Reviewer 1 Report
Comments and Suggestions for AuthorsThe study presents an original and interesting concept. However, the presentation and discussion of the results are rather general and lack sufficient depth. The findings should be discussed more comprehensively by comparing them with relevant studies reported in the literature and by providing a more critical interpretation of the observed trends. The inclusion of the modeling component is a notable strength of the study. Nevertheless, this section would benefit from a more detailed discussion, including a deeper interpretation of the modeling results, their relationship to the experimental findings, and their significance within the context of the study.
i) The Introduction is rather limited and written in a general manner. It should be strengthened by incorporating previous electrodialysis (ED) studies focusing on the separation of taurine and Na₂SO₄. The pioneering studies in the literature addressing this separation should be discussed in greater detail, and the advantages of ED for this application should be more clearly highlighted. Furthermore, the limitations and knowledge gaps of the existing ED studies should be explicitly identified. The Introduction should clearly state the hypothesis, novelty, and scientific contribution of the present work by emphasizing which specific gap in the literature this study aims to address. As currently written, the study appears to focus mainly on process optimization and parametric analysis, which weakens the perception of its originality and scientific significance.
ii) Although the cost and shelf life of the membranes are known, their commercial name has not been provided in the manuscript. The commercial name, manufacturer, and detailed specifications of the membranes should be clearly stated. In addition, the properties of the spacers, such as their porosity (open area ratio) and other relevant specifications, should also be included to ensure that the experimental setup can be properly evaluated and reproduced.
iii) Figure 1 does not adequately illustrate the working principle of the proposed system and should be reorganized to provide a clearer representation of the process.
In addition, the rationale for using pure water in the concentrate compartment should be clearly explained. The use of pure water is expected to increase the electrical resistance of the system, which may adversely affect the process performance. In contrast, the LCD study has employed the same solution in both the dilute and concentrate compartments.
iv) Page 6, Line 162, "recovery" is written twice. Equations 3,6,7,8,9 need referances.
v) The interpretation of the temperature values presented in Table 3 appears to be somewhat overstated. Considering the potential experimental uncertainty and the likely presence of standard deviations in the measurements, the observed differences may not be sufficiently significant to support the conclusions drawn. The authors are encouraged to assess the statistical significance of these differences and revise the discussion accordingly.
vi) Section 3.4 does not appear to provide sufficient standalone value in its current form. It is recommended that this section be removed and its relevant content be integrated into Section 3.5 to improve the overall flow and organization of the manuscript.
vii) Although the highest taurine purification was achieved at a flow rate of 200 L/h in the flow rate optimization experiments, the feed concentration experiments were subsequently conducted at 150 L/h. The rationale for selecting this operating condition is not sufficiently explained. It appears that a systematic approach was not followed in determining the optimum flow rate. The authors should clearly justify the selection of the operating conditions used in the subsequent experiments and explain why the condition yielding the highest purification performance was not adopted.
Author Response
|
Response to Reviewer 1 Comments
|
||
|
Summary |
|
|
|
Thank you for your thorough review and valuable comments on our manuscript entitled "Separation of Taurine and Sodium Sulfate from Simulated Mother Liquor by Electrodialysis and Process Optimization". Your constructive suggestions have been of great help in improving the quality of our work. We have carefully considered all the comments and have addressed each of them point‑by‑point in the response letter below. All revisions made in the manuscript have been highlighted in red for easy identification. The corresponding locations (page numbers and line numbers) of each modification are also provided in our responses. We believe that the revised manuscript has been substantially improved in terms of academic depth and experimental design. We are grateful for your time and expertise in reviewing our work. Should you have any further questions, please do not hesitate to contact us. |
||
|
Point-by-point response to Comments and Suggestions for Authors |
||
|
Comments 1:The Introduction is rather limited and written in a general manner. It should be strengthened by incorporating previous electrodialysis (ED) studies focusing on the separation of taurine and Na2SO4. The pioneering studies in the literature addressing this separation should be discussed in greater detail, and the advantages of ED for this application should be more clearly highlighted. Furthermore, the limitations and knowledge gaps of the existing ED studies should be explicitly identified. The Introduction should clearly state the hypothesis, novelty, and scientific contribution of the present work by emphasizing which specific gap in the literature this study aims to address. As currently written, the study appears to focus mainly on process optimization and parametric analysis, which weakens the perception of its originality and scientific significance. |
||
|
Response 1: We agree with this comment. The changes are highlighted on lines 68-854.We have deepened the analysis of previous studies and identified the research gaps, thereby emphasizing the value of our work. “ED may therefore reduce the number of phase-change steps required in conventional crystallization, thereby lowering the separation energy and improving taurine recovery. Early studies on ED separation of taurine from Na2SO4 demonstrated the technical feasibility of this approach. Konarev reported that introducing ED into taurine production markedly improved product quality, eliminated energy-intensive operations, and removed poisonous gas emissions [15]. In an early investigation, Zhao et al. achieved a taurine purity of 98.5% and a recovery of 78.1% from a taurine/Na2SO4 mixed solution using ED [16]. More recently, Eliseeva and Kharina comprehensively reviewed electromembrane desalination of amino acid solutions, examining the influence of various mineral cations (Na+, K+, NH4+) and anions (NO3-, SO42-, Cl-) on ion transport and membrane current-voltage characteristics [17]. Studies on phenylalanine-salt systems have further revealed that electroconvection at overlimiting current modes can increase amino acid loss, and that membrane ion-exchange resin content significantly affects separation efficiency [18]. For the taurine/Na2SO4 system, the effects of operating parameters on amino acid loss and mass-transfer behavior under high salt concentrations remain insufficiently understood. Endpoint regulation of the ED process coupled with crystallization for energy consumption control has not been reported, and the specific advantages of ED over crystallization have not been quantitatively evaluated. In this study, conventional ED was used to desalt a binary simulated taurine/Na2SO4 mother liquor. ” |
||
|
Comments 2: Although the cost and shelf life of the membranes are known, their commercial name has not been provided in the manuscript. The commercial name, manufacturer, and detailed specifications of the membranes should be clearly stated. In addition, the properties of the spacers, such as their porosity (open area ratio) and other relevant specifications, should also be included to ensure that the experimental setup can be properly evaluated and reproduced. |
||
|
Response 2: We thank the reviewer for this careful and constructive comment. The supplier of the SED‑30 unit, Shanghai Sanji New Material Co., Ltd. (Shanghai, China), is also the manufacturer of both types of membranes. We have obtained further information on the membranes from the supplier and supplemented the dimensions of the membranes and spacers in Table 1 (line 112). Unfortunately, we do not have information on the spacer porosity; however, we have added a description of the spacer geometry in the revised manuscript at lines 103-112. “The spacer used in the stack is of a square‑mesh support type with a grid size of 1 cm×1 cm and a filament width of 1 mm. The electrode material is Ti/Pt (titanium‑coated platinum). ” |
||
|
Comments 3: Figure 1 does not adequately illustrate the working principle of the proposed system and should be reorganized to provide a clearer representation of the process. |
||
|
Response 3: Agree. In response to this comment, we have removed the confusing water‑chamber configuration from Figure 1. The part illustrating the separation principle has been retained and further optimized to make the key aspects of the process more clearly visible. Deionized water was placed in the concentrate compartment to provide a salt-free baseline, allowing the salt flux to be directly determined from the increase in concentrate conductivity. Although this raised the initial electrical resistance, the concentrate conductivity increased rapidly as salt migrated, so the adverse effect was limited to the early stage. In our study, using deionized water in the concentrate compartment also helped to analyze the effect of the concentrate salt concentration on desalination performance. We have added a clarification regarding the use of deionized water in the concentrate compartment at the initial stage (lines 119-126). “ Deionized water was used in the concentrate compartment at the beginning of each batch experiment. Although this practice inevitably increased the initial electrical resistance of the stack and may have temporarily reduced the current efficiency, it was adopted to establish a well-defined initial state with zero background salt concentration. This allowed the salt flux across the membranes to be quantified directly from conductivity changes in the concentrate stream. Figure 1 schematically shows the separation principle of taurine and Na2SO4 by electrodialysis. ” In addition, we have pointed out the influence of the initial conductivity of the concentrate compartment as practical advice for readers in the revised manuscript, which can be found at lines 454-456: “For continuous operation, the salt concentration in the concentrate compartment should be maintained at a level corresponding to a conductivity above 15 mS/cm to avoid excessive resistance and low current efficiency.” In the LCD measurement, however, identical concentrations were used in both compartments to maintain a steady concentration field, which is necessary for the correct determination of the limiting current density. It should be noted that during the actual desalination runs, the solution concentration in the dilute compartment decreases continuously over time, and as a result, the actual limiting current density also changes dynamically throughout the run. In the low‑concentration stage toward the end of the process, the LCD becomes considerably lower than the value measured under constant‑concentration conditions, meaning that even if the current density appears moderate in absolute terms, concentration polarization may still occur. Conversely, in the high‑concentration stage at the beginning of the run, a relatively high current density may remain below the actual LCD because the high bulk concentration can sustain rapid ion replenishment to the membrane surface. Therefore, the LCD measurement serves as a practical guide for voltage selection rather than a fixed threshold that applies uniformly throughout the entire desalination process. The dynamic nature of the limiting current density under varying concentration conditions is acknowledged in the revised discussion (Section 2.3, lines 153–162), and the current‑density profiles presented in the new Figure 5d should be interpreted with this dynamic behavior in mind. “The ilim measured under constant-concentration conditions provides a practical reference for selecting the applied voltage, rather than a fixed threshold that applies uniformly throughout the entire batch desalination process. In actual operation, the dilute‑compartment concentration decreases continuously, and the ilim varies accordingly. Therefore, a current density that exceeds the measured ilim under steady‑state conditions may not necessarily cause concentration polarization when the bulk concentration is high, while a current density below the measured ilim may still cause polarization when the salt concentration becomes low. The actual current‑density evolution during each run is therefore the more relevant indicator for assessing polarization.” |
