Abstract
Internal leakage directly affects the efficiency and positioning accuracy of electro-hydraulic proportional directional valves. This study establishes an annular-clearance leakage model incorporating eccentricity, pressure-dependent viscosity, and pressure-induced deformation, and develops a main-stage spool valve model in Simcenter AMESim 2021.1. Single-factor simulations and an L18 orthogonal design are used to investigate the effects of six key parameters. The results reproduce the approximately cubic dependence of leakage on clearance height and the theoretical 2.5-fold full eccentricity to concentric leakage ratio. Under controlled single-factor conditions, leakage increases with system pressure, clearance height, eccentricity ratio, and spool diameter, and decreases with valve lap magnitude and dynamic viscosity. The full L18 data yield the descriptive range order valve lap > eccentricity ratio > clearance height > dynamic viscosity > spool diameter > system pressure. An influence diagnostic shows that this ranking is sensitive to high-response runs and should therefore be treated as exploratory. The lowest leakage observed among the 18 simulations is 0.0008 L/min. These findings provide simulation-based guidance for parameter selection and leakage control in proportional valves.
1. Introduction
Electro-hydraulic proportional directional valves integrate directional control and proportional flow regulation and are widely used in construction machinery, precision machine tools, and agricultural equipment. Internal leakage causes energy loss, oil-temperature rise, and reduced control accuracy; severe leakage can produce actuator drift and accelerate component wear. Clarifying the leakage mechanism and the influence of structural, fluid, and operating parameters is therefore important for sealing design, energy efficiency, positioning accuracy, and operational reliability [1].
Previous studies have addressed hydraulic leakage from complementary perspectives. Yuan et al. [2] combined the Navier–Stokes equation with fractal theory to model end-face leakage and showed the importance of surface micro-morphology and machining accuracy. For spool valve clearance leakage, Chen et al. [3] coupled a stochastic zero-position leakage model with Kriging and Sobol analysis and identified radial clearance and throttling edge radius as influential parameters. Yan et al. [4] modeled annular and disc clearances in Valvistor proportional valves and showed that clearance width governs leakage and pressure gain characteristics. These studies establish the importance of clearance geometry but do not provide a directly comparable six-parameter analysis within one main-stage model.
Multi-physics and operating condition effects have also been investigated. Lv et al. [5] analyzed seal clearance and friction evolution under thermo-pressure coupling, whereas Xue [6] linked pressure, temperature, air content, and viscosity. Fan [7] examined contamination-sensitive micro-gap flow. Shi et al. [8] derived leakage equations for three friction pairs in a heavy-duty piston pump and reported experimental errors below 8%; that validation belongs to their pump study and is not validation of the present proportional valve model. He et al. [9] combined AMESim and an orthogonal design for neutral-position leakage and reported the order clearance height > overlap > eccentricity ratio. Jin [10] investigated ceramic grid plates and elastic metal seals under coupled pressure and temperature. Together, these studies motivate a transparent statement of the present model boundary, particularly its isothermal and simulation-only character.
Structural optimization studies have considered spool eccentricity, tilt, thermo-fluid-solid coupling, genetic algorithms, and alternative sealing channel geometries [11,12], while international work covers micro-gap flow, leakage prediction, wear and fault diagnosis, cavitation, transient spool forces, friction, and seal optimization [13,14,15,16,17,18,19,20,21,22,23,24]. Recent system-level studies further connect valve behavior with diagnosis and motion control: Dai et al. [25] developed simultaneous control valve fault diagnosis using feature fusion; Hou et al. [26] studied data-driven sliding-mode control for a magnetorheological fluid dual clutch; Liu et al. [27] proposed adaptive robust cascade control for a hydraulic secondary regulation drive; and Wang et al. [28] addressed hydraulic servomotor displacement control with disturbance compensation. These developments show that leakage predictions should be interpreted in relation to fault observability, closed-loop control, and positioning performance.
Accordingly, this study aims to quantify how system pressure, clearance height, valve lap, dynamic viscosity, eccentricity ratio, and spool diameter affect main-stage neutral-position leakage and the resulting open-loop cylinder drift. The study first derives concentric and eccentric annular clearance models and adds pressure viscosity and pressure-induced deformation corrections; it then implements a deliberately simplified AMESim main-stage model, performs controlled single-factor sweeps, and applies an L18 orthogonal design. The novelty claimed here is not the classical cubic clearance law or the 2.5-fold full eccentricity result themselves, but their integration with the two pressure corrections and a consistent six-parameter comparison that separates the lowest observed run from an unverified main effect optimum. The work is purely simulation-based and does not represent full-valve experimental validation.
2. Materials and Methods
2.1. Working Principle and Leakage Modes of Electro-Hydraulic Proportional Directional Valves
2.1.1. Working Principle of Electro-Hydraulic Proportional Directional Valve
Electro-hydraulic proportional directional valves play a central role in proportional control systems. The valve considered here comprises an upper two-stage pilot valve and a lower main valve. Figure 1 shows the pilot valve, main valve body, main spool, and centering springs. The pilot-stage pressure imbalance moves the main spool and establishes the required port connections; the subsequent leakage model isolates the annular clearance of the main stage.
Figure 1.
Schematic diagram of the electro-hydraulic proportional directional valve.
At the neutral position, the electrical signal is zero and the pilot spool valve remains at the neutral position. Control oil ports A and C communicate with the spring chambers of the main valve, resulting in equal pressure on both sides. The springs push the main valve spool to the central position, blocking all ports P, A, B and T, and the hydraulic cylinder is locked.
When operating at the left position, the electrical signal drives the pilot valve to move leftward, and the pilot spool moves accordingly. At this point, oil passage A communicates with the right spring chamber of the main valve and supplies pressurized oil, while oil passage C communicates with the left spring chamber and unloads to the return port T. The pressure on the right side of the main valve spool pushes the spool to move leftward, directing pressurized oil from port P to port A to drive the actuator, and the oil from port B flows back to port T. In this state, port P communicates with port B, and port A communicates with port T.
