Abstract
Pulsed laser loading enables particle delivery into vacuum optical tweezers, but successful capture alone does not establish whether the measured response supports quantitative characterization. Here, we assess post-capture spectral consistency using aerosol-loaded silica as an empirical reference. Power spectral densities from twenty reference particles and twenty objects loaded from an aluminum substrate carrying silica nanoparticles were examined over 1–10 mbar. Applicability of the peak-fitting model was assessed before parameter comparison, with relative fit uncertainty indicating the precision of admissible estimates. At 5 mbar, recordings were available for all twenty laser-loaded objects, and twelve supported quantitative fitting. Their mean fitted linewidth parameter was 27.13 ± 9.07 kHz, compared with 7.24 ± 2.38 kHz for the twenty reference particles (mean ± standard deviation), giving a ratio of 3.75. Additional bare-Al and DMSO-treated bare-Al controls each yielded 6 of 20 model-applicable spectra at 5 mbar, with mean fitted linewidths of 31.94 ± 6.40 and 27.80 ± 5.12 kHz, respectively; neither control showed a significant linewidth difference from the SiO2-coated laser-loaded group. Registered scanning electron microscopy revealed retained, disappeared, and newly visible particulate features on the substrate after irradiation. These results show that successful capture does not necessarily yield a spectrum suitable for model-based characterization. Comparison with an independently loaded SiO2 reference, together with the substrate-control measurements, provides a direct basis for evaluating the spectral response of pulsed-laser-loaded objects.
1. Introduction
Optically levitated particles are used in precision sensing and studies of mechanical motion in vacuum [1,2]. Applications include weak-force detection [3,4], electric-field sensing [5], and low-frequency wireless reception [6]. Controlled coupling between particles [7] and advances in compact and integrated levitation platforms [8,9,10] further extend these applications. Quantitative measurements require both reliable particle delivery and a measured response that supports the intended calibration model.
Nebulization is an established method for loading solid particles into optical traps [11], although the associated gas load and possible solvent deposition motivate alternative methods [12]. These include piezoelectric launching [13], hollow-core fiber transport [14], and microelectromechanical release arrays [15]. Pulsed laser release enables localized delivery from a substrate and has been demonstrated with silicon nanoparticles and nanorods [16,17]. Detachment and capture have also been analyzed theoretically for a pulsed-laser-assisted fiber trap [18]. Bykov et al. combined laser-induced acoustic desorption with a switched Paul trap [19], while Nikkhou et al. demonstrated direct optical loading at millibar pressures [12].
Previous laser-loading studies have examined the properties of captured particles. Nikkhou et al. used scattering signals, motion spectra, and damping estimates to assess trapping events [12]. Troyer et al. combined directional damping measurements with simulations to characterize laser-loaded nanorotors [20]. These approaches rely on an interpretable dynamical response. Pressure-dependent confinement and particle loss during pressure reduction [21,22], nonequilibrium particle–gas interactions [23], and changes in silica surface chemistry or morphology [24,25] can complicate that interpretation. A spectrum that differs from the expected response therefore does not, by itself, identify the composition or morphology of a trapped object.
The same requirement applies to particle metrology. Mass and displacement calibration [26,27], size estimation [28], charge characterization [29], and force sensing and sensor calibration [30,31] depend on appropriate models of the measured response. Power spectral density (PSD) analysis provides a practical initial assessment using signals already acquired during trapping [32,33]. However, thermal nonlinearities [34], non-translational particle motion [35], and optical readout effects [36] can affect the measured spectrum. Before comparing fitted parameters, it is therefore necessary to determine whether a resolvable spectral feature supports the selected model. Comparison with an independently loaded reference population can then establish how the analyzable responses differ under comparable measurement conditions.
Under comparable trapping and pressure conditions, particles of the same nominal material and size are therefore expected to show similar spectral parameters. This is why aerosol-loaded SiO2 particles are used here as an empirical reference.
In this study, we compare the spectra of 20 objects captured after pulsed irradiation of an aluminum substrate carrying silica nanoparticles with those of 20 aerosol-loaded silica reference particles over 1–10 mbar. Additional bare-Al and DMSO-treated bare-Al controls were used to evaluate possible contributions from the substrate and DMSO treatment. We first assess whether each mean PSD supports a single-mode damped harmonic oscillator model, then compare the fitted frequency and effective linewidth parameters and evaluate their fit precision. At 5 mbar, recordings are available for all 20 laser-loaded objects, allowing the 12 model-applicable spectra to be identified within the full recorded group. Registered scanning electron microscopy provides complementary observations of substrate changes. This comparison identifies departures from the reference response before particle properties are inferred.
