Abstract
Thermal coupling among phase modules becomes a limiting factor as multiphase power converters move toward higher current and power density. This paper presents an electrothermal layout optimization framework for a four-phase Buck converter. First, an electrical loss model maps the converter operating point to phase-wise heat-source powers by accounting for RMS-current-dependent conduction loss, switching loss, gate-drive loss, and inductor loss. A thickness-averaged two-dimensional heat equation is then reduced to a thermal coupling matrix using a Green-function formulation and mirror heat sources for adiabatic lateral boundaries. The resulting matrix distinguishes self-heating from mutual thermal coupling and enables rapid temperature evaluation during layout optimization. An adaptive genetic algorithm minimizes normalized peak temperature and temperature dispersion, while enforcing geometric and non-overlap constraints. For a 48 V/12 V prototype operating at 30 A per phase, the optimized layout reduces the simulated peak temperature from 91.49 °C to 84.86 °C (a reduction of 6.63 °C) and the average temperature from 35.74 °C to 35.04 °C (a reduction of 0.70 °C). Infrared thermography gives a peak temperature of 86.8 °C at 25 °C ambient temperature, compared with approximately 91.5 °C before optimization. The reported optimized FEM peak is 84.86 °C. The proposed framework provides a physically interpretable and computationally efficient route for multi-hotspot thermal layout design in high-power-density converters.
1. Introduction
With the rapidly growing demand for compact high-current power supplies in electric vehicles, data centers, and industrial systems, multiphase interleaved converters are widely used to distribute current stress, reduce ripple, and improve modularity [1,2,3,4,5,6,7,8]. In a four-phase Buck converter, the 90° phase displacement shifts dominant ripple components to higher effective frequencies and reduces the electrical stress of individual branches, which is beneficial for both passive-component sizing and efficiency. However, the electrical advantages of phase replication are accompanied by increased component density and stronger electrothermal interaction between adjacent phases.
As power density increases, MOSFETs, gate drivers, and magnetic components form multiple spatially distributed heat sources whose temperature rises are not independent [9,10,11,12,13]. A device is heated not only by its own dissipation but also by lateral heat spreading from neighboring phases. Consequently, equal electrical current sharing does not necessarily produce equal junction temperatures when the layout, copper spreading paths, airflow, or interface conditions are asymmetric [10]. Local thermal coupling can, therefore, create a hotspot even when the total converter loss remains unchanged.
Conventional power-layout design is still dominated by experience-based placement followed by repeated finite-element verification [14,15]. FEA and CFD tools can accurately resolve detailed temperature fields [1,9,16,17,18], but directly embedding a full three-dimensional solver inside a global layout optimizer is computationally expensive. Genetic algorithms have been successfully applied to constrained thermal-layout problems because they do not require gradient information and can handle discontinuous geometric constraints [19,20]. Equivalent and mirror heat-source techniques further provide a route to replace repeated boundary-value solutions with analytical or semi-analytical temperature superposition [21].
Prior work on thermal placement follows two routes. One route evaluates a fixed arrangement with finite-element analysis, as in the multiphase converter study by Cao et al. [10]. The other places the solver inside the optimization loop, either directly [19] or through a trained surrogate [21]. The present framework takes a third route. The thermal response is analytical, the heat-source powers are generated by the converter loss model, and the layout is verified experimentally.
Compared with the equivalent-heat-source and autoencoder framework proposed by Yang et al. [21], the present method differs in three main aspects. First, the evaluator in (13)–(15) is a closed-form Neumann Green’s function with same-sign mirror sources, so no training set is required, and no surrogate has to be retrained when the source powers or the board outline change. Second, the source powers are not prescribed inputs to the placement problem. They are outputs of (4)–(9), which ties each source to the converter operating point. Third, the method is demonstrated on a 1.44 kW four-phase Buck converter with finite-element and infrared validation, rather than on a generic multi-source plate. Relative to the finite-element-in-the-loop formulation by Jeevan et al. [19], the analytical evaluator removes the solver from the fitness loop, which is what makes a population of 120 over 200 generations practical on a desktop computer.
The remaining challenge is to establish a direct quantitative chain from electrical operating conditions to heat-source power, from source positions to a coupled temperature field, and finally from the temperature field to a constrained layout objective. This work addresses that chain in three steps. First, a phase-resolved loss model is derived for the four-phase Buck converter and used to define physically consistent heat-source powers. Second, a thickness-averaged heat equation is transformed into a thermal coupling matrix in which diagonal terms represent self-heating and off-diagonal terms represent mutual thermal interference. Third, an adaptive genetic algorithm minimizes peak temperature and temperature dispersion while enforcing board-boundary and non-overlap constraints. MATLAB R2022b is used for rapid optimization, COMSOL Multiphysics 6.2 is used for detailed FEM verification, and infrared thermography is used for experimental validation.
The remainder of this paper is organized as follows. Section 2 establishes the converter operating point, passive-component design, and electrical loss model. Section 3 derives the reduced thermal model, mirror-source boundary treatment, and thermal coupling matrix. Section 4 formulates the constrained adaptive genetic algorithm. Section 5 compares the optimized and initial layouts using MATLAB and FEM simulations. Section 6 presents experimental thermal validation, and Section 7 summarizes the main conclusions.
