Numerical Investigation of Airflow Distribution and Zonal Ventilation Strategies in Dishwasher Systems

,
,
,
,
and
1
School of Mechanical Engineering, Tianjin University, Tianjin 300350, China
2
Kitchen & Water Heater Appliance Division, Midea Group, Foshan 528311, China
3
Laboratory of Efficient Utilization of Low and Medium Grade Energy, School of Mechanical Engineering, Tianjin University, Tianjin 300350, China
*
Author to whom correspondence should be addressed.

Abstract

This study investigates airflow distribution and zonal air-supply strategies in a dishwasher cavity using computational fluid dynamics. A cavity measuring 542 mm × 521 mm × 605 mm and containing 16 place settings is modelled. The proposed approach combines inlet–outlet configuration optimization with selective port operation to improve overall airflow distribution and direct airflow toward designated regions. Different configurations are evaluated using the coefficient of variation in velocity magnitudes at 50 sampling points. Compared with the baseline dual-inlet–dual-outlet configuration, the single-inlet–single-outlet and multi-inlet–single-main-outlet configurations reduce this coefficient from 4.03 to 2.79 and 2.25, corresponding to relative reductions of 30.77% and 44.17%, respectively. Building on the multi-inlet configuration, additional side outlets enable regional airflow redistribution through selective opening and closing of ports. Two prescribed operating scenarios are examined: Case A targets Zones 1–2, whereas Case B targets Zones 7–8. The corresponding mass flow rates in the target regions increase by 34.26% and 42.86%, respectively, relative to the reference operating conditions. These findings provide a quantitative basis for inlet–outlet arrangement and zonal air-supply design in dishwasher cavities.

1. Introduction

To address the issue of global warming, many countries worldwide have established carbon reduction targets [1,2]. Household appliances constitute a major source of energy consumption and carbon emissions [3]. In the United States, household appliance usage accounts for more than 20% of residential energy consumption and contributes to approximately 30% of residential carbon emissions [4]. Globally, household appliances consume one-quarter of building electricity, accounting for 15% of total energy consumption [5]. In response to this challenge, regions are strengthening energy efficiency standards for household appliances. The European Union has adopted Commission Regulation (EU) 2019/2022 laying down ecodesign requirements for household dishwashers under Directive 2009/125/EC, which has been applied since 1 March 2021 [6,7].
Among the many household appliances with high energy consumption, dishwashers have gained increasing popularity over the past two decades, experiencing explosive market growth. From 2015 to 2017, retail sales of dishwashers increased by 63.1%, 104.3%, and 129.2%, respectively [8]. Furthermore, studies by Porras [9] and Brunzell [10] indicate that nearly 80% of American households and over 44% of European households use dishwashers. According to Renub Research [11], the global dishwasher market is projected to reach USD 51.4 billion by 2027, with a compound annual growth rate (CAGR) of 8.2% from 2021 to 2027. Therefore, research on efficient drying technologies for dishwashers [12,13] can effectively reduce operating energy consumption, improve energy utilization efficiency, and lower carbon emissions, thereby strongly supporting carbon reduction and carbon neutrality goals.
Currently available dishwashers generally suffer from high energy consumption and long operation times [13,14]. In a survey of 6090 households across 11 European countries, mean energy consumption per cycle was 1.32 kWh for Normal programs and 0.90 kWh for Eco programs, with mean durations of 131 min and 197 min, respectively, and only 25% of users regularly selected the Eco program, largely because of its duration [14]. Consequently, full cycle times often exceed 3 h, with drying accounting for more than 30% of the total, limiting frequent short-interval use by consumers. Miao et al. [15] found that 80% to 90% of dishwasher energy consumption occurs during the heating stages of washing, rinsing, and drying. Existing dishwasher full cycle times often exceed 3 h, with drying accounting for more than 30% of the total, limiting frequent short-interval use by consumers. Applying heat pump drying technology [16,17,18] to dishwasher drying effectively addresses these issues. Research has demonstrated that heat pump dishwashers can reduce overall operational energy consumption. Wang et al. [19] compared various drying technologies, including semiconductor heating, heat pump systems, waste heat recovery, adsorption drying, and cold storage drying, based on economic and energy efficiency index (EEI) indicators. Results showed that adopting heat pump drying technology in dishwashers can achieve energy savings exceeding 20%. Furthermore, Wang et al. [20] developed a one-dimensional simulation of the entire dishwasher workflow to analyze energy consumption and distribution, proposing washing factors C1 and C2 to characterize dishwashing features from an energy perspective. Dong and Li [21] investigated a multifunctional heat-pump system for dishwashers operating in hot-water, hot-air, cooling, and high-temperature-water modes. Their thermodynamic analysis reported COP values above 3.2 under the conditions examined, illustrating the potential of heat-pump integration for dishwasher applications. Yu et al. [22], employing an unsupervised data mining framework combining data preprocessing, association rule mining, and knowledge interpretation, explored energy-saving operation strategies to reduce drying electricity consumption. Their findings indicate that excessive heat generation by the heat pump system does not effectively improve drying performance, while the air-supply method is the critical factor influencing drying efficiency.
To further enhance drying performance and shorten dish drying time in heat pump dishwashers, increasing attention has been given to fluid distribution and heat transfer characteristics within dishwasher cavities. For example, Liu et al. [23] used a Mixture two-phase model with discrete phase assumptions and transient Reynolds-averaged Navier–Stokes (RANS) simulations to analyze convective heat transfer during the dishwashing process, showing an average convective heat transfer coefficient on dish surfaces of 73 W/(m2·K) and an average heat transfer power of 718.4 W. Tan et al. [24] investigated the effect of dual-fan drying systems on airflow distribution via simulations. Results indicated that compared to single-fan systems, dual-fan configurations improve airflow velocity and humidity uniformity within the cavity, effectively reducing condensation on cavity walls and dish surfaces. Hesham et al. [25] proposed a coupled computational fluid dynamics (CFD) model to study dehumidification during drying and comprehensively evaluated desiccant materials’ moisture adsorption and heat storage performance. Li et al. [26] developed a novel bidirectional ventilation control strategy combining switchable air ducts and dual fans to integrate intake and exhaust modes, improving airflow uniformity and raising the drying performance index from 0.90 to 1.18, an increase of 31.11%. Chen et al. [27] analyzed flow fields of dishwasher drying models with a single inlet and single outlet at different positions, demonstrating that larger and longer airflow coverage improves drying effectiveness. These prior configurations differ in their design focus and are not mutually exclusive. The dual-fan configuration is defined by the number and placement of the driving fans; it redistributes the supplied air through an additional fan, without changing the overall flow direction. The bidirectional ventilation scheme switches the intake and exhaust roles of the ducts, thereby reversing the overall flow path between intake and exhaust modes. In contrast, the zonal scheme examined in this study keeps the fan number and overall flow direction unchanged; on a fixed multi-inlet–multi-outlet structure, it selectively opens the inlets and outlets of a specified region to route air toward that region. Recent studies have quantitatively demonstrated the importance of airflow in appliance drying. Yang et al. [28] reported that increasing the airflow rate from 30 to 45 m3/h increased the average drying score of a heat-pump dishwasher from 0.64 to 0.92, while the increase from 40 to 45 m3/h was accompanied by a marked rise in energy consumption. Xie et al. [29] reported increases of 13.1% in COP and 69.8% in dehumidification capacity with increasing moist-air flow rate over the investigated range. Related evidence from clothes drying also highlights the interaction between airflow, drying time, and energy efficiency. Accordingly, the present study compares inlet–outlet configurations and zonal ventilation strategies at a prescribed total airflow rate.
This study combines inlet–outlet configuration comparison with coordinated regional port selection in a dishware-filled dishwasher cavity. Unlike the dual-fan and flow-reversal approaches discussed above, the proposed scheme redistributes a fixed total air supply by selectively activating inlet groups and regional outlets without changing the overall flow direction. Its contribution is the quantitative assessment of sampled velocity dispersion and target-region airflow allocation under prescribed moisture scenarios.