2. Materials and Methods
2.1. Optical Trapping and Signal Acquisition
We investigated objects captured after pulsed irradiation of an aluminum (Al) substrate carrying silica (SiO2) nanoparticles with a nominal diameter of 150 nm (NANOCYM, Scottsdale, AZ, USA). Aerosol-loaded SiO2 particles of the same nominal diameter served as the reference population. Two control substrates without SiO2 nanoparticles were also examined: a bare Al substrate and a DMSO-treated bare Al substrate. Substrate preparation is described in Supplementary Section S1.
The experimental setup is shown in Figure 1. A custom-built optical levitation probe combined a fiber-coupled optical module with a detachable quartz-glass vacuum chamber. The approximately cylindrical probe was 159 mm long and 28 mm in outer diameter. An optical fiber delivered the trapping light, and a channel at the base connected the chamber to the vacuum system.
Figure 1.
Experimental setup for pulsed laser loading and optical detection. A 1064 nm beam is delivered through a fiber circulator, collimated, and focused by an aspheric lens inside a quartz-glass vacuum chamber. Backscattered light is collected along the same optical path and directed to a balanced photodetector (BPD); the electrical signal is recorded by the data acquisition system (DAQ). A 532 nm pulsed laser illuminates the rear surface of an Al substrate carrying SiO2 nanoparticles. The vacuum chamber and fiber-coupled optical module form a miniaturized probe.
A continuous-wave 1064 nm fiber laser (FLSF-1064-5-CW, Shanghai Precilasers Technology Co., Ltd., Shanghai, China) provided the trapping light. The beam passed through a three-port fiber circulator, was collimated into free space, and was focused by an aspheric lens to form a single-beam optical trap inside the chamber. The lens working distance was 1.48 mm, and the optical power at the trap position was approximately 637 mW.
Backscattered light was collected through the same lens and collimator and coupled into the fiber. The circulator directed the return light to a balanced photodetector (BPD; PDB450C-AC, Thorlabs, Newton, NJ, USA). The electrical signal was recorded using an MFLI lock-in amplifier (Zurich Instruments, Zurich, Switzerland) and used for PSD analysis.
2.2. Pulsed Laser Loading and Pressure Sequence
A 532 nm laser (CC1101, Guangzhou Kedi Mei, Guangzhou, China) with an approximately 15 ns pulse duration was directed onto the rear surface of the Al substrate. The beam passed through an expansion stage with lens focal lengths of 50 and 120 mm and was then focused onto the substrate. The laser spot radius was estimated to be approximately 0.4 mm by measuring the radius of the circular burn mark produced by the pulsed beam on cardboard with a ruler. The pulse fluence was set to approximately 0.37 J cm−2 using the laser-system setting and was not independently measured. The substrate was positioned approximately 1 mm from the trap center.
The laser was operated in manually triggered single-pulse mode, with one pulse delivered per trigger. However, a single pulse did not always result in successful capture, and multiple pulses were sometimes required. Successful capture was identified by observing a bright spot near the trap center in the CCD image together with a corresponding change in the signal recorded by the MFLI lock-in amplifier (Zurich Instruments, Zurich, Switzerland).
Pulsed laser loading from the SiO2-coated substrate was performed at approximately 50 mbar. After capture, the pressure was reduced sequentially to 10, 5, 2, and 1 mbar. Signals were recorded at each pressure while the object remained trapped, and loss during pressure reduction resulted in missing measurements at subsequent pressures. For the control experiments, a bare Al substrate and a DMSO-treated bare Al substrate, both without SiO2 nanoparticles, were used. The same pulsed-laser loading, pressure-reduction, and signal-acquisition procedure was followed for both controls. Twenty successful trapping events were obtained for each control. Reference particles were loaded by aerosol delivery and measured separately at the same four pressures under comparable trapping and detection conditions.
2.3. PSD Estimation and Spectral Model
For each recorded object–pressure combination, 20 independent time traces were acquired at a sampling rate of 937.5 kHz. Each complete trace contained 262,144 samples, corresponding to approximately 0.280 s. When all 20 traces were complete, the total sampled duration was approximately 5.592 s. The traces were acquired separately and were not treated as a continuous time series. When an anomalously short first record was present, that record was excluded and the remaining 19 complete traces were used for analysis. After subtracting the mean of each retained trace, its PSD was calculated using Welch’s method with a Hann window, 16,384 samples per segment, and 50% overlap. The frequency-bin spacing was approximately 57.2 Hz. The PSDs from the retained traces were averaged arithmetically, and all subsequent spectral assessment and fitting used this mean PSD. The same processing procedure was applied to the aerosol-loaded SiO2 reference, SiO2-coated laser-loaded, bare-substrate control, and DMSO-treated bare-substrate control groups. Supplementary Section S2 describes the additional low-pressure measurement excluded from linewidth comparisons.
