spurious chromatic reflections, all photographic acquisitions were conducted inside a custom light-tight isolation box lined with non-reflective matte black paint.
Standardized illumination was delivered using a specialized mobile dental LED bracket system (NICEDEN, Shenzhen, China) delivering a power output of 20 W, a color temperature calibrated to D55 standard daylight (5500 K), and an ultra-high color rendering index (CRI ≥ 95). The bracket incorporated three illumination zones: central, lateral right, and lateral left. Only the lateral bilateral LED banks were activated on their primary intensity setting and fitted with neutral translucent white polymer diffusers to generate diffuse illumination across the target field (Figure 1 and Figure 2).
Figure 1. The LED flashlight with 3 groups of light spots: central, right, and left spots.
Figure 2. The light white diffusers covering the right and left light spots.
All shade tabs were oriented identically and supported horizontally against a neutral white-balance reference gray card (WhiBal G7, Michael Tapes Design, Melbourne, FL, USA; nominal values: L* = 75, a* = 0, b* = 0). Camera positioning relative to the shade tab was standardized using an optical bench rail mount (Figure 3).
Figure 3. The white balance reference gray card, and a group of dental shade tabs.
  • Instrumental and Photographic Device Configurations
Five diagnostic modalities were evaluated:
  • Contact Spectrophotometer (Reference Standard)
A clinical contact spectrophotometer (VITA Easyshade Advance V; VITA Zahnfabrik, Bad Säckingen, Germany) was calibrated prior to each measurement cycle using its integrated white calibration ceramic block, in accordance with manufacturer instructions and established reliability protocols [10,26]. The device’s 45/0 measurement geometry probe tip was positioned perpendicular to and in flush contact with the center of the middle third of each shade tab (Figure 4). Three successive readings were obtained per tab in single-tooth measurement mode, and the digital L*, a*, and b* values were averaged.
Figure 4. Spectrophotometric color determination of a VITA 3D-Master shade tab using the VITA Easyshade Advance V probe positioned perpendicularly against the middle third of the tab surface.
2.
DSLR Camera System
A digital single-lens reflex camera body (Canon EOS 750D; Canon Inc., Tokyo, Japan) equipped with a 1:1 macro lens (Canon EF 100mm f/2.8 Macro USM) was mounted to the optical bench. Camera settings were configured fully manually: ISO 2500, 100 mm, f/5.6, 1/160 s, Adobe RGB color space, and RAW (CR2) file capture. Illumination was supplied by the NICEDEN LED system (Figure 5).
Figure 5. The setup of the DSLR camera, flashlight, tooth tabs, and white-gray balance card.
3.
iPhone 17 Pro Max
An iPhone 17 Pro Max (Apple Inc., Cupertino, CA, USA) was mounted in the NICEDEN housing. Images were acquired in Apple ProRAW Max (.DNG) mode. Autofocus and autoexposure were locked on the middle third of the tab, and exposure compensation was set to −1.0 EV (Figure 6) [21].
Figure 6. The setup of the smartphone, flashlight, tooth tabs, and white-gray balance card.
4.
Samsung Galaxy S26 Ultra
A Samsung Galaxy S26 Ultra (Samsung Electronics, Suwon, Republic of Korea) was mounted in the same rig. Images were acquired in Expert RAW mode and saved as DNG files. The acquisition settings were ISO 50, shutter speed 1/125 s, focus on the middle third of the tab, and white balance set to 5500 K.
5.
Google Pixel 10 Pro
A Google Pixel 10 Pro (Google LLC, Mountain View, CA, USA) was mounted in the same rig. Images were saved as RAW DNG files using Pro Controls. The acquisition settings were ISO 50, shutter speed 1/125 s, focus on the middle third of the tab, and white balance set to 5500 K.
Device-specific acquisition settings were used; therefore, the comparison estimates agreement for the complete tested photographic workflows. Camera hardware, exposure choices, optics and device processing were not varied independently, and the observed differences cannot be attributed exclusively to the camera body or sensor.
The acquisition protocol specified three consecutive photographs of each of the 29 shade tabs with each of the four photographic devices, corresponding to 348 planned images (29 × 4 × 3).

2.2. Clinical Study

Patient Selection and Clinical Standardization

One hundred healthy adult human participants (44 males, 56 females, aged 20–74, mean 49.1) were recruited from the patient clinics of the College of Dentistry, Qassim University. The inclusion criteria required fully erupted, structurally intact maxillary central incisors free from caries, restorations, endodontic therapy, developmental enamel defects (fluorosis, amelogenesis imperfecta), extrinsic staining, or history of orthodontic appliances [26].
Clinical preparation included the following steps:
Hydration protocol: Teeth were cleaned with fluoride-free pumice using a low-speed handpiece, rinsed, and kept moist with saliva or distilled water. Under the study protocol, photographic and spectrophotometric recordings were completed within 60 s of surface blotting.
Soft tissue and background isolation: A matte black silicone contrastor was positioned palatal to the maxillary anterior teeth to provide a consistent background.
Reference Placement: A miniaturized WhiBal reference gray card was fixed adjacent to the incisal edge of the target central incisor using a custom silicone index, remaining within the identical focal plane and depth of field (Figure 7).
Figure 7. Clinical tooth shade measurement of the maxillary right central incisor using the VITA Easyshade Advance V contact probe positioned on the middle third.
  • Clinical Data Acquisition
Spectrophotometric Acquisition: The VITA Easyshade Advance V probe, sheathed in an infection-control barrier, was placed perpendicularly against the middle third of the labial surface of the maxillary right central incisor [10,26]. Three successive readings were recorded and averaged per patient (Figure 7).
Photographic Acquisitions: The DSLR camera and three smartphone platforms (iPhone 17 Pro Max, Samsung Galaxy S26 Ultra, Google Pixel 10 Pro) were successively mounted to a clinical positioning arm in the standardized acquisition position. The NICEDEN lighting system was used for photographic acquisition. Three replicate RAW images were obtained per modality per participant (Figure 8).
Figure 8. Clinical photographic setup showing the patient with lip retractor, black intraoral contrastor, and the miniaturized WhiBal gray reference card adjacent to the tooth, and the camera positioned in front of the maxillary central incisor.

2.3. Image Processing and Color Standardization

All raw digital images (CR2 and DNG formats) were imported into Adobe Photoshop 2026 (v27.x) and developed within Camera Raw 18.2.2 (Adobe Systems Inc., San Jose, CA, USA). Standardized color normalization followed an established two-step calibration protocol (Figure 9, Figure 10 and Figure 11) [7]:
Figure 9. White balance correction in Adobe Photoshop 2026 (Camera Raw 18.2.2). The White Balance Selector tool (eyedropper) was positioned over the WhiBal gray card reference area to neutralize the color of all images prior to color analysis.
Figure 10. Exposure standardization in Camera Raw 18.2.2 using the Exposure slider adjusted to target a luminance value of L = 75.
Figure 11. Standardized image of the shade guide tab after cropping, with the tab occupying the full image frame prior to automated color extraction.
Chromatic Neutralization: The Camera Raw White Balance Selector tool (eyedropper) was positioned over the neutral gray card reference area adjacent to the target to eliminate color cast and establish an objective white point.
Luminance Normalization: The Exposure slider under the Light panel was adjusted iteratively until the histogram readout over the WhiBal gray target converged exactly on L* = 75.0, a* = 0.0, and b* = 0.0.
The values L* = 75, a* = 0 and b* = 0 were the selected normalization targets, rather than independently measu`red values of the card in this study. Gray-card normalization does not establish identical camera processing pipelines.
Standardized images were cropped to circumscribe the anatomical crown or shade tab boundary and organized systematically into indexed directories.

