Skip to Content
  • Review
  • Open Access

23 November 2026

56 Pages

Electrocardiogram Foundation Models: From Representation Learning to Clinical Evidence

,
,
,
,
,
and
1
Information and Computer Science Department, College of Computer Science and Engineering, University of Ha’il, Ha’il 55476, Saudi Arabia
2
Department of Data Science and Artificial Intelligence, College of Computer Science and Engineering, University of Ha’il, Ha’il 55476, Saudi Arabia
3
Information Systems Department, College of Computer and Information Sciences, Prince Sultan University, Riyadh 11586, Saudi Arabia
4
Maternal and Child Health Nursing Department, College of Nursing, University of Ha’il, Ha’il 55476, Saudi Arabia
Math. Comput. Appl.2026, 31(6), 268;https://doi.org/10.3390/mca31060268 
(registering DOI)
This article belongs to the Special Issue Artificial Intelligence, Machine Learning, and Deep Learning: Innovations and Real-World Applications

Abstract

Electrocardiogram (ECG) foundation models promise representations reusable across clinical tasks, but backbone benchmark evidence can be taken to support adapted models or clinical interventions without justification. This critical, non-systematic review examines comparative, generalization and clinical evidence, asking which backbone findings can legitimately support downstream applications. Pretraining improved label efficiency in low-label comparisons, mostly against training from scratch; the one controlled supervised-baseline estimate covered three models and one dataset. Gains over strong supervised baselines were small or absent, and scale did not consistently predict performance across models. Independent evaluations remain few and mostly in-distribution. We did not identify independent locked-model external validation of a clinical use, device-stratified or test–retest evaluations of foundation models, or prospective trials reporting results for clinical use; calibration evidence was limited to one developer-reported summary measure. Trials of conventional artificial intelligence-enabled ECG illustrate how thresholds, workflows and clinician response shape clinical effects. We propose a platform–use evidence framework distinguishing backbone, adapted model and deployed intervention, with seven heuristic, untested evidence-inheritance principles and an illustrative 116-cell matrix covering three backbones and five applications, coded independently by two authors (87.1% pre-adjudication agreement; Cohen’s κ 0.76) with consensus adjudication. We discuss implications for ECG–language models, governance and research priorities.

1. Introduction

The electrocardiogram (ECG) is among the most widely used cardiovascular tests. Over the past decade, deep learning has demonstrated that ECG recordings contain clinically relevant information beyond what conventional interpretation routinely captures. Task-specific networks have reported performance comparable to cardiologists on selected rhythm-classification tasks [1,2], identified left ventricular systolic dysfunction, and predicted atrial fibrillation and mortality from ECGs without overt abnormalities [3,4,5]. These advances have been reviewed extensively [6,7,8]. Several algorithms have subsequently been evaluated in randomized trials, with reported effects on diagnoses, processes of care and, in one trial, mortality [9,10]. However, these advances were largely achieved through separate task-specific development efforts, each requiring its own labelled data, model development and validation.
ECG foundation models aim to change this task-by-task development paradigm. By learning representations from large ECG datasets, with or without labels and sometimes through alignment with clinical reports, these models may support adaptation to multiple clinical tasks with fewer labelled examples and improved generalization across institutions, devices and populations [11,12,13,14]. Whether these anticipated advantages hold under independent evaluation remains an important empirical question. The field has nevertheless advanced rapidly, with models differing substantially in architecture, learning objectives, training data and scale, alongside increasing availability of pretrained models and evaluations conducted outside their developer groups. Recent reviews have catalogued ECG foundation models [15,16,17], classified cardiovascular foundation models according to the independence of their reported evaluations [18], and assessed the translational maturity of artificial intelligence (AI)-enabled ECG (AI-ECG) applications across clinical conditions [19].
Despite these contributions, an important question remains insufficiently addressed: which evidence belongs to which component of a foundation-model system, and under what conditions can that evidence support a downstream clinical application? An ECG foundation-model platform gives rise to at least three distinct objects of evaluation: the pretrained backbone, adapted models developed for specific clinical tasks, and interventions that embed those models within clinical workflows. A backbone benchmark, an external validation of an adapted model and a randomized trial of a clinical intervention provide different forms of evidence and answer different questions. Yet claims about foundation models can move between these levels without an explicit justification for transferring evidence. Backbone performance may be interpreted as evidence of clinical readiness, while clinical trials of conventional task-specific algorithms may be invoked to support foundation-model applications that have not themselves been prospectively evaluated. A related gap between anticipated and demonstrated benefits has been identified for foundation models developed from electronic health records [20].
This Review addresses this gap by examining what evidence obtained for a shared ECG foundation-model backbone can legitimately support claims about its downstream applications, and which properties require evaluation at the level of each adapted model or clinical intervention. We make four contributions. First, we propose a functional definition of an ECG foundation model based on demonstrated reuse rather than pretraining methodology alone, distinguishing model classification from the strength of evidence supporting its reuse (Section 2). Second, we critically synthesize comparative performance, generalization and clinical evidence (Section 3, Section 4 and Section 5). We distinguish findings concerning foundation models from evidence derived from conventional task-specific AI-ECG, identify who conducted each evaluation, assess whether evaluation data originated outside the development setting, and distinguish missing evidence from demonstrated poor performance. Third, we introduce a platform–use evidence framework comprising three objects of evidence, seven proposed heuristic principles governing when evidence might be inherited across them, and an illustrative evidence matrix applied to five worked examples (Section 6). Fourth, we examine emerging ECG–language models, governance challenges associated with shared model platforms, and a prioritized research agenda for clinical translation (Section 7), before concluding in Section 8.
Several terms are used consistently throughout this Review. A backbone is a pretrained model characterized by its training data, learning objective and input specification. An adapted model combines a backbone with an adaptation procedure, task-specific components, target population and, where applicable, a decision threshold. A deployed intervention integrates an adapted model into a clinical workflow. A locked model has its relevant parameters and any applicable decision threshold fixed before evaluation. External validation refers to evaluation using data from outside the development institutions; we additionally distinguish whether the evaluation data were excluded from the pretraining corpus. An evaluation is considered independent when its investigators were not involved in developing the evaluated model and had no identified institutional relationship with its developers. Competing interests are documented separately rather than treated as automatic grounds for exclusion. Conventional AI-ECG refers here to task-specific algorithms not characterized in the evaluated studies as reusable ECG foundation models. Finally, not identified indicates that evidence of a specified kind was not found among the sources examined; it does not establish that such evidence is absent or that the model performs poorly.
This Review is a critical, non-systematic synthesis. Up to 21 October 2026 we ran targeted searches of the web, preprint servers (arXiv, medRxiv), publisher sites, PubMed-derived records and bibliographic databases (Crossref, OpenAlex, DataCite and, where accessible, Europe PMC), supplemented by citation tracking from primary reports and recent reviews [15,16,18,19], and searched two clinical trial registries, ClinicalTrials.gov and ISRCTN, with the queries listed in Supplementary Table S12. The searches were targeted rather than run with one prespecified search string, no protocol was registered, no formal eligibility criteria were applied and screening was not duplicated, so we report no record counts. The sources sought, stated here retrospectively because they were not prespecified, were reports of models presented as ECG foundation models or as reusable pretrained ECG representations; evaluations of such models by their developers or by others; validation studies of AI-enabled ECG relevant to generalization, calibration or reliability; and randomized or prospective evaluations of AI-enabled ECG in clinical care. We examined primary publications wherever accessible and recorded, for each quantitative claim, whether it was checked in a full text, a journal page, an abstract or a secondary report (Supplementary Note 1). A further targeted search on 5 November 2026, made during revision, is reported separately and is not part of the search described above (Supplementary Note 4). Throughout, statements that evidence was “not found”, “not identified” or “not reported” refer only to the sources examined within this search; they do not show that such evidence does not exist. When findings relied only on abstracts, preprints or secondary sources, we identified those limitations explicitly. The proposed framework and evidence-inheritance principles are intended to structure critical appraisal and guide future evaluation; they have not been independently validated and are not presented as established standards. How the evidence matrix was coded, the agreement between its two raters and the adjudication of disagreements are described in Section 6.5 and Supplementary Note 5.

2. What Defines an ECG Foundation Model?

The term foundation model was introduced for models trained on broad data, generally with self-supervision at scale, that can be adapted to a wide range of downstream tasks [11], and in medicine it has been extended to generalist systems that accept several data types [12]. In electrocardiography the label has been applied since 2023 to models that differ in almost every design choice: a convolutional network supervised on more than ten million recordings [13], self-supervised transformers trained on unlabelled waveforms [21,22,23], contrastive models aligned with free-text reports [24,25,26] and instruction-tuned multimodal language models that read ECG images [27]. If the term names a training recipe, it describes how a model was built, not what it can be relied on to do. The clinical and economic case for foundation models rests instead on a functional claim: that one learned representation can be reused across clinically distinct problems with fewer labels and less development effort than building each solution separately. That claim is empirical, and in this literature it has been asserted more often than tested in a form that could refute it, a conclusion also reached for foundation models built on electronic health records [20].

2.1. From Task-Specific Networks to Reusable Representations

Deep learning entered electrocardiography as task-specific models that matched cardiologists in rhythm and abnormality classification [1,2] and recovered information that readers do not extract, such as left ventricular systolic dysfunction, atrial fibrillation from sinus-rhythm recordings, mortality risk and electrocardiographic age [3,4,5,28]. None was a foundation model, but together they established that the surface ECG encodes physiology beyond conventional measurements and that deep networks can recover it. Reuse followed pragmatically. A network trained on 1.6 million ECGs with 68 cardiologist-assigned diagnoses was fine-tuned for rare conditions and outperformed training from scratch [29]. Self-supervised methods from vision and speech were adapted to the ECG [30,31,32], and patient-contrastive representations learned from more than 3.2 million ECGs supported linear models that outperformed networks trained from scratch [31]. These studies predate the label but applied its essential test, whether a representation learned for one purpose supports tasks it was not trained for. What changed after 2023 was scale, breadth of claims and open release [13,14,22,23,33].

2.2. Learning Paradigms and What Each Assumes

Because a pretraining objective decides which information the representation is rewarded for keeping, each embodies an implicit hypothesis about cardiac electrophysiology (Figure 1a). Supervised pretraining on a large label vocabulary, as in ECGFounder (10,771,552 ECGs from 1,818,247 individuals; 150 labels parsed from clinical annotations made with software assistance) [13] or the paediatric ECG-Fyler (93 ECG-finding codes) [34], organizes the representation around cardiologists’ categories. It rewards only information that predicts those labels, and labels recorded through structured menus or with automated interpretation available may inherit the habits of that process [35]; neither possibility has been tested for an ECG foundation model. Masked modelling, as in ST-MEM [21] and HuBERT-ECG [23], assumes that what is needed to fill in a missing segment is clinically informative. The ECG is highly redundant across beats and, approximately, across leads [36], so a reconstruction objective could be satisfied largely by learning periodicity and lead relationships; and information present in a masked representation is not necessarily accessible to a simple classifier: ST-MEM’s area under the receiver operating characteristic curve (AUROC) for PTB-XL superclass diagnosis was 0.838 with a linear head on frozen features and 0.933 after full fine-tuning [21]. Contrastive learning assumes that what related views share is clinically relevant [30,31,37,38], and ECG-FM and DeepECG-SSL combine it with masked objectives [14,22]. We suggest two untested consequences: patient-level positives may teach a representation to discount within-patient change, which serial ECG review exists to detect, and generic augmentations such as amplitude scaling may remove diagnostic information. Latent predictive objectives, contrastive predictive coding and joint-embedding prediction, predict abstract representations rather than raw samples, in principle ignoring unpredictable noise [39,40,41]; in one controlled comparison on a shared backbone, predictive coding gave the most transferable representations [42]. Language alignment pairs ECGs with reports [24,25,26,43] and enables zero-shot use, but a report is derived from the ECG it describes, often with software assistance [35], so alignment may teach a reporting style together with its errors. Across paradigms, what matters is what the objective rewards and treats as nuisance, not whether labels are used, and in the first independent benchmark both supervised and self-supervised designs were among the most consistent models [44].
Figure 1. Learning paradigms, representations and reuse in ECG foundation models. (a) Components of an ECG foundation model and its downstream use. Columns list options, not a fixed pipeline. ECG inputs are what the model receives when it is used; auxiliary data paired with ECGs during pretraining (diagnostic labels, reports, imaging, laboratory or genetic data) are not necessarily required at inference, although ECG–language models may still take text prompts at inference for zero-shot classification; clinical task families are defined by their downstream targets, each listed with the reference standard against which it is typically judged. Each pretraining signal embodies an assumption about which ECG variation is clinically meaningful. Learned representations can contain physiological information and may also contain acquisition and demographic information (orange) that could act as shortcuts; the extent of this is untested for ECG foundation models. Adaptation regimes are grouped by what remains shared after adaptation: representation reuse (identical frozen weights), parameter sharing (small task-specific additions) and initialization transfer (full fine-tuning; weights diverge). Acquisition shift is a robustness dimension that cuts across clinical task families. (b) Proposed distinction between classifying a model and describing the evidence for its reuse (our proposal; not a validated standard). Classification sets a low bar and does not depend on who performed the evaluation. The reuse evidence profile records descriptors of backbone-level evidence rather than assigning a maturity grade. Backbone-level evidence does not establish the readiness of any clinical application.

2.3. What Representations Encode

Three kinds of evidence bear on whether representations encode transferable physiology: correspondence with conventional measurements and imaging phenotypes [22,33,45]; genetic association of representation-derived features [33,45], which is suggestive but not specific, because body habitus is also heritable; and transfer to targets defined outside the ECG, such as echocardiographic function, coronary stenosis on computed tomography (CT) angiography, natriuretic peptide and kidney disease [3,13,34,38,46], which is the strongest because the reference standard does not come from the ECG. All three are correlational. Representations are also likely to encode what is not physiology: age and sex are among the easiest targets [13,28], and acquisition features such as device, filtering and site may be encoded as well. A downstream model could use either as a shortcut. Section 4 examines the evidence on this hypothesis, which we did not find tested directly.

2.4. Adaptation and the Meaning of Reuse

A representation reaches a clinical task through adaptation, and the adaptation regime determines what an evaluation measures (Figure 1a). Linear or shallow probing of a frozen encoder measures how accessible information is; full fine-tuning measures the representation’s value as a starting point; parameter-efficient methods train a small number of added parameters [47]; zero-shot use relies on alignment with text [24,26]; and continued pretraining on target-domain data is a further option [42]. Regimes can rank models differently [42,44], so a claim of reuse is incomplete unless it states the regime. We distinguish three modes by what remains shared after adaptation. Representation reuse means that the same frozen weights serve several tasks; parameter sharing means that downstream models share most backbone weights and add small task-specific parameters; initialization transfer means that pretrained weights start full fine-tuning, after which descendants no longer share identical weights with the backbone or each other. The starting weights need not come from ECGs: a vision transformer initialized from ImageNet weights and fully fine-tuned on ECG-derived images illustrates transferred initialization, not evidence that an ECG representation can be reused across clinical tasks; its metrics come from overlapping one-second windows of one public dataset, are not stated per recording, and lack external validation [48]. Evidence transfer is a separate question: whether results obtained on the backbone can be relied on for an application built from it. We propose, as a hypothesis examined in Section 6, that it is most defensible under representation reuse and weakest under initialization transfer because fine-tuning changes the weights that were tested.

2.5. Scale, Diversity and Label Efficiency

Scale is the most visible property and the most easily mistaken for generality. Pretraining corpora range from about 180,000 to more than ten million ECGs and model sizes from 3.8 to almost 190 million parameters [13,21,23,33,41,44], but the comparative evidence available (Section 3) does not show that larger pretraining corpora or models yield better transfer [23,34,42]. Diversity is a better guide but is usually reported as volume. Many models draw on the same few public resources, including MIMIC-IV-ECG, PTB-XL, CODE-15% and the Chapman and Ningbo collections [21,22,26,44,49,50,51], so evaluation on those datasets is not independent of pretraining for several models. Populations are narrower than record counts suggest: ECGFounder’s data are mostly from US cohorts, regions such as Africa and India are underrepresented, and paediatric data are largely absent outside ECG-Fyler [13,23,34]. Label efficiency is the most direct evidence that a representation is reusable and has been reported consistently [14,21,22,25,31,44], but usually against networks trained from scratch rather than equally tuned supervised models, in-distribution, and often within rhythm classification, where performance is near ceiling.

