Evolution of Whole-Cell Biosensor Detection Technology for PAHs and Their Halogenated Derivatives Driven by Performance Requirements

,
,
,
,
and
1
Key Laboratory of Digital-Intelligence and Dynamic Perception for Food Quality of China Light Industry, Beijing Technology and Business University, Beijing 100048, China
2
Beijing Laboratory for System Engineering of Carbon Neutrality, Beijing Municipal Education Commission, Beijing 100048, China
3
BTBU-CAU Joint Laboratory of Synthetic Biology for Food, Nutrition and Health, Beijing Technology and Business University, Beijing 100048, China
*
Authors to whom correspondence should be addressed.

Abstract

Polycyclic aromatic hydrocarbons (PAHs) and their halogenated derivatives are important targets in environmental monitoring and pollution control because of their persistence, bioaccumulation, and potential carcinogenicity. Reliable strategies for detecting these pollutants remain essential for environmental risk assessment. In recent years, microbial whole-cell biosensors have attracted increasing attention as analytical tools for pollutant detection and toxicity evaluation. These biosensors employ living cells to recognize target compounds and generate measurable signals through endogenous metabolic pathways and transcriptional regulatory networks. As a result, they can reflect biologically relevant responses and operate in complex environmental matrices, making them suitable for in situ monitoring. This review summarises recent advances in whole-cell biosensors for detecting PAHs and their halogenated derivatives. We discuss the design strategies for constructing these whole-cell biosensors and outline their technological development. Recent efforts to improve biosensor performance are also highlighted. Current research trends indicate a shift from optimizing individual genetic components to improving overall system robustness, standardized evaluation, and practical field deployment. These developments provide important insights for designing reliable and engineerable whole-cell biosensing platforms for monitoring PAHs and related pollutants.

1. Introduction

Polycyclic aromatic hydrocarbons (PAHs) are a class of organic compounds that contain two or more fused benzene rings. These compounds usually appear as colorless, white, or pale yellow solids. Researchers classify PAHs as persistent toxic pollutants because they are widely distributed in the environment and can also form during food processing [1,2]. Plants and microorganisms can produce PAHs through natural biosynthesis, and natural events such as wildfires in forests and grasslands, as well as volcanic eruptions, also release PAHs into the environment [3]. However, recent reviews have shown that atmospheric PAHs are predominantly derived from anthropogenic sources, particularly from the incomplete combustion of fossil fuels and biomass [4,5]. These activities include incomplete combustion of fossil fuels, improper disposal of industrial chemicals, oil and petrol spills, electricity and heating, tobacco smoke, and emissions from barbecuing [6]. Researchers frequently detect PAHs in a wide range of food products [7]. Studies suggest that PAHs enter the food chain through several pathways, including the uptake of PAHs adsorbed to soil particles by plants and animals and the accumulation of PAHs in aquatic environments. Low-molecular-weight PAHs can also adsorb to food surfaces. In addition, food processing and cooking can further increase PAH contamination, as several studies have reported. Halogenated derivatives of PAHs, including polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs), are also widely distributed organic pollutants in the worldwide environment. These compounds have attracted increasing attention in environmental science because they exhibit strong environmental persistence, bioaccumulation, and toxic effects on organisms and humans.
Excessive exposure to PAHs increases the risk of several cancers, including pancreatic, gastric, and breast cancers [8]. The United States Environmental Protection Agency (USEPA) has identified 16 PAHs as “priority pollutants” because they can adversely affect aquatic and terrestrial ecosystems. Among these compounds, studies indicate that seven PAHs are either confirmed or suspected carcinogens. This classification highlights the environmental and public health significance of PAHs and emphasizes the need for effective monitoring and management strategies to mitigate their impacts on ecosystems and human health [9]. Consequently, accurate detection and quantification of PAHs in environmental matrices are essential. Monitoring these compounds in food, water, and soil is particularly important because these media are major routes of human exposure. Reliable analytical methods are therefore required to support regulatory control and to reduce the potential health risks associated with exposure to PAHs and their halogenated derivatives.
Conventional analytical techniques for PAHs and their halogenated derivatives rely on multi-step sample preparation and chromatographic–mass spectrometric platforms, which are often labor-intensive, require expensive instrumentation, and demand highly trained operators, limiting their applicability for rapid, on-site monitoring [10,11]. Although GC-MS/MS-based methods can achieve low detection limits for PAHs and PCBs, typically in the range of 0.1–10 µg·L−1 for aqueous samples [12,13] and down to 0.02–1.5 µg·kg−1 in plant-related matrices [14], and offer a wide linear dynamic range, they still rely on complex laboratory-based analytical workflows that limit their applicability for rapid, on-site monitoring [15]. As contamination of environmental and food matrices by PAHs and PCBs continues to rise, the demand for rapid, on-site, trace-level, and non-destructive detection has grown substantially. In response to this demand, advances in functional material design [16,17], molecular recognition strategies [18], and nanostructured or porous functional materials [19,20] have been developed to improve sensitivity, selectivity, and resistance to interference. Despite these technological advances, both qualitative and quantitative analyses still rely on complex, time-consuming sample-preparation procedures that require substantial amounts of reagents.
Therefore, it is now necessary to develop such green, efficient, and convenient rapid detection technologies to enable in situ qualitative and quantitative detection of PAHs and their halogenated derivatives. Whole-cell biosensors, which use intact living cells as biological recognition elements, have emerged as a promising alternative. In whole-cell biosensors, chassis cells are the host microorganisms that carry and express engineered genetic circuits, whereas sensing elements are the functional genetic components responsible for target recognition and signal generation, such as promoters, transcription factors, or riboswitches. Compared with other rapid detection approaches, whole-cell biosensors offer several advantages for monitoring PAHs and their halogenated derivatives, including broader detection coverage, high sensitivity and specificity, simplified pre-treatment, reduced analysis time, lower operational costs, portability, and environmental compatibility [21]. By directly responding to the biological effects of contaminants in living systems, whole-cell biosensors enable the assessment of the bioavailable fraction of pollutants and their associated toxicity within complex environmental matrices [22]. As shown in Figure 1, whole-cell biosensors are used to detect PAHs and their halogenated derivatives in diverse environmental contexts.
Figure 1. Applications of whole-cell biosensors for detecting PAHs and their halogenated derivatives. The graphical elements were adapted and combined from free images obtained from Vecteezy (https://www.vecteezy.com, accessed on 2 June 2026).
Although substantial progress has been made in recent studies, a comprehensive review systematically addressing whole-cell biosensors for PAHs and their halogenated derivatives remains lacking. Existing literature rarely offers an integrated perspective on the key functional components and fundamental design strategies underpinning these whole-cell biosensors, and discussions of optimization pathways to address practical application challenges remain limited. This review summarises recent advances in the development of whole-cell biosensors for detecting PAHs and their halogenated derivatives and further discusses the underlying design principles and technological progress. In addition, the major challenges currently confronting this field are examined, and potential future research directions are outlined, with particular emphasis on the importance of interdisciplinary collaboration to accelerate the practical application of whole-cell biosensors in environmental and food contaminant monitoring.

2. Overview of the Mechanism of Action of Whole-Cell Biosensors

Whole-cell biosensors are dynamic detection systems that translate biological responses into measurable output signals. Based on the location of target recognition and the pathways of signal transduction, intracellular and extracellular sensing mechanisms have gradually evolved towards coordinated integration. This integrated sensing framework offers new possibilities for detecting membrane-impermeable targets and enables real-time dynamic monitoring. Understanding this coordinated process is therefore important for the rational design and performance optimization of whole-cell biosensors and for improving their reliability in complex sample analysis.

2.1. Intracellular Sensing Mechanism

Previous studies show that intracellular sensing in whole-cell biosensors mainly relies on genetically engineered regulatory circuits to achieve target recognition, signal amplification, and quantitative signal output. These systems are typically constructed by genetically modifying living microorganisms, such as bacteria or yeast, to perform specific detection tasks [23]. A typical whole-cell sensing system comprises two key components: a sensing module and a reporter module [24,25]. In the absence of the target molecule, the sensing protein binds to the promoter region, thereby repressing downstream gene expression. When the target compound is present, it interacts with the sensing protein, inducing a conformational change that leads to dissociation from the promoter and relieves transcriptional repression, thereby activating reporter gene expression (Figure 2A).
Figure 2. Schematic representation of intracellular and extracellular sensing mechanisms. (A) Intracellular sensing mechanisms in whole-cell biosensors. (B) Mechanisms of action of whole-cell biosensors outside the cell.
The intensity of the reporter signal typically correlates with the concentration of the target compound, enabling quantitative detection. In addition to optical outputs, some engineered strains can produce electrochemically active metabolites. These metabolites generate measurable electrical currents when they interact with microelectrodes, thereby linking gene regulation to electrical signal readout and enabling rapid analysis and high-throughput detection [26]. By integrating molecular recognition, signal amplification, and multimodal signal readout within living cells, this sensing strategy provides an important basis for real-time monitoring and online analysis in complex samples.