2.4. Digital Color Extraction via R Statistical Environment

Color coordinates were extracted with an R script (v4.4.x; R Foundation for Statistical Computing, Vienna, Austria) utilizing the magick, colorspace, and dplyr packages.
For each processed image, the coordinate centroid of the middle third of the tooth or shade tab was identified algorithmically. An 11 × 11 pixel sampling window (totaling 121 pixels) was centered on this point to eliminate single-pixel noise and avoid edge artifacts. The 16-bit linear sRGB/Display-P3 values across the 121 pixels were converted to CIE L*a*b* coordinates relative to the standard D65 illuminant. The mean L*, a*, and b* values across the three replicate images per specimen were computed.

2.5. Color Difference Formulation

Color difference between the reference spectrophotometer (Easyshade Advance V) and each photographic imaging modality (DSLR, iPhone 17 Pro Max, Samsung Galaxy S26 Ultra, Google Pixel 10 Pro) was calculated using the Euclidean CIE L*a*b* ( Δ E ab * ) formula:
Δ E ab * = L 1 * − L 2 * 2 + a 1 * − a 2 * 2 + b 1 * − b 2 * 2
where L 1 * , a 1 * , b 1 * denote the coordinates obtained by the reference spectrophotometer, and L 2 * , a 2 * , b 2 * denote the corresponding coordinates recorded by the respective photographic system.
CIELAB color difference (ΔEab*) was retained as the principal metric used in the original analysis because it directly describes Euclidean differences in the reported coordinates. CIEDE2000 (ΔE00) adjusts for nonuniform perceptual sensitivity and is the proposed key secondary sensitivity analysis. Formula-specific perceptibility and acceptability benchmarks are 1.2 and 2.7 for ΔEab*, and 0.8 and 1.8 for ΔE00, respectively [25]. The existing manuscript reports descriptive ΔE00 results in Supplementary Table S9.
The 50:50 perceptibility threshold denotes a color difference detected by approximately half of observers; the 50:50 acceptability threshold denotes a difference judged acceptable by approximately half of observers [25].
The published 50:50 perceptibility and acceptability thresholds were used as contextual benchmarks rather than definitive clinical decision rules. We report the proportions below each benchmark and distinguish these from individual method agreement and clinical outcomes.
Values above ΔEab* = 2.7 were described as exceeding the selected acceptability benchmark. Values at or below this benchmark do not prove instrument interchangeability, successful shade selection or an acceptable final restoration.

2.6. Visual Subjective Evaluation

Eight board-certified prosthodontists from the Department of Prosthetic Dental Sciences, College of Dentistry, Qassim University, served as independent visual evaluators. Evaluators were presented with the actual physical specimen (shade tab or patient) alongside high-definition, color-calibrated monitors displaying the corresponding standardized photographic images from the four imaging modalities in a randomized, blinded sequence. Evaluators graded color reproduction accuracy on a 5-point Likert scale (1 = completely unacceptable mismatch; 5 = perfect shade match, with a score of 3 or more as “acceptable”). Visual fatigue was controlled by enforcing a 2 min washout period between consecutive image pairs.

2.7. Statistical Analysis of the Laboratory and Clinical Studies

Sample size, randomization, and general parameters. The laboratory sample comprised the complete VITA 3D-Master set of 29 shade tabs. The clinical sample of 100 participants was a feasibility-based convenience sample. No formal sample-size calculation was performed. Precision was assessed using confidence intervals rather than observed post hoc power. With 100 observations, an exact binomial 95% interval near a proportion of 0.50 has a half-width of approximately 10.2 percentage points; with 29 observations, the corresponding maximum half-width is approximately 19.0 percentage points. The clinical convenience sample and the fixed laboratory shade set limit generalization beyond the observed study conditions. To limit order effects such as tooth dehydration within the 60 s measurement window, the order of the five measurement modalities (four cameras and the spectrophotometer) was randomized for each participant using computer-generated permutation.
All tests were two-sided with α = 0.05. Holm correction was applied within each of the following families, separately for each phase: (i) the twelve device-versus-reference contrasts (four devices × three coordinates); (ii) the twelve corresponding equivalence tests; (iii) the six pairwise Wilcoxon comparisons among devices; and (iv) the six pairwise McNemar comparisons of acceptability. Analyses were performed in R (v4.4.x; R Foundation for Statistical Computing, Vienna, Austria).
Reliability and precision. Reliability of the three successive readings was assessed for each device and coordinate with a two-way mixed-effects, absolute-agreement, single-measurement intraclass correlation coefficient (ICC) and 95% bootstrap confidence intervals [31]. Because the narrow color range of healthy incisors can deflate ICC values, precision was also quantified with the within-subject standard deviation (Sw), the repeatability coefficient (2.77 × Sw), and the ΔEab* between replicates. All comparative analyses used ΔEab* computed from replicate means, which reduces image noise; a sensitivity analysis using single images was performed to reflect single-shot clinical use.
Hypothesis 1 (Color coordinates).
For each phase and each coordinate (L*, a*, b*), differences among the five modalities were tested with the Friedman test. Mean camera–Easyshade differences were estimated with paired t tests and 95% confidence intervals, with Holm adjustment across twelve camera–coordinate contrasts. Two one-sided tests (TOST) [32] assessed small mean bias using study-specific margins of ±1.2 units per coordinate. The criterion was met when the 90% confidence interval of the mean difference lay within these margins. These coordinate-wise margins are not independently validated clinical equivalence boundaries: simultaneous differences of 1.2 in all three coordinates correspond to ΔEab* = √3 × 1.2 ≈ 2.08, rather than 1.2.
Hypothesis 2 (Color differences).
Because ΔEab* is non-negative and right-skewed, differences among the four photographic systems were tested with the Friedman test in each phase, with Kendall’s W as the effect size. The Friedman test used complete cases, and the number of excluded specimens is reported. Pairwise comparisons between device pairs (six per phase) used the Wilcoxon signed-rank test with Holm adjustment. The Shapiro–Wilk test on paired differences was reported descriptively and did not determine the choice of test (Supplementary Table S12).
Perceptual benchmark proportions. The selected benchmarks were analyzed with proportions rather than by testing means against a threshold. For each device and phase, the proportions of specimens with ΔEab* ≤ 1.2 and ≤ 2.7 are reported with exact Clopper–Pearson 95% confidence intervals, together with the median, 95th percentile and maximum ΔEab*. Proportions at ≤2.7 were compared among devices with Cochran’s Q test, followed by pairwise McNemar tests with Holm adjustment.
Method agreement. Bland–Altman analysis was performed separately for L*, a* and b* for each device and phase [33], using replicate-mean coordinates. Mean bias and 95% limits of agreement were reported with 95% confidence intervals. Proportional bias was examined by regressing differences on pair means and reporting the slope with its 95% confidence interval. The ±1.5-unit bands were study-specific descriptive reference bands, not validated clinical equivalence limits. Simultaneous differences of 1.5 in all three coordinates correspond to ΔEab* ≈ 2.60; separate 95% coordinate limits do not form a joint 95% limit on three-dimensional color difference.
The coordinate-wise TOST margins and Bland–Altman reference bands address different estimands and are not validated clinical equivalence limits. Small mean bias does not establish close agreement for an individual specimen. Individual agreement is therefore interpreted using the limits of agreement together with the specimen-level color-difference distribution.
Measurement uncertainty framework. The following propagation framework describes how photographic and reference uncertainty contribute to the observed difference; it is not a numerical uncertainty budget. For each specimen, let C ¯ and R ¯ be the mean photographic and reference CIELAB vectors, and let d = C ¯ − R ¯ . The observed color difference is E = ||d||. If U_C and U_R are the covariance matrices of the mean measurements and U_CR is their cross-covariance, the covariance of d is U_d = U_C + U_R − U_CR − U_CRᵀ. For E > 0, first-order propagation gives u2(E) ≈ gᵀU_dg, where g = d/E. For independent triplicate acquisitions, the repeatability contribution to each mean covariance is the single-acquisition covariance divided by three. Shared calibration and other systematic components do not decrease by this factor. Near zero color difference, simulation-based propagation is preferable to this linear approximation [34,35].
A numerical uncertainty budget requires replicate CIELAB coordinates and calibration records. The median repeat-measurement ΔEab* values alone are not standard uncertainties and cannot be subtracted from camera–reference color differences.
Visual evaluation. Mean Likert scores and the proportion of ratings of 3 or more were calculated for each device. Inter-rater reliability was quantified with Krippendorff’s α (ordinal) within each device. Differences among devices in specimen-average scores were tested with the Friedman test, followed by Holm-adjusted Wilcoxon signed-rank tests. The relationship between visual scores and instrumental ΔEab* was assessed separately for each device with Spearman’s rank correlation between the per-specimen median score and ΔEab*, with specimen-level bootstrap 95% confidence intervals (2000 resamples, keeping the eight ratings of each specimen together).