Resolvable peaks were fitted by nonlinear least squares using the single-mode damped harmonic oscillator spectral model.
Here, f is frequency, f0 is the fitted frequency parameter, γ is the fitted linewidth parameter, A is an amplitude coefficient, and C is a constant background. Both f0 and γ are expressed in Hz. For an ideal linear oscillator, f0 corresponds to the undamped natural frequency. The model approaches a Lorentzian near resonance in the weak-damping limit, where γ approximates the full width at half maximum. These identifications are not assumed for the broad spectra of the laser-loaded objects; their fitted parameters are used as effective spectral descriptors.
2.4. Model Applicability and Fit Precision
In this study, model-applicable indicates that the unsmoothed mean PSD contains a localized spectral feature from which Equation (1) yields stable estimates of the fitted frequency and linewidth. The term refers to parameter identifiability rather than to the physical validity of damped harmonic oscillator dynamics. The same criteria were applied to the aerosol-loaded SiO2 reference, SiO2-coated laser-loaded, bare-substrate control, and DMSO-treated bare-substrate control groups: the main spectral feature had to be identifiable and adequately represented by Equation (1), and the fitted parameters could not be dominated by fitting-window or parameter boundaries. Borderline cases were further checked for fitting-window sensitivity and trace-to-trace repeatability. Numerical convergence alone was not sufficient for inclusion.
The relative linewidth fit uncertainty was defined as
where σγ,fit is the standard error obtained from the parameter covariance matrix of the nonlinear least-squares fit. Thus, Uγ describes the formal precision of γ conditional on the selected model and fitting procedure. It does not measure model validity or total experimental uncertainty.
The 80 model-applicable mean PSDs from the 20 reference particles at four pressures provided an empirical distribution of Uγ. Its 95th percentile, 1.72%, was used as a descriptive benchmark for fit precision. This distribution pools repeated measurements of the same particles across pressures. The benchmark was not used to determine model applicability or to exclude data. A model-applicable spectrum could therefore have Uγ > 1.72% and remain in the parameter comparison.
For the 5 mbar parameter comparisons, one fitted value obtained from the mean PSD of each independent object was included in the analysis. The primary linewidth comparison included 20 aerosol-loaded SiO2 reference particles and 12 model-applicable SiO2-coated laser-loaded objects. Their group means were compared using a two-sided Welch’s two-sample t-test, which does not assume equal variances, and the mean difference and its 95% confidence interval were calculated.
For the bare-substrate control, the model-applicability fraction was compared with those of the SiO2-coated laser-loaded and aerosol-loaded SiO2 reference groups using two-sided Fisher’s exact tests. Fitted linewidth and fitted frequency values from the model-applicable subset were compared with the same two groups using two-sided Welch’s two-sample t-tests. For the DMSO-treated bare-substrate control, the model-applicability fraction was compared with those of the bare-substrate control, SiO2-coated laser-loaded, and aerosol-loaded SiO2 reference groups using two-sided Fisher’s exact tests. Fitted linewidth and fitted frequency values were compared with the same three groups using two-sided Welch’s two-sample t-tests. Holm correction was applied separately within each control analysis for the fitted-parameter comparisons. A p value below 0.05 was considered statistically significant.
3. Results
3.1. Aerosol-Loaded Silica Reference
All 80 mean PSDs from the 20 reference particles were model-applicable. Representative spectra at 1, 2, 5, and 10 mbar are shown in Figure 2a. The peaks broadened as pressure increased, whereas the fitted frequency parameter varied over a narrower range. The linewidth parameters for the 20 particles are summarized in Figure 2b. Across 1–10 mbar, the mean fitted linewidth increased approximately linearly with pressure (R2 = 0.985 for a linear fit to the four pressure-point means). At 5 mbar, the mean was 7.24 ± 2.38 kHz, where the uncertainty denotes the standard deviation across particles. The empirical distribution of Uγ is shown in Figure 2c, with a 95th percentile of 1.72%.
Figure 2.
Spectral response and fit-precision benchmark for aerosol-loaded SiO2 reference particles. (a) Representative mean PSDs at 1, 2, 5, and 10 mbar, with fits to Equation (1) and the corresponding fitted parameters f0 and γ. (b) Fitted linewidth parameter versus pressure for 20 reference particles. Thin lines connect measurements from individual particles; the thick line and error bars show the mean ± standard deviation. (c) Empirical cumulative distribution of Uγ for the 80 mean PSDs. The 95th percentile is 1.72%.