2. Model and Methods

2.1. Physical Model

This study investigates inlet–outlet configurations and zonal air-supply strategies to improve airflow distribution within a dishwasher cavity. The investigation procedure is illustrated in Figure 1. First, the dishwasher geometry was simplified while retaining the dishware arrangement to represent its obstruction and redirection of airflow. Five outlet layouts were compared at a fixed inlet position, both with and without dishware, to examine how outlet placement affects cavity airflow. The baseline dual-inlet–dual-outlet configuration was then compared with single-inlet–single-outlet and multi-inlet–single-outlet configurations. Sampled velocity statistics and streamline distributions were used to evaluate spatial velocity dispersion and airflow pathways around the dishware. Building on these comparisons, selective operation of the upper and lower inlet groups was introduced to adjust regional air supply according to residual-moisture conditions. Additional regional outlets were subsequently incorporated to provide more flexible inlet–outlet combinations. Two prescribed residual-moisture scenarios were examined to assess how coordinated port selection redistributes the supplied airflow towards selected regions at a constant total inlet flow rate.
Figure 1. Technical route of dishwasher cavity structural optimization and control strategies.
Figure 2a shows the actual physical model of the dishwasher cavity, which includes dishware and other auxiliary components such as washing devices, control units, and dishwasher racks. To simplify the computation, the actual dishwasher cavity model was simplified, resulting in an inner cavity size of 542 mm × 521 mm × 605 mm. Small surfaces on the dishware were merged, and rounded edges on dishes were neglected. Auxiliary structures, including dish racks and rotating spray arms, were omitted to reduce geometric and meshing complexity, while the dishware arrangement was retained to represent the principal load geometry. The simplified dishwasher cavity model is shown in Figure 2b, where the blue-marked parts represent the model inlets and the red-marked parts represent the outlets. The diameters of the inlet and outlet are both 58 mm. The model contains 16 place settings, corresponding to the rated capacity of the dishwasher investigated. This full-load arrangement was selected to represent the airflow obstruction and spatial distribution of dishware under the appliance’s nominal loading condition.
Figure 2. Dishwasher cavity physical model: (a) actual model; (b) simplified model.
Airflow velocity near dishware surfaces governs local boundary-layer development and contributes to convective heat and mass transfer [30]. Its spatial distribution determines how effectively the air supply reaches different parts of the cavity, making velocity-field analysis an important basis for dishwasher airflow design. Comparing inlet–outlet configurations can reveal how airflow pathways interact with dishware placement and identify regions that receive insufficient ventilation.
This study uses the coefficient of variation in sampled velocity magnitudes to quantify airflow uniformity across the cavity. A lower coefficient indicates a more even velocity distribution among the sampling points. Combined with regional airflow quantities, this metric enables quantitative comparison of inlet–outlet configurations and guides selective air supply toward less-ventilated regions. The analysis links cavity-scale airflow distribution with zonal air-supply design. Figure 3 shows five different inlet and outlet layout schemes. The inlet position is fixed at the lower right corner of the right sidewall, while outlet positions are distributed on different sidewalls: the front, right, top, left, and rear walls of the cavity. To simplify the model and facilitate analysis, the dishware model within the dishwasher cavity was ignored in this part, as shown in Figure 4. The difference between Figure 3 and Figure 4 lies in whether the influence of dishware is considered, focusing on how dishware placement affects the choice of inlet and outlet layout schemes.
Figure 3. Dishwasher cavity inlet structure optimization considering dishware: (a) front outlet; (b) right outlet; (c) top outlet; (d) left outlet; (e) rear outlet.
Figure 4. Dishwasher cavity inlet structure optimization ignoring dishware: (a) front outlet; (b) right outlet; (c) top outlet; (d) left outlet; (e) rear outlet.
To compare the spatial distribution of airflow among the inlet–outlet configurations, 50 velocity sampling points were arranged in two horizontal planes within the cavity, as shown in Figure 5. The upper and lower planes are located 150 mm below the top wall and 150 mm above the bottom wall, respectively. The point spacing is 90 mm in the lateral direction and 87 mm in the front-to-back direction. The velocity coefficient of variation, S [31], is calculated from the sampled velocity magnitudes using Equation (1).
S = 1 n ∑ v i − v ¯ 2 v ¯
Figure 5. Velocity measurement point arrangement in dishwasher cavity: (a) front view; (b) top view.
Here, n is the number of velocity measurement points, vi is the velocity at each point (m/s), and v ¯ is the average velocity over all measurement points (m/s). The dimensionless coefficient S is the standard deviation of these magnitudes divided by their mean. Values greater than unity indicate that the standard deviation exceeds the mean, reflecting pronounced spatial variation within the sampled velocity field. A lower S indicates reduced relative velocity dispersion and provides a quantitative basis for comparing airflow distributions among the investigated configurations.