2.6. Classifying a Model and Describing the Evidence for Its Reuse

Two questions are routinely conflated: what kind of model this is, and how strong the evidence is that its representation can be relied on beyond its training. We propose to answer them separately; the proposals are offered for debate and have not been validated (Figure 1b). For classification, a model is an ECG foundation model when it was pretrained on broad ECG data, alone or with other modalities, for transfer to tasks not fixed at training time, and has been shown to transfer to at least one clinically distinct task beyond its pretraining targets, in data not used for pretraining. For supervised models, tasks that restate the training labels do not count. The bar is deliberately low and does not depend on who performed the evaluation: independence is a property of evidence, not of a model. The one-task criterion is a provisional, low-bar operational choice: transfer to one clinically distinct task does not show general reuse, which the profile below describes. To make the classification reproducible we propose provisional decision rules (Supplementary Table S13), which have not been tested for agreement between assessors. Pretraining data count as broad when they were not selected on any downstream target and come either from more than one source or from an unselected clinical archive; we set no numerical threshold for size because no evidence links a particular number of recordings to reusability. A task is clinically distinct when its target is defined by a different clinical question or reference standard from the pretraining targets: for supervised pretraining, a target that is neither one of the pretraining labels nor a merger or relabelling of them; for self-supervised pretraining, any clinical target, although the same label set in a new dataset tests transfer across populations or acquisition rather than a new task; for language-aligned pretraining, a target whose reference standard lies outside the paired reports, such as echocardiography, a laboratory value or a registry outcome. Data count as unused for pretraining only when their exclusion is documented at patient or source level. Applied to the sources reviewed, ECGFounder qualifies through natriuretic peptide and ejection fraction [13], whereas its evaluation on PTB-XL classes that overlap its training labels would not count; ST-MEM qualifies through diagnostic classification [21]; and a network initialized from ImageNet weights and fine-tuned on ECG-derived images does not because its pretraining data are not ECGs [48]. Borderline cases remain, for example a target that is a clinical composite of pretraining labels, a large single-institution archive restricted to one care setting, or a language-aligned model evaluated on diagnoses that appear in its reports, and two assessors could reasonably classify them differently; the rules require the rationale to be recorded so that disagreement can be identified and resolved.
The strength of a reuse claim is then described by a reuse evidence profile, a set of backbone-level descriptors rather than a grade. Clinical breadth records which task families have been tested and against which reference standards: rhythm and conduction; cardiac structure and function defined by imaging or haemodynamics; prognosis and future events; non-cardiac or systemic phenotypes; and patient characteristics, which are weak evidence because age and sex are easy to predict. Transfer to families whose reference standards lie outside the ECG is more persuasive than transfer within ECG interpretation. Robustness to acquisition shift (single-lead, wearable or image input, manufacturer, sampling rate) is recorded separately because it tests whether a capability survives a change in recording, not a new capability. The remaining descriptors state the mode of reuse and label economy, the separation between pretraining and evaluation data, the comparator, and the evaluator of each piece of evidence. Ye and colleagues tier cardiovascular foundation models by whether their performance has been reported on independent data [18], and Chen and colleagues appraise the translational maturity of AI-ECG applications [19]. The profile addresses a different object, the reusable backbone before any application is considered, and making that level explicit allows the central question of this Review to be asked: which evidence about a shared backbone may be relied on by the applications built from it, and which must be established again for each. Section 6 places the profile at the first level of the platform–use framework.
Applying the profile shows how it separates classification from evidence. ECGFounder’s developers evaluated it on rhythm interpretation, patient characteristics, laboratory and clinical targets including natriuretic peptide and ejection fraction, and single-lead and photoplethysmography inputs, mainly through fine-tuning [13], and independent investigators have since evaluated it across seven task categories, including under frozen evaluation [44]: its profile spans several families, includes robustness evidence and has independent support. ST-MEM’s original report evaluated diagnostic classification on two public datasets and reduced-lead settings [21]; it qualifies as a foundation model because diagnosis lies beyond its reconstruction objective, but its original profile was narrow, and its pretraining and evaluation sources shared provenance, a reflection of the evidence reported at the time rather than a demonstration of poor generality. Three implications follow. A claim that an ECG model is a foundation model should state the task families evaluated and their reference standards, the acquisition shifts tested, the mode of reuse, the separation between pretraining and evaluation data, the comparator and the evaluator; without these the claim describes intent rather than evidence. Because representation reuse, parameter sharing and initialization transfer leave different amounts of the evaluated backbone intact, evidence about the backbone and about each application derived from it must be kept apart. And the evidence that most directly tests reuse, evaluation across distinct families by investigators other than the developers with stated modes of reuse, is recent, comes from few groups and includes preprints.

3. When Do ECG Foundation Models Provide an Advantage?

The question of advantage is conditional. Within one study a pretrained backbone can outperform a network trained from scratch, match a well-tuned supervised model and trail a smaller model with a better inductive bias, depending on the task, the number of labels, the adaptation regime and the protocol [34,44]. Our reading of the comparative evidence is that pretraining gives a reproducible advantage when labelled data are scarce, that the advantage over strong supervised models narrows or disappears as labels become plentiful, and that most published comparisons are not controlled well enough to support claims of general superiority for any model or paradigm. Table 1 summarizes the evidence by condition; study-level extraction is in Supplementary Table S1 and methodological notes on individual comparisons in Supplementary Note 2.
Table 1. Where ECG foundation models have and have not shown an advantage: synthesis of comparative evidence.

3.1. What Makes a Comparison Informative

Apparent advantages can be created or erased by at least eight features of a comparison: the label scope of the task; the population; the input format (sampling rate, segment length, lead set); separation between pretraining and evaluation data; the adaptation and tuning budget; the strength of the comparator; the metric, particularly micro-averaged AUROC dominated by common labels and uncorrected multiple comparisons; and the evaluator, who chooses tasks, baselines and protocols [14,23,41,44]. The supervised DeepECG model, for example, received a Bayesian sweep of 670 runs whose counterpart for the self-supervised model is not described [14], and ECG-JEPA’s comparison mixed retrained baselines, published values and unmatched pretraining budgets [41].
An example shows how these features interact. When ECGFounder was adapted with 100 labelled paediatric examples to detect reduced ejection fraction, its internal AUROC was 0.47 (95% confidence interval [CI] 0.46–0.49), below a network trained from scratch (0.50) and a masked autoencoder pretrained on the same paediatric data (0.63), whereas ECG-Fyler reached 0.80; with 100 adult examples in the same paper ECGFounder reached 0.72 [34]. The paper does not explain the paediatric result or describe whether encoders were frozen or how comparators were tuned. A mismatched adaptation recipe or input handling, instability with 100 examples, or a genuine absence of paediatric information in a representation learned from adults could each explain it, and the first three are at least as plausible as the last. The result shows that one pipeline outperformed another under one protocol, not that one representation is superior, which is true of most comparisons in this literature.

3.2. Comparisons by Investigators Other than the Developers

Four studies compared several published foundation models under one protocol, with evaluators who had not developed the models they assessed (Supplementary Tables S1 and S10). They are the most informative, and least flattering, evidence available. The ICLR 2026 benchmark evaluated eight foundation models and two supervised baselines on 24 result rows in seven task categories, under fine-tuning, frozen evaluation and linear probing [44]. ECGFounder, ECG-JEPA and ECG-CPC were strongest on adult interpretation; ECG-CPC, a 3.8-million-parameter state-space model, ranked first for cardiac structure and function, outcome prediction and most patient-characteristic tasks; and no model significantly exceeded the supervised S4 baseline in acute-care prediction. Differences among strong models were small: on PTB-XL with all labels, the 2.2-million-parameter S4 model trained from scratch (AUROC 0.941) ranked above six of the eight foundation models [44]. The benchmark tested only in-distribution splits, used one fine-tuning recipe for all models, and was run by the developers of ECG-CPC, a competing model in the comparison, an interest that the paper does not discuss. Several of its result rows bundle hundreds of endpoints, so a category ranking says little about any single prediction (Supplementary Note 2). Rankings also shifted with the adaptation regime: ST-MEM did relatively better under linear probing and ECG-CPC relatively worse with a linear head [44].
Two frozen-embedding benchmarks reached different rankings. With lightweight classifiers on frozen embeddings for conduction disturbance and atrial fibrillation in four public datasets, ECGFounder and ECG-FM performed best and remained strong with small training sets, larger HuBERT-ECG versions did not outperform the smallest, and ECG-JEPA, among the strongest after fine-tuning in the ICLR benchmark, was weakest [52]. FOUND-AF likewise ranked frozen ECGFounder first for atrial fibrillation on four single-lead datasets, with F1 between 92.8% and 99.5% [53]. Neither trained a supervised baseline under its own protocol. In the fourth study, of echocardiographically defined structural heart disease in one public dataset, a ResNet trained from scratch (macro AUROC 0.8246) performed on par with a frozen ECG-FM probe after in-domain self-supervised adaptation (0.8233); partial fine-tuning raised ECG-FM to 0.8509, whereas ECGFounder (0.8228) and HuBERT-ECG (0.8182) did not exceed the scratch network [55]. Read together, the identity of the best model depends on regime and task. Frozen representations appear most useful when the downstream task resembles the pretraining signal, as for ECGFounder’s rhythm and conduction labels [52,53], while self-supervised representations may need substantial adaptation before their information becomes accessible, consistent with the linear–fine-tuned gap described in Section 2. That interpretation has not been tested directly.
Together with a fifth comparison identified during revision, these are five studies, not five replications of one result. The 24 result rows of the ICLR benchmark come from one study, one recipe and one group, so its findings on acute-care prediction, on scale and on parity with the supervised S4 model are single-study findings, and several of its rows bundle many endpoints; the frozen-embedding and atrial fibrillation benchmarks address one task family each and trained no supervised baseline under their own protocol, and the structural heart disease study used one public dataset [52,53,55]. The fifth, from a search made during revision and reported separately (Supplementary Note 4), is BenchECG, published in September 2026 [56]. Its authors, who developed one of the compared models (xECG) and declared no competing interests, evaluated the released weights of ST-MEM, ECG-JEPA, ECG-CPC and ECGFounder alongside xECG on eight public datasets and ten tasks, under fine-tuning and linear probing with five runs per task. After fine-tuning, the 2.9-million-parameter ECG-CPC (BenchECG score 0.797) scored close to the transformers ST-MEM and ECG-JEPA (0.793 and 0.783, about 85 million parameters each), whereas ECGFounder, supervised on more than ten million ECGs, scored lowest (0.588), below a supervised xLSTM trained without pretraining (0.769); xECG scored highest (0.838). Differences on short 12-lead tasks were small after fine-tuning (PTB-XL AUROC 0.923 to 0.930) and larger under linear probing, and ranks again changed with the adaptation regime. Because the compared models were pretrained on different corpora, its authors caution that the differences cannot be attributed to architecture or pretraining method alone. Read together, the five comparisons agree that rankings depend on task and adaptation regime and that parameter count does not order performance across different models, but each was run by a group with a competing model or addressed one task family, and the acute-care finding still rests on one benchmark.

3.3. Developer-Reported Comparisons

Developer studies report gains over training from scratch almost uniformly, largest with few labels, and smaller or no gains against strong supervised models. The most tightly paired comparison is DeepECG, in which a self-supervised and a supervised model from the same group were evaluated on internal, external public and external private data [14,57]. Micro-averaged AUROC over 77 conditions was essentially identical: 0.990 versus 0.992 internally, 0.981 versus 0.980 on public external datasets and 0.983 versus 0.983 for the private external health systems. Differences emerged in small tasks, such as long QT syndrome genotype classification (0.931 versus 0.850; p = 0.026), whereas for reduced ejection fraction the published article reports 0.926 (0.923–0.929) versus 0.917 (0.913–0.921) in its Results and Supplementary Table, and 0.928 versus 0.900 in its structured summary, which we could not match to a table [14,57]. The comparison is not fully controlled: the self-supervised model saw about 1.9 million ECGs from several sources and the supervised model about 1.02 million from one institution, with different tuning [14]. The models also ran at different operating points: the self-supervised model had higher sensitivity and lower specificity internally (0.994 and 0.795 against 0.959 and 0.952, micro-averaged) and in every external cohort we extracted, so near-equal AUROC does not imply equal false-positive burden; because the supplement does not state which of two listed thresholds produced these values, the difference cannot be attributed to pretraining [14]. A small low-label advantage is therefore confounded with more, and more diverse, data. The supplement also reports a negative comparison: on the same internal test set, a supervised model trained from random initialization exceeded both fine-tuned models for ejection fraction below 50% (AUROC 0.909 against 0.885 and 0.887) but not for 40% or below (0.864 against 0.917 and 0.926), and how these models were trained is not described [14]. Other developer comparisons show the same pattern: ECGFounder within rounding of a strong supervised model on a Brazilian test set and 2–6 AUROC points above weaker comparators after fine-tuning on new tasks [13]; ECG-FM’s advantage concentrated at small and intermediate training sizes and disappearing as data grew, its developers cautioning that pretraining “may not provide significant value downstream given sufficiently large task-specific datasets” [22]; and HuBERT-ECG’s smallest version outperforming its larger ones on some tasks [23]. The developers of DeepECG and ECG-CLIP also benchmarked ECGFounder, ECG-FM or DeepECG and reported advantages for their own models, under label mappings and adaptation they chose [14,25]. Language-aligned models report the largest relative gains in low-label and zero-shot settings, but zero-shot AUROCs averaged across datasets of 75–79% [24,26] remain well below supervised performance; their value is in requiring no labels.

3.4. Label Efficiency: The Clearest Advantage

Label efficiency is the most consistently reported advantage of pretraining, across paradigms and evaluators [14,22,29,31,34,44]. The only controlled estimate against a supervised baseline fine-tuned ECGFounder, ECG-JEPA and ECG-CPC on subsets of EchoNext for 11 echocardiographic findings and compared them with the S4 baseline trained on the same subsets [44]; its authors were not involved in developing ECGFounder or ECG-JEPA, but they developed ECG-CPC and the S4 baseline, so for ECG-CPC the estimate is a developer estimate. For 250 to 1000 training examples, a foundation model needed 0.30–0.62 times as many labelled examples as S4 for ECGFounder, 0.11–0.42 for ECG-JEPA and 0.21–0.40 for ECG-CPC to reach the same error; the 3.3- to 9-fold gains stated in the abstract correspond to the inverses of the smallest ratio for each model (1/0.30 ≈ 3.3 for ECGFounder, 1/0.21 ≈ 4.8 for ECG-CPC and 1/0.11 ≈ 9 for ECG-JEPA). These estimates hold for three models (ECGFounder, ECG-JEPA and ECG-CPC), one single-centre dataset (EchoNext), one endpoint set (11 echocardiographic findings, summarized as macro AUROC), one fine-tuning recipe applied to all models, one supervised comparator (S4), training sizes of 250 to 1000 examples and in-distribution testing. They show what was achievable under those conditions; they are not an estimate of the label efficiency of ECG foundation models in general, of these models on other targets, populations or adaptation regimes, against other tuned supervised models, or at larger training sizes, and the derivation of the 3.3- to 9-fold figures is ours because the paper does not show it (Supplementary Note 2). The developers of a contrastive ECG–text model report that it needed on average 90.8% less training data to match the best comparator (abstract read) [25].
The pattern suggests a mechanism. With few labels the task data cannot constrain the model, and pretraining supplies the prior that determines what is learned; as labels increase, the prior matters less. The largest gains have been reported for rare conditions, for example carcinoid heart disease (AUROC 0.772 versus 0.492 for the comparator) [29], for long QT genotypes [14] and for very small fine-tuning sets in a new population [34], whereas gains at full label volume are small [14,22,34]. This interpretation predicts that foundation models should matter most for rare diseases, new phenotypes, small institutions and populations underrepresented in labelled data. Two cautions apply. Low-label results are the most sensitive to the adaptation recipe and the most uncertain, and the comparator is usually a model trained from scratch on the same subset, which is the relevant comparison for a new task but not for an established task with a mature, supervised model.

3.5. Transfer Across Clinical Task Families

The advantage is not uniform across task families (Table 1). For rhythm and conduction interpretation, performance is near ceiling for all strong models, and differences between foundation and supervised models are typically below 0.01 AUROC [13,14,44]; frozen representations transfer well [52,53], and any advantage is unlikely to be clinically material, although robustness and calibration may still differ. For cardiac structure and function, AUROCs for reduced systolic function cluster around 0.92–0.93 in developer evaluations [14,22,54], with differences of about 0.01–0.03 where supervised comparators exist [14,54], and multi-label structural disease reached a macro-averaged AUROC of about 0.85 with average precision below 0.3 for valvular endpoints [55]. Evidence for outcomes is thinner and mostly from single datasets, with a small state-space model performing best in the independent benchmark [44] and developer-reported comparisons that are not reproducible across groups [23]; with ten positive labels a contrastive ECG–text model reported small margins over its best comparator, for example AUROC 0.910 versus 0.884 for acute myocardial infarction (abstract read) [25]. For acute-care prediction, no foundation model significantly exceeded a small supervised model [44]. Paediatric results suggest that population match matters [23,34,44]. Patient-characteristic tasks are easy for all models and weak evidence of clinical capability, and transfer to targets defined by other modalities is possible but variable: a fine-tuned model for coronary stenosis on CT angiography had external AUROCs from 0.667 to 0.971 across four vessels [46].

3.6. What Explains the Differences

In the comparisons available, scale did not predict performance across different models, but these comparisons are few: the controlled scaling study comes from the group that ran the ICLR benchmark [42,44], the comparison of HuBERT-ECG sizes from its developers and one independent benchmark [23,52], and in BenchECG a 2.9-million-parameter state-space model scored close to 85-million-parameter transformers after fine-tuning [56]. Within one architecture the picture differs: in its developers’ ablation, pretraining xECG on a smaller corpus lowered its BenchECG score from 0.820 to 0.802 [56], consistent with a benefit of more pretraining data when the architecture is held fixed. No investigators independent of all the models compared have varied scale systematically. In the ICLR benchmark the best model overall had 3.8 million parameters, and models with 87–97 million parameters spanned almost the whole range of performance [44]; larger HuBERT-ECG versions did not consistently outperform smaller ones [23,52]; and in a controlled study of five objectives on one state-space backbone at data scales up to about 11 million ECGs, pretraining loss followed a power law with data but lower loss did not translate consistently into downstream gains [42]. Three explanations are plausible, none established: inductive bias, with architectures that model long-range temporal structure suiting the ECG at current scales [42,44]; match between pretraining and target populations, illustrated by paediatric transfer and by gains from in-domain adaptation [34,42,55]; and match between the pretraining signal and the task [52,53]. That differences reflect protocols more than models cannot be excluded for any single comparison.

3.7. What the Comparative Evidence Supports

Pretraining confers a consistently reported advantage in label efficiency over training from scratch, largest with small training sets, quantified against a supervised baseline in one controlled experiment, independent for two of its three models [44]. Against strong supervised models with abundant labels, foundation models achieve parity or small gains in rhythm and conduction interpretation and modest, inconsistently replicated gains elsewhere [13,14,44,54]. In the few comparisons available, scale has not been a reliable predictor across different models, and architecture, data match and adaptation appear to explain more of the variation [42,44,55], although more pretraining data improved one architecture in its developers’ ablation [56]. The evidence does not support claims that any foundation model is universally superior, or that rankings from one study transfer to another [44,52,53,55]; that pretraining helps acute-care prediction has been tested in one benchmark only, in which no foundation model significantly exceeded the supervised baseline, so the question is open rather than settled [44]. Shared held-out evaluation sets that no developer can pretrain on, equally tuned comparators, per-label metrics with confidence intervals and calibration, and explicit overlap audits would make future comparisons informative; Section 6 turns these into evidence requirements.

4. Generalization, Robustness and Reliability

Broad pretraining on diverse data is expected to yield representations that transport better than those learned for one task at one site. That expectation is a hypothesis, and this section asks how much of the evidence tests it: whether reported performance is reproduced with new patients, institutions, recording conditions, calendar periods and repeated measurements of the same person. Two features of the evidence shape what follows. Most studies of external validity, subgroup performance and test–retest reliability in AI-enabled electrocardiography concern task-specific networks; we use them as context and mark them as such. And we report two attributes separately for every study because they are easily conflated: who performed the evaluation (developers, their collaborators or other investigators) and whether the evaluation data were externally sourced, outside the developers’ institutions and, separately, outside the pretraining corpus. In the evaluations by other investigators that we could read, performance was estimated within each dataset or on in-distribution splits [44,52,53,55]. The exception, identified during revision, is BenchECG, in which models fine-tuned on a Brazilian primary-care dataset were applied unchanged to datasets from the USA, Germany and China for age estimation and to a US intensive-care cohort for mortality prediction [56]; these test transport across populations for threshold-free regression and ranking tasks, without calibration or a declared clinical use. We did not find an independent evaluation of a locked system; a fixed classifier and threshold applied to a new site that contributed to neither pretraining nor fine-tuning. That statement is limited to a non-systematic review of published work. Study-level details are in Supplementary Table S2 and Supplementary Note 3.