When operating at the right position, the electrical signal drives the pilot valve to move rightward, and the pilot spool moves accordingly. Oil passage C communicates with the left spring chamber of the main valve and supplies pressurized oil, while oil passage A communicates with the right spring chamber and unloads to the return port T. The pressure on the left side of the main valve spool pushes the spool to move rightward, directing pressurized oil from port P to port B to drive the actuator, and the oil from port A flows back to port T. In this state, port P communicates with port A, and port B communicates with port T.
The proportional characteristic of this valve is reflected in that the magnitude of the input electrical signal is proportional to the displacement of the pilot valve, which further determines the opening size of the main valve. This enables continuous and stable flow control, thereby precisely regulating the speed and direction of the actuator.
2.1.2. Leakage Forms and Main Leakage Path
Internal leakage in hydraulic transmission systems is influenced by machining and assembly quality, operating conditions, contamination, and valve geometry. A representative zero-opening spool valve pair is shown in Figure 2. Excessive clearance, eccentric assembly, seal damage, and contaminated oil can enlarge the leakage path and impair safety. Four broad leakage forms are commonly distinguished: clearance leakage, porous leakage, adhesive leakage, and dynamic leakage [29]. The present model isolates annular clearance leakage between the main spool and valve body.
Figure 2.
Schematic diagram of a zero-opening spool valve pair.
Clearance leakage is a common form of leakage in hydraulic systems, generally occurring between the mating surfaces of hydraulic components or sealing parts. It is mainly caused by excessive fit clearance, assembly errors, seal damage, oil contamination, temperature variations and other factors. Clearance leakage leads to reduced system efficiency, degraded control accuracy, increased temperature rise, and environmental pollution. With fit clearance as the main leakage pathway, it can be divided into dynamic and static types: dynamic leakage occurs when hydraulic components are in motion, while static leakage occurs when components remain stationary. Prevention and control measures include reasonable design of fit clearance, selection of high-quality seals, strict assembly processes, regular inspection and maintenance, and control of working temperature and oil quality. In addition, clearance leakage can be detected via pressure testing, oil analysis, visual inspection, temperature detection and other methods. Timely identification and resolution of clearance leakage problems are essential to ensure the efficient and stable operation of hydraulic systems.
Porous leakage in hydraulic systems refers to the flow of fluid from high-pressure zones to low-pressure zones through tiny, irregular channels. It is commonly observed when seals suffer from aging, wear, or insufficient machining accuracy. Its leakage mechanisms include permeation leakage through the microporous structure of materials, gap leakage through micro-clearances between mating components, and microcrack leakage caused by material fatigue or defects [30].
Numerous factors affect such leakage: the pressure difference is proportional to the leakage rate; lower fluid viscosity leads to easier leakage; larger, shorter and more regular pores result in greater leakage. In addition, the properties of sealing materials, ambient temperature, and aging and wear caused by long-term operation will all aggravate leakage. The hazards of porous leakage should not be underestimated: it reduces system efficiency, raises oil temperature, deteriorates positioning accuracy, and slows down response speed; external leakage causes environmental pollution, and severe internal leakage may even lead to component damage.
Adhesive leakage is governed by the interaction between oil properties and component surface conditions. High viscosity or low temperature promotes a thicker adhering oil film, while surface roughness and excessive clearance can retain and transport more oil. The U-shaped seal example in Figure 3 illustrates a sealing geometry in which surface contact and oil film behavior must be considered. In the present study, however, adhesive film transport is outside the modeled annular clearance mechanism.
Figure 3.
Schematic diagram of a U-shaped metal seal ring.
Dynamic leakage is mainly caused by the coupling effect of high-pressure driving and dynamic motion effects. High pressure inside and outside the system is the fundamental driving force of leakage, which forces oil into micro-clearances. The pumping effect generated by components during high-speed reciprocating or rotary motion actively draws oil into and out of the sealing interface. Furthermore, under dynamic operating conditions, mechanical loads, vibration or thermal expansion may cause instantaneous enlargement or eccentricity of the fit clearance. If seals fail due to hysteretic elastic compensation or frictional heating, they cannot fit the moving surface in real time. Combined with the throwing effect of centrifugal force generated by rotary motion on oil, multiple factors jointly cause oil to break through the sealing barrier under dynamic conditions and trigger leakage.
Leakage in hydraulic transmission systems is a complex process coupled by multiple factors such as assembly and machining, structural design, oil properties, and working environment [31]. The existence of fit clearance is the physical basis of leakage, while system driving pressure, dynamic motion effects, oil viscosity, and microscopic material defects are the main causes of the four leakage forms: clearance, porous, adhesive and dynamic leakage. Leakage will reduce system efficiency, cause inaccurate control precision, pollute the environment, and bring about serious equipment safety hazards. Therefore, to achieve efficient and stable operation of hydraulic systems, it is necessary to establish a comprehensive prevention and control system covering four aspects: structural optimization, strict control of machining and assembly accuracy, reasonable selection of seals and oil viscosity, and dynamic monitoring and post-maintenance, so as to minimize oil loss and leakage pathways.
2.2. Analysis of Leakage Theoretical Model
2.2.1. Leakage Model of Concentric Annular Fit Clearance
The fit clearance geometry used for the theoretical model is illustrated in Figure 4. Flow in the clearance can be pressure-driven, shear-driven by relative wall motion, or a superposition of the two. This section derives the annular clearance relations used to define and interpret the AMESim simulations.
Figure 4.
Schematic diagram of fit clearance.
Figure 5 shows the concentric annular clearance between the spool and valve body. The spool radius and diameter are and d, the valve body radius is , the radial clearance is , the axial clearance length is , and the inlet and outlet pressures are and , giving . The parallel plate relation is used as the starting approximation.
where is the clearance between the plates, is the pressure difference, is the plate width, is the clearance length, and is the dynamic viscosity. For the concentric annulus, the plate width is approximated by the circumference . This gives the pressure-driven leakage relation in Equation (2).
Figure 5.
Schematic diagram of concentric annular fit clearance between the spool and valve body.