||
|
Comments 4: Page 6, Line 162, "recovery" is written twice. Equations 3,6,7,8,9 need referances. |
||
|
Response 4: Thank the reviewer for this comment. The duplicate word has been deleted, and references for Equations (6), (7), and (8) have been added on line 196. Equation (3) is an empirical correlation fitted from the conductivity measured by our equipment and the Na₂SO₄ concentrations determined by ICP-MS; it is applicable to our experimental system. Equation (9) is the formula used to estimate the membrane replacement cost under the specific assumptions of this study. |
||
|
Comments 5: v) The interpretation of the temperature values presented in Table 3 appears to be somewhat overstated. Considering the potential experimental uncertainty and the likely presence of standard deviations in the measurements, the observed differences may not be sufficiently significant to support the conclusions drawn. The authors are encouraged to assess the statistical significance of these differences and revise the discussion accordingly. |
||
|
Response 5: We thank the reviewer for this suggestion. Statistical analysis confirmed that the temperature differences were not significant. Accordingly, we have revised the interpretation of the temperature data. The energy consumption increase is now attributed to more fundamental causes (concentration polarization and decreased current efficiency), with the temperature rise presented only as minor supporting evidence. The revisions are located on lines 329-358. “This trend is likely associated with Joule heating: higher currents generate more resistive heat in the membranes and solution, thereby reducing current efficiency. The solution temperature increased slightly with increasing applied voltage (Table 3). The observed temperature rise ranged from 0.3 °C (at 8 V) to 1.4 °C (at 16 V), consistent with the expected Joule heating effect. However, given the small magnitude of these changes and the fact that all temperatures remained well below the membrane manufacturer’s recommended limit (40 °C), the thermal effect is unlikely to have significantly influenced membrane performance or separation efficiency under the tested conditions. A paired t-test between the 8 V and 16 V groups gave p > 0.05, indicating that the temperature differences observed across the voltage range were not statistically significant at the 95% confidence level. This suggests that the thermal effect was minor under the present operating conditions. Therefore, the decline in current efficiency can also be attributed to other factors. Although the current increased with applied voltage, the current efficiency decreased slightly at higher voltages because a larger fraction of the applied current may be consumed by water dissociation and counter-ion transport rather than by Na2SO4 removal. Second, the higher current density at elevated voltages may have promoted concentration polarization near the membrane surfaces, increasing the membrane resistance and thus the energy required per unit of salt removed. Joule heating was a minor side-effect rather than a primary contributor to the observed increase in energy consumption. The dominant factor governing the voltage-dependence of energy consumption was therefore the trade-off between increased driving force and reduced current efficiency.” |
||
|
Comments 6: Section 3.4 does not appear to provide sufficient standalone value in its current form. It is recommended that this section be removed and its relevant content be integrated into Section 3.5 to improve the overall flow and organization of the manuscript. |
||
|
Response 6: Agree. The original Section 3.4 has been deleted, and its content has been merged into the original Section 3.5, which is now renumbered as Section 3.4.The changes are highlighted on lines 445-450. |
||
|
Comments 7: Although the highest taurine purification was achieved at a flow rate of 200 L/h in the flow rate optimization experiments, the feed concentration experiments were subsequently conducted at 150 L/h. The rationale for selecting this operating condition is not sufficiently explained. It appears that a systematic approach was not followed in determining the optimum flow rate. The authors should clearly justify the selection of the operating conditions used in the subsequent experiments and explain why the condition yielding the highest purification performance was not adopted. |
||
|
Response 7: Thank you for this important observation. The selection of 150 L/h for the concentration-dependence experiments was intended to maintain a consistent hydrodynamic environment while varying only the feed concentration. At the time the concentration experiments were conducted, the flow-rate optimization had not yet been completed. Since the voltage optimization experiments had been performed at 150 L/h, we chose the same flow rate for the concentration experiments to ensure comparability and to keep the number of variables to a minimum. We acknowledge that, in an ideal experimental design, the concentration experiments should have been repeated at the optimal flow rate of 200 L/h after the flow-rate optimization was finalized. However, due to time and sample availability constraints, this was not pursued in the present study. We have now added a note in the revised manuscript (Section 3.3,lines 405-408) indicating that the concentration effects were evaluated at 150 L/h and that future studies should verify the trends at the optimal flow rate of 200 L/h. Despite this limitation, we believe the observed concentration-dependent trends remain valid, as the relative changes across different initial salt concentrations are consistent within the same hydrodynamic framework. “ The concentration-dependence experiments were conducted at a circulation flow rate of 150 L/h, which was the same condition used in the voltage optimization experiments to maintain a consistent hydrodynamic baseline.” |
||
Author Response File:
Author Response.pdf
Reviewer 2 Report
Comments and Suggestions for AuthorsThis manuscript investigates the separation of taurine and sodium sulfate from a simulated mother liquor using electrodialysis (ED). The authors systematically evaluate the effects of operating voltage, circulation flow rate, and feed concentration on desalination performance and complement the experimental work with COMSOL simulations to explain ion transport behavior. In addition, the manuscript proposes an endpoint-control strategy to reduce energy consumption and compares the ED process with the conventional crystallization route.
Overall, the manuscript is well organized, technically sound, and addresses an industrially relevant separation problem. The experiments are generally systematic, and the obtained taurine purity (99.8%) and recovery (98.9%) demonstrate the potential of electrodialysis for this application. The integration of experimental observations with numerical simulation improves the mechanistic understanding of the process.
However, several issues should be addressed before publication. Most of the concerns relate to the practical applicability of the proposed process, validation of the numerical model, and clarification of several methodological aspects. Therefore, I recommend Minor Revision.
My Comments
- Practical significance should be better emphasized.
The entire study is performed using a binary simulated taurine/Na₂SO₄ solution, whereas industrial mother liquor usually contains numerous impurities such as sodium isethionate, sodium iminodisulfonate, and other organic/inorganic species. These impurities can significantly influence membrane selectivity, fouling, osmotic transport, and long-term performance.
Although this limitation is acknowledged in the Discussion, the manuscript would benefit from a more comprehensive discussion of how these additional components may affect the proposed process and what challenges remain before industrial implementation.
- COMSOL model requires stronger validation.
The COMSOL simulations are mainly used to explain the experimental observations qualitatively. However, quantitative validation between simulation and experimental results is rather limited.
The authors should provide additional evidence demonstrating that the model accurately predicts experimental behavior. For example,
- comparison between simulated and experimental ion flux,
- conductivity evolution,
- concentration profiles,
- or current density under representative operating conditions.
Without stronger validation, the simulation should be presented primarily as a qualitative interpretation tool.
- Long-term membrane stability is not investigated.
The manuscript focuses on short laboratory experiments. However, membrane durability is one of the key issues for industrial ED applications.
The authors should discuss:
- possible membrane fouling,
- scaling,
- membrane cleaning,
- membrane lifetime under taurine production conditions,
- and the influence of prolonged operation on process economics.
Even if long-term experiments are beyond the scope of the present work, these limitations should be discussed more explicitly.
- Economic analysis contains several assumptions.
The cost comparison with conventional crystallization is interesting but depends heavily on assumptions regarding:
- electricity price,
- steam cost,
- membrane lifetime,
- annual operating hours,
- membrane price,
- and production capacity.
A brief sensitivity analysis (or at least a discussion of the uncertainty associated with these assumptions) would significantly strengthen the economic evaluation.
Minor Comments
- The keyword list contains a duplicate entry ("desalination").
- Section 2.1 is titled "Materials and Equipments." The correct title is:
Materials and Equipment
- The authors should report the effective membrane area explicitly in Table 1 rather than only using it later in Equation (8).