2.2. Extracellular Sensing Mechanism

Building on intracellular sensing, whole-cell biosensors can further expand their detection capability through extracellular sensing. In this strategy, membrane receptors or engineered binding elements capture target molecules outside the cell and transmit signals across the membrane, triggering intracellular responses and thereby broadening the range of detectable targets. Extracellular sensing mainly relies on specific molecular recognition (Figure 2B). These systems use membrane-bound receptors, secreted proteins, or artificially designed binding elements to recognize target molecules and initiate transmembrane signal transduction, such as activating second messengers or two-component regulatory systems. These signaling processes subsequently activate intracellular gene circuits, producing measurable output [27,28].
The interaction between a receptor and a target molecule typically induces a conformational change in the receptor. This structural change converts external physicochemical stimuli into intracellular biochemical signals and regulates downstream enzymatic or transcriptional activity. Signal conversion may occur directly through one-component regulatory systems or indirectly through phosphotransduction in two-component systems. In both cases, extracellular molecular recognition is tightly coupled to intracellular gene circuit regulation. For example, the CadC receptor in bacterial transmembrane signaling systems contains acidic amino acid residues that become protonated at low pH. The receptor functions together with the LysP transporter protein to sense environmental changes and regulate cellular responses [29].
Engineered cells can also secrete aptamers or antibody fragments to capture target molecules in the extracellular environment. The resulting complexes can then be recognised by membrane receptors, which further enhances detection sensitivity. Many hydrophobic pollutants cannot readily cross cell membranes and therefore cannot be efficiently recognised by intracellular sensing systems. This limitation may lead to measured values that are lower than the actual concentrations. To address this problem, researchers combined the luc luminescent gene with the extracellular sensor gene chr1_2466, enabling the luminescent signal to be generated outside the cell [30]. This strategy enables convenient, automated, real-time monitoring and shows strong potential for on-site qualitative and quantitative detection. Although this approach expands the detectable range and improves sensitivity, further studies are still needed to assess detection stability and practical performance in real-world environmental conditions.

3. Preparation for the Construction of Whole-Cell Biosensors for PAHs and Their Halogenated Derivatives

Whole-cell biosensors generally consist of three core components: chassis cells, recognition modules, and signal reporter modules. The coordinated function of these elements enables efficient target sensing and signal transduction. Through this integrated design, whole-cell biosensors can achieve sensitive detection of PAHs and their halogenated derivatives.

3.1. Common Chassis Cells for Whole-Cell Biosensors of PAHs and Their Halogenated Derivatives

Rational selection and engineering of chassis cells remain essential to improving the environmental robustness and practical applicability of whole-cell biosensors. Chassis cells should exhibit strong ecological adaptability to ensure the biosensor functions reliably in complex, contaminated environments. Table 1 summarises the chassis cells commonly used in related sensor studies, most of which are derived from natural environmental isolates. Native strains often show advantages in specific environmental conditions, but they can also present certain limitations for practical detection. Chassis cells may provide high sensing performance, yet environmental factors can still affect their detection capability. For example, chassis cells used for marine monitoring must withstand high salinity and adapt to temperature fluctuations and other environmental stresses [31].
Species of the genus Pseudomonas can degrade a wide range of organic pollutants and have therefore been used as sensing elements for detecting various environmental contaminants [32]. For example, King proposed Pseudomonas fluorescens HK44 [33], which carries genes involved in naphthalene degradation, as a chassis cell for constructing a whole-cell biosensor targeting naphthalene. However, Pseudomonas species are relatively difficult to manipulate genetically, often have longer growth cycles, and some strains show limited adaptability to changing environmental conditions. These factors limit their broader use in rapid, low-cost detection platforms. To address these limitations, researchers have explored alternative chassis organisms. Escherichia coli has gradually become a widely used host for constructing whole-cell biosensors because it is genetically easy to engineer, grows rapidly, and incurs relatively low cultivation costs. For instance, genetically engineered Escherichia coli-based whole-cell biosensors have been used to quantify PAH biodegradation and toxicity in various environments, including contaminated soils [34].
Functional microorganisms isolated from specific polluted environments are increasingly regarded as promising chassis cells for constructing whole-cell biosensors because they often exhibit long-term environmental adaptability and specialized metabolic capabilities [35]. For example, Burkholderia sartisoli is widely distributed in soil and seawater and is considered harmless to humans. This species can tolerate fluctuations in temperature, pH, and salinity. Using Burkholderia sartisoli RP007 as the chassis cell, researchers developed a biosensor for screening marine oil spills [36], which enabled specific detection of several water-soluble compounds. Similarly, the hydrophobic strain Sphingobium xenophagum C1, isolated from river sediments contaminated with electronic waste, has evolved a highly hydrophobic cell surface and multiple metal-resistance mechanisms following long-term exposure to high concentrations of PBDEs and heavy metals [37]. The hydrophobic surface of this strain enhances the bioavailability of hydrophobic pollutants and helps overcome the low detection sensitivity often observed in conventional hydrophilic strains. At the same time, its inherent tolerance to pollutants supports stable biosensor signals in complex environments and reduces the need for external additives, such as surfactants. Biosensors constructed from such environmentally adapted microorganisms can leverage the natural ecological robustness of the host cells, thereby enabling sensitive detection of specific pollutants in complex environmental matrices.
Table 1. Chassis cells for whole-cell biosensors for PAHs and their halogenated derivatives.

3.2. Sensing Elements for Whole-Cell Biosensors for PAHs and Their Halogenated Derivatives

The construction of whole-cell biosensors for pollutant detection relies on sensing elements that specifically recognize target molecules. In studies targeting PAHs, polychlorinated biphenyls, and polybrominated diphenyl ethers, researchers have gradually expanded the types of sensing elements used in biosensor design. These elements now range from intracellular transcription factors to membrane-associated sensor proteins, enabling broader molecular recognition and improved sensing performance.
Detection of PAHs in whole-cell biosensors often relies on the specific recognition ability of transcription factors. Among the most widely studied regulators are PhnR and PhnS, which are commonly used for phenanthrene detection (Figure 3A,B), and NahR, which is frequently used for naphthalene sensing (Figure 3C). PhnS and PhnR were originally identified in Burkholderia sartisoli RP007 [43]. PhnS belongs to the LysR-type transcriptional regulator family and activates the phn gene cluster in response to phenanthrene. In contrast, PhnR is a σ54-dependent positive regulator in the NtrC family. These two regulators coordinately control the degradation pathways of phenanthrene and naphthalene. The transcription factor NahR, derived from Pseudomonas putida G7, also belongs to the LysR family [44,45], but its regulatory mechanism has been more clearly characterized. In the presence of salicylic acid, the NahR protein binds to a conserved DNA sequence upstream of the nah operon promoter and activates transcription of the upper naphthalene degradation pathway. Salicylic acid then acts as an inducer, further stimulating the lower degradation pathway and ultimately enabling the reporter strain to produce a quantifiable luminescent signal.
Detection of polychlorinated biphenyls (PCBs) and their derivatives often requires more sophisticated sensing element design. The biodegradation of PCBs mainly proceeds through the biphenyl operon-mediated catabolic pathway, in which the enzyme biphenyl dioxygenase BphA (Figure 3D) catalyzes the initial oxidation step and largely determines the substrate recognition range [46]. Researchers isolated the orf0-bphA1 gene cluster from Ralstonia eutropha ENV307 [47,48]. However, the upstream orf0 gene shows low homology to known transcriptional regulators, suggesting a potentially distinct regulatory mechanism [42]. For hydroxylated polychlorinated biphenyls, the transcription factor HbpR (Figure 3E), derived from Pseudomonas azelaica HBP1, has been identified as a LysR-family regulator capable of specifically recognising hydroxylated compounds with a biphenyl backbone. In the absence of an inducer, HbpR binds to the promoter region and represses transcription. Upon binding to the inducer molecule, HbpR undergoes a conformational change that relieves repression and activates downstream gene expression. Based on this regulatory mechanism, HbpR has been widely used to construct whole-cell biosensors for detecting hydroxylated biphenyl compounds.
Although transcription factor-based sensing systems have achieved considerable success in whole-cell biosensor detection, these elements operate intracellularly and therefore rely on efficient transmembrane transport of target molecules. For highly hydrophobic persistent organic pollutants, this transport process can become the rate-limiting step, leading to delayed responses or reduced detection sensitivity. To address this limitation, recent studies have begun exploring sensing elements on the cell surface. For example, Chen and colleagues [30] compared the transcriptomic responses of the hydrophobic strain Sphingobium xenophagum C1 and its variants under exposure to decabromodiphenyl ether and identified a membrane-associated protein, Chr1_2466 (Figure 3F). This protein contains a Cache domain and is localized on the outer membrane, enabling extracellular recognition of polybrominated diphenyl ethers.
Unlike transcription factors that rely on intracellular degradation pathways, Chr1_2466 directly recognizes decabromodiphenyl ether and its lower-brominated homologs, yet shows no response to 29 potential interferents, including polychlorinated biphenyls and phenolic compounds [49]. The binding affinity of this protein increases with the number of bromine atoms in the target molecules. Interestingly, its localization at the membrane surface enables real-time monitoring of target molecules via fluorescence without the need for cell lysis. This feature significantly improves detection convenience and provides a promising strategy for the in situ monitoring of hydrophobic organic pollutants.
Figure 3. Sensing elements for whole-cell biosensors for PAHs and their halogenated derivatives. Protein structure obtained from the AlphaFold Protein Structure Database, refs. [50,51]. (A) PhnS. (B) PhnR. (C) NahR. (D) BphA. (E) HbpR. (F) Histidine kinase.