3.2. Spectral Model Applicability After Laser Loading
All 20 laser-loaded objects were recorded at 10 and 5 mbar, with no object loss between these two pressure points. During the reduction from 5 to 2 mbar, 4 of the 20 objects were lost, leaving 16 objects recorded at 2 mbar, corresponding to a stage-wise loss fraction of 20%. Of these 16 objects, 11 were lost before the 1 mbar measurement, leaving five recorded objects at 1 mbar, corresponding to a stage-wise loss fraction of 68.8%. None of the five objects remaining at 1 mbar could be retained to 0.01 mbar. The recorded spectra ranged from identifiable localized features to responses without sufficient spectral structure for reliable peak-based parameter extraction, as illustrated at 5 mbar in Figure 3a.
Figure 3.
Spectral interpretability and classification of laser-loaded objects. (a1) Mean PSD of a representative aerosol-loaded SiO2 reference particle at 5 mbar. (a2) Mean PSD of a model-applicable laser-loaded object (Object 7) at 5 mbar. (a3) Mean PSD of a model-inapplicable laser-loaded object (Object 2) at 5 mbar. The full 0–80 kHz frequency range is shown in panels (a1–a3), with Equation (1) fits overlaid where reliable peak-based parameter extraction was supported. (b) Recording status and model applicability for the 20 laser-loaded objects during sequential pressure reduction. Blue indicates model-applicable, gray model-inapplicable, and hatching loss of the object before the corresponding measurement. The recorded/model-applicable counts are 20/1, 20/12, 16/15, and 5/4 at 10, 5, 2, and 1 mbar, respectively.
The full 0–80 kHz spectrum of Object 2 was examined to determine whether a localized feature was present below the frequency range displayed previously. As shown in Figure 3a3, its low-frequency region remains dominated by continuous background variation and no distinct localized peak is resolved. Object 2 was therefore retained as a model-inapplicable example. In contrast, Object 7 exhibits a broad but identifiable localized feature that is adequately described by Equation (1) and was retained for parameter extraction.
The recording and classification results are summarized in Figure 3b. At 10 mbar, one of the 20 laser-loaded spectra supported stable parameter extraction. At 5 mbar, 12 of the 20 recorded spectra were model-applicable. At 2 mbar, 15 of the 16 remaining objects were model-applicable, whereas at 1 mbar four of the five recorded objects supported stable parameter extraction. For several objects, localized spectral features became more readily identifiable after pressure reduction. However, the changing fraction of model-applicable spectra must be interpreted together with object loss and the changing composition of the recorded subset.
3.3. Comparison of Fitted Spectral Parameters
The primary quantitative comparison used the 5 mbar measurements because all 20 laser-loaded objects were still recorded and 12 yielded model-applicable spectra. This allows the fitted subset to be considered alongside the eight recorded spectra that did not support the model.
At 5 mbar, the mean fitted linewidth parameter was 7.24 ± 2.38 kHz for the 20 reference particles and 27.13 ± 9.07 kHz for the 12 model-applicable laser-loaded objects (mean ± standard deviation; Figure 4a). The mean difference (laser-loaded minus reference) was 19.89 kHz (95% CI: 14.06–25.71 kHz). A two-sided Welch’s two-sample t-test indicated a statistically significant difference between the groups (t = 7.45, df = 11.92, p < 0.001). The ratio of the group means was approximately 3.75. This comparison applies to the model-applicable laser-loaded subset, rather than to all 20 recorded objects.
Figure 4.
Comparison of fitted spectral parameters for aerosol-loaded SiO2 reference particles and model-applicable laser-loaded objects. (a) Effective fitted linewidth at 5 mbar, showing individual observations and group mean ± standard deviation; the bracket reports the ratio of the group means. (b) Fitted frequency at 5 mbar for the same groups. (c) Effective fitted linewidths at 1, 2, 5, and 10 mbar on a continuous linear vertical axis. The model-applicable laser-loaded subsets contain n = 4, 15, 12, and 1 objects, respectively. Laser-loaded means are not connected across pressures because the model-applicable subsets differ between pressure conditions.
The fitted frequency parameter was 41.89 ± 4.25 kHz for the reference group and 36.15 ± 8.72 kHz for the laser-loaded subset (Figure 4b). The larger standard deviation in the latter indicates greater variation between objects.
Two additional substrate controls were examined at 5 mbar. Six of 20 spectra were model-applicable for both the bare-substrate control and the DMSO-treated bare-substrate control, compared with 12 of 20 for the SiO2-coated laser-loaded group and 20 of 20 for the aerosol-loaded SiO2 reference group (Supplementary Figure S4). The model-applicability fraction of the bare-substrate control did not differ significantly from that of the SiO2-coated laser-loaded group (Fisher’s exact test, p = 0.111), but was significantly lower than that of the aerosol-loaded reference group (p < 0.001). The DMSO-treated bare-substrate control likewise did not differ significantly from either the bare-substrate control (p = 1.000) or the SiO2-coated laser-loaded group (p = 0.111), but had a significantly lower model-applicability fraction than the aerosol-loaded reference group (p < 0.001).