- The operating temperature remained below 40 °C throughout the experiments. Since temperature influences membrane conductivity and ion mobility, a short discussion of temperature effects would improve the manuscript.
- The manuscript reports that each experiment was performed in triplicate. It would be useful to include error bars or standard deviations in the figures wherever applicable.
- Some grammatical errors and typographical inconsistencies remain throughout the manuscript. Examples include:
- "Date Analysis" should be Data Analysis.
- "Recovery recovery" should be corrected.
- "Out put" should be Output.
- Several spacing and capitalization inconsistencies appear throughout the manuscript.
A careful language editing is recommended before publication.
- The manuscript would benefit from reporting the current density in addition to the applied voltage, as current density allows easier comparison with previous ED studies.
- The comparison with previous literature could be strengthened by including a concise table summarizing:
- feed composition,
- operating conditions,
- recovery,
- purity,
- energy consumption,
- and membrane productivity
for comparable electrodialysis studies involving amino acid or organic acid separations.
- The endpoint optimization strategy proposed in Section 3.5 is one of the most interesting outcomes of the study. The authors may consider emphasizing this novelty more strongly in both the Abstract and Conclusions.
- Some figure labels, axis fonts, and legends appear relatively small and may be difficult to read after journal formatting. Improving figure readability would enhance presentation quality.
This manuscript presents a systematic investigation of electrodialytic separation of taurine from sodium sulfate and provides useful experimental data supported by numerical simulation. The proposed endpoint-control strategy for reducing energy consumption is particularly valuable and represents a practical contribution to process optimization.
The manuscript is suitable for publication in Membranes after minor revision addressing the comments listed above, particularly those concerning model validation, discussion of industrial applicability, and clarification of methodological details.
Author Response
|
Response to Reviewer 2 Comments
|
||||||||||||||||||||||||||||||||||||||||||||
|
Summary |
|
|
||||||||||||||||||||||||||||||||||||||||||
|
We sincerely appreciate your positive recognition of our work, which has been a great encouragement to us. We have also attached great importance to the suggestions and comments you raised, and have revised and responded to each of them accordingly. The revisions are marked in red in the revised manuscript, and the corresponding line numbers are provided for your convenience. |
||||||||||||||||||||||||||||||||||||||||||||
|
Point-by-point response to Comments and Suggestions for Authors |
||||||||||||||||||||||||||||||||||||||||||||
|
Comments 1:The entire study is performed using a binary simulated taurine/Na₂SO₄ solution, whereas industrial mother liquor usually contains numerous impurities such as sodium isethionate, sodium iminodisulfonate, and other organic/inorganic species. These impurities can significantly influence membrane selectivity, fouling, osmotic transport, and long-term performance. Although this limitation is acknowledged in the Discussion, the manuscript would benefit from a more comprehensive discussion of how these additional components may affect the proposed process and what challenges remain before industrial implementation. |
||||||||||||||||||||||||||||||||||||||||||||
|
Response 1: Thanks for your comment. We fully agree that industrial taurine mother liquor contains multiple impurities that may affect membrane performance, and we acknowledge that this is a key limitation of the present study. In response to this comment, we have substantially expanded the discussion in Section 3.5 (now renumbered as Section 3.4) to more comprehensively address the potential impact of impurities and the challenges for industrial implementation. Specifically, we have added a detailed discussion at line 479-493: ”The present study was conducted with a binary simulated system. Industrial taurine mother liquor typically contains additional impurities such as sodium isethionate, sodium iminodisulfonate, ethylene glycol, and polyethylene glycol [32]. These impurities may affect the ED process through several mechanisms. First, studies on amino acid electrodialysis have shown that prolonged contact between ion-exchange membranes and organic solutes can lead to structural changes in the membrane material and irreversible performance decay [33]. Second, the presence of additional ionic species (sodium iminodisulfonate) may compete with Na+ and SO42- for transport through the membranes, potentially reducing the selectivity for salt removal and increasing taurine loss. Third, the accumulation of non-volatile impurities in the recycled mother liquor during closed-loop operation may require additional purification steps to maintain process stability. Therefore, before industrial implementation, the long-term stability of membrane performance, effective cleaning protocols, and impurity accumulation management must be further investigated using real mother liquor or impurity-spiked simulated solutions [34]. ” |
||||||||||||||||||||||||||||||||||||||||||||
|
Comments 2: COMSOL model requires stronger validation. The COMSOL simulations are mainly used to explain the experimental observations qualitatively. However, quantitative validation between simulation and experimental results is rather limited. The authors should provide additional evidence demonstrating that the model accurately predicts experimental behavior. For example, • comparison between simulated and experimental ion flux, • conductivity evolution, • concentration profiles, • or current density under representative operating conditions. Without stronger validation, the simulation should be presented primarily as a qualitative interpretation tool.
|
||||||||||||||||||||||||||||||||||||||||||||
|
Response 2: We thank the reviewer for this important comment. The COMSOL model presented in our original submission lacks rigorous quantitative validation against experimental data. We would like to clarify, however, that the model was not intended to serve as a predictive tool for accurate performance simulation. Given that our group specializes in experimental membrane separation rather than numerical modeling, the model was developed primarily as a visual aid to help interpret the experimental trends and to illustrate the ion-transport behavior predicted by the Nernst–Planck framework. We recognize that without quantitative validation, the model’s utility is limited to qualitative interpretation. In response to this comment, we have revised the manuscript to clearly state that the modeling results are used solely for qualitative interpretation rather than for quantitative prediction. Specifically, we have: (1)Revised the description in Section 2.4 to state that the model serves as a qualitative tool for visualizing ion-transport behavior. Lines 212-219 “The COMSOL model presented here was developed as a qualitative interpretation tool to visualize the ion-transport behavior predicted by the Nernst–Planck equations under different operating conditions. The model has not been quantitatively validated against experimental data, and its outputs are intended to illustrate the trends observed in the experiments rather than to provide accurate quantitative predictions. Quantitative validation would require detailed inputs such as membrane transport properties, boundary-layer thickness, and concentration-dependent diffusion coefficients which are beyond the scope of the present study.” (2)Revised the discussion in Sections 3.1 and 3.3 to present the simulated flux profiles as qualitative illustrations of the trends observed experimentally, rather than as validated predictions. Lines 279-287: “The simulated Na+ flux profiles in Figure 6 are presented as qualitative illustrations of the effect of applied voltage on ion transport. The nearly flat regions at 0.0004 and 0.0014 m correspond to the ion-exchange membranes, whereas the regions with changing slopes on either side represent the membrane/solution boundary layers. While the simulations show a clear increase in Na+ flux with increasing unit voltage (from 1 to 3 V), consistent with the experimental desalination trends, the absolute flux values should not be interpreted as validated predictions due to the simplified nature of the model and the lack of quantitative calibration against the present experimental system. ” Lines 415-419: “The simulation results indicated that the desalination rate increased with initial concentration. As with the voltage simulations, the transient desalination profiles shown in Figure 11 are intended for qualitative interpretation of the concentration effect trends and have not been quantitatively validated against the present experimental data. ” (3) Added a clear statement in the concluding paragraph of the modeling section acknowledging the lack of quantitative validation and suggesting that future work with refined model parameters could pursue quantitative validation if needed. We believe these revisions appropriately position the model for its intended purpose and make its limitations transparent to readers. Lines 562-568: “Finally, it is acknowledged that the COMSOL model presented in this study has not been quantitatively validated against experimental data. The model is intended as a qualitative tool to support the interpretation of experimental trends rather than as a predictive simulation. Future studies with more comprehensive model parameters and systematic experimental validation could extend the quantitative capabilities of the modeling approach.” |
||||||||||||||||||||||||||||||||||||||||||||
|
Comments 3: Long-term membrane stability is not investigated. The manuscript focuses on short laboratory experiments. However, membrane durability is one of the key issues for industrial ED applications. The authors should discuss: • possible membrane fouling, • scaling, • membrane cleaning, • membrane lifetime under taurine production conditions, • and the influence of prolonged operation on process economics. Even if long-term experiments are beyond the scope of the present work, these limitations should be discussed more explicitly. |
||||||||||||||||||||||||||||||||||||||||||||
|
Response 3: Thanks for your comment. We fully agree that membrane durability is a critical issue for industrial ED applications, and we acknowledge that long-term stability was not investigated in this study. Due to the increased length of the revised manuscript, we have chosen to discuss this part briefly. A detailed discussion of membrane fouling has been included in our response to Comment 1. To avoid shifting the focus of the manuscript toward long-term effects that were not experimentally validated in this study, we have placed the discussion of scaling, cleaning, and membrane lifetime as limitations and future research directions in the Conclusions section. Should the reviewer feel that this treatment remains insufficient, we would be happy to make further revisions. Lines 558-562: “In industrial taurine mother liquor, organic impurities and inorganic scaling may cause membrane fouling. Although various cleaning strategies exist, complete restoration of membrane performance is often difficult. Membrane lifetime under such conditions remains unknown and requires long-term pilot studies.” |
||||||||||||||||||||||||||||||||||||||||||||
|
Comments 4: The cost comparison with conventional crystallization is interesting but depends heavily on assumptions regarding: • electricity price, • steam cost, • membrane lifetime, • annual operating hours, • membrane price, • and production capacity. A brief sensitivity analysis (or at least a discussion of the uncertainty associated with these assumptions) would significantly strengthen the economic evaluation. |
||||||||||||||||||||||||||||||||||||||||||||
|
Response 4 : We sincerely thank the reviewer for this constructive comment, which has been very helpful in improving our work. In response, we have performed a sensitivity analysis on the key economic parameters and incorporated the results into the revised manuscript. The relevant modifications are located on lines 522-533. “To assess the robustness of the economic evaluation, a simple sensitivity analysis was performed on the key assumptions listed above (Table 6). Each parameter was varied individually within a reasonable range while keeping all others at their baseline values, and the resulting change in the estimated separation cost was recorded. Table 6. Sensitivity analysis of key economic parameters on the estimated ED separation cost.