2.8. In Silico Study: Artificial Intelligence Analysis of Device Performance

Aim, reporting framework and provenance. This exploratory secondary analysis of the clinical dataset evaluated whether machine learning could predict the reference spectrophotometer L*, a*, b* values from photographic data and flag unreliable predictions. Reporting followed TRIPOD+AI [29]. Development and validation on the same dataset by resampling constitutes internal validation (TRIPOD type 1b). Cross-validation reduces but does not remove optimism, and no claim of external validation is made.
The models were developed by the study authors, who also collected the data. No independent verification of the modeling was performed.
Validation design. Models were validated with nested, participant-level cross-validation: a single outer 5-fold partition (20 participants and 80 device observations per fold) and an inner 4-fold loop within the training participants of each outer fold. All rows, replicate images and augmented copies belonging to a participant stayed in the same fold. Fold assignments were identical for all models so that comparisons were paired. Preprocessing (e.g., scaling) was fitted on training data only. Hyperparameter selection, training duration and calibration of the uncertainty threshold used inner-loop data only. Each participant’s out-of-fold prediction was averaged across three random seeds (42, 101 and 202).
Inputs, targets and baselines. Tabular models used the replicate-mean photographic CIELAB coordinates. The CNN used image pixels. Models were pooled across the four devices with a categorical device indicator. Predictors excluded any reference-derived information. The target was the correction (reference minus camera coordinates), and the corrected estimate was the photographic value plus the predicted correction. The following comparators were evaluated: (1) the gray-card-calibrated photographic values before AI correction; (2) a constant predictor of the training-set mean of the reference L*, a*, b*, which tests whether models merely exploit the narrow color clustering of healthy incisors; (3) a per-device mean-offset correction (the calibrated photographic value plus the mean training-set correction for that device); and (4) a multi-output ridge regression with device indicators and device-by-coordinate interactions, with the penalty chosen by inner cross-validation.
Random Forest (main exploratory model). A multi-output Random Forest regressor with 500 trees was implemented in Python (scikit-learn 1.5.2). Maximum depth (3, 5, 8, unrestricted), minimum samples per leaf (1, 3, 5, 10) and number of features per split (1, 2, 3) were tuned by inner cross-validation.
Convolutional neural network (exploratory). A ResNet-34 pretrained on ImageNet was implemented in PyTorch 2.5.0. Its final layer was replaced by a dropout layer (p = 0.3) and a 3-node linear regression head; the device indicator was concatenated to the pooled features before this head. Inputs were 224 × 224-pixel crops of the middle third of the tooth, excluding the gray card. Targets were standardized with training-set statistics. Training used the Adam optimizer (learning rate 0.001) and mean squared error loss, with early stopping on validation participants held out from the training folds. The three replicate images of a participant were used as separate training samples, and their predictions were averaged at evaluation. Augmentation (rotations up to ±10° and scaling of 0.9–1.1) was applied to training images only, on a larger crop that was then center-cropped so that no padded pixels entered the image. No brightness, contrast or hue augmentation was used, because these change the regression target, and no augmentation was applied at test time. Because 100 participants cannot support definitive inference on a highly parameterized network, all CNN results are descriptive and exploratory.
Uncertainty flagging. For the Random Forest, uncertainty was estimated with a quantile regression forest (quantile-forest 1.3.0) as the width of the 10th–90th percentile interval of the predicted correction for each coordinate. For the CNN, Monte Carlo dropout [30] used 50 stochastic forward passes with batch-normalization layers in evaluation mode, with the same interval width taken from the empirical distribution of predictions. The three coordinate widths were combined into one score as their Euclidean norm. Flag thresholds were set for the CNN only; for the Random Forest, only the discrimination of the score was evaluated. For each outer fold, the CNN threshold was calibrated on out-of-fold predictions from the inner loop, never on training predictions or test data. It was set at the 20th percentile of the inner-loop uncertainty scores of predictions with errors above ΔEab* = 2.7, which gives an inner-loop sensitivity of at least 80% with the smallest flagged fraction; Youden’s index was used instead if fewer than 10 such errors existed in the inner-loop data. The added value of the scores was compared with a trivial baseline, the Mahalanobis distance of a participant’s calibrated photographic coordinates from the training-set mean. Evaluation on the outer test folds reported the number of errors above 2.7, the AUROC for detecting them (participant-level bootstrap 95% confidence intervals; descriptive if fewer than 10 events), the risk–coverage curve (Supplementary Figure S5), the proportion flagged, sensitivity and specificity at the fixed threshold, and the proportion of predictions with ΔEab* ≤ 2.7 among unflagged versus all cases.
Outcomes. The principal outcome within this exploratory analysis was ΔEab* between the corrected estimate and the reference, computed per participant and device from out-of-fold predictions. Secondary outcomes were MAE, RMSE and bias per channel, ΔE00, the proportions with ΔEab* ≤ 1.2 and ≤ 2.7, and calibration (slope and intercept of the reference values regressed on the corrected values, per channel).
Statistical comparisons. All comparisons were paired on the same participants and performed separately for each device. The exploratory paired comparisons were Random Forest versus calibrated photographic values and Random Forest versus ridge. Multiplicity-adjusted p values do not make this secondary analysis confirmatory. Median ΔEab* was compared with the Wilcoxon signed-rank test (family of eight tests, Holm-adjusted), and the proportion with ΔEab* ≤ 2.7 with McNemar’s test (a second Holm family of eight tests). For each contrast, the difference in median ΔEab* is reported with a participant-level cluster bootstrap 95% confidence interval (2000 resamples). Other comparisons (Random Forest versus the constant and mean-offset baselines, and all CNN comparisons) were secondary and are reported with confidence intervals and without hypothesis tests. Because training sets overlap across folds, cross-validated confidence intervals are approximate and may understate uncertainty.
Exploratory performance criteria. For each device, the Random Forest correction was considered successful if, relative to the calibrated photographic values: (a) the reduction in median ΔEab* was statistically significant after Holm adjustment; (b) the median reduction was at least 0.6 (half the perceptibility threshold); and (c) the proportion with ΔEab* ≤ 2.7 rose by at least 10 percentage points with a Holm-adjusted significant McNemar test. If 90% or more of the calibrated photographic measurements for a device were already at or below 2.7, so that criterion (c) could not be met, the ΔEab* ≤ 1.2 proportion was used instead. Added value over simple calibration was concluded for a device only if the Random Forest also achieved a Holm-adjusted significant reduction in median ΔEab* relative to the ridge model.

