Skip to Content
SeparationsSeparations
  • Article
  • Open Access

29 September 2026

24 Pages

Determination of Acid Herbicides in Plant Leaves Using a Modified QuEChERS Method and UHPLC-MS/MS

,
,
,
,
and
Chemistry Department, Federal University of Santa Maria (UFSM), Santa Maria 97105-900, RS, Brazil
*
Author to whom correspondence should be addressed.
This article belongs to the Section Environmental Separations

Abstract

The use of herbicides to control weeds in crops, especially in soybeans, corn, and sugarcane, is a common practice, but it poses a risk to nearby sensitive crops, since herbicide drift is common and has caused phytotoxicity, resulting in reduced crop yield. Thus, the determination of acid herbicides in plant leaves is important but challenging due to the complexity of the matrix and compound characteristics. Considering this, an analytical method was developed and validated for the determination of 22 acid herbicides in plant leaves, using a modified QuEChERS procedure and ultra-high performance liquid chromatography with tandem mass spectrometry (UHPLC-MS/MS) with a run time of 10 min. The optimized method involved the extraction of the hydrated sample with acetonitrile containing formic acid, partitioning with salts, and cleanup with graphitized carbon black. Validation presented recoveries from 71 to 118%, with RSD ≤ 19% and method limit of quantification of 5 µg kg−1 for most of the herbicides indicating satisfactory performance. The proposed method was applied to 50 plant leaf samples, 36 of which contained residues of at least one of the evaluated herbicides. The developed method is rapid and efficient and can be applied in routine analyses of acid herbicides in plant leaves.

1. Introduction

The use of herbicides has become an important strategy for weed control and maintaining agricultural productivity. However, the increased use of herbicides can affect non-target plants grown near application sites due to drift. The effects on non-target plants manifest at different times after exposure, depending on the characteristics of the compound and the plant species. While some damage is noticeable immediately after application, other effects emerge only after a certain period [1]. Drift is characterized by the movement of part of the applied product beyond the application site, unintentionally reaching unplanned areas. Vineyards are particularly susceptible to this phenomenon, and the damage can lead to reduced productivity, compromised fruit quality, and, in the most severe cases, the death of the vines. Sometimes, symptoms persist for 2 to 3 years after the incident, reducing plant vigor, promoting the occurrence of diseases, and shortening the vineyard’s lifespan [2]. Brazilian grape production has been growing and is now close to 1.8 million metric tons per year, with a cultivated area of 84,400 hectares [3]. The wine sector is characterized by growing competition among countries and economic blocs, within an increasingly dynamic business environment underpinned by production technologies [4]. Among the herbicides associated with damage, plant growth regulators, especially synthetic auxins, stand out, along with other acidic compounds. In Brazil, reports of losses and damage associated with herbicide drift have been increasing across different producing regions, highlighting the significance of the unintended dispersion of herbicides used for weed management in crops such as soybeans, corn, and sugarcane [5]. Herbicides stand out among the most widely used pesticides globally, due to their relatively low cost and high agronomic efficacy [6]. In Brazil, in 2024, herbicides stood out as the most widely used class, accounting for 52.1% of all pesticides used, with the herbicide glyphosate being the best-selling at 231,888 metric tons, 2,4-D ranking third at 60.340 metric tons, glufosinate in sixth place with 25,903 metric tons, atrazine in seventh with 24,909 metric tons, S-metolachlor in eighth with 17,441 metric tons, and clethodim in tenth with 16,394 metric tons [7]. The widespread adoption of the no-till farming system, which minimizes soil disturbance, requires the application of herbicides such as glyphosate and 2,4-D for weed control [8].
Also known as hormonal herbicides, auxin-mimicking herbicides are so named because of their structural similarity to natural plant auxins. They are one of the oldest classes of herbicides used in agriculture, with 2,4-D being the first herbicide registered for use in Brazil [9,10]. Their use is primarily directed toward controlling broadleaf dicotyledonous weeds and shrubs in grass crops and pastures, where they demonstrate high efficacy. In addition to 2,4-D, other notable herbicides in this class include dicamba, fluroxypyr, picloram, quinclorac, and triclopyr [11]. Acid herbicides constitute a class of great importance in weed management in both agricultural and non-agricultural environments, encompassing compounds from different chemical groups, such as derivatives of benzoic acid (dicamba), phenoxyacetic acid (2,4-D), propanoic acid (fluazifop), and picolinic acid (clopyralid), as well as other families, such as imidazolinones and benzothiadiazines. Their high efficacy combined with selectivity justifies their widespread use in agriculture, leading to the frequent occurrence of these compounds in the environment in the form of free acids, with a predominance of those belonging to the phenoxyacetic acid group [12].
The herbicides 2,4-D, picloram, and triclopyr are among the most widely used acid-based herbicides. 2,4-D is effective in controlling various weeds and is an important strategy for managing species that have developed resistance to glyphosate, although it poses a risk of drift and damage to sensitive crops. In addition, formulation characteristics can influence properties such as volatility and drift potential, while inappropriate environmental conditions can reduce the treatment’s efficacy [13]. Picloram is highly effective in controlling broadleaf weeds, has excellent systemic activity, and exhibits greater persistence in the soil, promoting prolonged control. However, this characteristic may increase persistence and pose a risk to subsequent crops [14,15]. Triclopyr is used primarily to control broadleaf weeds and woody species and generally exhibits lower persistence in the soil than picloram [16].
Among environmental transport processes, drift is considered one of the main challenges related to herbicide use, primarily due to the difficulty of restricting the product’s deposition exclusively to the target area. Defined as the movement of sprayed droplets outside the application area, drift is strongly influenced by droplet size and environmental conditions [17]. Data from the Secretariat of Agriculture, Livestock, and Rural Development of the State of Rio Grande do Sul, Brazil, highlight the scale of the herbicide drift problem. Of 96 samples collected in response to reports of herbicide drift, grapevines stood out, with 57 samples analyzed, accounting for approximately 59% of the cases. Damage was also recorded in crops such as pecan and olive trees, with 4 and 2 samples, respectively, as well as sorghum, strawberries, arugula, and kale. Although the herbicide 2,4-D is one of the main compounds associated with drift incidents in the state, analyses conducted since 2019 have also identified the presence of other hormonal herbicides, such as aminopyralid, fluroxypyr-meptyl, picloram, quinclorac, and triclopyr-butyl. Between August and December 2021, for example, 13 samples tested positive for quinclorac and 7 for fluroxypyr-meptyl [18]. Despite the significance of this issue, the assessment of herbicide drift still faces challenges, especially regarding the determination of residues in plant leaves. Although there are several analytical methods designed to determine pesticides in fruits and grains, few studies have focused on analyzing these compounds in leaves. Damage caused by acidic herbicides has been frequently reported, affecting the yield and quality especially of grape production [19].
The toxicological effects of herbicides depend on the dose, route, and duration of exposure. Exposure to 2,4-D can cause biochemical and physiological changes in mammals, particularly those related to liver function and oxidative balance. Recent studies report changes in antioxidant enzymes, increased lipid peroxidation, and alterations in energy and lipid metabolism. Oxidative stress is identified as one of the mechanisms involved in the hepatic toxicity of 2,4-D [20]. For triclopyr, the kidney is one of the main target organs of toxicity in mammals. Bartels et al. [21] demonstrated that the herbicide is rapidly absorbed following oral exposure and eliminated predominantly via urine, with minimal metabolism and low tissue retention.
From an analytical standpoint, the determination of acidic herbicide residues in plant leaves is challenging due to the complexity of the plant matrix and the physicochemical properties of these analytes. Among the available sample preparation procedures, the QuEChERS method and its modifications stand out for their simplicity, extraction efficiency, purity of the extracts, and adaptability to the characteristics of the matrix and the analytes [22,23]. Regarding acidic compounds, they are classified as pH-sensitive analytes, since their recovery efficiency in the QuEChERS method is directly related to their state of ionization. During the extraction/partition step, when the matrix pH exceeds the pKa value of the analyte, acidic pesticides tend to remain predominantly in the ionized form, which hinders their migration into the organic phase and results in lower recoveries. Given that the pH of agricultural matrices generally ranges from 2.5 to 7, the ionization of these compounds is common, requiring method adaptations [24]. In this context, Anastassiades et al. [25] demonstrated that several acidic pesticides, such as 2,4-D and fluazifop, exhibit marked pH dependence throughout the analytical process. Furthermore, according to Rejczak and Tuzimski [24], acidic herbicides tend to exhibit significant reductions in recovery at pH values close to 6, highlighting the direct influence of this parameter, especially due to the pKa values of the compounds. In this context, the use of pH buffers has become essential to ensure the inclusion of these analytes in the analytical scope. Among the approaches evaluated by Lehotay et al. [26], the acetate buffer, adjusted to pH 4.8, stood out for providing higher and more consistent recoveries when compared to both the unbuffered method and the citrate buffer. In addition to the buffering effect, improvements in the solid-phase dispersion (d-SPE) cleanup step included the addition of the sorbent octadecylsilane (C18) in combination with a primary-secondary amine (PSA), aiming for more efficient removal of lipids and other co-extractables, especially in matrices with higher fat content. Another advancement in the cleanup step was the reduction in pigment content in extracts from plant matrices, achieved by adding small amounts of graphitized carbon black (GCB), which has a large surface area and highly polar groups, with high potential for hydrogen bonding [27]. Rejczak and Tuzimski [24] demonstrated that the PSA sorbent may have limitations in the cleanup of matrices with high levels of carotenoids and chlorophyll, requiring the addition of small amounts of GCB to improve the removal of these pigments. However, due to GCB’s high affinity for planar compounds, some analytes may be removed from the extract, resulting in low recoveries. Since chlorophyll exhibits an even greater affinity for GCB, it is recommended that the final extract remain slightly greenish, indicating that there was no excessive retention of planar compounds during the cleaning step.
A recurring problem in the extraction of acidic analytes using the QuEChERS method is the significant loss of these analytes due to interaction with the PSA [24]. Koesukwiwat et al. [28] proposed a modified QuEChERS method using alumina combined with C18 in the d-SPE step for the extraction of phenoxy acid pesticides, such as 2,4-D, quinclorac, and picloram. Sack et al. [29] proposed an acidified QuEChERS method, without a cleanup step, for the determination of 35 acid herbicides, such as 2,4-D, dicamba, quinclorac, and imidazolinones, achieving an average recovery of 95%. Ghoniem et al. [30] developed a method for the determination of 8 acid herbicides in strawberries and green beans using citrate-based QuEChERS without a cleanup step, combined with dilution of the extract, yielding recoveries between 81 and 113% for most compounds. Similarly, Hyland and Winkler [31] employed extraction with acidified acetonitrile followed by dilution of the extract to quantify dicamba and other acid herbicides in soybean soil and foliage, achieving adequate recoveries for all analytes evaluated. Various techniques have been developed over the years for the extraction of pesticide residues from plant matrices. The literature [29,30,31,32,33,34,35,36,37,38,39,40,41] indicates that QuEChERS is among the most widely used methods for determining pesticide residues in vegetable matrices, as highlighted in Table S1.
The combination of QuEChERS with ultra-high-performance liquid chromatography coupled with tandem mass spectrometry (UHPLC-MS/MS) is an appropriate analytical strategy for the analysis of herbicides in plant leaves. Considering this, the objective of this study was to develop an analytical method based on sample preparation using modified QuEChERS and the determination of acidic herbicides in plant leaves using UHPLC-MS/MS to enable the assessment of drift occurrence.