2.2. Mathematical Model

The drying progression in dishwashers is generally expressed through recursive equations involving continuous moisture evaporation on dish surfaces and heat and mass transfer between moist air and the load. These equations include time-dependent convective heat transfer and mass transfer coefficients, making them complex nonlinear equations that are difficult to solve directly in a continuous manner.
To simplify the model solution and mesh generation, the following assumptions are made in this study:
The influence of air ducts is neglected; the inlet airflow direction is always perpendicular to the cavity wall. The integration of the dishwasher cavity and air duct will be considered in future structural optimizations.
There is no moisture migration inside the dishes; moisture is assumed to adhere only to dish surfaces. The main materials of the dishes are ceramic, with some made of glass, melamine, or steel. Physical properties of dish materials are listed in Table 1.
Table 1. Physical properties of dishware materials [20].
The cavity walls are adiabatic, ignoring heat exchange with the external environment.
The air state at the evaporator inlet is the same as at the dishwasher outlet, and the air state at the condenser outlet equals that at the dishwasher inlet.
Water droplets are initially distributed uniformly over the dishware surfaces, and moisture removal occurs through evaporation. Droplet sliding and airflow-induced removal are neglected. For each dishware item, a uniform surface evaporation flux is prescribed using the surrounding air conditions and the dishware temperature.
The present model is intended to compare cavity airflow distributions among inlet–outlet layouts and zonal ventilation configurations under prescribed airflow conditions. External ducts and the fan performance curve are excluded, and the inlet flow is specified normal to the inlet boundary. These conditions provide a consistent basis for comparing internal airflow redistribution; appliance-level operating flow rates will also depend on duct resistance, fan characteristics, and valve settings. The omission of racks and spray arms simplifies internal obstructions, so the results primarily describe airflow patterns associated with the modeled cavity and dish arrangement. Adiabatic walls and the uniform evaporation assumption provide idealized thermal and moisture boundary conditions, while practical drying involves wall heat exchange and spatially varying surface moisture. For valve-switched multi-port operation, each configuration represents an idealized operating state with its prescribed flow allocation. The comparison therefore focuses on airflow distribution within these states. Switching transients, valve leakage, and the coupled fan–duct response are relevant considerations for subsequent system-level development.
The overall computational model primarily consists of two regions: the air region and the dishware region. The air region involves solving the continuity, momentum, and energy equations, while the dishware region involves only the energy equation.
(1)
Continuity Equation
∂ ρ ∂ t + ∇ ⋅ ρ U → = S m
Here, ρ is the air density (kg/m3), t is time (s), U → is the velocity vector (m/s), and Sm is the mass source due to droplet evaporation (kg/(m3·s)).
(2)
Momentum Equation
∂ ∂ t ρ U → + ∇ ⋅ ρ U → U → = − ∇ p + ∇ ⋅ μ ∇ U → + ρ g →
Here, p is the static pressure of air (Pa), μ is the dynamic viscosity (Pa·s), and g is gravitational acceleration (m/s2).
The standard k–ε turbulence model is employed in this study. The transport equations for turbulent kinetic energy k and its dissipation rate are given as
∂ ∂ t ρ k +   ∂ ∂ x i ρ k u i = ∂ ∂ x j μ + μ t σ k ∂ k ∂ x j + G k + G b − ρ ε − Y M
∂ ∂ t ρ ε + ∂ ∂ x i ρ ε u i = ∂ ∂ x j μ + μ t σ ε ∂ ε ∂ x j + C 1 ε ε k G k + C 3 ε G b − C 2 ε ρ ε 2 k
μ t = ρ C μ k 2 ε
where k is the turbulent kinetic energy (m2/s2); ɛ is the turbulence dissipation rate (m2/s3); and σk and σɛ are the turbulent Prandtl numbers for k and ɛ, with default values of 1.0 and 1.3, respectively. Gk and Gb represent the production of turbulence due to mean velocity gradients and buoyancy, respectively. YM accounts for the contribution of compressibility-induced fluctuating dilation to the overall dissipation rate. C1ε, C2ε, and Cμ are model constants with default values of 1.44, 1.92, and 0.09, respectively. μt is the turbulent viscosity (N·s/m2), as calculated in Equation (6).
(3)
Energy Equations
For the air region:
ρ c p ∂ T ∂ t + U → ⋅ ∇ T = ∇ ⋅ λ ∇ T + S T
For the dishware region:
ρ c p ∂ T ∂ t = ∇ ⋅ λ ∇ T − S T
S T = m ˙ ⋅ L h V
Here, cp is the specific heat capacity (J/(kg·K)), T is the temperature (K), λ is the thermal conductivity (W/(m·K)), and ST is the heat sink due to evaporative cooling (W/m3). m ˙ is the droplet evaporation rate on dish surfaces (kg/s), and Lh is the latent heat of vaporization (J/kg), as shown in Equation (9). The water-vapor mass fraction is obtained from the species transport equation. Air temperature, velocity magnitude, and relative humidity are sampled around each dishware item and averaged to represent its surrounding air conditions. These quantities, together with the dishware temperature, determine the evaporation rate.

