Skip to Content
ChildrenChildren
  • Article
  • Open Access

25 November 2026

13 Pages

Stereoacuity Assessment in Children: Testability, Repeatability, and Inter-Test Agreement Among TNO, Frisby and YRDS3 Stereotests

,
,
and
Beijing Tongren Eye Center, Beijing Key Laboratory of Ophthalmology and Visual Sciences, Beijing Tongren Hospital, Capital Medical University, Beijing 100730, China
*
Author to whom correspondence should be addressed.
Children2026, 13(12), 1648;https://doi.org/10.3390/children13121648 
(registering DOI)
This article belongs to the Special Issue Vision Disorders and Eye Care in Children

Highlights

What are the main findings?
  • TNO showed the highest initial testability in preschool children, while YRDS3 generally showed better test–retest repeatability across age groups.
  • Repeated assessments achieved more consistent measurements in younger children, while stereoacuity thresholds differed among the three tests.
What are the implications of the main findings?
  • Stereoacuity test selection in children should consider age, the ability to complete the task, and measurement repeatability; repeat assessment may be useful when initial responses are uncertain.
  • The same stereotest should be maintained during follow-up, as switching methods may introduce differences that could be mistaken for changes in binocular function.

Abstract

Background/Objectives: To identify the strengths of the TNO, Frisby, and YRDS3 methods for children of different school ages by comparing their testability, repeatability, and agreement. Methods: A total of 194 children aged 3–15 years were divided into preschool, lower primary, upper primary, and secondary groups. During a one-month period, each child completed the TNO, Frisby, and YRDS3 tests once during each of the three clinic visits. The testability, repeatability, and agreement of the three tests were compared with each other. Stereoacuity thresholds were log10-transformed for analysis. Repeatability between consecutive assessments was quantified using repeatability coefficients, and inter-test agreement was evaluated using Bland–Altman analysis with 95% limits of agreement. Results: Preschool testability differed among methods in R1 (p = 0.014), ranging from 80.9% for Frisby to 95.6% for TNO, and increased descriptively with repeated testing. TNO had the highest testability in preschool (95.6%) and lower primary (100.0%). All these 3 tests achieved 100% testability in the upper primary and secondary. YRDS3 had the best first-to-second assessment repeatability coefficients across age groups (0.164–0.317 log10 arcsec). Repeatability coefficients were generally lower for second-to-third assessment than for first-to-second assessment, particularly in younger children. Stereoacuity thresholds differed among the methods within each age group (all p < 0.001). Frisby had the lowest mean thresholds (32.2–47.6 arcsec). Bland–Altman analysis of the mean thresholds in first-to-third assessment showed differences. The 95% limits of agreement were narrowest for YRDS3-TNO (−0.380–0.159) log10 arcsec, followed by TNO-Frisby (−0.019–0.710) log10 arcsec and YRDS3-Frisby (−0.159–0.626) log10 arcsec. Conclusions: TNO demonstrated favorable initial testability in preschoolers, while YRDS3 generally showed higher repeatability. When initial responses are unclear, it could be helpful to repeat the evaluation. The same stereotest should be applied during follow-up because of the limited agreement between approaches.

1. Introduction

Stereopsis, the highest form of binocular vision, requires well-coordinated visual function from both eyes and proper cortical processing. It reflects the smallest detectable difference in depth that an individual can perceive and is typically expressed in seconds of arc [1]. Abnormal binocular visual function can lead to diplopia, visual fatigue, and impaired stereopsis, which may indicate conditions such as strabismus, amblyopia, anisometropia, or neurological disorders [2,3]. These conditions impose a substantial public health burden, with an estimated global prevalence of horizontal strabismus of 1.81% and a pooled prevalence of amblyopia in children of 1.36% [4,5]. Beyond impaired vision, these conditions are associated with difficulties in reading, eye-hand coordination, and everyday functioning, with consequences that may persist into adulthood [6,7]. Children with strabismus also report greater social anxiety, lower self-esteem, and poorer quality of life than those without strabismus [6].
Measurement of stereopsis is important but its feasibility in children depends on whether the child can understand and complete the task and whether the measurements are sufficiently repeatable for the clinical purpose. Currently, there is no perfect testing method; each method has its own advantages. The Frisby Stereotest (Stereotest Ltd., Thame, UK) [8] and the Lang Stereotest (LANG-STEREOTEST AG, Küsnacht, Switzerland) [9] encourage participation and do not require the use of polarized or red-green spectacles. In contrast, tests such as the Randot Stereotest (Stereo Optical Company, Inc., Chicago, IL, USA) [10] and Titmus Fly (Titmus Optical Co., Petersburg, VA, USA) [11] Test are based on polarized stimuli therefore needing polarized spectacles, and the TNO stereotest (Lameris Ootech BV, Nieuwegein, The Netherlands) [12] employs red-green anaglyphic stimuli and hence requires red-green spectacles.
In addition to the differences in testing methods, various stereotests assess different aspects of stereoscopic vision. Titmus and Randot circles measure local stereopsis through monocularly visible contours presented with polarized glasses [13]. TNO and Randot Preschool (Stereo Optical Company, Inc., Chicago, IL, USA) measure global stereopsis. The Frisby and Frisby–Davis Distance tests (FD2; Stereotest Ltd., Thame, UK) assess near and distance stereoacuity using physically displaced targets without dissociating glasses. Differences in stimuli, disparity levels, testing procedures, and participants’ comprehension contribute to variations in the measured thresholds [10]. Sensitivity, specificity, and testability also vary across tests and age groups [14,15,16,17]. A survey revealed that in the UK, US, and Canada, the most commonly used tests are Frisby (39%) and TNO (19%) [18]. In China, Yan’s Random Dot Stereotest Version 3 (YRDS3, People’s Medical Publishing House, Beijing, China), a commonly used tool for stereoacuity assessment, is a glasses-free random dot stereotest that uses column-interleaved display technology to present binocular disparity without monocular cues [19,20,21,22]. However, its performance has not been systematically compared with traditional tests such as the TNO and Frisby tests.
This study introduces the YRDS3 stereotest and comprehensively compares it with the TNO and Frisby tests in children. We evaluated their testability, repeatability, and agreement to determine the suitable method for preschool, lower primary, upper primary, and secondary children and how many time the test should be performed for these children to obtain a stable stereopsis result.