2. Materials and Methods

2.1. Reagents and Materials

The reagents, solvents, and other materials used in this study were: anhydrous sodium acetate, purity ≥ 99% (Sigma-Aldrich, Taufkirchen, Germany); acetone, HPLC grade (Honeywell, Charlotte, NC, USA); acetonitrile, HPLC grade (Supelco, Bellefonte, PA, USA); glacial acetic acid, 100% purity (Supelco, Darmstadt, Germany); formic acid, 98–100% purity (Supelco, Espoo, Finland); purified water with a conductivity of 0.055 µS cm−1; argon 5.0, purity ≥ 99.999% and helium 6.0, purity ≥ 99.9999% (Air Liquide, São Paulo, Brazil); sodium citrate dihydrate, purity ≥ 99% (Macron Fine Chemicals, Toronto, ON, Canada); sodium citrate sesquihydrate, purity ≥ 99% (Sigma-Aldrich, Taufkirchen, Germany); sodium chloride, purity ≥ 99% (Sigma-Aldrich, San Luis, CA, USA); anhydrous magnesium sulfate, purity ≥ 99.5% (Sigma-Aldrich, Tokyo, Japan); toluene, HPLC grade (Mallinckrodt Chemicals, St. Louis, MO, USA); Extran® neutral (Merck, Rio de Janeiro, Brazil); nylon filters, 13 mm in diameter and 0.2 µm pore size and PES filters, 13 mm in diameter and 0.2 µm pore size (Agilent Technologies, Santa Clara, CA, USA); PTFE filters, 13 mm in diameter with a pore size of 0.22 µm (Chromastore, São Paulo, Brazil); PVDF filters, 13 mm in diameter with a pore size of 0.22 µm (Analítica, São Paulo, Brazil); 2 and 4 mL vials (Analítica, São Paulo, Brazil); hexane, HPLC grade (Honeywell, Charlotte, NC, USA); methanol, HPLC grade (Supelco, Bellefonte, PA, USA); 2 and 5 mL Eppendorf-type centrifuge microtubes (Axygen, Reynosa, Mexico); solid herbicide standards (LGC Standards, Wesel, Germany); Neutral alumina stationary phase, 40–160 µm (Sigma-Aldrich, Buchs, Switzerland); graphitized carbon (GCB), 120–400 mesh, octadecylsilane (C18), with 50 µm particles and Z-Sep+, with 50 µm particles (Supelco, Bellefonte, PA, USA); 15 and 50 mL polypropylene screw-cap centrifuge tubes (Sarstedt, Sarstedt, Germany); and standard laboratory glassware.

2.2. Instrumentation

The equipment used in this study included: a vortex mixer, model VX-38 (Ionlab, Araucária, Brazil); analytical balances, models ATX224R, AUW220D, AUX220, BL320H, and UX420H (Shimadzu, Kyoto, Japan); refrigerated centrifuges, model NT 825, for 15 and 50 mL tubes (Novatecnica, Piracicaba, Brazil); automatic variable-volume micropipettors (Brand, Brand, Germany); cutter-type food processor, model CR-8L (Skymsen, Brusque, Brazil); Milli-Q® water purification system, model IQ 7010 (Millipore, Molsheim, France); GC-MS system, model GCMS-QP2010 SE, equipped with an AOC-6000 automatic sampler (Shimadzu, Kyoto, Japan); UHPLC-MS/MS system (Waters, Milford, MA, USA), consisting of: ACQUITY UPLC® liquid chromatograph, equipped with a binary pump system for high-pressure gradient operation, ACQUITY UPLC® HSS T3 analytical column (100 × 2.1 mm, 1.8 µm) (Waters, Drinagh, Ireland), and a triple-quadrupole mass spectrometer, model Xevo TQ-XS, with an electrospray ionization (ESI) source and MassLynx data acquisition software, version 4.2; nitrogen generator, model NM30L-MS (Peak Scientific, Inchinnan, Scotland); air compressor, model SF2 FF (Atlas Copco, Overijse, Belgium); vacuum pump, model EV-SA30-2 (Ebara, Tokyo, Japan).

2.3. UHPLC-MS/MS Analysis

The chromatographic conditions were adapted from the study reported by Jandova et al. [12], including the gradient program and mass spectrometry parameters. Thus, an ACQUITY UPLC® HSS T3 column (100 × 2.1 mm, 1.8 µm) was used, and the mobile phase consisted of (A) water containing 0.02% formic acid and (B) methanol. A gradient injection was performed using acetonitrile at concentrations of 0.25, 0.5, 1, 2, 5, and 10 µg L−1. Next, the mobile phase used in routine laboratory analyses for negatively charged compounds, consisting of (A) water containing 5% acetonitrile and (B) acetonitrile, both containing 0.01% acetic acid, was evaluated. Comparative analyses were conducted, and this condition provided better analytical performance; it was therefore selected for the analyses. The injection volume used was 5 µL, with a total analysis time of 10 min. Chromatographic separation was performed using a column at 40 °C, with a flow rate of 0.225 mL min−1 and elution using the following gradient: 5% B from 0 to 0.25 min; 100% B at 7.75 min and held until 8.5 min; returning to 5% at 8.51 min and held until 10 min.
The operating conditions of the MS/MS system were optimized, and the following parameters were adopted: source temperature: 150 °C; capillary voltage: 3 kV; desolvation temperature: 600 °C; desolvation gas flow rate (N2): 600 L h−1; cone gas flow rate (N2): 150 L h−1; collision gas flow rate (Ar): 0.34 mL min−1; and dwell time: 0.003 to 0.120 s. The mass spectrometer operated with electrospray ionization in positive and negative modes (ESI±), using selected reaction monitoring (SRM) with two transitions for each compound. The most abundant ion, corresponding to the first transition, was selected for quantification, while the second most intense transition was used to confirm the identity of the herbicides.

2.4. Selection of Compounds of Interest, Surrogate, and Internal Standard

The acid herbicides evaluated were selected based on a literature review, with particular emphasis on the studies reported by Sack et al. [29], Saito-Shida et al. [36], and Gomes Ferreira et al. [41]. Thus, 24 compounds were selected, which are listed in Table S2, along with information on class, chemical group, purity of the solid standard, and physicochemical properties. The analytical standards used were purchased from LGC Standards (Wesel, Germany) and have a purity greater than 94.8%.
Stock solutions of the individual compounds were prepared at a concentration of 1000 mg L−1 in acetonitrile, considering the purity of the solid standards, and were stored in amber vials at temperatures below −10 °C. From these solutions, a mixture of the compounds was prepared at a concentration of 10 mg L−1 in acetonitrile, and from this mixture, the working solutions used in the chromatographic analyses and in the spike of the blank samples were prepared. Atrazine-d5, prepared in acetonitrile at a concentration of 10 mg L−1, was used as a surrogate and added at the beginning of the extraction process to monitor the overall efficiency of the analytical procedure. Triphenylphosphate was used as the internal standard (IS), added directly to the final extract to verify the performance of the analysis, without being used for quantification or recovery correction. The solution was prepared in acetonitrile at a concentration of 10 mg L−1.

2.5. Evaluation of Sample Preparation

The evaluated sample preparation procedures were proposed based on methods reported in the literature for the determination of acid herbicide residues in plant-based matrices and on work conducted in the laboratory. The evaluations were conducted using spiked blank samples of grapevine leaves, which were adopted as representative of plant leaves in general. The strategies evaluated included different extraction solvents, partition salts, cleaning sorbents, dilution factors and solvents, as well as filtration materials, based on publications by Sack et al. [29], Viera et al. [33], Hyland and Winkler [31], and Islam et al. [37]. Table S3 summarizes all the sample preparation conditions evaluated in the 27 tests conducted to determine the most effective conditions.