The principal symbols used in the electrical loss analysis, reduced thermal model, and layout optimization are summarized in Table 1. Unless otherwise specified, SI units are used throughout.
Table 1.
The nomenclature of the principal parameters used in the electrothermal optimization framework.
2. Electrical and Thermal Source Foundations
2.1. Main Circuit Topology
The four-phase interleaved Buck converter shown in Figure 1 is used as the electrical platform for the thermal-layout study. The nominal input and output voltages are 48 V and 12 V, respectively. The total rated output current is 120 A, corresponding to 30 A per phase, and the switching frequency is 250 kHz. Adjacent phases are shifted by 90°, and the inductor-current ripple ratio of each phase is designed within 0.2–0.4. Each phase contains a high-side MOSFET, a low-side synchronous MOSFET, an output inductor, and a gate driver. An FPGA generates the interleaved gate signals, and the phase currents are sensed for current-sharing control. Defining the total output current as Io and the phase number as N = 4, the nominal phase current is Iph = Io/N = 30 A. This distinction is used consistently in the loss and thermal-source calculations below.
Figure 1.
A schematic of the main circuit topology of a four-phase Buck converter. The dashed red box marks one phase cell; the pink blocks represent the four voltage regulator modules (VRMs); the blue and green layers represent the compute die and the substrate, respectively; the arrows indicate the current flow and the heat-transfer path from the VRMs to the substrate.
Interleaving redistributes both electrical and thermal stress. Electrically, phase shifting reduces the amplitude of the summed current ripple and increases its effective ripple frequency. Thermally, however, the four phase modules remain coupled through the common substrate. The layout problem is, therefore, not equivalent to four independent single-phase designs: the temperature of one phase depends on the dissipation and location of all other phases. This electrothermal coupling is the principal quantity optimized in Section 3 and Section 4.
2.2. Key Parameter Design
For each Buck phase, the duty ratio is set by the output-to-input voltage ratio. Applying inductor volt–second balance gives the peak-to-peak current ripple, and defining the ripple ratio relative to the phase DC current yields the required inductance:
Substituting a 48 V input, a 12 V output, 30 A per phase, a 250 kHz switching frequency, and a 0.2–0.4 ripple ratio into (1) gives an inductance range of 3–6 μH. A 4.5 μH inductor (XAL1580-452ME, Coilcraft, Inc., Cary, IL, USA) is selected as an intermediate value, providing ripple margin without unnecessarily increasing magnetic volume or dc resistance. Here, r_I = ΔI_L/I_ph denotes the inductor-current ripple ratio.
A conservative lower bound for the local input decoupling of each phase can be obtained from the charge supplied during the high-side conduction interval:
where the voltage-ripple term in (2) denotes the allowed local input-voltage ripple. Equation (2) intentionally neglects ideal interleaving cancellation and, therefore, provides a conservative branch-level estimate. At the nominal duty ratio of approximately 0.25 with four evenly shifted phases, the dominant switching-current ripple at the common input can be strongly cancelled; in practice, the capacitor bank is still sized for phase mismatch, transient current, ESR/ESL, and PCB parasitics.
Accordingly, low-ESR/ESL ceramic capacitors are distributed close to the switching cells. Ten to twelve 10 μF ceramic capacitors are used in the prototype to provide both high-frequency current support and practical margin against dc-bias derating.
For a triangular phase-current ripple, the single-phase capacitive ripple relation gives the following conservative output-capacitance requirement:
Equation (3), again, does not credit perfect four-phase ripple cancellation; the actual summed ripple is lower when the four phase currents are well matched. Two to three 100 μF solid electrolytic capacitors are, therefore, combined with local ceramic decoupling to accommodate low-frequency ripple, load transients, and nonideal current sharing.
The UCC27282 gate driver is selected to meet the high-efficiency driving requirements of MOSFETs in the four-phase Buck converter. For the circuit’s switching frequency, the chip’s peak output capability of 2.5 A source current and 4 A sink current enables rapid gate-charge/discharge cycles, effectively reducing switching transition losses. Its wide supply range of 4.5 V–18 V accommodates various system voltage levels, while nanosecond-scale propagation delay ensures precise timing synchronization in four-phase operation, helping maintain the target ripple coefficient.
The power switching devices utilize the IQD009N06NM5CG N-channel MOSFETs, whose 60 V voltage rating satisfies the 48 V input voltage requirement with sufficient margin. The maximum on-resistance of 0.9 mΩ effectively minimizes conduction losses at 30 A per-phase output current. For the high switching frequency, the MOSFETs’ low gate-charge characteristics, combined with the UCC27282 driver’s capability, enable fast switching transitions to reduce switching losses.