2. Materials and Methods

2.1. Participants

Children aged 3–15 years, willing to participate were recruited through community and from the pediatric ophthalmology department at Beijing Tongren Hospital from 1 January 2023 to 1 September 2023. Children with nil near stereopsis on two or more of the three tests (TNO, Frisby and YRDS3) at the first assessment, and organic or functional eye diseases currently under treatment have been ruled out. Sample sizes were according to previous pediatric stereotest studies [23,24,25]. All enrolled children underwent the same comprehensive ophthalmic examination to assess ocular health and determine whether further evaluation or treatment was indicated. Based on their school age, they were divided into preschool (3 years ≤ age < 6 years), lower primary (6 years ≤ age < 9 years), upper primary (9 years ≤ age < 12 years), and secondary (12 years ≤ age < 15 years) groups [22]. All participants completed the TNO, Frisby, and YRDS3 tests at each of the three follow-up visits—conducted in the community or at the hospital—within one month of their initial visit, with intervals of 5 to 7 days between visits. In addition to stereopsis testing, they underwent comprehensive ophthalmic examinations, including visual acuity, intraocular pressure, slit-lamp anterior and posterior segment examinations, refraction testing after dilation, axial length (AL), and strabismus screening. Written informed consent was obtained from the parents or guardians. The study followed the Declaration of Helsinki and was approved by the Institutional Ethics Committee (No. TRECKY2020-142).

2.2. Examination Protocol and Definitions

Age, sex and medical history were collected from the parents. Slit-lamp and fundus examinations are used to diagnose organic lesions of the anterior segment and the fundus. Each examination was performed by an experienced ophthalmologist or optometrist.

2.2.1. Refractive Examination, Axial Length and Strabismus Examination

Computerized and retinoscopic refraction were performed under bilateral cycloplegia (using 1% atropine ophthalmic gel [Shenyang Xingqi Eye Medicine Co., Ltd., Shenyang, China] for patients <6 years of age and 1% cyclopentolate hydrochloride eye drops [Shandong Bausch & Lomb Freda Pharmaceutical Co., Ltd., Jinan, China] for patients ≥6 years of age). A comprehensive refractometer (IS-400, Topcon Corporation, Tokyo, Japan) was used to determine the best-corrected visual acuity and spherical equivalent (SE) for each eye, defined as the spherical equivalent refraction (SE; SE = spherical power + cylinder power/2) [26,27]. The definition of amblyopia is according to the American Academy of Ophthalmology (AAO) ‘Clinical Practice Guidelines for Amblyopia’ [28]. After their refractive error has been corrected and their pupils have returned to normal, ocular biometry was measured using the Lenstar LS-900 (Haag-Streit, Bern, Switzerland), which automatically obtained three consecutive measurements per eye and determined AL. The Hirschberg test was used in combination with the cover-uncover and alternating cover tests to determine whether strabismus was present. Deviation angles were measured at a distance (6 m) and near (33 cm) using the alternate prism cover test.

