Review Reports
- Junjie Yan 1,†,
- Mingxuan Lu 1,† and
- Tianyu Liu 1,*
- et al.
Reviewer 1: Anonymous Reviewer 2: Anonymous Reviewer 3: Anonymous
Round 1
Reviewer 1 Report
Comments and Suggestions for AuthorsThe manuscript entitled “Design and Optimization of a Vibratory Device for Embryo-Oriented Single-Row Conveying of Rice Seeds” presents an interesting engineering approach for the automated singulation and orientation of rice seeds. The integration of mechanical analysis, non-spherical DEM modelling, orthogonal experiments, high-speed photography, and response surface optimization represents a valuable aspect of the study. The reported performance of the optimized system, including an overall orientation success rate of 91.2% and a seed-flow uniformity coefficient of variation of 14.5%, is promising. However, several methodological and reporting issues should be addressed before the manuscript can be considered for publication.
- The center-of-mass asymmetry, which represents the fundamental physical principle of the proposed orientation mechanism, should be experimentally quantified. The manuscript repeatedly states that the center of mass is shifted toward the embryo end, and the parameter Δd is explicitly introduced in the tipping criterion of Equation (5). However, no experimental procedure or numerical value for this offset is reported. The authors should explain how the center-of-mass position was determined, report the number of seeds measured, provide the mean Δd together with an appropriate measure of variability, and clarify how biological variability among individual seeds affects the theoretical tipping criterion. The stabilizing moment used in Equation (5) should also be clearly defined and, where possible, quantified.
- The relationship between electrical operating voltage and the actual mechanical vibration conditions needs clarification. The theoretical formulation is based on vibration amplitude, angular frequency, excitation frequency, equivalent mass, and a frequency tuning ratio. In the experimental optimization, however, operating voltage is used as the main indicator of excitation intensity. The authors should provide measured or calibrated values of vibration amplitude and/or acceleration at the investigated voltage levels, or otherwise establish and justify the relationship between voltage and the mechanical excitation experienced by the seeds. The basis for the assumed frequency tuning ratio should also be explained more clearly.
- The DEM calibration procedure requires substantially more methodological detail to ensure reproducibility. The authors state that the interaction parameters were calibrated using bulk angle-of-repose and bulk-density tests, but the experimental configuration, number of repetitions, target values, parameter-search procedure, calibration errors, and acceptance criteria are not sufficiently described. Moreover, the experimentally reported mean seed dimensions (9.42 × 2.32 × 2.50 mm) differ from the representative DEM reconstruction dimensions (approximately 9.87 × 2.78 × 2.39 mm). The authors should clarify how the representative geometry was selected and discuss whether this dimensional difference may influence DEM predictions. Although the agreement between the predicted and measured conveying rates at the optimum condition is very good (approximately 205 versus 204 grains/min), validation at more than one operating condition would provide stronger evidence of model robustness.
- There appears to be an inconsistency in the selection of the optimum vibration frequency for the orientation module. According to Table 3, the three frequency levels are 99.5, 100.0, and 100.5 Hz. However, the range analysis in Table 7 reports , , and for this factor, which would indicate 100.0 Hz as the level associated with the highest mean response. Nevertheless, Section 3.2.2 identifies 99.5 Hz as the optimal value. This discrepancy should be carefully checked and corrected or justified. If 99.5 Hz was selected based on additional tests or another optimization criterion, those data and the corresponding rationale should be presented.
- The statistical treatment of the orientation-module experiments should be strengthened. Each orthogonal-test run used 200 seeds, comprising 100 forward-oriented and 100 reverse-oriented seeds, but it is not sufficiently clear whether these represent independent experimental replicates or observations within a single experimental run. The manuscript relies mainly on range analysis to establish the order of factor influence. An appropriate inferential analysis should be considered, and the number of independent replicates, variability, standard deviations or confidence intervals should be reported. Likewise, the ten bench-validation replicates produced retention and correction rates of 92.4% and 88.1%, respectively, but measures of dispersion are not provided.