2.3. Phase-Resolved Power-Loss Model
The thermal optimizer requires heat-source powers that are consistent with the converter operating point. For each phase, the dominant losses are the MOSFET switching and conduction losses, gate-drive loss, and inductor copper/core loss. For MOSFET k, a first-order switching-energy model is
where the additional terms represent MOSFET output-capacitance energy and reverse-recovery energy associated with the commutation path. When datasheet switching-energy curves are available, the bracketed term in (4) can be replaced directly by the measured turn-on and turn-off energies at the corresponding voltage and current. This form is retained here because it exposes the dependence on switching frequency, current, and transition time.
For continuous-conduction operation with an approximately triangular inductor ripple, the high-side and low-side MOSFET RMS currents are
which gives the temperature-dependent conduction loss
The MOSFET on-state resistances in (6) are evaluated at the junction temperature using the datasheet temperature coefficient. Retaining the triangular-ripple contribution to the RMS current is important because omitting it would systematically underpredict the heat-source power, particularly when the phase-current ripple is deliberately designed at 20–40%.
The gate-drive loss of the complementary MOSFET pair is
and the phase-inductor loss is represented by a dc-copper term plus a generalized Steinmetz core-loss term:
where the generalized Steinmetz coefficients, the peak-to-peak flux-density swing, and the effective core volume are obtained from the magnetic-core data. The phase-wise heat-generation power and total converter loss can then be written as
Equation (9) establishes the required electrical-to-thermal mapping. Losses physically concentrated within one phase are lumped into the corresponding phase heat source, whereas spatially distributed capacitor and control losses may be treated separately when needed. For the four-source validation case used in the layout study, the phase heat-source power assigned to the 10 × 10 mm source is 15.0 W, and the same value is used in the reduced model and in the finite-element model. The total phase electrical loss is 17.01 W, of which 15.0 W is assigned to the localized source. The total DC winding loss of the inductor is 3.42 W at 25 °C (3.8 mΩ, 30 A); only about 40–50% of this loss is transferred to the PCB, so 1.43 W enters the 10 × 10 mm source and 2.0 W is dissipated through the inductor package and included in the distributed losses described below. The source powers are, therefore, linked to the converter operating point rather than being arbitrary temperature-fitting parameters. The corresponding entry in Table 2 is, therefore, labeled as the PCB-coupled portion. The earlier label was imprecise, and the value used in the thermal calculation is unchanged.
Table 2.
Phase loss breakdown and the portion assigned to the 10 × 10 mm heat source at the nominal operating point (48 V input, 12 V/120 A output, 250 kHz).
Evaluating (4)–(9) at the nominal operating point of 48 V input, 12 V and 120 A output, 250 kHz, and 30 A per phase gives the phase loss breakdown in Table 2. The conduction terms use the on-state resistance at an estimated junction temperature of 100 °C, and the switching term uses the datasheet turn-on and turn-off energies at 48 V and 30 A. The total phase loss is 17.01 W, of which 15.0 W is assigned to the 10 × 10 mm source in both the reduced model and the finite-element model.
The measured full-load efficiency of 94.2% at a 1440 W output corresponds to a total converter loss of 88.7 W. The total phase electrical loss is 68.0 W, of which 60.0 W is assigned to the four sources. The remaining 28.7 W is not concentrated in the phase cells. It includes 8.0 W of choke winding loss, distributed over the four inductor packages, and 20.7 W, distributed over the input and output capacitor banks, the high-current copper, the connectors, and the auxiliary supply, over areas much larger than a 10 mm × 10 mm footprint. The reduced thermal model considers the four localized phase losses, while the additional distributed losses are included separately in the FEM model. Identical heat-loading conditions are maintained for the initial and optimized configurations. They are dissipated through separate paths in the capacitor bank, the connectors, and the auxiliary circuits, and they contribute to the background temperature rather than to the phase hotspots. Because both layouts receive the same 60 W, the comparison in Section 5 is made at equal heat input.
Accordingly, the reduced thermal model includes the four localized phase sources (60.0 W in total), whereas the FEM model additionally includes the 28.7 W distributed losses, resulting in a total heat input of 88.7 W. The same localized and distributed heat-source powers and thermal boundary conditions are used for the initial and optimized FEM cases.
3. Reduced Thermal Coupling Model
3.1. Thickness-Averaged Governing Equation
Because the substrate thickness is much smaller than its in-plane dimensions, the three-dimensional steady-state conduction problem is reduced by integrating through the substrate thickness [9,10]. Out-of-plane heat rejection is retained through an effective surface heat-transfer coefficient, while radiation is neglected. Defining temperature rise relative to ambient gives the thickness-averaged governing equation
where the coefficients in (10) represent the effective in-plane thermal conductivity, substrate thickness, and effective out-of-plane heat-transfer coefficient; the right-hand side is the areal heat-generation density. This form is dimensionally consistent and retains the competition between lateral heat spreading and surface heat rejection. The four lateral edges are treated as adiabatic symmetry boundaries:
The coefficients in (10) are effective properties of the substrate and its copper metallization, not bulk values of a single material. Their values and the resulting spreading length are listed in Table 3. The in-plane conductivity is obtained from a parallel mixture of the substrate and copper coverage, while the out-of-plane heat-transfer coefficient is determined using a natural-convection correlation for the horizontally mounted heated board. The air properties are evaluated at the film temperature, and the resulting coefficient is consistently applied in the reduced thermal model and the finite-element simulation. The reference temperature of the model is 20 °C, corresponding to the ambient boundary condition in the finite-element model. The measurements in Section 6 were conducted at a laboratory ambient of 25 °C, and all model–experiment comparisons are, therefore, expressed in terms of temperature rise above the respective reference temperatures.