2.2.2. Stereotests

Patients were required to have fully refractive correction when they performed stereotests. TNO and YRDS3 were conducted indoors under well-lit conditions on a Table 40 cm in front of the eyes. For Frisby, testing began at a viewing distance of 40 cm using the 6 mm plate, followed by the 3 mm and 1.5 mm plates. For children who correctly identified the target on the 1.5 mm plate, the viewing distance was progressively increased to 80 cm to assess finer stereoacuity. The same presentation and scoring procedure was maintained across all visits. All stereotests were administered by the same examiner at all three visits. The examiner used a new, blank recording form for each test and had no access to the child’s results from previous visits during testing. The order of the three stereotests was independently randomized for each child according to his or her comprehension and acceptance at each visit a 5-min rest interval was provided between consecutive stereotests.
TNO Stereotest (Figure S1A,B): Children wore red-green glasses and then were initially shown the screening plates I–III to determine whether they are stereoblinds. If they could not pass plates I–III, they were stereoblind and did not follow the next plate. Quantitative testing (plates V–Vl) was then performed using graded disparity plates. The children were asked to indicate the position of the missing sector within each disc. Testing began with the largest available disparity and proceeded to successively smaller ones. Stereoacuity was recorded in seconds of arc as the smallest disparity successfully identified. The TNO can measure stereoacuity ranging from 480 to 60 arcseconds.
Frisby Stereotest (Figure S1C,D): Except for the children’s own corrective glasses, the Frisby test does not require the use of any separating glasses, such as red-green or polarized glasses. Children were asked to point to the square containing the circle that appeared raised to its surroundings. Testing began with the thickest plate and progressed through presentations with smaller calibrated disparities. During the scored presentations, the plate was held perpendicular to the viewing axis, and the child’s head and plate remained stationary to minimize motion parallax. The plate was held slightly apart from the background to prevent any shading cues. The smallest successfully identified disparity was recorded in seconds of arc. The Frisby can measure stereoacuity ranging from 600 to 20 arcseconds.
YRDS3 Stereotest (Figure S1E,F): Children viewed the charts binocularly without any separating glasses. The qualitative test consisted of two plates. Children correctly identified the three-dimensional (3D) shapes on both plates to be considered free of stereoblindness. The quantitative assessment began with the largest disparity and proceeded through the available levels in descending order. At each level, the examiner presented the designated targets and recorded the child’s responses. Stereoacuity was recorded as the lowest disparity children identified. The YRDS3 can measure stereoacuity ranging from 800 to 40 arcseconds.

2.2.3. Testablity, Repeatability, and Agreement

Testability indicates Ntestable/N′(testable+untestable) (%), including numeric thresholds and stereoblind responses; failure to understand or cooperate with the task was classified as untestable. For the threshold analysis, each stereotest required a numerical result at all three visits. For each stereotest, R1, R2 and R3 denote the stereoacuity thresholds measured at the first, second, and third assessments, respectively. For each child with a numeric threshold at all three assessments, we calculated two differences on the log10 scale: the second threshold minus the first (R2 − R1) and the third threshold minus the second (R3 − R2). Repeatability was evaluated using the R2 − R1 and R3 − R2 differences in method-specific three-assessment complete cases. Repeatability was measured using repeatability coefficients (RC) [29], which were calculated as 1.96 times the standard deviation of differences, with chi-square-based 95% confidence intervals (CI). Between-method agreement was assessed using Bland–Altman (B–A) analysis within each age group and overall. For each child and stereotest, the three thresholds were log10-transformed and then averaged across assessments. Analyses included children with positive numerical thresholds at all three assessments for both methods in each comparison. For both the RC comparison of repeatability and the B-A analysis of agreement, only results with numerical values from all three measurements were selected; any test that was untestable or stereoblind, lacked numerical values, was excluded from the analysis. Mean bias was reported with t-based 95% CI, and 95% limits of agreement (LOA) were calculated as bias ± 1.96 standard deviations. Stereoblind and untestable responses were excluded from the agreement analysis. SD denotes the standard deviation of the difference in log10 stereoacuity thresholds in R2 − R1 or R3 − R2.
RC = 1.96 × SD Δ

2.2.4. Statistical Analysis

Statistical analyses were performed using SPSS version 26.0 (IBM Corp., Armonk, NY, USA) and Python version 3.12.14 (Python Software Foundation, Beaverton, OR, USA). Continuous variables are expressed as mean ± standard deviation or median (range), as appropriate. Age group comparisons used Welch’s one-way ANOVA for continuous variables and Pearson’s chi-square test for sex. Positive stereoacuity thresholds were log10-transformed, and back-transformed means were reported as geometric means. Within-age-group comparisons among methods used Friedman tests, followed by Wilcoxon signed-rank tests with Holm adjustment, restricted to children with numeric thresholds for all three methods. Paired comparisons used Cochran’s Q and exact McNemar tests with Holm adjustment. Between-age group comparisons used Fisher-Freeman-Halton exact tests. All tests were two-sided, with p < 0.05 considered statistically significant.

3. Results

A total of 194 children were recruited in this study, 68 in the preschool group, 65 in the lower primary group, 40 in the upper primary group, and 21 in the secondary group. Participant characteristics are summarized in Table 1. The male-to-female ratio in each group was close to 1:1, and there were differences in SE and AL across age groups.
Table 1. Participant characteristics.

3.1. Testability of the Three Stereotests

Table 2 summarizes the testability of the first assessment. In preschool children, the testability was 95.6% for TNO, 80.9% for Frisby, and 89.7% for YRDS3. Testability differed among the three methods (Cochran’s Q = 8.44, p = 0.014). In lower primary children, the testability was 100.0% for TNO, 92.3% for Frisby, and 96.9% for YRDS3, with no significant overall difference (p = 0.078). All three tests were completed in the upper primary and secondary groups at the R1 stage.
Table 2. Testability in the first assessment.
Table S1 shows that testability increased with repeated assessments in preschool children. At R2, the testability was 100.0% for TNO and 94.1% for both Frisby and YRDS3. At R3, it was 100.0% for TNO and YRDS3 and 98.5% for Frisby, respectively. Thus, some preschool children who could not complete a test at the R1 assessment subsequently completed it in R2 and R3, and the third assessment still increased successful YRDS3 and Frisby completions.

