Uplift Behavior of Group-Pile Anchorage Systems for Offshore Large-Span Cable-Supported Photovoltaic Structures: Effects of Interface Friction, Cable Prestress, and Local Stiffness Degradation

,
,
,
,
and
1
PowerChina Huadong Engineering Corporation Limited, Hangzhou 311122, China
2
Zijin School of Geology and Mining, Fuzhou University, Fuzhou 350108, China
3
Fujian-Taiwan Science and Technology Cooperation Base of Fujian Province on Intelligent Geo-Environmental Engineering, Fuzhou 350116, China
4
College of Civil Engineering and Architecture, Jiaxing University, Jiaxing 314001, China
This article belongs to the Section Ocean Engineering

Abstract

Existing pile-foundation codes generally specify ultimate uplift-capacity and deformation checks, but they do not explicitly address the coupled redistribution of uplift among main and anchorage piles caused by prestressed cables and local stiffness degradation in large-span cable-supported offshore PV structures. To investigate the uplift behavior of group-pile anchorage systems for offshore large-span cable-supported photovoltaic structures under wind suction loading, a three-dimensional nonlinear finite element model was developed, incorporating Mohr–Coulomb soil plasticity, surface-to-surface hard contact with penalty friction, beam elements for the upper structure and cables, and cable prestress applied by the temperature-reduction method. The effects of pile–soil interface friction, initial cable prestress, and local stiffness degradation of the supported structure on the uplift response were investigated. The results indicate that the main pile group exhibits a deformation pattern characterized by compression on both sides and tension in the middle, with piles B2, C2, and D2 acting as the primary uplift-resistant piles. The uplift displacements of piles B2, C2, and four windward anchorage piles exceed 100 mm. Increasing the pile–soil interface friction coefficients of piles B2 and C2 improves their uplift resistance and induces load redistribution among the piles. Increasing the initial cable prestress enhances the tensile forces in the leeward anchorage piles. Local stiffness degradation has a weak effect on piles B2 and D2 but induces pronounced load redistribution to pile C2 and the leeward anchorage piles. These findings quantify the coupled mechanisms by which interface friction, cable prestress, and local stiffness degradation control three-dimensional uplift redistribution and the sequence of critical pile mobilization in a cable-supported pile–soil system. The results provide a reference for pile layout and capacity design, prestress selection, and service-safety assessment of offshore cable-supported PV structures.

1. Introduction

As a promising form of marine renewable energy, offshore photovoltaic (PV) systems offer significant advantages, including no occupation of terrestrial land resources and the potential for integrated utilization of marine spaces. With the gradual expansion of PV projects from conventional land-based areas to complex environments such as tidal flats and nearshore waters, traditional rigid PV-supported structures face challenges associated with a large number of pile foundations, high construction and maintenance costs, and limited spanning capability, which restrict their application under large-span and complex site conditions. Large-span cable-supported PV structures employ prestressed cables to replace part of the rigid structural components, providing advantages such as large spanning capability, lightweight characteristics, reduced intermediate supports, and strong adaptability to spatial conditions. However, their high flexibility, low damping, and pronounced geometric nonlinearities make wind loading a critical factor governing structural safety. Meanwhile, pile foundations serve as an essential component for transferring loads from the upper structure and maintaining overall structural stability, and their uplift resistance directly affects the safe operation of offshore PV support systems. Previous studies have demonstrated that wind pressure on PV modules is significantly affected by wind direction angle, module inclination angle, spacing between modules, and array edge effects, resulting in a non-uniform distribution along the PV array [1,2,3]. For flexible cable-supported PV systems, wind speed, initial cable prestress, and structural stiffness can further influence structural deformation, dynamic response, and stability performance [4,5].
The anchorage system of offshore large-span cable-supported photovoltaic structures consists of the upper supported structure, prestressed cables, main pile group, anchorage piles, and seabed soil, forming a typical multi-component coupled statically indeterminate system. After wind suction loads are transferred through the upper cable–beam system to the pile foundations, piles at different locations may be subjected to tensile or compressive forces, accompanied by pronounced load redistribution within the pile group. Therefore, identifying the locations of critical uplift piles and clarifying the distribution of pile compression as well as the uplift deformation characteristics are essential for ensuring the overall stability and service safety of the structure.
The uplift response of pile foundations is governed not only by external loading but also by pile–soil interface conditions, initial cable prestress, and the stiffness of the upper structure. Shaft resistance provides the primary mechanism by which tension piles resist uplift loads, and its mobilization is affected by soil properties, interface characteristics, loading conditions, and pile-group interaction [6,7,8]. Previous studies have shown that pile spacing, group configuration, and pile–soil interaction mechanisms can significantly influence the load-bearing performance and load transfer behavior of tension pile groups [9,10,11]. In addition, the initial cable prestress determines the initial configuration and overall stiffness of the structural system, and variations in prestress can alter the load distribution between the main piles and anchorage piles. Corrosion and connection damage in marine environments may also cause stiffness degradation of upper structural components, thereby modifying the structural load-transfer path and the force state of the pile foundations [12,13]. Therefore, evaluating the effects of these key factors on pile uplift performance from the perspective of the overall coupled system comprising the upper supported structure, prestressed cables, group-pile foundation, and seabed soil is of considerable significance for optimizing design parameters and assessing structural safety during service.
Existing studies on the mechanical behavior of photovoltaic (PV) support systems have mainly focused on two aspects: the wind-induced response of the upper flexible structure and the uplift performance of the lower pile foundation. Liu et al. [14], Xu et al. [15], and Li et al. [5] investigated the wind response characteristics of flexible PV-supported structures through wind tunnel tests, wind-induced vibration analyses, and studies of instability mechanisms, respectively. Liu et al. [16], Zhu et al. [17], and Wu et al. [18] further examined the effects of module parameters, initial cable prestress, and structural stiffness on the response of flexible PV systems. For offshore PV structures, Choi et al. [19] investigated the influence of wind–wave loading directions on the response of floating PV systems. Regarding pile foundations, Das et al. [20], Madhav [21], and Shelke et al. [22] studied the effects of pile-group configuration, pile interaction, and soil arching on uplift performance, while Reddy et al. [23], Al-Khazaali et al. [24], and Ashour et al. [25] further investigated the load-transfer behavior of tension piles under different soil and loading conditions.
Recent studies have further advanced the wind-resistance analysis of large-span flexible and cable-supported PV structures. Zhou et al. [26] experimentally investigated the wind loads and wind-induced responses of a large-span flexible PV support structure. Qin et al. [27] compared rigid-body and aeroelastic wind-tunnel models and clarified the aeroelastic effect on the wind-induced vibration of large-span flexible PV structures. Zhou et al. [28] experimentally studied the wind-induced response of a 45 m span double-layer cable-supported PV structure with arrays, while Li et al. [29] analyzed the extreme wind-induced response and displacement-based gust response factors of a two-parallel-cable-truss PV system. In addition, Tong et al. [30] proposed a nonlinear multi-objective equivalent static wind-load method for cable-supported PV arrays. These studies have significantly improved the understanding of wind loads, aerodynamic damping, equivalent static loads, and displacement-based response control of large-span cable-supported PV structures. However, their main focus remains on the upper structural system; the wind-induced uplift load transferred to pile-group anchorage systems and the associated load redistribution among main piles and anchorage piles are still insufficiently addressed.
Although previous studies have advanced the understanding of wind-induced responses of flexible PV structures and the uplift capacity of pile foundations, two site-specific factors of offshore large-span cable-supported PV systems remain insufficiently addressed. First, the marine environment is highly corrosive, and long-term corrosion and connection damage can degrade the local stiffness of the upper supported structure, thereby altering the load-transfer path from the cable-beam system to the pile foundation. Second, because the cable-supported structure has a large span, the main piles and anchorage piles are distributed over a wide area, where seabed sediments and geotechnical parameters may vary spatially. Such variability makes the pile–soil interface friction non-uniform and introduces considerable uncertainty into the uplift resistance of individual piles. More importantly, the initial cable prestress controls the initial internal-force state and overall stiffness of the cable-supported system and can further redistribute vertical loads between the main pile group and the anchorage piles. However, the combined effects of initial cable prestress, non-uniform pile–soil interface friction, and local stiffness degradation of the upper supported structure on the uplift behavior of group-pile anchorage systems have not been systematically clarified. This gap restricts the safe and economical design of offshore large-span cable-supported PV support systems, especially under typhoon-induced wind suction.
To address this gap, a three-dimensional nonlinear finite element model of an offshore large-span cable-supported PV support system is established, including the upper supported structure, prestressed cables, main pile group, anchorage piles, and layered seabed soil. Pile–soil interaction is simulated using surface-to-surface frictional contact, and the initial cable prestress is applied by the temperature-reduction method. On the basis of a reference extreme wind-suction condition, three key parameters are varied to address three questions: (i) how do local pile–soil interface conditions affect the uplift resistance and load sharing of the critical piles, with the interface friction coefficients of piles B2 and C2 increased from 0.25 to 0.30 and 0.35; (ii) how does the initial cable prestress control load sharing between the main piles and anchorage piles, with low, medium, and high prestress levels considered; and (iii) how does local stiffness degradation of the upper supported structure alter the load-transfer path and force demand at critical piles, with the stiffness reduced to 0.6E and 0.4E to represent corrosion- and connection-damage-induced degradation in the marine environment. The pile-head axial forces, uplift displacements, critical uplift pile locations, and load redistribution within the pile group are then analyzed. The objective is to reveal the uplift behavior of the group-pile anchorage system and to provide a basis for pile foundation design, cable prestress determination, and service safety assessment of offshore large-span cable-supported PV structures.