Among the model-applicable spectra, the mean fitted linewidth was 31.94 ± 6.40 kHz for the bare-substrate control and 27.80 ± 5.12 kHz for the DMSO-treated bare-substrate control. No statistically significant linewidth difference was detected between the two control groups (Holm-adjusted p = 0.490), between the bare-substrate control and the SiO2-coated laser-loaded group (p = 0.215), or between the DMSO-treated bare-substrate control and the SiO2-coated laser-loaded group (p = 0.845). In contrast, both control groups showed significantly larger fitted linewidths than the aerosol-loaded SiO2 reference group (bare-substrate control, p = 3.17 × 10−4; DMSO-treated bare-substrate control, p = 3.22 × 10−4).
Figure 4c compares the fitted linewidth parameters at all four pressures. Model-applicable laser-loaded spectra were obtained at each pressure, with sample sizes of 4, 15, 12, and 1 at 1, 2, 5, and 10 mbar, respectively. The laser-loaded linewidth parameters were generally higher than the corresponding reference values. Because both object survival and model applicability changed during pressure reduction, the plotted laser-loaded distributions do not represent the pressure dependence of a fixed cohort.
3.4. Substrate Observations After Irradiation
Registered scanning electron microscopy (SEM) was used to compare particulate features in the same substrate regions before and after pulsed irradiation. Sixteen 4 μm × 4 μm ROIs were geometrically defined around four FIB-fabricated cross-shaped fiducial markers, as summarized in Supplementary Figure S2, and Figure 5 shows one representative ROI in detail. The registered images revealed three types of changes: retained features, features that disappeared from their original positions, and newly visible features after irradiation. Energy-dispersive X-ray spectroscopy (EDS) of selected particulate features showed localized enrichment of Si and O relative to the surrounding Al substrate, as illustrated in Supplementary Figure S3. Together, these observations show that pulsed-laser irradiation produced clear changes in the particulate state of the substrate surface.
Figure 5.
SEM observations of the same substrate regions before and after pulsed irradiation. (a) A cross-shaped fiducial marker fabricated by focused ion beam milling and four adjacent regions of interest (ROIs), labeled upper left (UL), upper right (UR), lower left (LL), and lower right (LR). Each ROI is 4 μm × 4 μm. (b) Registered feature positions within one ROI, classified as retained, disappeared, or newly visible. (c,d) SEM images of the same ROI before and after irradiation. Scale bars are 2 μm in panel (a) and 1 μm in panels (b–d).
These measurements characterize changes on the substrate. They do not identify the composition of individual objects captured in the optical trap or establish a correspondence between a specific substrate feature and a measured spectrum.
4. Discussion
The spectral results reveal two differences between the laser-loaded objects and the aerosol-loaded reference particles. First, some successfully confined objects did not produce spectra that supported the current single-mode damped harmonic oscillator model. Second, even among the model-applicable spectra, the response remained different from that of the aerosol-loaded SiO2 reference particles. At 5 mbar, the 12 model-applicable laser-loaded objects had a mean effective fitted linewidth 3.75 times that of the reference group, while their fitted frequencies were also more widely distributed. At 10 mbar, all aerosol-loaded SiO2 reference spectra supported stable parameter extraction, whereas only one of the 20 laser-loaded spectra did so. Strong damping can broaden a resonance and reduce peak prominence; the low model-applicable fraction therefore reflects reduced parameter identifiability under these measurement conditions rather than the absence of damped harmonic oscillator dynamics. The reference result under the same pressure and acquisition conditions nevertheless shows a systematic difference between the two loading groups.
Object loss also increased as the pressure was reduced. Four of the 20 laser-loaded objects were lost before the 2 mbar measurement, and a further 11 of the remaining 16 were lost before 1 mbar. Thus, the lower-pressure measurements were obtained from progressively smaller subsets of the original 20 laser-loaded objects.
The substrate-side SEM and EDS observations show that pulsed-laser irradiation changed the particulate state of the substrate surface. The disappearance of pre-existing features, appearance of newly visible features, and Si/O enrichment at representative structures indicate substantial changes in the particulate material after irradiation. The substrate control experiments further show that pulsed-laser loading from bare Al, with or without DMSO treatment, can also produce trapped objects with broad and heterogeneous spectral responses. At 5 mbar, both control groups had lower model-applicable fractions than the aerosol-loaded SiO2 reference and substantially larger fitted linewidths. Their fitted linewidths were not significantly different from those of the SiO2-coated laser-loaded group, and no significant difference was detected between the untreated and DMSO-treated bare-substrate controls. These results support a contribution from the Al substrate to the spectral differences observed after pulsed-laser loading, while DMSO treatment did not produce an additional detectable change under the present conditions.