3.2. Repeatability Across Assessments

Figure 1 shows the repeatability trends for R2 − R1 and R3 − R2. The lower the RC value, the better the repeatability of the two tests. Overall, the RC for R3 − R2 was smaller than that for R2 − R1 across all age groups, except for the secondary group. The measurements for R3 and R2 were closer to each other than those for R2 and R1, and the RC for YRDS3 was smaller than that for TNO and Frisby in all age groups.
Figure 1. Repeatability in 3 assessments. (A–D) represent preschool, lower primary, upper primary and secondary respectively. Blue circles and orange squares indicate repeatability coefficients (log10 arcsec) for R2 − R1 and R3 − R2, respectively. Error bars represent 95% CI. R1, R2, and R3 denote the first, second, and third assessments.
Table S2 shows the repeatability in three rounds among the three tests. In preschool children, the RC values for R2 − R1 were 0.317 log10 arcsec for YRDS3, 0.392 for TNO, and 0.414 for Frisby. The RC values for R3 − R2 were smaller: 0.095, 0.133, and 0.238 log10 arcsec. TNO and Frisby thresholds were lower at R2 than at R1, with mean differences of −0.100 (95% CI, −0.153–−0.047) and −0.095 (−0.156–−0.034) log10 arcseconds, respectively. A similar reduction in repeatability was observed in younger primary children. The RC decreased from 0.164–0.094 log10 arcsec for YRDS3, from 0.327–0.171 for TNO, and from 0.301–0.266 for Frisby. YRDS3 had the smallest RC in both younger age groups. In the secondary group, the RC for YRDS3 was lower for R3 − R2 (0.089 log10 arcsec) than for R2 − R1 (0.185 log10 arcsec). It was slightly higher for the TNO and Frisby tests. Repeatability did not improve consistently with age.

3.3. Stereoacuity Thresholds and Agreement Between Methods

Within each age group, there were overall differences in the stereoacuity thresholds measured by the three methods (all p < 0.001). Age group differences were significant for YRDS3 and Frisby (both p < 0.001) but not for TNO (p = 0.145). The Frisby method had the lowest mean thresholds across all age groups, ranging from 32.2–47.6 arcsec (Table 3).
Table 3. Mean stereoacuity thresholds.
Figure 2 and Table 4 compare the mean log thresholds between the methods in R1–R3. Across all ages, the 95% LOA were narrowest for YRDS3–TNO (−0.380–0.159 log10 arcsec; width, 0.539), followed by TNO–Frisby (−0.019–0.710log10 arcsec; width, 0.729) and YRDS3–Frisby (−0.159–0.626log10 arcsec; width, 0.785). Mean biases were −0.111 log10 arcsec for YRDS3–TNO (95% CI, −0.132 to −0.089; n = 161), 0.345 for TNO–Frisby (95% CI, 0.316 to 0.375; n = 152), and 0.234 for YRDS3–Frisby (95% CI, 0.201 to 0.266; n = 150). Thus, YRDS3–TNO showed both the narrowest limits of agreement and the smallest absolute mean bias, whereas TNO–Frisby showed the largest absolute mean bias.
Figure 2. Bland–Altman agreement between stereotests based on mean log10 stereoacuity thresholds across three assessments in all age groups. For each child and stereotest, thresholds were log10-transformed and then averaged across R1–R3. (A) YRDS3–TNO; (B) YRDS3–Frisby; (C) TNO–Frisby. Solid horizontal lines indicate the mean bias; dashed lines indicate the 95% limits of agreement (mean bias ± 1.96 SD). Grey dotted lines indicate zero difference.
Table 4. Bland–Altman Agreement based on Mean log10 Stereoacuity Thresholds across Age Groups.