2.5.1. Evaluation of the Extraction and Partition Steps of the QuEChERS Method

The initial tests (T1, T2, and T3), designed to evaluate the extraction and partitioning steps, were conducted in triplicate with 3 g of sample, using three variations of the QuEChERS method: original acidified [25], acetate [42], and acidified citrate [28]. Given the nature of the herbicides, the possibility of omitting the cleaning step was also investigated, in accordance with approaches described by Sack et al. [29], Ghoniem et al. [30], and Li et al. [38]. Initially, the sample was hydrated, followed by manual shaking for 1 min. Next, the extraction step was performed. After adding the partition salts, the sample was again shaken manually for 1 min and then centrifuged at 4850× g for 8 min (5 °C). Finally, the extracts obtained were diluted 1:10 (v/v) in the mobile phase, filtered using a PVDF filter (0.22 μm), and analyzed by UHPLC-MS/MS. The assays were conducted at a concentration of 2 µg L−1, equivalent to 66.6 µg kg−1 in the sample, considering the dilution factor applied.
Tests T4 through T6 were performed in triplicate to evaluate the effect of the extraction solvent. Thus, in these experiments, acetonitrile acidified with 1 and 5% (v/v) formic acid (T4 and T5, respectively) was used, as well as methanol acidified with 1% (v/v) formic acid (T6). It should be noted that, in T6, the hydration and partitioning steps were not performed, since phase separation does not occur with methanol, thereby precluding the salting-out effect characteristic of the QuEChERS method. Based on the results obtained, the most suitable extraction solvent was determined, and the need for the extract cleanup step was reevaluated.

2.5.2. Evaluation of the Extraction Cleanup and Dilution Steps

Tests T7 through T12, designed to evaluate the extract cleanup step, were conducted in triplicate by applying different sorbents in the dispersive solid phase extraction (d-SPE) mode, as presented in Table S3. The selection of materials considered the conditions reported in the literature for the cleanup of extracts from plant matrices [28,33,37,41], as well as the availability of sorbents in the laboratory.
The efficiency of the cleanup step was evaluated in terms of the removal of co-extractables, especially pigments, through visual inspection of the extracts, and in terms of analyte recovery, determined from spiking assays at the level of 2 μg L−1, corresponding to 13.3 μg kg−1 in the sample. In these assays, the extracts were first diluted 1:1 (v/v) in the mobile phase and then filtered through a PVDF membrane (0.22 μm). Both criteria were considered in selecting the most appropriate cleaning condition. Subsequently, tests T13 through T21 were conducted in triplicate based on the condition selected from the previous tests, evaluating different amounts of GCB (40, 50, and 60 mg per 2 mL of supernatant) and dilution factors (2, 3, and 5 times), as presented in Table S3. The efficiency of these conditions was evaluated using spiking at levels of 13.3, 20, and 33.3 μg kg−1 in the sample, obtained based on the different dilution factors applied, while maintaining a constant concentration of 2 μg L−1 in the equipment.
In addition, the efficiency of co-extract removal was evaluated by analyzing the blank extract of the matrix using a full-scan mode GC-MS. The chromatographic profile corresponding to the cleaning condition previously selected as the most appropriate was compared to that of the blank extract without the cleaning step. After defining the extraction, partition, and cleaning conditions, as well as the dilution factor, established in accordance with test T14, the effect of the solvent used to dilute the extracts was investigated by comparing the use of ultrapure water (T22) and mobile phase (T23). The assays were performed at a concentration of 2 μg L−1, equivalent to 20 μg kg−1 in the sample, considering the prior dilution of the extracts in a 1:3 (v/v) ratio. The evaluation was based on a comparison of the analyte areas and the shape of the chromatographic peaks, with the selection criterion being the condition that provided the highest instrumental response and the best chromatographic profile.

2.5.3. Evaluation of the Extract Filtration Step

Finally, tests T24 through T27 evaluated the effect of different types of syringe filters on the extract filtration step. Filters made of polyvinylidene fluoride (PVDF) (T24), polytetrafluoroethylene (PTFE) (T25), nylon (T26), and polyethersulfone (PES) (T27) were investigated. The assays were conducted at a concentration of 2 μg L−1, using as the selection criterion the response obtained for the addition of the standard to the spiked blank matrix before and after the filtration step, both of which were diluted 1:3 (v/v) in ultrapure water.

2.6. Method Validation

The validation of the method proposed in this study was conducted based on the guidelines established by SANTE [43] evaluating the parameters of selectivity, linearity, matrix effect, accuracy (in terms of recovery), precision (in terms of repeatability and intermediate precision), limit of quantification (LOQ), and limit of detection (LOD). The matrix effect was calculated by comparing the slopes of the curves prepared in acetonitrile and in the blank matrix extract, as described by Vicari et al. [44], with values greater than ±20% considered significant. The acceptance criteria adopted for recovery (Rec, %) ranged from 70 to 120% with RSD ≤ 20%. LOQ values were established based on spiking tests and were defined as the lowest spiking level that yielded acceptable recovery (70–120%) and an RSD ≤ 20%. The LOD value was calculated from the LOQ value by dividing it by 3.33.

2.7. Sample Collection and Processing

Vine leaves, representing plant leaves, obtained from an organic farm were used as blank samples. Initially, the collected material was analyzed by UHPLC-MS/MS to verify the absence of residues from the investigated herbicides, confirming its suitability as a blank matrix. The whole leaves, including the leaf blade and petiole, were processed by homogenization with dry ice in a 2:1 ratio using a food processor. The material was then placed in polypropylene vials, which were kept open until the CO2 had sublimated. Subsequently, the samples were stored in a freezer at temperatures below −10 °C until analysis.
The developed method was applied to the analysis of 50 samples of leaves from 15 different plants collected in several locations in Brazil. Approximately 300 g of sample was collected, processed, and stored in a freezer.

3. Results

3.1. LC-MS/MS Established Conditions

Initially, chromatographic optimization tests were performed based on the analytical conditions most frequently used in the laboratory. For the analyses, an ACQUITY UPLC® HSS T3 column was used, consisting of high-strength silica (HSS) and a low-density C18 stationary phase. To select the mobile phase, the condition proposed by Jandova et al. [12] was tested, consisting of (A) water containing 0.02% formic acid and (B) methanol. Next, the mobile phase used in routine analyses for negatively charged compounds was evaluated; it consisted of (A) water with 5% (v/v) acetonitrile and (B) acetonitrile, both containing 0.01% acetic acid. Figure S1 shows the chromatograms of the herbicide bromacil obtained under the two evaluated conditions, with the aim of comparing the performance of the mobile phases in terms of chromatographic profile and analytical response of the compound. The analyses were performed by UHPLC-MS/MS using a standard solution prepared in acetonitrile at a final concentration of 2 µg L−1. Based on the results obtained, which showed better peak definition and higher signal intensity, the mobile phase consisting of (A) water with 5% acetonitrile and (B) acetonitrile, both containing 0.01% acetic acid, was selected for the subsequent steps of the method. This composition provided adequate analytical signals, high resolution, and good peak shape for the compounds under study.
The UHPLC-MS/MS system was operated in selected reaction monitoring (SRM) mode, and one precursor ion and two product ions were selected for each analyte of interest. The most abundant ion, corresponding to the first transition, was used for quantification, while the second transition was used for identification, ensuring the reliability of the results. The application of this approach enabled the determination of 22 acid herbicides in plant leaves using a modified QuEChERS method, with adequate chromatographic separation and an analysis time of 10 min. The mass spectrometer operating conditions are described in Table S4.
Figure S2 shows the total ion chromatogram (TIC) of all herbicides evaluated in this study, obtained by UHPLC-MS/MS from a standard solution prepared in the blank matrix of grapevine leaves at a concentration of 10 µg L−1.