2.3. Numerical Method and Boundary Conditions

In this study, CFD was employed to optimize the layout of inlet and outlet positions in the dishwasher cavity. First, the three-dimensional geometry of the dishwasher cavity was constructed and simplified using SpaceClaim. An unstructured mesh with five near-wall layers was generated using Fluent Meshing. Model setup, boundary condition definition, and solver configuration were performed in Fluent. Finally, post-processing of simulation results was conducted using CFD-Post.
Transient simulations were performed using the standard k–ε turbulence model with standard wall functions for near-wall treatment. The simulations were performed using a transient URANS formulation with a time step of 0.1 s. Each simulation comprised 21,000 time steps, corresponding to a total physical duration of 2100 s. The energy and water-vapor species transport equations were also enabled. Dishware-surface evaporation was implemented using boundary terms defined through user-defined functions (UDFs). The governing equations were discretized using the finite volume method (FVM). Second-order upwind discretization was applied to the convective terms of the momentum, turbulence, and energy equations. The pressure staggering option (PRESTO!) scheme was used for pressure discretization. The semi-implicit method for pressure-linked equations (SIMPLE) algorithm was adopted for pressure–velocity coupling.
The relaxation factors were set as follows: pressure—0.3; density—1.0; body force—1.0; momentum—0.7; turbulent kinetic energy—0.8; turbulent viscosity—0.8; and energy—1.0. To ensure computational accuracy, the convergence criteria for the continuity and momentum equations were set to 10−4, and for the energy equation to 10−6.
The total volumetric flow rate supplied through the active inlets was prescribed as 3.17 × 10−3 m3/s. This value represents the combined flow through all active inlets rather than the flow rate at each individual inlet. For a single circular inlet with a diameter of 58 mm, the prescribed flow rate corresponds to an inlet velocity of approximately 1.2 m/s. The inlet air temperature was set to 50 °C. The active outlets were specified as pressure outlets with a gauge pressure of 0 Pa. No-slip boundary conditions were imposed on the cavity walls and dishware surfaces. Air-density variations associated with buoyancy were represented using the Boussinesq approximation. All solid–fluid and solid–solid interfaces were defined as thermally coupled boundaries, ensuring continuity of heat flux and temperature across interfaces. The initial temperature of both the dishware and the cavity air was set to 70 °C. The cavity walls were assumed to be adiabatic, and heat loss to the external environment was neglected.

2.4. Model Validation

2.4.1. Mesh Sensitivity Analysis

The mesh-sensitivity study was performed on the full dishware-containing cavity model. An unstructured mesh was generated to accommodate the complex dishware geometry, as shown in Figure 6a. Mesh sensitivity was examined using meshes containing approximately 2–10 million cells. Figure 6b compares the mean velocity magnitude and the coefficient of variation calculated at the sampling points.
Figure 6. Mesh sensitivity analysis: (a) computational mesh; (b) mean sampled velocity magnitude and velocity coefficient of variation for different mesh sizes.
Relative to the 10-million-cell mesh, the 6-million-cell mesh gives differences below 0.74% in the velocity coefficient of variation and 0.50% in the mean sampled velocity magnitude. Considering the small changes in both quantities with further mesh refinement, the 6-million-cell mesh was selected to balance computational accuracy and computational cost in the subsequent configuration comparisons.

2.4.2. Velocity Field Validation

In this study, the standard k–ε model was adopted as an engineering closure for comparing the mean airflow distributions produced by different inlet–outlet configurations. The comparison focuses on airflow pathways, sampled velocity statistics, and regional flow allocation. The numerical approach was assessed against the duct–flow measurements reported by Zhang et al. [30].
As shown in Figure 7a, the experimental setup reported by Zhang et al. [30] consists of a centrifugal fan, a plenum chamber, and rectangular upstream and downstream ducts. The duct cross–section is 320 mm × 250 mm, while the pressure chamber measures 600 mm × 650 mm. The centrifugal fan delivers an inlet velocity of 8.686 m/s. The lengths of the upstream and downstream ducts are 6 m and 18 m, respectively.
Figure 7. Comparison with the reference duct-flow measurements reported by Zhang et al. [32]: (a) experimental configuration; (b) measurement locations; (c) simulated and measured velocities.
During the experiment, velocity measurements were taken at five locations: 1.0 m and 2.5 m upstream, and 1.0 m, 9.0 m, and 15.5 m downstream of the plenum chamber. Measurements were made using a TSI 8386A hot-wire anemometer. At each cross–section, five velocity probes were arranged along the centerline, as illustrated in Figure 7b. Measurements were obtained at five cross–sections, with five sampling locations per cross-section, giving 25 spatial measurement locations. Each location was measured five times, and the averaged velocity was used for comparison.
Figure 7c compares the simulated velocities with the experimental measurements. The maximum absolute deviation is less than 0.3 m/s, and the relative errors are within 5%, indicating agreement between the calculated and measured velocities at the sampled locations in the reference duct configuration. This comparison assesses velocity predictions in the reference duct configuration. Direct experimental validation of airflow and drying behavior in the dishware-filled dishwasher cavity was not performed.

3. Results and Discussion

3.1. Optimization of Inlet and Outlet Positions in the Dishwasher Cavity

3.1.1. Optimization Considering the Presence of Dishware

Figure 8 shows the velocity streamlines for different inlet and outlet layouts in the dishwasher cavity with dishware considered. It can be observed that when the outlet is located at different positions, the resulting airflow distribution, direction, and velocity within the cavity vary accordingly. Across the five configurations, the streamlines show stronger airflow in the central region and weaker circulation in several corner regions. These spatial differences highlight the influence of outlet position on airflow distribution around the dishware.
Figure 8. Streamline diagrams of inlet–outlet layout optimization with dishware considered: (a) Layout 1; (b) Layout 2; (c) Layout 3; (d) Layout 4; (e) Layout 5; (f) velocity coefficients of variation for the five layouts with dishware.
The velocity coefficients of variation for Layouts 1–5 are 2.83, 2.79, 3.00, 2.83, and 2.85, respectively. Layout 2 exhibits the lowest calculated value, 0.04 below those of Layouts 1 and 4, and was selected for the subsequent inlet-number investigation.

3.1.2. Optimization Without Dishware Consideration

Figure 9 presents the velocity streamlines for the five layouts without dishware. Removing the dishware changes the airflow pathways and recirculation patterns within the cavity. The velocity coefficients of variation for Layouts 1–5 are 1.68, 1.62, 1.69, 1.71, and 1.72, respectively. Layout 2 gives the lowest calculated value in this comparison.
Figure 9. Velocity streamlines of inlet/outlet structure optimization without considering utensils: (a) Layout 1; (b) Layout 2; (c) Layout 3; (d) Layout 4; (e) Layout 5; (f) velocity coefficients of variation for the five layouts without dishware.
Layout 2 gives the lowest calculated coefficient in both loading conditions and was adopted for the subsequent configuration study. Dishware was retained in the remaining simulations to represent its obstruction and redirection of cavity airflow.