4.1. What a Validation Design Can and Cannot Show

Table 2 sets out what each validation design can establish. Two distinctions recur. First, every downstream result is produced by a backbone, an adaptation procedure, a head, a threshold and a reference standard. External validation of a fine-tuned classifier tests the whole system and cannot locate a failure in any one component, and analysis of frozen embeddings says something about the backbone but nothing about whether a clinical application built on it will transport. Second, discrimination, calibration and reliability are separate properties. AUROC depends only on the ranking of predictions and is insensitive to prevalence, so a model can keep its AUROC in a new setting while its probabilities, sensitivity at the threshold and positive predictive value change substantially.
Table 2. What each validation design can and cannot show about an ECG foundation model, and the foundation-model evidence found.

4.2. Data Separation and Leakage

Leakage makes internal and external results look alike, and there are four routes for foundation models. The first is record-level leakage, because a patient contributes many similar ECGs; PTB-XL’s released folds respect patient assignment [49,66], and a biometric preprint reporting re-identification of individuals across institutions illustrates how strong the individual signature is [67]. Reports of how splits were made are uneven: the published ECGFounder article does not state how its development–test split was made, and its patient counts differ from those in its preprint (Supplementary Note 3), and ECG-Fyler excluded test patients from pretraining but does not describe patient-level splitting within fine-tuning [13,34]. The second route is specific to foundation models: overlap between the pretraining corpus and evaluation data, which patient-level splitting within the fine-tuning set cannot prevent. Several datasets in the largest independent benchmark were in some models’ pretraining corpora, with no overlap audit [44]; a MIMIC-IV partition served as an external test for DeepECG while another partition of the same source contributed to pretraining; the partitions were separated by patient, so the test patients were unseen but the source was not [14]; and ECG-FM’s task with machine-read labels used MIMIC-IV-ECG, also a pretraining source [22]. A dataset external to a developer’s hospital may therefore not be external to the pretraining corpus, and “unseen” can be claimed only when the corpus is documented. The third route is the reference standard. Labels derived from machine interpretation or from reports written by clinicians who saw the tracing are legitimate for pretraining but problematic for evaluation because agreement with a reading is not agreement with the patient’s condition [13,14,58]; ECG-Fyler restricted pretraining to ECG-finding codes to avoid leakage into an echocardiographic target [34], and in a task-specific image model all 120 reviewed high-confidence false positives were reported to be label errors [68].
The fourth route is shortcut learning of acquisition or institutional features. In an independent frozen-embedding benchmark, ECG-JEPA embeddings separated source datasets almost perfectly (adjusted Rand index 0.98 for conduction disturbance and 1.00 for atrial fibrillation) while separating diagnoses poorly (0.07 and 0.00), whereas ECGFounder showed the reverse pattern (dataset 0.03 and 0.12; label 0.24 and 0.70) [52]. Yet ECG-JEPA ranked among the best models after full fine-tuning in another benchmark [44]. These are representation-level observations. Dataset separability shows that frozen embeddings carry information correlated with the source, which may reflect device, filtering, population or labelling conventions as well as features a model could use as shortcuts; it does not show that an adapted model uses that information, that its predictions are wrong, or that patients would be harmed. Fine-tuning changes the representation, and a head trained on a frozen encoder can down-weight directions correlated with the source, so the geometry of the pretrained embedding need not predict the behaviour of the adapted model, as ECG-JEPA’s fine-tuned performance shows [44]. A claim of robustness failure would need evidence at each further step: that the adapted model’s predictions depend on acquisition features, that this dependence lowers performance at a new site, and that the loss changes clinical decisions. We therefore treat embedding geometry as a reason to test (principles P2 and P4), not as evidence of downstream or clinical failure. Informative designs include probing the adapted model’s own penultimate features for the source dataset; evaluation sets in which source and diagnosis are deliberately decorrelated; matched perturbations of the same recordings (resampling, filtering, simulated lead placement) with the change in output measured; and recordings of the same patients on different devices.
Three attributes of an evaluation should be reported separately because each can hold without the others: institutional externality (data from outside the developers’ institutions), pretraining disjointness (data outside the pretraining corpus at patient and source level) and evaluator independence (Supplementary Table S7). As a minimum for future studies we propose (Supplementary Table S15) that reports state: the pretraining corpus by dataset, version, institutions, calendar period and patient count; for every evaluation dataset, whether its source, patients or recordings entered pretraining, adaptation or threshold selection, and how this was checked (identifier matching where identifiers exist, otherwise detection of near-duplicate signals); patient-level partitioning of adaptation data, with all of a patient’s recordings in one partition; the calendar periods of development and evaluation data, so that temporal separation can be judged; the origin of labels and reference standards in both phases, including whether evaluation labels derive from machine interpretation or from readers who saw the tracing; which data were used to select hyperparameters, checkpoints and thresholds; and the evaluators’ relationship to the developers. Where a pretraining corpus cannot be released, a list of hashed record or patient identifiers, or an overlap audit run by the developers on request, would let others check disjointness. These items correspond to requirements B1, A2, A3 and A4 to A6 of the evidence matrix (Section 6); they are our proposal, not an existing standard.

4.3. External Validation

Figure 2 shows reported discrimination at internal testing and at temporal or external validation for the foundation-model-based studies that report both, with task-specific studies for context; rows differ in endpoint, metric, adaptation and cohort and are not comparable. For interpretation of 77 conditions, DeepECG’s self-supervised and supervised models lost about 0.01 or less of micro-averaged AUROC between internal and external data (Section 3), with per-condition thresholds set on the development validation split and applied unchanged [14]. The private external datasets came from centres whose investigators are co-authors, so the data were externally sourced, but the evaluation was not independent, and the micro-average is dominated by common labels. This is the strongest evidence that an ECG interpretation model can transport, and the only study we found that compared transport against a matched supervised model; for interpretation, pretraining did not transport better, whereas for reduced ejection fraction and incident atrial fibrillation the self-supervised model’s small advantage was reported to persist at external sites, with values given only in supplementary tables [14].
For other tasks, losses were larger and more varied. A single-lead hyperkalaemia model initialized from ECGFounder and fine-tuned on lead I had an AUROC of 0.936 (95% CI 0.914–0.958) on internal test patients, 0.858 (0.844–0.872) on a later period at the development hospital and 0.808 (0.788–0.826) at another hospital with a prespecified frozen threshold [59]. The external cohort was recorded on a different equipment mix, the authors include ECGFounder’s senior author, and the preprint reports no prevalence, calibration, device analysis or model trained without pretraining, so the loss cannot be attributed to any one factor. A model fine-tuned from a foundation model to predict coronary stenosis on CT angiography had internal AUROCs of 0.744–0.818 for four vessels and external AUROCs of 0.667–0.971 [46], and a pretrained left ventricular dysfunction model kept its discrimination between two hospitals but fell from 0.945 to 0.910 in follow-up pairs [58]. ECG-FM’s evaluation on its developers’ institutional cohort used data excluded from pretraining but adapted on that institution’s training split [22], which is adaptation to a new cohort rather than validation of a locked model. A developer study of one backbone reported that parameter-efficient adaptation generalized better than full fine-tuning, especially out of domain [61,62], direct evidence that out-of-distribution behaviour depends on the adaptation procedure as well as the backbone. A contrastive ECG–text model was evaluated on MIMIC-IV with five-fold cross-validation, which is adaptation to a new dataset rather than validation of a locked model (abstract read) [25].
The task-specific literature shows the same pattern. A low-ejection-fraction algorithm kept an AUROC of 0.92 (0.91–0.93) at four US sites in 13,960 patients [65], an emergency biomarker model met prespecified non-inferiority criteria [69], and a survival model’s C-index fell from 0.775 internally to 0.638–0.773 externally [70]: tasks with a well-defined structural reference standard keep their discrimination, whereas prognostic tasks lose more. This is an observation across heterogeneous studies. The external validation of the ejection-fraction algorithm, for example, was performed by investigators from the developing institution, other sites and the manufacturer [65], so independent sites are not the same as independent evaluators. For foundation models the two attributes separate clearly: evaluators other than the developers mostly used externally sourced public data without testing transport between sites; the exception tested transport of age and mortality models across populations [56], whereas transport of clinical classifiers at a threshold was tested only by the groups that built the models [14,22,46,58,59].
Figure 2. Reported discrimination at internal testing and at temporal or external validation in foundation-model-based studies that report both, with task-specific models for context. Panel (a) shows the area under the receiver operating characteristic curve (AUROC); panel (b) shows a C-index, a different measure, on its own axis. This is not a comparison between rows: endpoint, metric, development and adaptation procedure, threshold and validation cohort differ and are listed beside each row and in Supplementary Table S2. Each segment joins values reported within one study, and whiskers show 95% confidence intervals where extracted: single-lead hyperkalaemia detection with a model initialized from ECGFounder [59]; ECG interpretation (micro-averaged AUROC) by the self-supervised and supervised DeepECG models, with diamonds showing external public and private datasets [14]; left ventricular systolic dysfunction with a pretrained model, in the baseline analysis and in follow-up pairs before adjustment with earlier echocardiographic results [58]; coronary CT angiography with a fine-tuned ECG foundation model, four vessels [46]; and, in panel b, all-cause mortality with the AIRE survival model (C-index, not comparable with AUROC), diamonds showing the range across external cohorts [70]. All comparisons were performed by the groups that developed the models or their collaborators, and none is an independent external validation. A difference in AUROC does not identify its cause, and a small loss of discrimination does not show that pretraining conferred robustness, because a matched supervised comparator was reported only for DeepECG.

4.4. Population and Demographic Transportability

Demographic evidence for foundation models is limited. A foundation model for left ventricular systolic dysfunction fine-tuned under sex-skewed, race-skewed and balanced scenarios gave AUROCs of 0.85–0.90 or higher across groups in its test cohort and 0.82–0.92 in an external cohort [60], consistent with an earlier task-specific network that kept AUROCs of 0.93–0.96 across five racial and ethnic groups even though race was itself predictable from the ECG [71]. The study appears to be by the model’s developers, has no model trained without pretraining for comparison, and reports no calibration or subgroup thresholds. DeepECG reported true-positive-rate differences below 0.1 and false-positive-rate differences below 0.02 across age and sex groups at its operating thresholds (below 0.01 in its preprint), micro-averaged across conditions, which does not bound the disparity for any single condition [14,57]; a difference of 0.1 in sensitivity would be clinically large. ECG-FM and ECGFounder report no performance by sex, age or race in their main texts, and ECGFounder’s authors note that most of its data come from US cohorts [13,22]. Parity of AUROC does not imply parity of sensitivity or predictive value at a pooled threshold, reference standards may themselves differ across groups, and equal performance within one health system says little about another country, which is the shift that matters for a model intended for reuse.

4.5. Acquisition Shift

Lead reduction produces graded, task-dependent losses: for ST-MEM on PTB-XL, AUROC was 0.933 with 12 leads, 0.903 with six limb leads, 0.856 with lead II and 0.804 with lead I [21], whereas rhythm tasks are reported to survive single-lead input [13,23,53], as physiology predicts. The ECGFounder text we read describes no systematic lead-dropout, sampling-rate or noise-robustness experiment [13]. Among the studies reviewed, we found no foundation-model study that stratified performance by device or manufacturer, although device information is often available, as in PTB-XL’s 11 device types at 51 sites [49], and ECG-FM’s authors state that fine-tuning on reduced lead sets was not explored [22]. For printed or photographed ECGs, the evidence is again task-specific: an image-based model kept an average AUROC of 0.97 in an external German cohort [68], and agreement of image-based structural models with their original scores fell for real-world captures [64]. Because most evaluation datasets are public and acquired with a few device families in a few countries, the apparent diversity of external datasets understates the sameness of their acquisition, and robustness to acquisition shift reflects adaptation choices such as lead augmentation as well as pretraining.

4.6. Temporal Stability and Test–Retest Reliability

Temporal validation is rare. In the hyperkalaemia study the temporal set excluded development patients, and the subsequent external step was partly confounded with a later calendar period and different equipment [59]. ECG-FM split its institutional cohort by patient and time to simulate prospective use [22]. Other foundation-model studies report no temporal evaluation that we could identify, and random internal splits from the same period are optimistic estimates of performance on future patients.
Test–retest reliability, whether a model gives the same output for the same patient when nothing has changed, is a precondition for serial monitoring and threshold-based decisions. The only study we found concerns task-specific models from the developing group: across 1,118,263 pairs of ECGs one to thirty days apart, an ensemble for structural heart disease had a concordance correlation of 0.89–0.92 against 0.79–0.88 for individual networks, and instability was more likely in younger patients and inpatients [64]. The interval was long enough for genuine clinical change, the other sites belonged to the same health system, the abstract’s statement of readiness for implementation sits uneasily with the authors’ advice against use in acute care, and the study did not report how often classifications flipped [64]. It did show that reliability differs by setting and age and that averaging several outputs improves it. We identified no test–retest study of a foundation model. The design would test a hypothesis from Section 2, that patient-level contrastive or reconstruction objectives change how much within-patient variation passes into outputs, using repeat ECGs minutes to hours apart, embedding-level and output agreement, and a matched supervised comparator.

4.7. Calibration and Threshold Transport

One foundation-model study assessed calibration, with a weighted Brier score that was lower with self-supervised pretraining by 0.013 on two external datasets and 0.006 on a third, equal on one and higher on the internal test set (0.078 against 0.072), with mixed changes by diagnostic category; a summary score is not a calibration curve and does not show calibration at a target prevalence [14]. In the other foundation-model studies we reviewed, calibration was not reported or could not be confirmed from the text available [13,22,34,52,53,55,58,59]; analyses may exist in material we did not see. The design is feasible: investigators independent of its developers applied a released task-specific structural heart disease model, unchanged, to 45,878 MIMIC-IV patients, with composite AUROC 0.790 (0.786–0.794) against 0.820 on its benchmark test set, a near-calibrated composite (slope 0.93) and overestimated component probabilities that a prevalence shift requiring no local outcome data largely corrected [72]. This is conventional-model context, not evidence about a foundation model. What the literature does show is that thresholds and prevalence move performance even when discrimination is preserved. For a pretrained left ventricular model, specificity at a threshold set at the development hospital fell from 0.852 to 0.763 at the external hospital while AUROC fell by only 0.035 [58]. In the four-site validation of a task-specific algorithm, an AUROC of 0.92 corresponded at a prevalence of 7.9% to a positive predictive value of 30.5% (28.8–32.1%) and a negative predictive value of 98.4%, so about two of every three positive results were false [65]. A fall of nearly nine points in specificity is a clinically large increase in false alarms, and the discrimination metric alone would not reveal it. The independent structural heart disease benchmark likewise found macro AUROCs near 0.85 but areas under the precision–recall curve of only about 0.26–0.28 for aortic and mitral endpoints [55]. Heads fine-tuned with class-weighted or resampled losses are not calibrated to the target prevalence by construction, which we have not seen examined for ECG foundation models, and a foundation model reused across sites by changing only a threshold would need calibration reported at each site.

4.8. What the Generalization Evidence Supports

Discrimination of well-defined interpretation tasks transported with little loss in the one study that tested it against a matched supervised model, which transported equally well [14]; this shows that the task is learnable across settings, not that pretraining makes it so. Losses were larger for single-lead, laboratory-defined, cross-modal and prognostic targets [46,59,70], and whether pretraining reduces them has been examined only in one developer ablation, in which pretraining raised performance in new populations for age and mortality prediction but did not narrow the drop from the training population (C-index falling by 0.108 with pretraining against 0.024 without; age error rising by 1.49 against 0.92 years, the latter our arithmetic from the published supplementary tables) [56]. The designs that would establish robustness at the level of the backbone were not found: independent locked external validation of a clinical use at a declared threshold, test–retest analysis, device-stratified analysis, independent lead-dropout or noise experiments and calibration at the target prevalence. These are absences in a non-systematic review, not evidence of poor robustness. And embedding analyses raise a question that downstream metrics cannot answer [52]. An evidence requirement for reuse at a new site therefore needs documented separation from the pretraining corpus, patient-level splits, evaluation by investigators other than the developers at an institution that contributed to neither pretraining nor adaptation, subgroup performance at the operating threshold, calibration at the target prevalence and a statement of output variation between repeated recordings. Section 6 considers which of these can be inherited.
Why are calibration, device-stratified analysis and test–retest reliability so rarely reported? We can document the gap but not its causes because no study we read asked developers, and the explanations that follow are plausible rather than established. Comparative benchmarks reward discrimination: the multi-model comparisons we read rank models by discrimination measures such as AUROC, F1 or the C-index [44,52,53,55,56], and in those we could verify calibration was not reported, one explicitly leaving it to clinical validation [52,53,55,56]. Calibration is not defined for a backbone, only for an adapted model at a target prevalence, and adapted models re-trained or re-thresholded at each site acquire new calibration each time (principle P5), so backbone papers have no natural calibration target. Device-stratified analysis needs device, manufacturer and filter metadata that public datasets may not provide in usable form, PTB-XL being an exception [49]. Test–retest analysis needs repeated recordings in a period when physiology is clinically unchanged, which is hard to define and rarely released, and in the one large study the interval of up to 30 days allowed genuine change [64]. And most foundation models are research prototypes without a declared clinical use, whereas the evidence a device needs is usually generated later by whoever deploys it. The implication for deployment is that these are properties of each adapted model and site, not of the backbone: a backbone reused across sites creates many operating points, each of which needs calibration at its prevalence, monitoring of drift and alert rates after deployment, and evidence that outputs are stable across devices and repeat recordings. Regulatory review attaches to devices with a defined intended use [73,74], and whether a particular submission needs calibration, device-stratified or repeatability evidence depends on that device and its use; we do not infer specific regulatory requirements from the documents cited. What the framework adds is that backbone evidence cannot substitute for these properties, and that post-market monitoring organized per device would need to be linked across devices that share a backbone (Section 7.2).