As summarized in Table 6, the separation cost is most sensitive to steam price and membrane lifetime: increasing the steam price increases the cost by 25%, while reducing the membrane lifetime from 5 to 3 years increases the cost by 8.3% . In contrast, the ED separation cost is relatively insensitive to electricity price membrane price and annual operating hours have a moderate impact (+2.1%). Within the selected variation ranges, the ED separation cost remained consistently lower than that of conventional crystallization.” |
||||||||||||||||||||||||||||||||||||||||||||
|
Comments 5: The keyword list contains a duplicate entry ("desalination"). Section 2.1 is titled "Materials and Equipments." The correct title is: Materials and Equipment Some grammatical errors and typographical inconsistencies remain throughout the manuscript. Examples include: • "Date Analysis" should be Data Analysis. • "Recovery recovery" should be corrected. • "Out put" should be Output. • Several spacing and capitalization inconsistencies appear throughout the manuscript. A careful language editing is recommended before publication. |
||||||||||||||||||||||||||||||||||||||||||||
|
Response 5: We are grateful to the reviewer for these corrections. The repeated word has been removed, and all spelling errors, capitalization inconsistencies, and spacing issues have been systematically addressed throughout the manuscript. We have carefully re-examined the entire text and trust that the revised version is now clearer and more readable. |
||||||||||||||||||||||||||||||||||||||||||||
|
Comments 6: The authors should report the effective membrane area explicitly in Table 1 rather than only using it later in Equation (8). |
||||||||||||||||||||||||||||||||||||||||||||
|
Response 6: Agree. We have added the membrane area parameter to Table 1 (line 112) to provide readers with a clearer reference. |
||||||||||||||||||||||||||||||||||||||||||||
|
Comments 7: The operating temperature remained below 40 °C throughout the experiments. Since temperature influences membrane conductivity and ion mobility, a short discussion of temperature effects would improve the manuscript. |
||||||||||||||||||||||||||||||||||||||||||||
|
Response 7: Thanks for this comment. We have added a short discussion on the effect of temperature on membrane conductivity and ion mobility in Section 3.1 (lines 352-357). “In electrodialysis, temperature influences both membrane conductivity and ion mobility [28]. Higher temperatures generally increase ionic diffusivity and reduce solution viscosity, which can enhance ion transport across the membrane and improve current efficiency. However, as shown in Table 3, the solution temperature in all experiments remained below 40 °C, which is within the safe operating range specified by the membrane manufacturer. ” |
||||||||||||||||||||||||||||||||||||||||||||
|
Comments 8: The manuscript reports that each experiment was performed in triplicate. It would be useful to include error bars or standard deviations in the figures wherever applicable. |
||||||||||||||||||||||||||||||||||||||||||||
|
Response 8: We thank the reviewer for this comment. In the original manuscript we had already stated that the desalination rates (conductivity curves) are reported as medians, while the recovery, purity, energy consumption, and membrane productivity values are reported as means. The figures presenting mean values have been updated with error bars. In response to this comment, we have now added a brief explanation for using medians for the desalination rate data and have bolded the error bars in the relevant figures to make them more visible. The corresponding revisions can be found on lines 139-144 of the revised manuscript. “The desalination rate is reported as the median value of triplicate runs because the conductivity readings exhibited relatively large fluctuations toward the end of the experiments, particularly when the salt concentration became low, and the use of the mean would have introduced bias due to these endpoint deviations. The median, being less sensitive to extreme fluctuations, provides a more representative description of the desalination trend.” |
||||||||||||||||||||||||||||||||||||||||||||
|
Comments 9: The manuscript would benefit from reporting the current density in addition to the applied voltage, as current density allows easier comparison with previous ED studies. |
||||||||||||||||||||||||||||||||||||||||||||
|
Response 9: Thanks for your comment. We fully acknowledge this limitation. At the initial stage of the experimental design, we opted for constant-voltage operation rather than constant-current operation on the recommendation of the equipment supplier. As the study progressed, we realized that this choice is somewhat unconventional compared with most previous electrodialysis studies, which typically adopt constant-current operation and present performance data as a function of current density. As a result, under constant-voltage operation, the current density variation followed a parabolic trend rather than the stepwise discrete levels commonly reported in the literature. However, upon further consideration, we recognize that presenting the actual current density profiles is still valuable and does not compromise the integrity of our analysis. In response to this comment, we have now included a new figure (Figure 5d) in the revised manuscript, which presents the current density profiles recorded during each ED run at different applied voltages (8–16 V). The corresponding discussion has also been added in Section 3.1 to interpret the current density evolution and its relationship with desalination performance. Lines 288-306: This behavior cannot be explained fully by the simplified ion-migration model and was therefore interpreted in conjunction with current density. To further examine the role of current density, the current density during each desalination run was recorded and plotted against time (Figure 5d). The peak current density increased with increasing applied voltage, which is expected from Ohm's law. At 8-12 V, the current density curves remained relatively stable throughout the run, indicating that ion transport proceeded without significant mass‑transfer limitation. At 14 V and 16 V, however, the curves became much steeper, reflecting a more rapid decline in current density as desalination progressed. Notably, although 16 V gave the highest peak current density among all tested voltages, it did not result in a higher desalination rate than 14 V (Figure 5a). This apparent contradiction suggests that the additional current at 16 V did not contribute effectively to salt removal; instead, a considerable fraction of the applied current was consumed by side reactions such as water dissociation at the membrane/solution interfaces. This behavior is a typical manifestation of concentration polarization: once the operation exceeds the limiting current density, further voltage increase enhances parasitic processes rather than ion migration, leading to a decrease in current efficiency and an overall loss of desalination performance. In contrast, at 14 V, the balance between driving force and mass transfer was more favorable, resulting in the highest effective desalination rate among the conditions tested [24,25]. |
||||||||||||||||||||||||||||||||||||||||||||
|
Comments 10: The comparison with previous literature could be strengthened by including a concise table summarizing: feed composition, operating conditions, recovery, purity, energy consumption, and membrane productivity for comparable electrodialysis studies involving amino acid or organic acid separations. |
||||||||||||||||||||||||||||||||||||||||||||
|
Response 10: We appreciate the reviewer’s constructive suggestion regarding the literature comparison. We fully acknowledge that the present study, being primarily focused on process optimization and parameter analysis, may not be perceived as highly novel in terms of fundamental discovery. However, we found that publicly available literature reporting comparable ED studies on amino acid or organic acid separations with complete data sets (feed composition, operating conditions, recovery, purity, energy consumption, and membrane productivity) is still rather limited. Some studies present recovery data but lack purity or energy consumption values, while others report only overall performance without detailed operating conditions. This may be due to the fact that our study, like many similar investigations, emphasizes the effects of operating parameters on process economics and product quality—whereas other works in the field have focused on different aspects such as membrane material development or transport phenomena, making direct quantitative comparison less straightforward. Under the given revision time constraints, we have decided to strengthen the Introduction by providing a more comprehensive review of previous studies and their general trends, rather than constructing a comparative table with incomplete or inconsistent data. We hope this approach still addresses the reviewer’s concern by