- The response-surface analysis of the integrated system should be reported more completely. Table 9 provides F- and P-values, but the complete quadratic regression equations and additional model-quality statistics would improve transparency and reproducibility. In particular, please consider reporting , adjusted , predicted , coefficient of variation, and suitable residual/model-diagnostic information for both responses. The final validation is encouraging for orientation success rate, but the relative error for the seed-flow uniformity coefficient is 17.6% (predicted 12.3%, measured 14.5%). This difference should be discussed more critically, and variability across the five validation tests should be reported.
- The novelty and practical relevance of the proposed device would be clearer with a quantitative comparison against existing systems. The Introduction identifies an important gap concerning continuous integration of seed singulation and passive embryo reorientation. However, the Discussion would benefit from comparing the achieved throughput, orientation success rate, operational complexity, and main limitations with previously published seed-feeding or orientation systems. This comparison would allow readers to assess more clearly the technological advantage of the proposed two-stage configuration.
- Several additional methodological and presentation details should be addressed. The groove width is introduced as an important geometric constraint, but its final value is not clearly reported, while the manuscript mainly specifies the convergence angle . The derivation leading to this specific angle should also be explained more explicitly. The model, frame rate, image resolution, exposure settings, and other relevant specifications of the high-speed camera should be provided, together with more detail on the manual classification of seed orientation. Error bars and replicate information should be added to the relevant experimental figures where applicable. Figure 2 would benefit from a scale bar and clear indication of the embryo and endosperm ends. Terminology related to “transfer drop height”, “conveying drop height”, “seed conveying height”, and similar expressions should be standardized throughout the manuscript. Finally, the manuscript should undergo careful English-language editing to correct grammatical issues and improve consistency of technical terminology; for example, the sentence describing the bench-test platform contains an obvious grammatical interruption (“...Hunan Agricultural University. enabled independent adjustment...” ).
Overall, the manuscript addresses a relevant engineering problem and contains potentially valuable results. The combination of passive mechanical orientation and vibratory conveying is promising, and the experimental validation provides a useful basis for further development. Nevertheless, the points above—particularly the experimental characterization of the center-of-mass offset, the vibration parameters, DEM calibration and validation, statistical treatment, and the inconsistency concerning the optimum vibration frequency—should be carefully addressed to strengthen the scientific robustness and reproducibility of the study.
Comments on the Quality of English LanguageThe English is generally understandable, but moderate language editing is recommended to improve grammar, readability, and consistency of technical terminology.
Author Response
Please see the attachment.
Author Response File:
Author Response.pdf
Reviewer 2 Report
Comments and Suggestions for AuthorsThe manuscript has a clear engineering concept: a circular vibratory module for singulation followed by a stepped V-groove for passive orientation. The authors also provide DEM modelling, orthogonal testing, high-speed imaging and integrated RSM optimization.
However, I would emphasize the following issues that need to be addressed to improve the overall quality of manuscript.
- The introduction can be made more focused. The references are generally relevant and cover molecular breeding, seed sampling, machine vision, vibratory conveying and DEM. However, the literature review would benefit from a more systematic comparison of existing seed orientation mechanisms, especially specific quantitative performance data from previous rice/seed-orientation systems.
- The orthogonal experiment has only nine runs, and the manuscript reports factor influence using the range R but does not provide an ANOVA/significance analysis for this experimental stage. This makes it difficult to establish statistically whether the claimed factor effects are significant.
- Ten replicated bench tests are mentioned, but the manuscript should clearly state the number of seeds evaluated in each replicate, whether percentages were calculated separately and averaged or obtained by pooling observations, and preferably provide mean ± SD/SE and confidence intervals.
- The predicted orientation success rate was 93.0%, whereas the measured value was 91.2%. The predicted coefficient of variation was 12.3% compared with 14.5% experimentally, corresponding to a reported relative error of 17.6%. This discrepancy should be discussed more critically.
- The introduction discusses vision-based, mechanical, pneumatic and vibratory approaches, but the experimental section does not appear to provide a benchmark against an existing rice-seed orientation/singulation system. Consequently, the practical superiority of the proposed system is difficult to establish.
- The predicted conveying rate of approximately 205 grains/min and experimental value of 204 grains/min are close, which is encouraging. However, the manuscript should report the variability/uncertainty of the experimental measurements and explain more clearly how DEM calibration parameters were obtained and validated.