3.3. Commonly Used Reporter Elements for Whole-Cell Biosensors of PAHs and Their Halogenated Derivatives

During the construction of whole-cell biosensors, the promoter responsive to the target analyte is typically fused to an appropriate reporter gene. The expressed reporter protein can generate detectable signals in various forms, including colorimetric, fluorescent, bioluminescent, chemiluminescent, or electrochemical outputs [49]. Different reporting platforms exhibit significant differences in signal generation mechanisms, metabolic dependence, and field applicability, and their selection directly influences the biosensor’s detection performance and practical value [52]. Table 2 summarises commonly used reporter elements for constructing whole-cell biosensors targeting PAHs and their halogenated derivatives. Owing to their favourable catalytic properties, efficient light emission, and broad applications in bioluminescent systems, fluorescent proteins and luciferases have become major research foci in biosensing. Green fluorescent protein, originally isolated by Osamu Shimomura from Aequorea victoria, derives its fluorescence from a chromophore formed autocatalytically by the Ser65-Tyr66-Gly67 tripeptide within the protein [53,54]. The principal advantages of the GFP system lie in its independence from exogenous substrates, low cytotoxicity, and suitability for real-time imaging in living cells, while maintaining structural stability over a relatively broad pH range. However, chromophore maturation requires time, which may delay signal output and reduce temporal resolution. In addition, background fluorescence and light scattering, which are commonly present in environmental samples, can markedly decrease the signal-to-noise ratio, thereby limiting sensitivity for trace pollutant detection [55]. Consequently, GFP is more suitable for mechanistic investigations or cellular-level response analyses, whereas it is generally less advantageous for monitoring low-concentration environmental contaminants.
In contrast, bioluminescent systems based on the lux genes exhibit superior performance in environmental detection due to their low background noise and high signal sensitivity. The lux gene cluster typically comprises luxICDABE together with the regulatory element luxR [56]. Among them, luxAB encodes the heterodimeric luciferase, while luxCDE participates in the endogenous regeneration of the fatty aldehyde substrate. When the complete luxABCDE cluster is employed, cells can achieve continuous, substrate-self-sufficient luminescence without exogenous substrate addition, enabling in situ and online monitoring strategies [57]. The luminescent reaction depends on molecular oxygen, oxidising fatty aldehydes to the corresponding carboxylic acids and emitting visible light [58], with emission intensity closely correlated with cellular metabolic activity and transcriptional levels. Because the luminescence process is highly dependent on ATP supply and aerobic metabolic conditions, signal attenuation readily occurs under nutrient-limited or hypoxic environments in whole-cell biosensors [59,60], which imposes potential constraints for applications in sediments or highly contaminated microenvironments.
Firefly luciferase is derived from the North American firefly Photinus pyralis [61,62]. Its encoding gene, luc, has been widely applied in bioluminescent reporter systems because of its high catalytic efficiency and strong light emission. In the presence of ATP, Mg2+, and oxygen, this enzyme catalyses the oxidation of luciferin, producing a high quantum yield and intense, instantaneous light output, making it suitable for high-precision quantitative analysis. In the construction of hydrophobic whole-cell biosensors, luciferase catalyses the oxidation of the substrate furimazine, generating a bioluminescent signal proportional to the concentration of PBDEs [30]. However, firefly luciferase shows relatively limited thermal stability, and its sustained performance under complex environmental conditions is somewhat constrained. In addition, the requirement for exogenous furimazine increases detection costs.
Table 2. Reporter elements used in whole-cell biosensors for PAHs and their halogenated derivatives.

4. Preliminary Construction of Whole-Cell Biosensors for PAHs and Their Halogenated Derivatives

Traditional transcription- and regulation-based whole-cell biosensors were the core technological paradigm in early studies monitoring the bioavailability of PAHs and their halogenated derivatives. Their design relies on inducible transcriptional regulators derived from microbial aromatic hydrocarbon degradation pathways. In these systems, pollutant-responsive promoters are transcriptionally fused with reporter genes, enabling biological signals generated upon pollutant recognition to be converted into quantifiable optical outputs.

4.1. Early Biosensor Construction Strategies Based on Genetic Circuits

During the early development of whole-cell biosensors, transcriptionally regulated genetic circuits established the technical foundation of the field. Burlage and colleagues developed a lux-based real-time reporting system and, for the first time, transcriptionally fused the Pnah promoter from the NAH7 plasmid with the luxCDABE gene cluster to construct plasmid pUTK9, enabling real-time and noninvasive monitoring of naphthalene catabolism [65]. In this design, a pollutant-responsive promoter drives the expression of the luxCDABE bioluminescent genes, thereby directly coupling metabolic activity to optical signal output. Consequently, luminescence intensity dynamically reflects the degradation status of substrates such as naphthalene. This metabolism-driven signal transduction architecture represents a transition from endpoint detection to real-time monitoring and provides an operational framework for evaluating exposure to environmental pollutants. However, these early genetic circuit fusions lacked insulation and modular design, which made them susceptible to effects from construct orientation and genomic insertion sites and could compromise system stability. Therefore, effective circuit design should ensure that functional genetic modules remain insulated from host regulatory backgrounds and other introduced genetic elements, thereby preventing signal interference or regulatory crosstalk and maintaining the biosensing circuit’s independence and stability.
King and colleagues subsequently constructed the reporter plasmid pUTK21 and developed the engineered strains 5RL and HK44 as whole-cell biosensors for real-time monitoring of naphthalene exposure and biodegradation [33]. This system responds rapidly, within 15 min of induction by naphthalene or salicylic acid, and the luminescence intensity remains synchronized with naphthalene degradation dynamics. However, practical applications still face several challenges. Limited specificity restricts the broader applicability of this system and highlights the need for highly specific recognition modules in real-world deployment.

4.2. Metabolically Coupled Whole-Cell Biosensors: Strategies Centered on Bioavailability

From the perspective of environmental risk assessment, the bioavailability of pollutants is often more ecologically relevant than their total concentration. Early whole-cell biosensors were therefore frequently designed to couple pollutant uptake and metabolic processes to signal generation, thereby converting metabolic flux into detectable outputs. This strategy enables dynamic evaluation of the bioavailable fraction of target compounds and, in principle, provides a more realistic representation of pollutant accessibility to microbial communities. However, the performance of such systems is strongly influenced by the physiological state of the host cells and by environmental conditions.
Represented by the naphthalene-responsive system constructed by Heitzer and colleagues [66], a whole-cell biosensing platform based on the nahG-luxCDABE fusion protein was developed to quantitatively assess the bioavailability of naphthalene and salicylate in environmental samples. Their results demonstrated that cells in the exponential growth phase exhibited a stronger and more reliable bioluminescence response than carbon-starved cells, while also reducing interference from non-target substrates. The higher basal metabolic activity and increased reporter output per unit biomass indicate an intrinsic biological signal amplification effect within the system. However, the study also showed limited reproducibility, with significant variations in calibration curve slopes across independent experiments. In complex matrices such as soil slurry, signal attenuation occurred due to adsorption of target compounds and optical quenching, resulting in a marked reduction in detection efficiency compared with aqueous samples. These matrix-dependent effects pose challenges for field deployment and long-term operational stability.
Furthermore, the engineered strain Pseudomonas fluorescens HK44 carrying the nahG-luxCDABE reporter gene system was immobilized in a strontium alginate matrix [67]. The immobilized cells stored at 4 °C maintained viability during short-term storage, and the immobilization process enhanced cell retention, thereby enabling stable signal generation under continuous-flow conditions. A dual-channel HPLC pump system was employed to precisely mix the maintenance medium and the sample stream, thereby providing stable and reproducible hydrodynamic conditions. In addition, a flow-through configuration with an integrated optical probe was constructed, enabling real-time bioluminescence monitoring during continuous operation. However, temporal variations in cellular activity and diffusion limitations within the immobilization matrix may lead to signal drift, potentially affecting baseline stability. Therefore, periodic recalibration is required in practical applications. In addition, field deployment may be constrained by system maintenance requirements and the need for strictly controlled flow conditions.
Similarly, Tecon et al. constructed a phenanthrene-responsive fluorescent biosensor based on the PhnR–phnS regulatory system from Burkholderia sp. RP007 by fusing the phnS promoter to enhanced GFP, enabling amplified fluorescence output through transcriptional activation during phenanthrene metabolism [39]. The generated signal was directly correlated with pollutant bioavailability, providing practical relevance for ecological risk assessment, and metabolic activity could be maintained through supplementation with auxiliary carbon sources to improve signal stability. In essence, this system depends on multiple biological processes, including pollutant uptake, metabolic transformation, and subsequent transcription and translation, resulting in an inherently multi-step response with an unavoidable temporal delay. At the same time, reliance on a single fluorescent output limits signal amplification capacity, while output intensity is highly sensitive to variations in host metabolic state and environmental conditions. In real environmental matrices, coexisting aromatic compounds, unknown inhibitors, and matrix-associated toxicity can further distort signal output and reduce cellular viability, thereby limiting quantitative accuracy. These inherent constraints restrict the robustness and field applicability of transcriptional regulation-based biosensors in complex real-world settings.

4.3. Application Expansion of Traditional Genetic Circuits in Pollutant Detection

Within the framework of metabolically coupled genetic circuits, whole-cell biosensors were further developed to respond to low solubility and hydrophobic organic pollutants, thereby enabling indirect characterisation of their bioavailability. Layton and colleagues constructed a whole-cell biosensor centred on Ralstonia eutropha ENV307 carrying pUTK60, in which the regulatory module of the biphenyl degradation pathway, orf0-bphA1, was fused with the lux gene cluster, allowing induction signals from polychlorinated biphenyls to be converted into measurable luminescent outputs [41]. To address the low solubility and limited environmental availability of PCBs, the system incorporated nonionic surfactants to enhance substrate solubilization and mass-transfer efficiency, thereby significantly improving detection sensitivity, with a minimum detection limit of 0.15 mg∙L−1. Experimental results demonstrated that biphenyl, monochlorobiphenyl, and Aroclor 1242 could induce a three to fourfold increase in luminescence, indicating the potential applicability of this system in complex environmental samples. Although this study extended the application boundaries of traditional genetic circuits for detecting hydrophobic persistent pollutants, its strong dependence on mass-transfer efficiency and metabolic balance also highlights substantial potential to improve engineering controllability in whole-cell biosensing strategies. However, the reported detection limits and induction factors are dependent on surfactant-assisted solubilization of hydrophobic substrates, introducing uncertainty in environmental reproducibility.

5. Optimization Strategies for Whole-Cell Biosensor Systems Targeting PAHs and Their Halogenated Derivatives, Driven by Structural Constraints

Early whole-cell biosensors for PAHs and their halogenated derivatives were primarily constructed based on natural aromatic hydrocarbon degradation regulatory networks. Their sensing performance was constrained by several inherent structural bottlenecks, including insufficient molecular recognition specificity, limited mass transfer efficiency, inefficient metabolic coupling, and the metabolic burden imposed on host cells. In recent years, optimization strategies have gradually shifted from modifying individual components to system-level reconstruction, aiming to improve sensing performance across multiple functional layers, including molecular regulation, interfacial mass transfer, metabolic flux distribution, and chassis homeostasis.

5.1. Optimization at the Level of Molecular Recognition and Transcriptional Regulation

The precision of molecular recognition determines the selectivity and sensitivity of whole-cell biosensors. Structural optimization of natural aromatic-responsive transcription factors has become an important strategy for improving recognition efficiency. For example, Shin and colleagues performed site-directed mutagenesis in the inducer-binding region and oligomerization domain of the NahR protein to improve the sensitivity of a microbial biosensor for salicylate detection [68]. Among the generated variants, the N169C and R248Q mutants significantly altered the transcriptional response, achieving up to a 50-fold increase in luminescence under optimized inducer concentrations. This improvement is mainly attributed to changes in inducer-binding affinity and alterations in regulatory conformational dynamics, which enhance transcriptional activation efficiency. However, enhanced signal output does not necessarily correspond to improved analytical performance, as it may be accompanied by increased background activity or reduced specificity, particularly in mutants with broadened ligand recognition profiles. Therefore, although rational mutagenesis can significantly improve sensitivity, maintaining specificity and response stability remain key challenges in biosensor optimization.
In addition to transcription factor engineering, promoter optimisation is also used to enhance the strength of the response. The metabolites of polychlorinated biphenyls (PCBs), such as hydroxylated PCBs (OH-PCBs), have been identified as environmental contaminants. Various studies have shown that some OH-PCBs can potentially contribute to health problems. In addition to transcription factor engineering, promoter optimization has also been employed to enhance response intensity. Turner and colleagues [42] utilized an hbpR-regulated promoter that specifically recognizes hydroxylated biphenyl skeletons, thereby excluding interference from parent PCBs and non-hydroxylated analogs. On this basis, they constructed a genetically engineered whole-cell biosensor integrating the HbpR regulatory protein with the luxAB luciferase reporter genes, thereby improving detection stability and sensitivity. This biosensor overcame the dependence of conventional chromatographic mass spectrometric techniques on extensive sample purification, enabling direct detection of OH-PCBs and multiple OH-PCBs isomers in complex matrices such as human serum without complicated pretreatment. This advancement extended biosensing technology from laboratory-based research to metabolite toxicity monitoring, providing a high-throughput, rapid, and cost-effective on-site screening tool for evaluating the biological activity of persistent organic pollutants and supporting clinical toxicology studies. However, the application of this biosensor is still largely confined to controlled experimental settings or spiked samples, and its performance in truly heterogeneous environmental matrices has yet to be fully validated. In addition, the need for optimized assay conditions and external sample processing may limit its direct applicability for routine field deployment. To further enhance downstream metabolic gene expression and shorten response time, Sun and colleagues proposed replacing the native nahR regulatory system with the constitutive strong promoter Ptet to directly drive high-level expression of the nahAD gene cluster [69]. Although such strong driving strategies may increase basal expression and metabolic burden, optimization at the transcriptional regulation level has demonstrated significant effectiveness in strengthening signal output.

5.2. Optimization of Mass Transfer and Interfacial Engineering

The low aqueous solubility and slow diffusion rate of PAHs such as naphthalene limit their contact efficiency with cells. These physicochemical properties result in insufficient sensitivity of conventional whole-cell biosensors when detecting low concentrations of hydrophobic organic pollutants, making it difficult to reach detection limits required for practical environmental monitoring. Optimization of interfacial mass transfer has therefore become a critical breakthrough strategy. Werlen and colleagues developed a gas phase detection system that exploited the gas–water partitioning characteristics of PAHs to significantly enhance diffusion rates [70], thereby improving sensitivity at low concentrations. The research group immobilized the engineered Pseudomonas putida pPG7-JAMA21 strain onto the surface of a nylon membrane with a pore size of 0.45 μm, thereby reducing mass-transfer resistance in the aqueous boundary layer and preventing signal delays caused by diffusion limitations around suspended cells. Although this approach offers clear theoretical advantages in mass transfer kinetics, its stability and level of standardization in complex environmental samples still require further validation. The gas-phase configuration not only enhances sensitivity but also more realistically simulates microorganisms’ natural exposure to pollutants at the soil–air interface, thereby increasing the environmental relevance of the detection results.
During the detection of target chemicals by whole-cell biosensors, the cell membrane can act as a barrier [71]. Under such conditions, sensitivity toward the target compound largely depends on its uptake efficiency. Therefore, increased membrane permeability or enhanced cellular uptake of the analyte generally leads to improved detection sensitivity [72]. The introduction of transmembrane sensing proteins has provided a new strategy for recognizing hydrophobic pollutants. Engineering the cell–surface interface helps overcome mass-transfer limitations for highly hydrophobic pollutants in real environmental samples. For example, a novel Cache domain containing a transmembrane receptor identified in tolerant strains has been shown to specifically recognize the brominated sites of PBDEs [30], providing a biological basis for improving pollutant recognition at the cell–environment interface. By coupling this receptor with a nano-fluorescent labeling system and exploiting the intrinsic hydrophobicity of the host cell surface as a natural enrichment interface, PBDE molecules can be more effectively accumulated near the sensing interface, thereby increasing their local contact probability with the recognition element. However, this interface-driven enrichment remains closely dependent on both cell-surface properties and environmental matrix composition; therefore, its performance may vary across sample types and is not always readily reproducible under complex conditions.

5.3. Optimization of Metabolic Efficiency and Signal Amplification Mechanisms

Conventional PAH biosensors typically rely on the metabolic conversion of pollutants to generate signal molecules that subsequently trigger reporter expression, meaning that metabolic flux directly determines the efficiency of signal output. To enhance responsiveness to low-concentration pollutants, researchers have optimized signal generation rates through pathway substitution and metabolic module reconstruction. For instance, overexpression of key enzymes in the naphthalene degradation pathway has been used to improve salicylic acid production efficiency, as the gene cluster from Pseudomonas putida encodes enzymes that specifically catalyze naphthalene metabolism via the salicylate pathway without significantly affecting other organic substrates [69]. In addition, modular sensing architectures based on standardized signaling systems such as salAR–lux have enabled the flexible construction of biosensors for different PAHs by replacing upstream metabolic modules, thereby improving system adaptability and multiplexing capability.
However, these metabolic optimization strategies often rely on increased heterologous gene expression, which can impose a metabolic burden on host cells and disrupt cellular resource allocation. Such imbalances may lead to reduced growth fitness, variability in signals, or long-term instability, particularly under nutrient-limited or environmentally variable conditions. Therefore, while metabolic optimization can significantly enhance signal amplification capacity, its effectiveness is ultimately constrained by the need to maintain host metabolic homeostasis. Future design strategies should therefore focus on balancing pathway efficiency with cellular resource management to ensure stable, robust, and reproducible biosensing performance in complex environmental applications.

5.4. Optimization of Chassis Cell Homeostasis

The chassis cell functions not only as the execution unit for signal generation but also as a major constraint in whole-cell biosensor systems. High-level expression and extensive metabolic reconstruction inevitably increase resource consumption and physiological stress, resulting in signal drift or growth limitation. Therefore, the objective of chassis engineering is not simply to maximize expression levels, but to establish a homeostatic balance between low metabolic burden and high signal output. For example, Acinetobacter ADPWH_lux with low background luminescence has been employed as a host strain [73]. This strain exhibits high compatibility with heterologous expression of the nahAD genes [69], and its plasmid demonstrates strong stability, maintaining a survival rate above 90 percent for 72 h even in the absence of antibiotic selection, thereby enabling long-term stable operation of the biosensor. In addition, optimizing gene integration strategies and constructing negative control systems can further reduce endogenous interference. At present, most designs still rely on static expression modes and lack dynamic feedback regulation mechanisms. Future chassis optimization should incorporate resource-allocation sensing and adaptive regulatory networks, enabling the sensing system to achieve environment-driven homeostatic self-regulation and improved long-term stability.

7. Summary and Perspectives

Overall, the development of whole-cell biosensors targeting PAHs and their halogenated derivatives has progressed from transcription-regulation-based constructs to modular optimization and, more recently, to exploratory translational applications. Advances in chassis cell selection, sensing element engineering, reporter system refinement, and the reinforcement of metabolic coupling strategies have collectively improved sensitivity, response specificity, and signal amplification efficiency, thereby gradually establishing a more systematic design framework. However, from a broader developmental perspective, a substantial gap remains between laboratory-level optimization and stable operation in complex environmental settings or large-scale deployment. Whole-cell biosensors inherently rely on living systems. While metabolic responsiveness and specificity confer high sensitivity, they also introduce signal variability and limited reproducibility. Moreover, the low solubility and strong hydrophobicity of PAHs and their halogenated derivatives make detection outcomes highly dependent on bioavailability rather than total environmental burden, potentially leading to structural bias in risk interpretation. A further critical limitation is the absence of unified performance evaluation standards and standardized testing frameworks. The lack of comparability across studies restricts effective pathway selection, benchmarking, and iterative optimization. Despite these challenges, the future development of whole-cell biosensors remains highly promising and dynamic. Continued integration of synthetic biology, systems engineering, and standardized validation strategies will be essential to unlocking their full potential for reliable, field-deployable environmental monitoring. Beyond technical performance, biosafety constraints, regulatory uncertainty, and societal acceptance remain key determinants for the successful environmental deployment of whole-cell biosensors.
Future development should not remain confined to incremental optimization at the component level but instead shift toward system-level engineering reconstruction and standardized integration. Enhancing overall robustness and predictability, establishing quantifiable and comparable performance benchmarks, and achieving deep coupling between design strategies and application scenarios are essential to advancing the field from proof-of-concept demonstrations to practical implementation. Whether the structural tension between biological complexity and engineering controllability can be effectively reconciled will ultimately determine the real value of whole-cell biosensors in field monitoring. With the continued convergence of synthetic biology, microsystems engineering, and intelligent computational platforms, whole-cell biosensors may evolve from static detection tools into distributed environmental sensing networks endowed with self-regulation, adaptive renewal, and cooperative perception capabilities. Such systems could enable high-throughput, real-time, and fine-grained risk identification in complex pollution contexts. This paradigm shift, from constructing individual biosensors to deploying intelligent sensing infrastructures, may ultimately define the strategic role of whole-cell biosensing technologies in future environmental monitoring and precision governance.

Author Contributions

Writing—original draft, J.Z.; writing—review and editing, W.M. and S.X.; Methodology, L.H.; Funding acquisition, M.G.; conceptualization, M.G.; Supervision, H.L. All authors have read and agreed to the published version of the manuscript.

Funding

This work was supported by the National Natural Science Foundation of China (Grant No. 32572691).

Institutional Review Board Statement

Not applicable.

Data Availability Statement

No new data were created or analyzed in this study.

Acknowledgments

During the preparation of this manuscript, the authors used ChatGPT (GPT-5.5, OpenAI) for partial translation and language polishing. The authors have reviewed and edited the generated content and take full responsibility for the content of this publication. We sincerely acknowledge Vecteezy for providing free graphical materials used in the preparation of Figure 1.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Monteiro, F.C.; Carreira, R.d.S.; Gramlich, K.C.; de Pinho, J.V.; Massone, C.G.; Vianna, M.; Hauser-Davis, R.A. A Systematic Review on Polycyclic Aromatic Hydrocarbon Contamination in Elasmobranchs and Associated Human Health Risks. Mar. Pollut. Bull. 2023, 195, 115535. [Google Scholar] [CrossRef] [Scilit]
  2. Barathi, S.; Gitanjali, J.; Rathinasamy, G.; Sabapathi, N.; Aruljothi, K.N.; Lee, J.; Kandasamy, S. Recent Trends in Polycyclic Aromatic Hydrocarbons Pollution Distribution and Counteracting Bio-Remediation Strategies. Chemosphere 2023, 337, 139396. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  3. Faboya, O.L.; Sojinu, S.O.; Oguntuase, B.J.; Sonibare, O.O. Impact of Forest Fires on Polycyclic Aromatic Hydrocarbon Concentrations and Stable Carbon Isotope Compositions in Burnt Soils from Tropical Forest, Nigeria. Sci. Afr. 2020, 8, e00331. [Google Scholar] [CrossRef] [Scilit]
  4. Li, R.; Liu, X.; Shen, Y.; Shao, Y.; Gao, Y.; Yao, Z.; Liu, X.; Shi, G. Measurement Report: Polycyclic Aromatic Hydrocarbons (PAHs) and Their Alkylated (RPAHs), Nitrated (NPAHs), and Oxygenated (OPAHs) Derivatives in the Global Marine Atmosphere—Occurrence, Spatial Variations, and Source Apportionment. Atmos. Chem. Phys. 2025, 25, 9263–9274. [Google Scholar] [CrossRef] [Scilit]
  5. Wu, Y.; Zhang, H.; Zhang, H.; Zeng, T.; Qiao, N.; Shi, Y.; Zhang, N.; Luo, W.; Lu, S. Risks and Sources of Atmospheric Particulate-Bound Polycyclic Aromatic Hydrocarbons (AP-PAHs) in Seven Regions of China: A Review. Urban Clim. 2024, 57, 102108. [Google Scholar] [CrossRef] [Scilit]
  6. Bansal, V.; Kim, K.-H. Review of PAH Contamination in Food Products and Their Health Hazards. Environ. Int. 2015, 84, 26–38. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  7. Liu, R.; Pei, Q.; Sun, T.; Xu, F.; Shao, X.; Liu, J.; Yan, Z.; Wang, D.; Tian, Y.; Jing, D. Recent Advances in Shellfish Toxin Biosensing Technologies: Micro/Nano Molecule- and Cell-Based Biosensors. Trends Food Sci. Technol. 2024, 152, 104692. [Google Scholar] [CrossRef] [Scilit]
  8. Hamidi, E.N.; Hajeb, P.; Selamat, J.; Razis, A.F.A. Polycyclic Aromatic Hydrocarbons (PAHs) and Their Bioaccessibility in Meat: A Tool for Assessing Human Cancer Risk. Asian Pac. J. Cancer Prev. 2016, 17, 15–23. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  9. Venkatraman, G.; Giribabu, N.; Mohan, P.S.; Muttiah, B.; Govindarajan, V.K.; Alagiri, M.; Abdul Rahman, P.S.; Karsani, S.A. Environmental Impact and Human Health Effects of Polycyclic Aromatic Hydrocarbons and Remedial Strategies: A Detailed Review. Chemosphere 2024, 351, 141227. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  10. Aretaki, M.A.; Desmet, J.; Viana, M.; van Drooge, B.L. Comprehensive Methodology for Semi-Volatile Organic Compound Determination in Ambient Air with Emphasis on Polycyclic Aromatic Hydrocarbons Analysis by GC–MS/MS. J. Chromatogr. A 2024, 1730, 465086. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  11. Jeong, J.; Koo, M.; Lee, J.-G. QuEChERS Method Development for the GC–MS Analysis of Polycyclic Aromatic Hydrocarbons in Food. Food Sci. Biotechnol. 2025, 34, 2749–2761. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  12. Słowik-Borowiec, M.; Szpyrka, E.; Książek-Trela, P.; Podbielska, M. Simultaneous Determination of Multi-Class Pesticide Residues and PAHs in Plant Material and Soil Samples Using the Optimized QuEChERS Method and Tandem Mass Spectrometry Analysis. Molecules 2022, 27, 2140. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  13. Çetintürk, K.; Güzel, B.; Canlı, O. The Development of a Novel, Green, Efficient, and Eco-Friendly GC-MS/MS Analytical Method for the Reliable and Rapid Determination of Dl-PCBs, and PCDD/Fs Using Hydrogen as a Carrier Gas and a Modified Ion Source. Talanta 2025, 283, 127180. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  14. Qin, J.; Tong, K.; Chang, Q.; He, J.; Xie, Y.; Han, X.; Wu, X.; Pei, X.; Shi, M.; Zhang, H.; et al. Simultaneous Determination of PCBs, PAEs, PAHs, and BPs in Oat Grass Using a QuEChERS-Based Method Combined with GC–MS/MS and UPLC-MS/MS. Microchem. J. 2025, 219, 116201. [Google Scholar] [CrossRef] [Scilit]
  15. Rascón, A.J.; Azzouz, A.; Ballesteros, E. Multiresidue Determination of Polycyclic Aromatic Hydrocarbons in Edible Oils by Liquid-Liquid Extraction–Solid-Phase Extraction–Gas Chromatography–Mass Spectrometry. Food Control 2018, 94, 268–275. [Google Scholar] [CrossRef] [Scilit]
  16. Zhang, Q.; Guo, W.; He, L.; He, L.; Chen, Y.; Shen, X.; Wu, D. A New SERS Substrate of Self-Assembled Monolayer Film of Gold Nanoparticles on Silicon Wafer for the Rapid Detection of Polycyclic Aromatic Hydrocarbons. Mater. Chem. Phys. 2020, 250, 122994. [Google Scholar] [CrossRef] [Scilit]
  17. Zhou, Z.; Lu, J.; Wang, J.; Zou, Y.; Liu, T.; Zhang, Y.; Liu, G.; Tian, Z. Trace Detection of Polycyclic Aromatic Hydrocarbons in Environmental Waters by SERS. Spectrochim. Acta A Mol. Biomol. Spectrosc. 2020, 234, 118250. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  18. Onopiuk, A.; Kołodziejczak, K.; Marcinkowska-Lesiak, M.; Poltorak, A. Determination of Polycyclic Aromatic Hydrocarbons Using Different Extraction Methods and HPLC-FLD Detection in Smoked and Grilled Meat Products. Food Chem. 2022, 373, 131506. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  19. Ma, C.-M.; Lin, L.-C.; Chuang, K.-J.; Hong, G.-B. Colorimetric Detection of Polycyclic Aromatic Hydrocarbons by Using Gold Nanoparticles. Spectrochim. Acta A Mol. Biomol. Spectrosc. 2022, 268, 120701. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  20. Lv, Y.; Ma, J.; Yu, Z.; Liu, S.; Yang, G.; Liu, Y.; Lin, C.; Ye, X.; Shi, Y.; Liu, M. Fabrication of Covalent Organic Frameworks Modified Nanofibrous Membrane for Efficiently Enriching and Detecting the Trace Polychlorinated Biphenyls in Water. Water Res. 2023, 235, 119892. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  21. Liu, C.; Yu, H.; Zhang, B.; Liu, S.; Liu, C.; Li, F.; Song, H. Engineering Whole-Cell Microbial Biosensors: Design Principles and Applications in Monitoring and Treatment of Heavy Metals and Organic Pollutants. Biotechnol. Adv. 2022, 60, 108019. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  22. Chen, S.; Chen, X.; Su, H.; Guo, M.; Liu, H. Advances in Synthetic-Biology-Based Whole-Cell Biosensors: Principles, Genetic Modules, and Applications in Food Safety. Int. J. Mol. Sci. 2023, 24, 7989. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  23. Wei, H.; Ze-Ling, S.; Le-Le, C.; Wen-hui, Z.; Chuan-Chao, D. Specific Detection of Bioavailable Phenanthrene and Mercury by Bacterium Reporters in the Red Soil. Int. J. Environ. Sci. Technol. 2014, 11, 685–694. [Google Scholar] [CrossRef] [Scilit]
  24. Moratti, C.F.; Yang, S.N.N.; Scott, C.; Coleman, N.V. Development of a Whole-Cell Biosensor for Ethylene Oxide and Ethylene. Microb. Biotechnol. 2024, 17, e14511. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  25. Ben-Yoav, H.; Biran, A.; Pedahzur, R.; Belkin, S.; Buchinger, S.; Reifferscheid, G.; Shacham-Diamand, Y. A Whole Cell Electrochemical Biosensor for Water Genotoxicity Bio-Detection. Electrochim. Acta 2009, 54, 6113–6118. [Google Scholar] [CrossRef] [Scilit]
  26. Berepiki, A.; Kent, R.; Machado, L.F.M.; Dixon, N. Development of High-Performance Whole Cell Biosensors Aided by Statistical Modeling. ACS Synth. Biol. 2020, 9, 576–589. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  27. Han, L.; Zhao, Y.; Cui, S.; Liang, B. Redesigning of Microbial Cell Surface and Its Application to Whole-Cell Biocatalysis and Biosensors. Appl. Biochem. Biotechnol. 2018, 185, 396–418. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  28. Wang, W.; Xia, J.; Wang, Z.; Shao, Z. Bacterial Cell Sensing and Signaling Pathway for External Polycyclic Aromatic Hydrocarbons (PAHs). iScience 2023, 26, 107912. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  29. Jung, K.; Fabiani, F.; Hoyer, E.; Lassak, J. Bacterial Transmembrane Signalling Systems and Their Engineering for Biosensing. Open Biol. 2018, 8, 180023. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  30. Chen, X.; Yao, H.; Song, D.; Sun, G.; Xu, M. Extracellular Chemoreceptor of Deca-Brominated Diphenyl Ether and Its Engineering in the Hydrophobic Chassis Cell for Organics Biosensing. Chem. Eng. J. 2022, 433, 133266. [Google Scholar] [CrossRef] [Scilit]
  31. Trögl, J.; Ripp, S.; Kuncová, G.; Sayler, G.S.; Churavá, A.; Pařík, P.; Demnerová, K.; Hálová, J.; Kubicová, L. Selectivity of Whole Cell Optical Biosensor with Immobilized Bioreporter Pseudomonas fluorescens HK44. Sens. Actuators B Chem. 2005, 107, 98–103. [Google Scholar] [CrossRef] [Scilit]
  32. Daunert, S.; Barrett, G.; Feliciano, J.S.; Shetty, R.S.; Shrestha, S.; Smith-Spencer, W. Genetically Engineered Whole-Cell Sensing Systems: Coupling Biological Recognition with Reporter Genes. Chem. Rev. 2000, 100, 2705–2738. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  33. King, J.M.H.; DiGrazia, P.M.; Applegate, B.; Burlage, R.; Sanseverino, J.; Dunbar, P.; Larimer, F.; Sayler, G.S. Rapid, Sensitive Bioluminescent Reporter Technology for Naphthalene Exposure and Biodegradation. Science 1990, 249, 778–781. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  34. Shin, D.; Moon, H.S.; Lin, C.-C.; Barkay, T.; Nam, K. Use of Reporter-Gene Based Bacteria to Quantify Phenanthrene Biodegradation and Toxicity in Soil. Environ. Pollut. 2011, 159, 509–514. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  35. Zhang, X.; Li, B.; Schillereff, D.N.; Chiverrell, R.C.; Tefsen, B.; Wells, M. Whole-Cell Biosensors for Determination of Bioavailable Pollutants in Soils and Sediments: Theory and Practice. Sci. Total Environ. 2022, 811, 152178. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  36. Tecon, R.; Beggah, S.; Czechowska, K.; Sentchilo, V.; Chronopoulou, P.-M.; McGenity, T.J.; van der Meer, J.R. Development of a Multistrain Bacterial Bioreporter Platform for the Monitoring of Hydrocarbon Contaminants in Marine Environments. Environ. Sci. Technol. 2010, 44, 1049–1055. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  37. Chen, X.; Wang, H.; Xu, J.; Song, D.; Sun, G.; Xu, M. Sphingobium hydrophobicum sp. nov., a Hydrophobic Bacterium Isolated from Electronic-Waste-Contaminated Sediment. Int. J. Syst. Evol. Microbiol. 2016, 66, 3912–3916. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  38. Kohlmeier, S.; Mancuso, M.; Tecon, R.; Harms, H.; van der Meer, J.R.; Wells, M. Bioreporters: Gfp versus Lux Revisited and Single-Cell Response. Biosens. Bioelectron. 2007, 22, 1578–1585. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  39. Tecon, R.; Wells, M.; van der Meer, J.R. A New Green Fluorescent Protein-Based Bacterial Biosensor for Analysing Phenanthrene Fluxes. Environ. Microbiol. 2006, 8, 697–708. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  40. Valdman, E.; Battaglini, F.; Leite, S.G.F.; Valdman, B. Naphthalene Detection by a Bioluminescence Sensor Applied to Wastewater Samples. Sens. Actuators B Chem. 2004, 103, 7–12. [Google Scholar] [CrossRef] [Scilit]
  41. Layton, A.C.; Muccini, M.; Ghosh, M.M.; Sayler, G. Construction of a Bioluminescent Reporter Strain to Detect Polychlorinated Biphenyls. Appl. Environ. Microbiol. 1998, 64, 5023–5026. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  42. Turner, K.; Xu, S.; Pasini, P.; Deo, S.; Bachas, L.; Daunert, S. Hydroxylated Polychlorinated Biphenyl Detection Based on a Genetically Engineered Bioluminescent Whole-Cell Sensing System. Anal. Chem. 2007, 79, 5740–5745. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  43. Laurie, A.D.; Lloyd-Jones, G. The Phn Genes of Burkholderiasp. Strain RP007 Constitute a Divergent Gene Cluster for Polycyclic Aromatic Hydrocarbon Catabolism. J. Bacteriol. 1999, 181, 531–540. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  44. Schell, M.A.; Brown, P.H.; Raju, S. Use of Saturation Mutagenesis to Localize Probable Functional Domains in the NahR Protein, a LysR-Type Transcription Activator. J. Biol. Chem. 1990, 265, 3844–3850. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  45. Yen, K.-M.; Serdar, C.M.; Gunsalus, I.C. Genetics of Naphthalene Catabolism in Pseudomonads. CRC Crit. Rev. Microbiol. 1988, 15, 247–268. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  46. Furukawa, K. Molecular Genetics and Evolutionary Relationship of PCB-Degrading Bacteria. Biodegradation 1994, 5, 289–300. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  47. Lajoie, C.A.; Layton, A.C.; Sayler, G.S. Cometabolic Oxidation of Polychlorinated Biphenyls in Soil with a Surfactant-Based Field Application Vector. Appl. Environ. Microbiol. 1994, 60, 2826–2833. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  48. Erickson, B.D.; Mondello, F.J. Nucleotide Sequencing and Transcriptional Mapping of the Genes Encoding Biphenyl Dioxygenase, a Multicomponent Polychlorinated-Biphenyl-Degrading Enzyme in Pseudomonas Strain LB400. J. Bacteriol. 1992, 174, 2903–2912. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  49. Roggo, C.; van der Meer, J.R. Miniaturized and Integrated Whole Cell Living Bacterial Sensors in Field Applicable Autonomous Devices. Curr. Opin. Biotechnol. 2017, 45, 24–33. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  50. Jumper, J.; Evans, R.; Pritzel, A.; Green, T.; Figurnov, M.; Ronneberger, O.; Tunyasuvunakool, K.; Bates, R.; Žídek, A.; Potapenko, A.; et al. Highly Accurate Protein Structure Prediction with AlphaFold. Nature 2021, 596, 583–589. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  51. Varadi, M.; Anyango, S.; Deshpande, M.; Nair, S.; Natassia, C.; Yordanova, G.; Yuan, D.; Stroe, O.; Wood, G.; Laydon, A.; et al. AlphaFold Protein Structure Database: Massively Expanding the Structural Coverage of Protein-Sequence Space with High-Accuracy Models. Nucleic Acids Res. 2022, 50, D439–D444. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  52. Dhyani, R.; Jain, S.; Bhatt, A.; Kumar, P.; Navani, N.K. Genetic Regulatory Element Based Whole-Cell Biosensors for the Detection of Metabolic Disorders. Biosens. Bioelectron. 2022, 199, 113869. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  53. Shimomura, O.; Johnson, F.H.; Saiga, Y. Extraction, Purification and Properties of Aequorin, a Bioluminescent Protein from the Luminous Hydromedusan, Aequorea. J. Cell. Comp. Physiol. 1962, 59, 223–239. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  54. Cubitt, A.B.; Heim, R.; Adams, S.R.; Boyd, A.E.; Gross, L.A.; Tsien, R.Y. Understanding, Improving and Using Green Fluorescent Proteins. Trends Biochem. Sci. 1995, 20, 448–455. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  55. Zeng, N.; Wu, Y.; Chen, W.; Huang, Q.; Cai, P. Whole-Cell Microbial Bioreporter for Soil Contaminants Detection. Front. Bioeng. Biotechnol. 2021, 9, 622994. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  56. Close, D.; Xu, T.; Smartt, A.; Rogers, A.; Crossley, R.; Price, S.; Ripp, S.; Sayler, G. The Evolution of the Bacterial Luciferase Gene Cassette (Lux) as a Real-Time Bioreporter. Sensors 2012, 12, 732–752. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  57. Meighen, E.A. Enzymes and Genes from the Lux Operons of Bioluminescent Bacteria. Annu. Rev. Microbiol. 1988, 42, 151–176. [Google Scholar] [CrossRef]
  58. Engebrecht, J.; Simon, M.; Silverman, M. Measuring Gene Expression with Light. Science 1985, 227, 1345–1347. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  59. Crivat, G.; Taraska, J.W. Imaging Proteins inside Cells with Fluorescent Tags. Trends Biotechnol. 2012, 30, 8–16. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  60. Heitzer, A.; Applegate, B.; Kehrmeyer, S.; Pinkart, H.; Webb, O.F.; Phelps, T.J.; White, D.C.; Sayler, G.S. Physiological Considerations of Environmental Applications of Lux Reporter Fusions. J. Microbiol. Methods 1998, 33, 45–57. [Google Scholar] [CrossRef] [Scilit]
  61. Xu, T.; Close, D.M.; Sayler, G.S.; Ripp, S. Genetically Modified Whole-Cell Bioreporters for Environmental Assessment. Ecol. Indic. 2013, 28, 125–141. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  62. Roda, A.; Guardigli, M.; Michelini, E.; Mirasoli, M. Bioluminescence in Analytical Chemistry and in Vivo Imaging. TrAC Trends Anal. Chem. 2009, 28, 307–322. [Google Scholar] [CrossRef] [Scilit]
  63. Sticher, P.; Jaspers, M.C.; Stemmler, K.; Harms, H.; Zehnder, A.J.; van der Meer, J.R. Development and Characterization of a Whole-Cell Bioluminescent Sensor for Bioavailable Middle-Chain Alkanes in Contaminated Groundwater Samples. Appl. Environ. Microbiol. 1997, 63, 4053–4060. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  64. Song, Y.; Li, G.; Thornton, S.F.; Thompson, I.P.; Banwart, S.A.; Lerner, D.N.; Huang, W.E. Optimization of Bacterial Whole Cell Bioreporters for Toxicity Assay of Environmental Samples. Environ. Sci. Technol. 2009, 43, 7931–7938. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  65. Burlage, R.S.; Sayler, G.S.; Larimer, F. Monitoring of Naphthalene Catabolism by Bioluminescence with Nah-Lux Transcriptional Fusions. J. Bacteriol. 1990, 172, 4749–4757. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  66. Heitzer, A.; Webb, O.F.; Thonnard, J.E.; Sayler, G.S. Specific and Quantitative Assessment of Naphthalene and Salicylate Bioavailability by Using a Bioluminescent Catabolic Reporter Bacterium. Appl. Environ. Microbiol. 1992, 58, 1839–1846. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  67. Heitzer, A.; Malachowsky, K.; Thonnard, J.E.; Bienkowski, P.R.; White, D.C.; Sayler, G.S. Optical Biosensor for Environmental On-Line Monitoring of Naphthalene and Salicylate Bioavailability with an Immobilized Bioluminescent Catabolic Reporter Bacterium. Appl. Environ. Microbiol. 1994, 60, 1487–1494. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  68. Shin, H.J. Development of Highly-Sensitive Microbial Biosensors by Mutation of the nahR Regulatory Gene. J. Biotechnol. 2010, 150, 246–250. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  69. Sun, Y.; Zhao, X.; Zhang, D.; Ding, A.; Chen, C.; Huang, W.E.; Zhang, H. New Naphthalene Whole-Cell Bioreporter for Measuring and Assessing Naphthalene in Polycyclic Aromatic Hydrocarbons Contaminated Site. Chemosphere 2017, 186, 510–518. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  70. Werlen, C.; Jaspers, M.C.M.; van der Meer, J.R. Measurement of Biologically Available Naphthalene in Gas and Aqueous Phases by Use of a Pseudomonas Putida Biosensor. Appl. Environ. Microbiol. 2004, 70, 43–51. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  71. Singh, M.; Mradula; Lal, N. An Overview on Bioreporter Development for Pollution Monitoring. J. Appl. Microbiol. 2023, 134, lxad220. [Google Scholar] [CrossRef]
  72. Robbens, J.; Dardenne, F.; Devriese, L.; De Coen, W.; Blust, R. Escherichia coli as a Bioreporter in Ecotoxicology. Appl. Microbiol. Biotechnol. 2010, 88, 1007–1025. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  73. Huang, W.E.; Wang, H.; Zheng, H.; Huang, L.; Singer, A.C.; Thompson, I.; Whiteley, A.S. Chromosomally Located Gene Fusions Constructed in Acinetobacter sp. ADP1 for the Detection of Salicylate. Environ. Microbiol. 2005, 7, 1339–1348. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  74. Sharma, D.; Parashar, A.; Sharma, D.; Attri, S.; Chaudhary, A. Microbial Sensors: A Tool for Accelerating Sustainable Green Technologies. In Microbial Approaches for Sustainable Green Technologies; CRC Press: Boca Raton, FL, USA, 2024; ISBN 978-1-003-40768-3. [Google Scholar]
  75. Deng, C.; Wu, Y.; Lv, X.; Li, J.; Liu, Y.; Du, G.; Chen, J.; Liu, L. Refactoring Transcription Factors for Metabolic Engineering. Biotechnol. Adv. 2022, 57, 107935. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  76. Wang, H.; Sheng, Y.; Ou, Y.; Xu, M.; Tao, M.; Lin, S.; Deng, Z.; Bai, L.; Ding, W.; Kang, Q. Streptomyces-Based Whole-Cell Biosensors for Detecting Diverse Cell Envelope-Targeting Antibiotics. Biosens. Bioelectron. 2024, 249, 116004. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  77. Lopreside, A.; Calabretta, M.M.; Montali, L.; Zangheri, M.; Guardigli, M.; Mirasoli, M.; Michelini, E. Bioluminescence Goes Portable: Recent Advances in Whole-Cell and Cell-Free Bioluminescence Biosensors. Lumin. J. Biol. Chem. Lumin. 2021, 36, 278–293. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  78. Perez, J.G.; Stark, J.C.; Jewett, M.C. Cell-Free Synthetic Biology: Engineering Beyond the Cell. Cold Spring Harb. Perspect. Biol. 2016, 8, a023853. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  79. Shimizu, Y.; Kanamori, T.; Ueda, T. Protein Synthesis by Pure Translation Systems. Methods 2005, 36, 299–304. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  80. Schirmer, C.; Posseckardt, J.; Kick, A.; Rebatschek, K.; Fichtner, W.; Ostermann, K.; Schuller, A.; Rödel, G.; Mertig, M. Encapsulating Genetically Modified Saccharomyces cerevisiae Cells in a Flow-through Device towards the Detection of Diclofenac in Wastewater. J. Biotechnol. 2018, 284, 75–83. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  81. Cao, Y.; Zhang, B.; Zhu, Z.; Xin, X.; Wu, H.; Chen, B. Microfluidic Based Whole-Cell Biosensors for Simultaneously On-Site Monitoring of Multiple Environmental Contaminants. Front. Bioeng. Biotechnol. 2021, 9, 622108. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  82. Chen, J.; Shi, G.; Yan, C. Portable Biosensor for On-Site Detection of Kanamycin in Water Samples Based on CRISPR-Cas12a and an off-the-Shelf Glucometer. Sci. Total Environ. 2023, 872, 162279. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  83. Karaboğa, S.; Nur, M. Sensitive Detection of DJ-1 in Artificial Cerebrospinal Fluid Using a Portable GPTMS-Coordinated Gold Nanoparticle-Based Biosensor. Biosensors 2026, 16, 146. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  84. Shen, Y.; Chai, S.; Zhang, Q.; Zhang, M.; Mao, X.; Wei, L.; Zhou, F.; Sun, R.; Liu, C. PVF Composite Conductive Nanofibers-Based Organic Electrochemical Transistors for Lactate Detection in Human Sweat. Chem. Eng. J. 2023, 475, 146008. [Google Scholar] [CrossRef] [Scilit]
  85. Zhang, L.; Du, Y.; Li, H.; Yan, S.; Yao, Q.; Liu, C.; Zhang, Y.; Zhu, X. Wearable Multifunctional Sensors for Human Activity Recognition. Sensors 2026, 26, 3420. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  86. Sun, X.; Xiang, Y.; Liu, M.; Xu, X.; Zhang, L.; Zhuang, L.; Wang, P.; Wang, Q. High-Performance and -Efficiency Cardiomyocyte-Based Potential Biosensor for Temporal-Specific Detection of Ion Channel Marine Toxins. Biosens. Bioelectron. 2023, 220, 114837. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  87. Tam, C.C.; Du, W.-X.; Wang, Y.; Flannery, A.R.; He, X. Rapid and Sensitive Detection of Shiga Toxin-Producing Escherichia coli (STEC) from Food Matrices Using the CANARY Biosensor Assay. Toxins 2024, 16, 325. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  88. Yuan, M.; Li, C.; Zheng, Y.; Cao, H.; Ye, T.; Wu, X.; Hao, L.; Yin, F.; Yu, J.; Xu, F. A Portable Multi-Channel Fluorescent Paper-Based Microfluidic Chip Based on Smartphone Imaging for Simultaneous Detection of Four Heavy Metals. Talanta 2024, 266, 125112. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  89. Skotadis, E.; Tsigkourakos, M.; Anthoulakis, E.; Filippidou, M.-K.; Ntouskas, S.; Kainourgiaki, M.; Tsioustas, C.; Panagopoulou, C.; Dimou-Sakellariou, S.; Kalatzis, N.; et al. Development of Advanced Nanobiosensors and a Portable Monitoring System for Pesticide Detection at the Point of Need. Biosensors 2026, 16, 109. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  90. Selim, A.S.; Perry, J.M.; Nasr, M.A.; Pimprikar, J.M.; Shih, S.C.C. A Synthetic Biosensor for Detecting Putrescine in Beef Samples. ACS Appl. Bio Mater. 2022, 5, 5487–5496. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  91. Pi, S.; Feng, L.; Wang, Q.; Yang, W.; Yu, S.; Li, Z.; Gao, X.; Lu, L. Visual Detection of Collective Highly Toxic Metals in Water by a Handheld Whole-Cell Biosensing Detector: From Circuit to Field. iScience 2026, 29, 115289. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  92. Rozas, P.; Kessi-Pérez, E.I.; Martínez, C. Genetically Modified Organisms: Adapting Regulatory Frameworks for Evolving Genome Editing Technologies. Biol. Res. 2022, 55, 31. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  93. Ma, Y.; Manna, A.; Moon, T.S. Advances in Engineering Genetic Circuits for Microbial Biocontainment. Curr. Opin. Syst. Biol. 2023, 36, 100483. [Google Scholar] [CrossRef] [Scilit]
  94. Varma, S.; Gulati, K.A.; Sriramakrishnan, J.; Ganla, R.K.; Raval, R. Environment Signal Dependent Biocontainment Systems for Engineered Organisms: Leveraging Triggered Responses and Combinatorial Systems. Synth. Syst. Biotechnol. 2025, 10, 356–364. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  95. Chemla, Y.; Sweeney, C.J.; Wozniak, C.A.; Voigt, C.A. Design and Regulation of Engineered Bacteria for Environmental Release. Nat. Microbiol. 2025, 10, 281–300. [Google Scholar] [CrossRef] [Scilit] [PubMed]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.