Table 3.
Effective thermal properties and reference conditions of the reduced model.
The phase losses obtained from (9) are mapped to finite rectangular source regions rather than ideal point sources:
where the indicator function in (12) equals one inside a given heat-source footprint and zero elsewhere. The area integral of the source term over each footprint is exactly equal to the corresponding phase loss, so the mapping strictly conserves energy while linking electrical loss to physical source area.
3.2. Green-Function and Mirror-Source Formulation
For an infinite thickness-averaged plate governed by (10), the Green function of the modified Helmholtz operator is
where K0(·) is the modified Bessel function of the second kind, and λ is the thermal spreading length. A larger λ indicates stronger lateral thermal interaction before heat is removed by the out-of-plane cooling path. For a finite rectangular domain with adiabatic lateral boundaries, the zero-normal-flux condition in Equation (11) is enforced using same-sign mirror heat sources [21]. The Neumann Green function is approximated by
where each term corresponds to one same-sign mirrored position of source j. The image summation is truncated when the incremental temperature contribution becomes negligible. This construction replaces repeated boundary-value solutions by temperature-field superposition, while retaining the physical effect of the board boundaries. The construction is illustrated in Figure 2.
Figure 2.
A schematic of the (a) mirror heat-source construction and (b) equivalent multi-source representation used to enforce the thermal boundary conditions.
For layout optimization, the temperature assigned to heat source i is its area-averaged temperature. Averaging the Green function over both finite source areas avoids the point-source singularity in the self-heating term and produces the thermal-resistance matrix
In matrix form, the source-temperature vector equals ambient temperature plus the thermal-resistance matrix multiplied by the source-power vector. The diagonal matrix entries quantify self-heating, whereas the off-diagonal entries quantify mutual thermal interference between different phases. Layout optimization, therefore, has a clear physical interpretation: increasing thermal separation reduces the dominant mutual-coupling terms without changing the electrical load. For only four heat sources, evaluating this matrix is computationally inexpensive and, therefore, suitable for thousands of GA fitness evaluations, while COMSOL is reserved for detailed final verification.
The temperature Ti in (15) is the area average over the 10 mm × 10 mm footprint of source i, not the local maximum. Area averaging removes the logarithmic singularity of the Green function at the source centroid and matches a finite-element probe of finite size. The local peak inside a footprint is higher than Ti. The genetic algorithm minimizes Ti as a conservative surrogate for the hotspot temperature.
4. Constrained Adaptive Genetic Algorithm
4.1. Optimization Variables, Constraints, and Objective
The overall procedure of the constrained adaptive genetic algorithm is summarized in Figure 3. The center coordinates of the rectangular heat sources are used as the layout variables. For a general set of heat sources on a rectangular substrate, the real-valued chromosome is defined as
Figure 3.
The flowchart of the constrained adaptive genetic algorithm used for thermal-layout optimization.
Here, x_i and y_i are the center coordinates of heat source i, w_i and h_i are its width and height, W and H are the board dimensions, and N_h is the number of heat sources.
In addition to the board-boundary constraints in (16), any two source footprints are prohibited from overlapping. In the present case, the board is 100 mm × 100 mm and each source occupies 10 mm × 10 mm, so each source center is restricted to the interval 5–95 mm in both directions. Real-number encoding directly represents continuous placement coordinates without binary discretization. The 10 mm × 10 mm area is an equivalent heat-dissipation area, not the physical package footprint. The XAL1580-452ME package measures approximately 16.4 mm × 15.4 mm, and the portion of its winding loss not assigned to the localized source is distributed over the package, as described in Section 2.3.
The formulation above is deliberately thermal-only. The board outline, the source footprint, and the non-overlap condition are the constraints; interconnect length, parasitic inductance, EMI, and current sharing are not part of the fitness function. The optimizer is, therefore, a thermal-placement layer that is applied after the electrical topology, and the phase-cell designs are fixed. Its output is a thermal proposal that must be checked against the electrical design margins before it is accepted, and that check is not automated in the present version.
The thermal objective includes both hotspot suppression and temperature uniformity. From the source temperatures predicted by (15),
and the normalized multi-objective cost is defined as
The temperature limit is 85 °C. The weights assigned to the peak temperature, temperature uniformity, and the overlap penalty are 1, 0.5, and 150, respectively. Because the first two terms are normalized by the allowable temperature rise, their relative weighting is not distorted by units; the large dimensionless overlap penalty makes geometrically infeasible layouts noncompetitive.
