Abstract
Heavy-crude desalter effluent carries a persistent oil dispersion that requires interfacial conditioning followed by engineered collection. We evaluated the cationic polyether demulsifier 6732B, dosed at 50 mg L−1 as-received product, in a 30-day pilot campaign combining it with fiber-ball prefiltration, coated steel-mesh coalescence and modified PVDF membrane polishing at a representative external-feed set point of 0.40 m3 h−1 (nominal skid capacity, 1 m3 h−1). With matched 38,500 mg L−1 feed, the equipment-only train left 1540 ± 73.6 mg L−1 oil, whereas the combined train reached 13.0 ± 1.12 mg L−1 (mean ± SD, n = 3), equivalent to 99.966 ± 0.003% removal (p < 0.001). Chemical-only bottle settling left 715 mg L−1 after 120 min. Three replicated stage profiles located bulk oil removal at the coalescer and a low membrane-permeate endpoint. Over 30 paired days, inlet oil of 29,000–63,000 mg L−1 was reduced to 13–38 mg L−1 (99.94–99.96%); permeate flux was 113 ± 5.8 L m−2 h−1, COD after floating-oil removal decreased by 80.0 ± 2.7% and daily rinsing restored 97.1 ± 1.3% of the clean-water permeance reference. The train is a high-load de-oiling pretreatment; the remaining 400–800 mg L−1 COD is transferred to downstream organic-pollutant treatment.