3. Results

3.1. Laboratory Study

All 29 shade tabs were measured three times with each of the five modalities, and none was excluded. Color differences from the Easyshade were calculated from replicate-mean coordinates (Table 1).
Table 1. Laboratory color differences from VITA Easyshade.
Median ΔEab* was lowest for the DSLR (0.52), followed by the Pixel (0.80), iPhone (0.89) and Samsung (1.08), and the four cameras differed overall (Friedman χ2(3) = 30.89, p < 0.001; Kendall’s W = 0.355). The DSLR had lower errors than each smartphone after Holm adjustment (all p ≤ 0.002), and the Pixel had lower errors than the Samsung (p = 0.009). The Pixel–iPhone (p = 0.336) and iPhone–Samsung (p = 0.053) comparisons were not significant (Supplementary Table S13).
Every camera stayed within 2.7 for all 29 tabs (exact 95% CI 88.1–100%). The share of tabs within the stricter 1.2 threshold was 100%, 82.8%, 75.9% and 58.6% for the DSLR, Pixel, iPhone and Samsung. No statistically significant mean coordinate differences were detected: the five modalities did not differ in L*, a* or b* (Friedman p = 0.889, 0.946 and 0.587), and all twelve exploratory mean-bias TOST assessments fell within the ±1.2 margin (Supplementary Table S1a). This describes average bias, not agreement for each tab.
For 29/29 tabs below the selected benchmark, the exact 95% interval was 88.1–100.0%. This is a descriptive binomial summary of the fixed complete shade-guide set, not evidence from a random sample of all possible tooth colors.
Repeatability was best for the Easyshade and the DSLR and worst for the Samsung. The median ΔEab* between repeated readings of the same tab was 0.33 for the Easyshade, 0.53 for the DSLR, 0.90 for the Pixel, 1.05 for the iPhone and 1.35 for the Samsung, and ICCs ranged from 0.83 to 0.999 (Supplementary Table S2a). Bland–Altman limits of agreement stayed within ±1.5 units for the DSLR, Pixel and iPhone in all three coordinates, and went beyond it only for Samsung L* (−1.56 to 1.94) and b* (−1.55 to 1.47) (Supplementary Table S3a and Figure S1). Single-image errors were slightly larger than replicate-mean errors, most visibly for the Samsung, where two tabs exceeded 2.7 in two of the three replicate series (Figure 12) (Supplementary Table S5).
Figure 12. Laboratory ΔEab* calculated from replicate-mean coordinates for 29 tabs. Points represent tabs; boxes show medians and interquartile ranges, with whiskers extending to observations within 1.5 IQR. Dashed lines mark the 1.2 and 2.7 thresholds.

3.2. Clinical Study

The 100 participants (56 women and 44 men; aged 20–74 years, mean 49.1 ± 15.6) each had three readings with every modality, and all were included in the paired analyses.
Median ΔEab* was 0.68 for the DSLR, 1.07 for the Pixel, 1.27 for the iPhone and 1.69 for the Samsung (Table 2), and the cameras differed overall (Friedman χ2(3) = 112.96, p < 0.001; W = 0.377). The DSLR had lower errors than each smartphone, and the Pixel and iPhone had lower errors than the Samsung (all adjusted p < 0.001). The Pixel–iPhone difference was borderline (adjusted p = 0.050).
Table 2. Clinical color differences from VITA Easyshade.
At the ΔEab* ≤ 2.7 benchmark, the proportions were 100% for DSLR and Pixel (100/100 each; exact 95% CI 96.4–100.0%), 99% for iPhone (99/100; 94.6–100.0%) and 83% for Samsung (83/100; 74.2–89.8%) (Cochran’s Q(3) = 46.44, p < 0.001). Samsung was lower than each other device (all adjusted p < 0.001), and the remaining pairs did not differ. At the ΔEab* ≤ 1.2 benchmark, the proportions were 95%, 59%, 44% and 32%, respectively (Figure 13).
Figure 13. Clinical ΔEab* for 100 participants. Each point represents one participant using replicate-mean coordinates; plotting conventions match Figure 12.
As in the laboratory, no camera showed a significant mean bias, the five modalities did not differ in any coordinate (Friedman p = 0.997, 0.502 and 0.344), and all exploratory mean-bias TOST assessments met the ±1.2 margin (Supplementary Table S1b). Individual differences were more spread out than these averages suggest. Limits of agreement stayed within ±1.5 for the DSLR in all coordinates but went beyond it for L* with the Pixel (−1.73 to 1.67), for L* and b* with the iPhone, and for L* and b* with the Samsung (L* −2.82 to 2.85; b* −2.25 to 2.25) (Supplementary Table S3b and Figure S2). Small proportional biases were present for a* (Pixel, iPhone, Samsung) and b* (iPhone, Samsung). Repeatability was similar across all devices (median ΔEab* between repeated readings 0.17–0.19), and single-image results were close to the replicate-mean results (Supplementary Tables S2b and S5).
Although average coordinate differences were small, the dispersion of individual differences varied by device. Clinical limits of agreement included −1.73 to 1.67 for Pixel L*, −2.82 to 2.85 for Samsung L*, and −2.25 to 2.25 for Samsung b*. Consequently, the findings on average bias do not establish that the photographic workflows are interchangeable with the reference for individual patients. These limits concern replicate-mean coordinates and do not automatically describe single-image use.