5. From Prediction to Clinical Utility: What AI-ECG Trials Teach

Section 3 and Section 4 asked whether pretraining improves discrimination and whether discrimination transports. This section asks whether a better or more portable prediction changes what clinicians do and whether patients benefit. Among the sources examined, we found no completed or reported randomized trial, prospective clinical evaluation or implementation study in which the intervention was an ECG foundation model. A search of ClinicalTrials.gov and ISRCTN on 21 October 2026 identified registered trials that are relevant but not yet informative, in three groups (Table 3; Supplementary Table S12). Only one may evaluate a foundation model directly: a randomized trial, not yet recruiting, of a smartwatch with an unspecified “pre-trained foundation model” in patients after myocardial infarction [75]. Two ongoing randomized trials deploy conventional or unspecified algorithms through a platform built by the developers of an ECG foundation model, with a structural heart disease risk score, EchoNext [76], whose weights are frozen for the trial in one [77] and an unspecified combination of algorithms in the other [78]. A further randomized trial tests a general-purpose multimodal language model for prehospital ECG interpretation [79]. None has reported results, and other registries were not searched.
Table 3. Clinical evidence for AI-enabled ECG by study design (conventional task-specific algorithms; no reported study tests an ECG foundation model).
The clinical evidence therefore concerns conventional, task-specific algorithms. We use it for two purposes that we keep apart: to report what trials observed about the chain of events that follows when an AI-ECG output enters care, and, in the last part of the section, to propose what those observations imply for foundation models. A trial result belongs to a specific algorithm, threshold and workflow, and none of the benefits below is evidence that a foundation model would produce the same benefit. Table 3 summarizes the evidence by design, Figure 3 shows the reported effect estimates, and Supplementary Table S3 gives full extraction. The evidence comes from few groups, and in most trials the evaluating group developed the algorithm it tested. EAGLE, BEAGLE, the DULCE liver-disease trial and their secondary analyses come from Mayo Clinic investigators, several of whom declare patents on or licensing of the EAGLE algorithm [9,83,86,87,91]; four randomized trials come from overlapping author groups in Taiwan; in the three whose disclosures we read the algorithm was developed at the authors’ institution, licensed to the same company in two [10,85], with no competing interests declared in the third [80], and we did not read the disclosure forms of the fourth [84].
Figure 3. Reported effect estimates of conventional AI-ECG interventions on primary and key secondary endpoints in randomized trials. Points are odds ratios, hazard ratios or incidence rate ratios with 95% confidence intervals as published, on a logarithmic axis; they are not pooled and not comparable between rows because effect measures, endpoints, populations and settings differ. For detection and process endpoints a ratio above 1 means more diagnoses or treatment; for mortality endpoints a ratio below 1 means fewer deaths. Marker shape shows the effect measure (circle, odds ratio; square, hazard ratio; triangle, incidence rate ratio), colour shows the endpoint class, and the right-hand column gives each trial’s design, as in Table 3. Open symbols are subgroups defined by the algorithm’s own output. Rows come from EAGLE [9], an inpatient trial of low ejection fraction detection [80], an obstetric screening trial using AI-ECG and an AI stethoscope [81], TRICORDER [82], DULCE [83], an AI-ECG potassium alert trial [85] and an AI-ECG mortality alert trial [10]. * EAGLE: The 95% CI is 1.08–1.61 in the trial report’s Results section (shown in the figure) and 1.01–1.61 in its abstract (see Table 3, note). Detection and process endpoints are surrogate measures. No row concerns a foundation model, and in most trials the evaluating group developed the algorithm.

5.1. What These Trials Tested

A trial of an AI-ECG tests a package: an algorithm, a threshold, a way of delivering the result, a population, a clinical pathway and the response of the clinicians who receive it. In EAGLE the positivity threshold was set so that about 6% of ECGs were positive, and the electronic record recommended considering an echocardiogram, supplemented by an email alert [9,87]. In the mortality-alert trial the threshold was the 95th percentile of the risk score [10]. Thresholds are design decisions that fix the alert burden before any patient is seen. Endpoints form a hierarchy, from diagnostic yield through process (testing, treatment within a time window, door-to-balloon time) to patient outcome, and a positive result at one level does not imply one at the next. A systematic review of 31 randomized trials of AI in cardiovascular care found that 22 reported a significant primary benefit, mostly on intermediate measures, that seven were at low risk of bias, and that the pooled effect of AI-enhanced electrocardiography on heart failure detection was not significant (risk ratio 1.22, 95% CI 0.70–2.14; I2 90%) [92]; a smaller review of 11 trials reported a similar mix of process and clinical benefits [93].

5.2. Detection and Diagnostic Yield

EAGLE cluster-randomized 120 primary care teams (358 clinicians) at the Mayo Clinic, with 22,641 adults without prior heart failure, for access to AI-ECG results or usual care [9]. A new diagnosis of ejection fraction of 50% or less within 90 days occurred in 2.1% of the intervention group and 1.6% of controls (odds ratio 1.32, 95% CI 1.08–1.61, p = 0.007, by mixed-effects logistic regression with care team as a random effect, in the Results text and Supplementary Table S6 of the trial report; its abstract gives 1.01–1.61, and no correction has been published), and in 19.5% against 14.5% of patients with a positive AI-ECG (odds ratio 1.43, 1.08–1.91) [9]. The absolute difference is about one additional diagnosis per 200 patients (our arithmetic). Among AI-positive patients, echocardiography was ordered in 49.6% against 38.1%, with no difference overall (19.2% against 18.2%) [9]. According to the cost-effectiveness analysis based on the trial data, an ejection fraction of 40% or less was found in 22.1% of tested AI-positive patients in the intervention arm and 22.7% in the control arm [91]. The additional diagnoses therefore came mainly from testing more AI-positive patients at a similar yield per test, not from sharper selection. A pragmatic trial of 13,631 inpatients cared for by non-cardiologists in Taiwan, randomized individually, gave a different pattern: new low ejection fraction within 30 days in 1.5% against 1.1% (hazard ratio 1.50, 1.11–2.03), unchanged echocardiography use (17.1% against 17.3%), and among AI-identified high-risk patients a higher proportion of echocardiograms that found low ejection fraction (34.2% against 20.2%) [80]. That pattern is more consistent with reallocating a fixed number of tests towards patients with higher probability, although the two trials differ in setting, window and cut-off.
In an obstetric population in Nigeria (1232 women randomized), left ventricular systolic dysfunction was found in 4.1% against 2.0% with an AI digital stethoscope (odds ratio 2.12, 1.05–4.27) and in 3.4% against 2.0% with a 12-lead AI-ECG (1.75, 0.85–3.62), with no serious adverse events attributed to participation [81]. The TRICORDER cluster trial in 205 UK practices, using an AI stethoscope with a single-lead ECG for three conditions, found no difference in newly coded heart failure (incidence rate ratio 0.94, 0.86–1.02) [82]. The DULCE cluster trial used the ECG to find undiagnosed advanced chronic liver disease in 15,596 primary care patients of 98 teams: new diagnoses within 180 days occurred in 1.0% against 0.5% (odds ratio 2.09, 1.22–3.55) [83]. It matters for this Review because it uses the ECG as a vehicle for non-cardiac disease, the kind of reuse foundation models are meant to support. BEAGLE was a prospective non-randomized study in which 1003 participants with stroke risk factors wore an ambulatory monitor: atrial fibrillation was found in 7.6% of those classified as high risk by AI-ECG and 1.6% of those classified as low risk (odds ratio 4.98, 2.11–11.75), and detection was higher than in propensity-matched usual-care patients in the high-risk group (10.6% against 3.6%) [86]. The first comparison shows risk enrichment, and the second is observational. In a post hoc analysis of the VITAL-AF screening trial, the screening effect was concentrated in the top risk decile of a combined clinical and ECG model, with an interval that reaches zero (2.32 per 100 person-years, 0.01–4.63) [89].
Across the eight randomized trials, primary results were mixed: favourable in EAGLE, the inpatient trial, the mortality-alert trial, ARISE (a process time) and DULCE, and in the stethoscope but not the 12-lead arm of the Nigerian trial, and null for the potassium trial and TRICORDER [9,10,80,81,82,83,84,85]. In one favourable result an interval limit lies within 0.01 of no effect [10]. The two null trials enrolled broad, unselected populations [82,85]. We cannot judge publication or reporting bias from a non-systematic review.

5.3. Clinician Response

The effect of an alert depends on a step that the algorithm does not control. In a secondary analysis of 165 intervention-arm clinicians in EAGLE, those in the top quartile of adoption ordered an echocardiogram after 78.7% (100 of 127) of AI-positive ECGs and the others after 43.0% (243 of 565); low ejection fraction was found in 43 of 100 and 92 of 243 of these echocardiograms, and the adjusted odds ratio for detection was 1.62 (1.21–2.17) [87]. These counts agree with the trial report (692 AI-positive ECGs, 343 echocardiograms and 135 diagnoses), and the reasons for not ordering were not captured. A post hoc analysis of DULCE found the same dependence for liver disease: engagement across 110 clinicians was 29.8%, and diagnostic yield was 10.6% among highly engaged clinicians against 2.9% for others [88]. Process effects in other trials follow the same logic. In ARISE, an open-label trial in 43,234 eligible patients at an academic and a community hospital sharing one catheterization laboratory, with allocation by the date of the first ECG, AI-assisted triage shortened median door-to-balloon time in the emergency department from 96.0 to 82.0 min among 145 angiographically confirmed cases, with a reported positive predictive value of 89.5% [84]. In the potassium-alert trial, in which 70 emergency physicians were randomized, treatment within three hours did not differ overall (hyperkalaemia 8.0% against 7.7%; hazard ratio 1.05, 0.94–1.17) but was more frequent among patients the AI-ECG flagged as hyperkalaemic (69.1% against 41.6%; 2.23, 1.44–3.46) [85]. The alert changed behaviour where it was positive, and that group was a small part of those screened.

5.4. Thresholds, Predictive Values and Net Benefit

A 14.5% rate of new diagnoses among AI-positive patients in EAGLE’s control arm, whose clinicians never saw the result, shows that usual care already identified a substantial fraction of the patients the algorithm flagged [9]. In the intervention arm, 135 of 343 echocardiograms after an AI-positive ECG found low ejection fraction (39%, our arithmetic from the adoption analysis), and about four in five tested AI-positive patients did not have an ejection fraction of 40% or less [87,91]. Positive predictive value depends on prevalence and threshold, so a figure such as 89.5% for ST-elevation myocardial infarction in ARISE cannot be transferred to another setting [84]. No trial we read reported a decision-curve or net-benefit analysis. The cost-effectiveness analysis of EAGLE, a model rather than a trial outcome, gave $27,858 per quality-adjusted life-year over a lifetime horizon, with an incremental gain of 0.0139 QALYs and a probability of 79.5% of being cost-effective at $100,000 per QALY, under assumptions that include lifetime benefit from treatment after diagnosis; its authors declare licensing and patent interests [91]. It shows that a modest increase in diagnoses can be economically attractive if the assumed treatment benefit is real, not that the benefit occurred.

5.5. Patient Outcomes, Harms and Equity

Among the trials we reviewed, the only one with all-cause mortality as its primary endpoint, of an AI-ECG alert in 15,965 hospitalized patients under 39 physicians, reported 90-day mortality of 3.6% against 4.3% (hazard ratio 0.83, 0.70–0.99), with the effect concentrated, in a prespecified analysis, in patients with a high-risk ECG (0.69, 0.53–0.90) and a hazard ratio for cardiac death in that subgroup of 0.07 (0.01–0.56) [10]. The upper bound of the primary interval is 0.99, the subgroup is defined by the algorithm that generated the alert, the cardiac-death estimate rests on small counts, and the authors state that mechanisms are not established and extended analyses were not adjusted for multiplicity [10]. The result has not been replicated. In ARISE, secondary outcomes were mixed and uncorrected for multiplicity: cardiac death 85 against 116 (odds ratio 0.73, p = 0.029) but all-cause mortality 1153 against 1127 (1.02, p = 0.568) [84]. Safety reporting was thin: beyond the Nigerian trial’s statement on serious adverse events [81], we found no systematic report of false-positive burden, downstream testing, incidental findings or overdiagnosis. Equity was rarely reported: the EAGLE and DULCE populations were 94% and 96% White [9,83], the Nigerian and UK trials add diversity [81,82], and we found no treatment effects reported by race, ethnicity or socioeconomic group.

5.6. Why Retrospective Gains May Not Translate into Benefit

Benefit requires a chain: the algorithm must identify the condition, the threshold must give a manageable alert volume and predictive value, the alert must reach the right clinician in time, the clinician must act, confirmatory testing must find the condition, effective treatment must follow and outcomes must improve by more than the harms of false alarms and overdiagnosis. Retrospective discrimination addresses the first link. The trials show attrition at later ones: low adopters did not order the recommended test for more than half of positive results [87,88], none of three trials of low ejection fraction reported treatment after diagnosis in the sources we read [9,80,81], and the one mortality benefit has an unexplained route [10]. Usual care already finds many of the patients an algorithm flags, algorithm-defined subgroups show larger effects by construction, early detection can include cases that would never have caused harm, and effects vary with setting [9,80,81,92].
These observations are the empirical basis of principle P6 (Section 6), and the trials show where the chain broke or weakened. The 12-lead arm of the Nigerian trial did not significantly increase detection (odds ratio 1.75, 0.85–3.62) while the stethoscope arm did [81]; TRICORDER, combining three algorithms in one device, did not increase coded heart failure overall (incidence rate ratio 0.94, 0.86–1.02) [82]; the potassium alert did not change treatment within three hours overall, although it did among flagged patients [85]; and a meta-analysis found the pooled effect of AI-enhanced ECG on heart-failure detection imprecise and not significant (risk ratio 1.22, 0.70–2.14; I2 90%) [92]. Where effects were found they were small in absolute terms, about one additional diagnosis per 200 patients in EAGLE [9], they depended on clinician response [87,88], and about four in five tested AI-positive patients in EAGLE did not have an ejection fraction of 40% or less, a measure of the confirmatory testing each true diagnosis required [87,91]. They illustrate that discrimination alone does not determine utility. None of these trials tested a foundation model, so they show which links can break, not how often they would break for a foundation-model intervention.

5.7. Implications for Foundation Models

The observations above are established for the conventional algorithms tested; the implications that follow are our proposals and have not been tested. A foundation-model-based classifier that replaces the algorithm in a trial is a different intervention even if its AUROC is the same, and none of the effect estimates above is evidence for its effectiveness. A trial can show that a question, endpoint and pathway are worth addressing and how a model serving them should be evaluated; Section 6 sets out when trial evidence could support a presumption, not a proof, for a successor (principle P7). Several lessons transfer as design principles (Supplementary Table S4): endpoints should be placed on the hierarchy and process gains not described as patient benefit; threshold, alert rate, positive predictive value, response rate and yield per confirmatory test should be reported; subgroups defined by the model’s own output should be labelled exploratory; and clinician response should be measured, because a better backbone cannot act on a step it does not control. Two questions are specific to foundation models. A platform that produces many outputs from one ECG multiplies alerts and false positives; TRICORDER, which combined three algorithms in one device and did not increase heart failure detection overall, is a conventional example [82], and whether a shared representation reduces or increases alert burden is untested. And foundation-model reuse typically involves local fine-tuning, which creates a new intervention with a new threshold and calibration, whereas every trial here used a fixed algorithm, as does the registered HEART-AI trial, whose registration states that model weights remain frozen [77]. Label efficiency could matter most where no trial exists because labelled data are scarce, such as rare structural disease, paediatric cardiology and non-cardiac targets of the kind studied in DULCE [83]; that is a hypothesis about development, not clinical evidence.
How much weight should this evidence carry when foundation-model interventions are considered? Its strengths are randomization, pragmatic settings and, in several trials, large samples. Its limitations are that most trials were run by the groups that developed and, in several cases, licensed the algorithm [9,10,83,84,85]; most primary endpoints are diagnostic or process measures, and the one mortality effect has an upper confidence limit of 0.99 and has not been replicated [10]; absolute effects are small; primary results were mixed across the eight randomized trials; most trials were conducted within one or two health systems in the USA or Taiwan, with two elsewhere [81,82]; and effects depended on workflow and clinician response [87,88]. We suggest that it be used in three ways and not in a fourth: it transfers as design lessons, such as placing endpoints on the hierarchy, reporting threshold and alert rate and measuring clinician response (Supplementary Table S4); as an indication of which clinical questions and pathways merit evaluation; and as the incumbent against which a successor must be compared (principle P7). It does not transfer as an effect estimate: none of the odds or hazard ratios above applies to a foundation-model intervention, and even a successor meeting the bridging conditions of P7 obtains only a presumption to be tested in its own trial.

6. The Platform–Use Evidence Framework

Section 2, Section 3, Section 4 and Section 5 examined evidence about different things: whether a representation is reusable, whether it outperforms alternatives, whether performance transports and whether acting on a prediction helps patients. These questions concern different objects, a pretrained backbone, a model adapted for a task and an intervention deployed in a pathway, and the literature tends to move between them without saying so. A benchmark of a backbone is cited for a clinical application, and a trial of one algorithm for deploying another. This section proposes a framework that makes those moves explicit and asks a question specific to foundation models: which evidence can legitimately be reused across the many applications derived from one backbone, and which must be produced again for each. It has three parts: three objects of evidence, seven principles that state when evidence about one object may be relied on for another, and an evidence matrix applied to five worked examples. The framework is an original, testable proposal: each principle states the finding that would falsify it (Table 4). The principles are heuristics. They were derived by reasoning from the structure of foundation-model reuse and from the evidence reviewed in Section 2, Section 3, Section 4 and Section 5, not by mathematical deduction (except the information bound on which P2 rests) or by empirical validation, and their purpose is to make evaluators state the scope within which a piece of evidence is claimed to hold, not to replace task-specific evidence. None is an established standard or a regulatory requirement, and we know of no empirical test of any of them.
Table 4. Seven proposed inheritance principles: what might transfer, under which conditions, what cannot be inferred, what must still be validated, and what would falsify each principle.

6.1. Three Objects, Three Kinds of Claim

The three objects are defined in Section 1 and shown in Figure 4; for appraisal, an adapted model also includes the reference standard and data used for adaptation and its intended input form, and an intervention includes output delivery, pathway, setting, prevalence and the response of the people who receive it. The claim about a backbone is that its representation is reusable and robust; about an adapted model, that it discriminates, transports and is calibrated in a stated population at a stated threshold; and about an intervention, that its use in a stated workflow changes diagnoses, processes or outcomes with acceptable harm. Evidence belongs to the object that was tested, and a claim about one object that rests on evidence about another needs an argument.
Figure 4. The platform–use evidence framework. One backbone supports many adapted models, and each adapted model supports its own deployed interventions. A backbone is the pretrained weights with the data, objective and input specification that produced them; an adapted model adds an adaptation procedure, head, threshold, reference standard and target population; a deployed intervention adds delivery, workflow, setting and clinician response. Lower panels give the question each level answers, the kinds of evidence that answer it with what we found for ECG foundation models, and what the level cannot show. Arrows mark where evidence might be inherited under our proposed principles: P1 identity, P2 ceiling and not floor, and P3 support governing inheritance from backbone to adapted model; P4 asymmetry states that a defect found in a backbone should trigger assessment of every model built on it, without assuming that it is present or absent in each, whereas success in one use is not evidence for another; P5 states that re-adaptation creates a new object; P6 states that evidence of performance is not evidence of utility; and P7 allows a presumptive bridge from a trial of a conventional algorithm only if the successor replaces it and matches its mediators. The principles are our proposals and have not been validated.