3.2. Optimization of Inlet Numbers

Three inlet–outlet configurations are compared: the baseline dual–inlet–dual–outlet configuration, the single-inlet–single-outlet configuration using Layout 2, and the multi-inlet–single-outlet configuration. Table 2 summarizes their port arrangements and calculated velocity coefficients of variation.
Table 2. Comparison of principal inlet–outlet configurations and velocity coefficients of variation.

3.2.1. Flow Field Analysis of the Dual-Inlet–Dual-Outlet Model

Figure 10 compares the baseline dual-inlet–dual-outlet configuration with the single-inlet–single-outlet configuration. In the baseline configuration, the streamlines show direct connections between the inlets and outlets, while circulation near several dishware regions is weaker. Such preferential discharge paths allow part of the supplied air to leave the cavity with limited interaction with the surrounding dishware. Changing the inlet–outlet arrangement redistributes the flow pathways through the dishware-filled cavity, as shown in Figure 10c,d. The velocity coefficient of variation decreases from 4.03 to 2.79, corresponding to a relative reduction of 30.77%. This quantitative change accompanies the redistribution observed in the streamline plots and indicates lower relative dispersion of the sampled velocity magnitudes.
Figure 10. Comparison of velocity streamline distributions in the dishwasher cavity before and after optimization: (a) front view of initial model; (b) top view of initial model; (c) front view of optimized model; (d) top view of optimized model.

3.2.2. Flow Field Analysis of the Multi-Inlet–Single-Outlet Model

The multi-inlet–single-outlet configuration distributes the prescribed total air supply among multiple inlet locations. As shown in Figure 11a, the distributed inlets introduce air into different parts of the dishware load, providing supply paths to regions separated by plates, bowls, and other dishware. These obstructions divide and redirect the incoming jets, making the spatial placement of the inlets important for airflow distribution within the cavity. Supplying air at multiple locations reduces the dependence of regional ventilation on penetration from a single inlet. Meanwhile, the single outlet establishes a common discharge route, and its position relative to the distributed inlets shapes the flow pathways through the dishware-filled cavity, as illustrated in Figure 11b. The velocity coefficient of variation decreases to 2.25, corresponding to a relative reduction of 44.17% from the baseline value of 4.03 and 19.35% from the single-inlet–single-outlet value of 2.79. The lower coefficient indicates reduced relative dispersion of the sampled velocity magnitudes, supporting the comparison of airflow distributions shown in the streamline plots. Beyond whole-cavity airflow distribution, the multi-inlet arrangement provides selectable supply locations for regional operation. By opening or closing the corresponding inlet groups while maintaining the total supply flow rate, a greater share of the airflow can be allocated to selected dishware regions. This flexibility forms the structural basis for the moisture-based regional air-supply strategies examined in the following sections.
Figure 11. Velocity streamline distribution in the dishwasher cavity: (a) front view of multi-inlet-single-outlet model; (b) top view of multi–inlet–single–outlet model.
The relevance of these airflow changes to moisture removal arises from air renewal near wet dishware surfaces. In the evaporation model, the local airflow affects the convective mass-transfer coefficient, while evaporation also depends on the water-vapor density difference between the wet surface and the surrounding air. Flow pathways that bring supplied air into contact with wet dishware can support vapor removal. Recirculation can promote mixing, but weakly exchanged recirculation regions may retain humid air and reduce the evaporation driving force. Airflow path length therefore needs to be considered together with local velocity and exchange with the main flow: a longer pathway is useful when it improves contact and air renewal around wet surfaces.

3.3. Air-Supply Control Strategy for Inlet Configuration

Figure 12 illustrates the proposed moisture-based inlet-selection logic. Whole-cavity supply is maintained while both the upper and lower regions require drying. Once one region reaches the drying criterion, its inlet group is closed, and the air supply is redirected toward the remaining wet region. The evaporation UDF tracks residual water mass as a numerical indicator of wetness. Physical wetness sensing and sensor-based feedback are outside the present model. The airflow comparisons evaluate selected port configurations representing this control logic, while switching times and actuator response are reserved for subsequent implementation studies.
Figure 12. Inlet air-supply control strategy.
Figure 13 compares the airflow distributions produced by upper- and lower-region supply. Selective inlet operation changes the allocation of the supplied air between the two regions, providing a means of matching regional air supply to the distribution of residual water.
Figure 13. Velocity streamlines under upper- and lower-region air-supply configurations: (a) front view–upper utensils partially dry; (b) top view–upper utensils partially dry; (c) front view–lower utensils partially dry; (d) top view–lower utensils partially dry.
As shown in Figure 13, closing the lower inlet group increases the share of supplied airflow delivered to the upper region, whereas closing the upper inlet group increases the share delivered to the lower region.

3.4. Optimization of Outlet Positions and Quantities

Figure 14 illustrates a regional outlet-selection concept used in battery thermal management, in which selectable discharge paths adjust airflow through different regions. This principle is applied here to the dishwasher cavity: coordinating regional outlets with the active inlet groups provides airflow paths through dishware regions containing residual water, supporting local air renewal and water-vapor removal. Eight regional outlets were added to the front and rear sidewalls to form a multi-inlet–multi-outlet (MIMO) configuration, as shown in Figure 15.
Figure 14. Schematic diagram of the battery pack thermal management structure [31].
Figure 15. MIMO configuration of the dishwasher cavity.
This multi-outlet configuration allows more flexible control strategies by selectively opening or closing side outlets based on drying requirements. As shown in Figure 16a, the cavity is divided into eight zones. Figure 16b illustrates a simplified single-inlet–single-outlet (SISO) arrangement for each zone. The corresponding port-selection logic and representative operating scenarios are described in Section 3.5.
Figure 16. Zonal partitioning and schematic inlet–outlet arrangements: (a) MIMO configuration per zone; (b) SISO configuration per zone.