4.2. Population Evolution and Adaptive Parameters
The population size is 120. The initial coordinates are sampled from a normal distribution centered at (50 mm, 50 mm) with a standard deviation of 5 mm and then clipped to the feasible board region, intentionally representing a thermally clustered initial design. Tournament selection with k = 3 chooses the individual with the lowest cost J from each sampled group. Elitism preserves the best solution found so far, while single-point crossover and Gaussian coordinate mutation generate new candidate layouts [19,20].
To make the adaptive strategy explicit, rather than relying on fixed crossover and mutation probabilities, both probabilities are linked to the normalized dispersion of the population cost. The adaptive law is
The crossover probability is bounded between 0.70 and 0.90, the mutation probability between 0.05 and 0.30, and the diversity scale is 0.05. The normalized diversity is Dn = min(1, σ(J)/(0.05 μ(J))), and the two probabilities are pc = 0.70 + 0.20 Dn and pm = 0.30 − 0.25 Dn. At high diversity (Dn = 1), recombination is favored, with pc = 0.90 and pm = 0.05. As the population converges (Dn → 0), crossover is suppressed, and mutation is promoted, with pc → 0.70 and pm → 0.30. Gaussian mutation uses a coordinate standard deviation of 2 mm, followed by boundary projection and overlap checking.
The maximum generation count is 200. In routine optimization, early termination is allowed when the best peak temperature improves by less than 0.1 °C over 20 consecutive generations. For the convergence plot, the run is intentionally continued to 200 generations to show the asymptotic behavior of the algorithm.
5. Numerical and Simulation Results
5.1. Genetic Algorithm Optimization in MATLAB
The reduced thermal model in (15) is used as the temperature evaluator inside the GA. The population size is 120, and the convergence run is extended to 200 generations. Crossover and mutation are bounded by the adaptive law in (19), with probabilities approaching 0.70 and 0.30 as the population converges. The convergence plot reports the best maximum source temperature rather than the dimensionless cost J so that the convergence has a direct physical interpretation.
Figure 4 shows the spatial temperature field associated with the final GA candidate. The four source regions are distributed toward different corners of the allowable domain, rather than concentrated near the center. The resulting longer heat-spreading distances reduce mutual heating. As shown in Figure 5, the best maximum temperature decreases rapidly from approximately 83.5 °C during the early generations and gradually approaches about 80.5 °C. Most of the improvement occurs during the first several tens of generations, and the curve becomes nearly asymptotic after approximately 70–80 generations. Continued iterations to generation 200 produce only marginal change, indicating stable convergence. The analytical evaluator is intentionally simplified and is used primarily to rank candidate layouts; the final temperature values are, therefore, verified using the higher-fidelity FEM model.
Figure 4.
The predicted temperature distribution for the optimized four-source layout obtained using the reduced thermal coupling model.
Figure 5.
Convergence of the best maximum source temperature over 200 generations of the adaptive genetic algorithm.
The difference between the reduced-model prediction and the FEM result reflects the geometric detail and boundary conditions represented in the two models.
5.2. Finite Element Thermal Simulation Analysis
The FEM temperature distributions in Figure 6 and Figure 7 compare the initial and optimized phase arrangements. The clustered initial layout produces strong mutual thermal coupling and a peak temperature of 91.49 °C, with an average substrate temperature of 35.74 °C. After optimization, the peak decreases from 91.49 °C to 84.86 °C, a reduction of 6.63 °C, while the average decreases from 35.74 °C to 35.04 °C, a reduction of 0.70 °C. Source redistribution reduces mutual-heating contributions while maintaining the same total applied heat-source power.
Figure 6.
The FEM temperature-field distribution of the initial four-phase layout before optimization. The color scale refers to the 20 °C reference temperature of the model.
Figure 7.
The FEM temperature-field distribution of the optimized four-phase layout. The color scale refers to the 20 °C reference temperature of the model.
For a consistent comparison with the infrared measurements, the FEM peak temperature is extracted from the same 10 mm × 10 mm heat-source footprint and the corresponding exposed surface. Thus, the FEM and infrared results represent the local maximum temperature within the same physical region, whereas the area-averaged source temperature used by the genetic algorithm is evaluated separately.
The finite-element peak of 84.86 °C is a nodal maximum, whereas the convergence curve in Figure 5 reports the area-averaged source temperature Ti defined in (15). The two quantities differ by the intra-source gradient and are not directly comparable.
Figure 6 illustrates the initial arrangement, in which heat-spreading regions overlap near the interior of the substrate. In Figure 7, the four source regions are more widely separated, mitigating hotspot accumulation. As indicated by the off-diagonal terms of the thermal coupling matrix in (15), this separation lowers mutual thermal interference without requiring a reduction in the phase-loss inputs.
5.3. Comparison with a Fixed-Parameter Genetic Algorithm
To isolate the effect of the adaptive schedule, the same objective, constraints, population size, and evaluation budget were used in a second set of runs with fixed probabilities pc = 0.80 and pm = 0.30. Thirty independent runs were performed for each schedule, with paired random seeds. Table 4 reports the final cost, the peak area-averaged source temperature, and the number of generations needed to satisfy the stagnation criterion. A run is terminated when the best peak temperature improves by less than 0.1 °C over 20 consecutive generations, or when 200 generations are reached.
Table 4.