3.2. Evaluation of the Extraction and Partition Steps

Due to the low concentration of the analytes, their distinct chemical properties, and the complexity of the matrix, it became necessary to develop a preliminary sample preparation step that was simple, efficient, and capable of adequately extracting the compounds of interest [45]. The proposed method sought to optimize extraction conditions by considering the choice of solvent, partition salts, and cleaning solvents, as well as the dilution factor and solvent, with the aim of maximizing analyte recovery and minimizing matrix interference.
Initially, three variations of the QuEChERS method, including the original acidified method (T1), the acetate method (T2), and the acidified citrate method (T3), were evaluated for their ability to recover the compounds of interest, as illustrated in Figure 1, which shows a graph of the recoveries obtained. In these assays, the possibility of omitting the washing step was also investigated. Considering that plant leaves constitute a matrix with low water content, a smaller sample volume was used, and water was added to improve homogeneity and ensure extraction efficiency.
Figure 1. Recoveries (n = 3) obtained from the three evaluated variations of the QuEChERS method, including acidified original (T1), acetate (T2), and acidified citrate (T3). The yellow line indicates the acceptable limits, and the green line indicates the 100%.
Through spiking assays, it was found that, among the 24 pesticides evaluated, T1 and T3 performed best, with 22 analytes within the acceptable range, while T2 yielded 20 compounds with adequate recoveries. In the literature, the original acidified and citrate QuEChERS methods stand out as the most widely used for determining residues of acidic herbicides in matrices of similar composition, as reported by Sack et al. [29] and Ghoniem et al. [30], who used the acidified and buffered methods to determine 35 and 8 acidic herbicides, respectively. Thus, there is agreement with the results observed in this study.
The differences in recoveries between the methods are mainly related to the influence of pH on the chemical equilibrium of the compounds in the extraction solution. In general, most compounds are more stable at acidic pH; however, some may have low recoveries because they remain protonated and are more soluble in the aqueous phase, making their recovery during the partition step difficult [45]. Thus, in acidified methods, acidic compounds with lower pKa values remain predominantly in the neutral form, which increases their affinity for the organic phase and promotes their extraction [42,46].
In this context, acidification of the medium also improves the recovery of analytes such as picloram, whose extraction is favored at low pH values, consistent with what was observed in T1 and T3. On the other hand, in the acetate QuEChERS method (T2), which buffers at a higher pH, compounds with this characteristic remain partially ionized, which reduces their affinity for the organic phase and, consequently, decreases extraction efficiency [25,47]. Despite the good overall performance, it is important to note that aminopyralid and clopyralid were not recovered in any of the three variations evaluated. The difficulties associated with the analysis of these compounds are diverse and difficult to control. Among the main factors influencing the degradation rate are pH, solvent type, light exposure, matrix components, temperature, water content, and analyte concentration [45]. Furthermore, the very nature of the matrix can constitute a limitation to the recovery of these analytes. Due to their high polarity and acidic nature, aminopyralid and clopyralid tend to interact with the plant matrix, which hinders their transfer to the organic phase. In matrices with higher water content and lower structural complexity, the recovery of these analytes is enhanced, as demonstrated by Tian et al. [48], who used identical experimental conditions. On the other hand, more complex matrices, such as grapevine leaves, which are rich in phenolic compounds, chlorophyll, and lignocellulosic material, may promote the retention of these compounds within the matrix, thereby limiting their extraction; however, no significant differences were observed between the versions evaluated in T1 and T3. Therefore, the original acidified QuEChERS method (T1) was selected as the most appropriate for the subsequent stages of the evaluation. In addition to providing satisfactory recoveries for most compounds (22), this method is unbuffered, making it simpler, more economical, faster, and generating less waste compared to the other variations. Next, two acetonitrile-based extraction conditions (T4 and T5) were evaluated, in which acetonitrile acidified with 1 and 5% (v/v) formic acid, respectively, was used. Concurrently, test T6 was conducted as a complementary approach, using methanol acidified with 1% (v/v) formic acid as the extraction solvent. In this case, the hydration and partition steps were not performed, since T6 was not a variation of the QuEChERS method but rather an exploratory assessment of methanol’s ability to facilitate the extraction of more polar analytes.
Figure 2 shows that the three conditions evaluated yielded satisfactory analytical performance, with recoveries ranging from 70 to 120% and relative standard deviation (RSD) values ≤20%. Although the acceptance criteria were met, a trend toward lower recoveries was observed when acidified methanol (T6) was used as the solvent. In fact, several studies report advantages of using methanol for the extraction of certain analytes compared to acetonitrile [49,50]; however, this behavior was not reflected in higher recoveries for the set of analytes evaluated. Thus, due to acetonitrile’s more consistent performance, it was selected as the extraction solvent for the subsequent steps of the procedure. The choice of acetonitrile allows for the extraction of a wide range of pesticides with different polarities, and when acidified, it promotes the stability of compounds susceptible to degradation, yielding more satisfactory recoveries. Furthermore, acidifying acetonitrile helps increase the extraction efficiency of acidic compounds, such as phenoxy acid herbicides, as reported by de Souza [51].
Figure 2. Graph showing the recoveries (n = 3) obtained in the extraction using acetonitrile acidified with 1% (v/v) formic acid (T4), acetonitrile acidified with 5% (v/v) formic acid (T5), and methanol acidified with 1% (v/v) formic acid (T6). The yellow line indicates the acceptable limits, and the green line indicates the 100%.
Although both solvent compositions (T4 and T5) demonstrated similar performance, with the compounds falling within the acceptable recovery range, we opted to use acetonitrile acidified with 1% (v/v) formic acid (T4). This condition provided analytical performance equivalent to that obtained with the higher acid concentration, but with lower consumption of this toxic and corrosive reagent, in addition to contributing to a reduction in operating costs.

3.3. Evaluation of the Extract Cleanup and Dilution Steps

Given the influence of the dilution factor on the limit of quantification (LOQ), it was decided to include a cleaning step to reduce this factor. Although this step may result in the loss of some compounds, in addition to increasing the time and cost of the process, it is one of the most recommended alternatives for minimizing the matrix effect, which can lead to false positives resulting from the coelution of impurities with the analyte, as well as damage to the chromatographic system [22].
Thus, after defining the extraction and partition procedures, different sorbents were evaluated in the d-SPE cleanup step. Due to the wide availability of sorbents at the laboratory, those most frequently described in the literature were selected, as well as materials with distinct compositions, with the aim of promoting the efficient removal of matrix co-extractables without compromising the recovery of the compounds. Table 1 presents the recovery percentages and RSD values obtained in tests T7 to T12.
Table 1. Recovery percentages and RSD values obtained in tests T7 to T12 (n = 3).
Table 1 shows that the sorbents evaluated in T8 and T11 yielded the same number of compounds within the acceptable criteria, standing out from the other tests, followed by T9, T10, T7, and T12, respectively. However, as shown in Figure 3, in which the extracts were diluted 1:1 (v/v) in the mobile phase prior to injection, visual evaluation indicates that T8 exhibits the most appropriate coloration among the conditions studied. It is observed that, although T11 (50 mg of Z-Sep+) provided the best recovery values, it demonstrated one of the lowest efficiencies in removing pigments from the matrix. According to Rejczak and Tuzimski [24], Z-Sep+ consists of a silica-based sorbent coated with zirconia and octadecylsilane (C18), with a high capacity for removing fats and pigments when compared to traditional sorbents, such as PSA and C18. However, one must consider the possibility of retention of compounds with acid-base properties, a characteristic of the analytes under study. Thus, it was decided not to conduct additional experiments with larger amounts of Z-Sep+.
Figure 3. Extracts obtained in tests T7 through T12 after 1:1 (v/v) dilution in the mobile phase for visual assessment of the cleaning step efficiency.
Plants with high chlorophyll content present specific challenges in the analysis of pesticide residues due to the presence of interferents that can compromise the method’s analytical performance and affect the chromatographic system [39]. In this context, carbon-based sorbents, such as GCB, are widely used in the cleanup step for samples rich in carotenoids and chlorophyll. Thus, GCB was evaluated under different conditions, including T7 (20 mg), T8 (40 mg), T9 (20 mg of GCB + 20 μL of toluene), and T10 (50 mg of C18 + 20 mg of GCB). Although GCB is effective at removing pigments, its strong adsorption of planar compounds can lead to analyte losses and, consequently, low recoveries [41]. For this reason, in T9, the addition of toluene was investigated to enhance the recovery of compounds that might be retained by this sorbent. However, the results from T7, which used the same amount of GCB, indicated no significant retention of analytes, as well as unsatisfactory pigment removal, explaining the similarity in recoveries observed in T9. In T10, the combination of C18 and GCB also did not result in significant improvements in the cleanup of the extract, possibly due to the action of C18 in removing nonpolar compounds, such as fats and waxes.
Regarding T12 (200 mg of neutral alumina), unsatisfactory recoveries were observed for imidazolinone-class herbicides, namely imazamox, imazapic, imazapyr, imazaquin, and imazethapyr. Similar behavior was also reported by Martins et al. [52], which can be attributed to the retention of these compounds by neutral alumina. In general, amino-group- and alumina-based sorbents are effective in removing organic acids, sugars, and pigments; however, they can cause significant losses of acidic analytes during the cleanup step [24].
On the other hand, herbicides belonging to the phenoxy acid group showed satisfactory recoveries when 200 mg of neutral alumina was used, indicating that the amount of sorbent employed was sufficient to remove interferents from the matrix without causing significant retention of these analytes. Koesukwiwat et al. [28] also observed similar behavior for compounds such as picloram and clopyralid when reducing the amount of neutral alumina from 250 to 100 mg (1 mL of extract). According to the authors, smaller amounts of this sorbent can minimize the adsorption of phenoxy acids and, consequently, enhance their recovery.
The efficiency in removing co-extractives was also evaluated by calculating the matrix effect, the data for which are presented in Figure 4. The condition evaluated at T10 (50 mg of C18 + 20 mg of GCB) showed the lowest matrix effect values, with 14 analytes within the acceptable range (±20%), although it did not result in the best pigment removal. This behavior can be attributed to the nature of C18, which is widely used in the cleanup of matrices with higher lipid content due to its ability to remove nonpolar interferents, such as fatty substances [53,54].
Figure 4. Matrix effect obtained in tests T7 through T12 for evaluating the efficiency of co-extract removal.
Subsequently, the conditions investigated in T8 (40 mg of GCB) and T11 (50 mg of Z-Sep+), both of which had 11 compounds within acceptable limits, stood out. Despite this similarity, as discussed earlier, T11 exhibited limitations in pigment removal, while T8 adequately balanced low matrix effects with better visual characteristics of the extract, in addition to more consistent recovery and RSD.
On the other hand, T7 (20 mg of GCB) and T9 (20 mg of GCB + 20 μL of toluene), which used smaller amounts of GCB, performed worse, as evidenced by the lower number of compounds (10) within the ideal range and the greater dispersion of matrix effect values, indicating lower efficiency in the removal of co-extractives. Furthermore, T12 (200 mg of neutral alumina) exhibited a higher proportion of compounds (11) with an intermediate matrix effect (±20 to ±50%) and a lower number (9) with a mild matrix effect (±20%), indicating inferior performance compared to the other conditions.
Finally, it is concluded that T8 (40 mg of GCB) performed best among the evaluated conditions, meeting the established criteria for recovery and RSD, in addition to promoting more efficient pigment removal. By comprehensively considering the matrix effect, recovery values, RSD, and the visual appearance of the extracts, T8 was identified as the most suitable cleaning condition among those tested. Furthermore, it is observed that satisfactory recovery and RSD values are not necessarily associated with greater efficiency in pigment removal or a reduction in the matrix effect, which reinforces the importance of evaluating these parameters together.
Based on the selected condition, additional tests (T13 through T21) were conducted to determine whether increasing the amount of GCB could lead to even more efficient removal of co-extractives. Therefore, increasing amounts of GCB (40, 50, and 60 mg) and different dilution factors (2, 3, and 5 times) were evaluated to obtain extracts more suitable for injection into the UHPLC-MS/MS system, thereby minimizing the introduction of co-extractives into the equipment. Table 2 presents the results obtained.
Table 2. Recovery percentages and RSD values obtained in tests T13 through T21 (n = 3).
The data in Table 2 indicate that increasing the amount of GCB resulted in lower recoveries of the compounds imazaquin, quinclorac, and quizalofop-P-ethyl, which may be related to the increased interaction of these analytes with the sorbent. According to Saito-Shida et al. [36], hydrophobic interactions between GCB and the aromatic structures of the analytes may promote their adsorption to the sorbent. Similar behavior was reported by Jin et al. [39], who observed a marked reduction in the recovery of quizalofop and four other aromatic compounds as the amount of GCB increased. Based on these data, it is evident that, to ensure adequate recoveries for all analytes of interest, it is necessary to maintain, in the subsequent steps, the cleaning condition consisting of 300 mg of MgSO4 and 40 mg of GCB (T13, T14, and T15). Thus, the evaluation will now focus on investigating different dilution factors for the final extract, with the aim of minimizing the introduction of co-extractives into the system and facilitating the attainment of adequate chromatographic profiles.
Different extract/mobile phase dilution ratios were evaluated at 1:1 (v/v) (2×), 1:3 (v/v) (3×), and 1:5 (v/v) (5×), as well as the recovery of the compounds of interest. Table 2 shows that there were no significant differences in recovery and RSD among the dilution factors evaluated. Furthermore, Figure S3 demonstrates that the chromatographic peaks maintained similar shapes across the tested conditions, with no relevant differences, as observed for the compounds 2,4,5-T and triclopyr.
Given this, a 3× dilution was adopted, as it strikes a balance between reducing the introduced matrix load and achieving lower limits of quantification compared to a 5× dilution. Figure 5 allows for a visual assessment of the extracts obtained in tests T13 through T21, highlighting the combined effect of the amount of GCB and the dilution factors on the color of the extracts, consistent with the results observed in the other analyses.
Figure 5. Extracts obtained in tests T13 through T21 for visual assessment of the efficiency of the cleaning and dilution steps. The green circle indicates the condition selected for the proposed method.
In addition, the presence of co-extractives in the blank matrix extract was assessed by gas chromatography with mass spectrometry (GC-MS), operating in full-scan mode. A comparison was made between the extract without a cleaning step and the extract subjected to the condition containing 300 mg of MgSO4 and 40 mg of GCB, which had been previously selected for its superior performance in earlier experiments. It can be observed that the cleanup step was effective in reducing the co-extractives present in the crude extract. Thus, both the monitoring of acidic herbicides by UHPLC-MS/MS and the comparative analysis of the chromatograms obtained in full-scan mode by GC-MS demonstrate that the use of 40 mg of GCB in the d-SPE step provides efficient cleanup of the extracts. Consequently, the conditions established in assay T14 were selected for the cleanup and dilution steps of the proposed procedure. After defining the extraction, partition, and cleanup conditions, as well as the dilution factor, the influence of the solvent used for diluting the extracts was evaluated by comparing the use of ultrapure water (T22) and mobile phase (T23). Both tests yielded recoveries within the established acceptance criteria. However, differences in chromatographic performance were observed, particularly regarding peak area and shape. The compounds most affected were bromacil, imazamox, imazapyr, and picloram. To illustrate these differences, the chromatograms of imazamox and imazapyr are shown in Figure S4.
According to Snyder et al. [55], the shape of chromatographic peaks is influenced by the solvent used to dilute the extracts. Thus, the injection solvent must be compatible with the initial conditions of the mobile phase, since differences in elution strength can affect the behavior of the analytes at the beginning of the column. When the injection solvent is stronger than the initial mobile phase, the analytes can be transported more rapidly through the column, reducing their initial retention and promoting peak broadening, which can result in wider and asymmetric peaks. On the other hand, a solvent with lower elution strength promotes the concentration of analytes at the column inlet, leading to narrower and more symmetrical peaks. In this regard, the better peak shape observed in the extracts diluted in ultrapure water (T22) is related to the lower elution strength of this solvent compared to the initial composition of the mobile phase, consisting of 95% A (aqueous) and 5% B (organic). Thus, ultrapure water has a composition closer to the initial condition and lower elution strength, favoring the concentration of analytes at the beginning of the column with the formation of more suitable peaks. In contrast, using the mobile phase as the dilution solvent (T23) was associated, for some analytes, with differences in the area and shape of the chromatographic peaks. Although both conditions met the recovery criteria, dilution with ultrapure water (T22) generally provided better chromatographic performance, especially regarding peak shape. Considering the recovery values, chromatographic peak areas, and the quality of the signals obtained, T22 was determined to be the most suitable method for diluting the extracts, as it provided the most satisfactory analytical performance across the evaluated parameters.

