Abstract
Background/Objectives: We compared refractive outcomes, corneal higher-order aberrations (HOAs), and asphericity (Q-value) after Custom-Q laser in situ keratomileusis (CQ-LASIK), Custom-Q photorefractive keratectomy (CQ-PRK), and keratorefractive lenticule extraction (KLEx), three treatment approaches rarely compared directly. Methods: This retrospective cohort study included 214 eyes of 107 patients treated with CQ-LASIK (62 eyes), CQ-PRK (78 eyes), or KLEx (CLEAR, FEMTO LDV Z8; 74 eyes) (2023–2025; 6.5-mm optical zone). Coma, trefoil, primary spherical aberration (SA), and total HOAs at 2.0–7.0 mm and Q-values at 6.0–9.0 mm were compared preoperatively and at 6 months using generalized estimating equations accounting for inter-eye correlation, with Bonferroni-adjusted pairwise comparisons. Results: Uncorrected distance visual acuity was 20/20 or better in 95%, 96%, and 96% of eyes, and the spherical equivalent was within ±1.0 D in 96.6%, 97.9%, and 97.4% after CQ-LASIK, CQ-PRK, and KLEx, respectively. Induced coma and trefoil did not differ among the groups at any diameter. At 5.0 mm, induced SA was greater after CQ-PRK than after CQ-LASIK or KLEx; at 6.0 and 7.0 mm it followed the order CQ-PRK > CQ-LASIK > KLEx (6.0 mm: 0.31, 0.09, and 0.03 µm), as did the oblate Q-value shift (all adjusted p < 0.05); a one-eye-per-patient sensitivity analysis was consistent. Conclusions: At 6 months, the three procedures corrected refraction comparably and preserved central corneal optics but differed in peripheral corneal optical profiles, with induced SA and oblate shape change greatest after CQ-PRK and smallest after CLEAR-based KLEx. These modest differences require prospective confirmation of their effect on visual function.
1. Introduction
Corneal refractive surgery for myopia and myopic astigmatism has evolved beyond the simple correction of refractive error toward the preservation of optical quality. Higher-order aberrations (HOAs)—particularly spherical aberration (SA) and coma—are inevitably induced during corneal reshaping and have been associated with glare, halos, and reduced contrast sensitivity [1,2]. When the central cornea is flattened to correct myopia, corneal asphericity (Q-value) shifts in the positive (oblate) direction and positive SA increases [3,4]. To attenuate this shift, Custom-Q aspheric ablation, which sets each patient’s preoperative asphericity as the ablation target, was introduced. It has been reported to limit the increase in SA more effectively than wavefront-optimized ablation [5].
Keratorefractive procedures are commonly classified into laser in situ keratomileusis (LASIK), photorefractive keratectomy (PRK), and keratorefractive lenticule extraction (KLEx) according to how and where corneal tissue is removed. Because the treatment profile, corneal biomechanical response, and wound-healing behavior differ among these approaches, the pattern of surgically induced HOAs may also differ. Even with the same Custom-Q ablation profile, surface ablation has been reported to induce greater SA than LASIK [6], whereas lenticule extraction relatively well preserves corneal asphericity and induces less SA [7]. Individual pairwise comparisons of these procedures have been reported [8,9,10,11]. However, direct three-way comparisons of Custom-Q LASIK (CQ-LASIK), Custom-Q PRK (CQ-PRK), and KLEx performed under comparable conditions—the same 6.5-mm optical zone, the same femtosecond laser platform for flap and lenticule creation, an overlapping range of attempted corrections, and the same center and surgeons—remain scarce.
Furthermore, because Zernike-based corneal HOAs depend strongly on the analysis diameter, examining aberration changes at several corneal diameters rather than at a single diameter provides a more complete optical profile of each procedure and can reveal the corneal region in which the procedures actually differ [10,12].
Therefore, in this study, we directly compared refractive and visual outcomes, diameter-specific changes in corneal HOAs at 2.0- to 7.0-mm diameters, and corneal asphericity changes at 6.0- to 9.0-mm diameters 6 months after CQ-LASIK, CQ-PRK, and KLEx. Because the three procedures differ not only in ablation profile but also in laser platform and surgical technique, the study was designed to describe the corneal optical profile of each treatment approach as a whole rather than to isolate the effect of any single factor.
2. Materials and Methods
2.1. Study Design and Population
This retrospective cohort study was based on the medical records of patients who underwent CQ-LASIK, CQ-PRK, or KLEx for the correction of myopia or myopic astigmatism at a single eye center between January 2023 and January 2025. All consecutive patients who underwent one of the three procedures during this period, met the eligibility criteria, and completed at least 6 months of postoperative follow-up were included. The study adhered to the tenets of the Declaration of Helsinki and was approved by the Institutional Review Board of the participating institution (approval no. FSEC-202512-HRR001-01). The requirement for informed consent was waived owing to the retrospective nature of the study.