3.3. Prosthodontist Evaluation

The eight prosthodontists produced 928 laboratory and 3200 clinical ratings, with no missing scores. Mean scores ranked the devices in the same order in both phases: DSLR, Pixel, iPhone, Samsung (Table 3). Most ratings were 3 or higher (Supplementary Figures S3 and S4), but agreement among raters was low: ordinal α was 0.03–0.15 in the laboratory and 0.12–0.47 clinically, and the intervals for laboratory DSLR and iPhone included zero. Specimen-level median scores fell as ΔEab* rose for every device and phase (Spearman ρ from −0.43 to −0.70 in the laboratory and from −0.54 to −0.87 clinically). Specimen-average scores differed among devices in both phases (Friedman χ2(3) = 24.40 in the laboratory and 77.69 clinically, both p < 0.001; Kendall’s W 0.280 and 0.259), and all pairwise differences were significant after Holm adjustment except Pixel versus iPhone (Supplementary Table S4).
Table 3. Visual scores and inter-rater reliability.

3.4. In Silico Study

Predictions for the 100 participants and four devices came from a single five-fold, participant-level partition (20 participants per fold) and are averages over three random seeds (Supplementary Table S10).
Neither Random Forest nor ridge regression improved on the calibrated photographic coordinates (Table 4). Random Forest medians were 0.67 for the DSLR, 1.09 for the Pixel, 1.24 for the iPhone and 1.70 for the Samsung, which differ from calibrated baseline by −0.007, +0.020, −0.025 and +0.007. None of the comparisons with calibrated baseline or ridge predictions was significant (all adjusted p ≥ 0.797), and every bootstrap interval for the difference in medians included zero (Supplementary Table S14). The proportion within 2.7 did not change (100%, 100%, 99% and 83%), and no device met the exploratory performance criteria (Supplementary Table S11). A constant predictor was much worse (median ΔEab* 4.41), and the mean-offset correction behaved like the calibrated baseline values (Supplementary Table S6).
Table 4. Color errors of calibrated photographic values and model-corrected predictions.
The exploratory CNN lowered the median error for the DSLR (0.57; difference from calibrated baseline −0.108, 95% CI −0.126 to −0.063) and Pixel (0.90; −0.162, −0.199 to −0.116), but changed it little for the iPhone (1.17; −0.096, −0.175 to 0.036) and Samsung (1.66; −0.033, −0.195 to 0.296). On the two phones it also produced large errors: 13 iPhone and 23 Samsung predictions exceeded 2.7, with maxima of 7.89 and 6.83. As a result, the proportion within 2.7 fell to 87% and 77%, from 99% and 83% for the calibrated baseline values. All DSLR and Pixel predictions remained within 2.7 (Figure 14). Coordinate-level errors, calibration and CIEDE2000 results are in Supplementary Tables S7a–d and S9.
Figure 14. (Left): median ΔEab* for gray-card-calibrated photographic measurements before AI correction (labelled “Raw” in the graphic) and model predictions. (Right): CNN risk–coverage curves obtained by retaining predictions in ascending order of uncertainty score. Risk is the fraction exceeding ΔEab* = 2.7. These descriptive curves are separate from the fold-specific threshold evaluation in Table 5.
Table 5. CNN flags using fold-specific thresholds.

Uncertainty Flags

The fold-specific thresholds (1.949–2.036) flagged 3%, 10%, 22% and 24% of DSLR, Pixel, iPhone and Samsung predictions (Table 5). CNN uncertainty flags detected 11 of 13 iPhone errors above ΔEab* = 2.7 (sensitivity 84.6%; exact 95% CI 54.6–98.1%) and 18 of 23 Samsung errors (78.3%; 56.3–92.5%). These exploratory findings were obtained at one center under controlled acquisition conditions and require external validation before clinical use. Specificity was 87.4% for iPhone and 92.2% for Samsung. DSLR and Pixel had no above-threshold errors, so sensitivity was not estimable. Among unflagged predictions, 97.4% (iPhone) and 93.4% (Samsung) were within 2.7, with 78% and 76% of predictions retained; two iPhone and five Samsung errors remained undetected (Supplementary Table S15). The exact binomial intervals are descriptive and conditional on the available out-of-fold predictions; they do not capture all model-development uncertainty from overlapping training sets.
Uncertainty flagging mitigated some CNN failures but did not establish an advantage over the calibrated photographic baseline. The approach withheld 22% of iPhone and 24% of Samsung predictions while leaving two and five above-threshold errors undetected. Comparisons restricted to retained predictions are affected by selection and reduced coverage. Clinical usefulness requires evaluation against simpler workflows at comparable coverage, including the consequences of rejecting a prediction.
The CNN’s uncertainty score separated above-threshold from below-threshold predictions well (AUROC 0.978, 95% CI 0.941–1.000, for the iPhone; 0.968, 0.934–0.991, for the Samsung), whereas the Mahalanobis distance of the calibrated photographic coordinates did not (0.419 and 0.491; paired AUROC differences 0.559 and 0.477, both intervals excluding zero). The Random Forest’s uncertainty score was no better than chance for the Samsung (AUROC 0.501), and the iPhone had only one Random Forest error (Supplementary Table S16).