- The mechanical diagrams and high-speed photography are useful, but some figures contain substantial information in relatively small graphics. Figure 9, for example, contains several sequential images and should be made larger/clearer if possible.
The manuscript is generally understandable, but the English language requires moderate improvement to enhance clarity, readability, and scientific precision. Several sentences are lengthy or structurally complex, and some expressions are or repetitive. The terminology and tense should also be used consistently throughout the manuscript, particularly when describing experimental procedures, results, and mechanistic interpretations. Careful language editing is recommended to improve sentence structure, grammar, transitions between paragraphs, and overall readability.
Author Response
Please see the attachment.
Author Response File:
Author Response.pdf
Reviewer 3 Report
Comments and Suggestions for AuthorsThe manuscript “Design and Optimization of a Vibratory Device for Embryo-Oriented Single-Row Conveying of Rice Seeds” presents a two-stage vibratory system for rice seed singulation and embryo orientation, combining a circular vibratory conveying module and a stepped V-groove passive orientation module. The topic is relevant to automated rice breeding and half-seed sampling, where embryo alignment is important to avoid embryo damage during cutting. The manuscript has several strengths: a clear engineering problem, a well-described two-stage device, DEM-based conveying simulation, orthogonal and response-surface optimization, high-speed photographic verification, and physical bench validation. The reported final performance—91.2% orientation success rate and 14.5% coefficient of variation for seed-flow uniformity—is promising.
However, the manuscript requires good revision. The comments are given below.
1. The introduction identifies three unresolved problems: the passive orientation mechanism of asymmetric rice seeds, the relationship among seed properties, V-groove geometry, and single-row posture constraint, and the lack of a continuous two-stage process linking fluidization, single-row conveying, and passive embryo reorientation. These are appropriate gaps. However, vibratory bowls, passive orientation structures, DEM simulation, and response-surface optimization are established methods. Author should revise the novelty as the application and integration of a two-stage vibratory singulation–orientation system for embryo-oriented rice seed preprocessing, supported by DEM and bench validation. Avoid implying that vibratory orientation or DEM-based optimization itself is new.
2. The center-of-mass offset is central but insufficiently quantified. The proposed orientation mechanism depends on the asymmetric center of mass of rice seeds. The manuscript states that the center of mass shifts toward the embryo end, but it does not report the measured offset distance, measurement method, sample size, variation among seeds, or statistical distribution. Author should add a quantitative center-of-mass characterization. Report the method used to determine the embryo-end mass offset, the number of seeds measured, mean ± SD, range, and coefficient of variation. Since the tipping criterion depends on this offset, the value should be directly incorporated into the mechanical analysis and discussed as a source of orientation variability.
3. The DEM model was constructed using a 3D scanned rice seed and 24 multi-sphere filling, and the contact parameters were calibrated using bulk angle of repose and bulk density tests. However, the calibration procedure is not described in enough detail, and only final parameters are listed. The agreement between DEM-predicted throughput and bench throughput is promising, but a single throughput comparison is not enough to validate the DEM model broadly. Author should provide the full DEM calibration procedure, including test setup, number of repetitions, target values, simulated vs. measured angle of repose and bulk density, calibration error, contact model, time step, solver settings, particle number, and boundary conditions. Add validation beyond final throughput, such as seed distribution, flow pattern, conveying time, jamming frequency, or velocity profile.
4. The experimental material was limited to “Y Liangyou 900,” with specific dimensions, moisture content, and thousand-grain weight. The authors acknowledge that cultivar, morphology, glume roughness, and center-of-mass distribution may affect the V-groove constraint and passive tipping behavior. This limitation should be stated more strongly in the abstract, discussion, and conclusion. If possible, add validation using at least one japonica and one additional indica cultivar. If not possible, describe the device as optimized for one long-grain hybrid rice cultivar and avoid broad claims about rice seeds in general.
5. High-speed photography is used to verify seed reorientation at the step edge, and the images show typical forward-flow and reverse-to-forward transition states. However, the analysis remains mostly qualitative. The manuscript states that failures were caused by trichome interlocking, local crowding, or transient contact forces, but these error types are not quantified. Author should add quantitative kinematic analysis from high-speed videos, including rotation angle, angular velocity, tipping time, contact duration, and success/failure counts by failure type. A table classifying orientation failures would make the proposed mechanism more convincing.