Equation (2) describes pressure-driven leakage. When the spool moves axially relative to the valve body at the Latin symbol velocity , viscous shear produces an additional Couette flow component. The mean oil velocity associated with this component is , leading to Equation (3).
Combining the pressure-driven leakage term in Equation (2) with the Couette flow term in Equation (3), the total leakage flow rate through the concentric annular clearance between the moving spool and valve body is obtained as follows:
2.2.2. Leakage Model of Eccentric Annular Fit Clearance
When the spool is eccentric (Figure 6), denotes the dimensionless eccentricity ratio, denotes the eccentricity distance, and denotes the concentric radial clearance; thus . These symbols are used consistently below to distinguish a distance from its normalized ratio.
Figure 6.
Schematic diagram of eccentric annular fit clearance between the spool and valve sleeve.
For zero relative axial velocity , the pressure-driven leakage through the eccentric annular clearance is given by Equation (5).
where is the radial clearance under concentric assembly, is the eccentricity distance, is the pressure difference, is dynamic viscosity, is the clearance length, and is the spool diameter.
Equation (5) reduces to the concentric relation at and gives a leakage rate 2.5 times the concentric value at . This 2.5-fold ratio is an established consequence of the classical eccentric annulus relation; the contribution of the present work is its use within the corrected, six-parameter simulation framework rather than the derivation of a new eccentricity law.
Due to viscous resistance at the wall surface, the laminar flow velocity over the flow channel cross-section follows a parabolic distribution. This velocity profile cannot form immediately after fluid enters the flow channel; instead, it develops fully after passing through an inlet development length. Accordingly, the inlet laminar flow effect at the initial stage of the system must be considered in practical analysis. For the pressure-driven flow scenario with a stationary spool relative to the valve sleeve, Equation (2) is revised, as expressed in Equation (6).
where —correction coefficient, which is related to the Reynolds number , the matching clearance , and the length of the matching clearance. The correction coefficient is expressed as Equation (7):
where —correction coefficient.
2.2.3. Pressure Viscosity and Pressure Deformation Corrections
Pressure affects leakage both through viscosity and through elastic deformation of the spool valve clearance. The Barus relation in Equation (8) is adopted as a parsimonious isothermal approximation because it represents a monotonic pressure viscosity-dependence with one pressure viscosity coefficient and can be coupled directly to the clearance flow equation. It does not represent temperature-dependent viscosity or a full rheological model; therefore, its predictions are expected to be model-dependent in conditions where thermal effects or non-Barus behavior become important.
where is the dynamic viscosity at pressure , is the dynamic viscosity at the reference pressure, and is the pressure viscosity coefficient of the hydraulic oil.
The reference viscosity symbol in Equation (8) is distinct from the relative velocity symbol used in Equations (3) and (4).
Under the effect of pressure variation, both the valve spool and valve body bear corresponding hydraulic pressure, which further causes a certain change in the fit clearance between them. As shown in Figure 7a, the valve spool undergoes radial contraction under external pressure, resulting in a reduced diameter. An increase in pressure slightly raises the axial length of the valve spool. Meanwhile, the valve body expands in inner diameter under the outward internal pressure. The combined effect of these two factors ultimately widens the fit clearance between the valve spool and valve body. Therefore, when the operating pressure reaches a certain threshold, in-depth theoretical and simulation research must be carried out on the influence of pressure on the fit clearance.
Figure 7.
Pressure distribution and deformation schematic of the spool and valve body.
The stress characteristics and deformation laws of the thick-walled cylinder are analyzed. As shown in Figure 7b, for an arbitrary point selected within the cylinder wall, where r denotes the radial distance from the point to the central axis of the cylinder, the corresponding radial displacement at this position is expressed as Equation (9):
where —inner radius of the thick-walled cylinder; —outer radius of the thick-walled cylinder; —elastic modulus of the material; —Poisson’s ratio; —internal pressure acting on the inner wall of the cylinder; —external pressure acting on the outer wall of the cylinder.
The deformation of the spool and valve body under pressurization is derived from Equation (9). For the spool, which is subjected exclusively to hydraulic pressure, and are set to zero, and the nominal spool radius is taken as the characteristic dimension. As the spool and valve body experience identical working pressure, a uniform pressure p is employed, with its value set to one half of the pressure difference across the spool. Following simplification of Equation (9), the expression for the radial compression of the spool is presented as Equation (10):
The negative sign in the formula indicates the displacement direction of the spool, meaning that the spool undergoes radial displacement towards the central axis under pressure. For the valve body structure with , the displacement of the valve body at the nominal radius position can be derived by simplifying Equation (9):
where —equivalent outer diameter of the valve body.
By combining and deriving Equations (10) and (11), the relational expression describing the variation in the clearance between the spool and the valve body with pressure is given as Equation (12):
2.3. AMESim Model and Simulation Design
2.3.1. Model Scope and Structure
An electro-hydraulic proportional directional valve is represented in AMESim, but the model intentionally omits the pilot valve control stage and focuses on leakage through the main spool valve clearance. Standard hydraulic library and HCD library components are used to construct the main valve, hydraulic power source, and hydraulic cylinder shown in Figure 8. The pump and relief valve define the source conditions, the loaded cylinder represents the actuator, and a prescribed signal source sets main spool displacement. Consequently, the reported leakage is main-stage clearance leakage only: pilot-stage leakage, pilot/main-stage pressure coupling, and closed-loop position control are not included, so the model does not predict total leakage of a complete production valve.
Figure 8.
AMESim model of main-stage spool valve leakage.
2.3.2. Parameters and Numerical Procedure
Submodels are assigned to each hydraulic component in AMESim. BA0013 and BA0012 are used for the spool valve because they expose radial clearance, fillet radius, eccentricity ratio, and valve lap parameters. Other components use priority submodels. The baseline values are listed in Table 1; subsequent single-factor runs change one parameter at a time while retaining the remaining baseline settings.
Table 1.
Main parameters of the spool-valve leakage model.
3. Results
3.1. Leakage Characteristics Based on AMESim
The theoretical relations identify six principal variables: system pressure, clearance height, valve lap, dynamic viscosity, eccentricity ratio, and spool diameter. Their effects on main-stage leakage and open-loop cylinder displacement are evaluated by controlled single-factor simulations.