4. Discussion

In this laboratory and clinical comparison, the DSLR agreed most closely with the contact spectrophotometer, with a median ΔEab* of 0.52 on shade tabs and 0.68 on natural incisors. Its errors were lower than those of every smartphone in both phases, and all 100 clinical readings fell within the 2.7 acceptability threshold [25]. The hypotheses split in an informative way. The null hypothesis of no difference in CIELAB coordinates among the modalities was not rejected in either phase, and every camera met the exploratory coordinate-wise TOST criterion for small mean bias; this does not establish absolute trueness or individual interchangeability. The null hypothesis of no difference in ΔEab* among the four cameras was rejected in both phases. In other words, the devices differed in how far individual measurements strayed from the reference, which is what matters when one shade has to be chosen for one patient. A ranking with the DSLR ahead of smartphones is in line with earlier comparisons [14,23], although those studies used different references, lighting and outcome measures, so the figures cannot be compared directly.
Smartphone measurements frequently fell below the selected acceptability benchmark, but this did not establish interchangeability. The Pixel and iPhone kept 100% and 99% of clinical readings within 2.7, yet only 59% and 44% were within the stricter 1.2 threshold, against 95% for the DSLR. The Samsung left 17% of participants above 2.7 and had the widest limits of agreement, particularly for L*. These results fit reports that RAW smartphone photographs can approximate spectrophotometric values under controlled conditions [12], while also supporting the view that performance depends on the device and the workflow [18]. Phones differ in how they handle RAW files. Apple ProRAW, for instance, combines RAW sensor information with image processing [21], so a file labelled RAW is not necessarily untouched, and this may account for part of the difference between phones. Because lighting, distance and white balance were tightly controlled here, the results show what these phones can do under good conditions rather than what they would do chairside.
Soldo et al. [12] evaluated RAW smartphone photographs of maxillary central incisors in 30 participants under different lighting configurations, with and without gray-card calibration. Their findings emphasize the combined effects of lighting and calibration; favorable findings for a polarized, uncalibrated configuration cannot be generalized to every smartphone protocol. Our comparison used diffuse lateral illumination and normalized photographs, so numerical differences between studies cannot be attributed to camera hardware alone.
The pilot study by Saincher et al. [24] examined DSLR, point-and-shoot and mobile photography in casts and participants using color and image-quality outcomes. Differences in acquisition and outcome definitions limit direct comparison with our spectrophotometer-referenced ΔE values. Conversely, Moussa et al. [36] assessed linear tooth dimensions in photographs of plaster models; that study supports discussion of photographic geometry, not claims about colorimetric accuracy.
Errors relative to the reference were larger in participants than on shade tabs for every photographic workflow (for example, median ΔEab* 1.08 versus 1.69 for Samsung). Natural teeth differ from shade tabs in translucency, curvature and moisture, but the design cannot separate specimen effects from acquisition effects. Easyshade repeat measurements differed by a median ΔEab* of 0.33 on tabs and 0.18 clinically. These values describe short-term repeatability, not standard uncertainty or calibration bias, and do not establish a lower bound on camera–reference differences. Reference variability contributes to the observed disagreement, along with photographic error, systematic bias and differences in sampling area and geometry. The findings therefore concern relative agreement with this reference instrument, rather than absolute tooth-color accuracy.
Photographic repeatability was poorer in the laboratory (median replicate ΔEab* 0.53–1.35) than clinically (0.17–0.19). This difference cannot be assigned a demonstrated cause without checking repositioning and calculation records. Short-interval repeatability and reference agreement measure different properties: closely repeated images can retain a systematic difference from Easyshade.
The prosthodontists rated almost every photograph as acceptable, yet agreement between them was low (clinical α 0.12–0.47). Part of this is statistical, since α is small when most ratings sit at 4 or 5 and there is little variance to explain, but it also matches the known unreliability of visual shade assessment [8,9]. Even so, specimen-level scores followed the instrument. They fell as ΔEab* rose for every device, and the Samsung, with the largest errors, received the lowest scores and the highest α. Visual judgment of a photograph therefore seems to track instrumental error when errors are large, but to discriminate poorly when they are small, which is consistent with the argument for using an instrument alongside visual matching [28].
Neither Random Forest nor ridge regression improved on the gray-card-calibrated coordinates. Changes in median error were at most 0.03 ΔEab*, none was significant, and no device met the exploratory performance criteria. Residual error after normalization may not be predictable from three color coordinates, but this explanation was not directly tested. The constant predictor performed much worse (median ΔEab* 4.41), so narrow clustering of incisor colors does not by itself explain baseline agreement. Kim et al. [27] combined a purpose-built, cross-polarized imaging system with color calibration and SVM classification of shade tabs. Their favorable classification performance addresses a different task from correcting continuous CIELAB coordinates of natural teeth after gray-card normalization. Our findings therefore question the added benefit of the tested correction models in this dataset, rather than the usefulness of machine learning for all shade-assessment tasks.
All models in this study were evaluated after gray-card normalization. Their performance without that step is unknown. A future paired comparison should evaluate both normalized and non-normalized images under identical participant-level validation splits to determine whether AI offers additional value in a simplified clinical workflow.
The CNN lowered the median error for the DSLR and Pixel, but on iPhone and Samsung images it produced occasional large errors, up to 7.89 ΔEab*, and the share of predictions within 2.7 ended up below that of the calibrated photographic values (87% versus 99% and 77% versus 83%). Our data do not show why. One possibility is that processing-dependent color shifts in phone images are hard to learn from 80 training participants per fold; another is that a few unusual images pushed the network outside what it had seen. The Random Forest produced no such errors, but it also left the calibrated photographic values almost unchanged, which does not establish a clinical safety advantage. With 100 participants and a pretrained network, the CNN should be regarded as exploratory, and the results may not hold with more data.
Uncertainty flagging mitigated some CNN failures but did not establish an advantage over the calibrated photographic baseline. The approach withheld 22% of iPhone and 24% of Samsung predictions while leaving two and five above-threshold errors undetected. Comparisons restricted to retained predictions are affected by selection and reduced coverage. Clinical usefulness requires evaluation against simpler workflows at comparable coverage, including the consequences of rejecting a prediction. The flags primarily identify failures introduced by the tested CNN. A matched-coverage comparison, a defined fallback process and independent validation are needed to establish added clinical value. A gray-card-calibrated DSLR workflow achieved close reference agreement without AI-based correction.
This study has several limitations. The clinical convenience sample came from one center and included one healthy anterior tooth per participant. Results may not apply to restored, stained or discolored teeth, and the age range (20–74 years) was not stratified. Acquisition used controlled LED lighting, a gray reference card and manual Camera Raw normalization; performance under mixed ambient light is uncertain. Device hardware, exposure, optics and processing were not varied independently, so the ranking applies to the complete tested workflows. A photographic sampling window is not necessarily equivalent to the probe’s physical measurement area. The reference instrument is not ground truth, and perceptual thresholds do not establish instrument interchangeability [25]. No formal sample-size calculation was performed; the clinical convenience sample and fixed laboratory shade set limit generalization. A numerical uncertainty budget and the unresolved processing and replicate-acquisition details require verification from original records.
The AI models were developed and internally validated using a single-center dataset of 100 participants; no external validation or independent verification was performed. Results may vary with patient characteristics, operators, lighting, devices and processing software, and a single cross-validation partition does not capture all sources of model-development variability. All eight visual evaluators were prosthodontists from the same institution, potentially sharing training and assessment conventions. Their ratings may not generalize to other practitioners, dental technicians or patients. Multicenter evaluation with independent operators and a more diverse evaluator panel is needed.