4. Discussion

Stereoacuity assessment is an important component of pediatric binocular evaluations. However, measured stereoacuity thresholds are influenced not only by binocular function but also by age-related cognitive ability, cooperation, and the characteristics of the stereotest itself. In this study, we compared the testability, repeatability, and agreement of TNO, Frisby, and YRDS3 in children in preschool, lower primary, upper primary, and secondary schools. TNO achieved the highest testability among younger children in the first assessment, particularly in the preschool and lower primary groups; repeated assessments improved stability, especially in younger children, and stereoacuity thresholds differed among methods, showing that results from different stereotests could not be directly exchanged during follow-up.
Testability is a key factor in pediatric stereopsis assessment because failure to complete a test does not necessarily indicate truly impaired binocular function. Successful testing requires sufficient attention, comprehension of the instructions, and cooperation. Previous studies have shown that testability increases with age. Read et al. evaluated the Randot Preschool stereotest in more than 1000 children and demonstrated high feasibility and an improvement in testability with age, 65% at 2 years and 92% at 3 years); however, quantitative threshold reliability was limited in younger age groups [30]. In the present study, TNO showed the highest first-assessment testability (95.6%) in preschool children, which is close to Read’s result for 3-year-olds. Similar age-related effects have been reported for other pediatric stereo tests [31,32]. Schmidt et al. evaluated the Random Dot E stereotest in 1257 preschool children and found that testability increased with age, from 86% at 3 years to 93% at 5 years during screening, and from 90% to 98% during the comprehensive examination [33]. At the first visit, 80.9% of preschool children could complete the Frisby stereotest, compared with 95.6% for the TNO. Saunders et al. [34]. introduced the Frisby task with a non-stereoscopic practice plate and used a sound to reward correct responses. With these changes, infants as young as 7 months were able to complete the test. TNO uses qualitative screening plates before quantitative testing, which may help younger children understand their tasks. Therefore, the TNO may be useful for obtaining measurable outcomes in young children.
Repeatability is essential when stereoacuity is used to monitor binocular development or treatment outcomes because longitudinal monitoring requires distinguishing true functional changes from measurement agreement. A previous study proposed that changes in stereoacuity should exceed the inherent measurement error before being considered clinically meaningful and reported that approximately two octaves of stereoacuity improvement could be considered to represent a real change [35]. Antona et al. evaluated four commonly used stereotests and demonstrated that repeatability varied substantially according to the binocular status and testing method. In subjects with normal binocular vision, the coefficients of repeatability were ±13 arcsec for Frisby and ±12 arcsec for Titmus, whereas in subjects with abnormal binocular vision, repeatability decreased markedly, with coefficients of repeatability of ±69 arcsec for Frisby and ±72 arcsec for Randot [10]. These findings indicate that a small change in stereoacuity during follow-up may represent a measurement fluctuation rather than a true functional improvement, particularly in children with impaired binocular function. McCaslin et al. compared a glasses-free digital stereotest, the ASTEROID test, on an autostereo 3D tablet with classic clinical tests, Randot Circles and Randot Preschool, and demonstrated good test-retest reliability, suggesting that simplified presentation methods may maintain measurement stability [29]. In our study, repeatability improved after repeated testing, especially in younger children, demonstrating a learning effect during stereotests. YRDS3 showed relatively good repeatability characteristics but not absolute superiority. YRDS3 applies column-interleaved display technology to present disparity under natural binocular viewing conditions [9,36,37]. The absence of additional dissociating devices may reduce task complexity and improve cooperation in children. Similar to Lang Stereopad, YRDS3 uses lenticular lens technology, established a standard for child-friendly designs that don’t require stereoscopic glasses [20].
The RC for all three tests in this study between R3 and R2 was lower than that between R2 and R1, indicating that as the number of tests increased, the measurement findings progressively stabilized. The preschool and early primary school groups showed a more noticeable trend, and children in these age groups may require additional testing because a single assessment might underestimate their true level of stereopsis. Overall, good repeatability may be associated with a clear testing principle, fine-graded classification of the threshold, convenient method of stimulus presentation, and a testing procedure that is easy to administer and understand. The spacing between adjacent disparity levels may also influence the RC of a stereotest. Between 40 and 100 arcsec, the YRDS3 provides four levels (40, 60, 80, and 100 arcsec), spaced 20 arcsec apart. For example, a one-level change from 60 to 80 arcsec on the YRDS3 corresponds to an absolute difference of 0.125 log10 arcsec, whereas a one-level change from 60 to 120 arcsec on the TNO corresponds to 0.301 log10 arcsec. When a child’s responses fluctuate between adjacent levels across visits, the finer spacing of the YRDS3 in this range may therefore contribute to the smaller R2 − R1 RC observed in our cohort.
When designing stereoscopic vision tests for children in the future, these factors should be considered to improve the reliability of the measurements and their applicability in children.
Differences in measurements between different tests affect whether their results can be directly compared or cross-referenced. Although stereopsis can be evaluated clinically using various methods, each test evaluates stereopsis differently; hence, it is important to assess the consistency of the data acquired from multiple procedures. Random-dot stereograms, including TNO and YRDS3, primarily evaluate global stereopsis by removing monocular cues, whereas Frisby evaluates depth perception using real depth targets without dissociating glasses [38,39]. Previous studies have demonstrated differences among stereotests, with Frisby frequently producing lower thresholds than random dot-based methods [17,30]. Fawcett et al. further demonstrated limited agreement between contour-based and random-dot stereotests, indicating that stereoacuity thresholds are influenced by stimulus characteristics and should not be directly compared across methods [40]. Our study is consistent with previous findings [25], Frisby achieved the lowest mean thresholds (32.2–47.6 arcsec). The lower geometric mean thresholds obtained with Frisby may partly reflect the finer disparities available with this test. Children who reached the finest disparity on TNO or YRDS3 could still obtain a lower numerical threshold on Frisby, so the differences in threshold in Table 3 should be interpreted in light of each test’s measurement range. YRDS3 and TNO had the best relative agreement among the three tests in our study, with the narrowest 95% LOA (LOA width of 0.539 log arcsec) and the smallest absolute value of the mean bias. This could be explained by the fact that both studies evaluated global stereopsis using random-dot stimuli. Nevertheless, a common stimulus is insufficient to ensure consistency in the measurement results. Converting the LOA width of the Bland–Altman analysis to arcseconds, YRDS3 might achieve results between 42 and 144 arcsec, while Frisby between 20 and 105 arcsec, assuming TNO measures a result of 100 arcseconds. In the two comparisons involving Frisby, the upper limits of the 95% consistency intervals exceeded 0.602 log10 units, meaning that the difference in thresholds measured by the two methods could exceed two octaves, which could indicate a clinical difference and may influence the assessment of stereopsis and its changes. To prevent misinterpretation of differences caused by the method change as an improvement or decline in stereopsis, it is important to be careful when changing stereotests during follow-up.
Of the 194 children in our cohort, 115 had strabismus, most commonly intermittent exotropia (90/115). The predominance of intermittent exotropia is relevant because all three tests assessed near stereoacuity. Children with intermittent exotropia may retain near stereopsis even when distance stereoacuity is reduced. In our cohort, 78 of 90 children with intermittent exotropia obtained a numerical threshold on all three tests at every visit, compared with 3 of 12 children with esotropia. Thus, children with intermittent exotropia were more fully represented in the three-test comparison than children with esotropia. This distinction also affects the results. A child who understood the task but had nil stereopsis was counted as testable. To contribute to a repeatability or agreement estimate, the child also needed a numerical threshold at each visit for the test or tests being compared. These estimates therefore describe children with consistently measurable near stereoacuity and have limited applicability to children with more severe binocular impairment.
This study has some limitations. First, the relatively small sample sizes in some subgroups (the upper primary and secondary group), which may affect the precision of the estimates and the robustness of statistical comparisons. Second, The high proportion of participants with strabismus, which may influence the findings and limit their generalizability to other pediatric populations. Third, The differences in the ranges and minimum measurable disparity thresholds of the stereopsis tests used, which may limit the direct comparability of the results. Finally, the YRDS3 is commonly used in China, although it was established based on the methodology of column-interleaved display, and further in-depth scientific research and validation are needed before it can be widely used.