better situating our work within the existing literature. The revised Introduction now includes a more detailed discussion of earlier ED studies and explicitly identifies the knowledge gaps that our work aims to fill (lines 68-85). “Early studies on ED separation of taurine from Na2SO4 demonstrated the technical feasibility of this approach. Konarev reported that introducing ED into taurine production markedly improved product quality, eliminated energy-intensive operations, and removed poisonous gas emissions [15]. In an early investigation, Zhao et al. achieved a taurine purity of 98.5% and a recovery of 78.1% from a taurine/Na2SO4 mixed solution using ED [16]. More recently, Eliseeva and Kharina comprehensively reviewed electromembrane desalination of amino acid solutions, examining the influence of various mineral cations (Na+, K+, NH4+) and anions (NO3-, SO42-, Cl-) on ion transport and membrane current-voltage characteristics [17]. Studies on phenylalanine-salt systems have further revealed that electroconvection at overlimiting current modes can increase amino acid loss, and that membrane ion-exchange resin content significantly affects separation efficiency [18]. For the taurine/Na2SO4 system, the effects of operating parameters on amino acid loss and mass-transfer behavior under high salt concentrations remain insufficiently understood. Endpoint regulation of the ED process coupled with crystallization for energy consumption control has not been reported, and the specific advantages of ED over crystallization have not been quantitatively evaluated.” |
||||||||||||||||||||||||||||||||||||||||||||
|
Comments 11: The endpoint optimization strategy proposed in Section 3.5 is one of the most interesting outcomes of the study. The authors may consider emphasizing this novelty more strongly in both the Abstract and Conclusions. |
||||||||||||||||||||||||||||||||||||||||||||
|
Response 11: We thank the reviewer for the positive recognition of our work. In response, we have strengthened the description of this contribution in both the Abstract and Conclusions. Line 20-24: “One of the key findings of this work is that the low-salt stage plays a dominant role in process economics. This observation led to a simple endpoint-control strategy. The ED operation is stopped when the Na2SO4 concentration in the dilute compartment drops to about 2 g/L. This avoids prolonged operation under inefficient conditions and reduces ED energy consumption by 16.5%. ” Lines 542-549: “Beyond process optimization, this study provides a practical strategy for process control: using approximately 2 g/L Na2SO4₄ in the dilute compartment as the separation endpoint. Unlike most previous ED studies that focus primarily on parametric optimization, we have quantitatively demonstrated that the low‑salt stage is the dominant factor governing process energy efficiency. Setting the endpoint at 2 g/L Na2SO4 avoided inefficient operation at low salt concentrations and reduced the ED‑unit energy consumption by approximately 16.5%. This endpoint‑control strategy is simple, requires no additional equipment, and can be readily implemented in industrial practice. The estimated specific energy consumption and separation cost were lower by 2.7 kWh/kg taurine and 0.08 USD/kg taurine, respectively, than those of the conventional crystallization route.” |
||||||||||||||||||||||||||||||||||||||||||||
|
Comments 12: Some figure labels, axis fonts, and legends appear relatively small and may be difficult to read after journal formatting. Improving figure readability would enhance presentation quality. |
||||||||||||||||||||||||||||||||||||||||||||
|
Response 12: Agree. We have revised Figures 1, 5, 7, 8, and 10 to provide readers with a clearer and more coherent presentation. |
||||||||||||||||||||||||||||||||||||||||||||
Author Response File:
Author Response.pdf
Reviewer 3 Report
Comments and Suggestions for Authors- Line 45-48: The citations provided (Tomé et al., 2010; Wu et al., 2017) do not support the claims about multi‑step crystallization, mother‑liquor recycling, or increased evaporation/energy/wastewater burdens. These papers address amino‑acid solubility and taurine crystallization behavior, not industrial purification practices. More appropriate references are needed or the statement should be revised.
- Line 63-67: Prior electrodialysis work on taurine is not adequately reviewed. The introduction does not describe what earlier studies found, what limitations existed, or how this work advances beyond them. The discussion in lines 63–67 is too general to establish a clear research gap.
- Line 109: why choose median vs. mean?
- Line 133: how was the activity coefficient calculated?
- Line 155: The description of Na₂SO₄ quantification is unclear. ICP‑MS and conductivity measurements are separate analytical methods, but the manuscript presents them as if they are part of a single procedure. It is not explained how the Na⁺ concentration from ICP‑MS and the conductivity–concentration correlation are combined, or whether they serve as independent checks. This section requires clarification of the analytical workflow.
- Line 161: The description of taurine quantification is unclear. The manuscript does not adequately explain the analytical workflow, the chemical basis of the formaldehyde–NaOH titration, or the rationale behind the purity and recovery equations. The notation (m₁, m₂, W₁) is confusing, and the recovery formula lacks a clear mass-balance justification. Additionally, no validation of the titration method is provided. This section requires clearer explanation and methodological transparency.
- Line 180: The membrane‑replacement cost equation lacks unit consistency and does not clearly explain each parameter. The inclusion of “×2” and “0.68” is not justified, and the conversion from Na₂SO₄ productivity to taurine cost is not explained.
- Line 195: The description of the COMSOL ion‑flux results is incomplete and difficult to follow. The manuscript does not clearly define the modeling domain, membrane thickness, boundary-layer regions, or flux sign conventions. The explanation of the flux profiles is overly simplistic and does not relate the simulated fluxes to the experimentally measured desalination rates. Additionally, only Na⁺ flux is shown, despite the study’s emphasis on taurine retention. Overall, the modeling section requires clearer physical interpretation and stronger linkage to the experimental results.
- Line 203: The authors attribute the reduced desalination rate at 16 V to operation above the limiting current density. The manuscript does not report the actual current density values during the desalination experiments at 8–16 V. Quantitative current data for the desalination runs are needed to support this interpretation.
- Line 215: at what condition was the average current and loss measured in Figure 7?
- Line 238: The membrane cost values in Table 4 are not traceable to the underlying assumptions. The manuscript does not show how membrane area or separation time were determined at each voltage, nor how these were converted into USD/kg taurine. Although the throughput assumptions (62.5 kg taurine/h and 42.5 kg Na₂SO₄/h) are reasonable for an illustrative cost basis, they are not linked to actual ED performance across voltages. As a result, the cost model is too simplified to support a strong conclusion that 14 V is the optimal operating point.
- Line 285: The claim that the desalination rate drops sharply below ~6 g/L Na₂SO₄ is not supported by the data. Neither the experimental curves nor the transient simulations show a clear transition at this concentration, and no quantitative rate analysis is provided. The origin of the 6 g/L threshold should be clarified or justified with explicit evidence
- Line 358: The comparison in Table 5 is interesting but lacks methodological transparency. The basis for the crystallization benchmark values is not explained, and the ED cost and energy values rely on simplified assumptions presented earlier. The claim of zero waste for ED is overstated, and the energy comparison does not show how steam and electrical loads were calculated or whether ED energy includes balance‑of‑plant requirements such as pumping, cooling, and other auxiliary operating costs. As a result, the conclusion that ED offers a clear cost and efficiency advantage over crystallization is not fully supported by the provided data.
- The study provides useful laboratory data, but it does not convincingly demonstrate the practical feasibility of electrodialysis for taurine purification. Key performance claims—limiting‑current behavior, desalination‑rate trends, endpoint selection, and system robustness—are not supported by quantitative flux or current data. The cost analysis relies on simplified and partially undocumented assumptions, and it is unclear whether ED energy and operating costs include balance‑of‑plant requirements such as pumping and cooling. Because the process was tested only on simulated mother liquor and short runs, the conclusions about efficiency and economic advantage over crystallization are premature.