Statistical comparison of adaptive and fixed-parameter genetic algorithms over 30 paired runs.
As shown in Table 4, the adaptive genetic algorithm achieves a lower objective value of 0.9308 and a peak area-averaged source temperature of 80.50 °C, compared with 0.9638 and 82.65 °C for the fixed-parameter algorithm. The adaptive approach also reduces the average number of generations required to reach the stagnation criterion from 120 to 90, corresponding to a 25% reduction. Furthermore, the standard deviation of the final objective value decreases from 0.004 to 0.002, indicating improved convergence consistency across independent runs. These results demonstrate the effectiveness of the adaptive crossover and mutation strategy in improving both optimization performance and convergence efficiency. The difference in the best objective value (0.033) is more than eight times the standard deviation of either schedule, and the run-to-run standard deviation is halved, so the improvement is statistically meaningful.
6. Experimental Results
To assess the practical feasibility of the optimized phase arrangement, the initial and revised four-phase hardware configurations are compared in Figure 8 and Figure 9. The photographs identify the four phase locations in each arrangement. In the revised fixture, the phase regions are distributed with greater spatial separation, thereby alleviating concentrated heating in the central part of the assembly. The steady-state infrared measurements in Figure 10 and Figure 11 provide a direct qualitative and quantitative comparison of hotspot locations and peak surface temperatures. The FEM calculations are reported separately in Figure 6 and Figure 7.
Figure 8.
A photograph of the four-phase experimental fixture before thermal-layout optimization, showing the original phase placement.
Figure 9.
A photograph of the experimental fixture after thermal-layout optimization, showing increased separation among the phase regions.
Figure 10.
Infrared thermography of the four-phase converter before layout optimization (indicated peak: approximately 91.5 °C). The reported value is the local maximum within the source footprint.
Figure 11.
Infrared thermography of the four-phase converter after layout optimization (indicated peak: approximately 86.8 °C). The reported value is the local maximum within the source footprint.
The thermal measurements were performed on the operating converter rather than on an equivalent heater. The four-phase cells in Figure 8 and Figure 9 are populated with the MOSFETs, gate drivers, and inductors listed in Section 2.2, and the converter delivers 12 V at 120 A into a Chroma 63206A-60-1000 programmable DC electronic load (Chroma ATE Inc., Taoyuan, Taiwan, China) from a Chroma 62150H-100P programmable DC power supply (Chroma ATE Inc., Hsinchu, Taiwan, China) at 48 V. The four heat sources of the model correspond to these four cells, and each 10 mm × 10 mm footprint covers the MOSFET pair and the inductor of one phase.
The board was mounted horizontally in still air at a laboratory ambient temperature of 25 ± 1 °C. No forced airflow or cold plate was used. Infrared images were recorded with an HIKMICRO H21ProS+ handheld thermal imager (Hangzhou Microimage Software Co., Ltd., Hangzhou, China), equipped with an uncooled 256 × 192 microbolometer detector (512 × 384 after ISR super-resolution), a noise-equivalent temperature difference of 0.05 K, and an accuracy of ±2 °C, positioned 400 mm above the board. The emissivity was set to 0.95 after the MOSFET and the inductor surfaces were covered with matte tape of known emissivity. The converter was operated at full load until the peak temperature changed by less than 0.2 °C over 5 min, which required approximately 30 min from a cold start. Three images were then recorded at 1 min intervals. The peak values of the three images differed by less than 0.3 °C, and the reported values are their means. The same load, ambient, and cooling conditions were used for both boards, and the two boards use identical components.
The initial infrared image in Figure 10 indicates a peak temperature of approximately 91.5 °C, whereas the optimized configuration in Figure 11 reaches approximately 86.8 °C. This corresponds to a measured peak reduction of roughly 4.7 °C (approximately 5.1% relative to the initial peak), consistent with the direction of the FEM-predicted improvement. The infrared display range extends down to approximately 34.5 °C. The finite-element model uses a reference temperature of 20 °C, whereas the experiment was performed at 25 °C. The comparison is, therefore, made on temperature rise, and the relative deviation is evaluated as
Using the optimized infrared peak of 86.8 °C, the finite-element peak of 84.86 °C, and the two reference temperatures of 25 °C and 20 °C in (20) gives a temperature-rise deviation of approximately 4.95% relative to the measured temperature rise. Differences between the measurement and simulation may arise from three-dimensional spreading, local convection, emissivity settings, thermal contact resistance, and temperature-dependent material properties. The measured peak-temperature reduction is consistent with the finite-element trend. The 0.3 °C scatter of the three recordings characterizes short-term repeatability, not absolute accuracy. The camera accuracy is ±2 °C, and the emissivity setting contributes a further uncertainty. The 4.95% deviation corresponds to 3.06 K, which is of the same order as the combined uncertainty; the comparison is, therefore, interpreted as consistency within experimental uncertainty rather than as a precise validation.