The spectral differences cannot, however, be attributed solely to heterogeneity in the released particles. For several laser-loaded objects, the spectral structure changed as the pressure was reduced, indicating that the measured response also depended on the post-capture motional state. Nonlinear motion, orbital dynamics, and particle–gas interactions can modify the shape and width of the measured spectrum [23,34,35]. The broad effective fitted linewidths, dispersed fitted frequencies, and model-inapplicable spectra may therefore reflect contributions from both differences among the trapped objects and differences in their motional states. The present measurements do not quantitatively separate these contributions.
Taken together, these results show that successful confinement alone is not sufficient to establish that a laser-loaded object is suitable for subsequent model-based particle characterization. Some captured objects do not provide spectra that support the current model, while others are analyzable but still differ markedly from the SiO2 reference response. Evaluation of pulsed-laser loading should therefore consider not only capture success, but also the fraction of analyzable spectra and their agreement with the target-particle reference. These measures can provide a practical basis for evaluating future changes in substrate preparation and laser-loading conditions.
5. Conclusions
We compared the spectral responses of 20 objects loaded from the SiO2-coated substrate with those of 20 aerosol-loaded SiO2 reference particles in vacuum optical tweezers. All 80 reference spectra measured over 1–10 mbar supported the selected damped harmonic oscillator model. At 5 mbar, all 20 SiO2-coated laser-loaded objects were recorded, but only 12 yielded model-applicable spectra. Their mean effective fitted linewidth was 27.13 ± 9.07 kHz, compared with 7.24 ± 2.38 kHz for the reference group, giving a ratio of approximately 3.75. The bare-Al and DMSO-treated bare-Al controls each yielded 6 of 20 model-applicable spectra, and their fitted linewidths were not significantly different from that of the SiO2-coated laser-loaded group. SEM and EDS observations further showed irradiation-induced changes in the particulate state of the substrate surface.
Successful capture alone is therefore not sufficient to judge the quality of pulsed-laser loading. Combining model-applicability assessment with comparison to a target-particle reference provides a practical basis for evaluating future substrate-preparation and loading conditions.
Supplementary Materials
The following supporting information can be downloaded at https://www.mdpi.com/article/10.3390/photonics13121101/s1: Figure S1: Mean PSDs of all 20 laser-loaded objects recorded at 5 mbar; Figure S2: Geometric definition of the SEM regions of interest around the four FIB-fabricated cross-shaped fiducial markers; Figure S3: Representative SEM image and EDS elemental maps of a selected particulate feature on the irradiated Al substrate; Figure S4: Comparison of fitted spectral parameters at 5 mbar for the aerosol-loaded SiO2 reference, SiO2-coated laser-loaded, bare-substrate control, and DMSO-treated bare-substrate control groups.
Author Contributions
H.G. and Z.F. conceived the study and designed the experiments. J.J. and H.G. built the optical platform. H.G. and Y.F. processed the experimental data. Y.L., W.L., H.H. and Y.W. contributed to the discussion of the results. H.G. wrote the manuscript. All authors have read and agreed to the published version of the manuscript.
Funding
This work was supported by internal funding from the State Key Laboratory of Ocean Sensing (Grant No. OSZ-2025PY13), the National Natural Science Foundation of China (Grant No. 62505276), the Laboratory of Space Inertial Measurement Technology (Grant No. LabSIMT-2025-05), the Young Elite Scientist Sponsorship Program by CAST (Grant No. YESS20240342), and the Fundamental Research Funds for the Central Universities (Grant No. 226-2025-00079).
Data Availability Statement
All relevant data are available from the corresponding author upon request.
Acknowledgments
The authors gratefully acknowledge Zhejiang Lab for providing the instrumentation used in this study.
Conflicts of Interest
The authors declare no conflicts of interest.
