Skip to Content
Dentistry JournalDentistry Journal
  • Article
  • Open Access

23 November 2026

12 Pages

Effect of Hydration Methods on Epithelial Integrity of Gingival Tissues: A Pilot Histological Study

,
,
,
,
and
1
Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Arbor, MI 48109, USA
2
Oral and Maxillofacial Pathology Biopsy Service, University of Michigan, Ann Arbor, MI 48109, USA
*
Author to whom correspondence should be addressed.
Dent. J.2026, 14(12), 768;https://doi.org/10.3390/dj14120768 
(registering DOI)
This article belongs to the Special Issue Advances in Periodontal and Peri-Implant Tissues Health Management: 2nd Edition

Abstract

Background/Objectives: To evaluate the effect of hydration methods and duration on the epithelial integrity of soft tissue harvested during periodontal surgery. Methods: Eighty soft-tissue samples containing epithelium and its underlying connective tissue were collected from 10 patients undergoing periodontal surgery. Forty samples served as paired controls (no-medium group, NM), 20 were assigned to be submerged in saline (SSG), and 20 were interposed between two layers of saline-moistened gauze (MGG). Samples were removed at 5 (T1), 15 (T2), 30 (T3), and 60 min (T4) and immediately processed. Samples were embedded, sectioned, and stained with hematoxylin and eosin (H&E). Two blinded examiners performed a histologic assessment of epithelial integrity, including epithelial continuity, tissue architecture, and epithelial detachment. Results: After exclusion, 66 specimens were assessed histologically (NM = 32, SSG = 20, MGG = 14). At T3, epithelial integrity was preserved in 80% of SSG, 50% of MGG, and 12.5% of NM specimens. In the paired analysis, saline storage preserved epithelial integrity significantly better than NM at T3 (p = 0.031). No significant differences were observed at T1 or T2. At T4, epithelial degradation was evident across all groups. SSG and MGG did not differ significantly at any timepoint. Conclusions: Saline-based hydration effectively preserves epithelial integrity up to 30 min, suggesting a clinically relevant window for optimal graft manipulation and transplantation. Extended hydration results in progressive degradation regardless of hydration method, highlighting the importance of timely tissue processing and transfer.

Article Metrics

Citations

Article Access Statistics

Article metric data becomes available approximately 24 hours after publication online.