5. Conclusions

Within the limits of this single-center study:
  • The gray-card-calibrated DSLR workflow showed the closest agreement with the reference spectrophotometer, with median ΔEab* values of 0.52 on shade tabs and 0.68 in participants, without AI-based correction.
  • Pixel and iPhone measurements were within the ΔEab* ≤ 2.7 benchmark in 100% and 99% of participants, but within the ≤ 1.2 benchmark in only 59% and 44%, respectively. Samsung exceeded 2.7 in 17% of participants. These proportions describe agreement relative to selected perceptual benchmarks under the tested workflows; they do not establish instrument interchangeability or acceptable final restorations.
  • Random Forest and ridge correction did not improve on the gray-card-calibrated coordinates.
  • The exploratory CNN lowered median error for DSLR and Pixel but introduced large errors in some smartphone predictions. CNN uncertainty flags detected 11 of 13 iPhone errors above ΔEab* = 2.7 (sensitivity 84.6%; exact 95% CI 54.6–98.1%) and 18 of 23 Samsung errors (78.3%; 56.3–92.5%). These exploratory findings were obtained at one center under controlled acquisition conditions and require external validation before clinical use. Flagging withheld 22% and 24% of iPhone and Samsung predictions, left two and five errors undetected, and did not demonstrate added value over the calibrated photographic baseline.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/dj14120773/s1, Table S1a: Coordinate biases and mean equivalence-Laboratory coordinate comparisons; Table S1b: Coordinate biases and mean equivalence-Clinical coordinate comparisons; Table S2a: Repeatability of three readings-Laboratory repeatability; Table S2b: Repeatability of three readings-Clinical repeatability; Table S3a: Limits of agreement and proportional bias-Laboratory Bland Altman agreement; Figure S1. Laboratory Bland; Table S3b. Limits of agreement and proportional bias-Clinical Bland Altman agreement; Figure S2: Clinical Bland; Table S4: Visual score pairwise comparisons; Table S5: Single image sensitivity analysis; Table S6: Descriptive model comparisons; Table S7a: Coordinate errors and calibration-DSLR model coordinate performance; Table S7b: Coordinate errors and calibration-Pixel model coordinate performance; Table S7c: Coordinate errors and calibration-iPhone model coordinate performance; Table S7d: Coordinate errors and calibration-Samsung model coordinate performance; Table S8a: Upper-tail errors and threshold precision-Prediction precision and tail errors; Table S8b: Upper-tail errors and threshold precision; Table S9: CIEDE2000 errors against VITA Easyshade; Table S10: Recorded validation folds and baseline audit; Table S11: Acceptability component of Random Forest success criteria; Table S12: Distributional check for paired color-error differences; Table S13: Paired comparisons of photographic devices; Table S14: Random Forest comparisons with raw and ridge estimates; Table S15: Acceptability after applying CNN uncertainty flags; Table S16: Uncertainty discrimination compared with Mahalanobis distance; Figure S3: Distribution of the 232 laboratory ratings per device on the five-point visual scale; Figure S4: Distribution of the 800 clinical ratings per device. Ratings of 3–5 were classified as acceptable in this study; Figure S5: Risk–coverage curves for CNN and RF uncertainty scores, compared with Mahalanobis distance for the corresponding model’s error outcome.

Author Contributions

M.A.A. and B.A.A. conducted the laboratory and clinical studies, R.E. conducted the statistical analysis and the AI study. Conceptualization, M.A.A., B.A.A. and R.E.; methodology, M.A.A., B.A.A. and R.E.; software, M.A.A., B.A.A. and R.E.; validation, M.A.A., B.A.A. and R.E.; formal analysis, R.E.; investigation, M.A.A., B.A.A. and R.E.; resources, M.A.A., B.A.A. and R.E.; data curation, R.E.; writing—original draft preparation, M.A.A., B.A.A. and R.E.; writing—review and editing, M.A.A., B.A.A. and R.E.; visualization, M.A.A., B.A.A. and R.E.; supervision, M.A.A.; project administration, M.A.A.; funding acquisition, M.A.A. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

The research protocol was conducted in strict adherence to the Declaration of Helsinki and approved by the Institutional Review Board and Ethics Committee of the College of Dentistry, Qassim University (IRB: QUDENT25-02-26) on 25 February 2026.

Data Availability Statement

The raw data supporting the conclusions of this article will be made available by the authors on request.

Acknowledgments

The researchers would like to thank the Deanship of Graduate Studies and Scientific Research at Qassim University (www.qu.edu.sa) for financial support (QU-APC-2026). During preparation of this manuscript, the authors used ChatGPT (GPT6-Astra, OpenAI) to assist with English writing and creation of the graphical abstract. The authors reviewed and edited the output and take full responsibility for the content of this publication.

Conflicts of Interest

The authors declare no conflicts of interest.

Abbreviations

AIArtificial intelligence
ATAcceptability threshold
AUROCArea under the receiver operating characteristic curve
CIConfidence interval
CIEInternational Commission on Illumination
CIELABCIE L*a*b* color space
CNNConvolutional neural network
CRIColor rendering index
DNGDigital Negative image file format
DSLRDigital single-lens reflex
ICCIntraclass correlation coefficient
IQRInterquartile range
IRBInstitutional Review Board
LEDLight-emitting diode
MAEMean absolute error
NENot estimable
PTPerceptibility threshold
RFRandom Forest
RGBRed, green, and blue
RMSERoot mean squared error
SDStandard deviation
sRGBStandard red, green, and blue color space
TOSTTwo one-sided tests
L*CIELAB lightness coordinate
a*CIELAB red–green coordinate
b*CIELAB yellow–blue coordinate
ΔEab*Euclidean color difference in CIELAB color space
ΔE00Color difference calculated using the CIEDE2000 formula
P9595th percentile
SwWithin-subject standard deviation
Kendall’s WKendall’s coefficient of concordance
Krippendorff’s αKrippendorff’s coefficient of inter-rater reliability
Spearman’s ρSpearman’s rank correlation coefficient