3.4. Results of the Evaluation of the Extract Filtration Step

Extract filtration is one of the final steps in sample preparation for UHPLC-MS/MS analysis and is essential for removing particles and reducing the risk of chromatographic system clogging. However, this procedure can cause retention of analytes, compromising their recovery in the resulting solutions [56]. In this context, different syringe filter materials were evaluated for their influence on the filtration of extracts, including polyvinylidene fluoride (PVDF) (T24), polytetrafluoroethylene (PTFE) (T25), nylon (T26), and polyethersulfone (PES) (T27). The recovery of analytes after filtration were evaluated comparing the areas obtained from the addition of the standard to the matrix before and after the filtration step (Table 3). The comparison between these conditions allowed us to evaluate the influence of the material composition on the recovery of herbicides and to identify possible losses associated with the filtration step. In general, it was observed that the nature of the membrane influenced the recovery of certain herbicides, indicating the occurrence of interactions between the analytes and the filtration materials.
Table 3. Recovery percentages and RSD values obtained in tests T24 through T27.
Table 3 shows that the herbicides fluazifop-P-butyl, florpyrauxifen-benzyl, haloxyfop-P-methyl, quizalofop-P-ethyl, and triclopyr-butyl were most affected by the polymeric membrane used. For these compounds, the recoveries obtained with PTFE and nylon remained close to 100%, while more significant reductions were observed with PES (21–55%) and, to a lesser extent, with PVDF (55–94%). PES is an aromatic polymer whose monomeric structure consists of three main functional groups: aryl, sulfone, and ether. Although none of these sites are ionizable, the ether and sulfone groups can form intermolecular interactions, such as dipole–dipole interactions and hydrogen bonds, with the carboxylic groups found in aryloxyphenoxypropionate herbicides [57]. Furthermore, the aromatic structures of these compounds may promote interactions with the aryl regions of the polymer, favoring the retention of the herbicides in the membrane [58]. Thus, the low recovery of aryloxyphenoxypropionate herbicides may be related to the combination of these interactions. In the case of florpyrauxifen-benzyl and triclopyr-butyl, the lower recovery may be related both to the affinity for the aromatic regions of PES and to the ability of the oxygen-containing groups of the analytes to form dipole–dipole interactions and hydrogen bonds with the ether and sulfone groups of the polymer.
PVDF exhibited a similar trend, albeit to a lesser extent, indicating that the more hydrophobic nature of the esterified compounds may also contribute to the retention of these analytes on the membrane, which explains the lesser influence of this material. Furthermore, the lower recovery of fluazifop-P-butyl and florpyrauxifen-benzyl on PVDF can be attributed to the membrane’s hydrophobic nature, which favors interactions with the aromatic and hydrophobic regions of these analytes, promoting greater retention in the polymeric material [59]. PTFE, known for its more inert behavior, and nylon exhibited similar behaviors, with a smaller reduction in area after filtration compared to the other materials evaluated. Although nylon has the highest number of interaction sites among the four types of polymeric membranes evaluated, it generally showed recoveries close to 100%, indicating low retention of the herbicides under the conditions used [58]. Thus, considering nylon’s satisfactory performance in terms of analyte recovery and its lower cost compared to PTFE, this filter was selected as the most suitable for method validation.