3.5. Outlet Air-Supply Control Strategy

3.5.1. Control Strategy Design

Figure 17 presents the moisture-based air-supply strategy for the multi-inlet–multi-outlet configuration. During whole-cavity operation, all inlet groups and the main outlet are active. The transition to regional supply occurs when some regions satisfy the drying criterion while residual water remains in others. A region is considered dry when no residual water remains on its dishware. The inlet groups and regional outlets serving the regions that still require drying are then selected, increasing their share of the fixed total supply flow. For example, when residual water remains only in Zone 1, the inlet group serving Zone 1 and its associated outlet are activated to concentrate the air supply in that region.
Figure 17. Airflow control strategy for the multi-inlet–multi-outlet (MIMO) dishwasher model.

3.5.2. Airflow Redistribution Under Prescribed Moisture Scenarios

Two prescribed residual-moisture scenarios are examined to illustrate the regional port-selection strategy. Case A targets Zones 1 and 2, whereas Case B targets Zones 7 and 8. For each scenario, the corresponding inlet groups and regional outlets are selected while the total inlet flow rate remains fixed at 3.17 × 10−3 m3/s. Figure 18 compares the resulting airflow pathways through the target regions. Cases A and B are prescribed scenarios representing residual water in Zones 1–2 and Zones 7–8, respectively. These scenarios are used to compare the airflow response to regional port selection rather than being identified from an automatically simulated switching sequence. No specific switching time is assigned to either case.
Figure 18. Airflow redistribution under prescribed residual-moisture scenarios: (a) undried zones 1–2; (b) front view with outlets 1–2 activated; (c) top view with outlets 1–2 activated; (d) undried zones 7–8; (e) front view with outlets 7–8 activated; (f) top view with outlets 7–8 activated.
Figure 19 quantifies airflow redistribution toward the selected regions. The target-region mass flow rates increase by 34.26% and 42.86% in Cases A and B, respectively, relative to the corresponding reference configurations. An increased share of airflow in the selected regions is consistent with the intended port-selection mechanism. The reported values quantify the redistribution achieved by the investigated geometry at a fixed total supply flow rate. These percentages describe regional airflow changes; drying-time and energy benefits require evaluation using a common drying endpoint and the complete air-supply system.
Figure 19. Comparison of target-region mass flow rates between reference and regional-supply configurations.

3.6. Engineering Implementation and Further Evaluation

The regional air-supply scheme provides flexibility to match airflow allocation to the spatial distribution of residual water. Its practical implementation requires controllable port groups, connecting ducts, seals, and actuators. These components add manufacturing, assembly, and maintenance costs. Grouped port actuation is a potential means of reducing actuator count, although larger groups provide coarser spatial control. An economic assessment should therefore compare component and maintenance costs with measured changes in drying duration and total electrical consumption over the appliance lifetime.
Port selection also changes system resistance and the fan operating point. Maintaining the prescribed supply flow requires coordination between valve operation and fan control, while sealing is needed to limit leakage through inactive branches. A fixed total airflow rate does not imply constant fan power, because port selection changes the required pressure rise and potentially the fan efficiency. Subsequent system-level evaluation should therefore compare drying time, fan electrical power, and total cycle energy at the same final residual-moisture criterion. Valve restrictions and increased local velocities may alter aerodynamic noise. Inactive outlet branches may retain humid air and develop condensation when their surfaces fall below the local dew-point temperature; branch geometry, drainage, and moisture retention therefore require consideration. In a heat-pump dishwasher, changes in return-air temperature, humidity, and flow distribution can affect heat-exchanger operation, so the regional supply scheme should be evaluated together with the fan and heat-pump circuit.
The present configuration comparisons use one full-load dishware arrangement, a prescribed inlet flow rate of 3.17 × 10−3 m3/s, and an inlet temperature of 50 °C. The simplified geometry omits racks, spray arms, and external ducts, and the cavity walls are treated as adiabatic. Further evaluation should assess the sensitivity of regional airflow redistribution to dishware loading, port resistance, valve leakage, supply flow rate, temperature, and initial moisture distribution, together with numerical uncertainty in the principal comparison metrics. Prototype testing should combine residual-water measurements with electrical power, pressure, noise, and condensation measurements to establish the operating and economic performance of the complete system.

4. Conclusions

In this study, the positions and quantities of inlets and outlets in a dishwasher cavity were systematically optimized through simulation. Based on the improved multi-inlet–multi-outlet cavity model, a regional air-supply strategy was proposed to adjust airflow allocation among dishware regions. The main conclusions are as follows:
  • Among the five inlet–outlet layouts examined, Layout 2, with the inlet and outlet on the same cavity wall, gives the lowest calculated velocity coefficients of variation: 2.79 with dishware and 1.62 without dishware. This layout was adopted for the subsequent inlet-number investigation.
  • The velocity coefficient of variation decreases from 4.03 in the baseline dual-inlet–dual-outlet configuration to 2.79 in the single-inlet–single-outlet configuration and 2.25 in the multi-inlet–single-outlet configuration, corresponding to relative reductions of 30.77% and 44.17%, respectively.
  • Air-supply control strategy for outlets: The multi-outlet configuration allowed finer regional control of the airflow. By closing inlets and outlets in already dried zones, airflow could be concentrated in zones with residual moisture. In Case A (Zones 1 and 2 not fully dried) and Case B (Zones 7 and 8 not fully dried), airflow to the target zones increased by 34.26% and 42.86%, respectively, under the proposed control strategy.
The results provide a quantitative basis for inlet–outlet configuration and regional air-supply design in dishwasher cavities. The findings provide theoretical support and practical guidance for future dishwasher design and offer valuable insights for advancing drying technology in household appliances.

Author Contributions

Conceptualization, Y.W. and G.W.; methodology, J.W.; software, Z.W. and Y.L.; validation, Y.W. and J.W.; formal analysis, J.Z.; investigation, Y.L.; resources, J.W.; data curation, J.W.; writing—original draft preparation, Y.W.; writing—review and editing, J.W.; visualization, J.W.; supervision, Y.W.; project administration, Y.L.; funding acquisition. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Data Availability Statement

The original contributions presented in this study are included in the article. Further inquiries can be directed to the corresponding author.