2. Finite Element Modeling and Validation

2.1. Model Description and Material Parameters

This study focuses on the group-pile anchorage system of an offshore large-span cable-supported photovoltaic structure and establishes a three-dimensional finite element model incorporating the upper supported structure, prestressed cables, main pile group, anchorage piles, and layered seabed soil, as shown in Figure 1. The structure has a single span of 17.953 m in the longitudinal direction, with four spans in total, and a single span of 5.0 m in the transverse direction, with two spans in total. The main pile group is arranged in five rows along the longitudinal direction and three rows along the transverse direction, giving a total of 15 piles. PHC-600-130-C prestressed high-strength concrete tubular piles are adopted to primarily resist the vertical loads, horizontal loads, and overturning effects transmitted from the upper supported structure. Four winged steel-pipe anchorage piles are arranged on each side of the structure, giving a total of eight anchorage piles. These anchorage piles are connected to the upper supported structure through prestressed cables and mainly contribute to overturning resistance and uplift resistance. The principal load-bearing members of the upper structure are high-strength, low-relaxation prestressing steel strands, which, together with the upper supported structure, prestressed cables, main pile group, and anchorage piles on both sides, form a spatial structural system that works collaboratively under loading. The other main parameters are listed in Table 1.
Figure 1. Finite element model of the group-pile anchorage system for the offshore large-span cable-supported photovoltaic structure.
Table 1. Main parameters of the group-pile foundation for the offshore large-span cable-supported photovoltaic structure.
To account for the influence of pile–soil interaction on the structural response, a three-dimensional soil model was established, in which the soil stress–strain behavior was described using an elastoplastic Mohr–Coulomb constitutive model, with the corresponding mechanical parameters listed in Table 2. The soil, as well as the portions of the main piles and anchorage piles below the mudline, was modeled using solid elements, while the portions of the main pile group above the mudline were simulated using B31 beam elements. The main piles were assigned a density of 2500 kg·m−3, an elastic modulus of 38 GPa, and a Poisson’s ratio of 0.2. The anchorage piles were modeled as linear elastic steel, with a density of 7850 kg·m−3, an elastic modulus of 206 Gpa, and a Poisson’s ratio of 0.3. The cable components were modeled using beam elements, with an elastic modulus of 195 Gpa, a Poisson’s ratio of 0.3, and a coefficient of thermal expansion of 1.17 × 10−5 °C−1. Surface-to-surface contact was adopted between the piles and surrounding soil to simulate the nonlinear pile–soil interaction. “Hard contact” was specified in the normal direction, allowing separation at the pile–soil interface under tension, while a penalty friction formulation was employed in the tangential direction. All translational degrees of freedom were constrained at the bottom boundary of the soil domain, whereas the normal displacement was restrained along the lateral boundaries. A sufficient distance was maintained between the soil boundaries and the pile group to minimize the influence of artificial boundaries on the calculated pile–soil interaction. Before applying the external loads, geostatic equilibrium was established to generate a reasonable initial stress field in the layered seabed soil under self-weight, and the initial prestress in the cables was introduced using a temperature-reduction method.
Table 2. Typical soil parameters.
Wind suction is the primary external load governing the vertical deformation of large-span cable-supported photovoltaic structures and the uplift response of pile groups. To investigate the unfavorable uplift response of the structure under typhoon-resistant design conditions, an extreme wind suction condition corresponding to a Level 14 typhoon, with a design wind speed of approximately 41 m/s, was considered. The characteristic wind load acting normal to the surface of the photovoltaic modules was calculated using the following equations:
F wind   =   w k A
w k   =   β z μ s μ z w 0
where Fwind denotes the wind load acting on the upper structure; wk is the characteristic wind pressure on the surface of the photovoltaic modules; A is the wind-exposed area of the upper structure; βz is the wind vibration coefficient at height z, taken as 1.2; μs is the shape coefficient of the photovoltaic modules and supported structure, taken as −0.95; μz is the wind pressure height coefficient, taken as 1.416; and w0 is the basic wind pressure. Substituting the above parameters into Equation (1) gives:
w k   =   1.2 × ( − 0.95 ) × 1.416 × 1.04   =   − 1.679   kN / m 2
where the negative sign indicates that the wind load acts away from the surface of the photovoltaic modules, corresponding to wind suction. Since the photovoltaic modules were not explicitly modeled in the finite element model, the wind suction acting on the module surfaces was converted, according to the principle of load equivalence, into equivalent line loads applied to the upper cable members. These loads were imposed in the actual wind-suction direction to simulate the transfer of wind loads through the upper cable system to the main pile group and the anchorage piles on both sides.