Each run lasts 10 s with a 0.1 s output interval. The commanded spool signal is zero so that the valve remains at neutral position and the leakage path is pressure-driven. The model is isothermal and contains no position feedback controller; cylinder displacement therefore represents cumulative open-loop drift within the simplified simulation, not normal closed-loop operation of a production system.
3.1.1. Influence of System Pressure on Internal Leakage
With the initial system pressure set to 10 MPa, leakage rate and pressure difference are plotted together. Figure 9 shows that the two quantities vary proportionally, consistent with Equation (2).
Figure 9.
Relationship between internal leakage and pressure difference.
For this run, the calculated clearance velocity is 2.2 m/s and the Reynolds number is 299.3, below the adopted critical value of 1100. This confirms internal consistency with the laminar flow assumption used by the model. It is a numerical consistency check, not experimental validation of the AMESim model.
With all other parameters held constant, the system pressure is set to 6, 8, 10, 12, 14 and 16 MPa, respectively. The pressure difference across the hydraulic spool valve is acquired using the batch run function of AMESim, as shown in Figure 10.
Figure 10.
Pressure difference across the hydraulic spool valve.
Figure 10 shows the finite-time evolution of the pressure difference across the main spool valve. The arithmetic in Table 2 has been recomputed from the reported peak and 10 s values. The corrected attenuation ratios are 34.9%, 40.0%, 31.8%, and 42.0% at 6, 10, 12, and 16 MPa, respectively. The ratios are not monotonic, particularly between 10 and 12 MPa. Because these values arise from a coupled transient response involving leakage, source pressure, and open-loop cylinder motion, they should not be interpreted as a monotonic material law. The present isothermal model contains no energy equation, so the previously stated thermal explanation is not supported; the non-monotonic trend requires confirmation by model reruns and experimental pressure measurements.
Table 2.
Pressure differences at different system pressures.
Figure 11 demonstrates the high sensitivity and dynamic coupling of the internal leakage rate of the hydraulic spool valve to system pressure under laminar flow conditions. Simulation data indicate that the temporal variation in the internal leakage rate is fully synchronized with the evolution of the pressure difference, with both reaching their peak values at 0.1 s and decaying smoothly thereafter. High-pressure operating conditions significantly intensify clearance leakage, as the leakage rate at 16 MPa is approximately 2.5 times that at 6 MPa. The synchronous decline of the leakage rate along with the decreasing pressure difference, combined with the uniform distribution of curves at each pressure level, confirms that the spool valve maintains structural stability within the simulated pressure range, its flow state is governed by linear laminar flow principles, and the system volumetric efficiency is predominantly controlled by the dynamic pressure difference. That is, the internal leakage of the spool valve exhibits strict pressure-difference dependence, and energy loss can be effectively controlled by selecting an appropriate system pressure.
Figure 11.
Internal leakage at different system pressures.
Figure 12 shows pressure-dependent open-loop cylinder drift. The displacement initially moves leftward and then rightward. As inlet pressure increases from 6 to 16 MPa, the reversal time is reduced from 2.9 to 2.2 s, and the 10 s displacement deviation increases substantially. These traces quantify the response of the simplified model without position feedback and should not be interpreted as the positioning performance of a controlled production actuator.
Figure 12.
Open-loop cylinder displacement at different system pressures.
3.1.2. Influence of Clearance Height on Internal Leakage
All other parameters are held constant while the clearance height is set to 0.01, 0.02, 0.03, 0.04, and 0.05 mm. Figure 13 and Figure 14 show the corresponding leakage rate and cylinder displacement responses.
Figure 13.
Internal leakage at different clearance heights.
Figure 14.
Open-loop cylinder displacement at different clearance heights.
Figure 13 shows that leakage increases nonlinearly with clearance height. In the controlled single-factor simulation, all parameters except clearance height are fixed. Thus, increasing the clearance from 0.01 to 0.02 mm gives the expected cubic ratio , whereas increasing it from 0.01 to 0.05 mm gives a theoretical ratio of 125. The B-level means in Table 3 are marginal averages across different combinations of pressure, valve lap, viscosity, eccentricity ratio, and spool diameter; their ratio is therefore not an isolated clearance height ratio and cannot be used to test the cubic law.
Table 3.
Factors and levels used in the orthogonal design.
As shown in Figure 14, the positioning stability of the hydraulic cylinder declines sharply with increasing clearance height, and there is an evident nonlinear positive correlation between displacement and clearance height. As the clearance height increases from 0.01 mm to 0.05 mm, the deviation of the hydraulic cylinder from its initial position becomes progressively larger. Under small clearance conditions of 0.01–0.02 mm, the displacement curve of the hydraulic cylinder is nearly horizontal, indicating excellent positioning retention capability. When the clearance increases to 0.05 mm, the displacement deviation reaches nearly 3 mm within 10 s due to the cumulative effect of internal leakage. The slope of the curve represents the drift velocity of the hydraulic cylinder. A larger clearance corresponds to a steeper slope and greater displacement deviation caused by internal leakage. The analytical results indicate that even a slight enlargement of the clearance leads to a cubic increase in leakage, which in turn causes continuous mechanical drift of the piston. Therefore, confining the clearance within the critical threshold of 0.03 mm is essential for preventing system instability and ensuring high-precision positioning control.
3.1.3. Influence of Valve Lap on Internal Leakage
All other parameters are held constant while the valve lap is set to −0.2, −0.5, −0.8, −1.1, and −1.4 mm. Figure 15 and Figure 16 show the leakage-rate and displacement responses.
Figure 15.
Internal leakage at different valve laps.
Figure 16.
Open-loop cylinder displacement at different valve laps.
Figure 15 shows that the −0.2 mm valve lap case has the steepest decay, whereas the −1.4 mm case remains comparatively flat. At t = 0.1 s, peak leakage increases from 0.0297 to 0.1906 L/min as the absolute valve lap decreases, an increase of approximately 6.4 times. The result indicates that reducing the sealing land overlap increases sensitivity to pressure fluctuations; however, the recommended lap must also satisfy flow response requirements and should not be selected from leakage alone.