6. The orientation module used 200 seeds per test run, with 100 forward-oriented and 100 reverse-oriented seeds, and the optimized condition was verified with ten replicated bench tests. The integrated system was verified using five validation tests, producing 91.2% orientation success and 14.5% coefficient of variation. However, the manuscript mainly reports averages and does not provide SD, confidence intervals, or statistical comparisons. Author should revise: and add mean ± SD or 95% confidence intervals for all key metrics: conveying rate, forward retention rate, reverse correction rate, total orientation success rate, and uniformity coefficient. Include the number of seeds per replicate and total seeds evaluated. Statistical tests should be used to compare factor levels and optimized vs. non-optimized conditions.
7. The manuscript states that embryo posture was manually verified from high-speed image sequences, and the seed-flow uniformity index was based on manual counting over five 1-s intervals. Manual evaluation may introduce subjectivity, especially when seeds overlap, move quickly, or are partially blurred. Author needs to describe the manual evaluation protocol more clearly. State whether one or more observers counted the seeds, whether repeatability was checked, and whether ambiguous cases were excluded. If possible, introduce automated or semi-automated image analysis to determine seed posture and flow rate, or at least report observer agreement.
8. The optimized circular vibratory module achieved about 204 grains/min, while the integrated system achieved 91.2% orientation success. However, the manuscript does not compare this throughput with the actual demand of high-throughput molecular breeding, half-seed cutting, or downstream genotyping equipment. Please add a practical throughput discussion. Compare the device output rate with the required feed rate of rice half-seed cutting systems and molecular breeding workflows. Also discuss whether the 8.8% misorientation rate is acceptable for embryo-preserving cutting, or whether an additional detection/rejection stage is needed.
9. The manuscript uses DEM-based Box–Behnken design for the conveying module, orthogonal tests for the orientation module, and Box–Behnken design for the integrated system. This is reasonable, but some parts need stronger statistical interpretation. For example, the integrated-system interaction terms were not significant, while the models were dominated by main and quadratic effects. Provide the regression equations for the response-surface models, including coded and actual variables. Report residual diagnostics, predicted vs. measured plots, model adequacy checks, and confidence intervals for the optimum. For the orthogonal test, consider adding ANOVA, not only range analysis, to statistically support the factor influence order.
10. The discussion acknowledges that changes in moisture content, glume surface condition, and cultivar morphology may alter friction and restitution parameters. However, all reported experiments appear to use one seed batch at about 11% moisture content. Author should add robustness tests at different seed moisture contents and seed surface conditions if possible. At minimum, discuss how drying, storage duration, dust, broken glumes, and seed size variation may affect conveying, clogging, and orientation performance.
11. The manuscript mentions no obvious clogging or severe bouncing under the optimized orientation-module condition, and it also notes that excessive flow can reduce performance due to inter-particle forces and interlocking. However, long-duration reliability, clogging frequency, misorientation rate, seed damage, and machine stability are not sufficiently reported. Author nned to add a reliability test, for example a continuous 30–60 min operation test. Report total seeds processed, clogging events, misoriented seeds, repeated flips, seed breakage, embryo damage risk, and throughput stability over time. This is important for practical breeding-line integration.
12. The conclusion clearly summarizes the optimized parameters and final results, including 204 grains/min conveying rate, 92.4% forward retention, 88.1% reverse correction, 91.2% overall orientation success, and 14.5% uniformity CV. However, it should also clearly state what remains unverified: downstream cutting accuracy, embryo survival, germination after processing, cultivar adaptability, long-term reliability, and system integration. Author needs to revise the conclusion to state that the device provides a promising pre-processing module for embryo-oriented rice seed conveying, but practical use in molecular breeding requires integration with a cutting module, embryo-damage evaluation, germination testing, multi-cultivar validation, and long-duration operation testing.
13. The manuscript requires careful language and formatting editing. Some equations and symbols are difficult to read in the PDF, and several variables are not clearly defined at first use. Please use consistent notation for operating voltage because both the circular and linear vibrators appear to use similar symbols.