2.2. Finite Element Solution Procedure and Contact Formulation

Based on the above discretized model, the nonlinear equilibrium equations of the system were solved using an incremental–iterative procedure, with the effects of large structural deformation, changes in pile–soil contact conditions, and material nonlinearity taken into account. Within each load increment, the global equilibrium equation of the discretized system can be expressed as:
R ( u )   =   F ext   −   F int u   =   0
where R is the residual force vector, Fext is the global external load vector, and Fint is the global internal force vector associated with the nodal displacement vector u, including both the internal forces of the structural components and the equivalent nodal forces arising from contact interactions. The Newton–Raphson method was employed to iteratively linearize Equation (3), and the incremental equation at the ith iteration can be written as:
K T ( i ) Δ u ( i )   =   R ( i )
where KT is the tangent stiffness matrix of the system at the current configuration, consisting of the material stiffness, geometric stiffness, and contact stiffness; Δu is the nodal displacement correction vector at the current iteration; and R is the corresponding residual force vector. Once the force residual and displacement correction satisfy the prescribed convergence criteria, the analysis proceeds to the next load increment. This procedure enables the variation in system stiffness caused by structural deformation and changes in contact conditions to be properly captured.
(1) Beam Element Analysis Theory
The portions of the main piles above the mudline and the cable members were modeled using three-dimensional two-node linear beam elements. Each node of the element has three translational degrees of freedom and three rotational degrees of freedom, enabling the axial, bending, shear, and torsional responses of the members to be represented. For large-displacement problems, the beam element formulation updates the configuration and performs consistent linearization based on the current deformed state. In the incremental linearized form, the relationship between the generalized strain and nodal displacement of a beam element can be expressed as
ε b   =   B b d e
where εb is the generalized strain vector of the beam element, including the axial strain, shear strains in the two local directions, bending curvatures, and twist rate; Bb is the strain–displacement matrix of the beam element; and de is the element nodal displacement vector. Within the linear elastic range, the section stress resultants are related to the generalized strains by
S b   =   D b ε b
where Db is the generalized sectional stiffness matrix and Sb is the vector of section stress resultants, which can be written as
S b   =   N V 2 V 3 T M 2 M 3 T
where N is the axial force; and V3 are the shear forces in the local 2- and 3-directions, respectively; T is the torsional moment; and M2 and M3 are the bending moments about the local 2- and 3-axes, respectively. The section resultants are obtained by integrating the sectional stresses over the cross-sectional area. The axial force is given by
N   =   ∫ A σ 11 d A
where A is the beam cross-sectional area and σ11 is the normal stress in the local 1-direction of the beam element. For the vertically arranged portions of the main piles above the mudline considered in this study, the local 1-direction of the beam elements coincides with the longitudinal axis of the pile. Therefore, the Abaqus section-force output variable SF1 can be used to characterize the axial force of the pile. In the post-processing procedure, the SF1 value of the beam element immediately below the pile head was extracted as the vertical axial force at the pile head, with tension defined as positive and compression as negative.
(2) Pile–Soil Normal Contact Model
During pile uplift, the pile and surrounding soil may undergo contact, separation, and recontact, while the contact area and contact pressure continuously evolve with structural deformation, constituting a typical contact nonlinearity problem. The contact traction acting on the pile–soil interface consists of the normal contact pressure and tangential frictional traction and can be expressed as
t c   =   p n n c   +   τ t
where pn is the normal contact pressure, defined as positive in compression; nc is the outward unit normal vector of the contact surface; and τt is the tangential contact traction vector. After discretization of the contact surface, the contact traction is converted into an equivalent nodal contact force:
F c   =   ∫ Γ c N T t c d Γ
where Γc denotes the pile–soil contact surface, Nc is the interpolation function matrix of the contact surface, and Fc is the equivalent nodal force generated by the contact interaction and included in the global internal force vector. In this study, “hard contact” was adopted in the normal direction, allowing separation between the pile and soil during uplift. If the normal gap of the designated contact surface, gn, is positive, the impermeability and separation conditions can be described by the Signorini complementarity relations:
g n ≥ 0 ,   p n ≥ 0 ,   g n p n = 0
When gn > 0, the pile and soil are in a separated state and pn = 0; when gn = 0, the interface is in contact and can transmit compressive normal pressure but no tensile normal traction. This formulation enables the local opening and separation of the pile–soil interface during pile uplift to be appropriately captured.
(3) Pile–Soil Tangential Friction Model
The uplift load carried by the pile is mainly transferred to the surrounding soil through tangential friction along the pile–soil interface. In this study, the Coulomb friction criterion was adopted to describe the tangential contact behavior at the interface, with the basic condition expressed as
τ t ≤ μ p n
where μ is the pile–soil interface friction coefficient, and μpn represents the limiting tangential friction that can be mobilized under the current normal contact pressure. The frictional contact constraint can be enforced using methods such as the penalty formulation, Lagrange multipliers, or the augmented Lagrangian method. In this study, the penalty formulation implemented in Abaqus was adopted. During the sticking stage, the relationship between tangential contact traction and relative tangential displacement can be approximately expressed as
τ t   =   k t Δ s t
where kt is the tangential penalty stiffness and Δst is the relative tangential displacement between the contacting surfaces. When the tangential contact traction reaches the frictional limit,
τ t = μ p n
the interface transitions from a sticking state to a sliding state. The penalty formulation allows a small amount of elastic slip during the sticking stage and approximately satisfies the tangential constraint through the penalty stiffness. As indicated by Equation (12), under the same normal contact pressure, increasing the interface friction coefficient increases the limiting tangential resistance that can be mobilized at the interface, thereby influencing the uplift stiffness of the pile foundation, the turning load of the load–displacement curve, and the internal load distribution within the pile group.
(4) Application of Initial Cable Prestress
In this study, the initial prestress of the cable members was introduced using the temperature-reduction method. The thermal strain of the cable material can be expressed as
ε T = α Δ T
where εT is the thermal strain, α is the coefficient of thermal expansion of the material, and ΔT is the temperature change. Under the idealized condition that both ends of the cable member are fully restrained and the overall structural deformation is neglected, the initial axial force induced by temperature reduction can be approximately expressed as
N 0 ≈ − EA α Δ T
where E and A are the elastic modulus and cross-sectional area of the cable member, respectively. When ΔT < 0, an initial tensile force is generated in the cable member. Since the cable members in the actual model differ in length, inclination angle, and connection position, coordinated deformation of the upper supported structure, main pile group, and anchorage piles also occurs. Therefore, Equation (16) is used only to illustrate the basic principle of prestress introduction by the temperature-reduction method, whereas the actual initial axial forces in the individual cable members are determined from the nonlinear finite element equilibrium solution. In summary, the finite deformation theory of beam elements, large-deformation frictional contact theory, and contact constraint treatment described above together constitute the theoretical basis of the numerical analysis conducted in this study.