References
- Moore, D.C.; Geraci, A.A. Searching for new physics using optically levitated sensors. Quantum Sci. Technol. 2021, 6, 014008. [Google Scholar] [CrossRef] [Scilit]
- Millen, J.; Monteiro, T.S.; Pettit, R.; Vamivakas, A.N. Optomechanics with levitated particles. Rep. Prog. Phys. 2020, 83, 026401. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Ranjit, G.; Cunningham, M.; Casey, K.; Geraci, A.A. Zeptonewton force sensing with nanospheres in an optical lattice. Phys. Rev. A 2016, 93, 053801. [Google Scholar] [CrossRef] [Scilit]
- Liang, T.; Zhu, S.; He, P.; Chen, Z.; Wang, Y.; Li, C.; Fu, Z.; Gao, X.; Chen, X.; Li, N.; et al. Yoctonewton force detection based on optically levitated oscillator. Fundam. Res. 2023, 3, 57–62. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Zhu, S.; Fu, Z.; Gao, X.; Li, C.; Chen, Z.; Wang, Y.; Chen, X.; Hu, H. Nanoscale electric field sensing using a levitated nano-resonator with net charge. Photonics Res. 2023, 11, 279–289. [Google Scholar] [CrossRef] [Scilit]
- Fu, Z.; Xu, J.; Zhu, S.; He, C.; Zhu, X.; Gao, X.; Cai, H.; He, P.; Chen, Z.; Zhang, Y.; et al. Optically levitated nanoparticles as receiving antennas for low frequency wireless communication. PhotoniX 2025, 6, 1. [Google Scholar] [CrossRef] [Scilit]
- Li, T.; Wu, M.; He, P.; Li, N.; Chen, Z.; Fu, Z.; Gao, X.; Hu, H. Tunable dipole–dipole interactions between nanoparticles levitated by two orthogonally polarized optical traps. Photonics Res. 2024, 12, 2139–2147. [Google Scholar] [CrossRef] [Scilit]
- Shen, K.; Duan, Y.; Ju, P.; Xu, Z.; Chen, X.; Zhang, L.; Ahn, J.; Ni, X.; Li, T. On-chip optical levitation with a metalens in vacuum. Optica 2021, 8, 1359–1362. [Google Scholar] [CrossRef] [Scilit]
- Melo, B.; Cuairan, M.T.; Tomassi, G.F.M.; Meyer, N.; Quidant, R. Vacuum levitation and motion control on chip. Nat. Nanotechnol. 2024, 19, 1270–1276. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Sun, C.; Pi, H.; Kiang, K.S.; Georgescu, T.S.; Ou, J.Y.; Ulbricht, H.; Yan, J. Tunable on-chip optical traps for levitating particles based on single-layer metasurface. Nanophotonics 2024, 13, 2791–2801. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Summers, M.D.; Burnham, D.R.; McGloin, D. Trapping solid aerosols with optical tweezers: A comparison between gas and liquid phase optical traps. Opt. Express 2008, 16, 7739–7747. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Nikkhou, M.; Hu, Y.; Sabin, J.A.; Millen, J. Direct and Clean Loading of Nanoparticles into Optical Traps at Millibar Pressures. Photonics 2021, 8, 458. [Google Scholar] [CrossRef] [Scilit]
- Weisman, E.; Galla, C.K.; Montoya, C.; Alejandro, E.; Lim, J.; Beck, M.; Winstone, G.P.; Grinin, A.; Eom, W.; Geraci, A.A. An apparatus for in-vacuum loading of nanoparticles into an optical trap. Rev. Sci. Instrum. 2022, 93, 115115. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Lindner, S.; Juschitz, P.; Rieser, J.; Fein, Y.Y.; Debiossac, M.; Ciampini, M.A.; Aspelmyer, M.; Kiesel, N. Hollow-core fiber loading of nanoparticles into ultra-high vacuum. Appl. Phys. Lett. 2024, 124, 143501. [Google Scholar] [CrossRef] [Scilit]
- Khorshad, A.A.; Houlihan, R.; Devaney, N. In-vacuum dry launching of silica microparticles using an array of custom MEMS devices. Opt. Express 2025, 33, 7043–7057. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Asenbaum, P.; Kuhn, S.; Nimmrichter, S.; Sezer, U.; Arndt, M. Cavity cooling of free silicon nanoparticles in high vacuum. Nat. Commun. 2013, 4, 2743. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Kuhn, S.; Asenbaum, P.; Kosloff, A.; Sclafani, M.; Stickler, B.A.; Nimmrichter, S.; Hornberger, K.; Cheshnovsky, O.; Patolsky, F.; Arndt, M. Cavity-Assisted Manipulation of Freely Rotating Silicon Nanorods in High Vacuum. Nano Lett. 2015, 15, 5604–5608. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Fu, Z.; She, X.; Li, N.; Hu, H. Launch and capture of a single particle in a pulse-laser-assisted dual-beam fiber-optic trap. Opt. Commun. 2018, 417, 103–109. [Google Scholar] [CrossRef] [Scilit]