Figure 12 compares the measured conversion efficiencies of the four-phase Buck converter before and after layout optimization under a 48 V input and 12 V output. Both configurations exhibit increasing efficiency at light loads, followed by a gradual decrease as the output current increases. The optimized layout achieves a peak efficiency of 96.8% at approximately 30 A and maintains 94.2% efficiency at the rated output current of 120 A, 0.52 percentage points above the original layout. The efficiency was measured with a calibrated power analyzer, and the uncertainty of the full-load value is estimated at ±0.1 percentage points, so the difference is above the measurement uncertainty.
Figure 12.
The measured conversion efficiency of the four-phase Buck converter before and after thermal-layout optimization under a 48 V input and 12 V output.
The efficiency improvement cannot be attributed to the thermal change alone. Using the measured 4.7 K reduction in peak surface temperature as an estimate of the junction-temperature change, and a MOSFET on-state-resistance temperature coefficient of 0.4% K−1, the corresponding reduction in conduction loss is estimated to be approximately 0.03 W per phase, or 0.1 W in total. At an output power of 1440 W, the measured efficiencies of 93.68% and 94.20% correspond to total converter losses of 97.15 W and 88.66 W, respectively, yielding a loss reduction of approximately 8.49 W. Therefore, the temperature-dependent conduction-loss reduction accounts for only about 1.2% of the observed improvement. The phase relocation also changes the length of the high-current copper between the input capacitor bank and the phase cells, as well as the commutation-loop inductance. These contributions were not separated experimentally, and the measured efficiency improvement is, therefore, reported as the combined effect of the layout change.
7. Conclusions
This paper presents a physics-based multi-hotspot layout optimization framework for a four-phase high-power Buck converter. A phase-resolved loss model first maps electrical operating conditions to heat-source powers. A thickness-averaged heat equation is then converted into a thermal coupling matrix using Green-function superposition and mirror heat sources, explicitly separating self-heating from mutual thermal interference. This reduced model enables efficient evaluation inside a constrained adaptive genetic algorithm. FEM verification shows that the optimized layout reduces the peak temperature from 91.49 °C to 84.86 °C (a reduction of 6.63 °C) and the average substrate temperature by 0.70 °C, without changing the total heat-source power. Infrared thermography shows a peak-temperature decrease from approximately 91.5 °C to 86.8 °C. The optimized infrared peak is close to the FEM prediction of 84.86 °C, with a relative temperature-rise deviation of approximately 4.95%. The results demonstrate that reducing off-diagonal thermal coupling between phases is an effective and physically interpretable design mechanism for suppressing hotspots in high-power-density multiphase converters. The framework does not include EMI, parasitic inductance, or current-sharing constraints in the fitness function, and a full co-optimization would require a multi-objective formulation with an electrical surrogate.
Author Contributions
Conceptualization, Y.C. and X.H.; methodology, Y.C.; software, Y.C.; validation, Y.C. and X.H.; formal analysis, Y.C.; investigation, Y.C.; resources, X.H.; data curation, Y.C.; writing—original draft preparation, Y.C.; writing—review and editing, X.H. and J.Z.; visualization, Y.C.; supervision, X.H. and J.Z.; project administration, X.H.; funding acquisition, X.H. All authors have read and agreed to the published version of the manuscript.
Funding
This research received no external funding.
Data Availability Statement
The data are contained within this article.
Conflicts of Interest
The authors declare no conflicts of interest.
References
- Eckhardt, G.; Lenz, J.M. Four-phase Buck Converter Design and Thermal Modeling Using FEA Simulation. In Proceedings of the Seminar on Power Electronics and Control (SEPOC), Santa Maria, Brazil, 12–15 November 2022; pp. 1–6. [Google Scholar]
- Gupta, C.; Das, M. Multiphase Interleaved DC-DC Converter for Fast Charging Application of Electric Vehicles. In Proceedings of the IEEE International Conference on Compatibility, Power Electronics, and Power Engineering (CPE-POWERENG), Birmingham, UK, 29 June–1 July 2022; pp. 1–6. [Google Scholar]
- Sithananthan Bakar, T.; Saiman, S.; Gani, A.F.H.A. Power Losses Analysis of Multiphase Interleaved DC-DC Boost Converter using OrCAD PSpice Software. In Proceedings of the IEEE 4th International Conference in Power Engineering Applications (ICPEA), Pulau Pinang, Malaysia, 4–5 March 2024; pp. 112–116. [Google Scholar]