2.3. Validation of the Proposed Model

To verify the correctness of the model, due to the complexity of the photovoltaic support structure, no real test data was obtained. Instead, the force-displacement curve of a single pile was used for model verification. Based on the PHC-600-130-C prestressed high-strength concrete of pile selected for the photovoltaic support pipe piles, the test results were compared with the numerical simulation results. The data from the two on-site loading pile foundation tests (GZK24-1 and GZK24-2) were used to establish a corresponding numerical pile foundation model according to the above theoretical model. The comparison of the H-Y curves between the test and the simulation is shown in Figure 2. Under the maximum test load of 51 kN, the measured displacement at the top of the pile was approximately 5.27 to 9.14 mm, while the numerical simulation was approximately 9 mm. The simulation curves of each pile were in good agreement with the measured curves. It should be noted that this validation is limited to the pile–soil interaction of isolated PHC piles and does not fully represent the behavior of the complete group-pile anchorage system. Group effects, pile–pile interaction, cable-prestress redistribution, the upper supported structure, the anchorage piles, and the full three-dimensional uplift response under extreme wind suction are not directly included in the validation test. Therefore, the single-pile comparison should be interpreted as component-level verification of the numerical formulation rather than as a full-scale validation of the complete anchorage system.
Figure 2. Comparison between measured and simulated load–displacement curves for the PHC-600-130-C pile.

3. Results and Discussion of Uplift Behavior of the Pile Group

3.1. Pile Distribution and Boundary Condition

To clarify the mechanical behavior of piles at different locations under the design loading condition, a unified numbering scheme was adopted for the main pile group and the anchorage piles on both sides. The main pile group was numbered A1–E3 according to its plan position, where the letters A–E denote the five pile rows in the longitudinal direction and the numbers 1–3 denote the three pile rows in the transverse direction. The anchorage piles on the two sides were numbered according to their positions relative to the wind direction, with W-AP denoting the four windward anchorage piles and L-AP denoting the four leeward anchorage piles. The plan layout and pile numbering are shown in Figure 3.
Figure 3. Plan layout and numbering scheme of the pile group.
To clarify the mechanical behavior and deformation characteristics of the group-pile anchorage system under the reference loading condition, the vertical axial forces at the pile heads and the corresponding vertical pile-head displacements were extracted for each main pile according to the numbering scheme shown in Figure 3, while the vertical responses of the anchorage piles on both sides were also evaluated. The analysis was not intended to represent a normal service condition. Instead, an extreme wind-suction condition corresponding to a design-level Level-14 typhoon, with a wind speed of approximately 41 m/s, was deliberately selected to represent the most unfavorable short-term uplift scenario for the cable-supported PV structure. The results are presented in Figure 4. As shown in Figure 4a, the main pile group exhibits a distinct pattern of “compression on both sides and tension in the middle.” Piles in rows A and E are generally subjected to compression, whereas piles in rows B, C, and D mainly carry uplift forces. In particular, the vertical tensile forces at the heads of piles B2, C2, and D2 are approximately 123.7, 134.4, and 144.8 kN, respectively, with pile D2 experiencing the largest uplift force. Pile E2 is subjected to a compressive force of approximately 185.1 kN, representing the maximum compression within the main pile group. Owing to the structural symmetry, except for the piles in row 2, the corresponding piles in rows 1 and 3 exhibit nearly identical vertical forces. This indicates that, under the combined action of wind suction and cable forces, the vertical load is primarily concentrated on piles B2, C2, and D2, while the compressive piles in rows A and E contribute to maintaining the overall equilibrium of the structural system.
Figure 4. Vertical responses of piles under the reference loading condition.
Overall, piles B2, C2, and D2 are identified as the primary uplift piles within the main pile group, while the windward anchorage piles exhibit the most pronounced uplift deformation under the reference wind-suction condition. Therefore, piles B2, C2, and the windward anchorage piles are treated as critical early-warning locations under the selected extreme condition. The leeward anchorage piles are additionally examined in the prestress and stiffness-degradation analyses because they are more sensitive to these parameters, although they are not the governing locations under the reference wind-suction condition.
As shown in Figure 4b, the displacement pattern of the main pile group is generally consistent with the distribution of tensile and compressive forces. Piles in rows A and E mainly exhibit downward displacement, whereas piles in rows B, C, and D are predominantly uplifted. The uplift displacements of piles B2, C2, and D2 are approximately 463.1, 320.1, and 50.6 mm, respectively. Although pile D2 carries the largest vertical tensile force, pile B2 exhibits the greatest uplift displacement, indicating that the vertical force and displacement responses at different pile locations do not correspond in a simple one-to-one manner. Instead, the deformation response is jointly affected by the load-transfer path of the upper structure, pile–soil constraints, and the coordinated interaction within the pile group. Because the present analysis corresponds to an extreme typhoon-related wind-suction condition, the calculated displacements exceeding the 100 mm threshold should not be interpreted as allowable service-state deformations. Instead, they are used as early-warning indicators of potential local pull-out and critical load-transfer paths under extreme environmental actions. The results identify piles B2, C2, and the windward anchorage piles as priority locations for monitoring, uplift-capacity assessment, and local strengthening in long-term service.
As shown in Figure 4c,d, the anchorage piles on both sides are generally subjected to tension. The vertical tensile forces of the windward anchorage piles are approximately 111–134 kN, with uplift displacements of about 195–257 mm, whereas the corresponding values for the leeward anchorage piles are approximately 79–104 kN and 20–30 mm, respectively. These results indicate that the windward anchorage piles experience more pronounced uplift action and deformation than the leeward piles. Overall, piles B2, C2, and D2 are identified as the primary uplift piles within the main pile group, while the windward anchorage piles exhibit the most pronounced uplift deformation under the reference wind-suction condition. Therefore, piles B2, C2, and the windward anchorage piles are treated as critical early-warning locations under the selected extreme condition. The leeward anchorage piles are ad”itio’ally examined in the prestress and stiffness-degradation analyses because they are more sensitive to these parameters, although they are not the governing locations under the reference wind-suction condition.
Under the reference loading condition, the vertical responses of the main pile group and the anchorage piles on both sides exhibit pronounced spatial differences. Piles B2, C2, and D2 are identified as the primary uplift piles within the main pile group, while the windward anchorage piles show considerably greater uplift responses than the leeward anchorage piles. To investigate the effects of different factors on the uplift behavior of the pile group, the local pile–soil interface friction coefficient, initial cable prestress, and local stiffness of the upper supported structure were varied separately based on the reference model. The uplift bearing capacity, deformation characteristics, and load redistribution behavior of the pile group were then evaluated through the load–displacement responses of the critical piles.