During the study period, 161 patients (322 eyes) underwent one of the three procedures. Eyes with signs of ectatic corneal disease including keratoconus, ophthalmic comorbidities such as cataract, glaucoma, uveitis, or retinal disease, or a history of previous corneal refractive surgery were excluded, as were patients with incomplete preoperative tomographic data (n = 20 patients excluded in total). Of the 141 eligible patients, 34 did not complete the 6-month visit and were not analysed, leaving 214 eyes of 107 patients, all of whom contributed both eyes (Figure 1). The patients were classified by surgical technique into the CQ-LASIK group (62 eyes of 31 patients), the CQ-PRK group (78 eyes of 39 patients), and the KLEx group (74 eyes of 37 patients). The mean age was 25.90 ± 6.13 years (range, 18–43 years); 57 patients were male, and 50 were female. Baseline refractive, keratometric, pachymetric, and treatment parameters of the three groups are summarized in Table 1. The surgical modality was determined according to patient preference after detailed consultation regarding baseline corneal thickness, topographic patterns, and the magnitude of refractive error.
Figure 1.
Flow diagram of patient selection. Numbers of patients screened, excluded, lost to follow-up before 6 months, and included in the analysis are shown by surgical group. CQ-LASIK, Custom-Q laser in situ keratomileusis; CQ-PRK, Custom-Q photorefractive keratectomy; KLEx, keratorefractive lenticule extraction; CLEAR, corneal lenticule extraction for advanced refractive correction; HOA, higher-order aberration; GEE, generalized estimating equations.
Table 1.
Baseline demographic, refractive, and corneal characteristics of the study population by surgical group.
2.2. Surgical Procedures
All surgeries were performed by two experienced surgeons using a standardized protocol, and the optical zone was set at 6.5 mm in all three groups.
In the CQ-LASIK and CQ-PRK groups, excimer laser ablation was performed using the WaveLight EX500 excimer laser platform (Alcon Laboratories, Fort Worth, TX, USA) with the Custom-Q protocol; the iris image obtained preoperatively with the Topolyzer Vario (Alcon Laboratories) was used for registration, and the target asphericity was set to each patient’s preoperative Q-value. The 6.5-mm optical zone was surrounded by the platform’s standard aspheric transition zone. In the CQ-LASIK group, the corneal flap was created using the FEMTO LDV Z8 femtosecond laser platform (Ziemer Ophthalmic Systems AG, Port, Switzerland) with a planned flap thickness of 90 µm, a flap diameter of 8.6 mm, and a superior hinge. In the CQ-PRK group, the corneal epithelium was removed over a diameter of approximately 8.0 to 9.0 mm using an Amoils brush (6.5 mm), followed by the same excimer laser ablation; 0.02% mitomycin C was then applied for 1 min to the stromal bed in all eyes and rinsed with chilled balanced salt solution.
In the KLEx group, all eyes were treated with the CLEAR (corneal lenticule extraction for advanced refractive correction) software (corneal application software version 4.13.1.19661) on the FEMTO LDV Z8 platform, with a cap thickness of 110 µm, a lenticule optical zone diameter of 6.5 mm, and the platform’s default cap diameter and transition zone. To compensate for cyclotorsion, ocular surface data were obtained preoperatively with the Argos optical biometer (Alcon Laboratories) and used intraoperatively with the digital marker microscope (Alcon Laboratories) to mark, on the corneal mid-periphery, the points corresponding to the visual axis and to the 0° and 90° corneal astigmatism axes. After docking, the lenticule profile overlaid on the live corneal image was centered on the visual axis, and the cardinal cross-lines were rotated to coincide with the corneal marks before proceeding.
In all groups, the residual stromal bed thickness was planned to be at least 300 µm and, when possible, at least 330 µm to preserve the possibility of future re-treatment; the planned maximum ablation depth (or lenticule thickness) and residual stromal bed thickness of each eye were retrieved from the treatment records (Table 1). According to the institutional postoperative protocol, a therapeutic contact lens was applied to all eyes immediately after surgery in all three groups; it was removed on postoperative day 4 in the CQ-PRK group and on postoperative day 1 in the CQ-LASIK and KLEx groups.
2.3. Clinical and Optical Assessments
Visual acuity testing and manifest refraction were performed preoperatively and at 6 months postoperatively to obtain the manifest refraction spherical equivalent (MRSE), sphere, and cylinder. Corneal curvature (flat and steep keratometry), central corneal thickness, corneal HOAs, and corneal asphericity (Q-value) were measured using a Scheimpflug-based corneal tomographer (Pentacam HR; Oculus Optikgeräte GmbH, Wetzlar, Germany). Only acquisitions with the device’s quality specification marked as “OK” were used. Corneal HOAs were obtained from the Zernike analysis module of the Pentacam software, version 1.22r05 (anterior corneal surface), in which the analysis diameter was set manually to 2.0, 3.0, 4.0, 5.0, 6.0, and 7.0 mm in turn, centered on the corneal apex; no additional third-party software was used. Coma, trefoil, primary SA, and total HOA root mean square (RMS) were recorded at each diameter, and Q-values were read from the same examination at the 6.0-, 7.0-, 8.0-, and 9.0-mm diameters, both preoperatively and at 6 months; surgically induced changes were calculated as postoperative minus preoperative values. For each analysis diameter, the Zernike expansion was computed directly by the device from the elevation data acquired at that diameter; coefficients were not rescaled or extrapolated from a single reference pupil size. All aberration values are expressed in micrometers (µm); primary SA is reported as the signed Zernike coefficient (C40), whereas coma, trefoil, and total HOAs are reported as RMS values.