14. Figure captions should be more informative, especially Figures 9–13.
Comments on the Quality of English LanguageThe manuscript requires careful language and formatting editing.
Author Response
Please see the attachment.
Author Response File:
Author Response.pdf
Round 2
Reviewer 1 Report
Comments and Suggestions for AuthorsThe revised manuscript has improved substantially compared with the previous version. The authors have addressed many of the methodological and interpretative concerns raised during the first review round, and the paper is now clearer, more transparent, and scientifically more robust. In particular, I appreciate the new quantitative characterization of the embryo-end center-of-mass offset, based on repeated measurements of 50 individually identified seeds, and the subsequent paired tipping experiments performed on the same seeds. These additions provide a much stronger experimental basis for the proposed passive reorientation mechanism. The characterization of the local vibration field using an accelerometer, together with the reported repeatability and uncertainty, also significantly improves the physical interpretation of the tipping process. The DEM section has also been strengthened. The manuscript now describes the calibration procedure more clearly and extends the comparison between DEM predictions and bench measurements beyond the single optimized condition. The validation across 11 conditions, with low MAPE and high correlation between simulated and experimental throughput, provides a more convincing basis for the use of the DEM model within the investigated operating range. I also consider the revised statistical treatment of the orthogonal experiment appropriate. The authors now correctly acknowledge that the L9 design does not provide an independent residual-error term for inferential ANOVA and therefore interpret the range analysis descriptively. The selected configuration is subsequently evaluated through ten independent bench runs, which substantially strengthens the experimental evidence. The manuscript is close to publication. However, I suggest addressing the following remaining minor points before acceptance:
- Final validation of the integrated RSM optimum.
Five validation tests were conducted at the optimized operating condition, and mean values of 91.2% for orientation success and 14.5% for the seed-flow-uniformity coefficient of variation are reported. If the individual run-level values are available, I recommend reporting the corresponding standard deviation and, preferably, confidence intervals. This would make the repeatability of the final optimized configuration more transparent.
- Interpretation of the robustness experiment.
The robustness screening across moisture content, storage state, and seed-surface condition is useful, but each condition was evaluated only once. The manuscript already recognizes that these data are descriptive and cannot support factorial statistical inference. I recommend maintaining this cautious interpretation consistently throughout the Results, Discussion, Abstract, and Conclusions, avoiding any wording that could imply statistically demonstrated robustness.
- Tipping criterion and Equation (5).
The revised manuscript appropriately states that the proposed tipping criterion is supported at the trend and order-of-magnitude levels but is not yet a deterministic seed-level predictor. Please ensure that this interpretation is consistent throughout the manuscript. Terms such as “verified”, “confirmed”, or similar definitive expressions should be used with caution when referring specifically to Equation (5), since the available evidence does not yet establish a fully validated predictive threshold.
- Scope of generalization.
The authors now clearly acknowledge that all characterization, optimization, and robustness experiments were conducted using one batch of the cultivar ‘Y Liangyou 900’. This limitation should remain clearly visible in the Abstract and Conclusion, particularly because seed geometry, friction, glume properties, and center-of-mass distribution may differ among cultivars.
- Practical interpretation of residual misorientation.
The discussion appropriately notes that an integrated orientation success rate of 91.2% still corresponds to a non-negligible fraction of incorrectly oriented seeds and that this cannot automatically be considered sufficient for embryo-preserving cutting. I encourage the authors to preserve this important caveat and avoid presenting the current device as a complete stand-alone solution for automated half-seed cutting until downstream cutting accuracy, embryo survival, and germination are experimentally validated.
Overall, the revised manuscript is significantly stronger and addresses the major concerns of the previous review round. The remaining issues mainly concern reporting completeness and careful interpretation of the experimental scope rather than fundamental methodological weaknesses. I therefore recommend Minor Revision.
Author Response
Please see the attachment.
Author Response File:
Author Response.pdf
Reviewer 2 Report
Comments and Suggestions for AuthorsLimited run-level variability reporting should either be corrected further or very clearly retained as limitations.
Author Response
Please see the attachment.
Author Response File:
Author Response.pdf