3.2. Effect of Local Variations in Pile–Soil Interface Friction

Pile–soil interface friction is an important factor governing the uplift response of pile foundations. Based on the vertical pile-head displacements under the reference loading condition presented in Section 3.1, a pile-head uplift displacement of 100 mm was adopted as the displacement control criterion. The uplift displacements of main piles B2 and C2 and the windward anchorage piles W-AP1, W-AP2, W-AP3, and W-AP4 all exceed this limit, indicating that these six piles undergo pronounced large deformation, whereas the remaining piles remain below the prescribed limit. Since the corresponding piles in rows 1 and 3 are symmetrically arranged and carry nearly identical loads, the subsequent uplift-response analysis focuses on these six critical piles. To eliminate the influence of the initial force and displacement states when comparing different cases, the corresponding initial values were subtracted from the load–displacement curves, thereby representing the incremental load–displacement responses of the critical piles induced by the applied external loads.
Under the reference extreme wind-suction condition, the pile–soil interface friction coefficient of all main piles was set to 0.25. Considering the internal friction angles of the muddy clay and silty sand layers, 17–20°, seen in Table 2, the corresponding interface friction coefficient range was taken as 0.25–0.35 to represent different roughness conditions of the PHC concrete pile–soil interface. While keeping the soil parameters, initial cable prestress, upper-structure stiffness, and external loading unchanged, the interface friction coefficients of the primary uplift piles B2 and C2 were simultaneously increased to 0.30 and 0.35, and the responses of the critical piles under the different cases were compared. To further clarify the influence of local variations in pile–soil interface friction on force transfer and load redistribution within the pile-group system, the incremental load–displacement curves of the critical piles were extracted, and the vertical tensile forces at the pile heads were also evaluated for each friction-coefficient case. By jointly comparing the pile-head load distributions and load–displacement responses, the effects of local interface-friction variations on load sharing within the photovoltaic support pile foundation, the uplift deformation of the critical piles, and the overall load redistribution characteristics can be further assessed.
As shown in Figure 5a,b, as the interface friction coefficient of piles B2 and C2 increases from 0.25 to 0.30 and 0.35, the ultimate uplift loads of both target piles increase markedly. The ultimate uplift load of B2 increases from approximately 120.85 kN to 141.81 and 144.8 kN, while that of C2 increases from approximately 134.4 kN to 154.27 and 175.67 kN. These results indicate that increasing the local pile–soil interface friction coefficient enhances the shaft resistance and delays relative slip at the pile–soil interface, thereby improving the uplift resistance of the target piles. As shown in Figure 5c,e, the load–displacement curves of the windward anchorage piles W-AP3 and W-AP1 under the three friction-coefficient cases nearly coincide, with only minor variations in the ultimate uplift load and post-peak deformation. This suggests that locally increasing the interface friction coefficients of B2 and C2 has only a limited influence on the uplift load–displacement response of the windward anchorage piles themselves. Although the overall variation in ultimate uplift load of W-AP3 and W-AP1 is small under the different friction-coefficient cases, differences are observed in their turning points and post-peak displacements. In particular, the ultimate uplift load of W-AP1 is higher than that of W-AP3, indicating a non-uniform load distribution among the anchorage piles due to differences in connection position, cable-force transmission, and spatial deformation of the upper supported structure.
Figure 5. Load–displacement curves and load distributions of critical piles under different local pile–soil interface friction coefficients.
Further examination of the vertical tensile-force distribution at the pile heads in Figure 5e shows that, as the interface friction coefficients of B2 and C2 increase, the vertical tensile forces carried by both target main piles exhibit an increasing trend, with a more pronounced increase observed for C2. In comparison, the changes in the pile-head tensile forces of the windward anchorage piles W-AP3 and W-AP1 remain relatively small. This indicates that improving the pile–soil interface friction of B2 and C2 enables the target piles to carry greater uplift loads and increases their share of the total load, while the force levels in the windward anchorage piles remain generally stable. Overall, locally increasing the pile–soil interface friction coefficients of B2 and C2 can effectively improve the uplift resistance of the target piles, but it also induces load redistribution among the main piles and between the main piles and windward anchorage piles. Therefore, optimization of local interface parameters should consider both the performance of individual piles and the coordinated load-bearing behavior of the pile-group system as a whole.