Astigmatic changes were evaluated using the Alpins vector analysis method. Target-induced astigmatism (TIA) was defined as the intended astigmatic change and surgically induced astigmatism (SIA) as the astigmatic change actually achieved. The difference vector (DV) was defined as the additional astigmatic change required to reach the intended correction, and the magnitude of error (ME) as the arithmetic difference between SIA and TIA. The correction index (CI; SIA divided by TIA) and the index of success (IS; DV divided by TIA) were calculated to evaluate surgical precision and efficiency.
2.4. Statistical Analysis
Because both eyes of every patient were included, all between-group comparisons were performed using generalized estimating equations (GEE) with an identity link, an exchangeable working correlation structure, and robust (sandwich) standard errors, with the patient as the clustering unit, so that the correlation between fellow eyes was accounted for. For each outcome, the group effect was tested with the GEE Wald test, and pairwise comparisons among the three groups were performed with Bonferroni correction for three comparisons; Bonferroni-adjusted p-values and Bonferroni-adjusted 95% confidence intervals (CIs) of the mean differences are reported throughout, and an adjusted p < 0.05 was considered significant. Between-group comparisons of proportions were performed with the chi-square test. Within-group preoperative-to-postoperative comparisons at each diameter were performed using the paired t-test; these comparisons were considered descriptive and exploratory and were not adjusted for multiplicity across diameters. As a sensitivity analysis, one eye per patient was selected at random using a random-number generator with a fixed seed before analysis, and the primary comparisons at the 6.0-mm diameter were repeated using one-way analysis of variance with Bonferroni post hoc tests (Supplementary Table S1). In addition, the primary comparisons at 6.0 mm were repeated in GEE models adjusted for preoperative central corneal thickness, MRSE, and ablation depth (or lenticule thickness). Statistical analyses were performed using IBM SPSS Statistics version 29.0 (IBM Corp., Armonk, NY, USA).
3. Results
3.1. Refractive and Visual Outcomes
The baseline characteristics of the study population are presented in Table 1. The three groups were comparable with respect to preoperative refraction, keratometry, central corneal thickness, 6.0-mm Q-value and total HOA, planned ablation depth or lenticule thickness, and residual stromal bed thickness (all p > 0.05). The refractive outcomes are summarized in Table 2. At 6 months, all three groups showed significant reductions in spherical equivalent, sphere, cylinder, and corneal curvature compared with preoperative values, with no significant intergroup differences in any preoperative or postoperative refractive parameter (Table 2).
Table 2.
Refractive, visual, and keratometric outcomes before and 6 months after surgery.
Postoperative uncorrected distance visual acuity (UDVA) was 20/20 or better in 95% of eyes in the CQ-LASIK group, 96% in the CQ-PRK group, and 96% in the KLEx group, and 20/16 or better in 84%, 85%, and 86% of eyes, respectively (Figure 2a; Table 2). The postoperative MRSE was within ±0.5 D of the intended target in 82.3%, 85.6%, and 78.8% of eyes and within ±1.0 D in 96.6%, 97.9%, and 97.4% of eyes in the CQ-LASIK, CQ-PRK, and KLEx groups, respectively (Figure 2b); none of these proportions differed significantly among the groups (Table 2). Linear regression of achieved against attempted MRSE yielded y = 0.99x + 0.06, y = 1.03x + 0.04, and y = 0.96x − 0.08 with a coefficient of determination (R2) of 0.98, 0.96, and 0.98, respectively (Figure 2c). Refractive astigmatism of 0.5 D or less was achieved in 68.8%, 69.5%, and 72.4% of eyes, respectively (Figure 2d). No significant intergroup differences were observed in any Alpins vector analysis index (TIA, SIA, DV, ME, CI, and IS; all p > 0.05) (Table 3). The correction index was below 1.0, and the magnitude of error was negative in all three groups, indicating a similar degree of mild undercorrection of astigmatism.
Figure 2.
Refractive and visual outcomes of CQ-LASIK, CQ-PRK, and KLEx at 6 months. (a) Efficacy: cumulative distribution of postoperative UDVA compared with preoperative CDVA. (b) Predictability: distribution of postoperative MRSE relative to the intended target. (c) Predictability: scatter plot and linear regression of attempted versus achieved MRSE (CQ-LASIK: y = 0.99x + 0.06, R2 = 0.98; CQ-PRK: y = 1.03x + 0.04, R2 = 0.96; KLEx: y = 0.96x − 0.08, R2 = 0.98). (d) Astigmatism: distribution of preoperative and postoperative refractive astigmatism. MRSE, manifest refraction spherical equivalent; UDVA, uncorrected distance visual acuity; CDVA, corrected distance visual acuity; CQ-LASIK, Custom-Q laser in situ keratomileusis; CQ-PRK, Custom-Q photorefractive keratectomy; KLEx, keratorefractive lenticule extraction.
Table 3.
Alpins vector analysis of astigmatic correction at 6 months.
3.2. Diameter-Specific Changes in Corneal Higher-Order Aberrations
Preoperative corneal HOAs did not differ among the three groups at any diameter from 2.0 to 7.0 mm (Supplementary Table S2). In the within-group analysis, no significant preoperative-to-postoperative change occurred at the 2.0-mm diameter in any group. Coma and total HOAs increased significantly from the 3.0-mm diameter onward in the CQ-PRK group, from the 4.0-mm diameter onward in the CQ-LASIK group, and from the 4.0-mm (coma) and 5.0-mm (total HOAs) diameters onward in the KLEx group. Primary SA increased significantly over preoperative values from the 5.0-mm diameter in the CQ-PRK group and from the 6.0-mm diameter in the CQ-LASIK and KLEx groups, and trefoil showed a small but significant increase only at the 7.0-mm diameter in all three groups (Supplementary Table S2).