As illustrated in Figure 16, under the small lap condition of −0.2 mm, driven by substantial internal leakage, the hydraulic cylinder generates a severe displacement of approximately 0.33 mm within 10 s, and the displacement velocity follows a divergent trend over time. By contrast, when the absolute value of valve lap increases to over 1.1 mm, the displacement curve exhibits outstanding stability with nearly negligible displacement. This confirms that valve lap is a core parameter governing the static stiffness of the system. For the design of high-precision position-holding systems, adequate valve lap must be ensured, with a recommended absolute value greater than 0.8 mm, to mitigate cumulative displacement errors arising from internal leakage.
3.1.4. Influence of Dynamic Viscosity on Internal Leakage
With other parameters fixed, dynamic viscosity is set to 0.025, 0.045, 0.068, 0.100, and 0.200 Pa·s. Figure 17 and Figure 18 show the corresponding leakage rate and cylinder displacement responses.
Figure 17.
Internal leakage at different dynamic viscosities.
Figure 18.
Open-loop cylinder displacement at different dynamic viscosities.
Internal leakage decreases as dynamic viscosity increases. At t = 0.1 s, increasing viscosity from 0.025 to 0.200 Pa·s reduces leakage from 0.1225 to 0.0182 L/min. The corrected reduction is (0.1225 − 0.0182)/0.1225 = 85.1%. This trend is consistent with the inverse-viscosity dependence of laminar clearance flow. Because temperature is not modeled, the result represents prescribed viscosity values rather than a prediction of thermal viscosity evolution.
Figure 18 indicates that low prescribed viscosity produces larger open-loop cylinder drift: at 0.025 Pa·s, the simulated 10 s deviation reaches approximately 0.21 mm, whereas the curves become much flatter at 0.100 Pa·s and above. This comparison illustrates the damping effect of viscosity within the isothermal model; practical oil selection must also consider temperature, efficiency, and response requirements.
3.1.5. Influence of Eccentricity Ratio on Internal Leakage
With other parameters fixed, the eccentricity ratio is set to 0, 0.2, 0.4, 0.6, and 0.8. Figure 19 and Figure 20 show the corresponding leakage rate and cylinder displacement responses. The eccentricity ratio is defined as the ratio of the valve core eccentricity to the unilateral radial clearance, with five values selected: 0, 0.2, 0.4, 0.6, and 0.8. The concentric condition serves as the baseline, and the upper limit of 0.8 prevents valve core contact failure and ensures the validity of the clearance flow model. Equally spaced sampling balances result visualization and computational efficiency, conforming to engineering practice and industry research conventions.
Figure 19.
Internal leakage at different eccentricity ratios.
Figure 20.
Open-loop cylinder displacement at different eccentricity ratios.
As can be observed from Figure 19, the internal leakage curves shift upward progressively with increasing eccentricity ratio, indicating that greater eccentricity gives rise to more severe internal leakage loss in the system. The internal leakage rate peaks at t = 0.1 s: it is 0.08096 L/min at an eccentricity ratio of 0, and surges to 0.15262 L/min at an eccentricity ratio of 0.8, corresponding to an approximately 88.5% increase in the maximum leakage rate. The leakage rate grows at an accelerating pace as the eccentricity degree rises. The leakage curve under high eccentricity ratio features a steeper downward slope over time, which means that under high-leakage conditions, the system pressure dissipates more rapidly, leading to a weaker capability to maintain stable pressure thereafter. In the design and assembly of hydraulic components, improving concentricity is the most critical technological measure to suppress leakage and enhance the volumetric efficiency and static holding performance of the system.
Figure 20 shows that increasing eccentricity reduces the position retention capability of the hydraulic system. As the eccentricity ratio increases from 0 to 0.8, the 10 s displacement drift increases from approximately 0.06 to 0.22 mm, corresponding to an approximately 3.7-fold final value, or a 267% increase relative to the concentric case. A high eccentricity amplifies displacement drift and reduces the static stiffness of the system; therefore, assembly concentricity should be carefully controlled.
3.1.6. Influence of Spool Diameter on Internal Leakage
With other parameters fixed, spool diameter is set to 8, 12, 16, 20, and 24 mm. Figure 21 and Figure 22 show the corresponding leakage rate and cylinder displacement responses. These spool diameter values of 8, 12, 16, 20 and 24 mm cover the mainstream engineering specifications of medium and small-sized electro-hydraulic proportional spool valves and conform to the standard size series of hydraulic valves. Five levels are set at equal intervals of 4 mm, which can directly verify the linear positive correlation between internal leakage and spool diameter, consistent with the annular gap leakage theory. This size range also ensures the validity of the laminar flow gap model, making the findings valuable for both theory and engineering practice.
Figure 21.
Internal leakage at different spool diameters.
Figure 22.
Open-loop cylinder displacement at different spool diameters.
Figure 21 shows an approximately linear increase in leakage with spool diameter, consistent with Equation (2). The peak leakage rises by about 0.027 L/min when diameter increases from 8 to 12 mm and by a similar amount from 12 to 16 mm; these are 4 mm increments. Larger diameters also produce faster post-peak pressure relief. Valve sizing must therefore balance flow capacity against the increased leakage perimeter.
Figure 22 shows the absolute piston position, with an initial value of 250 mm. At t = 10 s, the curve for the 24 mm spool reaches approximately 250.27 mm, corresponding to a displacement drift of approximately 0.27 mm relative to the initial position, rather than a displacement of 250.27 mm. The increasing drift with spool diameter indicates that a larger leakage perimeter reduces the pressure-holding capability of the simplified open-loop system.
3.2. Orthogonal Analysis of Leakage Factors
In this paper, an orthogonal experimental design is adopted to investigate the effects of various influencing factors on the leakage rate, providing reference for solving problems in practical engineering applications.