References

  1. Nandhra, K.; Woolley, J.; Bister, D.; Sherriff, M.; Jeremiah, H. Smartphones or digital SLRs for clinical dental photography: Is there a difference? Eur. J. Orthod. 2025, 47, cjaf033. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  2. Gupta, R.; Tomer, A.K.; George, M.; Saurabh, S.; Chandaran, A.V.; Krishnakumar, K.; Reddy, A.P.; Modinagar, G. Smartphones: The Future of Smart Dentistry. Int. J. Dent. Res. 2023, 8, 15–17. [Google Scholar] [CrossRef] [Scilit]
  3. Kargozar, S.; Jadidfard, M.P. Teledentistry accuracy for caries diagnosis: A systematic review of in-vivo studies using extra-oral photography methods. BMC Oral Health 2024, 24, 828. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  4. Godlevsky, L.; Bidnyuk, E.; Bayazitov, N.; Kresyun, N.; Kovalenko, A.; Lyashenko, A.; Balyko, V. Application of mobile photography with smartphone cameras for monitoring of early caries appearance in the course of orthodontic correction with dental brackets. Appl. Med. Inform. 2013, 33, 21–26. [Google Scholar]
  5. Farook, T.H.; Ahmed, S.; Jamayet, N.B.; Dudley, J. Computer vision with smartphone microphotography for detection of carious lesions. Intell. Based Med. 2023, 8, 100105. [Google Scholar] [CrossRef] [Scilit]
  6. Son, Y.T.; Son, K.; Eo, G.O.; Lee, K.B. Feasibility of images acquired using smartphone camera for marginal and internal fit of fixed dental prosthesis: Comparison and correlation study. Sci. Rep. 2024, 14, 5291. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  7. Hein, S.; Tapia, J.; Bazos, P. eLABor_aid: A new approach to digital shade management. Int. J. Esthet. Dent. 2017, 12, 186–202. [Google Scholar] [PubMed]
  8. Hardan, L.; Bourgi, R.; Cuevas-Suárez, C.E.; Lukomska-Szymanska, M.; Monjaras-Avila, A.J.; Zarow, M.; Jakubowicz, N.; Jorquera, G.; Ashi, T.; Mancino, D.; et al. Novel trends in dental color match using different shade selection methods: A systematic review and meta-analysis. Materials 2022, 15, 468. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  9. Rashid, F.; Farook, T.H.; Dudley, J. Digital shade matching in dentistry: A systematic review. Dent. J. 2023, 11, 250. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  10. Llena, C.; Lozano, E.; Amengual, J.; Forner, L. Reliability of Two Color Selection Devices in Matching and Measuring Tooth Color. J. Contemp. Dent. Pract. 2011, 12, 19–23. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  11. Naffah, N.; Ounsi, H.; Özcan, M.; Salameh, Z. Evaluation of the Color Stability of Three Resin-Ceramic Materials Using a Spectrophotometer and a Digital Photography Software. Contemp. Clin. Dent. 2024, 15, 44–50. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  12. Soldo, M.; Illeš, D.; Ćelić, R.; Knezović Zlatarić, D. Assessment of Color Parameters on Maxillary Right Central Incisors Using Spectrophotometer and RAW Mobile Photos in Different Light Conditions. Acta Stomatol. Croat. 2020, 54, 353–362. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  13. Lazar, R.; Culic, B.; Gasparik, C.; Lazar, C.; Dudea, D. Evaluation of smartphone dental photography in aesthetic analysis. Br. Dent. J. 2021, 231, 427–434. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  14. Antar, F.; Zebouni, E. Comparative review of DSLR cameras and smartphones in dental photography: Indications and limitations. Int. Arab. J. Dent. 2018, 9, 107–115. [Google Scholar]
  15. Moussa, R. Dental Shade Matching: Recent technologies and future smart applications. J. Dent. Health Oral Res. 2021, 2, 1–10. [Google Scholar] [CrossRef] [Scilit]
  16. Tam, W.K.; Lee, H.J. Accurate shade image matching by using a smartphone camera. J. Prosthodont. Res. 2017, 61, 168–176. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  17. Chaware, S.H.; Borse, S.V.; Kakatkar, V.; Darekar, A. Clinical Performance of Newly Developed Android Mobile Digital Application on Tooth Shade Reproduction: A Multicenter Randomized Controlled Clinical Trial. Contemp. Clin. Dent. 2023, 14, 3–10. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  18. Dudkiewicz, K.; Łacinik, S.; Jedliński, M.; Janiszewska-Olszowska, J.; Grocholewicz, K. A Clinician’s Perspective on the Accuracy of the Shade Determination of Dental Ceramics—A Systematic Review. J. Pers. Med. 2024, 14, 252. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  19. Lee, L.T.; Zulkiflee, N.E.; Bakar, N.A. Comparison of the perceived image quality of intraoral orthodontic photographs taken with DSLR camera and mobile phone camera: A double-blinded prospective study. IIUM J. Orofac. Health Sci. 2024, 5, 153–163. [Google Scholar] [CrossRef] [Scilit]
  20. Solanki, H.; Sodani, V.; Sarvaiya, B.; Sharma, D.; Chauhan, K.; Shah, R. Comparative Evaluation of Effectiveness and Preferences between Smartphone Cameras vs. DSLRs in Clinical Dental Photography. J. Adv. Med. Dent. Sci. Res. 2024, 12, 38–42. [Google Scholar]
  21. Apple Inc. About Apple ProRAW. Apple Support. Published 19 April 2024. Available online: https://support.apple.com/en-us/119916 (accessed on 13 September 2026).
  22. Corciolani, G.; Vichi, A.; Goracci, C.; Ferrari, M. Colour correspondence of a ceramic system in two different shade guides. J. Dent. 2009, 37, 98–101. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  23. Shrestha, P.; Poudel, S. Comparison between mobile camera and DSLR camera photography for the evaluation of shade of anterior teeth-A cross-sectional study. J. Chitwan Med. Coll. 2019, 9, 111–119. [Google Scholar] [CrossRef] [Scilit]
  24. Saincher, R.; Kumar, S.; Gopalkrishna, P.; Maithri, M.; Sherigar, P. Comparison of color accuracy and picture quality of digital SLR, point and shoot and mobile cameras used for dental intraoral photography–A pilot study. Heliyon 2022, 8, e09249. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  25. Paravina, R.D.; Ghinea, R.; Herrera, L.J.; Bona, A.D.; Igiel, C.; Linninger, M.; Sakai, M.; Takahashi, H.; Tashkandi, E.; Perez, M.d.M. Color difference thresholds in dentistry. J. Esthet. Restor. Dent. 2015, 27, S1–S9. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  26. Moazam, R.M.Z.H.; Ghani, Z.A.; Ahmad, W.M.A.W.; Halim, M.S.; Jamayet, N.B.; Rawas, M.Z.A. Tooth Color Differences between Digital Photography and Spectrophotometer in both Genders: An In Vivo Study. Open Dent. J. 2023, 17, e187421062308080. [Google Scholar] [CrossRef] [Scilit]
  27. Kim, M.; Kim, B.; Park, B.; Lee, M.; Won, Y.; Kim, C.Y.; Lee, S. A digital shade-matching device for dental color determination using the support vector machine algorithm. Sensors 2018, 18, 3051. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  28. Menini, M.; Rivolta, L.; Manauta, J.; Nuvina, M.; Kovacs-Vajna, Z.M.; Pesce, P. Dental color-matching ability: Comparison between visual determination and technology. Dent. J. 2024, 12, 284. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  29. Collins, G.S.; Moons, K.G.M.; Dhiman, P.; Riley, R.D.; Beam, A.L.; Van Calster, B.; Ghassemi, M.; Liu, X.; Reitsma, J.B.; van Smeden, M.; et al. TRIPOD+AI statement: Updated guidance for reporting clinical prediction models that use regression or machine learning methods. BMJ. 2024, 385, e078378. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  30. Gal, Y.; Ghahramani, Z. Dropout as a Bayesian approximation: Representing model uncertainty in deep learning. In Proceedings of the 33rd International Conference on Machine Learning, New York, NY, USA, 20–22 June 2016; Proceedings of Machine Learning Research; PMLR: New York, NY, USA, 2016; Volume 48, pp. 1050–1059. Available online: https://proceedings.mlr.press/v48/gal16.html (accessed on 1 September 2025).
  31. Koo, T.K.; Li, M.Y. A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research. J. Chiropr. Med. 2016, 15, 155–163. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  32. Lakens, D. Equivalence tests: A practical primer for t tests, correlations, and meta-analyses. Soc. Psychol. Pers. Sci. 2017, 8, 355–362. [Google Scholar]
  33. Bland, J.M.; Altman, D.G. Measuring agreement in method comparison studies. Stat. Methods Med. Res. 1999, 8, 135–160. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  34. Joint Committee for Guides in Metrology. Evaluation of Measurement Data—Guide to the Expression of Uncertainty in Measurement; JCGM 100:2008; JCGM: Geneva, Switzerland, 2008. [Google Scholar] [CrossRef] [Scilit]
  35. Joint Committee for Guides in Metrology. Evaluation of measurement Data—Supplement 1 to the Guide to the Expression of Uncertainty in Measurement—Propagation of Distributions Using a Monte Carlo Method; JCGM 101:2008; JCGM: Geneva, Switzerland, 2008. [Google Scholar] [CrossRef] [Scilit]
  36. Moussa, C.; Hardan, L.; Kassis, C.; Bourgi, R.; Devoto, W.; Jorquera, G.; Panda, S.; Abou Fadel, R.; Cuevas-Suárez, C.E. Accuracy of dental photography: Professional vs. smartphone’s camera. Biomed. Res. Int. 2021, 2021, 3910291. [Google Scholar] [CrossRef] [Scilit] [PubMed]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.