- Bykov, D.S.; Mestres, P.; Dania, L.; Schmöger, L.; Northup, T.E. Direct loading of nanoparticles under high vacuum into a Paul trap for levitodynamical experiments. Appl. Phys. Lett. 2019, 115, 034101. [Google Scholar] [CrossRef] [Scilit]
- Troyer, S.; Fechtel, F.; Hummer, L.; Rudolph, H.; Stickler, B.A.; Delić, U.; Arndt, M. Quantum ground-state cooling of two librational modes of a nanorotor. Nat. Phys. 2026, 22, 584–590. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Fu, Z.; Ma, Y.; Li, C.; Jiang, J.; Li, N.; Hu, H. Capture region shrinkage and levitation instability of optical trap induced by decreased damping in vacuum. Opt. Commun. 2022, 512, 128034. [Google Scholar] [CrossRef] [Scilit]
- Hoang, T.M.; Ahn, J.; Bang, J.; Li, T. Electron spin control of optically levitated nanodiamonds in vacuum. Nat. Commun. 2016, 7, 12250. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Millen, J.; Deesuwan, T.; Barker, P.; Anders, J. Nanoscale temperature measurements using non-equilibrium Brownian dynamics of a levitated nanosphere. Nat. Nanotechnol. 2014, 9, 425–429. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Ricci, F.; Cuairan, M.T.; Schell, A.W.; Hebestreit, E.; Rica, R.A.; Meyer, N.; Quidant, R. A Chemical Nanoreactor Based on a Levitated Nanoparticle in Vacuum. ACS Nano 2022, 16, 8677–8683. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Li, C.; Ma, Y.; Wang, J.; Ying, Q.; Zhu, S.; Fu, Z.; Jiang, X.; Yang, H.; Liang, T.; Gao, X.; et al. Morphological Tracking and Tuning of Silica Nanoparticles in Optomechanical Systems for Enhanced Stable Levitation in Vacuum. ACS Appl. Nano Mater. 2024, 7, 25493–25499. [Google Scholar] [CrossRef] [Scilit]
- Ricci, F.; Cuairan, M.T.; Conangla, G.P.; Schell, A.W.; Quidant, R. Accurate Mass Measurement of a Levitated Nanomechanical Resonator for Precision Force-Sensing. Nano Lett. 2019, 19, 6711–6715. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Zheng, Y.; Zhou, L.M.; Dong, Y.; Qiu, C.W.; Chen, X.D.; Guo, G.C.; Sun, F.W. Robust Optical-Levitation-Based Metrology of Nanoparticle’s Position and Mass. Phys. Rev. Lett. 2020, 124, 223603. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Li, C.H.; Jing, J.; Zhou, L.M.; Fu, Z.H.; Gao, X.W.; Li, N.; Chen, X.F.; Hu, H.Z. Fast size estimation of single-levitated nanoparticles in a vacuum optomechanical system. Opt. Lett. 2021, 46, 4614–4617. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Frimmer, M.; Luszcz, K.; Ferreiro, S.; Jain, V.; Hebestreit, E.; Novotny, L. Controlling the net charge on a nanoparticle optically levitated in vacuum. Phys. Rev. A 2017, 95, 061801(R). [Google Scholar] [CrossRef] [Scilit]
- Hempston, D.; Vovrosh, J.; Toroš, M.; Winstone, G.; Rashid, M.; Ulbricht, H. Force sensing with an optically levitated charged nanoparticle. Appl. Phys. Lett. 2017, 111, 133111. [Google Scholar] [CrossRef] [Scilit]
- Hebestreit, E.; Frimmer, M.; Reimann, R.; Dellago, C.; Ricci, F.; Novotny, L. Calibration and energy measurement of optically levitated nanoparticle sensors. Rev. Sci. Instrum. 2018, 89, 033111. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Berg-Sørensen, K.; Flyvbjerg, H. Power spectrum analysis for optical tweezers. Rev. Sci. Instrum. 2004, 75, 594–612. [Google Scholar] [CrossRef] [Scilit]
- Nørrelykke, S.F.; Flyvbjerg, H. Power spectrum analysis with least-squares fitting: Amplitude bias and its elimination, with application to optical tweezers and atomic force microscope cantilevers. Rev. Sci. Instrum. 2010, 81, 075103. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Gieseler, J.; Novotny, L.; Quidant, R. Thermal nonlinearities in a nanomechanical oscillator. Nat. Phys. 2013, 9, 806–810. [Google Scholar] [CrossRef] [Scilit]
- Rashid, M.; Toroš, M.; Setter, A.; Ulbricht, H. Precession Motion in Levitated Optomechanics. Phys. Rev. Lett. 2018, 121, 253601. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Dawson, C.; Bateman, J. Spectral analysis and parameter estimation in levitated optomechanics. J. Opt. Soc. Am. B 2019, 36, 1565–1573. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.