Conflicts of Interest

Author Yaodong Wang was employed by the company Midea Group. The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest. The authors declare that the company had the following involvement with the study: proposed the conceptual design and conducted part of the CFD simulation work (study design, analysis).

Nomenclature

Symbols
cpSpecific heat capacity (J·kg−1·K−1)
C1εModel constant in the ε equation (-)
C2εModel constant in the ε equation (-)
C3εModel constant in the ε equation (-)
CμTurbulent viscosity model constant (-)
gGravitational acceleration vector (m·s−2)
GbProduction of turbulent kinetic energy due to buoyancy (W·m−3)
GkProduction of turbulent kinetic energy due to mean velocity gradients (W·m−3)
kTurbulent kinetic energy per unit mass (m2·s−2)
LhLatent heat of vaporization (J·kg−1)
m ˙ Water evaporation mass flow rate from dishware surfaces (kg·s−1)
nNumber of velocity sampling points (-)
pStatic pressure (pa)
SCoefficient of variation in sampled velocity magnitudes (-)
SmVolumetric mass source due to water evaporation (kg· m−3·s−1)
STVolumetric energy source or sink associated with evaporation (W· m−3)
ttime (s)
TTemperature (K)
uiVelocity component in the i-th coordinate direction (m·s−1)
UAir velocity vector (m·s−1)
viVelocity magnitude at the i-th sampling point (m·s−1)
v ¯ Mean velocity magnitude over all sampling points (m·s−1)
VVolume (m3)
xCartesian spatial coordinates (m)
YMContribution of fluctuating dilatation to turbulent kinetic energy dissipation (W· m−3)
ΔPf,FFriction pressure change term (Pa)
εTurbulent kinetic energy dissipation rate per unit mass (m2·s−3)
λThermal conductivity (W· m−1· K−1)
μDynamic viscosity (Pa·s)
μtTurbulent dynamic viscosity (Pa·s)
ρDensity (kg· m−3)
σkTurbulent Prandtl number for k
σεTurbulent Prandtl number for ε
Subscripts
bBuoyancy
i,jSampling-point index or Cartesian coordinate index, depending on context
kTurbulent kinetic energy
tTurbulent
εTurbulent dissipation rate