5. Conclusions

Different stereotests provide different advantages for assessing stereopsis in children. The TNO may facilitate successful testing in younger children, whereas the YRDS3 showed stable repeatability characteristics in this cohort. The Frisby test remains valuable because of its glasses-free design and child-friendly procedure. It is recommended to use the same test during follow-up visits. An age-appropriate strategy for stereotest selection may improve the reliability of pediatric binocular stereopsis assessments.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/children13121648/s1, Figure S1: Test materials and representative stimuli of the TNO, Frisby, and YRDS3 stereotests; Table S1: Testability in R2 and R3; Table S2: Repeatability in three assessments.

Author Contributions

Conceived and designed the study, Y.Z., L.L. and J.F.; Methodology, Y.Z. and J.F.; Investigation, Y.Z.; Data Analysis, Y.Z. and L.L.; Writing—Original Draft Preparation, Y.Z.; Writing—Review and Editing, J.F. and J.H.; Supervision, J.F. All authors have read and agreed to the published version of the manuscript.

Funding

The study was supported by National Natural Science Foundation of China (82070998) and Training Program of high-level public health technical personnel Construction Project (Discipline Leader-02-10).

Institutional Review Board Statement

This study followed the tenets of the Declaration of Helsinki and was approved by the Ethics Committee of Beijing Tongren Hospital (Approved No. TRECKY2020-142, on 27 September 2020).

Data Availability Statement

The datasets generated and analysed during the current study are not publicly available due to the personal information of the participants but are available from the corresponding author on reasonable request.

Acknowledgments

We thank the children and their parents or guardians for their participation and cooperation in this study.

Conflicts of Interest

The authors declare no conflicts of interest.

Abbreviations

The following abbreviations are used in this manuscript:
LOAlimits of agreement
3DThree-Dimensional
ALAxial length
arcsecSeconds of Arc
ASTEROIDAccurate STEReotest On a mobIle Device
BStereoblind
B–ABland–Altman
CIConfidence Interval
DDiopter
ODOculus Dexter (Right Eye)
OSOculus Sinister (Left Eye)
R1First Assessment
R2Second Assessment
R3Third Assessment
RCRepeatability Coefficient
SDStandard Deviation
SESpherical Equivalent
YRDS3Yan’s Random Dot Stereotest Version 3