Author Response
|
Response to Reviewer 3 Comments
|
||
|
Summary |
|
|
|
Thank you for your thoughtful and thorough review. Your constructive comments have made us deeply aware of the shortcomings in our manuscript. After carefully studying all the comments, we have made appropriate revisions to the content. Specifically, we have supplemented unclear methodological aspects with additional explanations, and revised or removed statements that lacked sufficient experimental or literature support. We believe these revisions have made the logic of the manuscript more rigorous, the arguments more solid, and the overall scientific quality and academic value significantly improved. Below, we provide point‑by‑point responses to each comment. The revisions are marked in red in the revised manuscript, and the corresponding line numbers are provided for your convenience. |
||
|
Point-by-point response to Comments and Suggestions for Authors |
||
|
Comments 1: Line 45-48: The citations provided (Tomé et al., 2010; Wu et al., 2017) do not support the claims about multi step crystallization, mother liquor recycling, or increased evaporation/energy/wastewater burdens. These papers address amino acid solubility and taurine crystallization behavior, not industrial purification practices. More appropriate references are needed or the statement should be revised. |
||
|
Response 1: Thank you for pointing this out. We agree with this comment. Therefore, we have revised the original text, removed the inappropriate references, and the modifications are located on lines 46–50. “These processes separate taurine from Na2SO4 primarily on the basis of differences in solubility and its temperature dependence. However, as reported in studies on amino acid solubility and crystallization behavior, the presence of inorganic salts can significantly influence the solubility and nucleation kinetics of amino acids through salting-in/out effects and co-crystallization, which may compromise separation performance in practical operations [5,6]. In industrial practice, multiple crystallization or recrystallization steps are often required to ensure product purity, while mother liquor recycling is used to improve the overall recovery [7]. ” |
||
|
Comments 2: Line 63-67: Prior electrodialysis work on taurine is not adequately reviewed. The introduction does not describe what earlier studies found, what limitations existed, or how this work advances beyond them. The discussion in lines 63-67 is too general to establish a clear research gap. |
||
|
Response 2: Agree. The revisions have been made on lines 68-85 of the revised manuscript. We have deepened the analysis of previous studies and identified the research gaps, thereby emphasizing the value of our work. “ED may therefore reduce the number of phase-change steps required in conventional crystallization, thereby lowering the separation energy and improving taurine recovery. Early studies on ED separation of taurine from Na2SO4 demonstrated the technical feasibility of this approach. Konarev reported that introducing ED into taurine production markedly improved product quality, eliminated energy-intensive operations, and removed poisonous gas emissions [15]. In an early investigation, Zhao et al. achieved a taurine purity of 98.5% and a recovery of 78.1% from a taurine/Na2SO4 mixed solution using ED [16]. More recently, Eliseeva and Kharina comprehensively reviewed electromembrane desalination of amino acid solutions, examining the influence of various mineral cations (Na+, K+, NH4+) and anions (NO3-, SO42-, Cl-) on ion transport and membrane current–voltage characteristics [17]. Studies on phenylalanine–salt systems have further revealed that electroconvection at overlimiting current modes can increase amino acid loss, and that membrane ion-exchange resin content significantly affects separation efficiency [18]. Studies on ED applied to the taurine/Na2SO4 system have been primarily limited to feasibility validation. The effects of operating parameters on mass-transfer behavior under high salt concentrations remain insufficiently understood. Endpoint regulation of the ED process coupled with crystallization for energy consumption control has not been reported, and the specific advantages of ED over crystallization have not been quantitatively evaluated. In this study, conventional ED was used to desalt a binary simulated taurine/Na2SO4 mother liquor. In this study, conventional ED was used to desalt a binary simulated taurine/Na2SO4 mother liquor.” |
||
|
Comments 3: why choose median vs. mean? |
||
|
Response 3: We thank the reviewer for this question. The choice of statistical measure was based on the nature and measurement characteristics of each performance indicator, rather than applying a uniform rule to all datasets. For the desalination rate, the median was chosen. Under identical operating conditions, the conductivity readings in the dilute compartment exhibited fluctuations toward the end of each run, particularly when the salt concentration became low and concentration polarization began to develop. Under such conditions, the mean value would be sensitive to these endpoint deviations and would not accurately reflect the overall desalination trend, often resulting in less smooth and less representative curves. The median, being less influenced by extreme fluctuations, provides a more stable and reliable description of the desalination profile. For taurine purity and recovery, the mean was used. These values were obtained by titration, which gives a single final result per run rather than a time‑dependent profile. The titration‑based determination is inherently precise and reproducible, and averaging the results from triplicate runs provides a more accurate estimate of the true value. For energy consumption and membrane productivity, the mean was also adopted. These indicators are calculated from integrated quantities (total charge passed, total salt removed, and total operation time) rather than from instantaneous readings. The integrated nature of these measurements makes them less susceptible to transient fluctuations, and the mean value across replicate runs is therefore more meaningful and more representative for practical reference. In summary, the median was used for the time-dependent desalination profiles to ensure curve stability and representativeness, while the mean was used for the endpoint-based performance indicators (purity, recovery, energy consumption, and membrane productivity) to provide accurate and reliable average values. This distinction has been clarified in the revised manuscript on lines 140–144. “The desalination rate is reported as the median value of triplicate runs because the conductivity readings exhibited relatively large fluctuations toward the end of the experiments, particularly when the salt concentration became low, and the use of the mean would have introduced bias due to these endpoint deviations. The median, being less sensitive to extreme fluctuations, provides a more representative description of the desalination trend.” |
||
|
Comments 4: Line 133: how was the activity coefficient calculated? |
||
|
Response 4: We thank the reviewer for this question. In the Nernst-Planck equation used in our COMSOL simulation, the term dlnγᵢ/dx was included for completeness of the theoretical formulation. However, because our model was developed primarily as a qualitative interpretation tool to visualize ion‑transport trends rather than as a predictive simulation, we did not explicitly calculate the activity coefficients. Instead, we simplified the simulation by assuming ideal solution behavior (i.e., γᵢ = 1) and neglecting the activity‑coefficient gradient term in the model implementation. This simplification is common in COMSOL-based electrodialysis modeling studies when the focus is on qualitative trend analysis rather than precise quantitative prediction, particularly for systems with moderate ionic strengths where the deviation from ideality is relatively small. We have now added a brief statement in the revised manuscript (Section 2.4.1, lines 179-183) to clarify this point. “In the present model, the activity‑coefficient term in Equation 1 was retained only for completeness of the theoretical framework. For practical implementation, ideal solution behavior was assumed (γi=1) and the activity‑coefficient gradient was neglected. This simplification is acceptable for qualitative trend analysis, which is the primary purpose of the simulation in this study.” |
||
|
Comments 5: Line 155: The description of Na₂SO₄ quantification is unclear. ICP‑MS and conductivity measurements are separate analytical methods, but the manuscript presents them as if they are part of a single procedure. It is not explained how the Na⁺ concentration from ICP‑MS and the conductivity–concentration correlation are combined, or whether they serve as independent checks. This section requires clarification of the analytical workflow. |
||
|
Response 5: Thanks for this comment. We apologize for the lack of clarity in our original description. The analytical workflow is as follows. To establish the conductivity-concentration correlation, a series of Na2SO4 standard solutions with known concentrations was first prepared. The Na+ concentration of each standard solution was accurately determined by ICP-MS, and the corresponding Na2SO4 concentration was then calculated from the Na+ content. The conductivity of each standard solution was simultaneously measured using a calibrated conductivity meter. A regression equation was then fitted between the measured conductivity and the calculated Na2SO4 concentration, as presented in Equation 3. In subsequent experiments, only the conductivity of the solution was measured. The Na2SO4 concentration was then read directly from the established calibration curve without repeating the ICP-MS measurement for every sample. In other words, ICP-MS was used as a "calibration tool" to establish the relationship between conductivity and Na2SO4 concentration, while the conductivity meter served as the "routine analytical instrument" for measuring salt concentration during the ED runs. The desalination profiles in the Results section are therefore presented as salt concentration versus time curves, which were converted from the measured conductivity data using Equation 3. We have revised the description in Section 2.5 at lines 221-231. “To quantify the Na2SO4 concentration, a calibration curve was first established. A series of Na2SO4 standard solutions was prepared, and the Na+ concentration of each solution was accurately determined by ICP-MS. The corresponding Na2SO4 concentration was then calculated from the Na+ content. The conductivity of each standard solution was also measured using a calibrated conductivity meter. A regression equation was fitted between the measured conductivity and the Na2SO4 concentration, as shown in equation 3 (R2 = 0.99): (3) where C (g/L) is the Na2SO4 concentration and σ (mS/cm) the conductivity. In subsequent ED experiments, the Na2SO4 concentration was determined from the measured conductivity using this calibration curve, without repeating ICP‑MS analysis for each sample.” |
||
|
Comments 6: Line 161: The description of taurine quantification is unclear. The manuscript does not adequately explain the analytical workflow, the chemical basis of the formaldehyde–NaOH titration, or the rationale behind the purity and recovery equations. The notation (m₁, m₂, W₁) is confusing, and the recovery formula lacks a clear mass-balance justification. Additionally, no validation of the titration method is provided. This section requires clearer explanation and methodological transparency. |