In the intergroup comparison of surgically induced changes (Table 4; Figure 3), no significant differences were found among the three procedures at the 2.0- to 4.0-mm diameters for any aberration. Intergroup differences in induced primary SA emerged at the 5.0-mm diameter, where the change was significantly greater in the CQ-PRK group than in the CQ-LASIK (mean difference 0.13 µm; Bonferroni-adjusted 95% CI 0.11 to 0.15) and KLEx (0.11 µm; 0.08 to 0.14) groups. At the 6.0- and 7.0-mm diameters, all pairwise comparisons of induced primary SA were significant, following the order CQ-PRK > CQ-LASIK > KLEx (6.0 mm: 0.31 ± 0.16, 0.09 ± 0.13, and 0.03 ± 0.10 µm; 7.0 mm: 0.88 ± 0.34, 0.58 ± 0.32, and 0.22 ± 0.25 µm, respectively; all adjusted p < 0.05). The difference between CQ-LASIK and KLEx at 6.0 mm was small (0.06 µm; 95% CI 0.01 to 0.11), whereas the differences between CQ-PRK and the other two procedures were larger (0.22 and 0.28 µm at 6.0 mm; 0.30 and 0.66 µm at 7.0 mm) (Table 4). Induced total HOAs at the 6.0- and 7.0-mm diameters were significantly greater in the CQ-PRK group than in the CQ-LASIK and KLEx groups, whereas the CQ-LASIK and KLEx groups did not differ significantly from each other. Induced coma and trefoil did not differ significantly among the groups at any diameter (Table 4; Figure 3).
Table 4.
Surgically induced change (postoperative − preoperative) in corneal higher-order aberrations and asphericity by analysis diameter, with between-group comparisons.
Figure 3.
Surgically induced changes in corneal higher-order aberrations (µm) across 2.0- to 7.0-mm diameters. (a) Change in total coma. (b) Change in total trefoil. (c) Change in primary spherical aberration. (d) Change in total HOA RMS. Data are presented as mean ± standard deviation; changes were calculated as postoperative minus preoperative values. Intergroup comparisons were performed using generalized estimating equations with Bonferroni-adjusted pairwise comparisons. * Significant difference between CQ-LASIK and CQ-PRK (adjusted p < 0.05); † significant difference between CQ-PRK and KLEx (adjusted p < 0.05); ‡ significant difference between CQ-LASIK and KLEx (adjusted p < 0.05). CQ-LASIK, Custom-Q laser in situ keratomileusis; CQ-PRK, Custom-Q photorefractive keratectomy; KLEx, keratorefractive lenticule extraction; HOA, higher-order aberration; RMS, root mean square; SA, spherical aberration.
3.3. Diameter-Specific Changes in Corneal Asphericity (Q-Value)
In all three groups, the preoperatively negative (prolate) asphericity shifted in the positive (oblate) direction at all measured diameters after surgery (Table 2). The magnitude of the surgically induced Q-value change differed significantly among the groups in the order CQ-PRK > CQ-LASIK > KLEx at the 6.0- and 7.0-mm diameters (6.0 mm: 1.00 ± 0.52, 0.79 ± 0.08, and 0.57 ± 0.07; all pairwise adjusted p < 0.05; Table 4). At the 8.0-mm diameter, the same ordering was present, but the intergroup differences no longer reached significance (overall p = 0.059), and at the 9.0-mm diameter no differences were observed (Figure 4).
Figure 4.
Surgically induced changes in corneal Q-value across 6.0- to 9.0-mm diameters. Data are presented as mean ± standard deviation; changes were calculated as postoperative minus preoperative values. Intergroup comparisons were performed using generalized estimating equations with Bonferroni-adjusted pairwise comparisons. * Significant difference between CQ-LASIK and CQ-PRK (adjusted p < 0.05); † significant difference between CQ-PRK and KLEx (adjusted p < 0.05); ‡ significant difference between CQ-LASIK and KLEx (adjusted p < 0.05). CQ-LASIK, Custom-Q laser in situ keratomileusis; CQ-PRK, Custom-Q photorefractive keratectomy; KLEx, keratorefractive lenticule extraction.
3.4. Sensitivity Analysis
When the analysis was restricted to one randomly selected eye per patient (107 eyes), the results of the primary comparisons at the 6.0-mm diameter were unchanged in direction and significance: induced primary SA (adjusted p < 0.001 for CQ-PRK versus CQ-LASIK and versus KLEx; p = 0.042 for CQ-LASIK versus KLEx), induced total HOAs (CQ-PRK greater than CQ-LASIK and KLEx), and the Q-value change (CQ-PRK > CQ-LASIK > KLEx, all adjusted p < 0.05) showed the same pattern as in the all-eyes GEE analysis, whereas coma and trefoil did not differ among the groups (Supplementary Table S1). Adjustment for preoperative central corneal thickness, MRSE, and ablation depth did not change the direction or significance of any between-group difference at 6.0 mm.