6.2. How the Framework Differs from Existing Ones

Established frameworks describe stages of evidence for one technology applied to one purpose: Fryback and Thornbury’s hierarchy of diagnostic efficacy, in which each level is necessary but not sufficient for the next [95]; the V3 framework of verification, analytical validation and clinical validation [96]; and reporting guidelines for studies of single models or interventions [97,98,99,100,101]. Ye and colleagues assign each cardiovascular foundation model a tier according to whether its performance has been reported on independent data [18], and Chen and colleagues appraise AI-ECG applications on five translational criteria [19]; the unit of the first is the model as a whole and of the second the clinical application. REAL-FM, proposed by some of us for biomedical imaging foundation models, rates a model on 17 criteria in five dimensions (data, technical readiness, clinical value, workflow integration and responsible AI), scored by two reviewers with reported agreement [102]; its unit is also the model, and its dimensions say what kinds of evidence a model needs. None of these, as we read them, asks what happens when the first stage is shared by many purposes. The three objects here say instead which object a piece of evidence is about, so the approaches can be combined: each REAL-FM dimension can be assessed separately for a backbone, each adapted model and each intervention. The platform–use framework extends them in three ways (Table 5). Its unit of appraisal is an object together with its derivation chain, so evidence is assigned to a backbone or to a named use built on it. It states, for each move between objects, what might transfer, under which conditions, what cannot be inferred, what must be validated again and what would falsify the principle (Table 4). And it records evidence in states that separate the depth of our verification from the existence of evidence, and both from declared inapplicability. A tier or a maturity rating can be read as a summary of some matrix cells for one object; the framework complements both and has not been externally validated.
Table 5. How the platform–use framework relates to existing frameworks for evaluating diagnostic technologies and clinical AI.

6.3. What Each Level Can and Cannot Show

At the backbone level we found five kinds of evidence: documentation of the pretraining corpus, breadth of reuse across task families, label efficiency against a supervised comparator, evaluation by investigators other than the developers, and analysis of the representation (Section 2, Section 3 and Section 4). Breadth has support from developers and from other groups for some backbones [13,22,44,55], but label efficiency has one controlled external estimate [44]; separation from evaluation data is rarely documented; and no interventional test of reliance on acquisition features has been verified (a candidate preprint for two backbones, identified during the second coding, could not be read in full; Section 6.5). Backbone evidence cannot show the accuracy, robustness, calibration or safety of any particular use, even when the weights are frozen. At the level of the adapted model, evidence concerns a specific combination of backbone, adaptation, head and threshold. The hyperkalaemia model’s internal, temporal and external AUROCs (Section 4) describe that model and not ECGFounder [59], and the dependence of out-of-domain behaviour on the adaptation procedure [61] means that one backbone adapted in two ways gives two objects. Most of what would show a model ready for use is uncertain at this level: locked external validation by others, calibration at the intended prevalence, subgroup and device performance at the threshold, and test–retest reliability. At the level of the intervention, no foundation-model trial has reported (Section 5), and the conventional trials show how much of an effect depends on clinician response, a step that nothing at the first two levels predicts [87,88].

6.4. When May Evidence Move Between Levels? Seven Proposed Principles

Evidence must first be admissible: obtained on data separate from the pretraining and adaptation data, against a reference standard not derived from the same reading process, with the evaluator and data source recorded. The seven principles concern admissible evidence, and Table 4 gives for each what might transfer, the conditions required, what cannot be inferred, what must still be validated and the finding that would falsify it.
The first, identity, states that evidence about a component carries only to objects that contain the same component: most readily underrepresentation reuse, partly under parameter sharing and least under initialization transfer (Section 2). The gradient is a hypothesis; the sources show that adaptation matters [61], not how much of a backbone’s properties persist. Even in the strongest case, identity licenses only properties of the component measured under matching input conditions. A frozen encoder carries its failure modes into an adapted model, but robustness, calibration, safety and clinical validity in a new population, institution or acquisition setting depend on the head, threshold and data and must be tested in the adapted model.
The second, ceiling and not floor, concerns what backbone evidence can bound. For a frozen encoder every head is a function of the embedding and, in principle, cannot add information about the target that the embedding lacks. In practice absence can be shown only relative to the probes and data tried, so a negative probing result is an estimated ceiling, not a proven one, whereas evidence that information is present shows only that it exists. The gap between linear and fine-tuned performance in ST-MEM (Section 2) shows that information can be present without being accessible to a simple head, although added capacity could also explain it [21], and the bound weakens once the encoder is updated. Embedding geometry is an imperfect warning, as the contrast between ECG-JEPA’s dataset-dominated embeddings and its fine-tuned performance shows (Section 4) [44,52].
The bound can be stated precisely. Let X be the ECG, Y a clinical target and Z = f(X) the output of a frozen encoder. Because Y, X and Z form a Markov chain Y → X → Z, the data processing inequality gives I(Y; Z) ≤ I(Y; X); no head applied to Z can recover more information about Y than Z contains, and the lowest achievable error of any classifier that sees only Z is at least that of one that sees X. Information is lost wherever f maps ECGs that differ in a diagnostically relevant way to the same or nearly the same embedding: through pooling over time or leads, a finite embedding dimension, quantization in tokenized objectives, or invariances rewarded during pretraining, for example, to amplitude scaling, baseline drift or variation between beats. A small-amplitude feature, such as a subtle ST-segment or T-wave change, is vulnerable when the pretraining objective treats variation of that size as noise because nothing rewards keeping it, and dimensional collapse, in which embeddings occupy a low-dimensional subspace, has the same effect for directions outside it. Two cases must be kept apart. Information may be absent from Z, in which case no head can recover it, and only changing f, by fine-tuning or retraining, can; or it may be present but not accessible to a restricted head, in which case a more flexible head can recover it. Probing separates these only partly because a high probe accuracy shows presence, whereas a low one is consistent with either, and ST-MEM’s gap between linear probing and fine-tuning [21] is consistent with either because fine-tuning changes f as well as adding capacity. Full fine-tuning escapes the bound because it changes f, which is why the bound applies only to frozen-encoder uses. We know of no study showing that a specific pathology, such as silent myocardial infarction or a microvolt-level repolarization abnormality, is lost in an existing ECG foundation model. Whether it is could be tested by probing frozen embeddings with heads of increasing capacity against targets with external reference standards, with fine-tuned and from-scratch models as comparators.
The third, support, states that evidence is silent, not negative, outside the conditions in which it was obtained: populations, devices, sampling rates, lead sets, calendar periods, label definitions and reference standards. ECGFounder’s unexplained below-chance paediatric result alongside a better adult result in the same study (Section 3) [34] illustrates why support must be stated for each use.
The fourth, asymmetry, proposes as a precautionary decision rule, not an empirical claim, that a defect found in a shared component be treated as possibly present in every model that contains it until tested, whereas success in one use is not evidence for another because a shared encoder shares its failure modes while success depends on the match between task and population. A demonstrated defect therefore triggers a risk assessment of each descendant, not an inference that each fails: adaptation might remove, preserve or amplify it, and propagation has not been demonstrated for any ECG foundation model; dataset clustering is a candidate defect [52]. The principle implies that surveillance of a platform must follow a defect across every derived model (Section 7).
The fifth states that re-adaptation creates a new object; a model re-trained or re-thresholded at a new site is different, and evidence about the original does not carry to it. Evidence can nevertheless attach to a procedure, a pre-specified adaptation protocol with a local acceptance test, if the protocol has been shown across sites to yield acceptable models and the test to detect unacceptable ones. For electronic health record foundation models, continued pretraining on local data at a second hospital and on MIMIC-IV improved label efficiency and sample efficiency [94]; it is non-ECG evidence read at abstract level and cited as an example of the design, which we did not find for any ECG model.
The sixth, performance is not utility, states that evidence of discrimination, transport or calibration does not license a claim of benefit. Quantities from the adapted model, such as alert rate, positive predictive value and agreement with an incumbent, are inputs from which deployed behaviour can be forecast and tested in a silent evaluation [99,103], not substitutes for evidence that clinicians act and patients benefit.
The seventh, mediator-matched bridging, concerns evidence passing from a trial of a conventional algorithm to a foundation-model-based successor that replaces it. The effect of an alert depends on whom it flags, how often, with what predictive value and in what workflow, and matched AUROC matches none of these (Section 5) [87,88]. A bridge therefore requires the same intended use and endpoints, a head-to-head comparison on the local reference standard, agreement of outputs and flagged patients at the same alert rate, calibration at the target prevalence, and a planned and measured response step. It gives a presumption ranked below a trial of the successor, and it does not apply when the successor adds outputs or when the trial’s effect depended on a mediator that was not measured. A conventional trial is context and a lesson in evaluation for its successor, not evidence that the successor will produce the same benefit.

6.5. The Evidence Matrix

The matrix (Figure 5; grid in Supplementary Table S5) lists 26 evidence requirements, seven for the backbone, twelve for the adapted model and seven for the intervention, each with an operational definition and clinical justification (Supplementary Table S8). It applies them to three backbones (ECGFounder, ECG-FM and DeepECG-SSL) and five uses built on them. A cell is verified (V) when evidence meeting the definition is reported and we checked it in the full text of the primary report (p marks a preprint); unverified (U) when such evidence appears to exist but we read only an abstract or a secondary report, values conflict between versions or sections, or a required design element is not confirmed; not identified (N) when we found no evidence of the kind; and not applicable (X) when the declared intended use excludes the condition the requirement tests (eligibility rules in Supplementary Table S6). A cell records whether evidence of a kind exists, not whether it is sufficient. N is not evidence that a model lacks the property or that no study exists anywhere; it marks the limit of a non-systematic search. X is a property of a declared intended use and is never assigned because evidence is missing; we declared standard 12-lead input for three uses and so marked input-form equivalence not applicable there, and prompt sensitivity is not applicable to backbones without text input.
Figure 5. Evidence matrix for three ECG foundation-model backbones and five worked uses. Columns are objects: three backbones (level 1) and five adapted models, each linked to its backbone in the column subtitle (levels 2 and 3). Rows are evidence requirements, defined in Supplementary Table S8. Filled cells are verified in the full text of the primary report (V); hatched cells are identified but not sufficiently verified (U); white cells are not identified in our search (N), which is not evidence of absence; grey cells marked with × indicate evidence requirements that are not applicable to the declared intended use (X). Letters give the evaluator, classified for each model–evaluation pair (D, developers, which for an adapted model is the group that built it, including groups independent of the backbone’s developers; C, collaborating sites; I, independent of the evaluated model’s developers; I?, independence uncertain, assigned per pair in Supplementary Table S10 and not shown in a cell already established by independent evaluations), and p marks evidence that rests on a preprint. An orange dot marks that conventional task-specific evidence for the same clinical target exists, as context and not as evidence about the model. Cells are not graded. Consensus codes after independent coding by two authors and adjudication of disagreements (Section 6.5; both raters’ original codes in Supplementary Data 2), applied to a non-systematic literature search; Supplementary Table S11 gives notes and sources for each cell. Sources: ECGFounder [13]; ECG-FM [22]; DeepECG-SSL [14,57]; external evaluations [44,52,53,55]; single-lead hyperkalaemia [59]; conventional context [9,64,65,80,81,85,87,88,91].
The requirements were chosen by asking, for each object, which claim it supports (Section 6.1) and which evidence designs from Section 2, Section 3, Section 4 and Section 5 and from established reporting and appraisal frameworks [95,96,97,98,99,100,101,103] test that claim. The seven backbone requirements test reusability, separation from evaluation data, label efficiency, evaluation by others and reliance on non-physiological features; the twelve adapted-model requirements follow the validation designs of Table 2 (comparator, separation, locked external, temporal, operating point, calibration, subgroup, device, repeatability and input form); and the seven intervention requirements follow the endpoint hierarchy of Section 5. The set is not exhaustive, omitting for example usability, software verification and cybersecurity, and it has not been validated as complete or weighted; its scope is the evidence needed to answer the inheritance questions this Review asks. Only two requirements may be coded not applicable, B7 when a backbone takes no text input and A12 when a use declares a single input form (Supplementary Table S8), so the declared intended use can change at most eight of the 116 cells through applicability. In an exploratory sensitivity analysis that re-applies the coding rules to the consensus codes (Supplementary Note 4 and Table S14), which tests the matrix’s dependence on our choices rather than validating the framework, removing every applicability exclusion turns six cells from X into N and adds no identified evidence, and restricting both single-lead uses to one input form turns one not-identified and one unverified cell into X; none of the patterns reported below changes. The declared population matters more than the X rule: extending the two adult-declared uses to children would turn their comparator cells (A1), verified for one use and unverified for the other, into N for the paediatric stratum, because evidence is silent outside its support (principle P3).
Each identified cell records the evaluator, classified separately for each model–evaluation pair (Supplementary Tables S7 and S10). An evaluation is coded independent when no author was involved in developing the evaluated model and no institutional relationship or collaboration with its developers was identified; competing scientific or financial interests are recorded and disclosed but are not by themselves disqualifying, and independence that cannot be established is coded uncertain. For an adapted model, the evaluated model is the adapted model, so a group that built it is coded as its developer even when the group is independent of the backbone’s developers; we call such evidence backbone-independent. Evaluation on data external to the developers is not evaluation by independent investigators. Under this rule the four external studies are independent of the developers of the models they evaluated, with two disclosures: the authors of the largest benchmark developed a competing model and baseline in the same comparison [44], and none of the four texts we read contains a competing-interests statement [44,52,53,55]. One model–evaluation pair, in which some authors hold appointments at institutions shared with co-authors of the evaluated backbone, is coded uncertain [55]. Developers of competing models also evaluated ECGFounder, ECG-FM and DeepECG-SSL as comparators; we code these pairs independent, or uncertain where institutions may overlap, with the competing interest recorded [14,25].
One author (M.A.M.) coded all 116 cells, with generative-AI assistance in extracting candidate evidence, and reviewed every cell against the sources (Supplementary Note 1). A second author (R.Q.), who had not taken part in that coding, then coded all 116 cells from the coding guide, the declared uses and the primary sources without access to the first codes, reviewing and confirming AI-assisted extraction drafts. The plan in Supplementary Data 1, with 26 training cells excluded and raters outside the author team, was not followed: there was no joint training, and all cells were analysed. Before adjudication the raters agreed on the state of 101 of 116 cells (87.1%; Cohen’s κ 0.76; Gwet’s AC1 0.84), and on 77 of the 90 cells the plan would have analysed (85.6%; κ 0.73; AC1 0.82) (Supplementary Note 5 and Table S16). Because most codes were N (78 and 70 of the two raters’ 116), κ depends strongly on the marginal distributions, so AC1 is also given; agreement was lowest for adapted-model cells (80.0%; κ 0.66). They agreed on 18 of 21 backbone, 48 of 60 adapted-model and all 35 intervention cells; 13 of the 15 disagreements lay between U and either V or N, two between N and V, and none involved X. Where both raters coded the same cell V or U, they gave the same evaluator code in 14 of 25 cells. We report no confidence intervals because the cells are clustered within eight objects and 26 requirements, too few clusters for reliable resampling; omitting one object at a time gave κ from 0.73 to 0.80. The 15 state disagreements were referred to a third author (S.Z.M.A.), who reviewed and approved adjudication proposals drafted with AI assistance from records containing both raters’ codes; therefore, the third review was not a blinded independent assessment. M.A.M. confirmed the original 116-cell coding, R.Q. confirmed his independent second coding and review of the AI-assisted extraction drafts, and S.Z.M.A. confirmed his review and approval of the 15 adjudication decisions. All authors approved the final consensus classifications and 11 disputed evaluator-code decisions on 6 November 2026 (Supplementary Note 5 and Table S17). Consensus changed 11 states, four from V to U and seven from N to U, and six evaluator codes. These statistics describe the reproducibility of coding by two authors working from the same guide and sources; they do not show that the codes are correct and do not validate the framework or its principles.
As descriptive tallies of the consensus codes for three backbones and five selected uses, not estimates for ECG foundation models generally or scores, of 21 backbone cells, 11 are verified, five unverified, two not identified and three not applicable. Of 95 cells for adapted models and interventions, 10 are verified, 13 unverified, 69 not identified and three not applicable. All 23 identified use-level cells lie at the adapted-model level, and all 35 intervention cells are not identified. All 23 rest on the groups that built the adapted model, nine of them with collaborating sites; six come from groups independent of the backbone’s developers, and none from evaluators independent of the adapted model’s developers. Locked external validation is verified for two uses, by developers with collaborating sites, and unverified for one; the comparison with a supervised model is verified for one use and unverified for two; operating-point performance at the declared threshold is unverified for three uses and verified for none; calibration and subgroup performance are each unverified for one use, reported by developers only as a summary score and as pooled bounds; and test–retest reliability and device analysis are not identified for any use. At the backbone level, a candidate interventional test of acquisition features for ECGFounder and ECG-FM, a preprint reporting noise- and artefact-robustness experiments, is identified but unverified: only its abstract could be read, and whether it changes acquisition features with physiology held fixed, as the definition requires, is not confirmed (Supplementary Table S11).