3.5. Validation of the Proposed Method

The proposed QuEChERS method was developed, validated, and applied to the preparation of plant leaf samples for the determination of acid herbicides. At the beginning of the validation stage, the compounds aminopyralid and clopyralid were excluded from the scope due to the absence of an adequate analytical signal from the very first assays performed. Thus, the method was validated for 22 compounds, as described in Figure 6. The validation of the method for determining acid herbicides was conducted based on the guidelines established by SANTE [43]. To evaluate the analytical parameters, solutions prepared in acetonitrile were used, along with the extract obtained from the blank matrix of grapevine leaves, allowing for the assessment of potential matrix interferences.
Figure 6. Procedure for the validated QuEChERS method for the determination of acid herbicides in plant leaves by UHPLC-MS/MS.
The validated method consists of weighing 3 g of plant leaves, followed by the addition of 10 mL of ultrapure water and manual shaking for 1 min. Next, 10 mL of 1% (v/v) formic acid in acetonitrile is added, followed by another 1 min of manual shaking. For the partition step, 4 g of MgSO4 and 1 g of NaCl are added, followed by manual shaking for 1 min. Subsequently, the samples are centrifuged for 8 min at 4850× g and 5 °C.
In the extract cleanup step, a 2 mL aliquot of the supernatant is transferred to a tube containing 300 mg of MgSO4 and 40 mg of GCB. The mixture is shaken manually for 1 min and then centrifuged for 8 min at 4680× g and 5 °C. Next, the obtained extracts are diluted 1:3 (v/v) in ultrapure water and filtered using nylon filters (0.2 µm). Finally, analysis is performed by UHPLC-MS/MS. Using the developed procedure, the analytical performance parameters for the 22 selected acid herbicides were evaluated. Validation included the criteria of selectivity, linearity, matrix effect, limit of detection (LOD), limit of quantification (LOQ), accuracy, and precision, assessed in terms of repeatability and intermediate precision.
The selectivity of the method was evaluated by comparing the chromatograms of the matrix blank, the reagent blank, and the matrix blank spiked at the lowest concentration level (5 µg kg−1). No interferents were observed in the retention times of the selected compounds, indicating the absence of interference from the matrix and reagents in the determination of the analytes.
The linearity of the method was evaluated based on calibration curves prepared in the matrix (n = 3), considering seven concentration levels: 0.5, 1, 2, 2.5, 5, 7.5, and 10 µg L−1. The adequacy of the linear fit was verified using the coefficient of determination (r2), obtained by linear regression of the calibration curves. For the compounds evaluated, values of r2 ≥ 0.99 were observed, meeting the established criterion for linearity, as shown in Table 4. Based on this, a working range of 0.5 to 10 µg L−1 was defined.
Table 4. Parameters evaluated in the analytical validation, including limit of quantification (LOQ), limit of detection (LOD), linearity (r2), accuracy (recovery), precision (repeatability and intermediate precision), and matrix effect.
The matrix effect (ME) was evaluated by comparing the slopes of the calibration curves prepared in the solvent (n = 3) and in the blank matrix extract (n = 3), according to Equation 4, considering the seven established concentration levels: 0.5, 1, 2, 2.5, 5, 7.5, and 10 µg L−1. Matrix effect values between −20% and 20% are considered acceptable, indicating a negligible matrix effect and allowing, in this case, the preparation of calibration curves in the solvent. Among the 22 compounds evaluated, 6 had matrix effect values below −20%, while 1 exhibited a value above 20%, as shown in Table 4. The negative values obtained indicate suppression of the chromatographic signal. In many cases, this behavior is associated with the presence of co-eluted compounds from the matrix, which compete with the analytes during the ionization process, favoring molecules that ionize more readily and are present at higher concentrations. As a result, the signal intensity of the analytes is reduced [60]. An intensified chromatographic signal is related to the presence of a greater amount of co-extractables in the organic phase, eluted at retention times close to or coinciding with those of the analytes of interest, which can lead to an overestimation of concentrations. Given this, it was decided to prepare the calibration curves using the blank extract of the matrix.
The limit of quantification (LOQ) for the method was established based on recovery tests and defined as the lowest spike level that exhibited acceptable accuracy and precision [43]. The limit of detection (LOD) was calculated based on the LOQ, using the ratio LOQ/3.3. Table 4 presents the LOQ and LOD values for the method obtained from recovery tests. The LOQ was 5 and 10 µg kg−1 for 19 and 3 compounds, respectively, with the corresponding LOD values of 1.5 and 3 µg kg−1 for 19 and 3 compounds, respectively.
The accuracy, in terms of recovery, and precision of the method, evaluated using recovery tests on spiked blank samples at four concentration levels (5, 10, 25, and 50 µg kg−1) in 7 replicates, presented recovery values from 71 to 118% that are considered acceptable, while precision presented RSD ≤ 19%. According to Table 4, of the 22 herbicides evaluated, 19 met the established recovery range even at the lowest spike level (5 µg kg−1), while 3 compounds met the acceptance criterion starting at the 10 µg kg−1 level. The attainment of adequate values at the evaluated levels indicates that the method enabled the determination of the analytes with satisfactory accuracy and precision under repeatability and intermediate precision assay.

3.6. Application of the Validated Method

The results of the analysis of 50 samples of leaves from 15 different plants collected in several locations in Brazil are presented in Table S5. From the total samples, 36 samples presented quantified concentrations of one to two herbicides, with exception of a rice leaves sample that presented 6 herbicides. In total, 11 herbicides were quantified in the samples. The most frequent herbicides were 2,4-D, fluroxypyr and picloram present in 18, 8 and 7 samples, respectively. Some herbicides were present in very high concentrations.
Although it is used on various agricultural crops, 2,4-D is not employed in grapevine management; thus, applications in nearby areas may have caused the observed damage due to drift. In Brazil, its use is permitted on rice, corn, soybean, and wheat crops. Ribeiro et al. [61] reported damage to grapevines associated with 2,4-D drift, reinforcing this possibility of exposure. Figure S5 shows a comparative chromatogram between the analytical signal of the 2,4-D herbicide in the sample and the method’s LOQ. Fluroxypyr is a selective, systemic herbicide recommended in Brazil for pastures, soybeans, corn, cotton, sorghum, pearl millet, sugarcane, and wheat. Picloram is a systemic herbicide used primarily to control broadleaf weeds, including herbaceous, shrubby, and woody species. In Brazil, its use is approved for rice, sugarcane, wheat, and pasture crops [15]. The presence of herbicide residues on plant leaves highlights the importance of monitoring these compounds, especially given the impacts of drift on fruticulture and cereals production.

4. Conclusions

The analytical method developed proved suitable for the determination of acid herbicides in plant leaves using modified QuEChERS and UHPLC-MS/MS. The modifications made allowed for the optimization of the conditions employed in the extraction, partitioning, cleanup, dilution, and filtration steps of the extracts. The cleanup step, combined with the dilution of the extracts in a 1:3 (v/v) ratio with water, reduced pigment levels while yielding an adequate analytical signal, thereby helping to preserve the chromatographic system. Method validation was conducted in accordance with the validation parameters established by the SANTE guidelines [43]. Of the 24 pesticides initially evaluated, 22 met the adopted acceptance criteria, with adequate linearity, accuracy and precision. The limits of quantification (LOQ) obtained ranged from 0.005 to 0.01 mg kg−1, demonstrating the method’s suitability for the intended purpose. Application to plant leaf samples revealed the occurrence of acid herbicides reinforcing the importance of the proposed method for monitoring programs to confirm the occurrence of herbicide drift, supporting mitigation initiatives to avoid negative impacts in the production of food.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/separations13100274/s1, Figure S1. Chromatograms of the bromacil compound (2 µg L−1) obtained by UHPLC-MS/MS for evaluation of the mobile phases: (a) water containing 0.02% formic acid (A) and methanol (B); and (b) water containing 5% acetonitrile (A) and acetonitrile (B), both containing 0.01% acetic acid; Figure S2. Total ion chromatogram obtained by UHPLC-MS/MS from a standard solution prepared in the blank matrix of grapevine leaves at a concentration of 10 µg L−1; Figure S3. Chromatograms obtained by UHPLC-MS/MS for the compounds (a) 2,4,5-T and (b) triclopyr, from a standard solution prepared in the blank matrix of grapevine leaves at a concentration of 2 µg L−1, considering dilution factors of 2×, 3×, and 5×; Figure S4. Chromatograms obtained by UHPLC-MS/MS for the compounds (a) imazamox and (b) imazapyr, from a standard solution prepared in the blank matrix of grapevine leaves at a concentration of 2 µg L−1, to evaluate dilution in ultrapure water and the mobile phase; Figure S5. Comparative chromatogram between sample A18, containing 2,4-D (0.016 mg kg−1), and the method’s LOQ (0.005 mg kg−1); Table S1. Review of sample preparation methods used for the determination of acid herbicide residues in plant matrices; Table S2. List of herbicides under study, with information on chemical groups, purity of the solid standard, and physicochemical properties [62,63]; Table S3. Summary of the sample preparation conditions evaluated; Table S4. UHPLC-MS/MS analysis parameters, with their respective retention times (tR), ionization modes, capillary voltages (CV), selected reaction monitoring (SRM) transitions, and collision energies (CE); Table S5. Results of the analysis of 50 samples of leaves from 15 different plants collected in several locations in Brazil.

Author Contributions

Conceptualization, R.Z., O.D.P. and D.D.P.; methodology, D.D.P., C.F.Z. and L.D.D.S.; validation, D.D.P., D.M. and L.D.D.S.; formal analysis, D.D.P. and D.M.; writing—original draft preparation, D.D.P. and L.D.D.S.; writing—review and editing, R.Z.; O.D.P.; visualization, D.D.P., C.F.Z. and D.M.; supervision, O.D.P.; project administration, R.Z.; funding acquisition, R.Z. and O.D.P. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)/INCT-ALIM number 406760/2022-5.

Data Availability Statement

The original contributions presented in this study are included in the article/Supplementary Material. Further inquiries can be directed to the corresponding author.