References

  1. Al-Rbaihat, R.; Alahmer, H.; Al-Manea, A.; Altork, Y.; Alrbai, M.; Alahmer, A. Maximizing efficiency in solar ammonia–water absorption refrigeration cycles: Exergy analysis, concentration impact, and advanced optimization with GBRT machine learning and FHO optimizer. Int. J. Refrig. 2024, 161, 31–50. [Google Scholar] [CrossRef] [Scilit]
  2. Wang, C.; Song, J.; Zheng, W.; Liu, Z.; Lin, C. Analysis of economy, energy efficiency, environment: A case study of the CHP system with both civil and industrial heat users. Case Stud. Therm. Eng. 2022, 30, 101768. [Google Scholar] [CrossRef] [Scilit]
  3. Yang, S.; Yun, B.Y.; Kim, Y.U.; Hong, T.; Kim, S. Experimental-based energy performance evaluation of low-cost retrofit strategy for aging low-rise residential building for carbon neutrality. Case Stud. Therm. Eng. 2022, 40, 102535. [Google Scholar] [CrossRef] [Scilit]
  4. Wang, W.; Liu, X.; Shi, Z.; Liu, H. Investigation of heat transfer and energy distribution inside dishwasher based on a coupled 3D-1D simulation method. Case Stud. Therm. Eng. 2023, 49, 103355. [Google Scholar] [CrossRef] [Scilit]
  5. Radpour, S.; Mondal, M.A.H.; Kumar, A. Market penetration modeling of high energy efficiency appliances in the residential sector. Energy 2017, 134, 951–961. [Google Scholar] [CrossRef] [Scilit]
  6. European Commission. Commission Regulation (EU) 2019/2022 of 1 October 2019 laying down ecodesign requirements for household dishwashers pursuant to Directive 2009/125/EC of the European Parliament and of the Council, amending Commission Regulation (EC) No 1275/2008 and repealing Commission Regulation (EU) No 1016/2010. Off. J. Eur. Union 2019, L 315, 267–284. Available online: https://eur-lex.europa.eu/eli/reg/2019/2022/oj/eng (accessed on 12 November 2026).
  7. European Parliament and Council of the European Union. Directive 2009/125/EC of the European Parliament and of the Council of 21 October 2009 establishing a framework for the setting of ecodesign requirements for energy-related products (recast). Off. J. Eur. Union 2009, L 285, 10–35. Available online: https://eur-lex.europa.eu/eli/dir/2009/125/oj/eng (accessed on 12 November 2026).
  8. Su, L. Riding the market boom: Rapid adoption of dishwashers. Househ. Appl. 2018, 78–79. Available online: https://kns.cnki.net/kcms2/article/abstract?v=YsZ6lxCJneQKPMCtjAcmGsZ5b03cZKIHQSwYVghnj2f1eWK78EqTjLKS-mS30plNvZjBKdDsX8nkuJnr2lLJAqqRyL7oGQly1lXJPf_jJ6fJbfh_AqsVddTmClGpi4wSrtr590O3XO4OIn1pbyRXVODEhz0cX7wJ6CirYvz-Zbc=&uniplatform=NZKPT (accessed on 12 November 2026).
  9. Porras, G.; Keoleian, G.; Lewis, G.; Seeba, N. A guide to household manual and machine dishwashing through a life cycle perspective. Environ. Res. Commun. 2020, 2, 021004. [Google Scholar] [CrossRef] [Scilit]
  10. Brunzell, L.; Renström, R. Recommendations for revising the energy label system for dishwashers: Supporting sustainable development and usage through the interaction of energy labels, technical improvements and consumer behaviour. Energy Effic. 2020, 13, 145–155. [Google Scholar] [CrossRef] [Scilit]
  11. Renub Research. Dishwasher Market, Size, Share, Global Forecast 2022–2027, Industry Trends, Growth, Insight, Impact of COVID-19, Company Analysis. 2022. Available online: https://www.renub.com/global-dishwasher-market-p.php (accessed on 12 November 2026).
  12. Bengtsson, P.; Berghel, J.; Renström, R. A household dishwasher heated by a heat pump system using an energy storage unit with water as the heat source. Int. J. Refrig. 2015, 49, 19–27. [Google Scholar] [CrossRef] [Scilit]
  13. Bengtsson, P.; Berghel, J. Study of using a capillary tube in a heat pump dishwasher with transient heating. Int. J. Refrig. 2016, 67, 1–9. [Google Scholar] [CrossRef] [Scilit]
  14. Tewes, T.J.; Harcq, L.; Bockmühl, D.P. Use of Automatic Dishwashers and Their Programs in Europe with a Special Focus on Energy Consumption. Clean Technol. 2023, 5, 1067–1079. [Google Scholar] [CrossRef] [Scilit]
  15. Miao, Z.H. Study on the Drying Heat and Moisture Process and Performance of a Closed Heat Pump Dishwasher. Doctoral Dissertation, South China University of Technology, Guangzhou, China, 2020. [Google Scholar] [CrossRef]
  16. Shen, J.; Guo, T.; Tian, Y.; Xing, Z. Design and experimental study of an air source heat pump for drying with dual modes of single stage and cascade cycle. Appl. Therm. Eng. 2018, 129, 280–289. [Google Scholar] [CrossRef] [Scilit]
  17. Zajacs, A.; Bogdanovics, R.; Borodinecs, A. Analysis of low temperature lift heat pump application in a district heating system for flue gas condenser efficiency improvement. Sustain Cities Soc. 2020, 57, 102130. [Google Scholar] [CrossRef] [Scilit]
  18. Gatarić, P.; Širok, B.; Hočevar, M.; Novak, L. Modeling of heat pump tumble dryer energy consumption and drying time. Dry. Technol. 2019, 37, 1396–1404. [Google Scholar] [CrossRef] [Scilit]
  19. Wang, W.P.; Liu, H.C.; Fan, Y.F. Research on dishwasher energy efficiency trends and energy-saving technologies. In Proceedings of the 2020 China Household Electrical Appliances Technical Conference, Ningbo, China, 29–30 October 2026. [Google Scholar]
  20. Wang, W.P.; Liu, X.W.; Liu, S.S.; Liu, R.C.; Liu, H.C. Numerical study of heat transfer and energy consumption distribution in a dishwasher. In Proceedings of the 2022 China Household Electrical Appliances Technical Conference, Ningbo, China, 18–19 May 2023. [Google Scholar]
  21. Dong, W.; Li, Y. Economic and environmental benefits of a novel multi-functional heat pump system for dishwasher. E3S Web Conf. 2019, 118, 03029. [Google Scholar] [CrossRef] [Scilit]
  22. Yu, X.Y.; Wu, J.H.; Yu, X.Y. Study on drying characteristics of heat pump dishwasher based on association rules. J. Refrig. 2022, 43, 115–124. [Google Scholar]
  23. Liu, X.W.; Wang, W.P.; Liu, S.S.; Liu, R.C.; Liu, H.C. CFD study on convective heat transfer in dishwasher cavity. In Proceedings of the China Home Appliance Technology Conference, Ningbo, China, 18–19 May 2023. [Google Scholar]
  24. Tan, Y.B.; Zhang, L.F.; Zhong, Y.H.; Zhang, J.D. Study on airflow in household dishwasher with dual fan system. Appl. Home Appl. Technol. 2022, 64–67. (In Chinese) [Google Scholar]
  25. Helaly, H.O.; Awad, M.M.; El-Sharkawy, I.I.; Hamed, A.M. Theoretical and experimental investigation of the performance of adsorption heat storage system. Appl. Therm. Eng. 2019, 147, 10–28. [Google Scholar] [CrossRef] [Scilit]
  26. Li, M.F.; Wang, S.B.; Zeng, W.P.; Xu, S.R. Study on multi-mode fan ventilation drying technology for dishwashers. Appl. Home Appl. Technol. 2023, 3, 108–111. [Google Scholar] [CrossRef]
  27. Chen, R.J.; Chen, P.J.; Jiang, Y.X.; Lin, Z.P.; Duan, X.Y.; Jin, H. Study on the drying performance of dishwashers based on fan configuration. Househ. Appl. 2023, 11, 60–64. Available online: https://kns.cnki.net/kcms2/article/abstract?v=YsZ6lxCJneSB9SAELeCmFKYf8RoO2Lc4baKfZ44o97VszV4_ltnfjx6CDLEGryklLYwltQBCu_enSXkV-5EtI3wHHglGtix11ZjVzzW0gmpf2YJ275MRoAt9HB_o9XM5i7d29IhW6o9pvolbzYKkDC5t01xbZROsfudrstyKkig=&uniplatform=NZKPT (accessed on 12 November 2026).
  28. Yang, J.; Miao, Z.; Wu, J.; Yu, X.; Liu, C.; Liu, S. Dishwasher’s closed drying process investigation based on heat pump system. Energy Effic. 2023, 16, 45. [Google Scholar] [CrossRef] [Scilit]
  29. Xie, Y.; Wu, J.; Miao, Z.; Zhou, L.; Liu, S. Coupled investigation of dynamic moist air dehumidification and heat pump drying in a close-cycle dishwasher. Appl. Therm. Eng. 2025, 261, 125153. [Google Scholar] [CrossRef] [Scilit]
  30. Royer, Q.; Guibert, R.; Horgue, P.; Swadling, A.; Debenest, G. Air-water interface boundary condition for the numerical evaporation rate prediction of a horizontal water span under different convection regimes. Int. J. Heat Mass Transf. 2024, 226, 125438. [Google Scholar] [CrossRef] [Scilit]
  31. Wang, G.; Gu, L.; Li, Y.; Hou, P.; Huang, Q.; Shi, Z.; Liu, Y.; Ma, F.; Zhao, J. Optimization of guide plates and orifice plates on thermal management of battery energy storage system. Appl. Therm. Eng. 2024, 253, 123794. [Google Scholar] [CrossRef] [Scilit]
  32. Zhang, W.; Li, A.; Zhou, M.; Gao, R.; Yin, Y. Flow characteristics and structural parametric optimisation design of rectangular plenum chambers for HVAC systems. Energy Build. 2021, 246, 111112. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics