Abstract
Francis turbines are renowned for their high efficiency and adaptability across a wide range of head and discharge conditions. However, internal mechanical friction losses (IMFLs), resulting from rotational frictional resistance between the rotating runner and the surrounding fluid, remain a significant obstacle to further performance optimisation. This study introduced a CFD-derived integral friction torque framework, validated through theoretical analysis, that enables the spatially resolved quantification of IMFLs in Francis turbine runners. Building on this framework, a comprehensive computational approach was established to quantify IMFLs in a Francis turbine runner using a CFD-derived integral torque method combined with a theoretical verification model. Three runner configurations were analysed: the original runner model (ORM), a modified runner (RM1) with selective exit height reduction, and a modified runner (RM2) with uniform exit height reduction. Transient simulations were conducted at the best efficiency point (BEP) using the shear stress transport (SST) k–ω turbulence model and a sliding mesh approach. The numerical results were verified using the theoretical model and systematically evaluated to assess IMFL mechanisms and runner performance. The findings demonstrate that variations in runner geometry significantly influence internal frictional resistance and turbine efficiency. Compared with ORM, both RM1 and RM2 reduced the rotational friction torque, with RM2 exhibiting the greatest improvement: a 2.83% reduction in total friction resistance torque, a 14.74% reduction in total power losses, and a 1% absolute increase in efficiency. These improvements are primarily attributed to reduced wall shear stress and a more uniform pressure distribution across the runner surface.
1. Introduction
As the global energy transition accelerates, improving the performance and efficiency of hydropower has become a strategic priority to maximise energy recovery while minimising environmental impact. Among the hydraulic turbines, Francis turbines play a central role due to their operational flexibility across a wide range of heads and flow rates, making them the preferred choice for medium- and high-head hydropower plants [1,2,3]. Their widespread application is largely attributed to their robust design and ability to maintain stable performance under varying load conditions.
Although technologically advanced, the internal flow behaviour of Francis turbines is complex, particularly in transient or off-design operating conditions. Previous studies have shown that flow separation, vortex formation, secondary circulation, and backflow can significantly intensify internal energy dissipation, leading to reduced hydraulic efficiency and increased internal mechanical friction losses (IMFLs) [4,5,6]. These loss mechanisms are closely linked to the interaction between the rotating runner and the surrounding fluid, where wall shear stresses and pressure gradients play a dominant role.
To systematically investigate these phenomena, a series of coordinated experimental and numerical benchmark studies was conducted within the Francis-99 workshops organised by the Norwegian University of Science and Technology (NTNU) in collaboration with Luleå University of Technology (LTU) [7,8,9]. These initiatives provided high-quality experimental measurements, validated geometries, and well-defined operating conditions, establishing a reliable reference framework for evaluating numerical modelling approaches applied to Francis turbines.
Building on the Francis turbine’s subsequent experimental and high-fidelity CFD studies, detailed insights into complex internal flow structures, including vortex cores, boundary layer separation, draft tube backflow, and pressure pulsations, particularly under part-load and overload conditions were obtained [10,11,12,13,14]. While these investigations significantly advanced the understanding of turbine flow physics and hydraulic performance, they primarily focused on global efficiency, pressure fluctuations, and unsteady flow features. Trivedi, Cervantes, and Liu et al. [7,15,16,17] demonstrated that high-resolution CFD modelling can accurately capture runner–stator interactions and the development of turbulent flow structures in Francis turbines. Their work highlighted the capability of advanced numerical methods to resolve complex unsteady flow features that strongly influence turbine performance. Nevertheless, despite these advances, several loss mechanisms associated with flow interaction and transient behaviour remain insufficiently resolved, limiting a comprehensive understanding of performance degradation under off-design conditions. Experimental and numerical studies have reported that unaccounted flow dynamics can lead to efficiency deviations exceeding 11% at partial-load operation, even when best efficiency point (BEP) efficiencies approach 92%. These losses have been linked to rotating vortex ropes, draft-tube pressure fluctuations, and enhanced energy dissipation during off-design operation [18,19,20,21].
Most existing studies have primarily focused on improving hydraulic performance through geometric optimisation or flow-control strategies, while IMFLs remain comparatively under-characterised. Chen and Liu et al. [22,23] introduced the geometric optimisation of runner blades using parametric methods, reporting improvements in pressure recovery and efficiency. Thapa and Shrestha et al. [24,25] developed and improved methods for blade profiles to mitigate sediment erosion, whereas Lu Jun et al. [26] applied finite-element-based optimisation techniques to enhance structural strength. In parallel, advanced vortex identification approaches, including the Liutex method, have been introduced to improve the analysis of complex rotational flow structures (Tran et al.) [27,28]. Although these studies contribute valuable insights into flow behaviour and structural performance, they do not explicitly quantify friction-induced losses within rotating components.
Further investigations by Zhou et al. [29] examined pressure recovery, boundary layer separation, and their influence on turbine capacity. However, evaluating performance solely through global pressure or head differences provides limited information on the spatial distribution of internal losses, particularly those arising from wall shear friction. Joy and Yu et al. [30,31] showed that relatively small load variations can induce efficiency reductions exceeding 10% under part-load conditions, while Minakov et al. [32] reported substantial increases in internal losses during start-up and load transitions due to interactions between vortical structures and rotating walls. More recent efforts have focused on diagnostic and monitoring techniques, including uncertainty-aware online analysis systems [33], the prototype-scale efficiency testing method [34], and CFD-assisted diagnostic tools for performance evaluation [35,36]. While these approaches enhance the precision of turbine performance evaluation, the advancements primarily focus on total losses and do not quantitatively determine the frictional dissipation within rotating components.
Foundational theoretical work by Zhuo Ma, Xiao Hui, and Cheng Yuan [37,38,39] established key relationships between flow velocity, passage geometry, surface roughness, and hydraulic losses, demonstrating that increased flow velocities amplify both impact and frictional dissipation. Building on this foundation, Zeng Yun and his group [40,41,42] developed energy-balance models that account for mechanical, volumetric, and hydraulic losses. Their results indicated that internal friction losses can contribute more than 5% to efficiency reduction under part-load operation, underscoring the importance of accurately characterising friction-related dissipation in hydraulic machines.
Recent advances in CFD have enabled increasingly detailed spatial resolution of loss mechanisms within hydraulic turbines [43]. High-fidelity simulations now allow turbine performance to be derived directly from local torque and velocity fields across operating conditions. Studies by Jiyun et al. [44] and Huang et al. [45] demonstrated that incorporating blade outlet geometry, draft-tube vortex structures, disk friction, and leakage losses improved predictive accuracy, particularly under off-design conditions. In the same way, Jianjun Feng et al. [46] identified elevated wall shear stresses and backflow regions near the hub and blade trailing edges that significantly intensify frictional losses. Throughout these advances, the quantitative understanding of IMFL remains limited, particularly regarding its location within runner components and its impact on overall efficiency. Many studies continue to rely on simplified or uniform wall-shear assumptions, which do not adequately represent the complex interactions between rotating surfaces and the surrounding flow. Moreover, comprehensive CFD-based IMFL analyses for high-head Francis turbines operating under realistic conditions remain scarce.
To address these gaps, the present study proposes an integrated CFD-based friction-resistance torque framework to evaluate internal mechanical friction losses (IMFLs) in the Francis-99 turbine. High-fidelity transient simulations were performed under best-efficiency-point (BEP) conditions to resolve detailed wall-shear stress and pressure distributions within the rotating domain. The viscous shear stresses on all wetted runner surfaces were numerically integrated to compute the total friction resistance torque, while a complementary theoretical model was employed to validate the CFD results and clarify the combined influence of surface geometry, flow velocity, and fluid viscosity on friction-induced power loss. Three runner configurations were investigated: the original runner model (ORM), a selectively modified model (RM1), and a uniformly modified model (RM2). A systematic comparative analysis was conducted to quantify the effects of geometric modification on friction-torque distribution, local flow behaviour, and overall turbine performance.
The primary contribution of this work lies in coupling CFD-derived torque integration with a validated theoretical friction model to enable spatially resolved quantification of IMFLs in hydraulic turbines. By explicitly resolving viscous torque generation and associated energy dissipation within the runner, the proposed framework advances conventional performance evaluation beyond global efficiency metrics and provides a physically grounded basis for friction-aware runner optimisation.
2. Geometry and Numerical Model
Figure 1 illustrates the overall methodological workflow of the proposed CFD-based integral torque analysis and theoretical framework used to quantify internal mechanical friction losses and assess the performance of the modified runner configurations.
Figure 1.
Methodological workflow of the numerical and theoretical IMFL evaluation framework.
2.1. Description of the Turbine
This study used the Francis-99 turbine model as a test case. It consists of a spiral casing with 14 stay vanes and 28 guide vanes, along with a runner comprising 15 full blades and 15 splitter blades, and an elbow-type draft tube located downstream of the runner. The complete computational domain, shown in Figure 2, can be divided into three regions: the stationary distributor domain, the rotating runner domain, and the stationary draft tube domain. The Francis-99 workshop held at NTNU provides access to validated experimental measurements, boundary conditions, and comprehensive CAD geometry for this turbine, which was installed at the hydropower laboratory at NTNU, Norway [47]. The experimental setup consisted of a closed-loop test rig with accurate instrumentation for measuring mechanical, electrical, and hydraulic parameters under steady-state conditions. Table 1 summarises the key experimental parameters of the Francis-99 turbine under steady-state operation at the best efficiency point (BEP). These parameters define the reference operating condition used throughout the present study, including discharge, net head, rotational speed, torque, and hydraulic efficiency. The reported inlet and outlet pressure values provide boundary-condition benchmarks for the numerical simulations, while the measured torque and efficiency serve as validation metrics for assessing the accuracy of the CFD–theoretical framework. All numerical simulations presented in this work were conducted under these operating conditions to ensure consistency with the available experimental data.
Figure 2.
Francis-99 turbine geometry model and computational domain.
Table 1.
Experimentally acquired parameters under steady-state operating conditions [47].
2.2. Runner Modification Principle
The runner structure, as specified, consists of an integrated hub with a runner cone and shroud, as well as full blades and splitter blades that are positioned within the runner. The runner features an outlet diameter of 0.349 m. The runner is critical to the efficient extraction of power because its design influences the flow characteristics of the fluid through the blade passages, which are designed to provide the most direct path from the runner inlet to the runner outlet. The primary source of IMFL (induced mechanical frictional loss) within the runner is the friction loss resulting from the resistance torque generated by the friction between the water mass and the runner blades. To minimise these losses, the original runner outlet geometry was modified using two different methods to create a reduced contact area between the rotating runner blades and the surrounding water while maintaining the runner’s general shape and constant exit diameter.
Firstly, in the selective reduction strategy (RM1), the runner exit heights at the end of long blades and were reduced by 18 mm, while the cone height remained unchanged.
Secondly, in the unified reduction strategy (RM2), this time, all three heights, , and , were reduced uniformly by 18 mm. Figure 3 illustrates the specific locations of these modifications, and the different heights at the runner’s exit are listed in Table 2.
Figure 3.
Runner shape modification.
Table 2.
Strategies for modifying the exit height of the runner.
2.3. Grid Generation
Numerically accurate simulations of turbomachinery flows require robust grids capable of resolving complex geometries and near-wall boundary layers. To address the geometric complexity and transient flow characteristics of the Francis-99 turbine, a poly–hex core meshing strategy was adopted. The computational mesh was generated using the volumetric grid subdivision tool in ANSYS Fluent Meshing, resulting in a hybrid grid composed of hexahedral, polyhedral, and prismatic elements. A mesh containing approximately 13 million cells was selected for the simulations, as illustrated in Figure 4. Also, Figure 4 presents the grid independence analysis performed for the numerical simulations. Key performance indicators were evaluated as a function of mesh resolution to assess the sensitivity of the solution to grid refinement. The results demonstrate that beyond a certain mesh density, further refinement led to negligible variations in the predicted quantities, indicating numerical convergence. Based on this analysis, the selected grid resolution was deemed sufficient to accurately capture the flow physics and friction-related phenomena investigated in this study. Prismatic layers were applied along all no-slip walls to resolve near-wall velocity gradients and boundary layer development. Hexahedral elements were used in bulk-flow regions to limit cell count, while polyhedral transitional cells ensured smooth connectivity between different mesh types. Table 3 summarises the grid configurations considered in the present study, including the number of elements used for each computational domain. These grid cases were designed to assess mesh sensitivity and ensure that the numerical results were independent of spatial discretisation. By systematically refining the mesh, an optimal grid resolution was identified that provides a balance between computational efficiency and solution accuracy. The selected grid was subsequently adopted for all simulations to ensure consistency across the analysed runner configurations.
Figure 4.
The poly-hexcore mesh of the computational domain.
Table 3.
The mesh number of numerical simulation domains for the original and modified models.
2.4. Boundary Conditions and Solver Setup
The fluid domain was modelled using the full 360° geometry of the Francis-99 turbine. A mass-flow inlet boundary condition was imposed at the spiral casing entrance, while a pressure-outlet condition was applied at the draft tube exit, as illustrated in Figure 2. The corresponding operating parameters are summarised in Table 4. These boundary conditions are widely adopted in hydraulic turbomachinery simulations and ensure a realistic representation of turbine operating behaviour. The incompressible Reynolds-Averaged Navier–Stokes (RANS) equations were solved using the SIMPLE pressure–velocity coupling algorithm. Spatial discretisation was performed using a high-resolution scheme, and temporal integration employed a second-order backward Euler method to enhance numerical accuracy. The interaction between the rotating runner and stationary components was resolved using the Sliding Mesh Model (SMM), enabling the accurate capture of transient rotor–stator interaction effects. Turbulence was modelled using the SST k–ω model with all-y+ wall treatment, providing reliable near-wall flow resolution. The mesh included five prism layers adjacent to no-slip wall boundaries, with a first-layer thickness corresponding to optimal y+ values. A transition ratio of 0.15 and a growth rate of 1.2 were adopted to ensure smooth boundary-layer resolution and numerical stability. Transient simulations were performed using a time step corresponding to 1° of runner rotation, equivalent to approximately 0.0005 s per step. This temporal resolution ensured adequate capture of unsteady flow structures while maintaining computational efficiency.
Table 4.
Operating boundary conditions for the Francis turbine simulation.
All CFD simulations were conducted using ANSYS Fluent 2023 R1 in double-precision mode. Computations were performed on a high-performance workstation equipped with an Intel® Core™ i9 processor and 128 GB RAM operating under a 64-bit Windows environment.
2.5. Grid Validation
A grid independence study was performed using six mesh configurations with increasing grid density, as summarised in Table 5. The total number of elements ranged from approximately 8.6 million to 14.2 million. As the present study focused on internal mechanical friction losses associated with blade–fluid interaction within the rotating domain, mesh refinement was primarily applied to the runner and stay–guide vane regions from the third grid configuration onward. Grid validation was conducted at the best efficiency point (BEP) by examining the convergence behaviour of net head and generator torque with increasing mesh density. As shown in Table 5, both parameters increased with grid refinement and stabilised once the total grid size exceeded approximately 12 million elements. The variations in net head and torque between the 12 million, 13 million, and 14 million cell grids were negligible, indicating that numerical convergence had been achieved. Based on this analysis, a mesh resolution of approximately 13 million cells was selected for all subsequent simulations, as it provides an optimal balance between numerical accuracy and computational efficiency while ensuring reliable resolution of the flow and friction-related phenomena.
Table 5.
Statistics of grid number for Francis-99 components.
3. Mathematical Models
3.1. Computational Approach
In a Francis turbine, the primary sources of internal energy losses are viscous shear stresses that act on both the rotating and stationary walls, such as the runner blades, hub, shroud, and other wet surfaces. These shear stresses arise from the velocity gradient between the fluid and the solid boundaries, leading to a continuous exchange of momentum. As a result, some of the mechanical energy is transformed into heat through viscous dissipation, also known as IMFL.
The local wall shear stress can be described as:
For the rotating runner, the resulting frictional force generates a torque that opposes rotation:
where is the wall shear stress, represents the effective viscosity, is the position vector from the rotation axis, and represents the surface area of the runner.
The runner assembly consists of four primary components: the blades, hub, shroud, and runner cone. Based on Equation (2), the frictional torque for each surface can be evaluated individually using the CFD-based surface integrals below, allowing for a detailed quantification of the IMFL associated with each component.
For the blades:
For the hub:
For the shroud:
For the runner cone:
Total rotational resistance torque:
where are the wall shear stresses in the and directions, respectively; and denote the local coordinate axes at the point of calculation, and is the differential surface area element over which the shear stresses are integrated.
3.2. Theoretical Validation Framework
A theoretical analysis of total loss was conducted to verify the physical accuracy of internal losses estimated using CFD-derived data. Figure 5 reveals that the rotating wetted surfaces of the runner can be divided into four major parts: the blade leading edge, the bottom ring, the runner cone, and the blade trailing edge. These surfaces interact with the surrounding fluid during operation, collectively influencing the IMFL within the Francis turbine runner. The shear action between the rotating surface and the fluid generates a frictional resistance torque, which reduces the turbine’s effective power output.
Figure 5.
Rotating component friction surfaces in the Francis-99 turbine runner.
3.2.1. Mechanical Friction Loss
By using the internal energy equation of a hydro turbine, as described in Reference [41], evaluating internal energy becomes vital in understanding the processes involved in the transformation of system energies. The internal energy equation considers interactions related to energy between fluids and turbine systems, with a primary focus on internal power loss and heat release due to fluid dynamics described by Equation (8). Internal energy evaluation helps determine the primary causes of efficiency loss in turbines.
Equations (9) and (10) describe a quantitative evaluation of power loss due to flow resistance in the runner passageways and volumetric loss, respectively. Under optimal operation, the water flow at the inlet of the runner remains constant, while the direction of the outflow corresponds to that expected at the outlet of the runner. It can therefore be assumed that the impact loss at optimal efficiency operation is zero (). These equations were substituted into Equation (8) with the result described in Equation (11) below:
where represents the loss coefficient associated with flow resistance in the runner channels. For modern large hydro turbines, the volumetric loss coefficient typically ranges from 0.0025 to 0.005. In the present analysis, was assumed to be zero, indicating that it has no significant effect [42]. Thus, , and the corresponding coefficient was calculated over ten increments, resulting in an average value of = 60.4641. Using this parameter and the simplified formula of Equation (11), the mechanical friction losses can be evaluated according to the given formula:
3.2.2. Frication Resistance Torque
To evaluate the frictional torque acting on the wet surfaces of the Francis turbine runner, the local shear stress on each surface was measured to determine the amount of torque caused by frictional resistance. The runner surfaces were discretised into finite elements, and the Prandtl–Schlichting boundary layer theory was applied to approximate the frictional resistance coefficient under rotational motion. This framework captures the localised change of friction along the rotating surfaces, allowing for a precise estimation of the internal friction torque and enabling a comparison with results obtained from CFD.
The wall shear stress acting on the rotating runner surfaces is expressed as:
where is the angular velocity of the runner and denotes the local radial distance from the axis of rotation. This formulation relates the shear stress directly to the local tangential velocity induced by rotational motion.
The friction coefficient was evaluated using the Prandtl–Schlichting formulation for turbulent boundary layers on rotating surfaces, given by:
where and are empirical constants.
The local Reynolds number characterising the rotational flow is defined as:
with denoting the fluid density and the dynamic viscosity. Equations (14) and (15) together enable the determination of the friction coefficient associated with each rotating surface element.
The frictional resistance torque acting on an infinitesimal surface element of the runner can then be expressed as:
where represents the wetted surface area of the element.
Considering a finite surface element at the inlet surface of the runner (blade trailing edge) with local radius , and wetted surface area , the differential friction torque is obtained as:
The same integration procedure was subsequently applied to the remaining rotating surfaces, including the bottom ring and the runner cone, to obtain their respective contributions to the total frictional resistance torque:
The outlet runner edge (blade trailing edge), located at the point where water exits the runner, exhibits a conical or sloped configuration. The approximation is represented as a linear function connecting two radii, and . As a result, the outlet region is considered a conical frustum. The wet surface area is determined by the surface element of the cone, and the radius r varies linearly between and . Then, the friction resistance torque can be calculated as:
The total friction resistance torque is the sum of the friction losses in the runner section, which are the IMFLs occurring in the Francis turbine runner.
where represents the wall shear stress N·m−2; represents the angular speed in rad; s−1, represents the specific weight of water, kN·m−3; represents the distance from the finite element to the axis; represents the friction resistance torque in Nm; represents the viscosity resistance coefficient; represents the Reynolds number; represents the friction surface height in m; and represents a specific location in the analysis. Referring to [42], is the undetermined coefficient, 1.005 × 10−3 N·s·m−2 represents the dynamic viscosity at a water temperature of 20 °C.
4. Results and Discussion
Transient simulations were conducted at the best efficiency point (BEP) using the shear stress transport (SST) k–ω turbulence model and a sliding mesh approach, along with the CFD-derived integral torque method for all configurations. The integrated computational model was verified using the theoretical model. The results were systematically evaluated to assess IMFL mechanisms and runner performance; the findings clarify how variations in runner geometry affect internal frictional resistance and turbine efficiency.
The numerical results were validated against the experimental measurements, as summarised in Table 6. The predicted generator torque and net head exhibited relative deviations of 4.9% and 2.17%, respectively. These values fall within the accuracy range commonly reported for CFD simulations of Francis turbines, where discrepancies of up to 5–10% are generally considered acceptable due to uncertainties related to turbulence modelling, wall roughness representation, and experimental torque measurements [9,32]. The hydraulic efficiency showed a deviation of only 0.98%, indicating that the numerical model accurately captures the dominant energy conversion processes at BEP. In previous CFD validation studies of hydraulic turbines, efficiency differences below 1–2% were typically regarded as satisfactory for steady operating conditions. The casing inlet pressure was predicted with a relative error of 2.5%, which is well within the range reported in the literature for pressure validation in hydraulic turbomachinery. The larger deviation observed at the draft tube outlet (8.8%) can be primarily attributed to the presence of complex, unsteady flow structures, such as vortex formation and flow separation. These phenomena are known to be particularly sensitive to mesh resolution and turbulence modelling, and similar levels of discrepancy have been widely reported in experimental–numerical comparisons of draft tube flows. Overall, the validation results demonstrate that the numerical framework provides a reliable representation of turbine performance at BEP, with all observed deviations remaining within established and well-documented limits reported in the hydroturbine CFD literature.
Table 6.
Comparison of experimental and numerical results at BEP conditions.
4.1. Pressure and Velocity Analysis
Figure 6 compares the pressure distribution within the turbine flow domain for the original runner (ORM) and the two modified configurations (RM1 and RM2) under BEP conditions. While the peak pressure levels at the spiral casing inlet differed only marginally among the three configurations, the spatial pressure distribution exhibited notable variations that are more relevant to internal flow behaviour and energy dissipation.
Figure 6.
Comparative analysis of pressure distribution across the suction plane of (ORM), (RM1), and (RM2) at 0.5 s.
Within the runner region, all configurations showed localised high-pressure zones on the pressure side of the blades near the guide vane–runner interface, accompanied by lower-pressure regions toward the runner outlet and beneath the runner cone. Compared with ORM, RM1 and RM2 reduced the extent of pressure accumulation in these regions, with RM2 exhibiting the most homogeneous pressure distribution across the runner surfaces. This increased pressure uniformity indicates a more balanced blade loading and reduced local pressure gradients, which are closely associated with lower wall shear stress and reduced friction-related losses. In the draft tube, ORM displayed an extended low-pressure region that penetrated the cone and elbow sections, a flow feature commonly associated with separation and increased energy dissipation. In contrast, RM1 and RM2 demonstrated improved pressure recovery and smoother pressure contours downstream of the runner, suggesting enhanced flow attachment and reduced separation intensity. These trends indicate that reducing the runner exit height modifies the flow expansion process, leading to improved pressure recovery, enhanced flow stability, and a corresponding reduction in internal mechanical friction losses. The pressure-field behaviour observed in Figure 6 is therefore consistent with the friction torque reductions and efficiency improvements reported for the modified runner configurations.
Figure 7 illustrates the velocity magnitude distribution on the suction plane for the original runner (ORM) and the modified configurations (RM1 and RM2), providing a complementary perspective to the pressure fields presented in Figure 6. In the spiral casing and guide vane regions, all configurations exhibited comparable velocity levels, although RM2 showed slightly higher local acceleration near the guide vane–runner interface and blade leading edges. These local velocity increases were consistent with the upstream pressure gradients and indicated a more confined flow acceleration in the modified geometry. Within the runner, regions of elevated velocity appeared near the blade trailing edges and beneath the runner cone, where pressure reduction promotes flow acceleration and shear development. ORM exhibited the most pronounced and spatially concentrated high-velocity pockets, indicating stronger velocity fluctuations and enhanced shear intensity. In contrast, RM1 and RM2 reduced the extent of these regions and promoted a more uniform velocity distribution across the runner passages, suggesting the mitigation of abrupt pressure gradients and reduced friction-related dissipation. Downstream in the draft tube, ORM developed elongated high-velocity cores extending into the cone and elbow sections, which are indicative of increased shear and energy loss. In comparison, RM1 and RM2 demonstrated smoother velocity recovery and more confined high-speed regions, with RM2 exhibiting the most stable and coherent velocity structure. These results confirm that the uniform exit-height reduction effectively stabilises the flow, suppresses excessive shear, and contributes to the observed reductions in internal mechanical friction losses and improvements in turbine efficiency.
Figure 7.
Velocity magnitude distribution across the suction plane of ORM, RM1, and RM2 at 0.5 s.
Figure 8 illustrates the transient evolution of velocity vectors and contours within the draft tube of the original runner (ORM) at selected time instants under BEP operation. At early times (t = 0.05–0.25 s), elevated velocities were concentrated near the draft-tube inlet and upper cone region, extending into the elbow. The flow was predominantly aligned along the walls, while local recirculation zones formed beneath the runner cone, indicating the onset of unsteady flow behaviour. As time progressed (t = 0.35 s), the high-velocity region became more confined to the upper cone, and the recirculation beneath the runner cone intensified. This was evidenced by denser and more curved velocity vectors, reflecting enhanced vortex activity and increased shear in this region. The elbow section continued to exhibit comparatively lower velocities and more organised flow, suggesting partial flow recovery downstream. At t = 0.5 s, the velocity field maintained a similar overall structure, confirming the persistence of an unsteady flow pattern rather than a transient numerical artefact. The sustained high-velocity core near the draft-tube inlet and the stable recirculation zone beneath the runner cone indicate a quasi-periodic behaviour associated with draft-tube vortical structures. Such unsteady velocity distributions are known to promote energy dissipation and contribute indirectly to increased internal mechanical friction losses through enhanced shear and turbulence intensity. These observations provide a dynamic basis for understanding the flow instability mechanisms that the runner modifications aim to mitigate.
Figure 8.
Velocity vector and contour distributions in the draft tube for the ORM model at different time instants.
Figure 9 presents the transient velocity vector and contour distributions in the draft tube for the RM1 configuration at different time instants. From t = 0.05 s to t = 0.25 s, high-velocity regions near the draft-tube inlet in the upper cone gradually diminished in extent, while forward flow along the walls remained dominant. Recirculation beneath the runner cone persisted but became more organised, indicating partial attenuation of unsteady swirling structures. At t = 0.35 s, elevated velocities remained confined to the upper cone at reduced intensity, and by t = 0.5 s, the high-velocity core weakly extended into the elbow region. The elbow itself maintained a stable, low-velocity flow with well-aligned vectors, suggesting limited backflow and improved flow recovery compared with the original runner.
Figure 9.
Velocity vector and contour distributions in the draft tube for the RM1 model at different time instants.
Figure 10 illustrates the corresponding transient velocity evolution for the RM2 configuration. Across all time instants (t = 0.05–0.35 s), the flow structure closely resembled that of RM1 but exhibited greater spatial coherence. High-velocity regions remained concentrated near the draft-tube inlet in the upper cone, while velocity vectors indicated predominantly forward flow along the walls. Recirculation and backflow beneath the runner cone were further suppressed relative to RM1, as evidenced by weaker swirling intensity and fewer counter-directed vectors. At t = 0.5 s, the flow pattern remained largely unchanged, indicating a stable quasi-periodic behaviour rather than transient growth of instabilities. The elbow section consistently displayed uniform velocity distribution and minimal flow disturbance. Overall, the comparative results in Figure 9 and Figure 10 demonstrate that both RM1 and RM2 improved the draft-tube flow stability relative to the original runner, with RM2 providing the most effective suppression of recirculation and velocity fluctuations. The enhanced temporal stability and reduced shear intensity observed in RM2 were consistent with lower energy dissipation and contributed to the reduction in internal mechanical friction losses reported in subsequent analyses.
Figure 10.
Velocity vector and contour distributions in the draft tube for the RM2 model at different time instants.
Figure 11 compares the absolute pressure distributions on the runner blades for the original runner (ORM) and the modified configurations (RM1 and RM2) under BEP conditions. In all cases, high-pressure regions were concentrated near the blade inlet on the pressure side, while pressure decreased progressively toward the blade outlet and suction side, reflecting the expected pressure–velocity exchange within the runner passage. Although the peak inlet pressures differed only marginally among the three configurations, the spatial distribution of pressure exhibited notable differences. ORM showed steeper pressure gradients along the blade surfaces, particularly toward the outlet region, indicating stronger local acceleration and higher blade loading variability. In contrast, both RM1 and RM2 exhibited a smoother pressure transition from inlet to outlet, with slightly elevated minimum pressure levels near the blade exit. This behaviour suggests a reduction in adverse pressure gradients and improved flow attachment along the blade surfaces. Among the modified configurations, RM2 displayed the most uniform pressure distribution across the runner blades. The attenuation of sharp pressure gradients implies a more balanced blade loading and reduced local shear development near frictional surfaces. Such pressure-field homogenisation is closely associated with lower wall shear stress and reduced friction-induced energy dissipation, providing a physical explanation for the reduced rotational friction torque observed in the modified runners.
Figure 11.
Comparative analysis of absolute pressure distribution across the runner section of ORM, RM1, and RM2.
The pressure distributions in Figure 11 indicate that runner exit-height reduction alters the internal pressure field in a manner that promotes smoother flow development, mitigates localised pressure extremes, and contributes to improved internal flow efficiency within the runner.
4.2. Rotational Friction Torque Analysis
4.2.1. CFD Computations
Using integrals derived from the CFD simulations and defined by Equations (3)–(7), the friction torques acting on the surface components of the blades, hub, shroud, and runner cone were calculated for both the original and modified models. The sum of these friction torques represents the IMFL. The data in Table 7 show that the modified models (RM1 and RM2) had lower friction torques than the original model (ORM), leading to a reduction in IMFL. The RM1 model achieved a 2.76% reduction in this resistance torque, while the RM2 model achieved a 2.83% reduction.
Table 7.
CFD calculations of friction resistance torque on the ORM, RM1, and RM2 models.
Figure 12 presents the temporal evolution of friction resistance torque for the original runner (ORM) and the modified configurations (RM1 and RM2) under BEP conditions. Figure 12a shows the friction torque contribution from the hub–shroud region, while Figure 12b illustrates the total rotational friction torque acting on the runner obtained from the CFD-based integration
Figure 12.
The time evolution of friction resistance torque for two areas: (a) the hub/shroud area and (b) the turbine runner with designs ORM, RM1, and RM2.
In the hub–shroud region (Figure 12a), ORM consistently exhibited the highest friction torque throughout the transient period, decreasing from approximately 4.10 Nm to a quasi-steady value of about 3.86 Nm. In contrast, RM1 and RM2 displayed markedly lower torque levels, stabilising at approximately 3.59 Nm and 3.58 Nm, respectively. Relative to ORM, this corresponded to a reduction of about 7.0% for RM1 and 7.3% for RM2, indicating a substantial decrease in friction losses associated with the modified runner geometries. The total rotational friction torque shown in Figure 12b followed a similar trend. ORM reached a quasi-steady value of approximately 10.00 Nm, whereas RM1 and RM2 stabilised near 9.73 Nm. Compared with ORM, the total friction torque was reduced by approximately 2.76% for RM1 and 2.83% for RM2. Importantly, the consistent reduction observed across both friction-torque components confirms that the geometric modifications produce a robust and physically meaningful decrease in IMFL rather than a transient numerical artefact. The results in Figure 12 demonstrate that exit-height reduction effectively lowered friction-induced torque in the runner, with RM2 providing the most stable and uniformly reduced friction response. These findings provide quantitative support for the friction-loss mitigation mechanism proposed in this study and form the basis for the efficiency improvements discussed in the subsequent sections.
Figure 13 illustrates the wall shear stress distributions on the runner components for the original runner (ORM) and the two modified configurations (RM1 and RM2). Since wall shear stress is the primary source of viscous friction torque, these distributions provide direct insight into the mechanisms governing internal mechanical friction losses within the runner.
Figure 13.
Rotation friction torque on runner section (blades and hub–shroud): (a) ORM; (b) RM1; (c) RM2.
In the ORM case, Figure 13a, elevated wall shear stresses were observed on the blade surfaces, particularly near the leading edges and blade tips, as well as along the hub–shroud region. Peak shear stress reaches approximately 184.62 Pa on the blades and 124.19 Pa on the hub–shroud, reflecting strong near-wall velocity gradients associated with accelerated flow and pronounced blade loading. The non-uniform distribution, especially toward the blade outlet region, indicates localised friction-intensive zones that contribute significantly to rotational friction torque. For the RM1 configuration (Figure 13b), selective exit-height reduction results in a measurable attenuation of wall shear stress on both the blade and hub–shroud surfaces. Maximum blade shear stress decreases to approximately 181.26 Pa, while the hub–shroud region exhibits a slight reduction to about 123.66 Pa. In addition to lower peak values, the shear stress distribution becomes more uniform along the blade span, with reduced concentration at the blade tips. This indicates that selective geometric modification moderates near-wall velocity gradients and weakens local friction hotspots. The RM2 configuration, as shown in Figure 13c, exhibits the most homogeneous wall shear stress distribution among the three cases. Peak blade shear stress further decreases to approximately 178.16 Pa, while the hub–shroud region displays a smoother and more symmetric stress pattern. Although local hub–shroud stresses remain comparable to those of RM1, their spatial extent is reduced, indicating a more evenly distributed flow–surface interaction. The unified exit-height reduction promotes smoother flow development along the blade passage, suppressing sharp shear gradients and minimising friction-intensive regions. The progressive reduction and homogenisation of wall shear stress from ORM to RM1 and RM2 demonstrate that runner exit-height modification effectively mitigates viscous friction losses. The observed decrease in both peak stress magnitude and spatial non-uniformity provides a direct physical explanation for the reduced friction torque and improved efficiency measured in the modified runners.
Despite the demonstrated reductions in frictional resistance torque achieved by the RM1 and RM2 configurations, the proposed runner modifications may also introduce potential limitations. Excessive runner exit-height reduction could increase structural stress at the blade roots and alter cavitation behaviour under off-design conditions. In addition, changes in exit geometry can influence local pressure distributions, potentially affecting cavitation inception and development in regions sensitive to low-pressure fluctuations. These aspects do not negate the observed performance benefits but highlight the need for integrated structural, cavitation, and operational assessments when considering the practical implementation of such design modifications.
4.2.2. Theoretical Verification
Based on the 2D drawing of the Francis-99 runner described in Figure 5, the dimensions used for the calculations were as follows: and . Furthermore, the heights , , and were derived from Table 2. The values of the friction resistance coefficients and Reynolds numbers associated with these four rotating friction interfaces of the Francis-99 turbine were determined using Equations (14) and (15) and are given in Table 8. The calculation of these values can increase our understanding of the forces of resistance encountered at the rotating surfaces of friction and provide essential insights into the forces of friction occurring at Francis turbines.
Table 8.
Friction resistance coefficient for rotational motion.
The torque of friction of every friction surface of the runner, both before and after modification, was determined using the integration model described in Equations (17)–(22). Equation (23) provided the combined value of these losses, referred to as IMFL. The results, as demonstrated in Table 9, showed a reduction of 4.2% on RM1 and 4.5% on RM2 compared to ORM for IMFL. These findings suggest that the value of IMFL is significantly influenced by the geometry of the runner, supporting previous deductions made using CFD-based computational techniques.
Table 9.
The friction resistance torque calculations for each rotating surface.
4.3. Power Calculation Analysis
Figure 14, together with Table 10, summarises the distribution of power losses in the main components of the Francis turbine—namely the runner, draft tube, and distributor—for the original runner (ORM) and the modified configurations (RM1 and RM2). In addition, Table 10 reports the corresponding total power losses and mechanical friction losses calculated using Equation (12).
Figure 14.
Power losses at different sections in the Francis turbine: (a) draft tube, (b) runner, and (c) total losses, for the ORM, RM1, and RM2 over a 0.5 s.
Table 10.
Power loss calculations before and after runner modification, along with the total power loss and mechanical friction losses.
Figure 14a shows the temporal evolution of power losses within the runner. Among the three configurations, ORM exhibited the highest runner power loss, reaching 756.95 W under steady conditions. In contrast, RM1 and RM2 reduced the runner losses to 715.02 W and 706.95 W, corresponding to reductions of 5.54% and 6.61%, respectively. These reductions were consistent with the previously observed decreases in wall shear stress and friction torque, indicating that the runner exit-height modifications mitigated viscous energy dissipation within the rotating domain. The draft tube power losses are presented in Figure 14b. Compared with ORM, which exhibited a draft tube loss of 87.39 W, both modified configurations showed substantially lower losses. RM1 and RM2 reduced the draft tube losses to 62.57 W and 62.29 W, corresponding to decreases of 28.40% and 28.72%, respectively. This improvement reflects enhanced pressure recovery and more stable velocity fields downstream of the runner, as previously evidenced by the velocity and pressure distributions in Figure 6, Figure 7, Figure 8, Figure 9 and Figure 10. In contrast, the power losses in the distributor section remained largely unchanged, as reported in Table 10. Both RM1 and RM2 showed only marginal increases in distributor losses (0.16% and 0.15%, respectively), suggesting that the runner modifications exerted minimal influence on upstream flow structures. Figure 14c presents the total power loss across the turbine. The ORM configuration exhibited the highest total loss of 1612.16 W, whereas RM1 and RM2 reduced the total losses to 1496.43 W and 1374.47 W, corresponding to overall reductions of 7.18% and 14.74%, respectively. The mechanical friction loss component, calculated from the integrated friction torque, followed the same trend. Compared to ORM, mechanical friction losses decreased by 8.20% in RM1 and by a more pronounced 25.54% in RM2.
The combined analysis of Figure 14 and Table 10 demonstrates that runner exit-height modification effectively reduces internal power losses, with RM2 providing the most substantial improvement. The reductions in runner and draft tube losses confirm that geometric optimisation can simultaneously mitigate frictional dissipation and improve downstream flow recovery, leading to enhanced turbine efficiency.
Figure 15, together with Table 11, compares the time-dependent evolution of turbine power output, total input power, and hydraulic efficiency for the original runner (ORM) and the modified configurations (RM1 and RM2) over a 0.5 s simulation period.
Figure 15.
Time-dependent evolution; (a) turbine power, (b) total input power, and (c) hydraulic efficiency for ORM, RM1, and RM2 over 0.5 s.
Table 11.
Performance parameter comparison for the ORM, RM1, and RM2 models.
Figure 15a presents the temporal variation of turbine power output. All configurations exhibited a rapid initial rise followed by stabilisation, indicating the attainment of quasi-steady operating conditions. The ORM stabilised at a power output of 22,533.39 W, whereas RM1 and RM2 achieved slightly higher stabilised outputs of 22,578.50 W and 22,577.32 W, corresponding to increases of 0.20% and 0.19%, respectively. Although modest in magnitude, these gains reflect the cumulative effect of reduced internal losses in the modified runners. The corresponding turbine power input is shown in Figure 15b. Compared with ORM, which required an input power of 24,145.55 W, both modified configurations operated at lower input levels. RM1 reduced the required input power to 24,074.93 W (−0.29%), while RM2 exhibited a more pronounced reduction to 23,951.78 W (−0.80%). These reductions were consistent with the previously identified decreases in frictional and hydraulic losses within the runner and downstream components. Figure 15c illustrates the evolution of hydraulic efficiency over time. All models showed a rapid efficiency increase during the initial transient phase, followed by stabilisation. The modified runners achieved higher steady-state efficiencies than ORM, with RM1 stabilising at 93.78% and RM2 at 94.26%, compared to 93.32% for the original configuration. As summarised in Table 11, this corresponded to efficiency improvements of approximately 0.5% for RM1 and 1.0% for RM2. The combined trends in power output, input power, and efficiency demonstrate that runner exit-height modification enhances turbine performance by simultaneously reducing internal losses and improving energy conversion efficiency, with RM2 delivering the most pronounced performance gains.
5. Conclusions
In this research paper, the role of IMFLs on the performance of Francis-99 turbines was investigated. The original runner model (ORM) was modified with two designs: Selective Exit-Height Reduction (RM1) and Unified Exit-Height Reduction (RM2), to reduce the contact surface of the turbine blades with the surrounding fluid while maintaining the total number of blades at the turbine outlets as in the original design. A combined system utilising CFD techniques and theory was employed to assess the impact of each model on mitigating these losses and enhancing turbine efficiency. The significant findings of this study are summarised below:
The internal flow performances of the two modified runners were improved due to diminished turbulence and flow separation, minimised adverse pressure gradients, and optimised equal pressure distribution. Computational fluid dynamics analysis revealed a considerable decrease in wall shear stresses on the surface of the blade, hub, and shroud portions of the modified model compared to those in the original runner model (ORM), resulting in a diminished friction torque.
The geometrical modification efficiently reduced the amount of energy loss, as proven by the analysis of energy loss. There was an improvement of 7.18% power loss with RM1; however, there was a greater improvement of 14.74% using RM2. The torque introduced by frictional forces for both improved models was reduced compared to that of the original model. More precisely, RM1 reduced IMFL by about 2.76%, while RM2 showed the greatest improvement with a decrease of 2.83%.
Among all configurations, RM2 exhibited the best performance, attaining a maximum power output of 22,577.32 W and a turbine efficiency of 94.26%, corresponding to a 1% absolute improvement over ORM. The results confirm that runner exit-height modification is an efficient and practical approach to improving the performance of Francis turbines. The proposed CFD and theoretical methods provide a robust framework for analysing and quantifying IMFLs, as well as guiding future optimisation of hydraulic machinery.
Future work should extend the present methodology beyond best efficiency point conditions to include off-design operation, cavitation behaviour, and transient load variations, where internal mechanical friction losses may be more pronounced. Prototype-scale experimental validation is recommended to assess the scalability of the numerical results. In addition, future optimisation studies should adopt a multi-objective framework that integrates hydraulic performance with structural and cavitation constraints to support the practical application of the proposed runner design strategies.
Author Contributions
Conceptualization, O.M.M.A. and Y.Z.; methodology, O.M.M.A., Y.Z. and J.D.; software, O.M.M.A. and A.A.M.A.; validation, O.M.M.A., Y.Z. and J.D.; formal analysis, O.M.M.A.; investigation, O.M.M.A., Y.Z. and J.D.; resources, Y.Z.; data curation, Y.Z.; writing—original draft preparation, O.M.M.A.; writing—review and editing, A.A.M.A., H.B. and A.A.A.O.; visualization, O.M.M.A., Y.Z., J.D. and A.A.A.O.; supervision, Y.Z. and J.D.; project administration, Y.Z.; funding acquisition, Y.Z. All authors have read and agreed to the published version of the manuscript.
Funding
This work was financially supported by the National Natural Science Foundation of China (NSFC) Projects (Grant Nos. 52479084, 52309113) and the Yunnan Fundamental Research Projects (Grant No. 202501AT070316). We used the test case provided by NTNU, the Norwegian University of Science and Technology, under the Francis-99 workshop series.
Data Availability Statement
Dataset available on request from the authors.
Acknowledgments
The authors sincerely thank the Francis-99 workshop organizers at NTNU and LTU for providing the validated geometry and benchmark data that supported this study. Financial support from the National Natural Science Foundation of China and the Yunnan Fundamental Research Projects is gratefully acknowledged. The authors also appreciate the technical support from Kunming University of Science and Technology.
Conflicts of Interest
The authors declare that they have no conflicts of interest.
Abbreviations
The abbreviations and terms used in this manuscript are as follows:
| Abbreviation | Definition |
| IMFL | Internal mechanical friction loss |
| NTNU | Norwegian university of science and technology |
| CFD | Computational fluid dynamics |
| BEP | Best efficiency point |
| SMM | Sliding mesh model |
| SST | Shear stress transfer |
| RANS | Reynolds-averaged Navier–Stokes |
| Re | Reynolds number |
| ORM | Original runner model |
| RM 1 | Runner model 1 |
| RM 1 | Runner model 2 |
Nomenclature
| Symbol | Definition | Unit |
| Volumetric loss coefficient | – | |
| Hydraulic loss coefficient | – | |
| Turbine output power | kW | |
| Theoretical water power | kW | |
| Hydraulic loss | kW | |
| Volumetric loss | kW | |
| Mechanical loss | kW | |
| Impact loss | kW | |
| Total (static) pressure at inlet | Pa | |
| Total (static) pressure at outlet | Pa | |
| Flow velocity at inlet | m·s−1 | |
| Flow velocity at outlet | m·s−1 | |
| Fluid density | kg·m−3 | |
| Specific weight of water | kN·m−3 | |
| Flow rate | m3·s−1 | |
| Gravitational acceleration | m s−2 | |
| Hydraulic head | m | |
| Turbine efficiency | – | |
| Generator torque | N·m | |
| Wall shear stress | N·m−2 | |
| Rotational speed of runner | rad·s−1 | |
| Radial distance to axis of rotation | m | |
| Friction coefficient | – | |
| Height of wetted area | m | |
| Surface curvature | rad | |
| Undetermined empirical constants | – | |
| Friction resistance torque | N·m | |
| Infinitesimal surface area | m2 | |
| Wetted surface area | m2 | |
| Dynamic viscosity | N·s·m−2 |
References
- Muhirwa, A.; Cai, W.-H.; Su, W.-T.; Liu, Q.; Binama, M.; Li, B.; Wu, J. A review on remedial attempts to counteract the power generation compromise from draft tubes of hydropower plants. Renew. Energy 2020, 150, 743–764. [Google Scholar] [CrossRef] [Scilit]
- Trivedi, C.; Cervantes, M.J.; Dahlhaug, O.G.; Gandhi, B.K. Experimental Investigation of a High Head Francis Turbine During Spin-No-Load Operation. J. Fluids Eng. 2015, 137, 061106. [Google Scholar] [CrossRef] [Scilit]
- Ji, Y.; Song, H.; Xue, Z.; Li, Z.; Tong, M.; Li, H. A Review of the Efficiency Improvement of Hydraulic Turbines in Energy Recovery. Processes 2023, 11, 1815. [Google Scholar] [CrossRef] [Scilit]
- Mössinger, P.; Jung, A. Transient two-phase CFD simulation of overload operating conditions and load rejection in a prototype sized Francis turbine. IOP Conf. Ser. Earth Environ. Sci. 2016, 49, 092003. [Google Scholar] [CrossRef] [Scilit]
- Kumar, S.; Gandhi, B.K. Effect of water jet area on mitigation of vortex rope in a Francis turbine. Phys. Fluids 2023, 35, 105146. [Google Scholar] [CrossRef] [Scilit]
- Joy, J.; Raisee, M.; Cervantes, M.J. Experimental investigation of an adjustable guide vane system in a Francis turbine draft tube at part load operation. Renew. Energy 2023, 210, 737–750. [Google Scholar] [CrossRef] [Scilit]
- Trivedi, C.; Cervantes, M.J.; Gandhi, B.K.; Dahlhaug, O.G. Experimental and Numerical Studies for a High Head Francis Turbine at Several Operating Points. J. Fluids Eng. 2013, 135, 111102. [Google Scholar] [CrossRef] [Scilit]
- Mössinger, P.; Jester-Zürker, R.; Jung, A. Francis-99: Transient CFD simulation of load changes and turbine shutdown in a model sized high-head Francis turbine. J. Phys. Conf. Ser. 2017, 782, 012001. [Google Scholar] [CrossRef] [Scilit]
- Trivedi, C.; Cervantes, M.J.; Dahlhaug, O.G. Experimental and Numerical Studies of a High-Head Francis Turbine: A Review of the Francis-99 Test Case. Energies 2016, 9, 74. [Google Scholar] [CrossRef] [Scilit]
- Atkins, M.D.; Kienhöfer, F.W.; Lu, T.J.; Chang, S.-M.; Kim, T. The Role of Secondary Flows and Separation in Convective Heat Transfer in a Rotating Radial Vane Brake Disk. J. Heat Transf. 2021, 143, 081801. [Google Scholar] [CrossRef] [Scilit]
- Lei, L.; Li, F.; Xu, B.; Egusquiza, M.; Luo, X.; Zhang, J.; Egusquiza, E.; Chen, D.; Jiang, W.; Patelli, E. Time-frequency domain characteristics analysis of a hydro-turbine governor system considering vortex rope excitation. Renew. Energy 2022, 183, 172–187. [Google Scholar] [CrossRef] [Scilit]
- Zeng, H.; Li, Z.; Li, D.; Chen, H.; Li, Z. Vortex Distribution and Energy Loss in S-Shaped Region of Pump Turbine. Front. Energy Res. 2022, 10, 904202. [Google Scholar] [CrossRef] [Scilit]
- Puga, D.; Geng, C.; Wang, Z.; Luo, X. Cavitating vortex rope in a diffuser at different operation conditions. Phys. Fluids 2025, 37, 015220. [Google Scholar] [CrossRef] [Scilit]
- Sun, L.; Wen, M.; Ding, X.; Wang, Z.; Guo, P. Numerical assessment of hydrodynamic behavior and energy dissipation during high-head Francis turbine shutdown. Phys. Fluids 2024, 36, 124131. [Google Scholar] [CrossRef] [Scilit]
- Casartelli, E.; Mangani, L.; Ryan, O.; Del Rio, A. Performance prediction of the high head Francis-99 turbine for steady operation points. J. Phys. Conf. Ser. 2017, 782, 012007. [Google Scholar] [CrossRef] [Scilit]
- Kim, S.-J.; Suh, J.-W.; Yang, H.-M.; Park, J.; Kim, J.-H. Internal flow phenomena of a Pump–Turbine model in turbine mode with different Thoma numbers. Renew. Energy 2022, 184, 510–525. [Google Scholar] [CrossRef] [Scilit]
- Trivedi, C.; Cervantes, M.J.; Gandhi, B.K. Investigation of a High Head Francis Turbine at Runaway Operating Conditions. Energies 2016, 9, 149. [Google Scholar] [CrossRef] [Scilit]
- Wang, L.; Cui, J.; Shu, L.; Jiang, D.; Xiang, C.; Li, L.; Zhou, P. Research on the Vortex Rope Control Techniques in Draft Tube of Francis Turbines. Energies 2022, 15, 9280. [Google Scholar] [CrossRef] [Scilit]
- Mao, X.; Zhong, P.; Li, Z.; Liu, Z.; Hu, J.; Yan, J. Development and application of modified partially averaged Navier Stokes in the internal flow field of a Francis turbine. Phys. Fluids 2025, 37, 025107. [Google Scholar] [CrossRef] [Scilit]
- Sun, L.; Liu, L.; Xu, Z.; Guo, P. Numerical investigation of no-load startup in a high-head Francis turbine: Insights into flow instabilities and energy dissipation. Phys. Fluids 2024, 36, 035142. [Google Scholar] [CrossRef] [Scilit]
- Favrel, A.; Lee, N.-J.; Irie, T.; Miyagawa, K. Design of Experiments Applied to Francis Turbine Draft Tube to Minimize Pressure Pulsations and Energy Losses in Off-Design Conditions. Energies 2021, 14, 3894. [Google Scholar] [CrossRef] [Scilit]