Acknowledgments

The authors gratefully acknowledge the support of the Brazilian agencies CNPq and CAPES.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Silva, F.B.; Vital, R.G.; Batista, P.F.; Costa, A.C.; Jakelaitis, A. Drift from herbicides application on cultivated and native plants: A review. Rev. Bras. Herbic. 2016, 15, 79–88. [Google Scholar] [CrossRef] [Scilit]
  2. Mohseni-Moghadam, M.; Wolfe, S.; Dami, I.; Doohan, D.J. Response of Wine Grape Cultivars to Simulated Drift Rates of 2,4-D, Dicamba, and Glyphosate, and 2,4-D or Dicamba Plus Glyphosate. Weed Technol. 2016, 30, 807–814. [Google Scholar] [CrossRef] [Scilit]
  3. Instituto Brasileiro de Geografia e Estatística (IBGE). Indicadores IBGE: Levantamento Sistemático da Produção Agrícola. Estatística da Produção Agrícola; IBGE: Rio de Janeiro, Brazil, 2026. Available online: https://biblioteca.ibge.gov.br/index.php/biblioteca%20catalogo?view=detalhes&id=72415 (accessed on 14 August 2026).
  4. Protas, J.F.S.; Lazzarotto, J.J.; Machado, C.A.E. Panorama da Vitivinicultura Brasileira em 2024; Embrapa Uva e Vinho: Bento Gonçalves, RS, Brazil, 2026.
  5. Rossouw, G.C.; Holzapfel, B.; Rogiers, S.; Gouot, J.; Schmidtke, L. Repercussions of four herbicides on reproductive and vegetative development in potted grapevines. Aust. J. Grape Wine Res. 2019, 25, 316–326. [Google Scholar] [CrossRef] [Scilit]
  6. McManus, S.-L.; Moloney, M.; Richards, K.G.; Coxon, C.E.; Danaher, M. Determination and Occurrence of Phenoxyacetic Acid Herbicides and Their Transformation Products in Groundwater Using Ultra High Performance Liquid Chromatography Coupled to Tandem Mass Spectrometry. Molecules 2014, 19, 20627–20649. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  7. Instituto Brasileiro do Meio Ambiente e dos Recursos Naturais Renováveis (IBAMA). Relatórios de Comercialização de Agrotóxicos; IBAMA: Brasília, Brazil, 2024. Available online: https://www.gov.br/ibama/pt-br/assuntos/quimicos-e-biologicos/agrotoxicos/relatorios-de-comercializacao-de-agrotoxicos#boletinsanuais (accessed on 22 August 2026).
  8. Dos Santos, N.C.; Da Silva, N.L.S.; Corrêia, A.F.; Mattia, V. Overview of the pesticides market and its relation with sustainable rural development in Brazil. Desenvolv. Quest. 2024, 22, e14828. [Google Scholar] [CrossRef] [Scilit]
  9. Duke, S.O. Overview of herbicide mechanisms of action. Environ. Health Perspect. 1990, 87, 263–271. [Google Scholar] [CrossRef] [PubMed]
  10. Ribeiro, D.M.; Santos, S.d.N.B.d.; dos Santos, R.F.; Silva, L.R.; Barreto, A.L.C.; Ferreira, D.C.d.S.; Pereira, K.R.d.C.L.; Neto, C.F.d.O.; de Freitas, J.M.N.; Okumura, R.S. Ação dos herbicidas no metabolismo das plantas. In Ecofisiologia de Plantas Cultivadas: Fundamentos, Estratégias Aplicadas, Adaptação e Resiliência no Ambiente Agrícola; Científica Digital: São Paulo, Brazil, 2025; pp. 8–26. [Google Scholar]
  11. Marchi, G.; Marchi, E.C.S.; Guimarães, T.G. Herbicidas: Mecanismos de Ação e Uso; Embrapa Cerrados: Planaltina, DF, Brazil, 2008.
  12. Jandova, R.; Hird, S.; Ross, E.; Van Hulle, M. Determination of Acidic Herbicides in Water Using Liquid Chromatography-Tandem Quadrupole Mass Spectrometry; Waters Corporation: Milford, MA, USA, 2018; Available online: https://www.waters.com/nextgen/us/en/library/application-notes/2018/acidic-herbicides-water-liquid-chromatography-tandem-quadrupole-mass-spectrometry.html (accessed on 6 August 2026).
  13. Butova, V.V.; Bauer, T.V.; Polyakov, V.A.; Rajput, V.D.; Minkina, T.M. Analyzing the benefits and limitations of advanced 2,4-D herbicide delivery systems. Crop Prot. 2024, 184, 106865. [Google Scholar] [CrossRef] [Scilit]
  14. Garcia, N.S.; Dayan, F.E.; Camargo, E.R.; Ceolin, B.C.; Deuner, S.; de Avila, L.A. Auxin-mimic herbicides dilemma: Their benefits and limitations. Pest Manag. Sci. 2025, 81, 4973–4992. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  15. Braz, G.B.P.; Souza, M.d.F.; Almeida, D.P.; Ferreira, C.J.B.; Cabral, R.d.S.; de Almeida, É.V.; Procópio, S.d.O. Residue of Picloram in New Agricultural Areas: Impacts, Detection, and Mitigation Measures. ACS Omega 2026, 11, 27745–27750. [Google Scholar] [CrossRef] [Scilit]
  16. European Food Safety Authority (EFSA); Álvarez, F.; Arena, M.; Auteri, D.; Leite, S.B.; Binaglia, M.; Castoldi, A.F.; Chiusolo, A.; Colagiorgi, A.; Colas, M.; et al. Peer review of the pesticide risk assessment of the active substance triclopyr (variant triclopyr-butotyl). EFSA J. 2024, 22, e8177. [Google Scholar] [CrossRef] [Scilit]
  17. Jensen, P.K.; Olesen, M.H. Spray mass balance in pesticide application: A review. Crop Prot. 2014, 61, 23–31. [Google Scholar] [CrossRef] [Scilit]
  18. Secretaria da Agricultura, Pecuária e Desenvolvimento Rural (SEAPDR). Relatório de Ocorrências de Derivas de Herbicidas Hormonais no Rio Grande do Sul: Período 2018–2022; SEAPDR: Porto Alegre, Brazil, 2022. Available online: https://www.agricultura.rs.gov.br/hormonais (accessed on 22 June 2026).
  19. Roberto, S.R.; Genta, W.; Dalazen, G.; Leles, N.R. First report of injuries associated with triclopyr herbicide drift in grapevines. Semin. Ciênc. Agrár. 2021, 42, 4163–4176. [Google Scholar] [CrossRef] [Scilit]
  20. Martins, R.X.; Carvalho, M.; Maia, M.E.; Flor, B.; Souza, T.; Rocha, T.L.; Félix, L.M.; Farias, D. 2,4-D Herbicide-Induced Hepatotoxicity: Unveiling Disrupted Liver Functions and Associated Biomarkers. Toxics 2024, 12, 35. [Google Scholar] [CrossRef] [Scilit]
  21. Bartels, M.; Brown, C.; Chung, G.; Chan, M.; Terry, C.; Gehen, S.; Corvaro, M. Review of the pharmacokinetics and metabolism of triclopyr herbicide in mammals: Impact on safety assessments. Regul. Toxicol. Pharmacol. 2020, 116, 104714. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  22. Stringhini, F.M.; Ribeiro, L.C.; Rocha, G.I.; Kuntz, J.D.d.B.; Zanella, R.; Prestes, O.D.; Adaime, M.B. Dilution of QuEChERS Extracts Without Cleanup Improves Results in the UHPLC-MS/MS Multiresidue Analysis of Pesticides in Tomato. Food Anal. Methods 2021, 14, 1511–1523. [Google Scholar] [CrossRef] [Scilit]
  23. Santana-Mayor, A.; Rodríguez-Ramos, R.; Herrera-Herrera, A.; Socas-Rodríguez, B.; Rodríguez-Delgado, M. Updated overview of QuEChERS applications in food, environmental and biological analysis (2020–2023). TrAC Trends Anal. Chem. 2023, 169, 117375. [Google Scholar] [CrossRef] [Scilit]
  24. Rejczak, T.; Tuzimski, T. Recent Trends in Sample Preparation and Liquid Chromatography/Mass Spectrometry for Pesticide Residue Analysis in Food and Related Matrixes. J. AOAC Int. 2015, 98, 1143–1162. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  25. Anastassiades, M.; Scherbaum, E.; Taşdelen, B.; Štajnbaher, D. Recent Developments in QuEChERS Methodology for Pesticide Multiresidue Analysis. In Pesticide Chemistry, 1st ed.; Wiley: Hoboken, NJ, USA, 2007; pp. 439–458. [Google Scholar] [CrossRef] [Scilit]
  26. Lehotay, S.J.; Son, K.A.; Kwon, H.; Koesukwiwat, U.; Fu, W.; Mastovska, K.; Hoh, E.; Leepipatpiboon, N. Comparison of QuEChERS sample preparation methods for the analysis of pesticide residues in fruits and vegetables. J. Chromatogr. A 2010, 1217, 2548–2560. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  27. Amaral, L.R.; Zanchin, C.F.; Floriano, L.; Ues, K.; Prestes, O.D.; Zanella, R. Multiresidue Determination of Pesticides in Potato Tuber, Peel, and Pulp by QuEChERS and UHPLC-MS/MS. Food Anal. Methods 2023, 16, 771–780. [Google Scholar] [CrossRef] [Scilit]
  28. Koesukwiwat, U.; Sanguankaew, K.; Leepipatpiboon, N. Rapid determination of phenoxy acid residues in rice by modified QuEChERS extraction and liquid chromatography–tandem mass spectrometry. Anal. Chim. Acta 2008, 626, 10–20. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  29. Sack, C.; Vonderbrink, J.; Smoker, M.; Smith, R.E. Determination of Acid Herbicides Using Modified QuEChERS with Fast Switching ESI+/ESI- LC-MS/MS. J. Agric. Food Chem. 2015, 63, 9657–9665. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  30. Ghoniem, I.R.; Attallah, E.R.; Abo-Aly, M.M. Determination of acidic herbicides in fruits and vegetables using liquid chromatography tandem mass spectrometry (LC-MS/MS). Int. J. Environ. Anal. Chem. 2017, 97, 301–312. [Google Scholar] [CrossRef] [Scilit]
  31. Hyland, K.C.; Winkler, P. Quantitation of Dicamba and Acid Herbicides in Agricultural Field Samples on SCIEX QTRAP® 6500+ System; SCIEX: Framingham, MA, USA, 2017; Available online: https://sciex.com/tech-notes/environmental-industrial/water-and-soil/quantitation-of-dicamba-and-acid-herbicides-in-agricultural-field-samples-on-sciex-qtrap-6500-system (accessed on 23 August 2026).