3.2.1. Orthogonal-Design Method
The orthogonal experiment is a widely used experimental design method for efficient analysis of multi-factor and multi-level problems. Based on the principle of orthogonality, it selects representative test points from full factorial experiments for analysis. The selected test points feature typical characteristics of uniform dispersion and neat comparability, and can represent the complete set of experiments. Thus, it is recognized as a highly efficient, time-saving and cost-effective experimental design approach [32].
The range analysis method is employed in this study to evaluate the sensitivity of each influencing factor. The range value reflects the impact of variations in each influencing factor on the target index. Calculation results indicate that a larger range value corresponds to a greater change in the experimental index when the factor is adjusted, meaning that a larger range signifies a more significant influence of the factor on the index and a higher sensitivity of the factor [33].
Based on the simulation of leakage characteristics, six main factors affecting the leakage rate are identified, namely system pressure, clearance height, valve lap, hydraulic oil viscosity, eccentricity ratio and spool diameter. Orthogonal experimental design is adopted to objectively and comprehensively analyze the relationship between each factor and the leakage rate [34,35,36].
3.2.2. Factor Levels and Simulation Runs
The six factors are system pressure (A), clearance height (B), valve lap (C), dynamic viscosity (D), eccentricity ratio (E), and spool diameter (F). Three levels are assigned to each factor as shown in Table 3.
The parameter levels are selected to cover the value ranges studied in the single-factor simulations and bracket the baseline working condition, rather than defining universal manufacturing tolerance limits. Specifically, pressure levels correspond to low, medium and high simulated supply pressures; clearance and valve lap levels range from tight to large and from small to large overlap, respectively; viscosity levels fall within the valid range of the adopted model; eccentricity levels cover concentric, mild and severe eccentricity states; and spool diameters span the size range of the studied valve components. The engineering applicability of these levels shall be verified in combination with specific valve types, oil grades, machining processes and actual duty cycles [37].
Based on the influencing factors listed in Table 3 and actual system operating conditions, an orthogonal test scheme is designed. For the six factors each with three levels, the orthogonal array is adopted, and 18 groups of simulations are run via AMESim to obtain corresponding leakage rates. In Table 4, columns A to F are factor columns, and the last column presents the leakage rate response instead of a seventh factor G. The K value denotes the mean response at each level of a factor, and the R value is the range between the maximum and minimum K values. The seventh column of the L18 array is reserved for error estimation and is not assigned to a factor; its K and R entries are therefore omitted from Table 4.
Table 4.
L18 orthogonal design runs and recalculated range analysis.
3.2.3. Range Analysis and Parameter Combinations
The full 18-run data give the range order C (0.4956) > E (0.3923) > B (0.3914) > D (0.3245) > F (0.3233) > A (0.2248). However, the leakage responses span from 0.0008 to 1.5919 L/min, a ratio of approximately 1990. Excluding the two extreme response runs, Tests 11 and 15, gives the robustness order E > B > A > F > C > D, with R values of 0.1819, 0.1612, 0.1378, 0.1125, 0.1019, and 0.0916, respectively. Valve lap consequently falls from first to fifth place. The full data ranking is therefore reported only as an exploratory result specific to this L18 data set and not as a universal sensitivity hierarchy. The controlled pressure sweep shows that leakage increases with pressure, whereas the marginal A-level means are . This reversed trend indicates strong combined factor, nonlinear, or interaction effects. Test 10 (A1B1C3D3E2F2) has the lowest leakage actually observed among the 18 runs (0.0008 L/min). Independently selecting the lowest marginal mean for each factor yields A3B1C3D3E1F1, but this combination was not simulated and contradicts the controlled pressure trend. It is therefore not interpreted as an optimum; a separate confirmation simulation and interaction-aware analysis are required.
4. Discussion
The single-factor simulations reproduce established clearance flow behavior: leakage increases approximately with the cube of clearance height, increases linearly with spool diameter, decreases with viscosity, and rises with eccentricity. These findings are consistent with the classical annular clearance relations and with prior reports emphasizing clearance and overlap [3,4,9]. They should therefore be treated as model consistency results, not as new physical laws. The value of the present study lies in evaluating all six parameters in one main-stage model and in connecting leakage to simulated open-loop displacement drift.
The orthogonal range analysis is sensitive to Tests 11 and 15 and does not provide a robust universal ranking. The cubic clearance dependence is supported by the controlled single-factor model but cannot be inferred from the marginal level means of the multi-factor orthogonal design. The range analysis is retained as exploratory screening evidence; confirmation simulations, interaction analysis, and preferably analysis of variance are required before a design optimum can be claimed.
The 0.01 mm clearance in the lowest observed run is a stringent nominal tolerance whose manufacturability and durability depend on grinding or honing capability, tolerance stack-up, contamination control, thermal expansion, and wear. The associated 16 mm spool is not inherently impractical, but the simulated leakage of 0.0008 L/min should not be presented as guaranteed production performance. Prototype measurements are required to establish achievable leakage distributions and cost–performance trade-offs.
Recent diagnosis and control studies [25,26,27,28] emphasize that leakage must ultimately be assessed in a closed-loop system with measurable fault signatures and realistic motion-control objectives. The present open-loop displacement traces are useful for sensitivity screening, but they do not demonstrate closed-loop positioning accuracy, fault diagnosis performance, or robustness to disturbances.
This study has four principal limitations. First, it is entirely simulation-based; the laminar regime check and comparison with trends reported in other studies are not substitutes for validation of this valve. Second, the pilot valve control stage is omitted, so pilot leakage and pilot/main-stage coupling are absent. Third, the Barus relation is used under an isothermal assumption and the model contains no temperature field, energy balance, temperature-dependent viscosity, contamination, wear, or long-term reciprocating motion. Fourth, the cylinder is simulated without position feedback, making the large drift values stress-case outputs rather than representative controlled operation trajectories. Future work should include prototype leakage and pressure measurements, a pilot/main-stage coupled model, thermal-fluid-solid coupling, confirmation runs for the proposed factor combination, interaction or variance analysis, and closed-loop displacement control.