||
|
Response 6: Thanks for this suggestion. In response, we have revised the description of the taurine titration method to improve methodological transparency. The chemical principle of the formaldehyde-NaOH titration has been added, and the mass-balance basis for the purity and recovery equations has been clarified. We have also included method validation data: the average recovery (100.2%, RSD = 0.42%), and the relative standard deviation (< 0.5%). These validation results confirm that the titration method is reliable and suitable for the quantitative analysis of taurine in this study. The corresponding revisions have been made in Section 2.5 At lines 233-237: “Taurine is a zwitterionic amino acid and cannot be directly titrated with a strong base. When formaldehyde is added, it reacts with the amino group (-NH2) of taurine to form N-methylol derivatives, which eliminates the basicity of the amino group and releases protons. This allows the sulfonic acid group (-SO3H) to be titrated with standardized NaOH solution [22].” And line 242-250: “m0 (g) is the sample mass (0.2 g); m1 (g) is the initial mass of taurine in the dilute compartment; m2 (g) is the total solute mass recovered from the concentrate compartment; and W1 (%) is the taurine mass fraction in the concentrate compartment determined by titration. The recovery (X, %) is calculated as the fraction of taurine retained in the dilute compartment. The method was validated under the experimental conditions. The average recovery was 100.2% (RSD=0.42%, n=3), and the RSD for repeated measurements was below 0.5%. These results confirm that the titration method is reliable and suitable for taurine quantification in this study.” |
||
|
Comments 7: Line 180: The membrane replacement cost equation lacks unit consistency and does not clearly explain each parameter. The inclusion of “×2” and “0.68” is not justified, and the conversion from Na₂SO₄ productivity to taurine cost is not explained. |
||
|
Response 7: We thank the reviewer for this comment. We acknowledge that the original formula contained an error: the factor 0.68 should have been placed in the numerator rather than the denominator, as it represents the mass ratio of Na2SO4 to taurine in the feed (taurine: Na2SO4 = 1:0.68), and is used to convert the Na2SO4‑based membrane productivity to a taurine‑based cost. The formula has now been corrected in equation 9. MC = (220×2×0.68)/(5×8000×MP) (9) The meaning of each parameter is as follows: 220 (USD/m²): unit price of a single membrane sheet, based on supplier quotation. each cell pair contains two membranes (one cation‑exchange membrane and one anion‑exchange membrane). 0.68: mass ratio of Na2SO4 to taurine in the feed, used to convert membrane productivity from a Na2SO4 basis to a taurine basis. 5 (years): assumed membrane service life. 8000 (h/year): assumed annual operating time. MP (kg Na2SO4/(m²·h)): membrane productivity. We have revised the formula and added a clear explanation of each parameter and the unit conversion in the revised manuscript at lines 264-268. “where MP is the membrane productivity [kg Na2SO4/(m2·h)], and “8000” is the assumed annual operating time (h), “0.68” represents the mass ratio of Na2SO4 to taurine in the feed (taurine: Na2SO4 = 1:0.68), The factor "×2" accounts for the fact that each cell pair in the electrodialysis stack consists of two membranes: one cation-exchange membrane and one anion-exchange membrane. ” |
||
|
Comments 8: Line 195: The description of the COMSOL ion flux results is incomplete and difficult to follow. The manuscript does not clearly define the modeling domain, membrane thickness, boundary-layer regions, or flux sign conventions. The explanation of the flux profiles is overly simplistic and does not relate the simulated fluxes to the experimentally measured desalination rates. Additionally, only Na⁺ flux is shown, despite the study’s emphasis on taurine retention. Overall, the modeling section requires clearer physical interpretation and stronger linkage to the experimental results. |
||
|
Response 8: Thanks for this constructive comment. We fully agree that the original description of the COMSOL simulation was insufficiently clear, and we have revised this section substantially in response. First, we would like to clarify that the model was developed as a qualitative visualization tool to support the interpretation of experimental trends, rather than as a quantitatively predictive simulation. As noted in our response to Reviewer 2, our group specializes in experimental membrane separation rather than numerical modeling, and the model was intended to provide a visual representation of the ion‑transport behavior predicted by the Nernst-Planck framework under different operating conditions. We have now explicitly stated this in Section 2.4. Regarding the specific issues raised: 1. Modeling domain: The computational domain is indicated in Figure 3b (the region enclosed by the dashed rectangle). We have added a clearer description in the revised text to explain that this domain covers one complete ED unit cell, including one cation-exchange membrane, one anion-exchange membrane, the dilute channel between them, and the adjacent concentrate channels. 2. Membrane thickness and boundary layers: The membrane thickness is listed in Table 2 (0.1 mm). 3. Flux sign convention: The positive flux direction is defined as the direction from the dilute compartment toward the concentrate compartment (from left to right in the model geometry shown in Figure 3b). This convention has been added to the revised manuscript. 4. Linkage between simulated flux and experimental desalination rate: We agree that this linkage was not adequately explained. In the revised manuscript, we have explicitly stated that the simulated Na⁺ flux profiles are used to illustrate the relative trends in ion transport (e.g., the increase in flux with increasing voltage or concentration), which are consistent with the observed experimental desalination rates. The simulation outputs are not intended to provide quantitative predictions of the absolute desalination rate, but rather to support the mechanistic interpretation of the experimental observations. 5. Taurine flux: We acknowledge that only Na⁺ flux was presented in the original submission, despite the study's emphasis on taurine retention. The reason is that the experimental desalination rate is based on Na⁺ (or Na2SO4) removal, which is the primary focus of the ED process. Taurine retention was confirmed by the high purity and recovery values obtained from titration analysis, and the simulation was designed to explain the salt removal behavior rather than taurine transport. To address this point, we have added a brief statement in the revised manuscript acknowledging that SO₄²⁻ transport is coupled with Na⁺ transport to maintain electroneutrality, and that the Na⁺ flux therefore provides a representative indication of salt migration in the system. We believe these revisions substantially improve the clarity and transparency of the modeling section. The corresponding modifications have been made in Section 2.4, Section 3.3, and Section 3.3. Section 2.4 lines187-200: “The computational domain of the two-dimensional model is shown in Figure 3b, covering one ED unit cell (one dilute channel flanked by cation- and anion-exchange membranes and adjacent concentrate channels). The boundary layers adjacent to the membrane surfaces are not pre-defined but emerge from the simulation as regions of steep concentration gradients, reflecting the onset of concentration polarization. The positive flux direction is defined as from the dilute to the concentrate side (left to right in Figure 3b). Taurine transport is not explicitly simulated because taurine is predominantly zwitterionic and electrically neutral under the experimental pH conditions, and its retention is confirmed by the high purity and recovery values obtained from titration.” Lines 212-219: “The COMSOL model presented here was developed as a qualitative interpretation tool to visualize the ion-transport behavior predicted by the Nernst–Planck equations under different operating conditions. The model has not been quantitatively validated against experimental data, and its outputs are intended to illustrate the trends observed in the experiments rather than to provide accurate quantitative predictions. Quantitative validation would require detailed inputs such as membrane transport properties, boundary-layer thickness, and concentration-dependent diffusion coefficients which are beyond the scope of the present study.” Section 3.1 lines 275-285: “The simulated Na+ flux profiles in Figure 6 are presented as qualitative illustrations of the effect of applied voltage on ion transport. The nearly flat regions at 0.0004 and 0.0014 m correspond to the ion-exchange membranes, whereas the regions with changing slopes on either side represent the membrane/solution boundary layers. While the simulations show a clear increase in Na+ flux with increasing unit voltage (from 1 to 3 V), consistent with the experimental desalination trends, the absolute flux values should not be interpreted as validated predictions due to the simplified nature of the model and the lack of quantitative calibration against the present experimental system.” Section 3.3 lines 415-419: “The simulation results indicated that the desalination rate increased with initial concentration. As with the voltage simulations, the transient desalination profiles shown in Figure 11 are intended for qualitative interpretation of the concentration effect trends and have not been quantitatively validated against the present experimental data.” |
||
|
Comments 9: Line 203: The authors attribute the reduced desalination rate at 16 V to operation above the limiting current density. The manuscript does not report the actual current density values during the desalination experiments at 8–16 V. Quantitative current data for the desalination runs are needed to support this interpretation. |
||
|