- Bannikov, D.V.; Yesipov, D.V.; Cherny, S.G.; Chirkov, D.V. Optimization design of hydroturbine rotors according to the efficiency-strength criteria. Thermophys. Aeromechanics 2010, 17, 613–620. [Google Scholar] [CrossRef] [Scilit]
- Chen, J.; Zheng, Y.; Zhang, L.; He, G.; Zou, Y.; Xiao, Z. Optimization of geometric parameters of hydraulic turbine runner in turbine mode based on the orthogonal test method and CFD. Energy Rep. 2022, 8, 14476–14487. [Google Scholar] [CrossRef] [Scilit]
- Thapa, B.S.; Thapa, B.; Eltvik, M.; Gjosater, K.; Dahlhaug, O.G. Optimizing runner blade profile of Francis turbine to minimize sediment erosion. IOP Conf. Ser. Earth Environ. Sci. 2012, 15, 032052. [Google Scholar] [CrossRef] [Scilit]
- Shrestha, K.P.; Chitrakar, S.; Thapa, B.; Dahlhaug, O.G. Performance Comparison of Optimized Designs of Francis Turbines Exposed to Sediment Erosion in various Operating Conditions. J. Phys. Conf. Ser. 2018, 1042, 012001. [Google Scholar] [CrossRef] [Scilit]
- Lu, J.; Wang, J.; Li, W.; Zhang, T.; Lu, P.; Wu, J.; Gao, N. A brief analysis on refined calculation method for hydraulic turbine efficiency. Huadian Technol. 2016, 38, 63–65. (In Chinese) [Google Scholar] [CrossRef]
- Tran, C.T.; Long, X.-P.; Ji, B.; Liu, C. Prediction of the precessing vortex core in the Francis-99 draft tube under off-design conditions by using Liutex/Rortex method. J. Hydrodyn. 2020, 32, 623–628. [Google Scholar] [CrossRef] [Scilit]
- Cuong, P.; Tran, C.T. Application of Liutex and Entropy Production to Analyze the Influence of Vortex Rope in the Francis-99 Turbine Draft Tube. Teh. Vjesn. 2022, 29, 1177–1183. [Google Scholar] [CrossRef] [Scilit]
- Zhou, X.; Shi, C.; Miyagawa, K.; Wu, H.; Yu, J.; Ma, Z. Investigation of Pressure Fluctuation and Pulsating Hydraulic Axial Thrust in Francis Turbines. Energies 2020, 13, 1734. [Google Scholar] [CrossRef] [Scilit]
- Joy, J.; Raisee, M.; Cervantes, M.J. Hydraulic Performance of a Francis Turbine with a Variable Draft Tube Guide Vane System to Mitigate Pressure Pulsations. Energies 2022, 15, 6542. [Google Scholar] [CrossRef] [Scilit]
- Yu, A.; Tang, Y.; Tang, Q.; Cai, J.; Zhao, L.; Ge, X. Energy analysis of Francis turbine for various mass flow rate conditions based on entropy production theory. Renew. Energy 2022, 183, 447–458. [Google Scholar] [CrossRef] [Scilit]
- Minakov, A.; Sentyabov, A.; Platonov, D. Numerical investigation of flow structure and pressure pulsation in the Francis-99 turbine during startup. J. Phys. Conf. Ser. 2017, 782, 012004. [Google Scholar] [CrossRef] [Scilit]
- Kong, D.; Guo, Z.; Yan, Z. Prototype efficiency test of hydro-generating unit at Xiaolangdi Hydropower Station. Yellow River 2011, 33, 109–111. (In Chinese) [Google Scholar] [CrossRef]
- Shen, Z. Test principle and method discussion of water turbine efficiency. Equip. Manuf. Technol. 2009, 5, 42–43+46. (In Chinese) [Google Scholar] [CrossRef]
- Zhang, Q.; Yang, B.; Liu, X.; Rong, J. Energy characteristics test of the turbine at Longshou Second Stage (Xiliushui) Hydropower Station. Power Syst. Clean Energy 2007, 23, 54–56. (In Chinese). Available online: https://wap.cnki.net/touch/web/Journal/Article/SXFD200701016.html (accessed on 23 January 2026).
- Zhao, Y.; Dong, K.; Dang, Y.; Zhang, L.; Wang, P.; He, J. Energy characteristics acceptance test and benefit analysis after turbine capacity expansion and reconstruction. Hydropower Stn. Electromechanical Technol. 2005, 28, 4. (In Chinese) [Google Scholar] [CrossRef]
- Zhuoma, Q. Analysis of Energy Loss in Hydraulic Turbines and Measures to Reduce Energy Loss. Tibet. Sci. Technol. 2013, 2. Available online: https://kns.cnki.net/kcms2/article/abstract?v=adNygMj_jVBJMEY3XarzlVgzS6yyjWsrquRdnDHvd1svOlIpTJKKOhN7m_rEfcy0HrIyXuGOjB5nF2q2UpUyXjLqUvJzJCC6yF8R9_OCYeZ99Ry0qScsLOcSPy3mQnpPjkC-ffLUs-wQkk6ChOP05TFtgxHyuM7kAit8K7fymTlRUTT2gZL1zg==&uniplatform=NZKPT&language=CHS (accessed on 23 January 2026).
- Xie, H. Operation and Maintenance of Small and Medium-Sized Hydro-Generator Sets; China Electric Power Press: Beijing, China, 2007; Available online: https://libopac.gdut.edu.cn/bookinfo.aspx?ctrlno=381036 (accessed on 23 January 2026).
- Zheng, Y.; Ju, X.; Cheng, Y. Hydraulic Turbines; China Water Resources and Hydropower Press: Beijing, China, 2007; Available online: https://vufind.library.sh.cn/Record/4fc42292-b779-4330-8f3a-201496a112de (accessed on 23 January 2026).
- Zeng, Y.; Guo, Y.; Zhang, L.; Xu, T.; Dong, H. Torque model of hydro turbine with inner energy loss characteristics. Sci. China Technol. Sci. 2010, 53, 2826–2832. [Google Scholar] [CrossRef] [Scilit]
- Qian, J.; Zeng, Y.; Guo, Y.; Zhang, L. Reconstruction of the complete characteristics of the hydro turbine based on inner energy loss. Nonlinear Dyn. 2016, 86, 963–974. [Google Scholar] [CrossRef] [Scilit]
- Zeng, Y.; Zhang, L.X.; Guo, J.P.; Guo, Y.K.; Pan, Q.L.; Qian, J. Efficiency limit factor analysis for the Francis-99 hydraulic turbine. J. Phys. Conf. Ser. 2017, 782, 012008. [Google Scholar] [CrossRef] [Scilit]
- Zhang, T.; He, G.; Guang, W.; Lu, J.; Song, X.; Zhu, D.; Zhengwei, W. Investigation of the Internal Flow in a Francis Turbine for Comparing the Flow Noise of Different Operation Conditions. Water 2023, 15, 3461. [Google Scholar] [CrossRef] [Scilit]
- Du, J.; Ge, Z.; Wu, H.; Shi, X.; Yuan, F.; Yu, W.; Wang, D.; Yang, X. Study on the effects of runner geometric parameters on the performance of micro Francis turbines used in water supply system of high-rise buildings. Energy 2022, 256, 124616. [Google Scholar] [CrossRef] [Scilit]
- Huang, W.; Yang, K.; Guo, X.; Ma, J.; Wang, J.; Li, J. Prediction Method for the Complete Characteristic Curves of a Francis Pump-Turbine. Water 2018, 10, 205. [Google Scholar] [CrossRef] [Scilit]
- Feng, J.; Luo, X.; Zhu, G.; Wu, G. Investigation on disk friction loss and leakage effect on performance in a Francis model turbine. Adv. Mech. Eng. 2017, 9, 1687814017723792. [Google Scholar] [CrossRef] [Scilit]
- NTNU-LTU. Francis99 Workshop Series. Available online: https://www.ntnu.edu/nvks/f99-test-case2 (accessed on 23 January 2026).
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.