References

  1. Gautam Adhikari, P.; Shah, S.; Bhatta, N.; Mandal, P.; Sharma Paudel, B.; Pokhrel, A.; Koirala, B.; Shah, C.P. Stereoacuity among Undergraduate Medical and Nursing Students at a Tertiary Care Hospital: A Descriptive Cross-sectional Study. JNMA J. Nepal. Med. Assoc. 2022, 60, 54–58. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  2. Mehner, L.; Ng, S.M.; Singh, J. Interventions for infantile esotropia. Cochrane Database Syst. Rev. 2023, 1, Cd004917. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  3. Barry, S.R.; Bridgeman, B. An Assessment of Stereovision Acquired in Adulthood. Optom. Vis. Sci. 2017, 94, 993–999. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  4. von Bartheld, C.S.; Hagen, M.M.; Jiang, J.; Yang, W.; Agarwal, A.B. The global prevalence of horizontal strabismus: A systematic review and meta-analysis with a focus on ethnic variation. Surv. Ophthalmol. 2026, 71, 1803–1839. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  5. Hu, B.; Liu, Z.; Zhao, J.; Zeng, L.; Hao, G.; Shui, D.; Mao, K. The Global Prevalence of Amblyopia in Children: A Systematic Review and Meta-Analysis. Front. Pediatr. 2022, 10, 819998. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  6. Rakshit, A.; Schmid, K.L.; Majhi, D.; Webber, A.L. Visuo-Cognitive Executive Functions in Amblyopia and Strabismus: Associations With Function and Quality of Life. Investig. Ophthalmol. Vis. Sci. 2025, 66, 48. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  7. Kelly, K.R.; Pang, Y.; Thompson, B.; Niechwiej-Szwedo, E.; Drews-Botsch, C.D.; Webber, A.L. Functional consequences of amblyopia and its impact on health-related quality of life. Vision. Res. 2025, 231, 108612. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  8. Bohr, I.; Read, J.C. Stereoacuity with Frisby and revised FD2 stereo tests. PLoS ONE 2013, 8, e82999. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  9. Serrano-Pedraza, I.; Vancleef, K.; Read, J.C. Avoiding monocular artifacts in clinical stereotests presented on column-interleaved digital stereoscopic displays. J. Vis. 2016, 16, 13. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  10. Antona, B.; Barrio, A.; Sanchez, I.; Gonzalez, E.; Gonzalez, G. Intraexaminer repeatability and agreement in stereoacuity measurements made in young adults. Int. J. Ophthalmol. 2015, 8, 374–381. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  11. Garnham, L.; Sloper, J.J. Effect of age on adult stereoacuity as measured by different types of stereotest. Br. J. Ophthalmol. 2006, 90, 91–95. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  12. Vancleef, K.; Read, J.C.A.; Herbert, W.; Goodship, N.; Woodhouse, M.; Serrano-Pedraza, I. Overestimation of stereo thresholds by the TNO stereotest is not due to global stereopsis. Ophthalmic Physiol. Opt. 2017, 37, 507–520. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  13. Zhao, L.; Wu, H. The difference in stereoacuity testing: Contour-based and random dot-based graphs at far and near distances. Ann. Transl. Med. 2019, 7, 193. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  14. Tittes, J.; Baldwin, A.S.; Hess, R.F.; Cirina, L.; Wenner, Y.; Kuhli-Hattenbach, C.; Ackermann, H.; Kohnen, T.; Fronius, M. Assessment of stereovision with digital testing in adults and children with normal and impaired binocularity. Vision. Res. 2019, 164, 69–82. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  15. Mølgaard, I.L.; Biering-Sørensen, K.; Michelsen, N.; Elmer, J.; Rydberg, A. Amblyopia screening in kindergartens with tno stereotest. Acta Ophthalmol. 1984, 62, 156–162. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  16. Budai, A.; Czigler, A.; Mikó-Baráth, E.; Nemes, V.A.; Horváth, G.; Pusztai, Á.; Piñero, D.P.; Jandó, G. Validation of dynamic random dot stereotests in pediatric vision screening. Graefes Arch. Clin. Exp. Ophthalmol. 2019, 257, 413–423. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  17. Ohlsson, J.; Villarreal, G.; Abrahamsson, M.; Cavazos, H.; Sjöström, A.; Sjöstrand, J. Screening merits of the Lang II, Frisby, Randot, Titmus, and TNO stereo tests. J. AAPOS 2001, 5, 316–322. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  18. Vancleef, K.; Read, J.C.A. Which Stereotest do You Use? A Survey Research Study in the British Isles, the United States and Canada. Br. Ir. Orthopt. J. 2019, 15, 15–24. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  19. Li, S.; Zou, H.; Wei, C. Stereoscopic visual acuity in types of ametropic amblyopia in children. J. Pediatr. Ophthalmol. Strabismus 2014, 51, 105–110. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  20. Cao, L.Q.; Wang, Y.Q.; Gao, Y.; Zhou, B.Y.; Li, X.L.; Shen, K.Q.; Xu, B.; Li, M.G. A New Distance Stereotest by Autostereoscopic Display Using an Eye-Tracking Method. Front. Bioeng. Biotechnol. 2022, 10, 799744. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  21. Shi, Q.; Gu, Y.; Shi, D.; Zhou, M.; Li, H.; Zhang, H.; Li, H.; Hong, J.; Fu, J.; Wang, R.; et al. Evaluating the image quality and brain microstructural exploration of mean apparent propagator-MRI-a pilot study. BMC Med. Imaging 2026, 26, 402. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  22. Kang, E.Y.; Chong, Y.J.; Chen, K.J.; Chou, H.D.; Liu, L.; Hwang, Y.S.; Lai, C.C.; Wu, W.C. A comparative study of stereopsis in term and preterm children with and without retinopathy of prematurity. Graefes Arch. Clin. Exp. Ophthalmol. 2024, 262, 2685–2694. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  23. Tomaç, S.; Altay, Y. Near stereoacuity: Development in preschool children; normative values and screening for binocular vision abnormalities; a study of 115 children. Binocul. Vis. Strabismus Q. 2000, 15, 221–228. [Google Scholar] [PubMed]
  24. Schmidt, P.P.; Maguire, M.G.; Moore, B.; Cyert, L. Testability of preschoolers on stereotests used to screen vision disorders. Optom. Vis. Sci. 2003, 80, 753–757. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  25. Anketell, P.M.; Saunders, K.J.; Little, J.A. Stereoacuity norms for school-age children using the Frisby stereotest. J. AAPOS 2013, 17, 582–587. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  26. Fu, J.; Li, S.M.; Li, S.Y.; Li, J.L.; Li, H.; Zhu, B.D.; Yang, Z.; Li, L.; Wang, N.L. Prevalence, causes and associations of amblyopia in year 1 students in Central China: The Anyang childhood eye study (ACES). Graefes Arch. Clin. Exp. Ophthalmol. 2014, 252, 137–143. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  27. Li, J.; Liu, X.; Hao, J.; Zhou, F.; Li, H.; Zhao, Y.; Wang, Y.; Li, L.; Fu, J. Association between crystalline lens thickness and intermittent exotropia in children: A cross-sectional observational clinical study. Eur. J. Med. Res. 2025, 30, 389. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  28. Cruz, O.A.; Repka, M.X.; Hercinovic, A.; Cotter, S.A.; Lambert, S.R.; Hutchinson, A.K.; Sprunger, D.T.; Morse, C.L.; Wallace, D.K. Amblyopia Preferred Practice Pattern. Ophthalmology 2023, 130, P136–P178. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  29. McCaslin, A.G.; Vancleef, K.; Hubert, L.; Read, J.C.A.; Port, N. Stereotest Comparison: Efficacy, Reliability, and Variability of a New Glasses-Free Stereotest. Transl. Vis. Sci. Technol. 2020, 9, 29. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  30. Read, J.C.A.; Rafiq, S.; Hugill, J.; Casanova, T.; Black, C.; O’Neill, A.; Puyat, V.; Haggerty, H.; Smart, K.; Powell, C.; et al. Characterizing the Randot Preschool stereotest: Testability, norms, reliability, specificity and sensitivity in children aged 2–11 years. PLoS ONE 2019, 14, e0224402. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  31. Simons, K. A comparison of the Frisby, Random-Dot E, TNO, and Randot circles stereotests in screening and office use. Arch. Ophthalmol. 1981, 99, 446–452. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  32. Birch, E.E.; Salomão, S. Infant random dot stereoacuity cards. J. Pediatr. Ophthalmol. Strabismus 1998, 35, 86–90. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  33. Schmidt, P.; Maguire, M.; Kulp, M.T.; Dobson, V.; Quinn, G. Random Dot E stereotest: Testability and reliability in 3- to 5-year-old children. J. AAPOS 2006, 10, 507–514. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  34. Saunders, K.J.; Woodhouse, J.M.; Westall, C.A. The modified frisby stereotest. J. Pediatr. Ophthalmol. Strabismus 1996, 33, 323–327. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  35. Adams, W.E.; Leske, D.A.; Hatt, S.R.; Holmes, J.M. Defining real change in measures of stereoacuity. Ophthalmology 2009, 116, 281–285. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  36. Lang, J. A new stereotest. J. Pediatr. Ophthalmol. Strabismus 1983, 20, 72–74. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  37. Schmidt, P.P.; Kulp, M.T. Detecting ocular and visual anomalies in a vision screening setting using the Lang stereotest. J. Am. Optom. Assoc. 1994, 65, 725–731. [Google Scholar] [PubMed]
  38. Westheimer, G. The Ferrier Lecture, 1992. Seeing depth with two eyes: Stereopsis. Proc. Biol. Sci. 1994, 257, 205–214. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  39. Csizek, Z.; Mikó-Baráth, E.; Budai, A.; Frigyik, A.B.; Pusztai, Á.; Nemes, V.A.; Závori, L.; Fülöp, D.; Czigler, A.; Szabó-Guth, K.; et al. Artificial intelligence-based screening for amblyopia and its risk factors: Comparison with four classic stereovision tests. Front. Med. 2023, 10, 1294559. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  40. Fawcett, S.L. An evaluation of the agreement between contour-based circles and random dot-based near stereoacuity tests. J. AAPOS 2005, 9, 572–578. [Google Scholar] [CrossRef] [Scilit] [PubMed]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Article metric data becomes available approximately 24 hours after publication online.