5. Conclusions
- (1)
- The annular clearance model combines the established concentric/eccentric leakage relation with pressure viscosity and pressure-induced deformation corrections. It preserves the classical cubic clearance dependence and the 2.5-fold full eccentricity/concentric ratio.
- (2)
- In the AMESim main-stage model, leakage increases with pressure, clearance height, eccentricity ratio, and spool diameter and decreases with increasing valve lap magnitude and prescribed viscosity. The resulting cylinder displacement is an open-loop sensitivity indicator and requires closed-loop and experimental verification.
- (3)
- The full L18 data give the range order C > E > B > D > F > A. However, excluding Tests 11 and 15 changes the order to E > B > A > F > C > D, demonstrating that the ranking is sensitive to two extreme response runs. Test 10 has the lowest leakage actually observed among the 18 simulations, whereas A3B1C3D3E1F1 is only an unverified combination obtained from marginal level means.
- (4)
- The single-factor results provide simulation-based guidance for tolerance selection, valve lap design, oil viscosity selection, and spool sizing. The orthogonal analysis is treated as exploratory screening because its ranking is not robust to the extreme-response runs. Confirmation simulations, interaction analysis, manufacturability assessment, and experimental validation are required before quantitative design optimization.
Author Contributions
Conceptualization, J.X. and J.W.; methodology, J.X.; software, J.X. and Z.L.; validation, J.X., Z.L. and X.L.; formal analysis, J.X.; investigation, Z.L. and X.L.; resources, Z.F., S.C. and Y.L.; data curation, J.X. and Z.L.; writing—original draft preparation, J.X.; writing—review and editing, J.W. and Z.F.; visualization, Z.L. and X.L.; supervision, J.W.; project administration, J.W.; funding acquisition, Z.F. and S.C. All authors have read and agreed to the published version of the manuscript.
Funding
This research was funded by the Integrated Pilot Project for R&D, Manufacturing and Popularization and Application of Agricultural Machinery in Shandong Province (grant number SDNJYTH-202507), the Key Research and Development Program of Shandong Province (grant number 2024TSGC0754), and the Integrated Pilot Project for R&D, Manufacturing and Popularization and Application of Agricultural Machinery in Anhui Province (grant number 201).
Data Availability Statement
The original contributions presented in this study are included in the article. The AMESim model settings and raw simulation outputs supporting the reported results are available from the corresponding author upon reasonable request. No new physical test data were generated in this simulation-based study.
Conflicts of Interest
The authors declare no conflicts of interest. The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript; or in the decision to publish the results.
References
- Wang, P.F. Sealing Principle and Leakage Causes of Valves in Petrochemical Plants. Metall. Manag. 2022, 15, 43–45. [Google Scholar]
- Yuan, H.B.; Zhang, H.; Lian, Z.S.; Zhao, G.D. Fractal Study on Micro Sealing Mechanism of Hydraulic Valves. J. China Coal Soc. 2008, 6, 692–698. [Google Scholar]
- Chen, Z.C.; Ge, S.H.; Zhang, Z.L.; Zhu, Y.C. Distribution Model of Zero-Position Internal Leakage and Parameter Sensitivity Analysis of Spool Valve Pair. Acta Aeronaut. Astronaut. Sin. 2023, 22, 292–309. [Google Scholar]
- Yan, X.K.; Quan, L.; Hao, Y.X.; Liu, H.; Zhao, B. Simulation Analysis of Fit Clearance Leakage of Main Valve of Electro-Hydraulic Proportional Valve. Mach. Tool Hydraul. 2023, 51, 152–160. [Google Scholar]
- Lv, Y.D.; Chen, Y.L.; Cai, J.Y.; Liu, H.Y. Analysis and Experimental Study on Dynamic Sealing Characteristics of Hydraulic Spool Valve. Chin. Hydraul. Pneum. 2025, 29, 28–38. [Google Scholar]
- Xue, X.H. Analysis of Fluid Leakage Characteristics in Clearance of Hydraulic System. J. Mech. Eng. 2002, 6, 75–80. [Google Scholar]
- Fan, J.H. Study on Flow Field Characteristics and Clearance Leakage of Hydraulic Spool Valve for Integrated Transmission. Master’s Thesis, Beijing Institute of Technology, Beijing, China, 2016. [Google Scholar]
- Shi, J.Q.; Zhang, H.T.; Wei, K.C.; Li, X.Y.; Zhang, Q.Y.; Zhang, J. Leakage Characteristics of Heavy-Duty Piston Pump with Distributed Spherical Valve Plate and Inclined Piston. Chin. Hydraul. Pneum. 2022, 28, 123–151. [Google Scholar]
- He, Y.M.; Peng, L.K.; Song, F. Simulation Study on Neutral Internal Leakage of Hydraulic Spool Valve Based on AMESim. Chin. Hydraul. Pneum. 2018, 5, 72–80. [Google Scholar]
- Jin, G.N. Numerical and Experimental Study on Leakage Characteristics of Typical Contact Seals for Engines. Master’s Thesis, Shenyang Aerospace University, Shenyang, China, 2023. [Google Scholar]
- Zhang, B. Analysis of Leakage Characteristics and Structure Optimization of Hydraulic Spool Valve. Master’s Thesis, Chongqing University of Technology, Chongqing, China, 2021. [Google Scholar]
- Wang, Z.; Hu, Q.; Chen, Y.J.; Wang, Y.; Geng, J.X.; Shen, F.R. Leakage Characteristics, Sealing Mechanism and Optimal Design of Liquid Self-Impact Seal. CIESC J. 2025, 76, 2192–2202. [Google Scholar]