3.3. Effect of Cable Prestress

The initial cable prestress governs the internal load distribution of the large-span cable-supported structure. Because the cables connecting the main pile group and the anchorage piles on both sides differ in length and inclination, they were divided into two groups and assigned different initial cable forces. Under the low, medium, and high prestress levels, the initial cable forces of the two groups were set to 32 and 38 kN, 51 and 63 kN, and 69 and 87 kN, respectively. The initial cable prestress levels were determined by increasing and reducing the reference design cable forces of 51 and 63 kN by approximately 35–40%, covering possible construction tolerances, anchorage slip, relaxation, and long-term prestress loss. For common 15.2 mm–1860 Mpa steel strands, these levels correspond to approximately 0.12–0.33 fptk, which is well below the conventional tensioning-control limit of approximately 0.75 fptk. The soil parameters, pile–soil contact conditions, upper-structure stiffness, and external loading were kept unchanged. The vertical pile-head forces of representative piles in rows A and E of the main pile group, together with those of the windward and leeward anchorage piles, were extracted to compare the load redistribution within the pile group induced by variations in initial cable prestress, as shown in Figure 6. For the main piles, negative vertical forces indicate compression, whereas positive forces in the anchorage piles indicate tension.
Figure 6. Vertical responses of critical piles under different initial cable prestress levels.
As shown in Figure 6a, as the initial cable prestress increases from the low level to the high level, the vertical force responses of different piles within the main pile group vary to different degrees. In particular, the absolute values of the vertical compressive forces in piles A1 and A2 gradually increase, indicating that part of the main piles in row A carries greater downward force as the initial cable prestress increases. In contrast, the vertical compressive forces in piles E1 and E2 change only slightly, with E2 remaining nearly unchanged under the three prestress levels. This indicates that increasing the initial cable prestress does not cause a synchronous variation in the vertical loads of all main piles. Instead, it modifies the initial internal-force state and load-transfer path of the upper cable system, resulting in a certain degree of non-uniform load redistribution within the main pile group, with some piles in row A being more sensitive to variations in initial cable prestress.
As shown in Figure 6b,c, the anchorage piles on the two sides exhibit distinctly different responses to variations in the initial cable prestress. For the windward anchorage piles W-AP3 and W-AP1, the pile-head tensile forces vary only slightly among the low, medium, and high prestress levels, remaining relatively stable overall. In contrast, the pile-head tensile forces of the leeward anchorage piles L-AP3 and L-AP1 increase continuously as the initial cable prestress increases, indicating that higher prestress causes the leeward anchorage piles to sustain greater initial and final uplift forces, while its influence on the vertical loading of the windward anchorage piles is comparatively limited. This difference can be attributed to the different lengths, inclination angles, and connection positions of the cables on the two sides. As the initial cable prestress increases, the corresponding vertical force components and the incremental loads transferred through the upper supported structure to the foundation are distributed non-uniformly within the spatial system, making the leeward anchorage piles more sensitive to variations in prestress. Overall, increasing the initial cable prestress mainly changes the vertical force levels of certain piles in the main pile group and of the leeward anchorage piles. In particular, the uplift loads carried by the leeward anchorage piles increase with increasing prestress. Therefore, determination of the initial cable prestress should consider both the service performance of the upper cable system and the uplift demand of the leeward anchorage piles.

3.4. Effect of Local Stiffness Degradation of the Upper Supported Structure

In marine environments, the upper supported structure may experience stiffness reduction due to corrosion, connection damage, or localized deterioration of structural components. To investigate the influence of local stiffness degradation of the upper supported structure on load redistribution within the group-pile anchorage system, a longitudinal channel-steel member connecting piles A2 and A3 in row A on the leeward side of the main pile group was selected as the target component, while the soil parameters, initial cable prestress, and external loading were kept unchanged. The degree of local stiffness degradation was represented by reducing the elastic modulus of the selected member, with three cases of E, 0.6E, and 0.4E considered. A 40–60% reduction in the elastic modulus of a corroded or damaged steel member is a conservative scenario, not a prediction of a specific corrosion level; the range is consistent with the corrosion and reliability literature [13]. The vertical pile-head forces of the primary uplift piles B2, C2, and D2, the primary compression piles A1, A2, E1, and E2, and representative windward and leeward anchorage piles were extracted under the different stiffness conditions to evaluate the load redistribution within the pile-group system following local stiffness reduction of the upper supported structure, as shown in Figure 7. To further quantify the influence of stiffness degradation on the force response of individual piles, the intact-stiffness case E was taken as the reference, and the percentage changes in the absolute values of the vertical pile-head forces when the stiffness was reduced to 0.4E were calculated, with the results summarized in Table 3.
Figure 7. Vertical responses of critical piles under different levels of local stiffness degradation.
Table 3. Variation ratios of pile-head vertical forces when the local stiffness of the upper supported structure is reduced to 0.4E.
As shown in Figure 7a and Table 3, as the local stiffness is reduced from E to 0.4E, the vertical tensile forces in the main uplift piles generally increase, although the magnitude of change varies considerably among different pile locations. The vertical tensile force of pile B2 increases from 123.70 kN to 124.35 kN, corresponding to a change of only 0.52%, indicating that it is only slightly affected by the local stiffness degradation. In contrast, the tensile force of pile C2 decreases from 134.4 kN to 123.70 kN, representing a decrease of 7.96%, which is the most pronounced change among the main uplift piles. The tensile force of pile D2 increases from 144.83 kN to 149.38 kN, corresponding to an increase of 3.15%. By comparison, the response of the main compression piles is mainly characterized by a reduction in compressive force. Pile A1 remains nearly unchanged, whereas the absolute values of the vertical compressive forces in piles A2, E1, and E2 decrease by 8.79%, 11.32%, and 13.59%, respectively, with E2 exhibiting the largest reduction. These results indicate that local stiffness degradation of the upper supported structure modifies the original vertical load-transfer path within the main pile group, causing part of the load carried by the compression piles to be progressively released and redistributed to uplift piles such as C2 and D2. Among them, pile C2 exhibits relatively high sensitivity to local stiffness variations.
As shown in Figure 7b,c and Table 3, local stiffness degradation has distinctly different effects on the vertical forces of the windward and leeward anchorage piles. As the local stiffness decreases from E to 0.4E, the vertical tensile force of the windward anchorage pile W-AP3 remains nearly unchanged, with a variation of only −0.04%, while that of W-AP1 increases slightly by 1.26%, indicating that the windward anchorage piles are only weakly affected by local stiffness degradation. In contrast, the vertical tensile forces of the leeward anchorage piles increase more noticeably as the stiffness decreases. Specifically, the tensile force of L-AP3 increases from 104.91 kN to 111.33 kN, corresponding to an increase of 6.12%, while that of L-AP1 increases from 79.14 kN to 86.51 kN, representing an increase of 9.32%, the largest variation among the anchorage piles on both sides. These results indicate that local stiffness degradation of the longitudinal channel-steel member connecting piles A2 and A3 alters the original spatial load-transfer relationship of the upper supported structure, causing part of the vertical load to be redistributed toward the leeward anchorage piles, while the force levels of the windward anchorage piles remain generally stable. Considering the responses of both the main pile group and the anchorage piles, local stiffness degradation of the upper supported structure leads to pronounced non-uniform load redistribution within the pile-foundation system. The vertical tensile forces of the main uplift pile C2 decrease, and the leeward anchorage piles L-AP3 and L-AP1 increase, whereas the absolute compressive forces of the main compression piles A2, E1, and E2 decrease. This indicates that local stiffness degradation modifies the load-transfer path from the upper structure to the pile foundation, resulting in different degrees of increased force demand at specific pile locations.