Response 9: Agree. We thank the reviewer for this critical comment. We fully agree that the limiting current density (LCD) measured in Section 2.3 should not be treated as a fixed threshold applicable to the entire desalination process, but rather as a reference guide for selecting the experimental voltage range. First, we have revised Section 2.3 to clarify the role of the limiting current density measurement. As we now state explicitly, the LCD value obtained under constant‑concentration conditions (16.24 mA/cm² at 15.4 V) serves primarily as a practical reference for selecting the appropriate voltage range in the experimental design, rather than as a fixed threshold that applies uniformly throughout the entire batch desalination process. In actual ED runs, the salt concentration in the dilute compartment decreases continuously, and the actual LCD varies accordingly. This dynamic behavior has been clearly stated in the revised manuscript. Second, we have now included a new figure (Figure 5d) in the revised manuscript, which presents the current‑density profiles recorded during each ED run at different applied voltages (8–16 V). These data provide quantitative, experiment‑based evidence for analyzing the current evolution and inferring the occurrence of concentration polarization under dynamic concentration conditions. The discussion of the 16 V behavior is now based on this direct experimental evidence, rather than solely on the LCD measurement. Section 2.3 lines 158-167: “The ilim measured under constant-concentration conditions provides a practical reference for selecting the applied voltage, rather than a fixed threshold that applies uniformly throughout the entire batch desalination process. In actual operation, the dilute‑compartment concentration decreases continuously, and the ilim varies accordingly. Therefore, a current density that exceeds the measured ilim under steady‑state conditions may not necessarily cause concentration polarization when the bulk concentration is high, while a current density below the measured ilim may still cause polarization when the salt concentration becomes low. The actual current‑density evolution during each run is therefore the more relevant indicator for assessing polarization.” Section 3.1 lines 288-306: “This behavior cannot be explained fully by the simplified ion-migration model and was therefore interpreted in conjunction with current density. To further examine the role of current density, the current density during each desalination run was recorded and plotted against time (Figure 5d). The peak current density increased with increasing applied voltage, which is expected from Ohm's law. At 8–12 V, the current density curves remained relatively stable throughout the run, indicating that ion transport proceeded without significant mass‑transfer limitation. At 14 V and 16 V, however, the curves became much steeper, reflecting a more rapid decline in current density as desalination progressed. Notably, although 16 V gave the highest peak current density among all tested voltages, it did not result in a higher desalination rate than 14 V (Figure 5a). This apparent contradiction suggests that the additional current at 16 V did not contribute effectively to salt removal; instead, a considerable fraction of the applied current was consumed by side reactions such as water dissociation at the membrane/solution interfaces. This behavior is a typical manifestation of concentration polarization: once the operation exceeds the limiting current density, further voltage increase enhances parasitic processes rather than ion migration, leading to a decrease in current efficiency and an overall loss of desalination performance. In contrast, at 14 V, the balance between driving force and mass transfer was more favorable, resulting in the highest effective desalination rate among the conditions tested [24,25].” |
||
|
Comments 10: Line 215: at what condition was the average current and loss measured in Figure 7? |
||
|
Response 10: We thank the reviewer for this careful observation. We apologize for omitting this important information in our original submission. The data presented in Figure 7, including the average current and taurine loss, were obtained under the 10 V condition in the voltage optimization experiments. The total duration of this run was 75 minutes. This particular condition was chosen because 10 V is an intermediate voltage level among the tested range (8–16 V), and the corresponding separation time is neither too short nor too long, making it suitable for illustrating the relationship between taurine loss, operating time, and current. We acknowledge that this information was not clearly stated in the original manuscript. In response, we have now added a brief description of the measurement conditions in both the figure caption and the main text (Section 3.1, lines 319-321). We hope this clarifies the origin of the data presented in Figure 7. “The data in Figure 7 were collected from the run at 10 V, which was selected as an intermediate voltage level among the tested range.” “Figure 7. Relationship between taurine loss, operating time, and current (data obtained at 10 V).” |
||
|
Comments 11: Line 215: The membrane cost values in Table 4 are not traceable to the underlying assumptions. The manuscript does not show how membrane area or separation time were determined at each voltage, nor how these were converted into USD/kg taurine. Although the throughput assumptions (62.5 kg taurine/h and 42.5 kg Na₂SO₄/h) are reasonable for an illustrative cost basis, they are not linked to actual ED performance across voltages. As a result, the cost model is too simplified to support a strong conclusion that 14 V is the optimal operating point. |
||
|
Response 11: We thank the reviewer for this comment. The membrane area at each voltage was determined from the experimentally measured MP values (Equation 8), and the membrane cost was then calculated using Equation (9). Thus, the membrane cost is directly linked to the actual ED performance at each voltage. We agree that the cost model is simplified, covering only electricity and membrane replacement. Accordingly, we have revised the conclusion in Section 3.1: instead of stating that 14 V is the overall optimum, we now specify that it gives the lowest combined electricity and membrane cost among the tested voltages within the defined accounting boundary. A statement acknowledging the simplified nature of the cost analysis has also been added. Section 3.1, line366-370: “Based on the separation performance and the estimated electricity and membrane replacement costs, 14 V gave the lowest combined cost among the tested voltages within the defined accounting boundary. This cost estimation considers only electricity and membrane replacement, and does not include other capital or operating costs.” |
||
|
Comments 12: Line 238: The claim that the desalination rate drops sharply below ~6 g/L Na2SO4 is not supported by the data. Neither the experimental curves nor the transient simulations show a clear transition at this concentration, and no quantitative rate analysis is provided. The origin of the 6 g/L threshold should be clarified or justified with explicit evidence. |
||
|
Response 12: This comment is well taken. The ~6 g/L threshold was an empirical observation without rigorous justification and has been removed. The qualitative statement that the desalination rate decreases at low salt concentrations is retained. The revision is in Section 3.3 (line 423). “Comparison of Figures 5a, 8a, and 10a shows that desalination rate remained relatively stable at high salinity but decreased at low salt concentrations.” |
||
|
Comments 13: Line 285: The comparison in Table 5 is interesting but lacks methodological transparency. The basis for the crystallization benchmark values is not explained, and the ED cost and energy values rely on simplified assumptions presented earlier. The claim of zero waste for ED is overstated, and the energy comparison does not show how steam and electrical loads were calculated or whether ED energy includes balance of plant requirements such as pumping, cooling, and other auxiliary operating costs. As a result, the conclusion that ED offers a clear cost and efficiency advantage over crystallization is not fully supported by the provided data. |
||
|
Response 13: The crystallization benchmark data were provided by a collaborator based on an industrial process package for taurine production via the ethylene oxide route and calculated independently by our group. The ED electrical energy (0.56 kWh/kg) was directly measured from the ED runs. The evaporation energy (7.02 kWh/kg) was estimated from the latent heat of water, assuming 100% thermal efficiency with steam as the heat source. The crystallization electrical energy (cooling) was estimated similarly with 100% efficiency. Auxiliary loads (pumping) were excluded from both routes, as they were assumed to be comparable and outside the defined accounting boundary. The “zero waste” value refers specifically to no direct discharge of salt-containing mother liquor under the complete- evaporation assumption; it does not imply zero liquid discharge in general. We have added footnotes to Table 5 and revised the discussion to state that the ED route shows potential for lower energy and cost within this specific boundary, rather than claiming a general advantage. The revisions are in Section 3.6 Lines 501-505: “A crystallization data from an industrial process package and calculated by the authors. ED total energy = ED electrical energy (0.56 kWh/kg) + evaporation energy (7.02 kWh/kg). Evaporation energy was estimated from water latent heat assuming 100% thermal efficiency. Auxiliary energies are not included.” Lines 510-511: “1 “0” waste refers to no direct discharge of salt‑containing mother liquor under the defined closed-loop assumption and does not imply zero liquid discharge.” |
||
Author Response File:
Author Response.pdf
Round 2
Reviewer 1 Report
Comments and Suggestions for AuthorsThe revised form of this manuscript is suitable for publication in Membranes.
Only two things should be corrected in the manuscript:
i) The membrane resistance unit should be added to Table 1,
ii) The standard deviation of the temperature should be added to Table 3.
Author Response
|
Comments 1: The membrane resistance unit should be added to Table 1, |
|
Response 1: We thank the reviewer for catching this omission. The membrane resistance unit has been added to Table 1 and is highlighted in red.
|
|
Comments 2: The standard deviation of the temperature should be added to Table 3 |
|
Response 2: We thank the reviewer for this suggestion. The standard deviations of the temperature measurements have been added to Table 3 (mean ± SD, n = 3). The standard deviations range from 0.1 to 0.3 °C, confirming that the observed temperature differences are within experimental uncertainty. The corresponding revision has been highlighted in red.
|
Reviewer 3 Report
Comments and Suggestions for Authors- Line 107: is it Ti-coated Pt or Pt coated Ti?
- Table 1: please explain the meaning of "AC" and "CC"
- Line 319: High voltage, higher energy consumption. Could another contribution from overpotential on electrode kinetic and ohmic?
Author Response
|
Point-by-point response to Comments and Suggestions for Authors |
|
Comments 1: Line 107: is it Ti-coated Pt or Pt coated Ti? |
|
Response 1: We thank the reviewer for this specific comment. The response is highlighted in red. Line107 “The electrode material is Ti/Pt (titanium‑coated platinum).”
|
|
Comments 2: Table 1: please explain the meaning of "AC" and "CC" |
|
Response 2: We thank the reviewer for this question. In Table 1, "AC" and "CC" are the commercial designations assigned by the membrane manufacturer (Shanghai Sanji New Material Co., Ltd.) to their anion-exchange and cation-exchange membranes, respectively. We have revised the related description in Table 1 to clarify this. The modification has been highlighted in red.
|
|
Comments 3: Line 319: High voltage, higher energy consumption. Could another contribution from overpotential on electrode kinetic and ohmic? |
|
Response 3: We agree with the reviewer that, in addition to Joule heating of the solution and membrane resistance, electrode overpotential and ohmic losses at the electrode/solution interface may also contribute to the increased energy consumption at higher voltages. The observed temperature rise was relatively small, suggesting that the additional energy was likely dissipated through these electrochemical losses rather than as sensible heat. We have added a brief statement to this effect in the revised discussion. |
Lines 358-363: “A portion of the additional energy at higher voltages may also be dissipated through electrode overpotential and ohmic losses at the electrode/solution interface [27], as well as through water dissociation associated with concentration polarization. The dominant factor governing the voltage-dependence of energy consumption was therefore the trade-off between increased driving force and reduced current efficiency.”