  32. Guo, T.; Wang, X.; Wang, H.; Hu, Y.; Zhang, S.; Zhao, R. Determination of Phenoxy Acid Herbicides in Cereals Using High-Performance Liquid Chromatography–Tandem Mass Spectrometry. J. Food Prot. 2019, 82, 1160–1165. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  33. Viera, M.S.; Rizzetti, T.M.; de Souza, M.P.; Martins, M.L.; Prestes, O.D.; Adaime, M.B.; Zanella, R. Multiresidue determination of pesticides in crop plants by the quick, easy, cheap, effective, rugged, and safe method and ultra-high-performance liquid chromatography tandem mass spectrometry using a calibration based on a single level standard addition in the sample. J. Chromatogr. A 2017, 1526, 119–127. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  34. Steinborn, A.; Alder, L.; Spitzke, M.; Dörk, D.; Anastassiades, M. Development of a QuEChERS-Based Method for the Simultaneous Determination of Acidic Pesticides, Their Esters, and Conjugates Following Alkaline Hydrolysis. J. Agric. Food Chem. 2017, 65, 1296–1305. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  35. Rezende, S.; Besil, N.; Archondo, L.; Heinzen, H.; Cesio, M.V. Multiresidue analysis of basic, neutral, and acidic pesticides in biobeds’ biomixture. MethodsX 2022, 9, 101697. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  36. Saito-Shida, S.; Nemoto, S.; Akiyama, H. Multiresidue method for determining multiclass acidic pesticides in agricultural foods by liquid chromatography-tandem mass spectrometry. Anal. Methods 2021, 13, 894–902. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  37. Islam, A.K.M.M.; Noh, H.H.; Ro, J.-H.; Kim, D.; Oh, M.-S.; Son, K.; Kwon, H. Optimization and validation of a method for the determination of acidic pesticides in cabbage and spinach by modifying QuEChERS procedure and liquid chromatography–tandem mass spectrometry. J. Chromatogr. B 2021, 1173, 122667. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  38. Li, T.; Wu, X.; Zheng, L.; Cheng, Y.; Zhao, L.; Chen, Z. Quantitative tracing of typical herbicides and their metabolites in sorghum agrosystems for fate tendency and cumulative risk. Food Chem. 2025, 464, 141638. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  39. Jin, Q.; Xu, Q.; Zhao, Z.; Si, W.; Bai, B.; Chen, L.; Zhou, C. Simultaneous Determination of Six Acidic Herbicides and Metabolites in Plant Origin Matrices by QuEChERS-UPLC-MS/MS. Molecules 2025, 30, 852. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  40. Oh, J.-K.; Kim, J.-H.; An, G.-E.-H.; Chang, H.-R. Simultaneous Determination of Six Acidic Pesticides, Including 2,4-DB and 2,4,5-T with No Established MRL in Korea Using LC-MS/MS and QuEChERS for the Safety of Imported Agricultural Products. Foods 2025, 14, 904. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  41. Gomes Ferreira, A.C.; Gonçalves, J.A.; Junior, C.E.R.; Faria, A.F. Tracing acidic herbicides and their conjugates in leaf litter via QuEChERS with alkaline hydrolysis and UHPLC–MS/MS: An auxiliary tool for chemical deforestation investigations. Talanta 2026, 301, 129281. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  42. Lehotay, S.J.; Maštovská, K.; Lightfield, A.R. Use of buffering and other means to improve results of problematic pesticides in a fast and easy method for residue analysis of fruits and vegetables. J. AOAC Int. 2005, 88, 615–629. [Google Scholar] [CrossRef] [Scilit]
  43. SANTE (European Commission). Analytical Quality Control and Method Validation Procedures for Pesticides Residues Analysis in Food and Feed. Document SANTE/11312/2021. Available online: https://food.ec.europa.eu/system/files/2023-11/pesticides_mrl_guidelines_wrkdoc_2021-11312.pdf (accessed on 29 July 2026).
  44. Vicari, M.C.; Facco, J.F.; Peixoto, S.C.; de Carvalho, G.S.; Floriano, L.; Prestes, O.D.; Adaime, M.B.; Zanella, R. Simultaneous Determination of Multiresidues of Pesticides and Veterinary Drugs in Agricultural Soil Using QuEChERS and UHPLC–MS/MS. Separations 2024, 11, 188. [Google Scholar] [CrossRef] [Scilit]
  45. Prestes, O.D.; Friggi, C.A.; Adaime, M.B.; Zanella, R. QuEChERS: Modern sample preparation method for pesticide multiresidue determination in food by chromatographic methods coupled to mass spectrometry. Quim. Nova 2009, 32, 1620–1634. [Google Scholar] [CrossRef] [Scilit]
  46. Sandín-España, P.; Mateo-Miranda, M.; López-Goti, C.; Seris-Barrallo, E.; Alonso-Prados, J.-L. Analysis of Pesticide Residues by QuEChERS Method and LC-MS/MS for a New Extrapolation of Maximum Residue Levels in Persimmon Minor Crop. Molecules 2022, 27, 1517. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  47. Rejczak, T.; Tuzimski, T. A review of recent developments and trends in the QuEChERS sample preparation approach. Open Chem. 2015, 13, 980–1010. [Google Scholar] [CrossRef] [Scilit]
  48. Tian, Y.; Liu, X.; Dong, F.; Xu, J.; Lu, C.; Kong, Z.; Wang, Y.; Zheng, Y. Simultaneous Determination of Aminopyralid, Clopyralid, and Picloram Residues in Vegetables and Fruits Using Ultra-Performance Liquid Chromatography/Tandem Mass Spectrometry. J. AOAC Int. 2012, 95, 554–559. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  49. Kittlaus, S.; Kempe, G.; Speer, K. Evaluation of matrix effects in different multipesticide residue analysis methods using liquid chromatography–tandem mass spectrometry, including an automated two-dimensional cleanup approach. J. Sep. Sci. 2013, 36, 2185–2195. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  50. Rahman, M.M.; El-Aty, A.A.; Choi, J.-H.; Kim, S.-W.; Shin, S.C.; Shim, J.-H. Consequences of the matrix effect on recovery of dinotefuran and its metabolites in green tea during tandem mass spectrometry analysis. Food Chem. 2015, 168, 445–453. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  51. de Souza, I.F.; Hoffmann, D.M.; Floriano, L.; Kemmerich, M.; Prestes, O.D.; Zanella, R. Miniaturized Straightforward Matrix Solid-Phase Dispersion for Multiresidue Determination of Pesticide Residues in Rice by UHPLC-MS/MS. Food Anal. Methods 2025, 18, 2497–2507. [Google Scholar] [CrossRef] [Scilit]
  52. Martins, G.L.; Friggi, C.A.; Prestes, O.D.; Vicari, M.C.; Friggi, D.A.; Adaime, M.B.; Zanella, R. Simultaneous LC–MS/MS Determination of Imidazolinone Herbicides Together with Other Multiclass Pesticide Residues in Soil. Clean Soil Air Water 2014, 42, 1441–1449. [Google Scholar] [CrossRef] [Scilit]
  53. Cabrera, L.D.C.; Martins, M.L.; Primel, E.G.; Prestes, O.D.; Adaime, M.B.; Zanella, R. Dispersive Solid Phase Extraction in the determination of residues and contaminants in food. Sci. Chromatogr. 2012, 4, 227–240. [Google Scholar] [CrossRef] [Scilit]
  54. Martins, M.L.; Kemmerich, M.; Prestes, O.D.; Maldaner, L.; Jardim, I.C.S.F.; Zanella, R. Evaluation of an alternative fluorinated sorbent for dispersive solid-phase extraction clean-up of the quick, easy, cheap, effective, rugged, and safe method for pesticide residues analysis. J. Chromatogr. A 2017, 1514, 36–43. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  55. Snyder, L.R.; Kirkland, J.J.; Dolan, J.W. Introduction to Modern Liquid Chromatography, 3rd ed.; John Wiley & Sons: Hoboken, NJ, USA, 2009; 960p. [Google Scholar]
  56. Hong, J.; Kawashima, A.; Okamoto, M.; Hamada, N. Evaluation of membrane filtration for cleanup in multi-residue pesticide analysis of spinach. Food Control 2017, 79, 134–142. [Google Scholar] [CrossRef] [Scilit]
  57. Kim, I.C.; Choi, J.G.; Tak, T.M. Sulfonated polyethersulfone by heterogeneous method and its membrane performances. J. Appl. Polym. Sci. 1999, 74, 2046–2055. [Google Scholar] [CrossRef]
  58. Michlig, N.; Lehotay, S.J.; Lightfield, A.R. Comparison of filter membranes in the analysis of 183 veterinary and other drugs by liquid chromatography-tandem mass spectrometry. J. Sep. Sci. 2024, 47, 2300696. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  59. Puah, P.Y.; Lee, D.J.H.; Mak, K.H.; Ang, H.J.; Chen, H.-C.; Moh, P.Y.; Fong, S.Y.; Ling, Y.S. Extractable impurities from fluoropolymer-based membrane filters—Interference in high-throughput, untargeted analysis. RSC Adv. 2019, 9, 31918–31927. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  60. Zanchin, C.F.; Floriano, L.; de Farias, B.S.; Pinto, L.A.A.; Cadaval, T.R.S.; Prestes, O.D.; Zanella, R. Carbon nanotubes stabilized in chitosan sponge (CNT-CS) as a new alternative clean-up sorbent for pesticide multiresidue determination in eggplants using QuEChERS and UHPLC-MS/MS. Anal. Bioanal. Chem. 2025, 417, 1407–1419. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  61. Ribeiro, A.L.P.; Brum, A.P.R.; Kemmerich, M.; Buzzatti, J.Z.; Rodrigues, F.T. 2,4-D in vines: A case study in the city of Jaguari-RS, Rio Grande do Sul State, Brazil. Res. Soc. Dev. 2020, 9, e2129108379. [Google Scholar] [CrossRef] [Scilit]
  62. European Union Reference Laboratories for Residues of Pesticides. Pesticides Details; EURL DataPool: Fellbach, Germany, 2026; Available online: https://spa.eurl-pesticides-datapool.eu/compounds (accessed on 8 August 2026).
  63. University of Hertfordshire. Pesticide Properties DataBase (PPDB); University of Hertfordshire: Hatfield, UK, 2026; Available online: https://sitem.herts.ac.uk/aeru/ppdb/en/ (accessed on 8 August 2026).
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.