4. Discussion
This study compared CQ-LASIK, CQ-PRK, and KLEx in a consecutive cohort operated on at a single center with the same 6.5-mm optical zone, analyzing refractive outcomes together with surgically induced changes in corneal HOAs and asphericity across multiple corneal diameters, using an analysis that accounted for the correlation between fellow eyes. Three findings emerged. First, all three procedures achieved comparably excellent and predictable refractive correction. Second, the induced HOA changes were indistinguishable among the procedures in the central cornea (2.0–4.0 mm); from 5.0 mm outward, induced primary SA—and consequently total HOAs—differed, being greatest after CQ-PRK and smallest after KLEx. Third, the oblate shift in corneal asphericity followed the same order at 6.0 and 7.0 mm, whereas induced coma and trefoil were similar across the procedures at every diameter.
The equivalence of refractive outcomes frames how the aberration findings should be read. UDVA of 20/20 or better was achieved in 95–96% of eyes, the MRSE was within ±1.0 D of the target in approximately 97% of eyes in every group, and no refractive or vector parameter differed among the groups. These results are consistent with previous pairwise comparisons of ablation- and lenticule-based procedures [8,9,10,11]. The Alpins analysis showed a correction index of 0.75–0.78 and a negative magnitude of error in all three groups, indicating a mild and comparable undercorrection of astigmatism irrespective of the procedure. Because the mean preoperative cylinder was low (approximately 1.5 D), the correction index is sensitive to small absolute residuals, and part of the apparent undercorrection may reflect the difference between refractive and corneal astigmatism and the measurement variability of low cylinders; the absence of intergroup differences, together with the comparable MRSE and UDVA outcomes, suggests that this undercorrection is attributable to the shared nomogram rather than to any particular technique. Because visual acuity and manifest refraction are governed mainly by lower-order aberrations, differences among contemporary procedures are more likely to be found in the induced HOAs, which is where the three procedures separated in the present study.
Within the central 4.0 mm, none of the procedures increased primary SA above preoperative values, and although coma and total HOAs increased modestly from 3.0 or 4.0 mm onward, these changes did not differ among the groups. When a sufficiently large optical zone is used, therefore, all three approaches preserved the optical quality of the central cornea, in line with reports that SA and Q-value changes after myopic laser correction are minimal centrally and rise toward the periphery [12]. For the excimer groups, this reflects the intended behavior of the Custom-Q profile, which aims to reproduce the preoperative asphericity across the treatment zone [5]; for KLEx, the lenticule geometry itself relatively preserves the anterior corneal profile [7,13]. Because the photopic entrance pupil is close to 3 mm, this region covers the pupil used for most daytime tasks, which is consistent with the equivalent visual acuity observed in all groups.
The procedures separated in the peripheral cornea, where induced primary SA was greatest after CQ-PRK and smallest after KLEx. Two mechanisms plausibly contribute. In excimer-based procedures, the laser beam strikes the peripheral cornea obliquely, reducing the effective fluence and causing relative peripheral under-ablation, a recognized source of induced SA [3]; this applies to both excimer groups but not to KLEx, in which the lenticule interfaces are photodisrupted at a programmed depth largely independent of surface obliquity. In addition, epithelial and stromal wound-healing responses are more pronounced after surface ablation, where epithelial hyperplasia and stromal remodeling preferentially fill the ablation periphery, whereas in LASIK the flap partly buffers this remodeling [2,6]. Two procedural factors specific to the CQ-PRK group may also have contributed: mitomycin C, which was applied in every PRK eye, modulates the stromal wound-healing response and thereby the final peripheral profile, and the epithelial debridement zone (8.0–9.0 mm) and the excimer transition zone differ geometrically from the lenticule side cut of CLEAR. These factors cannot be separated from the ablation profile in the present design. Consistent with these mechanisms, previous studies evaluating the effective optical zone (EOZ) have demonstrated that lenticule extraction preserves the achieved optical zone better than excimer ablation for a given programmed zone [14,15], and that a reduced EOZ directly correlates with greater SA induction [14,15]; because the EOZ was not measured in the present study, the diameter-specific SA profile served only as an indirect indicator of this behavior.
The asphericity data support this interpretation. The oblate Q-value shift followed the same order as induced SA at 6.0 and 7.0 mm; at 8.0 mm the gradient persisted but was no longer significant, and it disappeared at 9.0 mm, beyond the direct influence of the treatment zone. Because an oblate shift of the anterior corneal surface is the principal geometric driver of positive SA after myopic correction [3,4], the concordance of two independently measured parameters suggests a genuine, shape-based difference rather than measurement noise. In contrast, induced coma and trefoil were similar across the procedures at every diameter. These aberrations mainly reflect treatment decentration and cyclotorsional alignment rather than the radial ablation profile [14], so their equivalence suggests that centration and rotational control were comparably effective across the platforms. The composition of the total HOA change also varied with diameter: centrally, the increase was driven mainly by coma in all groups, whereas peripherally SA became a major contributor, particularly after CQ-PRK—which explains why total HOAs at 6.0 and 7.0 mm were greater after CQ-PRK while CQ-LASIK and KLEx remained similar.
It should be emphasized that CQ-LASIK and CQ-PRK were performed with the same excimer platform and the same Custom-Q algorithm, so that their comparison isolates the contribution of the flap and of the surface wound-healing response, whereas KLEx differed from both in laser platform, tissue-removal principle, and optical design. The three-way comparison therefore describes three treatment approaches as clinical packages rather than the effect of the ablation profile itself, and the smaller SA induction after KLEx cannot be attributed to any single element of that package.