4. Conclusions

By establishing beam and solid element models, the initial cable prestress was determined using the temperature-reduction method. Pile–soil interaction was simulated through frictional contact between the pile and soil, with the pile–soil interface friction coefficient set to 0.25, the initial cable forces of the two cable groups set to 51 and 63 kN, respectively, and the upper supported structure stiffness and design wind suction load applied under the reference extreme wind-suction condition. An integrated three-dimensional nonlinear finite element model of the upper supported structure–prestressed cables–main pile group–anchorage piles–layered seabed soil system was finally established. The present analysis was based on an extreme typhoon-related wind-suction condition rather than a normal service condition. Therefore, the results provide a reference for predicting the potential failure sequence and improving the long-term operational safety of offshore large-span cable-supported PV support structures. The main conclusions are summarized as follows:
(1)
Under the reference loading condition, the main pile group exhibits a mechanical response characterized by “compression on both sides and tension in the middle,” with piles B2, C2, and D2 serving as the primary uplift piles. Based on the 100 mm pile-head uplift displacement criterion, piles B2, C2, and the four windward anchorage piles enter a pronounced large-deformation state, indicating that the most unfavorable pile locations should be identified by considering both load-bearing capacity and deformation response. In engineering design, particular attention should be paid to the uplift capacity and deformation of piles B2, C2, and the windward anchorage piles, with appropriate safety reserves provided for these critical locations.
(2)
Some calculated pile-head displacements exceed the conventional displacement-control limit and should be interpreted as early-warning indicators of potential local failure under extreme environmental actions. From this perspective, the numerical results identify piles B2, C2, and the windward anchorage piles as the most vulnerable locations in the statically indeterminate anchorage system. Increasing the pile–soil interface friction coefficients of piles B2 and C2 can significantly improve their load-bearing performance, with a more pronounced increase observed for pile C2, while the responses of the windward anchorage piles remain relatively unchanged. This indicates that improving local interface properties primarily enhances the uplift resistance of the target piles, but also induces a certain degree of load redistribution within the pile group. In practical engineering applications, attention should be paid to the construction quality of the pile–soil interface at critical uplift pile locations, while avoiding excessive optimization of individual pile interface properties without considering the corresponding adjustments in load sharing among adjacent piles.
(3)
Increasing the initial cable prestress causes a non-uniform redistribution of vertical loads among the main pile group and the anchorage piles on both sides. In particular, the compressive forces of the main piles in row A increase, while the vertical tensile forces of the leeward anchorage piles exhibit a more pronounced increase. Therefore, the initial cable prestress should not be increased simply to achieve a higher value; instead, it should be reasonably determined based on the stiffness and stability requirements of the upper supported structure while considering the uplift resistance of the anchorage piles.
(4)
Local stiffness degradation of the upper supported structure significantly alters the load-transfer path within the pile-group system. In particular, the vertical tensile force of pile C2 decreases markedly, while the compressive forces of some main piles decrease and the tensile forces of the leeward anchorage piles increase. These results indicate that local stiffness degradation induces pronounced load redistribution effects within the structural system. During the service period, enhanced corrosion protection, inspection, and maintenance should be implemented for critical longitudinal channel-steel members and connection regions, with particular attention paid to the force variations in sensitive locations such as pile C2 and the leeward anchorage piles.
(5)
In addition, future work should emphasize realistic prediction of the long-term performance of offshore PV support structures under complex marine environmental conditions. The present analysis provides only a simplified assessment of marine-environment-induced stiffness degradation and prestress loss. Future studies should incorporate site-specific environmental data, long-term corrosion evolution, actual prestress variation, and coupled wind–wave–current actions to evaluate the remaining safety margin of the anchorage system under future extreme loading conditions. This will provide a more reliable basis for durability design, life-cycle assessment, and targeted maintenance of offshore large-span cable-supported PV pile foundations.

Author Contributions

X.J.: Conceptualization, methodology, software, formal analysis, investigation, and writing—original draft. Z.C.: Conceptualization, supervision, funding acquisition, and writing—review and editing. Y.Z.: Validation and data curation. D.C.: Software and visualization. G.C.: Investigation and resources. X.L.: Methodology and writing—review and editing. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by National Natural Science Foundation of China (No. 52278335) and the Cooperative Project of PowerChina Huadong Engineering Corporation Limited S (No. 2026350104000106).

Data Availability Statement

Data will be made available on request.

Acknowledgments

The authors would like to acknowledge the support of the National Natural Science Foundation of China and the Cooperative Project of PowerChina Huadong Engineering Corporation Limited S.

Conflicts of Interest

Authors Xianlin Jia and Yue Zhao were employed by the company PowerChina Huadong Engineering Corporation Limited. The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest. The authors declare that this study received funding from PowerChina Huadong Engineering Corporation Limited. The funder was not involved in the study design, collection, analysis, interpretation of data, the writing of this article or the decision to submit it for publication.