6.6. Five Worked Examples

The uses were chosen because each has a documented chain from backbone to adapted model, and together they test different principles (Supplementary Table S9). Atrial fibrillation detection on frozen ECGFounder embeddings is the closest to representation reuse and so the strongest case for the identity principle; its evidence comes from investigators independent of the backbone’s developers, who built the adapted pipeline, and is confined to within-dataset evaluation on four single-lead datasets, with a classifier fitted separately for each dataset and cross-validation grouped by recording rather than by patient, and without cross-dataset testing or calibration [53]. Frozen weights carry the backbone’s properties into the use; they do not show that the use transports. Single-lead hyperkalaemia detection has the fullest adapted-model profile of the five, with patient-level partitions, temporal and external cohorts and confidence intervals, but the report does not state that its prespecified threshold was applied unchanged at the external hospital, where it gives only the negative predictive value, and there is no comparator, calibration, subgroup or device analysis; a senior author is shared with the backbone [59]. Because the model was fine-tuned, the external evidence for ECGFounder is context, not inherited evidence, and a randomized trial of a different potassium-alert algorithm (Section 5) [85] informs how such a model should be evaluated, not whether it would help. Structural heart disease screening with ECG-FM was adapted by a group independent of the backbone’s developers against an echocardiographic reference standard; it outperformed a scratch network by a modest margin with protocol-aligned but not parameter-matched comparators, and had no external validation [55]. Evidence obtained on one release of one institution’s data is silent elsewhere. Interpretation of 77 conditions with DeepECG-SSL has the most complete matched comparison, with locked thresholds at collaborating external centres and near parity between self-supervised and supervised models, although the reported values differ slightly between sections of the article and between preprint and journal versions, so the comparison is coded unverified [14,57]; adapted-model evidence can be strong without any advantage of pretraining, and then says nothing in favour of pretraining. Reduced ejection fraction has the most complete conventional chain of any target, from multisite validation through randomized trials to economic modelling (Section 5) [9,65,80,81,91]. The foundation-model chain for DeepECG-SSL stops at the adapted model: its partitions are verified in the published Methods, but its comparison with the supervised model is unverified because the article gives different values in its Results and structured summary, and its external results appear only in supplementary tables [14]. We found no comparison of a foundation-model-based model with the algorithm tested in EAGLE, so none of the bridging conditions has been tested; the trial evidence for this target belongs to the conventional algorithm.

6.7. Using the Framework

For developers, the framework asks that each claim be made for a named object, with the adaptation procedure, mode of reuse, threshold and support declared and with an intended-use statement that justifies each requirement marked not applicable. For independent evaluators, it identifies where external evidence is scarcest, locked external validation, calibration at the intended prevalence and test–retest reliability, and asks that author relationships, competing interests and competing models be reported. For clinical investigators, it asks which object a study tests and which evidence the claim inherits; a silent evaluation can test the forecasts allowed by the adapted model’s operating characteristics, and a trial should report the mediators a later bridge would need. For journal reviewers, it suggests three questions: which object the claim concerns, whether the cited evidence is about that object or another that shares some of its components, and whether the intended-use statement justifies each exclusion. For healthcare systems, each local adaptation is a new object; a purchaser can ask a supplier for the evidence profile by object, the local acceptance test and a plan to measure alert burden, predictive value and clinician response before and after deployment.

6.8. Limits of the Framework

The principles are heuristic proposals, each with a falsifying finding (Table 4), and none has been tested. They differ in status: P2 rests on a mathematical bound whose empirical application depends on the probes tried; P3 restates a general statistical point, that evidence is silent outside its support; P1 and P5 are methodologically motivated hypotheses, the second with precedent in another field [94]; P4 is a precautionary decision rule, to be judged by its usefulness rather than tested as a regularity; and P6 is supported for conventional AI-ECG by the trials of Section 5 but untested for foundation models, as is P7. Feasible tests include controlled reuse experiments in which one backbone is used frozen, with parameter-efficient adaptation and with full fine-tuning, measuring which backbone properties (calibration, subgroup differences, sensitivity to acquisition) persist in each descendant (P1, P2); deliberately introducing a known acquisition shortcut during pretraining and measuring whether it propagates to descendants (P4); multi-site tests of an adaptation protocol and acceptance test, counting acceptable models rejected and unacceptable models accepted (P5); and silent evaluations comparing forecast with observed alert rates and predictive values, and head-to-head comparisons of successors with incumbents (P6, P7). Whether applying the framework changes appraisers’ conclusions is itself testable. The matrix was coded independently by two raters, as in the double scoring used for REAL-FM, but applied to a non-systematic search [102]; its states record whether evidence exists and how deeply we verified it, not study quality or effect size; the intended-use statements are ours, the uses were selected for their documented chains, and a different selection could give a different pattern, and several cells rest on preprints or abstracts. The states cannot be added up to a score. Independence has two senses here: that of an evaluation from a model’s developers, coded per model–evaluation pair from public author and institutional information that may miss relationships, and that of raters, which is partial. Both raters and the adjudicator are authors of this Review; the raters used AI-assisted extraction, and the third review was not blinded. Requiring a declared intended use limits, but cannot prevent, claims narrowed to avoid requirements. The framework has not been externally validated. Agreement between the two raters before adjudication was substantial (Section 6.5), but it measures reproducibility within the author team: it does not show that the codes are correct, and raters outside the team might code differently. Generative AI assisted the extraction of supporting evidence for both raters and the drafting of the adjudication proposals; each rater reviewed and confirmed his own codes against the sources, but assistance common to both raters may have increased their agreement (Supplementary Note 5). What can be checked now is documented: every cell other than a plain N has its source and rationale in Supplementary Table S11, and the tallies and agreement statistics in Section 6.5 can be recomputed from the machine-readable original and consensus codes in Supplementary Data 2; that recomputation checks transcription and arithmetic only. The conclusions we draw from the matrix (no intervention-level evidence, no independent locked external validation and no test–retest or device analysis for any use) rest on whole rows coded N, on which the two raters agreed in every cell but one device cell, which adjudication left N; that agreement shows that neither rater found such evidence in the sources examined, not that none exists. As anticipated, the disagreements lay at the boundaries between V and U and between U and N, and in the evaluator codes; adjudication reduced the verified cells from 25 to 21. The blank coding form and the original agreement plan remain available (Supplementary Data 1). Coding by raters outside the author team, on a systematic sample of models, and empirical tests of the principles are the necessary next steps.

7. ECG–Language Models, Governance and the Research Agenda

Treating an ECG foundation model as one shared component reused by many applications has three further consequences. ECG–language models add a second shared component whose evidence must be appraised separately. Governance arrangements regulate devices, not the platforms they are built on. And the gaps identified in Section 3, Section 4, Section 5 and Section 6 can be turned into a ranked set of studies.

7.1. ECG–Language Models: A Second Shared Component

Models that couple ECGs with text (Section 2 and Section 3) allow a class to be described in words rather than trained, and produce reports or answers rather than scores [24,25,26,27,104]. Their distinctive evidence problem is that a text output can be fluent and plausible while resting on features absent from the tracing, and the usual metrics do not detect this. The evaluations we read show it at three levels. For a generative model trained on raw waveforms, report quality was measured with text-overlap metrics and with labels extracted from reports by another language model, without expert review; retrieval of textbook knowledge with automated prompt tuning raised an automated faithfulness score from about 40 to 82, a measure of agreement with the retrieved text rather than with the ECG [104]. For a general-purpose multimodal model reading ECG images, a single-centre study of 80 ECGs found accuracy for normal versus abnormal of 0.53 without examples or guidance and 0.83 with ten examples and guidance, and 0.28–0.41 for six-class diagnosis, with outputs sensitive to prompt wording and no cardiologist comparator [105]. And a preprint framework that separates perception, whether features cited in a model’s reasoning can be verified in the signal, from deduction found that cited features could be fully verified in fewer than 10% of reasoning traces in most configurations and about 25–30% at best, and that accuracy correlated with deduction (r = 0.70) far more than with perception (r = 0.18) [106]. One author is affiliated with the developer of an evaluated model, and the text has no competing-interests statement; with that caveat, the study shows that accuracy and signal-grounded reasoning can diverge. A registered randomized vignette trial is now testing mandatory assistance from a version-locked general-purpose model for prehospital ECG interpretation [79].
An ECG–language model usually contains two shared components, an ECG encoder and a language model that is often general-purpose and updated by a third party. The identity principle applies to each, and under the fifth principle a change of language-model version creates a new object even if the encoder is unchanged, which is why version locking, as in the registered trial [79], matters for evidence. Three requirements are specific to this class: prompt sensitivity (requirement B7, not applicable to the signal-only backbones of the matrix); grounding, the verifiability in the signal of features cited in a text output, distinct from accuracy; and expert evaluation of free text, including the rate of clinically consequential errors. Reporting can follow TRIPOD-LLM [107]. We did not identify a clinical evaluation of an ECG–language model with expert review of its outputs against a reference standard in a defined population, a gap in the literature reviewed rather than evidence of poor performance.

7.2. Governance of a Shared Platform

Regulation attaches to a device with an intended use, not to the model a device is built on [73,74]. A backbone therefore enters regulatory review as a component of each device, and evidence about it is carried, if at all, by each submission. Three features of the framework bear on this.
The first is change. The United States Food and Drug Administration’s final guidance on predetermined change control plans allows a manufacturer to specify in advance the modifications it intends to make to an AI-enabled device, the methodology for developing, validating and implementing them and an assessment of their impact [108], and a draft guidance on lifecycle management extends the emphasis on the total product lifecycle [74]. A change control plan resembles our fifth principle, in which evidence attaches to a pre-specified procedure and acceptance test rather than to one fixed model, but it is defined by one manufacturer for one device, whereas foundation-model reuse can involve many adaptations at many sites, sometimes by the deploying institution. How local re-adaptation relates to a manufacturer’s plan is a regulatory question we do not attempt to answer; for evidence, a procedure-level claim is only as good as the multi-site evidence that the procedure and its acceptance test work, which we did not find for any ECG model.
The second is surveillance. Under the asymmetry principle a defect found in a backbone should trigger assessment of every device built on it, but post-market monitoring is organized by device. In the European Union, AI systems that are, or are safety components of, products covered by the harmonization legislation in Annex I of the Artificial Intelligence Act, including medical devices that require third-party conformity assessment, are classified as high-risk under its Article 6(1) [73]. The Digital Omnibus on AI, Regulation (EU) 2026/1744, amended Article 113 to defer the application of the requirements in Chapter III, Section 1, Section 2 and Section 3, to 2 August 2028 for systems classified as high-risk under Article 6(1) and Annex I, and to 2 December 2027 for systems classified under Article 6(2) and Annex III [109]. These dates apply to those classifications, not to every medical AI system. We did not identify, in the documents read, a mechanism that links the surveillance of different devices sharing a backbone. We propose that developers of a backbone maintain a versioned evidence file listing the pretraining corpus and its overlap audit, known defects and the tests for them, and the adapted models and devices derived from each version, so that a defect can be traced to every descendant; this is our proposal, not an existing requirement.
The third is independence and openness. The external evaluations in this Review all used openly released backbones [44,52,53,55], as did BenchECG [56], and all but BenchECG lacked a competing-interests statement in the texts we read. Open release enables the independent evaluation that the matrix shows is scarce, and also allows use outside regulated pathways. Federated training, in which sites share model updates rather than data, has so far been applied to task-specific ECG models, for example a convolutional–recurrent atrial fibrillation classifier developed on one public dataset [110]; for a backbone we expect it to make documentation of the pretraining corpus and overlap audits harder, not unnecessary. Journals and funders can strengthen the evidence by requiring competing-interests’ statements in preprints and benchmarks, by asking evaluators to disclose competing models, and by supporting evaluation on data held by groups that neither developed nor adapted the model, building on consensus guidance for trustworthy AI and updated risk-of-bias tools [111,112]. Equity follows the same logic: a backbone’s demographic and device composition is part of its support in the sense of the third principle, and subgroup performance at operating thresholds was identified, unverified, for one worked use only, as age and sex differences pooled across conditions (Section 6), and was not reported by group in the trials (Section 5).

7.3. A Research Agenda

Table 6 ranks the studies that would fill the largest gaps in the matrix; the gaps in generalization and prospective outcome-based validation resemble those identified for imaging foundation models [102]. The ranking is our judgment, favouring studies that test claims already made and whose results would change deployment decisions: locked external validation by independent evaluators, with calibration and performance at the declared threshold and intended prevalence (no use in the matrix had independent locked validation, and calibration was identified, unverified, for one use); head-to-head comparison at a matched alert rate with the conventional algorithm a successor would replace, which tests the bridging conditions of the seventh principle; silent evaluation; randomized evaluation that reports mediators, to which the registered trials (Section 5) will contribute only if they report them and identify the model deployed; tests of acquisition reliance, device-stratified analyses and test–retest agreement, for which approaches developed for robustness in computer vision, such as representations stabilized against image corruption by a transform domain in human parsing [113] and mask-guided fusion of visible and infrared features with a state-space architecture for drone-based detection [114], suggest designs that would need ECG-specific evaluation and are not evidence about ECG foundation models; and tests of the first and fifth principles, a systematic review with a full registry search and an inter-rater study of the coding guide by raters outside the author team. Further scaling, or new objectives evaluated only on public benchmarks with developer-chosen comparators, adds to the kind of evidence that is already the most abundant and the least connected to clinical use.
Table 6. A ranked research agenda for ECG foundation models, linked to the evidence requirements and principles of Section 6.

8. Conclusions and Outlook

The most consistently reported advantage of ECG foundation models is label efficiency: in several low-label comparisons, mostly against training from scratch, pretrained representations reduced the labelled data needed to reach a given performance, and in the only controlled estimate against a supervised baseline, made by a group that developed one of the three models and the baseline, the models needed 0.11 to 0.62 times as many labels on one dataset under one fine-tuning recipe, a result specific to those conditions [44]. Against strong supervised models with abundant labels, they have so far achieved parity or small gains; in the one controlled comparison of external transport, a self-supervised interpretation model transported no better than a matched supervised model [14]. In the few comparisons available, scale has not predicted performance. The evaluations that would establish robustness for clinical use, independent locked external validation, calibration at the intended prevalence, device-stratified analysis and test–retest reliability were not found, and no prospective trial of an ECG foundation model has reported; one registered trial may test one [75]. The clinical evidence for AI-enabled electrocardiography is real, but it concerns conventional algorithms, and its main lesson is that benefit depends on thresholds, workflows and clinician response that no model controls [9,87,88].
The platform–use framework explains why these findings do not add up to clinical readiness and what would. Evidence belongs to the object tested: the backbone, an adapted model or a deployed intervention. Some evidence may be inherited, under stated conditions, from a shared backbone by models that keep it intact; a defect in a shared component calls for assessment of each descendant because neither its propagation nor its absence can be assumed, and success in one use is not evidence for another; re-adaptation creates a new object; performance does not license claims of utility; and trial evidence for a conventional algorithm supports at most a presumption for a successor that replaces it with matched mediators. These are heuristic proposals with stated conditions for falsification, intended to make the scope of evidence explicit rather than to replace task-specific evidence, and testing them is part of the agenda we set out.
This Review has limits that the same standards expose. It is a critical synthesis, not a systematic review; several sources were read only as abstracts or preprints; the evidence matrix was coded by two of the authors, with substantial agreement before adjudication but no assessment by raters outside the author team, and the foundation-model criterion and its decision rules are provisional and untested; and the registry search covered two registries. Those limits are why we report the depth at which each claim was verified and treat absences as limits of our search.
For the next stage of the field, the priority is not larger backbones but better evidence about the objects that reach patients, produced by the designs and actors set out in Section 6 and Table 6. If that evidence is produced, the value of foundation models, particularly for rare conditions, new targets and underserved populations, can be shown rather than assumed.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/mca31060268/s1, Supplementary Information (Supplementary Notes 1–5 and Tables S1–S17: study-level extraction, generalization evidence, trial evidence, the evidence matrix with its coding guide, notes and sources, the registry search, the revision search, decision rules for classifying ECG foundation models, the intended-use scenario analysis and a minimum documentation checklist for pretraining–evaluation separation, and the coding, agreement and adjudication of the evidence matrix); Supplementary Data 1 (Excel workbook): blank coding form and original agreement-analysis plan for the evidence matrix, with a report of the procedure followed; Supplementary Data 2 (Excel workbook): both raters’ original codes, third-review and consensus codes, agreement statistics, recomputed tallies and the scenario analysis. References [115,116,117] are cited in the supplementary materials.

Author Contributions

Conceptualization, M.A.M., S.M.F. and R.Q.; methodology, M.A.M., T.S.A., M.A., S.M.F. and R.Q.; software, M.A.M. and R.Q.; validation, M.A.M., T.S.A. and M.A.; formal analysis, M.A.M. and M.A.-S.; investigation, M.A.M., T.S.A., M.A., S.M.F. and S.Z.M.A.; resources, T.S.A., M.A., S.M.F., S.Z.M.A. and R.Q.; data curation, M.A.M., T.S.A. and S.Z.M.A.; writing—original draft preparation, M.A.M.; writing—review and editing, M.A.M., T.S.A., M.A., S.M.F., S.Z.M.A., M.A.-S. and R.Q.; visualization, M.A.M. and S.M.F.; supervision, R.Q.; project administration and funding acquisition, M.A.M. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the Scientific Research Deanship at the University of Ha’il, Saudi Arabia, under project number RG-25 072.

Institutional Review Board Statement

Not applicable.

Data Availability Statement

The study-level extraction, evidence-matrix coding criteria, supporting notes, and revision analyses are provided in the Supplementary Information (Tables S1–S17). The original blank coding form and agreement plan are provided in Supplementary Data 1, while the procedure completed during revision and deviations from that plan are documented in Supplementary Note 5. Both raters’ original codes, third-review and consensus codes, agreement statistics, recomputed tallies, and the intended-use scenario analysis are provided in Supplementary Data 2.

Acknowledgments

Generative AI was used to improve manuscript clarity, coherence, and flow after the authors independently developed, discussed, and drafted the scientific content.

Conflicts of Interest

The authors declare no conflicts of interest.