- Durán Aranda, E.; Pérez Litrán, S.; Ferrera Prieto, M.B. Combination of Interleaved Single-Input Multiple-Output DC-DC Converters. CSEE J. Power Energy Syst. 2022, 8, 132–142. [Google Scholar] [CrossRef] [Scilit]
- Golla, T.; Kapat, S.; Chittaragi, N.; Setty, R.A.; Sridharan, S. Controller Design and Phase Current Balancing for Fast Dynamic Performance in Voltage Mode Controlled Multiphase Buck Converters. In Proceedings of the IEEE Applied Power Electronics Conference and Exposition (APEC), Orlando, FL, USA, 19–23 March 2023; pp. 2163–2169. [Google Scholar]
- Liu, S.; Mishima, T.; Lai, C.-M. High Efficiency Floating Four-Phase Interleaved Charge-Pump Bidirectional DC-DC Converter with Wide Buck/Boost Voltage Ratio. In Proceedings of the IEEE 10th International Power Electronics and Motion Control Conference (IPEMC-ECCEA Asia), Chengdu, China, 17–20 May 2024; pp. 608–615. [Google Scholar]
- Wani, R.; Patil, S.L.; Shinde, P. Modeling and Simulation of Average Current-Mode Controlled Bidirectional Multiphase DC-DC Converters used in Hybrid Vehicles. In Proceedings of the International Conference for Convergence in Technology (I2CT), Maharashtra, India, 2–4 April 2021; pp. 1–7. [Google Scholar]
- Asghari, A. A Soft Switching Four-Phase Converter with Ultra-High Step-Down Conversion Ratio and Automatic Uniform Current Sharing. IET Power Electron. 2021, 14, 1489–1503. [Google Scholar] [CrossRef] [Scilit]
- Park, J.-S.; Lee, T.-W.; Lee, J.-W.; Park, B.-G.; Kim, J.-W. Optimization of Multi-Phase Motor Drive System Design through Thermal Analysis and Experimental Validation of Heat Dissipation. Electronics 2023, 12, 4177. [Google Scholar] [CrossRef] [Scilit]
- Cao, K.; Ng, W.T.; Trescases, O. Thermal Management for Multi-Phase Current Mode Buck Converters. In Proceedings of the 2011 Twenty-Sixth Annual IEEE Applied Power Electronics Conference and Exposition (APEC), Fort Worth, TX, USA, 6–11 March 2011; pp. 1124–1129. [Google Scholar] [CrossRef] [Scilit]
- Rahman, S.M.I.; Moghassemi, A.; Arsalan, A.; Timilsina, L.; Chamarthi, P.K.; Papari, B.; Ozkan, G.; Edrington, C.S. Emerging Trends and Challenges in Thermal Management of Power Electronic Converters: A State of the Art Review. IEEE Access 2024, 12, 50633–50672. [Google Scholar] [CrossRef] [Scilit]
- Singh, P.; Thangaraju, B. Impact of Thermal Hotspots Formation in High Performance Computing. In Proceedings of the IEEE International Conference on Electronics, Computing and Communication Technologies (CONECCT), Bangalore, India, 8–10 July 2022; pp. 482–487. [Google Scholar]
- Peterson, G.P.; Ortega, A. Thermal control of electronic equipment and devices. In Advances in Heat Transfer; Elsevier: Amsterdam, The Netherlands, 1990; Volume 20, pp. 181–314. [Google Scholar]
- Ning, P.; Li, H.; Huang, Y.; Kang, Y. Review of Power Module Automatic Layout Optimization Methods in Electric Vehicle Applications. Chin. J. Electr. Eng. 2020, 6, 8–24. [Google Scholar] [CrossRef] [Scilit]
- Wu, T.; Ozpineci, B. Impact of Heat Dissipation Profiles on Power Electronics Packaging Design. In Proceedings of the IEEE Transportation Electrification Conference and Expo (ITEC), Long Beach, CA, USA, 13–15 June 2018; pp. 482–487. [Google Scholar]
- Oukaira, A.; Said, D.; Zbitou, J.; Lakhssassi, A. Transient Thermal Analysis of System-in-Package Technology by the Finite Element Method (FEM). In Proceedings of the 2022 IEEE International Conference on Microelectronics (ICM), Casablanca, Morocco, 4–7 December 2022; pp. 30–33. [Google Scholar] [CrossRef] [Scilit]
- Lee, S.-Y.; Pfaelzer, A.G.; Van Wyk, J.D. Thermal analysis for a coupled inductor for 4-channel interleaved automotive bi-directional DC/DC converter based on finite-element modeling. In Proceedings of the IEEE 35th Annual Power Electronics Specialist Conference (PESC 2004), Aachen, Germany, 20–25 June 2004; pp. 1457–1463. [Google Scholar]
- Lin, H.; Wu, L.; Guo, X.; Chen, G. A Comprehensive Model of Forced Air Cooling and Optimal Design Method of High Power Density SiC-Static Var Generator. Trans. China Electrotech. Soc. 2021, 36, 3446–3456. [Google Scholar]
- Jeevan, K.; Seetharamu, K.N.; Ishak, I.A.; Quadir, G.A. Thermal management of multichip-module (MCM) using genetic algorithms. In Proceedings of the TENCON 2003, Conference on Convergent Technologies for Asia-Pacific Region, Bangalore, India, 15–17 October 2003; pp. 474–478. [Google Scholar]
- Katoch, S.; Chauhan, S.S.; Kumar, V. A Review on Genetic Algorithm: Past, Present, and Future. Multimed. Tools Appl. 2021, 80, 8091–8126. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Yang, Y.; Gong, M.; Ma, J. Research on Multi-Heat Source Arrangement Optimization Based on Equivalent Heat Source Method and Reconstructed Variational Autoencoder. Sci. Rep. 2024, 14, 21208. [Google Scholar] [CrossRef] [Scilit] [PubMed]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.