- Zhou, C.; Yang, H.Y. New Poiseuille-Couette Flow of Variable Viscosity Fluid in Micro Scale Gap Between Parallel Plates. In Proceedings of the ASME International Mechanical Engineering Congress & Exposition, Seattle, WA, USA, 11–15 November 2007. [Google Scholar]
- Mohammad, D.; Shashi, K.; Surendra, K. Exact Analytical Solutions for the Poiseuille and Couette-Poiseuille Flow of Third Grade Fluid Between Parallel Plates. Commun. Nonlinear Sci. Numer. Simul. 2012, 17, 1089–1097. [Google Scholar] [CrossRef] [Scilit]
- Baskharone, E.A.; Hensel, S.J. A New Model for Leakage Prediction in Shrouded-Impeller Turbo Pump. J. Fluids Eng. 1989, 111, 118–123. [Google Scholar] [CrossRef] [Scilit]
- Li, Z.L. Experimental Simulation of Piston Leakage in Axial Piston Pump. In Proceedings of the ASME International Mechanical Engineering Congress & Exposition, Orlando, FL, USA, 5–11 November 2005. [Google Scholar]
- Chen, Q.; Stoffel, B. CFD Simulation of a Hydraulic Servo Valve with Turbulent Flow and Cavitation. In Proceedings of the Computational Technologies for Fluid/Thermal/Structural/Chemical Systems With Industrial Applications, Volume 1; American Society of Mechanical Engineers (ASME): New York, NY, USA, 2024; pp. 197–203. [Google Scholar]
- Manring, N.D. Modeling Spool-Valve Flow Forces. In Proceedings of the ASME Fluid Power Systems and Technology Division, San Diego, CA, USA, 13–19 November 2004; pp. 23–29. [Google Scholar]
- Duan, S.Z.; Nielsen, T. Modeling and Analysis of Spool Valves with Eccentric Clearance. In Proceedings of the 5th Joint ASME/JSME Fluids Engineering Summer Conference, San Diego, CA, USA, 30 July–2 August 2007; pp. 1029–1034. [Google Scholar]
- Garcia, C. Comparison of Friction Models Applied to a Control Valve. Control Eng. Pract. 2008, 16, 1231–1243. [Google Scholar] [CrossRef] [Scilit]
- Frosina, E.; Senatore, A.; Buono, D. 3D CFD Transient Analysis of the Forces Acting on the Spool of a Directional Valve. Energy Procedia 2015, 81, 1090–1101. [Google Scholar] [CrossRef] [Scilit]
- Kudźma, Z.; Stosiak, M. Studies of Flow and Cavitation in Hydraulic Lift Valve. Arch. Civ. Mech. Eng. 2015, 2, 951–961. [Google Scholar] [CrossRef] [Scilit]
- Salant, R.F.; Homiller, S.J. The Effects of Shallow Groove Patterns on Mechanical Seal Leakage. Tribol. Trans. 1992, 35, 142–148. [Google Scholar] [CrossRef] [Scilit]
- Asok, S.P.; Sankaranarayanasamy, K.; Sundararajan, T.; Rajesh, K.; Ganeshan, G.S. Neural Network and CFD-Based Optimisation of Square Cavity and Curved Cavity Static Labyrinth Seals. Tribol. Int. 2007, 40, 1204–1216. [Google Scholar] [CrossRef] [Scilit]
- Dai, W.; Fan, R.; Nan, J. Simultaneous Fault Diagnosis for Control Valve Using Feature Fusion and Multilabel Classification Framework Considering Fault Similarity. IEEE Trans. Instrum. Meas. 2025, 74, 1–11. [Google Scholar] [CrossRef] [Scilit]
- Hou, M.; Zhao, J.; Tian, J.; Du, H. Minimum Operator-Based Data-Driven Sliding Mode Control for a Magnetorheological Fluid Dual Clutch. IEEE Trans. Cybern. 2025, 55, 4991–5001. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Liu, X.; Wang, Z.; Qiu, Z.; Jiao, Z.; Chen, X.; Nie, R. Cascade Control Method for Hydraulic Secondary Regulation Drive System Based on Adaptive Robust Control. ISA Trans. 2025, 156, 479–489. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Wang, Z.; Liu, X.; Qiu, Z.; Nie, R.; Chen, X.; Jiao, Z. Displacement Control Method of Hydraulic Servomotor Based on Swashplate Moment Disturbance Compensation. IEEE Trans. Autom. Sci. Eng. 2025, 22, 18570–18579. [Google Scholar] [CrossRef] [Scilit]
- He, D.J.; Wang, X.P. Hydraulic Leakage Control; Scientific and Technical Documentation Press Chongqing Branch: Chongqing, China, 1989. [Google Scholar]
- Zhan, C.C.; Fu, L.D.; Chen, X.Y. Hydraulic Reliability and Fault Diagnosis; Metallurgical Industry Press: Beijing, China, 2009. [Google Scholar]
- Tadeusz, D.; Paweł, S. Modelling Internal Leakage in the Automatic Transmission Electro-Hydraulic Controller, Taking into Account Operating Conditions. Energies 2023, 16, 7667. [Google Scholar] [CrossRef] [Scilit]
- Wu, B.; Chen, Z.; Li, J.M. Simulation Study on Performance of Spiral Groove Dry Gas Seal Based on CFD Orthogonal Experiment. Fluid Mach. 2012, 22, 11–16. [Google Scholar]
- Gao, X.F.; Shi, W.D.; Zhang, D.S. Optimal Design and Experiment of Vortex Pump Based on CFD Orthogonal Experiment. Trans. Chin. Soc. Agric. Mach. 2012, 25, 101–107. [Google Scholar]
- Li, R.C.; Wang, Z.B.; Xu, J.K.; Yuan, W.T. Design and Optimization of Hydraulic Slide Valve Spool Structure Based on Steady State Flow Force. Flow Meas. Instrum. 2022, 96, 102568. [Google Scholar]
- Wang, X.R.; Li, S.Z. Fluid-Thermal-Structure Coupling Simulation Analysis of Pilot Proportional Directional Valve. Chin. Hydraul. Pneum. 2022, 26, 22–28. [Google Scholar]
- Siwulski, T.; Warzyńska, U. Application of CFD Numerical Simulations and Shape Optimization to Modify the Flow Characteristics of Throttle Valves. Int. J. Fluid Power 2025, 25, 223–272. [Google Scholar]
- Ilyushin, Y.; Martirosyan, A.V.; Asadulagi, M.; Kukharova, T. Modeling and Optimization of an Automatic Temperature Control System for the Catalytic Cracking Process. Modelling 2026, 7, 68. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.