Abbreviations

The following abbreviations are used in this manuscript:
AFatrial fibrillation
AIartificial intelligence
AUROCarea under the receiver operating characteristic curve
CIconfidence interval
CLDchronic liver disease
CTcomputed tomography
ECGelectrocardiogram
EDemergency department
EFejection fraction
FMfoundation model
FPRfalse-positive rate
HRhazard ratio
ICERincremental cost-effectiveness ratio
IRRincidence rate ratio
LVEFleft ventricular ejection fraction
LVSDleft ventricular systolic dysfunction
ORodds ratio
PPVpositive predictive value
QALYquality-adjusted life-year
RCTrandomized controlled trial
SSLself-supervised learning
STEMIST-elevation myocardial infarction
TPRtrue-positive rate
TTEtransthoracic echocardiography

References

  1. Hannun, A.Y.; Rajpurkar, P.; Haghpanahi, M.; Tison, G.H.; Bourn, C.; Turakhia, M.P.; Ng, A.Y. Cardiologist-level arrhythmia detection and classification in ambulatory electrocardiograms using a deep neural network. Nat. Med. 2019, 25, 65–69, Correction in Nat. Med. 2019, 25, 530. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  2. Ribeiro, A.H.; Ribeiro, M.H.; Paixão, G.M.M.; Oliveira, D.M.; Gomes, P.R.; Canazart, J.A.; Ferreira, M.P.S.; Andersson, C.R.; Macfarlane, P.W.; Meira, W.; et al. Automatic diagnosis of the 12-lead ecg using a deep neural network. Nat. Commun. 2020, 11, 1760, Correction in Nat. Commun. 2020, 11, 2227. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  3. Attia, Z.I.; Kapa, S.; López-Jiménez, F.; McKie, P.M.; Ladewig, D.J.; Satam, G.; Pellikka, P.A.; Enriquez-Sarano, M.; Noseworthy, P.A.; Munger, T.M.; et al. Screening for cardiac contractile dysfunction using an artificial intelligence-enabled electrocardiogram. Nat. Med. 2019, 25, 70–74. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  4. Attia, Z.I.; Noseworthy, P.A.; López-Jiménez, F.; Asirvatham, S.J.; Deshmukh, A.; Gersh, B.J.; E Carter, R.; Yao, X.; Rabinstein, A.A.; Erickson, B.J.; et al. An artificial intelligence-enabled ecg algorithm for the identification of patients with atrial fibrillation during sinus rhythm: A retrospective analysis of outcome prediction. Lancet 2019, 394, 861–867. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  5. Raghunath, S.; Ulloa, A.; Jing, L.; vanMaanen, D.P.; Stough, J.V.; Hartzel, D.N.; Leader, J.B.; Kirchner, H.L.; Stumpe, M.C.; Hafez, A.; et al. Prediction of mortality from 12-lead electrocardiogram voltage data using a deep neural network. Nat. Med. 2020, 26, 886–891. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  6. Siontis, K.C.; Noseworthy, P.A.; Attia, Z.I.; Friedman, P.A. Artificial intelligence-enhanced electrocardiography in cardiovascular disease management. Nat. Rev. Cardiol. 2021, 18, 465–478. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  7. Attia, Z.I.; Harmon, D.M.; Behr, E.R.; Friedman, P.A. Application of artificial intelligence to the electrocardiogram. Eur. Heart J. 2021, 42, 4717–4730. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  8. Lin, C.-S.; Liu, W.-T.; Chen, Y.-H.; Lin, S.-H.; Lin, C. Artificial intelligence-enabled electrocardiography from scientific research to clinical application. EMBO Mol. Med. 2026, 18, 22–40. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  9. Yao, X.; Rushlow, D.R.; Inselman, J.; McCoy, R.G.; Thacher, T.D.; Behnken, E.; Bernard, M.; Rosas, S.; Akfaly, A.; Misra, A.; et al. Artificial intelligence-enabled electrocardiograms for identification of patients with low ejection fraction: A pragmatic, randomized clinical trial. Nat. Med. 2021, 27, 815–819. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  10. Lin, C.-S.; Liu, W.-T.; Tsai, D.-J.; Lou, Y.-S.; Chang, C.-H.; Lee, C.-C.; Fang, W.-H.; Wang, C.-C.; Chen, Y.-Y.; Lin, W.-S.; et al. AI-enabled electrocardiography alert intervention and all-cause mortality: A pragmatic randomized clinical trial. Nat. Med. 2024, 30, 1461–1470. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  11. Bommasani, R.; Hudson, D.A.; Adeli, E.; Altman, R.; Arora, S.; Liang, P. On the opportunities and risks of foundation models. arXiv 2021. [Google Scholar] [CrossRef] [Scilit]
  12. Moor, M.; Banerjee, O.; Abad, Z.S.H.; Krumholz, H.M.; Leskovec, J.; Topol, E.J.; Rajpurkar, P. Foundation models for generalist medical artificial intelligence. Nature 2023, 616, 259–265. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  13. Li, J.; Aguirre, A.D.; Moura, V.; Jin, J.; Liu, C.; Zhong, L.; Sun, C.; Clifford, G.D.; Westover, M.B.; Hong, S. An electrocardiogram foundation model built on over 10 million recordings. NEJM AI 2025, 2. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  14. Nolin-Lapalme, A.; Sowa, A.; Delfrate, J.; Tastet, O.; Corbin, D.; Kulbay, M.; Ozdemir, D.; Noël, M.-J.; Marois-Blanchet, F.-C.; Harvey, F.; et al. Foundation models for electrocardiogram interpretation: Clinical implications. Eur. Heart J. 2026, 47, 2174–2186, Correction in Eur. Heart J. 2026, 47, 2223. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  15. Han, Y.; Murino, V.; Liu, X.; Zhang, X.; Ding, C. A systematic review on foundation models for electrocardiogram analysis: Initial strides and expansive horizons. arXiv 2024. [Google Scholar] [CrossRef] [Scilit]
  16. Khan, M.H.; Nayfeh, A.; Masood, M.; Al-Shaikhi, A.; Rahman, M.M.U.; Al-Naffouri, T.Y. Ecg foundation models and medical llms for agentic cardiovascular intelligence at the edge: A review and outlook. arXiv 2026. [Google Scholar] [CrossRef] [Scilit]
  17. Bollmann, A.; Pradler, V.; Husser, D.; Kim, I.; Hohenstein, S.; Nitsche, A.; Kwast, S.; Kannt, O.; Pawlu, C.; Moscho, A.; et al. Artificial intelligence-enabled electrocardiography for assessment of left ventricular systolic dysfunction in the era of foundation models. Front. Cardiovasc. Med. 2026, 13, 1899224. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  18. Ye, J.; Bronstein, S.; Abu Hashish, M. Foundation models for cardiovascular diseases and medicine. Eur. Heart J.—Digit. Health 2026, 7, ztag113. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  19. Chen, H.; Huang, J.; Hou, X. Translational maturity of artificial intelligence-enabled electrocardiography varies across cardiovascular diseases. Front. Cardiovasc. Med. 2026, 13, 1940621. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  20. Wornow, M.; Xu, Y.; Thapa, R.; Patel, B.; Steinberg, E.; Fleming, S.L.; Pfeffer, M.A.; Fries, J.; Shah, N.H. The shaky foundations of large language models and foundation models for electronic health records. npj Digit. Med. 2023, 6, 135. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  21. Na, Y.; Park, M.; Tae, Y.; Joo, S. Guiding masked representation learning to capture spatio-temporal relationship of electrocardiogram. arXiv; 2024.
  22. McKeen, K.; Masood, S.; Toma, A.; Rubin, B.; Wang, B. Ecg-fm: An open electrocardiogram foundation model. JAMIA Open 2025, 8, ooaf122. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  23. Coppola, E.; Savardi, M.; Massussi, M.; Adamo, M.; Metra, M.; Signoroni, A. Hubert-ecg as a self-supervised foundation model for broad and scalable cardiac applications. medRxiv 2024. [Google Scholar] [CrossRef] [Scilit]
  24. Liu, C.; Wan, Z.; Ouyang, C.; Shah, A.; Bai, W.; Arcucci, R. Zero-shot ecg classification with multimodal learning and test-time clinical knowledge enhancement. PMLR 2024, 235, 31949–31963. [Google Scholar]
  25. Ko, M.; Gadaleta, M.; Topol, E.J.; Muse, E.D.; Quer, G. Development and external validation of a contrastive learning foundation model for ecg-based prediction of cardiovascular diseases and outcomes. Lancet Digit. Health 2026, 8, 101092. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  26. Wang, F.; Xu, J.; Yu, L. From token to rhythm: A multi-scale approach for ecg-language pretraining. arXiv 2025. [Google Scholar] [CrossRef] [Scilit]
  27. Liu, R.; Bai, Y.; Yue, X.; Zhang, P. Teaching multimodal LLMs to comprehend 12-lead electrocardiographic images. npj Digit. Med. 2026, 9, 349. [Google Scholar] [CrossRef] [Scilit]
  28. Lima, E.M.; Ribeiro, A.H.; Paixão, G.M.M.; Ribeiro, M.H.; Filho, M.M.P.; Gomes, P.R.; Oliveira, D.M.; Sabino, É.C.; Duncan, B.B.; Giatti, L.; et al. Deep neural network-estimated electrocardiographic age as a mortality predictor. Nat. Commun. 2021, 12, 5117. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  29. Hu, S.M.; Barrios, J.P.; Tison, G.H. A deep foundation model for electrocardiogram interpretation: Enabling rare disease detection through transfer learning. Eur. Heart J.—Digit. Health 2025, 6, 619–623. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  30. Kiyasseh, D.; Zhu, T.; Clifton, D.A. Clocs: Contrastive learning of cardiac signals across space, time, and patients. PMLR 2021, 139, 5606–5615. [Google Scholar]
  31. Diamant, N.; Reinertsen, E.; Song, S.; Aguirre, A.D.; Stultz, C.M.; Batra, P. Patient contrastive learning: A performant, expressive, and practical approach to electrocardiogram modeling. PLoS Comput. Biol. 2022, 18, e1009862. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  32. Mehari, T.; Strodthoff, N. Self-supervised representation learning from 12-lead ecg data. Comput. Biol. Med. 2022, 141, 105114. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  33. Lin, S.; Li, Z.; Wu, Q.; Chen, Y.; Yang, Y.; Zhao, H. A self-supervised electrocardiogram foundation model for empowering cardiovascular disease prediction and genetic factor discovery. Nat. Commun. 2026, 17, 5771. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  34. Yang, Y.; Peracchio, L.; Mayourian, J.; Miller, T.; La Cava, W. An ecg foundation model for generalizable cardiac function prediction across the lifespan. medRxiv 2026. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  35. Schläpfer, J.; Wellens, H.J. Computer-interpreted electrocardiograms. J. Am. Coll. Cardiol. 2017, 70, 1183–1192. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  36. Malmivuo, J.A.; Plonsey, R. Bioelectromagnetism: Principles and Applications of Bioelectric and Biomagnetic Fields; Oxford University Press: Oxford, UK, 1995. [Google Scholar]
  37. Chen, T.; Kornblith, S.; Norouzi, M.; Hinton, G. A simple framework for contrastive learning of visual representations. PMLR 2020, 119, 1597–1607. [Google Scholar]
  38. Abbaspourazad, S.; Elachqar, O.; Miller, A.C.; Emrani, S.; Nallasamy, U.; Shapiro, I. Large-scale training of foundation models for wearable biosignals. arXiv 2024. [Google Scholar] [CrossRef] [Scilit]
  39. van den Oord, A.; Li, Y.; Vinyals, O. Representation learning with contrastive predictive coding. arXiv 2018. [Google Scholar] [CrossRef] [Scilit]
  40. Assran, M.; Duval, Q.; Misra, I.; Bojanowski, P.; Vincent, P.; Rabbat, M.; LeCun, Y.; Ballas, N. Self-supervised learning from images with a joint-embedding predictive architecture. In Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR); IEEE: New York, NY, USA, 2023; pp. 15619–15629. [Google Scholar]
  41. Kim, S. Learning general representation of 12-lead electrocardiogram with a joint-embedding predictive architecture. arXiv 2024. [Google Scholar] [CrossRef] [Scilit]
  42. Al-Masud, M.; Strodthoff, A.N. Pretraining strategies and scaling for ecg foundation models: A systematic study. arXiv 2026. [Google Scholar] [CrossRef] [Scilit]
  43. Radford, A.; Kim, J.W.; Hallacy, C.; Ramesh, A.; Goh, G.; Agarwal, S.; Sastry, G.; Askell, A.; Mishkin, P.; Clark, J.; et al. Learning transferable visual models from natural language supervision. PMLR 2021, 139, 8748–8763. [Google Scholar]
  44. Al-Masud, M.A.; Alcaraz, J.M.L.; Strodthoff, N. Benchmarking ecg fms: A reality check across clinical tasks. arXiv 2026. [Google Scholar] [CrossRef] [Scilit]
  45. Yeung, M.W.; van de Leur, R.R.; Benjamins, J.W.; Vessies, M.B.; Ruijsink, B.; Puyol-Antón, E.; van Tintelen, J.P.; Verweij, N.; van Es, R.; van der Harst, P. Deep representation learning of electrocardiogram reveals biological insights in cardiac phenotypes and cardiovascular diseases. iScience 2025, 28, 113226. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  46. Xiao, Y.; Zhao, Q.; Tang, G.; Zhang, H.; Kan, Z.; Zhang, D.; Li, J.; Nie, G.; Fang, X.; Wang, H.; et al. Fine-tuning an ecg foundation model to predict coronary CT angiography outcomes. npj Digit. Med. 2026. [Google Scholar] [CrossRef] [Scilit]
  47. Hu, E.J.; Shen, Y.; Wallis, P.; Allen-Zhu, Z.; Li, Y.; Wang, S.; Wang, L.; Chen, W. LoRA: Low-rank adaptation of large language models. arXiv 2022. [Google Scholar] [CrossRef] [Scilit]
  48. Abrar, M.F.; Saqib, M.; Ali, S.; Lee, I.E.; Khan, A.; Jan, S.; Alkhayyat, A. Automated heart disease detection using swin transformer and ecg signal processing: A high-accuracy approach. Sci. Rep. 2025, 15, 39338. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  49. Wagner, P.; Strodthoff, N.; Bousseljot, R.-D.; Kreiseler, D.; Lunze, F.I.; Samek, W.; Schaeffter, T. Ptb-xl, a large publicly available electrocardiography dataset. Sci. Data 2020, 7, 154. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  50. Gow, B.; Pollard, T.; Nathanson, L.A.; Johnson, A.; Moody, B.; Fernandes, C.; Greenbaum, N.; Waks, J.W.; Eslami, P.; Carbonati, T.; et al. Mimic-iv-ecg: Diagnostic Electrocardiogram Matched Subset, Version 1.0; Dataset; 2023. Available online: https://physionet.org/content/mimic-iv-ecg/1.0/ (accessed on 1 November 2026).
  51. Perez Alday, E.A.; Gu, A.; Shah, A.; Robichaux, C.; Wong, A.-K.I.; Liu, C.; Liu, F.; Rad, A.B.; Elola, A.; Seyedi, S.; et al. Classification of 12-lead ecgs: The physionet/computing in cardiology challenge 2020. Physiol. Meas. 2020, 41, 124003. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  52. Filice, F.; De Rose, E.; Bartucci, S.; Calimeri, F.; Perri, S. Looking beyond accuracy: A holistic benchmark of ecg foundation models. arXiv 2026. [Google Scholar] [CrossRef] [Scilit]
  53. Taleshinosrati, A.; Wang, Y.; Phoemsuk, A.; Abolghasemi, V.; Motlagh, N.H.; Puthusserypady, S.; Teichmann, D.; Peimankar, A. Found-af: Benchmarking ecg foundation models for atrial fibrillation detection. arXiv 2026. [Google Scholar] [CrossRef] [Scilit]
  54. Bollmann, A.; Kim, I.; Hohenstein, S.; Nitsche, M.; Koehler, L.; Schemmer, M.; Schmitz, P.; Pernstecher, V.; Koenig, S.; Leiner, J.; et al. Transformer-based ecg foundation and deep learning models for assessment of left ventricular systolic dysfunction. Eur. Heart J.—Digit. Health 2026, 7, ztaf143.045. [Google Scholar] [CrossRef] [Scilit]
  55. Do, D.N.; Do, M.N.; Nguyen, D.H.; Le, K.T.Q.; Pham, K.D.; Huynh, H.N.; Pham-Van-Hoang, P.; Huynh, Q.K.; Odat, R.M.; Ashar, P.; et al. Domain-adapted fine-tuning of ecg foundation models for multi-label structural heart disease screening. arXiv. 2026. [CrossRef] [Scilit]
  56. Lunelli, R.; Nicolson, A.; Pröll, S.M.; Reinstadler, S.J.; Bauer, A.; Dlaska, C. BenchECG and xECG: A benchmark and baseline for ECG foundation models. npj Digit. Med. 2026. [Google Scholar] [CrossRef] [Scilit]
  57. Nolin-Lapalme, A.; Sowa, A.; Delfrate, J.; Tastet, O.; Corbin, D.; Kulbay, M.; Ozdemir, D.; Noel, M.-J.; Marois-Blanchet, F.-C.; Harvey, F.; et al. Foundation models for generalizable electrocardiogram interpretation: Comparison of supervised and self-supervised electrocardiogram foundation models. medRxiv 2025. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  58. Lee, S.; Son, J.-W.; Kim, S.-A.; Ahn, M.-S.; Lee, S.J.; Han, S.-J.; Joo, T.; Na, Y.; Joo, S.; Ahn, H.J.; et al. Deep learning model using transfer learning for detecting left ventricular systolic dysfunction: Retrospective algorithm development and validation study. JMIR Med. Inform. 2026, 14, e83127. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  59. Tang, G.; Zhao, Q.; Nie, G.; Xiao, Y.; Geng, S.; Xie, D.; Huang, S.; Zhang, D.; Yao, X.; Wang, J.; et al. Artificial intelligence-enabled single-lead ecg for non-invasive hyperkalemia detection: Development, multicenter validation, and proof-of-concept deployment. arXiv 2026. [Google Scholar] [CrossRef] [Scilit]
  60. Hsieh, P.N.; Agrawal, P.; Alok, A.; Kumar, S.; Ramanathan, C.; Murthy, V.L.; Varma, N.; Nagarajan, V.; Ambrosy, A.P.; Ramsis, M.; et al. Artificial intelligence electrocardiography for left ventricular systolic dysfunction demonstrates preserved performance across demographic training imbalances. Eur. Heart J.—Digit. Health 2026, 7, ztag080. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  61. Monachino, G.; Zanchi, B.; Farina, G.; Faraci, F.D. Beyond full fine-tuning: Towards enhanced generalizability in downstream ecg foundation model adaptation. Sci. Rep. 2026, 71351. [Google Scholar] [CrossRef] [Scilit]
  62. Monachino, G.; La Porta, N.; Zanchi, B.; Fiorillo, L.; Rossi, A.D.; Farina, G.; Faraci, F.D. Self-dana: A resource-efficient channel-adaptive self-supervised approach for ecg foundation models. arXiv 2025. [Google Scholar] [CrossRef] [Scilit]
  63. Nguyen, H.D.; Pham, T.-T.; Le, N.; Nguyen, V. Tolerantecg: A foundation model for imperfect electrocardiogram. arXiv. 2025. [CrossRef] [Scilit]