References

  1. Aly, A.M.; Bitsuamlak, G. Aerodynamics of ground-mounted solar panels: Test model scale effects. J. Wind Eng. Ind. Aerodyn. 2013, 123, 250–260. [Google Scholar] [CrossRef] [Scilit]
  2. Abiola-Ogedengbe, A.; Hangan, H.; Siddiqui, K. Experimental investigation of wind effects on a standalone photovoltaic (PV) module. Renew. Energy 2015, 78, 657–665. [Google Scholar] [CrossRef] [Scilit]
  3. Cao, J.; Yoshida, A.; Saha, P.K.; Tamura, Y. Wind loading characteristics of solar arrays mounted on flat roofs. J. Wind Eng. Ind. Aerodyn. 2013, 123, 214–225. [Google Scholar] [CrossRef] [Scilit]
  4. He, X.-H.; Ding, H.; Jing, H.-Q.; Zhang, F.; Wu, X.-P.; Weng, X.-J. Wind-induced vibration and its suppression of photovoltaic modules supported by suspension cables. J. Wind Eng. Ind. Aerodyn. 2020, 206, 104275. [Google Scholar] [CrossRef] [Scilit]
  5. Li, W.; Ke, S.; Cai, Z.; Ji, C.; Wang, W.; Wang, L.; Ren, H. Instability mechanism and failure criteria of large-span flexible PV support arrays under severe wind. Sol. Energy 2023, 264, 112000. [Google Scholar] [CrossRef] [Scilit]
  6. Potyondy, J.G. Skin friction between various soils and construction materials. Géotechnique 1961, 11, 339–353. [Google Scholar] [CrossRef] [Scilit]
  7. Lehane, B.M.; Jardine, R.J.; Bond, A.J.; Frank, R. Mechanisms of shaft friction in sand from instrumented pile tests. J. Geotech. Eng. 1993, 119, 19–35. [Google Scholar] [CrossRef] [Scilit]
  8. DeJong, J.T.; Westgate, Z.J. Role of initial state, material properties, and confinement condition on local and global soil-structure interface behavior. J. Geotech. Geoenviron. Eng. 2009, 135, 1646–1660. [Google Scholar] [CrossRef] [Scilit]
  9. Chattopadhyay, B.C.; Pise, P.J. Uplift capacity of piles in sand. J. Geotech. Eng. 1986, 112, 888–904. [Google Scholar] [CrossRef] [Scilit]
  10. De Nicola, A.; Randolph, M.F. Tensile and compressive shaft capacity of piles in sand. J. Geotech. Eng. 1993, 119, 1952–1973. [Google Scholar] [CrossRef] [Scilit]
  11. Butterfield, R.; Banerjee, P.K. The elastic analysis of compressible piles and pile groups. Géotechnique 1971, 21, 43–60. [Google Scholar] [CrossRef] [Scilit]
  12. Kayser, J.R.; Nowak, A.S. Reliability of corroded steel girder bridges. Struct. Saf. 1989, 6, 53–63. [Google Scholar] [CrossRef] [Scilit]
  13. Melchers, R.E. Modeling of marine immersion corrosion for mild and low-alloy steels: Part 1: Phenomenological model. Corrosion 2003, 59, 319–334. [Google Scholar] [CrossRef] [Scilit]
  14. Liu, J.; Li, S.; Luo, J.; Chen, Z. Experimental study on critical wind velocity of a 33-meter-span flexible photovoltaic supported structure and its mitigation. J. Wind Eng. Ind. Aerodyn. 2023, 236, 105355. [Google Scholar] [CrossRef] [Scilit]
  15. Xu, H.; Ding, K.; Shen, G.; Du, H.; Chen, Y. Experimental investigation on wind-induced vibration of photovoltaic modules supported by suspension cables. Eng. Struct. 2024, 299, 117125. [Google Scholar] [CrossRef] [Scilit]
  16. Liu, J.; Li, S.; Chen, Z. Experimental study on effect factors of wind-induced response of flexible photovoltaic supported structure. Ocean Eng. 2024, 307, 118199. [Google Scholar] [CrossRef] [Scilit]
  17. Zhu, Y.F.; Huang, Y.; Guo, Y.; Xiao, B.; Chen, C.H.; Yao, Y. Numerical assessment of the initial pre-tension impact on wind-induced vibration in flexible cable-supported photovoltaic systems. J. Wind Eng. Ind. Aerodyn. 2024, 251, 105788. [Google Scholar] [CrossRef] [Scilit]
  18. Wu, Y.; Wu, Y.; Sun, Y.; Sun, X. Wind-induced response and control criterion of the double-layer cable support photovoltaic module system. J. Wind Eng. Ind. Aerodyn. 2024, 254, 105928. [Google Scholar] [CrossRef] [Scilit]
  19. Choi, S.M.; Park, C.-D.; Cho, S.-H.; Lim, B.-J. Effects of various inlet angle of wind and wave loads on floating photovoltaic system considering stress distributions. J. Clean. Prod. 2023, 387, 135876. [Google Scholar] [CrossRef] [Scilit]
  20. Das, B.M.; Seeley, G.R.; Smith, J.E. Uplift capacity of group piles in sand. J. Geotech. Eng. Div. 1976, 102, 282–286. [Google Scholar] [CrossRef] [Scilit]
  21. Madhav, M.R. Efficiency of pile groups in tension. Can. Geotech. J. 1987, 24, 149–153. [Google Scholar] [CrossRef] [Scilit]
  22. Shelke, A.; Patra, N.R. Effect of arching on uplift capacity of pile groups in sand. Int. J. Geomech. 2008, 8, 347–354. [Google Scholar] [CrossRef] [Scilit]
  23. Reddy, K.M.; Ayothiraman, R. Experimental studies on behavior of single pile under combined uplift and lateral loading. J. Geotech. Geoenviron. Eng. 2015, 141, 04015030. [Google Scholar] [CrossRef] [Scilit]
  24. Al-Khazaali, M.; Vanapalli, S.K. Experimental investigation of single model pile and pile group behavior in saturated and unsaturated sand. J. Geotech. Geoenviron. Eng. 2019, 145, 04019112. [Google Scholar] [CrossRef] [Scilit]
  25. Ashour, M.; Abbas, A. Response of piles in multilayers of soil under uplift forces. Int. J. Geomech. 2020, 20, 04020056. [Google Scholar] [CrossRef] [Scilit]
  26. Zhou, Y.; Peng, R.; Xiang, Y.; Li, M.; Xi, G.; Li, Y.; Luo, N. Experimental investigation on wind loads and wind-induced responses of large-span flexible photovoltaic support structure. Eng. Struct. 2025, 322, 119009. [Google Scholar] [CrossRef] [Scilit]
  27. Qin, Y.; Ke, S.; Wang, B.; Ren, H.; Tian, W.; Cao, J. Research on aeroelastic effect of wind-induced vibration responses of large-span flexible photovoltaic support structure based on wind tunnel experiment comparison of rigid body and aeroelastic model. Sol. Energy 2025, 296, 113605. [Google Scholar] [CrossRef] [Scilit]
  28. Tong, C.; Han, F.; Chen, B.; Yang, Q. Nonlinear multi-objective equivalent static wind load for cable-supported photovoltaic arrays. Eng. Struct. 2026, 362, 122986. [Google Scholar] [CrossRef] [Scilit]
  29. Zhou, Y.; Xiang, Y.; Wang, W.; Zhao, J.; Yang, K.; Zhang, Y.; Li, M. Experimental study on wind-induced response on a 45 m span double-layer cable-supported photovoltaic structure with arrays. J. Wind Eng. Ind. Aerodyn. 2025, 266, 106213. [Google Scholar] [CrossRef] [Scilit]
  30. Li, J.; Nie, S.; Liu, M.; Yang, Q.; Guo, K. Two parallel cable trusses-supported photovoltaic system: Extreme wind-induced response and displacement-based gust response factors. J. Wind Eng. Ind. Aerodyn. 2025, 265, 106157. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.