Taken together, the three procedures are better described as having different corneal optical profiles than as being better or worse than one another. All three preserved the central cornea and corrected refraction equally well, and the differences that did emerge were confined to the peripheral cornea and were modest in absolute magnitude. KLEx induced the least peripheral SA and preserved a corneal shape closest to the physiological prolate profile. CQ-LASIK offered an intermediate peripheral profile together with the flexibility of customized excimer ablation and rapid visual rehabilitation. CQ-PRK induced the most peripheral SA in this cohort, but surface ablation retains well-established clinical advantages that this optical measure does not capture: it avoids flap-related complications and the lifelong possibility of traumatic flap dislocation, making it suitable for patients at occupational or recreational risk of ocular trauma [16]; it preserves more residual stromal bed for a given correction, which is one of the strongest determinants of post-refractive ectasia risk and makes surface ablation preferable in thinner corneas or borderline tomography [17]; and it remains the procedure of choice for correcting refractive error in eyes with epithelial basement membrane dystrophy or superficial corneal irregularity [18]. Because induced SA and the oblate shift increase with the attempted correction for a given optical zone, and the effective optical zone itself contracts as the correction increases [19,20,21], the peripheral differences may be somewhat more relevant in eyes with higher myopia.
These considerations pertain to corneal optical profiles only, and the clinical relevance of the observed differences should not be overstated. Increases in HOAs, particularly SA, have been associated with reduced contrast sensitivity and night-vision symptoms such as glare and halos [1,22]. In the present study, the between-group differences in induced primary SA at 6.0 mm ranged from 0.06 µm (CQ-LASIK versus KLEx) to 0.28 µm (CQ-PRK versus KLEx). For comparison, simulation studies indicate that approximately 0.25 µm RMS of a single Zernike mode over a 6-mm pupil is needed to reduce high-contrast visual acuity by about one line [23], and the mean total HOA RMS of normal eyes at 6 mm is approximately 0.3–0.4 µm [22]. The difference between CQ-LASIK and KLEx is therefore well below the range that is expected to be perceptible, whereas the larger difference between CQ-PRK and the other procedures approaches it and may become relevant in eyes with large scotopic pupils or high attempted corrections. Moreover, these values describe the anterior corneal surface at a fixed analysis diameter; the functional impact depends on the individual pupil size under mesopic conditions and on compensation by the internal optics. Whether the differences observed here translate into actual symptoms was not tested in the present study, which measured corneal optical parameters and did not assess pupil size, contrast sensitivity, night-vision symptoms, or patient satisfaction; readers should therefore regard the peripheral differences as statistically robust but of uncertain clinical significance. Corneal thickness, degree of refractive error, topographic regularity, dry eye status, lifestyle, and patient preference remain the principal determinants of procedure selection.
An important qualification concerns the generalizability of our KLEx results. The KLEx procedure evaluated here was exclusively CLEAR performed on the FEMTO LDV Z8 platform, a low-energy, high-frequency femtosecond laser. Lenticule geometry, side-cut and transition design, and laser energy settings differ among KLEx platforms, and aberration outcomes reported after small-incision lenticule extraction (SMILE) vary across studies [10,15,24]. The present findings should therefore be read as pertaining to CLEAR with the described settings and should not be extrapolated to SMILE or to other lenticule extraction procedures.
This study has several additional limitations. First, its retrospective, non-randomized design means that procedure assignment was influenced by clinical factors such as corneal thickness, occupation, and patient preference; although baseline refraction, keratometry, central corneal thickness, aberrations, ablation depth, and residual stromal bed thickness were comparable among the groups, residual confounding cannot be excluded. Second, the three procedures differ simultaneously in laser platform, treatment algorithm, treatment-zone geometry, adjunctive mitomycin C use, and wound-healing behavior, so the observed differences reflect each procedure as a clinical package and cannot be attributed to any single factor. Third, pupil size and subjective visual-quality measures were not assessed, and only anterior corneal (not whole-eye) aberrations were measured; because the internal optics partially compensate for corneal aberrations [13,25], the corneal HOA values reported here do not necessarily reflect the retinal image quality experienced by patients, and the present findings cannot be directly linked to subjective visual performance such as glare, halos, or night-vision quality. Fourth, both eyes of every patient were included. To address the resulting inter-eye correlation, all between-group analyses used GEE with the patient as the clustering unit, and a sensitivity analysis using one randomly selected eye per patient reproduced the primary findings; nevertheless, the large number of comparisons across parameters and diameters means that isolated borderline results, in particular the within-group comparisons that were not adjusted for multiplicity, should be interpreted with caution. Fifth, Scheimpflug measurements of the far-peripheral cornea (7.0–9.0 mm) may be less repeatable owing to tear-film and eyelid effects; a single device and standardized acquisition protocol were used to mitigate, but cannot eliminate, this variability. Sixth, the effective optical zone was not measured, so the mechanistic link between EOZ preservation and the smaller SA induction after KLEx remains inferential. Seventh, as noted above, the lenticule extraction group comprised solely eyes treated with the CLEAR procedure on a single low-energy platform; because lenticule geometry and energy parameters differ among KLEx platforms, these findings should not be generalized to all lenticule-based procedures. Eighth, the follow-up was limited to 6 months; epithelial and stromal remodeling, particularly after surface ablation, can continue beyond this period [6], so the conclusions apply to the 6-month time point and the peripheral profile of the CQ-PRK group in particular may change over time. Finally, the single-center, two-surgeon design strengthens internal standardization but may limit generalizability. Prospective studies incorporating pupillometry, whole-eye aberrometry, EOZ measurement, longer follow-up, and subjective visual-quality outcomes are warranted.