  64. Dhingra, L.S.; Croon, P.M.; Batinica, B.; Oikonomou, E.K.; Khera, R. Test-retest reliability of artificial intelligence-enhanced electrocardiography: A multi-center study. medRxiv 2025. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  65. Carter, R.E.; Johnson, P.W.; Strom, J.B.; Waks, J.W.; Krumerman, A.; Ferrick, K.J.; DeRaad, R.; Steinberg, B.A.; Wieczorek, M.A.; Cruz, J.; et al. Multisite, external validation of an AI-enabled ecg algorithm for detection of low ejection fraction. JACC Adv. 2026, 5, 102537. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  66. Strodthoff, N.; Wagner, P.; Schaeffter, T.; Samek, W. Deep learning for ecg analysis: Benchmarks and insights from ptb-xl. IEEE J. Biomed. Health Inform. 2021, 25, 1519–1528. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  67. Scagnetto, A. Ecg biometrics with arcface-inception: External validation on mimic and heedb. arXiv 2026. [Google Scholar] [CrossRef] [Scilit]
  68. Sangha, V.; Mortazavi, B.J.; Haimovich, A.D.; Ribeiro, A.H.; Brandt, C.A.; Jacoby, D.L.; Schulz, W.L.; Krumholz, H.M.; Ribeiro, A.L.P.; Khera, R. Automated multilabel diagnosis on electrocardiographic images and signals. Nat. Commun. 2022, 13, 1583. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  69. Lee, H.; Kim, Y.; Sykora, D.; Ryu, A.J.; Cho, Y.; Kim, J.; Song, J. External validation of ecg artificial intelligence for emergency and cardiac assessment across a large-scale u.S. Healthcare system. npj Digit. Med. 2026, 9, 509. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  70. Sau, A.; Pastika, L.; Sieliwonczyk, E.; Patlatzoglou, K.; Ribeiro, A.H.; A McGurk, K.; Zeidaabadi, B.; Zhang, H.; Macierzanka, K.; Mandic, D.; et al. Artificial intelligence-enabled electrocardiogram for mortality and cardiovascular risk estimation: A model development and validation study. Lancet Digit. Health 2024, 6, e791–e802, Correction in Lancet Digit. Health 2024, 6, e882. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  71. Noseworthy, P.A.; Attia, Z.I.; Brewer, L.C.; Hayes, S.N.; Yao, X.; Kapa, S.; Friedman, P.A.; López-Jiménez, F. Assessing and mitigating bias in medical artificial intelligence: The effects of race and ethnicity on a deep learning model for ecg analysis. Circ. Arrhythmia Electrophysiol. 2020, 13, e007988. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  72. Otabor, E.; Hassan, A.; Okunlola, A.; Lam, J.; Alomari, L.; Hamilton, M. Transportability of an artificial intelligence electrocardiography model for structural heart disease: External validation and recalibration of echonext-mini in mimic-iv. Eur. Heart J.—Digit. Health 2026, 7, ztag147. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  73. Hospital, T. Effect of Smartwatch Along with Foundation Model for the Monitoring and Management of Acute Myocardial Infarction Patients During Outpatient Cardiac Rehabilitation After Percutaneous Coronary Intervention: Protocol for a Randomised Controlled Multicentre Trial (nct07395648). ClinicalTrials.gov. 2026. Available online: https://clinicaltrials.gov/study/NCT07395648 (accessed on 1 November 2026).
  74. Poterucha, T.J.; Jing, L.; Ricart, R.P.; Adjei-Mosi, M.; Finer, J.; Hartzel, D.; Kelsey, C.; Long, A.; Rocha, D.; Ruhl, J.A.; et al. Detecting structural heart disease from electrocardiograms using AI. Nature 2025, 644, 221–230. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  75. Institute, M.H. Harnessing Ecg Artificial Intelligence for Rapid Treatment and Accurate Interpretation, an Open Label Randomized Controlled Trial (heart-AI; nct06462989). ClinicalTrials.gov. 2024. Available online: https://clinicaltrials.gov/study/NCT06462989 (accessed on 1 November 2026).
  76. Institute, M.H. Deployment and Evaluation of Artificial Intelligence Software for Electrocardiogram Analysis and Management in Primary Care (Daisea-Ecg; nct06637293). ClinicalTrials.gov. 2024. Available online: https://clinicaltrials.gov/study/NCT06637293 (accessed on 1 November 2026).
  77. Ambulanciers, É.S.d.S. AI & Prehospital Ecg Analysis: A Randomized Controlled Trial of a Smartphone Large Language Model for Occlusion Myocardial Infarction Detection by Prehospital Providers (ecg-ia; nct07810686). ClinicalTrials.gov. 2026. Available online: https://clinicaltrials.gov/study/NCT07810686 (accessed on 1 November 2026).
  78. Tsai, D.-J.; Lin, C.; Liu, W.-T.; Lee, C.-C.; Chang, C.-H.; Lin, W.-Y.; Liu, Y.-L.; Chang, D.-W.; Hsieh, P.-H.; Tsai, C.-S.; et al. Artificial intelligence-assisted diagnosis and prognostication in low ejection fraction using electrocardiograms in inpatient department: A pragmatic randomized controlled trial. BMC Med. 2025, 23, 342. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  79. Adedinsewo, D.; Morales-Lara, A.C.; Afolabi, B.B.; Kushimo, O.A.; Mbakwem, A.C.; Ibiyemi, K.F.; Ogunmodede, J.A.; Raji, H.O.; Ringim, S.H.; Habib, A.A.; et al. Artificial intelligence guided screening for cardiomyopathies in an obstetric population: A pragmatic randomized clinical trial. Nat. Med. 2024, 30, 2897–2906. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  80. Kelshiker, M.A.; Bächtiger, P.; Petri, C.F.; Nakhare, S.; Mansell, J.; Chhatwal, K.; Alrumayh, A.; Zaman, J.; Shah, M.; Young, H.; et al. Triple cardiovascular disease detection with an artificial intelligence-enabled stethoscope (tricorder) in the uk: A cluster-randomised controlled implementation trial. Lancet 2026, 407, 704–715. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  81. Simonetto, D.A.; Rushlow, D.; Liu, K.; Calleri, A.; Kassmeyer, B.A.; Lennon, R.J.; Rattan, P.; Bernard, M.E.; Singh, G.; Deyo-Svendsen, M.E.; et al. Detection of undiagnosed liver cirrhosis via AI-enabled electrocardiogram: A pragmatic, cluster-randomized clinical trial. Nat. Med. 2026, 32, 160–167, Correction in Nat. Med. 2026, 32, 1160. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  82. Lin, C.; Liu, W.-T.; Chang, C.-H.; Lee, C.-C.; Hsing, S.-C.; Fang, W.-H.; Tsai, D.-J.; Chen, K.-C.; Lee, C.-H.; Cheng, C.-C.; et al. Artificial intelligence-powered rapid identification of st-elevation myocardial infarction via electrocardiogram (arise): A pragmatic randomized controlled trial. NEJM AI 2024, 1. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  83. Lin, C.; Lin, C.-S.; Chen, S.-J.; Tsai, S.-H.; Sung, C.-C.; Chen, C.-C.; Hsu, Y.-J.; Hung, Y.-J.; Lin, S.-H. AI-enabled electrocardiogram alert for potassium imbalance treatment: A pragmatic randomized controlled trial. Nat. Commun. 2026, 17, 159. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  84. Noseworthy, P.A.; Attia, Z.I.; Behnken, E.; Giblon, R.; Bews, K.A.; Liu, S.; Gosse, T.; Linn, Z.D.; Deng, Y.; Yin, J.; et al. Artificial intelligence-guided screening for atrial fibrillation using electrocardiogram during sinus rhythm: A prospective non-randomised interventional trial. Lancet 2022, 400, 1206–1212. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  85. Rushlow, D.R.; Croghan, I.T.; Inselman, J.W.; Thacher, T.D.; Friedman, P.A.; Yao, X.; Pellikka, P.A.; Lopez-Jimenez, F.; Bernard, M.E.; Barry, B.A.; et al. Clinician adoption of an artificial intelligence algorithm to detect left ventricular systolic dysfunction in primary care. Mayo Clin. Proc. 2022, 97, 2076–2085. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  86. Calleri, A.; Yazarkan, Y.; Liu, K.; Kassmeyer, B.A.; Lennon, R.J.; Rattan, P.; Seid, A.; Bernard, M.E.; Singh, G.; Deyo-Svendsen, M.E.; et al. Clinician engagement shapes the impact of AI-based ecg screening for chronic liver disease in primary care. npj Digit. Med. 2026, 9, 553. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  87. Vedage, N.A.; Friedman, S.F.; Chang, Y.; Borowsky, L.H.; Shah, S.J.; McManus, D.D.; Atlas, S.J.; Singer, D.E.; Lubitz, S.A.; Maddah, M.; et al. Risk-guided atrial fibrillation screening with artificial intelligence-enabled electrocardiogram models: A vital-af trial analysis. J. Am. Coll. Cardiol. 2026, 87, 1798–1813. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  88. Khurshid, S.; Friedman, S.F.; Al-Alusi, M.A.; Kany, S.; Sommers, T.F.; Anderson, C.D.; Ho, J.E.; McManus, D.D.; Borowsky, L.H.; Ashburner, J.M.; et al. Artificial intelligence-enabled analysis of handheld single-lead electrocardiograms to predict incident atrial fibrillation: An analysis of the vital-af randomized trial. npj Digit. Med. 2025, 8, 776. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  89. Thao, V.; Zhu, Y.; Tseng, A.S.; Inselman, J.W.; Borah, B.J.; McCoy, R.G.; Attia, Z.I.; Lopez-Jimenez, F.; Pellikka, P.A.; Rushlow, D.R.; et al. Cost-effectiveness of artificial intelligence-enabled electrocardiograms for early detection of low ejection fraction: A secondary analysis of the electrocardiogram artificial intelligence-guided screening for low ejection fraction trial. Mayo Clin. Proc. Digit. Health 2024, 2, 620–631. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  90. Ong, A.Q.C.; Ang, C.-S.; Bojic, I.; Johnson, C.L.; Aggour, H.; Ng, F.S.; Car, J.; Leeson, P.; Gonçalves, J.; Lai, N.M. Artificial intelligence in cardiovascular care: A systematic review and meta-analysis of randomised controlled trials. eClinicalMedicine 2026, 98, 104123. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  91. Hadida Barzilai, D.; Sudri, K.; Goshen, G.; Klang, E.; Zimlichman, E.; Barbash, I.; Shelly, M.C. Randomized controlled trials evaluating artificial intelligence in cardiovascular care: A systematic review. JACC Adv. 2025, 4, 102152. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  92. Guo, L.L.; Fries, J.; Steinberg, E.; Fleming, S.L.; Morse, K.; Aftandilian, C.; Posada, J.; Shah, N.; Sung, L. A multi-center study on the adaptability of a shared foundation model for electronic health records. npj Digit. Med. 2024, 7, 171. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  93. Fryback, D.G.; Thornbury, J.R. The efficacy of diagnostic imaging. Med. Decis. Mak. 1991, 11, 88–94. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  94. Goldsack, J.C.; Coravos, A.; Bakker, J.P.; Bent, B.; Dowling, A.V.; Fitzer-Attas, C.; Godfrey, A.; Godino, J.G.; Gujar, N.; Izmailova, E.; et al. Verification, analytical validation, and clinical validation (v3): The foundation of determining fit-for-purpose for biometric monitoring technologies (biomets). npj Digit. Med. 2020, 3, 55. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  95. Collins, G.S.; Moons, K.G.M.; Dhiman, P.; Riley, R.D.; Beam, A.L.; Van Calster, B.; Ghassemi, M.; Liu, X.; Reitsma, J.B.; van Smeden, M.; et al. Tripod+AI statement: Updated guidance for reporting clinical prediction models that use regression or machine learning methods. BMJ 2024, 385, e078378, Correction in BMJ 2024, 385, q902. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  96. Sounderajah, V.; Guni, A.; Liu, X.; Collins, G.S.; Karthikesalingam, A.; Markar, S.R.; Golub, R.M.; Denniston, A.K.; Shetty, S.; Moher, D.; et al. The stard-AI reporting guideline for diagnostic accuracy studies using artificial intelligence. Nat. Med. 2025, 31, 3283–3289, Correction in Nat. Med. 2026, 32, 3493. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  97. Vasey, B.; Nagendran, M.; Campbell, B.; Clifton, D.A.; Collins, G.S.; Denaxas, S.; Denniston, A.K.; Faes, L.; Geerts, B.; Ibrahim, M.; et al. Reporting guideline for the early-stage clinical evaluation of decision support systems driven by artificial intelligence: Decide-AI. Nat. Med. 2022, 28, 924–933. [Google Scholar] [CrossRef] [PubMed]
  98. Liu, X.; Cruz Rivera, S.; Moher, D.; Calvert, M.J.; Denniston, A.K. The SPIRIT-AI and CONSORT-AI Working Group. Reporting guidelines for clinical trial reports for interventions involving artificial intelligence: The consort-AI extension. Nat. Med. 2020, 26, 1364–1374. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  99. Rivera, S.C.; Liu, X.; Chan, A.-W.; Denniston, A.K.; Calvert, M.J.; SPIRIT-AI; CONSORT-AI Working Group. Guidelines for clinical trial protocols for interventions involving artificial intelligence: The spirit-AI extension. Nat. Med. 2020, 26, 1351–1363. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  100. Muneer, A.; Zhang, K.; Hamdi, I.; Qureshi, R.; Waqas, M.; Fouad, S.; Ali, H.; Anwar, S.M.; Wu, J. Foundation models in biomedical imaging: Turning hype into reality. Nat. Biomed. Eng. 2026, 10, 1557–1575. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  101. Kwong, J.C.C.; Erdman, L.; Khondker, A.; Skreta, M.; Goldenberg, A.; McCradden, M.D.; Lorenzo, A.J.; Rickard, M. The silent trial—The bridge between bench-to-bedside clinical AI applications. Front. Digit. Health 2022, 4, 929508. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  102. Zhao, Y.; Kang, J.; Zhang, T.Y.; Han, P.; Chen, T. Ecg-chat: A large ecg-language model for cardiac disease diagnosis. In IEEE International Conference on Multimedia and Expo (ICME); IEEE: New York, NY, USA, 2025. [Google Scholar]
  103. Engelstein, H.; Ramon-Gonen, R.; Sabbag, A.; Klang, E.; Sudri, K.; Cohen-Shelly, M.; Barbash, I. Effectiveness of the gpt-4o model in interpreting electrocardiogram images for cardiac diagnostics: Diagnostic accuracy study. JMIR AI 2025, 4, e74426. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  104. Xu, M.A.; Haresamudram, H.; Liu, C.W.; Langer, P.; Pradeepkumar, J.; Mao, W.; Ferns, S.J.; Verma, A.; Sun, J.; Schmiedmayer, P.; et al. How well do multimodal models reason on ecg signals? arXiv 2026. [Google Scholar] [CrossRef] [Scilit]
  105. Gallifant, J.; Afshar, M.; Ameen, S.; Aphinyanaphongs, Y.; Chen, S.; Cacciamani, G.; Demner-Fushman, D.; Dligach, D.; Daneshjou, R.; Fernandes, C.; et al. The tripod-llm reporting guideline for studies using large language models. Nat. Med. 2025, 31, 60–69. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  106. European Union. Regulation (eu) 2024/1689 of the European Parliament and of the Council Laying Down Harmonised Rules on Artificial Intelligence (Artificial Intelligence Act); European Union: Brussels, Belgium, 2024. [Google Scholar]
  107. U.S. Food and Drug Administration. Artificial Intelligence-Enabled Device Software Functions: Lifecycle Management and Marketing Submission Recommendations. Draft Guidance for Industry and Food and Drug Administration Staff; U.S. Food and Drug Administration: Silver Spring, MD, USA, 2025.
  108. U.S. Food and Drug Administration. Marketing Submission Recommendations for a Predetermined Change Control Plan for Artificial Intelligence-Enabled Device Software Functions: Guidance for Industry and Food and Drug Administration Staff; Food and Drug Administration: Silver Spring, MD, USA, 2024.
  109. European Union. Regulation (eu) 2026/1744 of the European Parliament and of the Council of 8 July 2026 Amending Regulations (eu) 2024/1689, (eu) 2018/1139 and (eu) 2023/1230 (Digital Omnibus on AI); European Union: Brussels, Belgium, 2026. [Google Scholar]
  110. Alreshidi, F.S.; Alsaffar, M.; Chengoden, R.; Alshammari, N.K. Fed-cl- an atrial fibrillation prediction system using ecg signals employing federated learning mechanism. Sci. Rep. 2024, 14, 21038, Correction in Sci. Rep. 2024, 14, 31550. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  111. Lekadir, K.; Frangi, A.F.; Porras, A.R.; Glocker, B.; Cintas, C.; Langlotz, C.P.; Weicken, E.; Asselbergs, F.W.; Prior, F.; Collins, G.S.; et al. Future-AI: International consensus guideline for trustworthy and deployable artificial intelligence in healthcare. BMJ 2025, 388, e081554, Correction in BMJ 2025, 388, r340. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  112. Moons, K.G.M.; Damen, J.A.A.G.; Kaul, T.; Hooft, L.; Andaur Navarro, C.; Dhiman, P.; Beam, A.; Van Calster, B.; Celi, L.; Denaxas, S.; et al. Probast+AI: An updated quality, risk of bias, and applicability assessment tool for prediction models using regression or artificial intelligence methods. BMJ 2025, 388, e082505. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  113. Liu, Y.; Wang, C.; Lu, M.; Yang, J.; Gui, J.; Zhang, S. From simple to complex scenes: Learning robust feature representations for accurate human parsing. IEEE Trans. Pattern Anal. Mach. Intell. 2024, 46, 5449–5462. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  114. Wang, S.; Wang, C.; Shi, C.; Liu, Y.; Lu, M. Mask-guided mamba fusion for drone-based visible-infrared vehicle detection. IEEE Trans. Geosci. Remote Sens. 2024, 62, 1–12. [Google Scholar] [CrossRef] [Scilit]
  115. Xu, Y.; Lu, J.; Ding, S.; Cao, D.; Hu, X.; Yang, C. An electrocardiogram multi-task benchmark with comprehensive evaluations and insightful finding. arXiv 2025. [Google Scholar] [CrossRef] [Scilit]
  116. Duan, Y.; Qiu, W. ECG-InterpBench: Benchmarking the interpretability of ECG foundation models with matched-scale sparse autoencoders. arXiv 2025. [Google Scholar] [CrossRef] [Scilit]
  117. Muneer, A.; Waqas, M.; Saad, M.B.; Showkatian, E.; Bandyopadhyay, R.; Xu, H.; Li, W.; Chang, J.Y.; Liao, Z.; Haymaker, C.; et al. From classical machine learning to emerging foundation models: Review on multimodal data integration for cancer research. Artif. Intell. Rev. 2026, 59, 119. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Article metric data becomes available approximately 24 hours after publication online.