Finally, the CQ-LASIK and KLEx groups of the present cohort overlap with those of a separate analysis by our group that compared CQ-LASIK, topography-guided LASIK, and CLEAR from the perspective of the excimer treatment algorithm [26]. That study examined whether the choice of ablation profile within flap-based surgery alters outcomes relative to lenticule extraction, whereas the present study compares three categories of keratorefractive surgery and includes the CQ-PRK group, which was not part of the earlier report; the primary comparisons of the two studies therefore do not overlap.
5. Conclusions
In a consecutive cohort operated on with the same 6.5-mm optical zone, CQ-LASIK, CQ-PRK, and CLEAR-based KLEx all delivered excellent and statistically indistinguishable refractive and visual outcomes at 6 months, and none of them degraded the optical quality of the central 4.0-mm cornea. The procedures differed only in the peripheral cornea, where the induced primary SA and the oblate shift in asphericity at 6.0 and 7.0 mm were greatest after CQ-PRK and smallest after KLEx, while coma and trefoil were procedure-independent; these findings were robust to adjustment for inter-eye correlation. Rather than establishing the superiority of any single technique, these findings describe complementary corneal optical profiles that can be weighed alongside corneal thickness, refractive error, tomographic findings, ocular surface status, and patient preference. The differences were modest in absolute magnitude, were confined to the 6-month time point and to the CLEAR platform studied, and were not linked to symptoms in this study; prospective evaluation with pupillometry, whole-eye aberrometry, and subjective visual-quality measures is needed to determine their functional relevance.
Supplementary Materials
The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/jcm15239253/s1, Table S1: Sensitivity analysis of the primary comparisons at 6.0 mm using one randomly selected eye per patient; Table S2: Preoperative and postoperative corneal higher-order aberrations by analysis diameter.
Author Contributions
Conceptualization, J.K., S.-H.C. and S.C.; methodology, J.K.; investigation, J.K.; data curation, J.K., Y.C. and D.N.; formal analysis, J.K. and Y.C.; visualization, J.K.; resources, S.-H.C. and S.C.; supervision, S.-H.C. and S.C.; project administration, S.-H.C. and S.C.; writing—original draft preparation, J.K.; writing—review and editing, S.-H.C., S.C., Y.C. and D.N. All authors have read and agreed to the published version of the manuscript.
Funding
This research received no external funding.
Institutional Review Board Statement
The study was conducted in accordance with the Declaration of Helsinki and approved by the Institutional Review Board of First Samsung Eye Clinic (approval no. FSEC-202512-HRR001-01, approved on 1 December 2025).
Informed Consent Statement
Patient consent was waived owing to the retrospective nature of the study.
Data Availability Statement
The data presented in this study are available from the corresponding author upon reasonable request. The data are not publicly available owing to privacy restrictions.
Conflicts of Interest
The authors declare no conflicts of interest.
References
- Yamane, N.; Miyata, K.; Samejima, T.; Hiraoka, T.; Kiuchi, T.; Okamoto, F.; Hirohara, Y.; Mihashi, T.; Oshika, T. Ocular higher-order aberrations and contrast sensitivity after conventional laser in situ keratomileusis. Investig. Ophthalmol. Vis. Sci. 2004, 45, 3986–3990. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Oshika, T.; Klyce, S.D.; Applegate, R.A.; Howland, H.C.; El Danasoury, M.A. Comparison of corneal wavefront aberrations after photorefractive keratectomy and laser in situ keratomileusis. Am. J. Ophthalmol. 1999, 127, 1–7. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Yoon, G.; Macrae, S.; Williams, D.R.; Cox, I.G. Causes of spherical aberration induced by laser refractive surgery. J. Cataract Refract. Surg. 2005, 31, 127–135. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Anera, R.G.; Jiménez, J.R.; Jiménez del Barco, L.; Bermúdez, J.; Hita, E. Changes in corneal asphericity after laser in situ keratomileusis. J. Cataract Refract. Surg. 2003, 29, 762–768. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Mostafa, M.M.; Abdelmotaal, H.; Abdelazeem, K.; Goda, I.; Abdel-Radi, M. Q-value customized versus wavefront-optimized ablation in femtosecond laser-assisted LASIK for myopia and myopic astigmatism: A prospective contralateral comparative study. Eye Vis. 2022, 9, 43. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Huang, H.; Yang, J.; Bao, H.; Chen, S.; Xia, B.; Zou, J. Retrospective analysis of changes in the anterior corneal surface after Q value guided LASIK and LASEK in high myopic astigmatism for 3 years. BMC Ophthalmol. 2012, 12, 15. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Järvenpää, J.J. Q-value individualized CLEAR lenticule extraction preserves corneal asphericity and minimizes spherical aberration while maintaining optical zone predictability. Sci. Rep. 2025, 15, 30470. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Kim, J.; Choi, S.H.; Lim, D.H.; Yang, C.M.; Yoon, G.J.; Chung, T.Y. Topography-guided versus wavefront-optimized laser in situ keratomileusis for myopia: Surgical outcomes. J. Cataract Refract. Surg. 2019, 45, 959–965. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Kim, S.; Na, S.; Choi, S.; Choi, S.H. Comparison of outcomes after wavefront-optimized and topography-guided transepithelial photorefractive keratectomy. Korean J. Ophthalmol. 2024, 38, 275–283. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Moshirfar, M.; Omidvarnia, S.; Christensen, M.T.; Porter, K.B.; Theis, J.S.; Olson, N.M.; Stoakes, I.M.; Payne, C.J.; Hoopes, P.C. Comparative analysis of corneal higher-order aberrations after laser-assisted in situ keratomileusis, photorefractive keratectomy, and small incision lenticule extraction with correlations to change in myopic Q-value and spherical equivalent with and without astigmatism. J. Clin. Med. 2024, 13, 1906. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Lee, C.-Y.; Yang, S.-F.; Lian, I.-B.; Chen, H.-C.; Huang, J.-Y.; Chang, C.-K. The efficiency, predictability and safety between Custom-Q femtosecond laser in situ keratomileusis and second (VisuMax 800) generation keratorefractive lenticule extraction surgery. Diagnostics 2025, 15, 634. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Choi, S.H.; Won, Y.K.; Na, S.J.; Nam, D.; Lim, D.H. Limitations of and solutions to using 6 mm corneal spherical aberration and Q value after laser refractive surgery. Bioengineering 2024, 11, 190. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Li, X.; Wang, Y.; Dou, R. Aberration compensation between anterior and posterior corneal surfaces after small incision lenticule extraction and femtosecond laser-assisted laser in situ keratomileusis. Ophthalmic Physiol. Opt. 2015, 35, 540–551. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Lin, E.-T.; Tsai, T.-H.; Lin, W.-H.; Chen, N.-N.; Chang, P.-C.; Sun, C.-C. Correlation between effective optical zone and higher-order aberrations in keratorefractive lenticule extraction and wavefront-guided laser in situ keratomileusis. Sci. Rep. 2026, 16, 529. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Moshirfar, M.; Herron, M.S.; Cha, D.S.; Santos, J.; Payne, C.J.; Hoopes, P.C. Comparing effective optical zones after myopic ablation between LASIK, PRK, and SMILE with correlation to higher order aberrations. J. Refract. Surg. 2023, 39, 741–750. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Xiao, J.H.; Jiang, C.H.; Zhang, M.N.; Jiang, H.; Li, S.Y.; Zhang, Y. When case report became case series: 45 cases of late traumatic flap complications after laser-assisted in situ keratomileusis and review of Chinese literature. Br. J. Ophthalmol. 2014, 98, 1282–1286. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Randleman, J.B.; Woodward, M.; Lynn, M.J.; Stulting, R.D. Risk assessment for ectasia after corneal refractive surgery. Ophthalmology 2008, 115, 37–50. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Woreta, F.A.; Davis, G.W.; Bower, K.S. LASIK and surface ablation in corneal dystrophies. Surv. Ophthalmol. 2015, 60, 115–122. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Al-Mohaimeed, M.M. Effect of the optical zone ablation diameter on higher order aberrations after transepithelial photorefractive keratectomy: A cohort study. Cureus 2021, 13, e17630. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Zeng, J.; Lan, G.; Zhu, M.; Sun, K.; Shi, Q.; Ma, G.; Liu, Q. Factors associated with corneal high-order aberrations before and after femtosecond laser-assisted in situ keratomileusis. Ann. Transl. Med. 2021, 9, 989. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Moshirfar, M.; Herron, M.S.; Cha, D.S.; Santos, J.M.; Miller, L.T.; Sr, P.C.H. Correlational analysis of the effective optical zone with myopia, myopic astigmatism, and spherical equivalent in LASIK, PRK, and SMILE. Clin. Ophthalmol. 2024, 18, 377–392. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Oshika, T.; Okamoto, C.; Samejima, T.; Tokunaga, T.; Miyata, K. Contrast sensitivity function and ocular higher-order wavefront aberrations in normal human eyes. Ophthalmology 2006, 113, 1807–1812. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Applegate, R.A.; Marsack, J.D.; Ramos, R.; Sarver, E.J. Interaction between aberrations to improve or reduce visual performance. J. Cataract Refract. Surg. 2003, 29, 1487–1495. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Aljaberi, H.A.; Rahmani, S.; Alrikabi, H.H. Comparative clinical outcomes of SMILE, femtosecond LASIK, and transepithelial PRK: A multicenter Iraqi study. Front. Ophthalmol. 2026, 6, 1787176. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Artal, P.; Guirao, A.; Berrio, E.; Williams, D.R. Compensation of corneal aberrations by the internal optics in the human eye. J. Vis. 2001, 1, 1–8. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Ko, J.; Choi, S.-H.; Choi, Y.; Choi, S. Comparison of outcomes after Custom-Q laser in situ keratomileusis, topography-guided laser in situ keratomileusis, and lenticule extraction. Korean J. Ophthalmol. 2026; in press. [CrossRef] [Scilit] [PubMed]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.



